Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Neth Heart J ; 32(3): 125-129, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37615827

RESUMEN

INTRODUCTION: Out-of-hospital cardiac arrest (OHCA) caused by an ST-elevation myocardial infarction (STEMI) is often accompanied by a sudden loss of consciousness that may cause the patient to collapse with resulting head trauma, leading to a suspicion of possible intracranial haemorrhage. To rule out intracranial haemorrhage before emergency percutaneous coronary intervention (PCI), emergency computed tomography (CT) of the head might be useful but also causes a delay in percutaneous STEMI treatment. METHODS: The medical records of all adult patients that presented with OHCA to the emergency department (ED) of the University Medical Centre Utrecht (UMCU), the Netherlands between 16 February 2020 and 16 February 2022 were reviewed. RESULTS: A total of 263 patients presented to the ED with an OHCA; 50 presented with a STEMI requiring emergency PCI. Thirty-nine (78%) patients with a STEMI were immediately referred to the catheterisation laboratory and 11 (22%) STEMI patients underwent a CT scan prior to emergency angiography; in no case was PCI deferred on the basis of the CT findings. The dominant indication for CT of the head was collapse, reported by 10 patients and resulting in a visible traumatic head injury in 7 patients. In none of the patients was intracranial haemorrhage detected. However, there was a delay between presentation to the ED and arrival at the catheterisation laboratory in patients who underwent CT of the head (mean 63 ± 25 min) before emergency PCI compared to patients without a CT scan (mean 37 ± 21 min). CONCLUSION: CT of the head did not result in a diagnosis of intracranial haemorrhage or deferral of PCI but did delay PCI treatment for STEMI in patients presenting with OHCA.

2.
Neth Heart J ; 32(6): 245-253, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38713449

RESUMEN

BACKGROUND: In refractory cardiogenic shock, temporary mechanical support (tMCS) may be crucial for maintaining tissue perfusion and oxygen delivery. tMCS can serve as a bridge-to-decision to assess eligibility for left ventricular assist device (LVAD) implantation or heart transplantation, or as a bridge-to-recovery. ECPELLA is a novel tMCS configuration combining venoarterial extracorporeal membrane oxygenation with Impella. The present study presents the clinical parameters, outcomes, and complications of patients supported with ECPELLA. METHODS: All patients supported with ECPELLA at University Medical Centre Utrecht between December 2020 and August 2023 were included. The primary outcome was 30-day mortality, and secondary outcomes were LVAD implantation/heart transplantation and safety outcomes. RESULTS: Twenty patients with an average age of 51 years, and of whom 70% were males, were included. Causes of cardiogenic shock were acute heart failure (due to acute coronary syndrome, myocarditis, or after cardiac surgery) or chronic heart failure, respectively 70 and 30% of cases. The median duration of ECPELLA support was 164 h (interquartile range 98-210). In 50% of cases, a permanent LVAD was implanted. Cardiac recovery within 30 days was seen in 30% of cases and 30-day mortality rate was 20%. ECPELLA support was associated with major bleeding (40%), haemolysis (25%), vascular complications (30%), kidney failure requiring replacement therapy (50%), and Impella failure requiring extraction (15%). CONCLUSION: ECPELLA can be successfully used as a bridge to LVAD implantation or as a bridge-to-recovery in patients with refractory cardiogenic shock. Despite a significant number of complications, 30-day mortality was lower than observed in previous cohorts.

3.
Neth Heart J ; 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38955979

RESUMEN

BACKGROUND: Mortality rates in patients with cardiogenic shock complicating acute myocardial infarction (AMICS) remain high despite advancements in AMI care. Our study aimed to investigate the impact of prehospital symptom duration on the prognosis of AMICS patients and those receiving mechanical circulatory support (MCS). METHODS AND RESULTS: We conducted a retrospective cohort study with data registered in the Netherlands Heart Registration. A total of 1,363 patients with AMICS who underwent percutaneous coronary intervention between 2017 and 2021 were included. Patients presenting after out-of-hospital cardiac arrest were excluded. Most patients were male (68%), with a median age of 69 years (IQR 61-77), predominantly presenting with ST-elevation myocardial infarction (86%). The overall 30-day mortality was 32%. Longer prehospital symptom duration was associated with a higher 30-day mortality with the following rates: < 3 h, 26%; 3-6 h, 29%; 6-24 h, 36%; ≥ 24 h, 46%; p < 0.001. In a subpopulation of AMICS patients with MCS (n = 332, 24%), symptom duration of > 24 h was associated with significantly higher mortality compared to symptom duration of < 24 h (59% vs 45%, p = 0.029). Multivariate analysis identified > 24 h symptom duration, age and in-hospital cardiac arrest as predictors of 30-day mortality in MCS patients. CONCLUSION: Prolonged prehospital symptom duration was associated with significantly increased 30-day mortality in patients presenting with AMICS. In AMICS patients treated with MCS, a symptom duration of > 24 h was an independent predictor of poor survival. These results emphasise the critical role of early recognition and intervention in the prognosis of AMICS patients.

4.
Catheter Cardiovasc Interv ; 101(3): 505-510, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36651339

RESUMEN

OBJECTIVE: The elevated risk of adverse events following percutaneous coronary intervention in diabetic patients persists with newer-generation DES. The polymer-free amphilimus-eluting stent (PF-AES) possesses characteristics with a potentially enhanced performance in patients with diabetes. Data from the 1-year follow-up period has been previously published. The aim of this subanalysis was to assess long-term performance of two contemporary drug-eluting stents (DES) in a diabetic population. METHODS: In the ReCre8 trial, patients were stratified for diabetes and troponin status, and randomized to implantation of a permanent polymer zotarolimus-eluting stent (PP-ZES) or PF-AES. The primary endpoint was target-lesion failure (TLF), a composite of cardiac death, target-vessel myocardial infarction and target-lesion revascularization. Clinical outcomes between discharge and 3 years follow-up were assessed. RESULTS: A total of 302 patients with diabetes were included in this analysis. After 3 years, TLF occurred in 12.5% of PP-ZES patients versus 10.0% in PF-AES patients (p = 0.46). Similarly, the separate components of TLF were comparable between the two study arms. The secondary composite endpoint of NACE was higher in the PP-ZES arm with 45 cases (29.6%) versus 30 cases (20.0%) in the PF-AES arm (p = 0.036). In the insulin-dependent diabetic population, TLF occurred in 19.1% of PP-ZES patients versus 10.4% of PF-AES patients (p = 0.21). NACE occurred in 40.4% of PP-ZES patients versus 27.1% of PF-AES patients (p = 0.10). CONCLUSIONS: This subanalysis shows that the use of PF-AES results in similar clinical outcomes as compared to PP-ZES, yet some benefits of use of PF-AES in diabetic patients may prevail. Future dedicated trials should confirm these findings.


Asunto(s)
Fármacos Cardiovasculares , Enfermedad de la Arteria Coronaria , Diabetes Mellitus , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/inducido químicamente , Estudios de Seguimiento , Factores de Riesgo , Resultado del Tratamiento , Diabetes Mellitus/diagnóstico , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis , Fármacos Cardiovasculares/efectos adversos
5.
Catheter Cardiovasc Interv ; 99(2): 366-372, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-33811730

RESUMEN

OBJECTIVES: The purpose of this analysis was to compare target-lesion failure (TLF) of a permanent polymer zotarolimus-eluting stent (PP-ZES) versus a polymer-free amphilimus-eluting stent (PF-AES) in diabetics. BACKGROUND: The improvement of outcomes with new-generation drug-eluting stent as seen in the general population is less pronounced among diabetics. The PF-AES introduces an elution-technology with potential enhanced performance in diabetics. METHODS: In this subanalysis of the ReCre8 trial, patients were randomized to either a PP-ZES or PF-AES after stratification for diabetes and troponin status. The primary device-oriented endpoint was TLF, a composite of cardiac death, target-vessel myocardial infarction and target-lesion revascularization. RESULTS: In the ReCre8 trial, 304 (20%) patients were diabetic and 96 (6%) had insulin-dependent diabetes mellitus. There was no statistically significant difference between the two study arms regarding the primary endpoint (PP-ZES 7.2% vs. PF-AES 4.0%; p = .21), although the composite of net adverse clinical events was higher in the PP-ZES arm (15.7 vs. 8.0%; p = .035). Stent thrombosis was low in both groups with no cases in the PP-ZES arm and 1 case in the PF-AES arm (p = .32). Regarding insulin-treated diabetics, TLF was higher in the PP-ZES arm (14.9 vs. 2.1%; p = .022). CONCLUSIONS: Diabetics could potentially benefit from a dedicated stent, releasing sirolimus with a lipophilic carrier (amphilimus-formulation). Future trials should confirm the potential benefit of a PF-AES in this population.


