Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Intervalo de año de publicación
1.
Acc Chem Res ; 57(9): 1372-1383, 2024 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-38590049

RESUMEN

The COVID-19 pandemic further demonstrated the need for usable, reliable, and cost-effective point-of-care diagnostics that can be broadly deployed, ideally for self-testing at home. Antigen tests using more-detectable reporter labels (usually at the cost of reader complexity) achieve better diagnostic sensitivity, supporting the value of higher-analytical-sensitivity reporter technologies in lateral flow.We developed a new approach to simple, inexpensive lateral flow assays (LFAs) of great sensitivity, based on the glow stick peroxyoxalate chemistry widely used in emergency settings and in children's toys. At the peak of the COVID-19 pandemic, we had the opportunity to participate in the pandemic-driven NIH Rapid Acceleration of Diagnostics (RADx) initiative aiming to develop a deployable lateral flow diagnostic for SARS-CoV-2 nucleoprotein based on our novel glow stick-inspired light-emitting reporter technology. During this project, we screened more than 250 antibody pairs for analytical sensitivity and specificity directly in LFA format, using recombinant nucleoprotein and then gamma-irradiated virions spiked into negative nasal swab extracts. Membranes and other LFA materials and swabs and extraction reagent components also were screened and selected. Optimization of conjugate preparation and spraying as well as pretreatment/conditioning of the sample pad led to the final optimized LFA strip. Technology development also included optimization of excitation liquid enclosed in disposable droppers, design of a custom cartridge and smartphone-based reader, and app development, even a prototype reader usable with any mobile phone. Excellent preclinical performance was first demonstrated with contrived samples and then with leftover clinical samples. Moving beyond traditional academic focus areas, we were able to establish a quality management system (QMS), produce large numbers of customized LFA cassettes by contract injection molding, build in-house facilities to assemble and store thousands of complete tests for verification and validation and usability studies, and source kitting/packaging services and quality standard reagents and build partnerships for clinical translation, regulatory guidance, scale up, and market deployment. We were not able to bring this early stage technology to the point of commercialization within the limited time and resources available, but we did achieve strong proof-of-concept and advance translational aspects of the platform including initial high-performance LFAs, reading by the iPhone app using only a $2 plastic dark box with no lens, and convenient, usable excitation liquid packaging in droppers manufacturable in very large numbers.In this Account, we aim to provide a concise overview of our 18-month sprint toward the practical development of a deployable antigen lateral flow assay under pandemic conditions and the challenges and successes experienced by our team. We highlight what it takes to coach a technically savvy but commercially inexperienced academic team through the accelerated translation of an early stage technology into a useful product. Finally, we provide a guided tutorial and workflow to empower others interested in the rapid development of translatable LFAs.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , COVID-19/virología , Humanos , SARS-CoV-2/aislamiento & purificación , Pruebas en el Punto de Atención , Prueba Serológica para COVID-19/métodos , Fosfoproteínas/análisis , Fosfoproteínas/metabolismo , Proteínas de la Nucleocápside de Coronavirus/análisis , Prueba de COVID-19/métodos
2.
Analyst ; 149(5): 1665, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38348476

RESUMEN

Correction for 'Smartphone-read phage lateral flow assay for point-of-care detection of infection' by Maede Chabi, et al., Analyst, 2023, 148, 839-848, https://doi.org/10.1039/D2AN01499H.

3.
Aesthet Surg J ; 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38913383

RESUMEN

BACKGROUND: A delayed seroma around breast implants is the most common clinical presentation of BIA-ALCL. However, most seromas are due to benign causes. Therefore, it is essential to distinguish benign seromas from seromas due to BIA-ALCL. In a prior study mean concentrations of IL-9, IL-10 and IL-13 were found to be significantly higher in BIA-ALCL than in benign seromas. OBJECTIVES: The aim of this research was to test the ability to detect high concentrations of IL-9 rapidly with a lateral flow assay (LFA). Because we previously reported that a LFA for CD30 detected BIA-ALCL in seromas we compared CD30 and IL-9 LFAs in distinguishing BIA-ALCL from benign seromas. METHODS: Thirty microliter samples of 26 seromas (15 benign, 11 malignant) were tested on in-house prepared strips for IL-9 and CD30. Nanoparticle-conjugated antibodies specific to IL-9 and CD30 were used for detection. IL-9 was analyzed in undiluted samples and CD30 samples were optimized at 1:3 dilution. The dynamic range of detection was determined by spiking recombinant IL-9 into a benign seroma. Image analysis measured intensity of both test line (TL) and control line (CL) and a TL/CL ratio was calculated. IL-9 protein and IL-9 transcription factor PU.1 were stained in BIA-ALCL lines and clinical samples. RESULTS: The IL-9 LFA was reliable in distinguishing BIA-ALCL from benign seromas when the concentration of IL-9 was greater than 10 ng/ml. The CD30 LFA was positive in all 11 malignant cases. In one case with only faint CD30 and IL-10 test lines, the IL-9 LFA was clearly positive. Immunohistochemistry showed IL-9 and its essential transcription factor PU.1 were present in tumor cells in BIA-ALCL lines and clinical samples. CONCLUSIONS: IL-9 is a tumor cell biomarker of BIA-ALCL that can be detected by lateral flow assay and immunohistochemistry. Concentrations of IL-9 greater than 10 ng/ml reliably distinguished BIA-ALCL from benign seromas. Moreover, IL-9 LFA could detect BIA-ALCL when CD30 LFA was not definitive and IL-10 was of low concentration with a faint IL-10 TL, suggesting a multiplex LFA including IL-9, CD30 and IL-10 might be more effective in detecting BIA-ALCL in selected cases.

4.
J Chromatogr A ; 1730: 465114, 2024 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-38964160

RESUMEN

Protein chromatography is the dominant method of purification of biopharmaceuticals. Although all practical chromatography involves competitive absorption and separation of M. species, competitive protein absorption has remained inadequately understood. We previously introduced the measurement of equilibrium protein adsorption isotherms with all intensive variables held constant, including competitor concentration. In this work, we introduce isocratic chromatographic retention measurements of dynamic protein adsorption in the presence of a constant concentration of a competitor protein. These measurements are achieved by establishing a dynamic equilibrium with a constant concentration of competitor (insulin) in the mobile phase flowing through an ion exchange adsorbent column and following the behavior of a test protein (α-lactalbumin) injected into this environment. We observed decreased retention times for α-lactalbumin in presence of the competitor. The presence of competitor also reduces the heterogeneity of the sites available for adsorption of the test protein. This investigation provides an approach to fundamental understanding of competitive dynamics of multicomponent protein chromatography.


Asunto(s)
Insulina , Lactalbúmina , Cromatografía por Intercambio Iónico/métodos , Adsorción , Lactalbúmina/química , Lactalbúmina/aislamiento & purificación , Insulina/química , Insulina/aislamiento & purificación , Proteínas/aislamiento & purificación , Proteínas/química , Animales , Bovinos
5.
Commun Eng ; 22023.
Artículo en Inglés | MEDLINE | ID: mdl-38586601

RESUMEN

The COVID-19 pandemic has increased demand for point-of-care (POC) screening tests such as lateral flow assays (LFAs) and highlighted the need for sensitive and cost-effective POC diagnostic platforms. Here, we demonstrate an LFA platform using standard fluorescent nanoparticle reporters in which optical excitation is replaced by chemical excitation using the peroxyoxalate-based chemistry of inexpensive, shelf-stable glowsticks. The one-step chemi-excitation of fluorescent particles produces visible light readable by an unmodified smartphone, enhancing sensitivity while preserving simplicity and cost-effectiveness. Our Glow LFA detected the common model analyte human chorionic gonadotropin with a limit of detection (LoD) of 39 pg/mL-over ten times more sensitive than standard gold nanoparticles using the same antibodies. We also demonstrate its application to the detection of SARS-CoV-2 nucleoprotein at 100 pg/mL in nasal swab extract. Multiple fluorescent dyes can be chemi-excited by a single reagent, allowing for color multiplexing on a single LFA strip with a smartphone camera. The detection of three analytes on a single LFA test line was demonstrated using red, green, and blue fluorescent reporter particles, making glow LFA a promising platform for multiplexed detection.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA