1.
J Appl Clin Med Phys ; : e14413, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38923786

RESUMEN

PURPOSE: This study aimed to find descriptors that correlates with normal brain dose to determine the feasibility of performing fractionated stereotactic radiosurgery (SRS) for multiple brain metastases (BMs) using five linac machines. METHODS: Thirty-two patients with 1-30 BMs were enrolled. Treatment plans were created using TrueBeam, Novalis Tx, TrueBeam Edge, Halcyon, and Tomotherapy linacs. The sum of all planning target volumes (PTVs) was defined as PTVall, and the brain region excluding PTVall was defined as normal brain. The total surface area (TSA) of the PTV was calculated from the sum of the surface areas of the equivalent spheres for each PTV. Volumes receiving more than 5, 12, and 18 Gy (V5Gy, V12Gy, and V18Gy, respectively) were used for evaluation of normal brain dose. Correlations between normal brain dose and each tumor characteristic (number, PTVall, and TSA) were investigated using the Spearman rank correlation coefficient. RESULTS: Correlations between each characteristic and normal brain dose were statistically significant (p < 0.05) across all machines. The correlation coefficients between each characteristic and V18Gy for the five machines were as follows: tumor number, 0.39-0.60; PTVall, 0.79-0.93; TSA, 0.93-0.99. The fit equations between TSA and V18Gy exhibited high coefficients of determination, ranging from 0.92 to 0.99 across five machines. CONCLUSION: This study devised fractionated SRS plans using for 1-30 BMs across five linac machines to find descriptors for determining SRS feasibility based on normal brain dose. TSA proved to be a promising descriptor of SRS feasibility for treating multiple BMs.

2.
J Appl Clin Med Phys ; 24(1): e13807, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36265085

RESUMEN

Independent monitor unit verification (MUV) methods for the dynamic beam-flattening (DBF) technique have not been established. The purpose of this study was to clarify whether MU values for the DBF technique can be calculated using in-air and in-water output ratios (Sc and Scp ). Sc and Scp were measured in the DBF mode, and the phantom scatter factor (Sp ) was calculated. The difference between calculated and planned MUs with square and rectangle fields and clinical plans for different treatment sites was also evaluated. Sc values for the 4 × 4 to 24 × 24 cm2 fields of the distal multi-leaf collimator (MLC) layer at 2-cm intervals were 0.887, 0.815, 0.715, 0.716, 0.611, 0.612, 0.511, 0.373, 0.374, 0.375, and 0.374, respectively. No collimator exchange effect was observed. Sc also depends slightly on the field size of the distal MLC layer. If the distal-MLC-layered field size was less than 20% of the corresponding MLC sequence size in the proximal MLC layer, Sc was affected by >1%, which was compensated using a correction factor (CF). Sp increased as the field sizes of the MLC sequence and distal MLC leaves increased. MUs calculated using measured Sc , Sp , and CF for square and rectangle fields agreed with planned MUs within ±1.2%. A larger difference (-1.5%) between calculated and planned MUs was observed for clinical plans, whereas differences in MUs were within 2 MU for most fields (56 out of 64 fields). MU calculation for the DBF technique can be performed with Sc , Sp , and CF for independent MUV.


Asunto(s)
Aceleradores de Partículas , Planificación de la Radioterapia Asistida por Computador , Humanos , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica , Radiometría
3.
Rep Pract Oncol Radiother ; 28(3): 399-406, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37795404

RESUMEN

Background: We clarified the dose difference between the anisotropic analytical algorithm (AAA) and Acuros XB (AXB) with increasing target's air content using a virtual phantom and clinical cases. Materials and methods: Whole neck volumetric modulated arc therapy (VMAT) plan was transferred into a virtual phantom with a cylindrical air structure at the center. The diameter of the air structure was changed from 0 to 6 cm, and the target's air content defined as the air/planning target volume (PTV) in percent (air/PTV) was varied. VMAT plans were recalculated by AAA and AXB with the same monitor unit (MU) and multi-leaf collimator (MLC) motions. The dose at each air/PTV (5%-30%) was compared between each algorithm with D98%, D95%, D50% and D2% for the PTV. In addition, MUs were also compared with the same MLC motions between the D95% prescription with AAA (AAA_D95%), AXB_D95%, and the prescription to 100% minus air/PTV (AXB_D100%-air/PTV) in clinical cases of head and neck (HNC). Results: When air/PTV increased (5-30%), the dose differences between AAA and AXB for D98%, D95%, D50% and D2% were 3.08-15.72%, 2.35-13.92%, 0.63-4.59%, and 0.14-6.44%, respectively. At clinical cases with air/PTV of 5.61% and 28.19%, compared to AAA_D95%, the MUs differences were, respectively, 2.03% and 6.74% for AXB_D95% and 1.80% and 0.50% for AXB_D100%-air/PTV. Conclusion: The dose difference between AAA and AXB increased as the target's air content increased, and AXB_D95% resulted in a dose escalation over AAA_D95% when the target's air content was ≥ 5%. The D100%-air/PTV of PTV using AXB was comparable to the D95% of PTV using AAA.

4.
J Pharm Pharm Sci ; 24: 71-83, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33600308

RESUMEN

PURPOSE: We previously confirmed its anti-atherosclerotic effects by pre-treatment with compound-326, a selective delta-5 desaturase (D5D) inhibitor, in Western diet-fed ApoE knockout mice. In the present study, we evaluated effects of compound-326 in ApoE knockout mice with two different protocols for atherosclerosis development. METHODS: In a post-treatment protocol, where the compound treatment started after 10 weeks pre-feeding of Western diet, compound-326 (1 and 3 mg/kg/day, p.o. for 12 weeks) significantly reduced the atherosclerotic lesion area in the aorta (24% reduction at 3 mg/kg/day). In another protocol using Paigen diet (containing 12.5% cholesterol and 5% sodium cholate), compound-326 (3 and 10 mg/kg/day, p.o. for 7 weeks) also significantly reduced the lesion area (36% reduction at 3 mg/kg/day). RESULTS: In both protocols, Compound-326 significantly reduced the hepatic ratio of arachidonic acid to dihomo-γ-linolenic acid, blood inflammatory eicosanoid production and plasma soluble intercellular adhesion molecule 1 (sICAM-1) levels, similarly to the previous pre-treatment study. CONCLUSIONS: Compound-326 exerted anti-atherosclerotic effects in ApoE knockout mice with the two different protocols for atherosclerosis development further supporting D5D inhibition as a promising strategy in treating atherosclerosis.


Asunto(s)
Aterosclerosis/tratamiento farmacológico , Inhibidores Enzimáticos/farmacología , Ácido Graso Desaturasas/antagonistas & inhibidores , Animales , Aterosclerosis/metabolismo , Aterosclerosis/patología , delta-5 Desaturasa de Ácido Graso , Relación Dosis-Respuesta a Droga , Inhibidores Enzimáticos/química , Ácido Graso Desaturasas/metabolismo , Masculino , Ratones , Ratones Noqueados para ApoE
5.
J Appl Clin Med Phys ; 22(9): 113-122, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34338435

RESUMEN

PURPOSE: The purpose of this study was to compare the dose-volume parameters and regression scatter plots of the iteratively improved RapidPlan (RP) models, specific knowledge-based planning (KBP) models, in volumetric-modulated arc therapy (VMAT) for prostate cancer over three periods. METHODS: A RP1 model was created from 47 clinical intensity-modulated radiation therapy (IMRT)/VMAT plans. A RP2 model was created to exceed dosimetric goals which set as the mean values +1SD of the dose-volume parameters of RP1 (50 consecutive new clinical VMAT plans). A RP3 model was created with more strict dose constraints for organs at risks (OARs) than RP1 and RP2 models (50 consecutive anew clinical VMAT plans). Each RP model was validated against 30 validation plans (RP1, RP2, and RP3) that were not used for model configuration, and the dose-volume parameters were compared. The Cook's distances of regression scatterplots of each model were also evaluated. RESULTS: Significant differences (p < 0.05) between RP1 and RP2 were found in Dmean (101.5% vs. 101.9%), homogeneity index (3.90 vs. 4.44), 95% isodose conformity index (1.22 vs. 1.20) for the target, V40Gy (47.3% vs. 45.7%), V60Gy (27.9% vs. 27.1%), V70Gy (16.4% vs. 15.2%), and V78Gy (0.4% vs. 0.2%) for the rectal wall, and V40Gy (43.8% vs. 41.8%) and V70Gy (21.3% vs. 20.5%) for the bladder wall, whereas only V70Gy (15.2% vs. 15.8%) of the rectal wall differed significantly between RP2 and RP3. The proportions of cases with a Cook's distance of <1.0 (RP1, RP2, and RP3 models) were 55%, 78%, and 84% for the rectal wall, and 77%, 68%, and 76% for the bladder wall, respectively. CONCLUSIONS: The iteratively improved RP models, reflecting the clear dosimetric goals based on the RP feedback (dose-volume parameters) and more strict dose constraints for the OARs, generated superior dose-volume parameters and the regression scatterplots in the model converged. This approach could be used to standardize the inverse planning strategies.


Asunto(s)
Neoplasias de la Próstata , Radioterapia de Intensidad Modulada , Humanos , Masculino , Órganos en Riesgo , Neoplasias de la Próstata/radioterapia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
6.
Bioorg Med Chem ; 28(7): 115376, 2020 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-32088125

RESUMEN

Sphingomyelin synthase 2 (SMS2) has attracted attention as a drug target for the treatment of various cardiovascular and metabolic diseases. The modification of a high throughput screening hit, 2-quinolone 10, enhanced SMS2 inhibition at nanomolar concentrations with good selectivity against SMS1. To improve the pharmaceutical properties such as passive membrane permeability and aqueous solubility, adjustment of lipophilicity was attempted and 1,8-naphthyridin-2-one 37 was identified as a potent and selective SMS2 inhibitor. A significant reduction in hepatic sphingomyelin levels following repeated treatment in mice suggested that compound 37 could be an effective in vivo tool for clarifying the role of SMS2 enzyme and developing the treatment for SMS2-related diseases.


Asunto(s)
Transferasas (Grupos de Otros Fosfatos Sustitutos)/antagonistas & inhibidores , Animales , Línea Celular , Descubrimiento de Drogas , Inhibidores Enzimáticos , Humanos , Masculino , Ratones
7.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 76(10): 1009-1016, 2020.
Artículo en Japonés | MEDLINE | ID: mdl-33087646

RESUMEN

PURPOSE: The purpose of this paper was to determine the optimal imaging conditions for four-dimensional cone-beam computed tomography (4D-CBCT) using an X-ray tube and a flat-panel detector mounted on a radiotherapy device. METHODS: The optimal imaging conditions were examined by changing the gantry speed (GS) parameter that affected the exposure time. Exposed dose during imaging and image quality of moving phantom were compared between examined conditions. RESULTS: The weighted computed tomography dose index (CTDIW) decreased linearly with increasing GS. However, when GS was 180°/min or faster, the image quality degraded, and errors of 1 mm or more were observed regarding the size of mock tumor in the moving phantom. The accuracy of automatic image matching was within 0.1 mm when GS of 120°/min or slower was chosen. CONCLUSION: From the results of this study, we concluded that GS of 120°/min is the optimum imaging condition. Under this imaging condition, the exposure time and CTDIW can be reduced by about 50% without compromising the accuracy of image registration, compared to the conventional GS of 70°/min. In addition, it has been clarified that there is an event that image reconstruction is not performed correctly due to the influence of phantom artifacts without depending on GS.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Tomografía Computarizada Cuatridimensional , Artefactos , Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen
8.
J Pharmacol Exp Ther ; 371(2): 290-298, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31488602

RESUMEN

Delta-5 desaturase (D5D), encoded by fatty acid desaturase 1 (Fads1), is the rate-limiting enzyme for the conversion from dihomo-γ-linolenic acid (DGLA) to arachidonic acid (AA) in the ω-6 polyunsaturated fatty acid pathway. Several AA-derived eicosanoids (e.g., prostaglandins, thromboxanes, and leukotrienes) and DGLA-derived eicosanoids are reported to promote and/or prevent atherosclerosis progression through, at least in part, its proinflammatory or anti-inflammatory effects. To elucidate the effects of D5D inhibition by a D5D inhibitor on atherosclerosis, we generated a potent, orally available and selective D5D inhibitor, 2-(2,2,3,3,3-Pentafluoropropoxy)-3-[4-(2,2,2-trifluoroethoxy) phenyl]-5,7-dihydro-3H-pyrrolo[2,3-d]pyrimidine-4,6-dione, compound-326, and examined its effects on Western-diet fed ApoE knockout (KO) mice. Oral administration of compound-326 (3-10 mg/kg per day for 15 weeks) significantly inhibited the progression of atherosclerotic lesions in the aorta without affecting plasma total cholesterol and triglyceride levels. Compound-326 significantly decreased AA levels, while it increased DGLA levels in the liver and the blood accompanied by decreases in AA-derived eicosanoid production and increases in DGLA-derived eicosanoid production from the blood cells. We conclude that compound-326 prevents the progression of atherosclerosis in Western-diet fed ApoE KO mice by modulating a profile of eicosanoid production, suggesting that D5D inhibitors can be a novel remedy for preventing atherosclerosis and subsequent cardiovascular events. SIGNIFICANCE STATEMENT: This study shows a D5D-specific and orally available potent inhibitor provided the first evidence to support the concept that D5D inhibitors will be a novel remedy for preventing the progression of atherosclerosis.


Asunto(s)
Aterosclerosis/tratamiento farmacológico , Aterosclerosis/metabolismo , Eicosanoides/biosíntesis , Ácido Graso Desaturasas/antagonistas & inhibidores , Ácido Graso Desaturasas/metabolismo , Ácidos Grasos/metabolismo , Administración Oral , Animales , delta-5 Desaturasa de Ácido Graso , Relación Dosis-Respuesta a Droga , Inhibidores Enzimáticos/farmacología , Inhibidores Enzimáticos/uso terapéutico , Masculino , Ratones , Ratones Endogámicos C57BL , Ratones Noqueados , Ratones Noqueados para ApoE
9.
Rep Pract Oncol Radiother ; 24(6): 600-605, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31660052

RESUMEN

AIM: To evaluate the success of a patient-specific intensity modulated radiation therapy (IMRT) quality assurance (QA) practice for prostate cancer patients across multiple institutions using a questionnaire survey. BACKGROUND: The IMRT QA practice involves different methods of dose distribution verification and analysis at different institutions. MATERIALS AND METHODS: Two full-arc volumetric modulated arc therapy (VMAT) plan and 7 fixed-gantry IMRT plan with DMLC were used for patient specific QA across 22 institutions. The same computed tomography image and structure set were used for all plans. Each institution recalculated the dose distribution with fixed monitor units and without any modification. Single-point dose measurement with a cylindrical ionization chamber and dose distribution verification with a multi-detector or radiochromic film were performed, according to the QA process at each institution. RESULTS: Twenty-two institutions performed the patient-specific IMRT QA verifications. With a single-point dose measurement at the isocenter, the average difference between the calculated and measured doses was 0.5 ±â€¯1.9%. For the comparison of dose distributions, 18 institutions used a two or three-dimensional array detector, while the others used Gafchromic film. In the γ test with dose difference/distance-to-agreement criteria of 3%-3 mm and 2%-2 mm with a 30% dose threshold, the median gamma pass rates were 99.3% (range: 41.7%-100.0%) and 96.4% (range: 29.4%-100.0%), respectively. CONCLUSION: This survey was an informative trial to understand the verification status of patient-specific IMRT QA measurements for prostate cancer. In most institutions, the point dose measurement and dose distribution differences met the desired criteria.

10.
J Appl Clin Med Phys ; 19(2): 121-127, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29368420

RESUMEN

It is important to improve the magnitude of dose variation that is caused by the interplay effect. The aim of this study was to investigate the impact of the number of breaths (NBs) to the dose variation for VMAT-SBRT to lung cancer. Data on respiratory motion and multileaf collimator (MLC) sequence were collected from the cases of 30 patients who underwent radiotherapy with VMAT-SBRT for lung cancer. The NBs in the total irradiation time with VMAT and the maximum craniocaudal amplitude of the target were calculated. The MLC sequence complexity was evaluated using the modulation complexity score for VMAT (MCSv). Static and dynamic measurements were performed using a cylindrical respiratory motion phantom and a micro ionization chamber. The 1 standard deviation which were obtained from 10 dynamic measurements for each patient were defined as dose variation caused by the interplay effect. The dose distributions were also verified with radiochromic film to detect undesired hot and cold dose spot. Dose measurements were also performed with different NBs in the same plan for 16 patients in 30 patients. The correlations between dose variations and parameters assessed for each treatment plan including NBs, MCSv, the MCSv/amplitude quotient (TMMCSv), and the MCSv/amplitude quotient × NBs product (IVS) were evaluated. Dose variation was decreased with increasing NBs, and NBs of >40 times maintained the dose variation within 3% in 15 cases. The correlation between dose variation and IVS which were considered NBs was shown stronger (R2  = 0.43, P < 0.05) than TMMCSv (R2  = 0.32, P < 0.05). The NBs is an important factor to reduce the dose variation. The patient who breathes >40 times during irradiation of two partial arcs VMAT (i.e., NBs = 16 breaths per minute) may be suitable for VMAT-SBRT for lung cancer.


Asunto(s)
Algoritmos , Neoplasias Pulmonares/cirugía , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Planificación de la Radioterapia Asistida por Computador/normas , Radioterapia de Intensidad Modulada/métodos , Humanos , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/radioterapia , Movimiento (Física) , Pronóstico , Dosificación Radioterapéutica , Respiración
11.
J Appl Clin Med Phys ; 18(3): 44-51, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28383157

RESUMEN

We developed a novel low-radiation-absorbent lok-bar (HM-bar) that is used to secure the immobilizers to the couch. The aim of this study was to investigate the X-ray scattering and absorption properties of the HM-bar in computed tomography (CT) simulation and radiotherapy dose delivery using the Varian Exact™ lok-bar (VL-bar) as a benchmark. CT images were obtained with or without lok-bar, and then each image was visually evaluated for artifacts. The attenuation rates for each lok-bar were measured using a farmer-type ionization chamber (PTW30013) and the I'mRT phantom (IBA Dosimetry GmbH). Measurement points were between gantry angles of 110 and 180°. The treatment apparatus was a NovalisTx (Brainlab AG); X-ray energies were set at 6 MV and 10 MV. In the presence of each lok-bar, the radiation dose was measured in accordance with 10 volumetric modulated arc therapy-stereotactic body radiation therapy (VMAT-SBRT) plans for lung cancer. Artifacts were seldom observed in the CT scans of the HM-bar. The attenuation rate of each lok-bar was higher when the X-ray energy was set at 6 MV than at 10 MV. The highest attenuation rate in the VL-bar was observed at a gantry angle of 112°; the rates were 22.4% at 6 MV and 19.3% at 10 MV. Similarly, the highest attenuation rate for the HM-bar was also observed at a gantry angle of 112°; the rates were 12.2% and 10.1% at 6 MV and 10 MV, respectively. When the VL-bar was evaluated, the isocenter dose of the VMAT-SBRT plans was attenuated by 2.6% as a maximum case. In the case of the HM-bar, the maximum attenuation was 1.4%. In the measurements of each VMAT-SBRT plan, the difference of the dose attenuation rate between the VL-bar and HM-bar was approximately 1%. The HM-bar could be used to minimize the occurrence of artifacts and provide good images in CT scans regarding radiotherapy planning and dose calculation. It can be used for patient therapy at hospitals to provide accurate dose delivery because of its low X-ray scattering and absorption characteristics.


Asunto(s)
Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada/instrumentación , Radioterapia de Intensidad Modulada/métodos , Dispersión de Radiación , Benchmarking , Humanos , Fantasmas de Imagen , Radiocirugia/instrumentación , Dosificación Radioterapéutica , Rayos X
12.
Phys Rev Lett ; 110(12): 127201, 2013 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-25166836

RESUMEN

A spin battery concept is applied for the dynamical generation of pure spin current and spin transport in p-type silicon (p-Si). Ferromagnetic resonance and effective s-d coupling in Ni(80)Fe(20) results in spin accumulation at the Ni(80)Fe(20)/p-Si interface, inducing spin injection and the generation of spin current in the p-Si. The pure spin current is converted to a charge current by the inverse spin Hall effect of Pd evaporated onto the p-Si. This approach demonstrates the generation and transport of pure spin current in p-Si at room temperature.

13.
Cureus ; 15(3): e36493, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37090359

RESUMEN

This study aims to determine the feasibility of using a new O-ring linear accelerator (Halcyon, Varian Medical Systems, CA, USA) to perform treatment planning using volumetric modulated arc therapy (VMAT) for craniospinal irradiation (CSI). A 20-year-old male patient with leukemia was selected. The planning target volume (PTV) was contoured to include the entire contents of the brain and spinal canal. The PTV margin was 10 mm applied to the clinical target volume (CTV). VMAT (RapidArc, Varian Medical Systems, CA, USA) planning was performed using four isocenter with five arcs, two full rotation arcs to cover the brain and upper part of the spinal cord, and one full rotation arc for the lower part of the spinal cord. The plan was created using the auto-feathering photon optimizer calculation of the planning system. The conformity index (CI) and heterogeneity index (HI) as well as dose-volume histograms of organs at risk (OAR) were evaluated. The patient position of ±3.0 mm in the craniocaudal direction was moved in to simulate the effect of treatment inaccuracy. The total treatment time was also measured. The CI and HI were 1.09 and 8.44, respectively. The mean dose (PTV) was 105.5%, and the mean dose (OARs) was lower than the planning dose constraints. Simulations with a patient position shift of ±3.0 mm resulted in an error of less than ±10.0% of the planned dose to the spinal cord. The total treatment time was within 15 minutes. VMAT planning for CSI with Halcyon achieved high conformality, uniform dose distribution, low dose to the surrounding normal tissues, and reduced treatment time.

14.
Cureus ; 15(1): e34287, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36843808

RESUMEN

Background Coronavirus disease 2019 and other viruses are transmissible by aerosols and droplets from infected persons. This study aimed to develop a portable device that can trap droplets and deactivate viruses, and verify whether the device in an enclosed room can suction droplets and sanitize them using a filter and an ultraviolet-C (UVC) light-emitting diode. Materials and methods The portable device was evaluated by placing it 50 cm away from the droplet initiation point. A particle image velocimetry laser dispersed into a sheet form was used to visualize the droplets splashed on the irradiated sagittal plane and captured using a charge-coupled device camera at 60 frames per second. The images were overlaid and calculated to determine the percentage of the droplets beyond the portable device. Droplets with a particle size larger than 50 µm that dispersed and were deposited more than 100 cm away were measured using a water-sensitive paper. The effect of UVC sanitization on viruses captured by a high-efficiency particulate air (HEPA) filter was determined using a plaque assay. Results The percentage of droplets was 13.4% and 1.1% with the portable device OFF and ON, respectively, indicating a 91.8% reduction. The deposited droplets were 86 pixels and 26 pixels with the portable device OFF and ON, respectively, indicating a 68.7% reduction. The UVC deactivated more than 99% of the viruses on the HEPA filter surface in 5 minutes. Conclusions Our novel portable device can suck and fall the dispersed droplets, and an active virus was not observed on the exhaust side.

15.
Ann Nucl Med ; 37(11): 629-634, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37596439

RESUMEN

OBJECTIVE: The purpose of this study is to determine the dose reduction of different shielding materials at various distances from a 177Lu photon radiation source. METHODS: Two protective aprons with lead equivalent thicknesses of 0.25 mm and 0.35 mm and tungsten-containing rubber (TCR) were used as shielding materials. A vial containing 177Lu was sealed in a lead container so that a narrow beam went out through a 3 mm-diameter hole. The dose rate was measured at distances of 0, 10, 50, 100, and 200 cm from the source using a NaI scintillation survey meter to obtain the rate of dose reduction. TCR was tested with thicknesses ranging from 0.3 to 1.0 mm at 0.1 mm intervals and from 1.0 to 4.0 mm at 0.5 mm intervals. RESULTS: At distances of 0, 10, 50, 100, and 200 cm, the dose reduction for the lead equivalent thickness of 0.25 mm were 32.7%, 54.5%, 93.1%, 97.9%, and 99.6%, respectively; and for the lead equivalent thickness of 0.35 mm were 53.4%, 70.6%, 95.6%, 98.9%, and 99.6%, respectively. Without any shielding, the dose rate decreased by 34.4% at 10 cm and by 88.8% at 50 cm from the radiation source. The dose reduction for the TCR thickness of 3.5 mm was 89.8% at 0 cm and 93.3% at 10 cm. The TCR thickness of 0.4 mm provided a dose reduction comparable to or greater than that of the 0.25 mm lead equivalent, whereas the TCR thickness of 1.0 mm or greater provided a dose reduction comparable to that of the 0.35 mm lead equivalent. CONCLUSIONS: Achieving a reduction of 95% or more requires the 0.25 mm lead equivalent for a distance of 100 cm, the 0.35 mm lead equivalent for 50 cm, the TCR thickness of 0.3 mm for 100 cm, or the TCR thickness of 0.9 mm for 50 cm. Without wearing a protective apron, a reduction of approximately 95% is observed at distances greater than 100 cm. These findings would be useful for medical staff engaging in related activities.

16.
Phys Eng Sci Med ; 46(3): 1091-1100, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37247102

RESUMEN

PURPOSE: To evaluate whether knowledge-based volumetric modulated arc therapy plans for prostate cancer with a multi-institution model (broad model) are clinically useful and effective as a standardization method. METHODS: A knowledge-based planning (KBP) model was trained with 561 prostate VMAT plans from five institutions with different contouring and planning policies. Five clinical plans at each institution were reoptimized with the broad and single institution model, and the dosimetric parameters and relationship between Dmean and the overlapping volume (rectum or bladder and target) were compared. RESULTS: The differences between the broad and single institution models in the dosimetric parameters for V50, V80, V90, and Dmean were: rectum; 9.5% ± 10.3%, 3.3% ± 1.5%, 1.7% ± 1.6%, and 3.6% ± 3.6%, (p < 0.001), bladder; 8.7% ± 12.8%, 1.5% ± 2.6%, 0.7% ± 2.4%, and 2.7% ± 4.6% (p < 0.02), respectively. The differences between the broad model and clinical plans were: rectum; 2.4% ± 4.6%, 1.7% ± 1.7%, 0.7% ± 2.4%, and 1.5% ± 2.0%, (p = 0.004, 0.015, 0.112, and 0.009) bladder; 2.9% ± 5.8%, 1.6% ± 1.9%, 0.9% ± 1.7%, and 1.1% ± 4.8%, (p < 0.018), respectively. Positive values indicate that the broad model has a lower value. Strong correlations were observed (p < 0.001) in the relationship between Dmean and the rectal and bladder volume overlapping with the target in the broad model (R = 0.815 and 0.891, respectively). The broad model had the smallest R2 of the three plans. CONCLUSIONS: KBP with the broad model is clinically effective and applicable as a standardization method at multiple institutions.


Asunto(s)
Neoplasias de la Próstata , Radioterapia de Intensidad Modulada , Masculino , Humanos , Próstata , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Estándares de Referencia
17.
Phys Med Biol ; 68(10)2023 05 05.
Artículo en Inglés | MEDLINE | ID: mdl-36972591

RESUMEN

Objective.The purpose of this study was to develop a new bolus (HM bolus), with tissue equivalence, transparency, reusability, and free shaping at approximately 40 °C for excellent adhesion, and to evaluate the feasibility of clinically using this bolus as an ideal bolus.Approach.We summarized the advantages and disadvantages of existing boluses. To evaluate dose characteristics, a vinyl gel sheet bolus (Gel bolus) and HM bolus placed on a water-equivalent phantom were used to obtain the percentage depth dose (PDD) of electron (6 MeV, 9 MeV) and photon (4 MV, 6 MV) beams. The average dose difference of the HM bolus and Gel bolus was calculated. The Gel bolus, a soft rubber bolus (SR bolus), and HM bolus were placed in adherence to a pelvic phantom. CT images taken after shaping and 1, 2, and 3 weeks after shaping were used to evaluate the adhesion and reproducibility using air gap and dice similarity coefficient (DSC).Main results.The average dose difference for electron beams was 0.16% ± 0.79% and photon beams was 0.06% ± 0.34%, both within 1% of the PDD results. The HM bolus showed the same build-up effect and dose characteristics as the Gel bolus. The mean air gap values for the Gel bolus, SR bolus, and HM bolus were 96.02 ± 43.77 cm3, 34.93 ± 21.44 cm3, and 4.40 ± 1.50 cm3, respectively. The mean DSC values compared to initial images for the Gel bolus, SR bolus, and HM bolus were 0.363 ± 0.035, 0.556 ± 0.042, and 0.837 ± 0.018, respectively. Excellent adhesion was observed in the CT simulation and during the treatment period.Significance.The HM bolus has unique features, such as tissue equivalence, transparency, reusability, and free shaping for excellent adhesion, and is thus an ideal bolus for use in clinical cases.


Asunto(s)
Fotones , Planificación de la Radioterapia Asistida por Computador , Reproducibilidad de los Resultados , Método de Montecarlo , Planificación de la Radioterapia Asistida por Computador/métodos , Simulación por Computador , Fantasmas de Imagen , Dosificación Radioterapéutica , Radiometría/métodos , Radioterapia
18.
Cureus ; 15(10): e46805, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37954761

RESUMEN

BACKGROUND: To compare the doses calculated by the analytical anisotropic algorithm (AAA) and two dose reporting modes of Acuros XB (AXB(Dm) and AXB(Dw)) with varied CT values on the Eclipse (Varian Medical Systems, Palo Alto, CA). MATERIALS AND METHODS: Virtual phantoms with a central layer of heterogeneous material (thickness = 2 or 5 cm) were created with Eclipse. Using single or opposed fields, the field sizes were 5 x 5 cm2 or 10 x 10 cm2. The photon energies were 6 or 10 MV, and the source-to-target distance was 100 cm. The relative doses at the center of the heterogeneous material layer were evaluated with varied CT values, from -1000 to 3000 HU. Values were normalized with the dose at 0 HU (100%) for comparative analysis. RESULTS: The results obtained from continuous data for a single field, 6 MV, 5 x 5 cm2, and the heterogeneous material 5 cm, where the differences between algorithms were most pronounced, were as follows. In the low-density region (-1000 HU and -800 HU), the dose differences for AXB with reference to AAA were, respectively, -54.5% and +4.6% (AXB(Dm)) and -47.0% and +3.5% (AXB(Dw)), and in the high-density regions (1000 HU and 3000 HU) were -5.7% and -8.8% (AXB(Dm)) and +7.4% and +3.5% (AXB(Dw)), respectively. Consequently, dose differences at arbitrary CT values could be obtained. CONCLUSION: Dose differences between these algorithms were clarified for heterogeneous materials. The risk of dose reduction or escalation in clinical use was clearly visible between CT values from -1000 to 3000 HU.

19.
J Med Phys ; 48(4): 365-372, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38223796

RESUMEN

Purpose: The purpose of the study is to investigate the impact of large target offset distances on the dose distribution and gamma passing rate (GPR) in single-isocenter multiple-target stereotactic radiosurgery (SIMT SRS) using volumetric modulated arc therapy (VMAT) with a flattening filter-free (FFF) beam from a linear accelerator. Methods: Two targets with a diameter of 1 cm were offset by "±2, ±4, and ±6 cm from the isocenter in a verification phantom for head SRS (20 Gy/fr). The VMAT plans were created using collimator angles that ensured the two targets did not share a leaf pair from the multi-leaf collimator. To evaluate the low-dose spread intermediate dose spill (R50%), GPRs were measured with a criterion of 3%/2 mm using an electronic portal imaging device and evaluated using monitor unit (MU), modulation complexity score for VMAT (MCSv), and leaf travel (LT) parameters. Results: For offsets of 2, 4, and 6 cm, the respective parameters were: R50%, 4.75 ± 0.36, 5.13 ± 0.36, and 5.11 ± 0.33; GPR, 95.01%, 93.82%, and 90.67%; MU, 5893 ± 186, 5825 ± 286, and 5810 ± 396; MCSv, 0.24, 0.16, and 0.13; and LT, 189.21 ± 36.04, 327.69 ± 67.01, and 430.39 ± 114.34 mm. There was a spread in the low-dose region from offsets of ≥4 cm and the GPR negatively correlated with LT (r = -0.762). There was minimal correlation between GPR and MU or MCSv. Conclusions: In SIMT SRS VMAT plans with an FFF beam from a linear accelerator, target offsets of <4 cm from the isocenter can minimize the volume of the low-dose region receiving 10 Gy or more. During treatment planning, it is important to choose gantry, couch, and collimator angles that minimize LT and thereby improve the GPR.

20.
Anticancer Res ; 43(5): 1967-1972, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37097686

RESUMEN

BACKGROUND/AIM: This study compared two types of parallel-plate ionization chamber to clarify the pitfalls of dosimetry in electron radiation therapy. MATERIALS AND METHODS: The ion recombination correction factor and polarity effect correction factor, sensitivity, and percentage depth doses (PDDs) of PPC05 and PPC40 parallel-plate ionization chambers were compared in a small-field electron beam. The output ratios were measured for 4-20 MeV electron beams with field sizes of 10 cm × 10 cm, 6 cm × 6 cm, and 4 cm × 4 cm. Furthermore, the films were placed in water and positioned in the beam with their surface perpendicular to the beam axis, and lateral profiles were obtained for each beam energy and each field. RESULTS: Regarding PDDs, at depths greater than the peak dose, the percentage depth dose for PPC40 was smaller than that for PPC05 in small fields and at beam energies greater than 12 MeV, which could be attributed to the lack of lateral electron equilibrium at small depths and multiple scattering events at large depths. The output ratio of PPC40 was approximately 0.025-0.038, which was lower than that of PPC05 in a 4 cm × 4 cm field. For large fields, the lateral profiles were similar, regardless of the beam energy, however, for small fields, the flatness of the lateral profile was beam energy dependent. CONCLUSION: The PPC05 chamber, which has a smaller ionization volume, is therefore more suitable than the PPC40 chamber for small-field electron dosimetry, in particular at high beam energies.


Asunto(s)
Electrones , Radiometría , Humanos , Agua