Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Low Temp Phys ; 193: 886-892, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38515616

RESUMEN

Microwave SQUID multiplexing is a promising technique for multiplexing large arrays of transition edge sensors. A major bottleneck in the development and distribution of microwave SQUID multiplexer chips occurs in the time-intensive design testing and quality assurance stages. To obtain useful RF measurements, these devices must be cooled to temperatures below 500 mK. The need for a more efficient system to screen microwave multiplexer chips has grown as the number of chips requested by collaborators per year reaches into the hundreds. We have therefore assembled a test bed for microwave SQUID circuits, which decreases screening time for four 32-channel chips from 24 h in an adiabatic demagnetization refrigerator to approximately 5 h in a helium dip probe containing a closed cycle 3He sorption refrigerator. We discuss defining characteristics of these microwave circuits and the challenges of establishing an efficient testing setup for them.

2.
Rev Sci Instrum ; 83(9): 093113, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23020368

RESUMEN

Improvements in superconductor device fabrication, detector hybridization techniques, and superconducting quantum interference device readout have made square-centimeter-sized arrays of gamma-ray microcalorimeters, based on transition-edge sensors (TESs), possible. At these collecting areas, gamma microcalorimeters can utilize their unprecedented energy resolution to perform spectroscopy in a number of applications that are limited by closely-spaced spectral peaks, for example, the nondestructive analysis of nuclear materials. We have built a 256 pixel spectrometer with an average full-width-at-half-maximum energy resolution of 53 eV at 97 keV, a useable dynamic range above 400 keV, and a collecting area of 5 cm(2). We have demonstrated multiplexed readout of the full 256 pixel array with 236 of the pixels (91%) giving spectroscopic data. This is the largest multiplexed array of TES microcalorimeters to date. This paper will review the spectrometer, highlighting the instrument design, detector fabrication, readout, operation of the instrument, and data processing. Further, we describe the characterization and performance of the newest 256 pixel array.

3.
Phys Rev Lett ; 62(22): 2604-2607, 1989 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-10040034
4.
Phys Rev Lett ; 58(8): 804-807, 1987 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-10035041
5.
Phys Rev B Condens Matter ; 33(9): 6106-6122, 1986 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-9939158
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA