RESUMEN
BACKGROUND: Incomplete atrial lesions resulting in pulmonary vein-left atrium reconnection after pulmonary vein antrum isolation (PVAI), are related to atrial fibrillation (AF) recurrence. Unfortunately, during the PVAI procedure, fluoroscopy and electroanatomic mapping cannot accurately determine the location and size of the ablation lesions in the atrial wall and this can result in incomplete PVAI lesions (PVAI-L) after radiofrequency catheter ablation (RFCA). AIM: We seek to evaluate whether cardiac magnetic resonance (CMR), immediately after RFCA of AF, can identify PVAI-L by characterizing the left atrial tissue. METHODS: Ten patients (63.1 ± 5.7 years old, 80% male) receiving a RFCA for paroxysmal AF underwent a CMR before (<1 week) and after (<1 h) the PVAI. Two-dimensional dark-blood T2-weighted short tau inversion recovery (DB-STIR), Three-dimensional inversion-recovery prepared long inversion time (3D-TWILITE) and three-dimensional late gadolinium enhancement (3D-LGE) images were performed to visualize PVAI-L. RESULTS: The PVAI-L was visible in 10 patients (100%) using 3D-TWILITE and 3D-LGE. Conversely, On DB-STIR, the ablation core of the PAVI-L could not be identified because of a diffuse high signal of the atrial wall post-PVAI. Microvascular obstruction was identified in 7 (70%) patients using 3D-LGE. CONCLUSION: CMR can visualize PVAI-L immediately after the RFCA of AF even without the use of contrast agents. Future studies are needed to understand if the use of CMR for PVAI-L detection after RFCA can improve the results of ablation procedures.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Medios de Contraste , Resultado del Tratamiento , Gadolinio , Espectroscopía de Resonancia Magnética , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugíaRESUMEN
Pulsatile spinal cord and CSF velocities related to the cardiac cycle can be depicted by phase-contrast MRI. Among patients with spontaneous intracranial hypotension, we have recently described relevant differences compared with healthy controls in segment C2/C3. The method might be a promising tool to solve clinical and diagnostic ambiguities. Therefore, it is important to understand the physiological range and the effects of clinical and anatomical parameters in healthy volunteers. Within a prospective study, 3D T2 -weighted MRI for spinal canal anatomy and cardiac-gated phase-contrast MRI adapted to CSF flow and spinal cord motion for time-resolved velocity data and derivatives were performed in 70 participants (age 20-79 years) in segments C2/C3 and C5/C6. Correlations were analyzed by multiple linear regression models; p < 0.01 was required to assume a significant impact of clinical or anatomical data quantified by the regression coefficient B. Data showed that in C2/C3, the CSF and spinal cord craniocaudal velocity ranges were 4.5 ± 0.9 and 0.55 ± 0.15 cm/s; the total displacements were 1.1 ± 0.3 and 0.07 ± 0.02 cm, respectively. The craniocaudal range of the CSF flow rate was 8.6 ± 2.4 mL/s; the CSF stroke volume was 2.1 ± 0.7 mL. In C5/C5, physiological narrowing of the spinal canal caused higher CSF velocity ranges and lower stroke volume (C5/C6 B = +1.64 cm/s, p < 0.001; B = -0.4 mL, p = 0.002, respectively). Aging correlated to lower spinal cord motion (e.g., B = -0.01 cm per 10 years of aging, p < 0.001). Increased diastolic blood pressure was associated with lower spinal cord motion and CSF flow parameters (e.g., C2/C3 CSF stroke volume B = -0.3 mL per 10 mmHg, p < 0.001). Males showed higher CSF flow and spinal cord motion (e.g., CSF stroke volume B = +0.5 mL, p < 0.001; total displacement spinal cord B = +0.016 cm, p = 0.002). We therefore propose to stratify data for age and sex and to adjust for diastolic blood pressure and segmental narrowing in future clinical studies.
RESUMEN
Preclinical 4D flow MRI remains challenging and is restricted for parallel imaging acceleration due to the limited number of available receive channels. A radial acquisition with combined parallel imaging and temporal compressed sensing reconstruction was implemented to achieve accelerated preclinical 4D flow MRI. In order to increase the accuracy of the measured velocities, a quantitative evaluation of different temporal regularization weights for the compressed sensing reconstruction based on velocity instead of magnitude data is performed. A 3D radial retrospectively triggered phase contrast sequence with a combined parallel imaging and compressed sensing reconstruction with temporal regularization was developed. It was validated in a phantom and in vivo (C57BL/6 J mice), against an established fully sampled Cartesian sequence. Different undersampling factors (USFs [12, 15, 20, 30, 60]) were evaluated, and the effect of undersampling was analyzed in detail for magnitude and velocity data. Temporal regularization weights λ were evaluated for different USFs. Acceleration factors of up to 20 compared with full Nyquist sampling were achieved. The peak flow differences compared with the Cartesian measurement were the following: USF 12, 3.38%; USF 15, 4.68%; USF 20, 0.95%. The combination of 3D radial center-out trajectories and compressed sensing reconstruction is robust against motion and flow artifacts and can significantly reduce measurement time to 30 min at a resolution of 180 µm3 . Concisely, radial acquisition with combined compressed sensing and parallel imaging proved to be an excellent method for analyzing complex flow patterns in mice.
Asunto(s)
Aorta/diagnóstico por imagen , Hemorreología , Imagen por Resonancia Magnética , Aceleración , Animales , Modelos Animales de Enfermedad , Procesamiento de Imagen Asistido por Computador , Ratones Endogámicos C57BL , Ratones Noqueados , Fantasmas de Imagen , Pulso Arterial , Reproducibilidad de los ResultadosRESUMEN
BACKGROUND: Measuring hepatic R2* by fitting a monoexponential model to the signal decay of a multigradient-echo (mGRE) sequence noninvasively determines hepatic iron content (HIC). Concurrent hepatic steatosis introduces signal oscillations and confounds R2* quantification with standard monoexponential models. PURPOSE: To evaluate an autoregressive moving average (ARMA) model for accurate quantification of HIC in the presence of fat using biopsy as the reference. STUDY TYPE: Phantom study and in vivo cohort. POPULATION: Twenty iron-fat phantoms covering clinically relevant R2* (30-800 s-1 ) and fat fraction (FF) ranges (0-40%), and 10 patients (four male, six female, mean age 18.8 years). FIELD STRENGTH/SEQUENCE: 2D mGRE acquisitions at 1.5 T and 3 T. ASSESSMENT: Phantoms were scanned at both field strengths. In vivo data were analyzed using the ARMA model to determine R2* and FF values, and compared with biopsy results. STATISTICAL TESTS: Linear regression analysis was used to compare ARMA R2* and FF results with those obtained using a conventional monoexponential model, complex-domain nonlinear least squares (NLSQ) fat-water model, and biopsy. RESULTS: In phantoms and in vivo, all models produced R2* and FF values consistent with expected values in low iron and low/high fat conditions. For high iron and no fat phantoms, monoexponential and ARMA models performed excellently (slopes: 0.89-1.07), but NLSQ overestimated R2* (slopes: 1.14-1.36) and produced false FFs (12-17%) at 1.5 T; in high iron and fat phantoms, NLSQ (slopes: 1.02-1.16) outperformed monoexponential and ARMA models (slopes: 1.23-1.88). The results with NLSQ and ARMA improved in phantoms at 3 T (slopes: 0.96-1.04). In patients, mean R2*-HIC estimates for monoexponential and ARMA models were close to biopsy-HIC values (slopes: 0.90-0.95), whereas NLSQ substantially overestimated HIC (slope 1.4) and produced false FF values (4-28%) with very high SDs (15-222%) in patients with high iron overload and no steatosis. DATA CONCLUSION: ARMA is superior in quantifying R2* and FF under high iron and no fat conditions, whereas NLSQ is superior for high iron and concurrent fat at 1.5 T. Both models give improved R2* and FF results at 3 T. LEVEL OF EVIDENCE: 2 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2019;50:1620-1632.
Asunto(s)
Hígado Graso/diagnóstico por imagen , Hígado Graso/metabolismo , Hierro/análisis , Hígado/diagnóstico por imagen , Hígado/metabolismo , Tejido Adiposo/diagnóstico por imagen , Adolescente , Adulto , Biopsia , Calibración , Niño , Preescolar , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Sobrecarga de Hierro , Análisis de los Mínimos Cuadrados , Imagen por Resonancia Magnética , Masculino , Fantasmas de Imagen , Análisis de Regresión , Adulto JovenRESUMEN
BACKGROUND: Current R2*-MRI techniques for measuring hepatic iron content (HIC) use various acquisition types and fitting models. PURPOSE: To evaluate the accuracy and precision of R2*-HIC acquisition and fitting methods. STUDY TYPE: Signal simulations, phantom study, and prospective in vivo cohort. POPULATION: In all, 132 patients (58/74 male/female, mean age 17.7 years). FIELD STRENGTH/SEQUENCE: 2D-multiecho gradient-echo (GRE) and ultrashort echo time (UTE) acquisitions at 1.5T. ASSESSMENT: Synthetic MR signals were created to mimic published GRE and UTE methods, using different R2* values (25-2000 s-1 ) and signal-to-noise ratios (SNR). Phantoms with varying iron concentrations were scanned at 1.5T. In vivo data were analyzed from 132 patients acquired at 1.5T. R2* was estimated by fitting using three signal models. Accuracy and precision of R2* measurements for UTE acquisition parameters (SNR, echo spacing [ΔTE], maximum echo time [TEmax ]) and fitting methods were compared for simulated, phantom, and in vivo datasets. STATISTICAL TESTS: R2* accuracy was determined from the relative error and by linear regression analysis. Precision was evaluated using coefficient of variation (CoV) analysis. RESULTS: In simulations, all models had high R2* accuracy (error <5%) and precision (CoV <10%) for all SNRs, shorter ΔTE (≤0.5 msec), and longer TEmax (≥10.1 msec); except the constant offset model overestimated R2* at the lowest SNR. In phantoms and in vivo, all models produced similar R2* values for different SNRs and shorter ΔTEs (slopes: 0.99-1.06, R2 > 0.99, P < 0.001). In all experiments, R2* results degraded for high R2* values with longer ΔTE (≥1 msec). In vivo, shorter and longer TEmax gave similar R2* results (slopes: 1.02-1.06, R2 > 0.99, P < 0.001) for the noise subtraction model for 25≤R2*≤2000 s-1 . However, both quadratic and constant offset models, using shorter TEmax (≤4.7 msec) overestimated R2* and yielded high CoVs up to â¼170% for low R2* (<250 s-1 ). DATA CONCLUSION: UTE with TEmax ≥ 10.1 msec and ΔTE ≤ 0.5 msec yields accurate R2* estimates over the entire clinical HIC range. Monoexponential fitting with noise subtraction is the most robust signal model to changes in UTE parameters and achieves the highest R2* accuracy and precision. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:1475-1488.
Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Sobrecarga de Hierro/diagnóstico por imagen , Sobrecarga de Hierro/metabolismo , Hígado/diagnóstico por imagen , Hígado/metabolismo , Imagen por Resonancia Magnética/métodos , Adolescente , Estudios de Cohortes , Femenino , Humanos , Hierro/metabolismo , Masculino , Fantasmas de Imagen , Estudios Prospectivos , Reproducibilidad de los Resultados , Relación Señal-RuidoRESUMEN
OBJECTIVES: Guidewires are indispensable tools for intravascular MR-guided interventions. Recently, an MR-safe guidewire made from a glass-fiber/epoxy compound material with embedded iron particles was developed. The size of the induced susceptibility artifact, and thus the guidewire's visibility, depends on its orientation against B 0. We present a radial acquisition scheme with variable echo times that aims to reduce the artifact's orientation dependency. MATERIALS AND METHODS: The radial acquisition scheme uses sine-squared modulated echo times depending on the physical direction of the spoke to balance the susceptibility artifact of the guidewire. The acquisition scheme was studied in simulations based on dipole fields and in phantom experiments for different orientations of the guidewire against B 0. The simulated and measured artifact widths were quantitatively compared. RESULTS: Compared to acquisitions with non-variable echo times, the proposed acquisition scheme shows a reduced angular variability. For the two main orientations (i.e., parallel and perpendicular to B 0), the ratio of the artifact widths was reduced from about 2.2 (perpendicular vs. parallel) to about 1.2 with the variable echo time approach. CONCLUSION: The reduction of the orientation dependency of the guidewire's artifact via sine-squared varying echo times could be verified in simulations and measurements. The more balanced artifact allows for a better overall visibility of the guidewire.
Asunto(s)
Artefactos , Procedimientos Endovasculares , Vidrio , Imagen por Resonancia Magnética Intervencional/instrumentación , Imagen por Resonancia Magnética/instrumentación , Cateterismo , Simulación por Computador , Compuestos Epoxi , Diseño de Equipo , Humanos , Fantasmas de ImagenRESUMEN
PURPOSE: To present an image registration method for renal blood oxygen level-dependent (BOLD) measurements that enables semiautomatic assessment of parenchymal and medullary R2* changes under a functional challenge. METHODS: In a series of breath-hold acquisitions, three-dimensional data were acquired initially for prospective image registration of subsequent BOLD measurements. An algorithm for kidney alignment for BOLD renal imaging (KALIBRI) was implemented to detect the positions of the left and right kidney so that the kidneys were acquired in the subsequent BOLD measurement at consistent anatomical locations. Residual in-plane distortions were corrected retrospectively so that semiautomatic dynamic R2* measurements of the renal cortex and medulla become feasible. KALIBRI was tested in six healthy volunteers during a series of BOLD experiments, which included a 600- to 1000-mL water challenge. RESULTS: Prospective image registration and BOLD imaging of each kidney was achieved within a total measurement time of about 17 s, enabling its execution within a single breath-hold. KALIBRI improved the registration by up to 35% as found with mutual information measures. In four volunteers, a medullary R2* decrease of up to 40% was observed after water ingestion. CONCLUSION: KALIBRI improves the quality of two-dimensional time-resolved renal BOLD MRI by aligning local renal anatomy, which allows for consistent R2* measurements over many breath-holds. Magn Reson Med 77:1573-1582, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Asunto(s)
Contencion de la Respiración , Interpretación de Imagen Asistida por Computador/métodos , Riñón/metabolismo , Imagen por Resonancia Magnética/métodos , Oximetría/métodos , Oxígeno/metabolismo , Técnica de Sustracción , Algoritmos , Humanos , Aumento de la Imagen/métodos , Riñón/anatomía & histología , Pruebas de Función Renal/métodos , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y EspecificidadRESUMEN
PURPOSE: Hepatic iron content (HIC) quantification via transverse relaxation rate (R2*)-MRI using multi-gradient echo (mGRE) imaging is compromised toward high HIC or at higher fields due to the rapid signal decay. Our study aims at presenting an optimized 2D ultrashort echo time (UTE) sequence for R2* quantification to overcome these limitations. METHODS: Two-dimensional UTE imaging was realized via half-pulse excitation and radial center-out sampling. The sequence includes chemically selective saturation pulses to reduce streaking artifacts from subcutaneous fat, and spatial saturation (sSAT) bands to suppress out-of-slice signals. The sequence employs interleaved multi-echo readout trains to achieve dense temporal sampling of rapid signal decays. Evaluation was done at 1.5 Tesla (T) and 3T in phantoms, and clinical applicability was demonstrated in five patients with biopsy-confirmed massively high HIC levels (>25 mg Fe/g dry weight liver tissue). RESULTS: In phantoms, the sSAT pulses were found to remove out-of-slice contamination, and R2* results were in excellent agreement to reference mGRE R2* results (slope of linear regression: 1.02/1.00 for 1.5/3T). UTE-based R2* quantification in patients with massive iron overload proved successful at both field strengths and was consistent with biopsy HIC values. CONCLUSION: The UTE sequence provides a means to measure R2* in patients with massive iron overload, both at 1.5T and 3T. Magn Reson Med 78:1839-1851, 2017. © 2017 Wiley Periodicals, Inc.
Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Sobrecarga de Hierro/diagnóstico por imagen , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Humanos , Hígado/química , Fantasmas de Imagen , Factores de TiempoRESUMEN
OBJECTIVE: The objective of this study is to evaluate radial free-breathing (FB) multiecho ultrashort TE (UTE) imaging as an alternative to Cartesian FB multiecho gradient-recalled echo (GRE) imaging for quantitative assessment of hepatic iron content (HIC) in sedated patients and subjects unable to perform breath-hold (BH) maneuvers. MATERIALS AND METHODS: FB multiecho GRE imaging and FB multiecho UTE imaging were conducted for 46 test group patients with iron overload who could not complete BH maneuvers (38 patients were sedated, and eight were not sedated) and 16 control patients who could complete BH maneuvers. Control patients also underwent standard BH multiecho GRE imaging. Quantitative R2* maps were calculated, and mean liver R2* values and coefficients of variation (CVs) for different acquisitions and patient groups were compared using statistical analysis. RESULTS: FB multiecho GRE images displayed motion artifacts and significantly lower R2* values, compared with standard BH multiecho GRE images and FB multiecho UTE images in the control cohort and FB multiecho UTE images in the test cohort. In contrast, FB multiecho UTE images produced artifact-free R2* maps, and mean R2* values were not significantly different from those measured by BH multiecho GRE imaging. Motion artifacts on FB multiecho GRE images resulted in an R2* CV that was approximately twofold higher than the R2* CV from BH multiecho GRE imaging and FB multiecho UTE imaging. The R2* CV was relatively constant over the range of R2* values for FB multiecho UTE, but it increased with increases in R2* for FB multiecho GRE imaging, reflecting that motion artifacts had a stronger impact on R2* estimation with increasing iron burden. CONCLUSION: FB multiecho UTE imaging was less motion sensitive because of radial sampling, produced excellent image quality, and yielded accurate R2* estimates within the same acquisition time used for multiaveraged FB multiecho GRE imaging. Thus, FB multiecho UTE imaging is a viable alternative for accurate HIC assessment in sedated children and patients who cannot complete BH maneuvers.
Asunto(s)
Sobrecarga de Hierro/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Artefactos , Contencion de la Respiración , Estudios de Casos y Controles , Niño , Preescolar , Femenino , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Estudios RetrospectivosRESUMEN
BACKGROUND: Liver R2* values calculated from multi-gradient echo (mGRE) magnetic resonance images (MRI) are strongly correlated with hepatic iron concentration (HIC) as shown in several independently derived biopsy calibration studies. These calibrations were established for axial single-slice breath-hold imaging at the location of the portal vein. Scanning in multi-slice mode makes the exam more efficient, since whole-liver coverage can be achieved with two breath-holds and the optimal slice can be selected afterward. Navigator echoes remove the need for breath-holds and allow use in sedated patients. OBJECTIVE: To evaluate if the existing biopsy calibrations can be applied to multi-slice and navigator-controlled mGRE imaging in children with hepatic iron overload, by testing if there is a bias-free correlation between single-slice R2* and multi-slice or multi-slice navigator controlled R2*. MATERIALS AND METHODS: This study included MRI data from 71 patients with transfusional iron overload, who received an MRI exam to estimate HIC using gradient echo sequences. Patient scans contained 2 or 3 of the following imaging methods used for analysis: single-slice images (n = 71), multi-slice images (n = 69) and navigator-controlled images (n = 17). Small and large blood corrected region of interests were selected on axial images of the liver to obtain R2* values for all data sets. Bland-Altman and linear regression analysis were used to compare R2* values from single-slice images to those of multi-slice images and navigator-controlled images. RESULTS: Bland-Altman analysis showed that all imaging method comparisons were strongly associated with each other and had high correlation coefficients (0.98 ≤ r ≤ 1.00) with P-values ≤0.0001. Linear regression yielded slopes that were close to 1. CONCLUSION: We found that navigator-gated or breath-held multi-slice R2* MRI for HIC determination measures R2* values comparable to the biopsy-validated single-slice, single breath-hold scan. We conclude that these three R2* methods can be interchangeably used in existing R2*-HIC calibrations.
Asunto(s)
Sobrecarga de Hierro/diagnóstico por imagen , Hepatopatías/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Biopsia , Niño , Preescolar , Femenino , Humanos , MasculinoRESUMEN
PURPOSE: Fat suppression (FS) via chemically selective saturation (CHESS) eliminates fat-water oscillations in multiecho gradient echo (mGRE) R2*-MRI. However, for increasing R2* values as seen with increasing liver iron content (LIC), the water signal spectrally overlaps with the CHESS band, which may alter R2*. We investigated the effect of CHESS on R2* and developed a heuristic correction for the observed CHESS-induced R2* changes. METHODS: Eighty patients [female, n = 49; male, n = 31; mean age (± standard deviation), 18.3 ± 11.7 y] with iron overload were scanned with a non-FS and a CHESS-FS mGRE sequence at 1.5T and 3T. Mean liver R2* values were evaluated using three published fitting approaches. Measured and model-corrected R2* values were compared and statistically analyzed. RESULTS: At 1.5T, CHESS led to a systematic R2* reduction (P < 0.001 for all fitting algorithms) especially toward higher R2*. Our model described the observed changes well and reduced the CHESS-induced R2* bias after correction (linear regression slopes: 1.032/0.927/0.981). No CHESS-induced R2* reductions were found at 3T. CONCLUSION: The CHESS-induced R2* bias at 1.5T needs to be considered when applying R2*-LIC biopsy calibrations for clinical LIC assessment, which were established without FS at 1.5T. The proposed model corrects the R2* bias and could therefore improve clinical iron overload assessment based on linear R2*-LIC calibrations. Magn Reson Med 76:591-601, 2016. © 2015 Wiley Periodicals, Inc.
Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Algoritmos , Artefactos , Sobrecarga de Hierro/diagnóstico por imagen , Hepatopatías/diagnóstico por imagen , Reacción a la Transfusión/diagnóstico por imagen , Tejido Adiposo/patología , Adolescente , Adulto , Transfusión Sanguínea , Niño , Preescolar , Femenino , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Lactante , Sobrecarga de Hierro/patología , Hepatopatías/patología , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Técnica de Sustracción , Reacción a la Transfusión/patología , Adulto JovenRESUMEN
PURPOSE: To assess the feasibility of automatic needle-guide tracking by using a real-time phase-only cross correlation ( POCC phase-only cross correlation ) algorithm-based sequence for transrectal 3-T in-bore magnetic resonance (MR)-guided prostate biopsies. MATERIALS AND METHODS: This study was approved by the ethics review board, and written informed consent was obtained from all patients. Eleven patients with a prostate-specific antigen level of at least 4 ng/mL (4 µg/L) and at least one transrectal ultrasonography-guided biopsy session with negative findings were enrolled. Regions suspicious for cancer were identified on 3-T multiparametric MR images. During a subsequent MR-guided biopsy, the regions suspicious for cancer were reidentified and targeted by using the POCC phase-only cross correlation -based tracking sequence. Besides testing a general technical feasibility of the biopsy procedure by using the POCC phase-only cross correlation -based tracking sequence, the procedure times were measured, and a pathologic analysis of the biopsy cores was performed. RESULTS: Thirty-eight core samples were obtained from 25 regions suspicious for cancer. It was technically feasible to perform the POCC phase-only cross correlation -based biopsies in all regions suspicious for cancer in each patient, with adequate biopsy samples obtained with each biopsy attempt. The median size of the region suspicious for cancer was 8 mm (range, 4-13 mm). In each region suspicious for cancer (median number per patient, two; range, 1-4), a median of one core sample per region was obtained (range, 1-3). The median time for guidance per target was 1.5 minutes (range, 0.7-5 minutes). Nineteen of 38 core biopsy samples contained cancer. CONCLUSION: This study shows that it is feasible to perform transrectal 3-T MR-guided biopsies by using a POCC phase-only cross correlation algorithm-based real-time tracking sequence.
Asunto(s)
Biopsia con Aguja , Imagen por Resonancia Magnética Intervencional , Neoplasias de la Próstata/patología , Anciano , Algoritmos , Automatización , Medios de Contraste , Humanos , Masculino , Meglumina , Persona de Mediana Edad , Compuestos Organometálicos , Recto , Factores de TiempoRESUMEN
Purpose To perform a qualitative and quantitative evaluation of the novel image-navigated (iNAV) 3D late gadolinium enhancement (LGE) cardiac MRI imaging strategy in comparison with the conventional diaphragm-navigated (dNAV) 3D LGE cardiac MRI strategy for the assessment of left atrial fibrosis in atrial fibrillation (AF). Materials and Methods In this prospective study conducted between April and September 2022, 26 consecutive participants with AF (mean age, 61 ± 11 years; 19 male) underwent both iNAV and dNAV 3D LGE cardiac MRI, with equivalent spatial resolution and timing in the cardiac cycle. Participants were randomized in the acquisition order of iNAV and dNAV. Both, iNAV-LGE and dNAV-LGE images were analyzed qualitatively using a 5-point Likert scale and quantitatively (percentage of atrial fibrosis using image intensity ratio threshold 1.2), including testing for overlap in atrial fibrosis areas by calculating Dice score. Results Acquisition time of iNAV was significantly lower compared with dNAV (4.9 ± 1.1 minutes versus 12 ± 4 minutes, P < .001, respectively). There was no evidence of a difference in image quality for all prespecified criteria between iNAV and dNAV, although dNAV was the preferred image strategy in two-thirds of cases (17/26, 65%). Quantitative assessment demonstrated that mean fibrosis scores were lower for iNAV compared with dNAV (12 ± 8% versus 20 ± 12%, P < .001). Spatial correspondence between the atrial fibrosis maps was modest (Dice similarity coefficient, 0.43 ± 0.15). Conclusion iNAV-LGE acquisition in individuals with AF was more than twice as fast as dNAV acquisition but resulted in a lower atrial fibrosis score. The differences between these two strategies might impact clinical interpretation. ©RSNA, 2024.
Asunto(s)
Fibrilación Atrial , Diafragma , Anciano , Humanos , Masculino , Persona de Mediana Edad , Fibrilación Atrial/diagnóstico , Medios de Contraste , Gadolinio , Atrios Cardíacos/diagnóstico por imagen , Imagen por Resonancia Magnética , Estudios Prospectivos , FemeninoRESUMEN
PURPOSE: To quantify the effects of CSF pressure alterations on intracranial venous morphology and hemodynamics in idiopathic intracranial hypertension (IIH) and spontaneous intracranial hypotension (SIH) and assess reversibility when the underlying cause is resolved. METHODS: We prospectively examined venous volume, intracranial venous blood flow and velocity, including optic nerve sheath diameter (ONSD) as a noninvasive surrogate of CSF pressure changes in 11 patients with IIH, 11 age-matched and sex-matched healthy controls and 9 SIH patients, before and after neurosurgical closure of spinal dural leaks. We applied multiparametric MRI including 4D flow MRI, time-of-flight (TOF) and T2-weighted half-Fourier acquisition single-shot turbo-spin echo (HASTE). RESULTS: Sinus volume overlapped between groups at baseline but decreased after treatment of intracranial hypotension (pâ¯= 0.067) along with a significant increase of ONSD (pâ¯= 0.003). Blood flow in the middle and dorsal superior sagittal sinus was remarkably lower in patients with higher CSF pressure (i.e., IIH versus controls and SIH after CSF leak closure) but blood flow velocity was comparable cross-sectionally between groups and longitudinally in SIH. CONCLUSION: We were able to demonstrate the interaction of CSF pressure, venous volumetry, venous hemodynamics and ONSD using multiparametric brain MRI. Closure of CSF leaks in SIH patients resulted in symptoms suggestive of increased intracranial pressure and caused a subsequent decrease of intracranial venous volume and of blood flow within the superior sagittal sinus while ONSD increased. In contrast, blood flow parameters from 4D flow MRI did not discriminate IIH, SIH and controls as hemodynamics at baseline overlapped at most vessel cross-sections.
Asunto(s)
Presión del Líquido Cefalorraquídeo , Circulación Cerebrovascular , Hipotensión Intracraneal , Seudotumor Cerebral , Humanos , Femenino , Masculino , Adulto , Hipotensión Intracraneal/diagnóstico por imagen , Hipotensión Intracraneal/fisiopatología , Circulación Cerebrovascular/fisiología , Seudotumor Cerebral/fisiopatología , Seudotumor Cerebral/diagnóstico por imagen , Seudotumor Cerebral/cirugía , Presión del Líquido Cefalorraquídeo/fisiología , Venas Cerebrales/diagnóstico por imagen , Venas Cerebrales/fisiopatología , Persona de Mediana Edad , Angiografía por Resonancia Magnética/métodos , Velocidad del Flujo Sanguíneo/fisiología , Imagenología Tridimensional/métodos , Estudios Prospectivos , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos , Sensibilidad y Especificidad , Hemodinámica/fisiología , Hipertensión Intracraneal/fisiopatología , Hipertensión Intracraneal/diagnóstico por imagenRESUMEN
PURPOSE: To evaluate a novel imaging sequence termed crushed rephased orthogonal slice selection (CROSS) that uses the available time in long echo time (TE) gradient echo (GRE) imaging-as employed for proton resonance frequency (PRF) shift thermometry-to simultaneously acquire two orthogonal magnetic resonance imaging (MRI) temperature maps around the target region. MATERIALS AND METHODS: The CROSS sequence encodes a second orthogonal slice between excitation and data readout in long-TE imaging and applies dedicated crusher (CR) gradients to separate the signals from the two slices. Numerical simulations of the Bloch equations and phantom experiments were performed to analyze the MR signal. In phantom and in vivo experiments with two domestic pigs, the applicability of the CROSS sequence for temperature mapping of thermal therapies with focused ultrasound and laser was studied. RESULTS: A successful separation of the signals from the two slices was achieved for CR dephasing lengths approaching the in-plane resolution. In the two animal experiments, CROSS temperature mapping could be successfully demonstrated at a temporal resolution of 2-3 seconds and a temperature uncertainty of 3-4K. CONCLUSION: At the expense of a reduced signal in the overlap of the two slices, the CROSS sequence achieves an improvement of temporal resolution by 50%, without requiring further acceleration techniques such as parallel imaging, over conventional sequential GRE sequences employing the same repetition time as the CROSS sequence acquires two slices within one repetition interval.
Asunto(s)
Algoritmos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Músculo Esquelético/fisiopatología , Músculo Esquelético/cirugía , Cirugía Asistida por Computador/métodos , Termografía/métodos , Animales , Almacenamiento y Recuperación de la Información/métodos , Imagen por Resonancia Magnética/instrumentación , Músculo Esquelético/patología , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Cirugía Asistida por Computador/instrumentación , Porcinos , Termografía/instrumentaciónRESUMEN
OBJECT: Proton resonance frequency shift thermometry is sensitive to breathing motion that leads to incorrect phase differences. In this work, a novel velocity-sensitive navigator technique for triggering MR thermometry image acquisition is presented. MATERIALS AND METHODS: A segmented echo planar imaging pulse sequence was modified for velocity-triggered temperature mapping. Trigger events were generated when the estimated velocity value was less than 0.2 cm/s during the slowdown phase in parallel to the velocity-encoding direction. To remove remaining high-frequency spikes from pulsation in real time, a Kalman filter was applied to the velocity navigator data. A phantom experiment with heating and an initial volunteer experiment without heating were performed to show the applicability of this technique. Additionally, a breath-hold experiment was conducted for comparison. RESULTS: A temperature rise of ΔT = +37.3°C was seen in the phantom experiment, and a root mean square error (RMSE) outside the heated region of 2.3°C could be obtained for periodic motion. In the volunteer experiment, a RMSE of 2.7°C/2.9°C (triggered vs. breath hold) was measured. CONCLUSION: A novel velocity navigator with Kalman filter postprocessing in real time significantly improves the temperature accuracy over non-triggered acquisitions and suggests being comparable to a breath-held acquisition. The proposed technique might be clinically applied for monitoring of thermal ablations in abdominal organs.
Asunto(s)
Imagen por Resonancia Magnética/métodos , Algoritmos , Temperatura Corporal , Imagen Eco-Planar/métodos , Diseño de Equipo , Calor , Humanos , Procesamiento de Imagen Asistido por Computador , Modelos Estadísticos , Movimiento (Física) , Fantasmas de Imagen , Protones , Respiración , Temperatura , Factores de TiempoRESUMEN
Magnetic resonance-guided percutaneous interventions with needles require fast pulse sequences with acquisition times less than 1 s to image the needle trajectory within moving organs. To guide the movement of a rigid instrument with high sampling rate, an magnetic resonance imaging method was developed that reduces the acquisition time down to a few hundred milliseconds by restricting the field of view to a small stripe around the instrument trajectory. To maintain the dynamic steady state, saturation pulses for outer volume suppression were inserted into additional repetition time-intervals. These saturation intervals were combined with three sequence variants: a spoiled gradient echo sequence, an echo-shifted steady state free precession and a balanced steady state free precession sequence. The magnetization dynamics were analyzed by means of numerical optimized simulations. Results were compared with phantom experiments and an average signal-to-suppression-ratio of 15.5 could be achieved. With a field of view reduction of up to 12.5% an update rate of six images per second could be achieved. Finally, animal experiments demonstrated the fast and reliable needle tip visualization during percutaneous magnetic resonance-guided interventions with the help of a robotic assistance system.
Asunto(s)
Imagen por Resonancia Magnética , Administración Cutánea , Animales , Simulación por Computador , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Tamaño de los Órganos , Fantasmas de Imagen , Sus scrofaRESUMEN
OBJECT: The EU directive on safety requirements (2004/40/EC) limits the exposure to time varying magnetic fields to dB /dt=200 mT/s. This action value is not clearly defined as it considers only the temporal change of the magnitude of B. Thus, only the translational motion in the magnet's fringe field is considered and rotations are neglected. MATERIALS AND METHODS: A magnetic field probe was constructed to simultaneously record the magnetic flux density B(x, y, z) with a 3-axis Hall sensor and the induced voltage due to movements with a set of three orthogonal coils. Voltages were converted into time-varying magnetic flux d Φ(x, y, z)/dt serving as an exposition parameter for both translations and rotations. To separate the two types of motion, d B/dt was additionally calculated on the basis of the Hall sensor's data. The calibrated probe was attached to the forehead of 8 healthcare workers and 17 MR physicists, and B and dΦ/dt were recorded during standard operating procedures at three different MR systems up to 7 T. RESULTS: The maximum percentage of the translational motion referring the data including both translations and rotations amounts to 32%. During volunteer measurements, maximum exposure values of dΦ/dt=21 mWb/s, dB/dt=1.40 T/s and |B|=2.75 T were found. CONCLUSION: The findings in this work indicate that both translations and rotations in the vicinity of an MR system should be taken into account, and that a single regulatory action level might not be sufficient.
Asunto(s)
Campos Electromagnéticos , Campos Magnéticos , Imagen por Resonancia Magnética/métodos , Exposición Profesional/prevención & control , Monitoreo de Radiación/métodos , Calibración , Seguridad de Equipos , Humanos , Movimiento (Física) , Movimiento , Dosis de Radiación , Protección Radiológica , Rotación , Factores de TiempoRESUMEN
Wall shear stress (WSS) has been suggested as a potential biomarker in various cardiovascular diseases and it can be estimated from phase-contrast Magnetic Resonance Imaging (PC-MRI) velocity measurements. We present a parametric sequential method for MRI-based WSS quantification consisting of a geometry identification and a subsequent approximation of the velocity field. This work focuses on its validation, investigating well controlled high-resolution in vitro measurements of turbulent stationary flows and physiological pulsatile flows in phantoms. Initial tests for in vivo 2D PC-MRI data of the ascending aorta of three volunteers demonstrate basic applicability of the method to in vivo.
Asunto(s)
Aorta , Imagen por Resonancia Magnética , Aorta/diagnóstico por imagen , Velocidad del Flujo Sanguíneo , Humanos , Fantasmas de Imagen , Estrés MecánicoRESUMEN
OBJECTIVE: Assessment of vessel walls is an integral part in diagnosis and disease monitoring of vascular diseases such as vasculitis. Vessel wall imaging (VWI), in particular of intracranial arteries, is the domain of Magnetic Resonance Imaging (MRI) - but still remains a challenge. The tortuous anatomy of intracranial arteries and the need for high resolution within clinically acceptable scan times require special technical conditions regarding the hardware and software environments. MATERIALS AND METHODS: In this work a dedicated framework for intracranial VWI is presented offering an optimized, black-blood 3D T1-weighted post-contrast Compressed Sensing (CS)-accelerated MRI sequence prototype combined with dedicated 3D-GUI supported post-processing tool for the CPR visualization of tortuous arbitrary vessel structures. RESULTS: Using CS accelerated MRI sequence, the scanning time for high-resolution 3D black-blood CS-space data could be reduced to under 10 min. These data are adequate for a further processing to extract straightened visualizations (curved planar reformats - CPR). First patient data sets could be acquired in clinical environment. CONCLUSION: A highly versatile framework for VWI visualization was demonstrated utilizing a post-processing tool to extract CPR reformats from high-resolution 3D black-blood CS-SPACE data, enabling simplified and optimized assessment of intracranial arteries in intracranial vascular disorders, especially in suspected intracranial vasculitis, by stretching their tortuous course. The processing time from about 15-20 min per patient (data acquisition and further processing) allows the integration into clinical routine.