Asunto(s)
Fármacos Cardiovasculares , Enfermedad de la Arteria Coronaria , Diabetes Mellitus , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/inducido químicamente , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiología , Humanos , Intervención Coronaria Percutánea/efectos adversos , Polímeros , Diseño de Prótesis , Stents , Resultado del Tratamiento
6.
Catheter Cardiovasc Interv ; 97(4): E597-E606, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32886869

RESUMEN

OBJECTIVES: To compare the outcomes of transfemoral ACURATE neo (NEO) and Sapien 3 (S3) patients in terms of device success and clinical safety outcomes using a propensity score analysis. BACKGROUND: Differences in clinical outcomes between the latest-generation balloon-expandable S3 and self-expanding NEO in a "real-world transfemoral TAVI population" are still unclear. METHODS: We compared up to 6 months clinical outcomes using a propensity score analysis (inverse probability of treatment weighting [IPTW]) to account for differences in baseline characteristics. RESULTS: A total of 345 patients underwent transfemoral transcatheter aortic valve implantation (TAVI) with either NEO or S3 at two centers in the Netherlands. Composite device success and early safety endpoints were comparable between NEO and S3 (Device success: IPTW-adjusted OR: 0.35 [95% CI: 0.12-1.18], and early safety: IPTW-adjusted OR: 0.51 [95% CI: 0.19-1.38]). Six-months mortality was 5.3 versus 3.6%, stroke was 2.8 versus 3.3%, and pacemaker rate was 6.1 versus 8.6%, respectively with p = NS. Mean aortic gradient was lower in the NEO group (5.72 ± 2.47 vs. 9.05 ± 3.48; p = <.001), with a comparable rate of moderate or severe paravalvular leak (0 versus 2.1%; p = NS). CONCLUSIONS: Device success and clinical safety outcomes were comparable for both valves. Up to 6-months follow-up clinical outcomes and mortality rate remained excellent. Mean aortic gradient was lower after ACURATE neo implantation.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Puntaje de Propensión , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
7.
Circulation ; 139(1): 67-77, 2019 01 02.
Artículo en Inglés | MEDLINE | ID: mdl-30586704

RESUMEN

BACKGROUND: Polymer-free amphilimus-eluting stents (PF-AES) represent a novel elution technology in the current era of drug-eluting stents. The clinical safety and efficacy of PF-AES as compared with latest-generation permanent-polymer zotarolimus-eluting stents (PP-ZES) have not yet been investigated in a large randomized trial. METHODS: In this physician-initiated, prospective, multicenter, randomized, noninferiority trial, an all-comers population requiring percutaneous coronary intervention was enrolled across 3 European sites. Randomization (1:1 ratio) to PP-ZES or PF-AES was performed after stratification for troponin status and diabetes mellitus. In both treatment arms, troponin-positive patients were planned for 12-month dual antiplatelet therapy, whereas troponin-negative patients were planned for 1-month dual antiplatelet therapy. Outcome assessors were blinded to the allocated treatment. The device-oriented primary end point of target-lesion failure was defined as cardiac death, target-vessel myocardial infarction, or target-lesion revascularization at 12-months as analyzed by modified intention-to-treat (80% power, and a 3.5% noninferiority margin). RESULTS: In total, 1502 patients were randomized and 1491 treated with the assigned stent and available for follow-up. The primary end point occurred in 42 (5.6%) of the 744 patients receiving PP-ZES versus 46 (6.2%) of the 747 patients receiving PF-AES. PF-AES were clinically noninferior to PP-ZES (risk difference, 0.5%; upper limit 1-sided 95% confidence interval, 2.6%; Pnoninferiority=0.0086). Cardiac death occurred in 10 (1.3%) versus 10 patients (1.3%; P value for difference, 1.00), target-vessel myocardial infarction occurred in 18 (2.4%) versus 17 patients (2.3%; P value for difference, 0.87), and target-lesion revascularization occurred in 22 (2.9%) versus 20 patients (2.6%; P value for difference, 0.75) for PF-AES as compared with PP-ZES. Overall, definite or probable stent thrombosis occurred in 1.0%. CONCLUSIONS: PF-AES were noninferior to PP-ZES regarding target-lesion failure at 12 months. Findings regarding the secondary end point and prespecified subgroups were generally consistent with that of the primary end point. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02328898.


Asunto(s)
Síndrome Coronario Agudo/terapia , Angina Estable/terapia , Angina Inestable/terapia , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea/instrumentación , Polímeros/química , Sirolimus/análogos & derivados , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/mortalidad , Anciano , Angina Estable/diagnóstico , Angina Estable/mortalidad , Angina Inestable/diagnóstico , Angina Inestable/mortalidad , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/etiología , Europa (Continente) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/mortalidad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Sirolimus/administración & dosificación , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
8.
Circ Res ; 122(2): 310-318, 2018 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-29348252

RESUMEN

The international consortium TACTICS (Transnational Alliance for Regenerative Therapies in Cardiovascular Syndromes) has recently addressed key priorities in the field of cell-based therapy for cardiac repair, identifying the efficacy of translational research as one of the main challenges to ultimately improve the quality of life of patients with ischemic disease. Much of the controversy and confusion surrounding cardiac regenerative therapy stems from insufficient rigor in the conduct of preclinical studies, and there is an increasing recognition of a number of problems that undermine its quality that may contribute to translational failure. Here, we introduce well defined stages for preclinical research, and put forth proposals that should promote more rigorous preclinical work, in an effort to improve its quality and translatability. To augment the utility of preclinical research and its translation, it is necessary to (1) improve the quality of preclinical research, (2) promote collaborative efforts, and (3) enhance the sharing of knowledge and protocols. In particular, confirmatory (stage III) preclinical studies should be considered as a preamble to clinical studies and therefore must adhere to their standards of quality (including internal validity, standardization of protocols, and multicenter design). To increase transparency and minimize bias, these studies should be prospectively registered in an independent, open database. Ultimately, these recommendations should be implemented in the daily routine of investigators and in the policies of institutions, journals, and funding agencies.


Asunto(s)
Enfermedades Cardiovasculares/terapia , Medicina Regenerativa/métodos , Investigación Biomédica Traslacional/métodos , Animales , Enfermedades Cardiovasculares/genética , Enfermedades Cardiovasculares/patología , Humanos , Metaanálisis como Asunto , Medicina Regenerativa/tendencias , Revisiones Sistemáticas como Asunto , Investigación Biomédica Traslacional/tendencias
9.
Ann Emerg Med ; 76(4): 527-541, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32461009

RESUMEN

STUDY OBJECTIVE: Syncope is a presenting symptom in 10% to 20% of patients with pulmonary embolism. We perform a meta-analysis to clarify the prognostic value of syncope on short-term mortality in pulmonary embolism patients and its association with hemodynamic instability. METHODS: PubMed, EMBASE, and the Cochrane Library were searched up until January 7, 2020. Studies reporting inhospital or 30-day mortality of adults with pulmonary embolism with and without syncope were included. Quality of included studies was evaluated with the Quality in Prognosis Studies tool. Meta-analysis was conducted to derive pooled odds ratios (ORs) and risk differences for the relation of syncope with mortality and hemodynamic instability. To study the influence of hemodynamic instability on the association between syncope and mortality, meta-regression was performed. RESULTS: Search and selection resulted in 26 studies, of which 20 were pooled, involving 9,419 of 335,120 patients (3%) with syncope. Syncope was associated with higher mortality (OR 1.82; 95% confidence interval [CI] 1.14 to 2.90; I2 88%; risk difference 4% [95% CI 1% to 8%]) and higher prevalence of hemodynamic instability (OR 4.36; 95% CI 2.27 to 8.37; I2 93%; risk difference 12% [95% CI 7% to 18%]). OR for mortality in patients with pulmonary embolism with syncope versus without it was higher in the presence of a larger difference in hemodynamic instability between groups (coefficient 0.05; 95% CI 0.01 to 0.09). CONCLUSION: The association between syncope and short-term mortality in patients with pulmonary embolism is explained by a difference in hemodynamic instability. This emphasizes the importance of risk stratification by hemodynamic status in pulmonary embolism patients with and without syncope.


Asunto(s)
Mortalidad , Pronóstico , Embolia Pulmonar/complicaciones , Síncope/diagnóstico , Humanos , Oportunidad Relativa , Embolia Pulmonar/mortalidad , Medición de Riesgo/métodos , Medición de Riesgo/normas , Síncope/etiología , Síncope/mortalidad
10.
Int J Mol Sci ; 21(17)2020 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-32887275

RESUMEN

Atherosclerosis is the underlying pathology in a major part of cardiovascular disease, the leading cause of mortality in developed countries. The infiltration of monocytes into the vessel walls of large arteries is a key denominator of atherogenesis, making monocytes accountable for the development of atherosclerosis. With the development of high-throughput transcriptome profiling platforms and cytometric methods for circulating cells, it is now feasible to study in-depth the predicted functional change of circulating monocytes reflected by changes of gene expression in certain pathways and correlate the changes to disease outcome. Neuroimmune guidance cues comprise a group of circulating- and cell membrane-associated signaling proteins that are progressively involved in monocyte functions. Here, we employed the CIRCULATING CELLS study cohort to classify cardiovascular disease patients and healthy individuals in relation to their expression of neuroimmune guidance cues in circulating monocytes. To cope with the complexity of human datasets featured by noisy data, nonlinearity and multidimensionality, we assessed various machine-learning methods. Of these, the linear discriminant analysis, Naïve Bayesian model and stochastic gradient boost model yielded perfect or near-perfect sensibility and specificity and revealed that expression levels of the neuroimmune guidance cues SEMA6B, SEMA6D and EPHA2 in circulating monocytes were of predictive values for cardiovascular disease outcome.


Asunto(s)
Biomarcadores/sangre , Enfermedades Cardiovasculares/diagnóstico , Efrinas/sangre , Aprendizaje Automático , Monocitos/metabolismo , Netrina-1/sangre , Semaforinas/sangre , Adulto , Enfermedades Cardiovasculares/sangre , Enfermedades Cardiovasculares/genética , Estudios de Casos y Controles , Estudios de Cohortes , Efrinas/genética , Femenino , Humanos , Masculino , Persona de Mediana Edad , Netrina-1/genética , Semaforinas/genética , Transcriptoma
11.
Catheter Cardiovasc Interv ; 94(1): 61-69, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-30604493

RESUMEN

BACKGROUND: Polymer-free amphilimus-eluting stents (PF-AES) represent a novel elution-technology in coronary stenting. We aimed to assess 1-year clinical outcomes of PF-AES as compared to latest-generation permanent polymer zotarolimus-eluting stents (PP-ZES) in a real-world all-comers setting. METHODS: A prospective registry of patients treated with either PF-AES or PP-ZES between 2014 and 2016 was conducted. The primary outcome was defined as major adverse cardiac and cerebrovascular events (MACCE), and the secondary outcome was defined as target-lesion failure (TLF) at 1 year. To account for measured confounders, a propensity-score adjusted Cox proportional-hazard model was built to evaluate clinical outcomes. RESULTS: A total of 734 consecutive patients with 1,269 DES implantations were enrolled. The population was characterized by 28% diabetes, 24% ST-segment elevation myocardial infarction, and a high number of complex lesions (69%). The rate of MACCE was 11.5% for PF-AES and 13.6% for PP-ZES, plog-rank = 0.11. TLF was numerically lower in PF-AES as compared to PP-ZES (5.4 vs. 6.1%, plog-rank = 0.68). After propensity-score adjustment, PF-AES showed a trend toward a lower rate of MACCE and a favorable rate of TLF as compared to PP-ZES (HR 0.70; 95%CI 0.45 to 1.10, P = 0.12; and HR 0.88; 95%CI 0.47 to 1.65, P = 0.68, respectively). Rates of definite ST were low (0.8 vs. 0.3%, plog-rank = 0.62). CONCLUSIONS: Our study suggests that implantation of PF-AES was safe and effective in real-world patients, with low-rates of MACCE and TLF at 1 year. Our data needs to be confirmed by a large trial to evaluate the clinical outcomes of this novel polymer-free, eluting-technology used in PF-AES.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Sirolimus/análogos & derivados , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Puntaje de Propensión , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Sirolimus/administración & dosificación , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
12.
Catheter Cardiovasc Interv ; 91(3): 410-416, 2018 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-28544782

RESUMEN

BACKGROUND: Amphilimus sirolimus-eluting stents (A-SES) represent a novel elution technology in the current era of drug-eluting stents with promising results in patients with diabetes mellitus. At present no large trial has been designed to evaluate clinical outcomes of A-SES as compared to new-generation drug-eluting stents in unselected patients. Accordingly, we designed this trial to evaluate clinical noninferiority of A-SES as compared with zotarolimus-eluting stents (ZES) in a real-world, all-comers setting. STUDY DESIGN: ReCre8 is a prospective multicenter randomized clinical trial evaluating the clinical outcomes of A-SES as compared with ZES in all-comers requiring percutaneous coronary intervention. Patients are randomized 1:1 to receive either A-SES or ZES. On-site block-randomization is stratified by diabetes mellitus, and troponin status to perform prespecified subanalyses. Patients receive 1-month of dual antiplatelet therapy (DAPT) when troponin-negative, or 12-months of DAPT when troponin-positive. The primary endpoint is target-lesion failure at 1-year follow-up. A total of 1,532 patients will be enrolled to demonstrate clinical noninferiority of A-SES with at least 80% power, a noninferiority margin of 3.5% and a type-I-error of 0.05. CONCLUSIONS: ReCre8 (NCT02328898) is the first randomized multicenter trial with a head-to-head comparison of A-SES as compared with ZES to investigate the clinical safety and efficacy of these new-generation DES in a real-world, all-comers population.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Sirolimus/análogos & derivados , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estudios de Equivalencia como Asunto , Humanos , Estudios Multicéntricos como Asunto , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Diseño de Prótesis , Ensayos Clínicos Controlados Aleatorios como Asunto , Factores de Riesgo , Sirolimus/administración & dosificación , Factores de Tiempo , Resultado del Tratamiento
13.
Catheter Cardiovasc Interv ; 92(1): 68-75, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29521471

RESUMEN

OBJECTIVES: To describe the use of fractional flow reserve (FFR) and intravascular ultrasound (IVUS) in the evaluation of patients with anomalous coronary arteries originating from the opposite sinus of Valsalva (ACAOS). BACKGROUND: ACAOS of the right and left coronary are rare, but may lead to symptoms and impose a risk for sudden cardiac death, depending on several anatomical features. Assessment and risk estimation is challenging in (nonathlete) adults, especially if they present without symptoms or with atypical complaints. METHODS: The team retrospectively studied 30 consecutive patients with ACAOS with interarterial course, who received IVUS- and FFR-guided treatment at our institution between October 2010 and September 2017. RESULTS: FFR was abnormal in only seven patients. IVUS showed the typical slit-like anatomy of the orifice in 23 patients. Based on FFR and/or IVUS results, in conjunction with the clinical presentation, clinical decision was made. A decision for intervention was made if at least two out of three entities were abnormal. Intervention implied unroofing of the coronary artery (n = 10) or coronary artery bypass grafting (n = 1). In all other patients a conservative strategy was followed. No adverse events occurred in the total population after a median of 37 (0-62) months of follow-up. CONCLUSIONS: Conservative treatment may be justifiable in adult patients with ACAOS in the presence of normal FFR and nonsuspicious symptoms, despite the presence of an interarterial course and/or slitlike orifice on IVUS. We recommend the use of FFR and IVUS in the standard work-up for adult patients with ACAOS and propose the use of a flowchart to aid in decision-making.


Asunto(s)
Cateterismo Cardíaco , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico , Seno Aórtico/diagnóstico por imagen , Ultrasonografía Intervencional , Adulto , Toma de Decisiones Clínicas , Angiografía Coronaria , Anomalías de los Vasos Coronarios/fisiopatología , Anomalías de los Vasos Coronarios/terapia , Técnicas de Apoyo para la Decisión , Femenino , Humanos , Masculino , Persona de Mediana Edad , Selección de Paciente , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Seno Aórtico/fisiopatología , Resultado del Tratamiento
14.
Catheter Cardiovasc Interv ; 92(3): 466-476, 2018 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-29314563

RESUMEN

OBJECTIVES: To evaluate the outcomes of subadventitial stenting (SS) around occluded stents for recanalizing in-stent chronic total occlusions (IS-CTOs). BACKGROUND: There is little evidence on the outcomes of SS for IS-CTO. METHODS: We examined the outcomes of SS for IS-CTO PCI at 14 centers between July 2011 and June 2017, and compared them to historical controls recanalized using within-stent stenting (WSS). Target-vessel failure (TVF) on follow-up was the endpoint of this study, and was defined as a composite of cardiac death, target-vessel myocardial infarction, and target-vessel revascularization. RESULTS: During study period, 422 IS-CTO PCIs were performed, of which 32 (7.6%) were recanalized with SS, usually when conventional approaches failed. The most frequent CTO vessel was the right coronary artery (72%). Mean J-CTO score was 3.1 ± 0.9. SS was antegrade in 53%, and retrograde in 47%. Part of the occluded stent was crushed in 37%, while the whole stent was crushed in 63%. Intravascular imaging was used in 59%. One patient (3.1%) suffered tamponade. Angiographic follow-up was performed in 10/32 patients: stents were patent in six cases, one had mild neointimal hyperplasia, and three had severe restenosis at the SS site. Clinical follow-up was available for 29/32 patients for a mean of 388 ± 303 days. The 24-month incidence of TVF was 13.8%, which was similar to historical controls treated with WSS (19.5%, P = 0.49). CONCLUSIONS: SS is rarely performed, usually as last resort, to recanalize complex IS-CTOs. It is associated with favorable acute and mid-term outcomes, but given the small sample size of our study additional research is warranted.


Asunto(s)
Oclusión Coronaria/terapia , Reestenosis Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Anciano , Australia , Canadá , Enfermedad Crónica , Angiografía por Tomografía Computarizada , Angiografía Coronaria/métodos , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/etiología , Oclusión Coronaria/mortalidad , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Reestenosis Coronaria/mortalidad , Europa (Continente) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/métodos , Intervención Coronaria Percutánea/mortalidad , Diseño de Prótesis , Sistema de Registros , Retratamiento , Estudios Retrospectivos , Factores de Tiempo , Tomografía de Coherencia Óptica , Resultado del Tratamiento , Ultrasonografía Intervencional , Estados Unidos , Grado de Desobstrucción Vascular
18.
Circ Res ; 113(9): 1065-75, 2013 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-23963726

RESUMEN

RATIONALE: RNA-binding proteins are critical post-transcriptional regulators of RNA and can influence pre-mRNA splicing, RNA localization, and stability. The RNA-binding protein Quaking (QKI) is essential for embryonic blood vessel development. However, the role of QKI in the adult vasculature, and in particular in vascular smooth muscle cells (VSMCs), is currently unknown. OBJECTIVE: We sought to determine the role of QKI in regulating adult VSMC function and plasticity. METHODS AND RESULTS: We identified that QKI is highly expressed by neointimal VSMCs of human coronary restenotic lesions, but not in healthy vessels. In a mouse model of vascular injury, we observed reduced neointima hyperplasia in Quaking viable mice, which have decreased QKI expression. Concordantly, abrogation of QKI attenuated fibroproliferative properties of VSMCs, while potently inducing contractile apparatus protein expression, rendering noncontractile VSMCs with the capacity to contract. We identified that QKI localizes to the spliceosome, where it interacts with the myocardin pre-mRNA and regulates the splicing of alternative exon 2a. This post-transcriptional event impacts the Myocd_v3/Myocd_v1 mRNA balance and can be modulated by mutating the quaking response element in exon 2a of myocardin. Furthermore, we identified that arterial damage triggers myocardin alternative splicing and is tightly coupled with changes in the expression levels of distinct QKI isoforms. CONCLUSIONS: We propose that QKI is a central regulator of VSMC phenotypic plasticity and that intervention in QKI activity can ameliorate pathogenic, fibroproliferative responses to vascular injury.


Asunto(s)
Proliferación Celular , Músculo Liso Vascular/metabolismo , Miocitos del Músculo Liso/metabolismo , Proteínas de Unión al ARN/metabolismo , Empalme Alternativo , Animales , Traumatismos de las Arterias Carótidas/metabolismo , Arteria Carótida Común/metabolismo , Arteria Carótida Común/patología , Movimiento Celular , Reestenosis Coronaria/metabolismo , Reestenosis Coronaria/patología , Vasos Coronarios/metabolismo , Vasos Coronarios/patología , Modelos Animales de Enfermedad , Matriz Extracelular/metabolismo , Femenino , Regulación de la Expresión Génica , Células HEK293 , Humanos , Hiperplasia , Ratones , Ratones Endogámicos C57BL , Ratones Quaking , Músculo Liso Vascular/patología , Miocitos del Músculo Liso/patología , Neointima , Proteínas Nucleares/genética , Proteínas Nucleares/metabolismo , Fenotipo , Interferencia de ARN , Proteínas de Unión al ARN/genética , Transactivadores/genética , Transactivadores/metabolismo , Transfección
19.
Arterioscler Thromb Vasc Biol ; 33(3): e75-83, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23288165

RESUMEN

OBJECTIVE: Despite common disbelief that neutrophils are involved in atherosclerosis, evidence is accumulating for a causal role of neutrophils in atherosclerosis. CC chemokine ligand (CCL)3 is an inflammatory chemokine and its expression is significantly increased during atherosclerotic lesion formation in mice. It has recently been shown that under conditions of inflammation neutrophils can migrate along a CCL3 gradient. In this study, we aimed to elucidate the role of leukocyte-derived CCL3 in atherogenesis. METHODS AND RESULTS: Irradiated low density lipoprotein receptor(-/-) mice, reconstituted with CCL3(-/-) or littermate bone marrow showed markedly reduced CCL3 response to lipopolysaccharide treatment, establishing the critical relevance of leukocytes as source of CCL3. Hematopoietic deficiency of CCL3 significantly reduced aortic sinus lesion formation by 31% after 12 weeks of western-type diet. Interestingly, whereas plaque macrophage, collagen, and vascular smooth muscle cell content were unchanged, neutrophil adhesion to and presence in plaques was significantly attenuated in CCL3(-/-) chimeras. These mice had reduced circulating neutrophil numbers, which could be ascribed to an increased neutrophil turnover and CCL3(-/-) neutrophils were shown to be less responsive toward the neutrophil chemoattractant CXC chemokine ligand 1. CONCLUSIONS: Our data indicate that under conditions of acute inflammation leukocyte-derived CCL3 can induce neutrophil chemotaxis toward the atherosclerotic plaque, thereby accelerating lesion formation.


Asunto(s)
Enfermedades de las Arterias Carótidas/prevención & control , Arteria Carótida Común/inmunología , Quimiocina CCL3/deficiencia , Quimiotaxis de Leucocito , Leucocitos/inmunología , Infiltración Neutrófila , Neutrófilos/inmunología , Animales , Apoptosis , Trasplante de Médula Ósea , Enfermedades de las Arterias Carótidas/genética , Enfermedades de las Arterias Carótidas/inmunología , Enfermedades de las Arterias Carótidas/patología , Arteria Carótida Común/patología , Adhesión Celular , Células Cultivadas , Quimiocina CCL3/genética , Quimiocina CXCL1/metabolismo , Ciclofosfamida , Grasas de la Dieta , Modelos Animales de Enfermedad , Femenino , Regulación de la Expresión Génica , Lipopolisacáridos , Masculino , Ratones , Ratones Endogámicos C57BL , Ratones Noqueados , Neutropenia/inducido químicamente , Neutropenia/inmunología , Placa Aterosclerótica , ARN Mensajero/metabolismo , Receptores de LDL/deficiencia , Receptores de LDL/genética , Factores de Tiempo , Irradiación Corporal Total
20.
Front Immunol ; 15: 1327051, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38807599

RESUMEN

Introduction: The CC chemokine ligand 18 (CCL18) is a chemokine highly expressed in chronic inflammation in humans. Recent observations of elevated CCL18 plasma levels in patients with acute cardiovascular syndromes prompted an investigation into the role of CCL18 in the pathogenesis of human and mouse atherosclerosis. Methods and results: CCL18 was profoundly upregulated in ruptured human atherosclerotic plaque, particularly within macrophages. Repeated administration of CCL18 in Western-type diet-fed ApoE -/- mice or PCSK9mut-overexpressing wild type (WT) mice led to increased plaque burden, enriched in CD3+ T cells. In subsequent experimental and molecular modeling studies, we identified CCR6 as a functional receptor mediating CCL18 chemotaxis, intracellular Ca2+ flux, and downstream signaling in human Jurkat and mouse T cells. CCL18 failed to induce these effects in vitro in murine spleen T cells with CCR6 deficiency. The ability of CCR6 to act as CCL18 receptor was confirmed in vivo in an inflammation model, where subcutaneous CCL18 injection induced profound focal skin inflammation in WT but not in CCR6-/- mice. This inflammation featured edema and marked infiltration of various leukocyte subsets, including T cells with a Th17 signature, supporting CCR6's role as a Th17 chemotactic receptor. Notably, focal overexpression of CCL18 in plaques was associated with an increased presence of CCR6+ (T) cells. Discussion: Our studies are the first to identify the CCL18/CCR6 axis as a regulator of immune responses in advanced murine and human atherosclerosis.


Asunto(s)
Aterosclerosis , Quimiocinas CC , Receptores CCR6 , Animales , Humanos , Aterosclerosis/inmunología , Aterosclerosis/metabolismo , Ratones , Receptores CCR6/metabolismo , Receptores CCR6/genética , Quimiocinas CC/metabolismo , Quimiocinas CC/genética , Modelos Animales de Enfermedad , Ratones Endogámicos C57BL , Células Jurkat , Placa Aterosclerótica/inmunología , Ratones Noqueados , Masculino , Linfocitos T/inmunología , Linfocitos T/metabolismo , Células Th17/inmunología , Células Th17/metabolismo , Femenino , Ratones Noqueados para ApoE
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA