RESUMEN
AIM AND BACKGROUND: To compare the root canal volume in primary teeth using hand and rotary instruments and to evaluate root canal filling techniques and flow of root canal obturation materials in the postinstrumented root canal volume using spiral computed tomography (SCT). MATERIALS AND METHODS: Freshly extracted 16 primary molars were randomly divided into two groups and subjected to SCT analysis before and after instrumentation. For the manual technique (group I) with eight teeth were prepared using K files, and rotary (group II) eight teeth preparation was performed with ProTaper files. The filled volume in each canal was measured using SCT, and the percentage of obturated volume was calculated. The data were statistically analyzed using the Mann-Whitney U test. RESULTS: There was a statistically significant difference in both groups' volume of root canals enlarged. Even though both K files and the ProTaper system brought about enlarged canals after instrumentation, there was a statistically significant increase in volume after using K files in two canals. In three canals, there was a statistically significant increase in volume after using ProTaper. Irrespective of the obturation technique and materials used, there is no statistically significant difference in the volume after obturation. CONCLUSION: From the results of this study, the ProTaper file system shows suitable volumetric enlargement up to an optimum level, which is needed in primary root canal walls, and is better in canal shaping, as evidenced by good postobturation volume. CLINICAL SIGNIFICANCE: The traditional method of cleaning and shaping the root canals in permanent teeth using manual stainless-steel files can lead to undesirable curvatures in root canal morphology, making correctly filling the root canals difficult. It is also time-consuming and sometimes leads to iatrogenic errors. Rotary nickel-titanium (Ni-Ti) instrumentation techniques have been developed to overcome these problems. How to cite this article: Yadav DBUC, Varma RB, Kumar JS, et al. Volumetric Analysis of Hand and Rotary Instrumentation, Root Canal Filling Techniques, and Obturation Materials in Primary Teeth Using Spiral CT. J Contemp Dent Pract 2024;25(3):250-259.
Asunto(s)
Cavidad Pulpar , Diente Molar , Materiales de Obturación del Conducto Radicular , Obturación del Conducto Radicular , Preparación del Conducto Radicular , Tomografía Computarizada Espiral , Diente Primario , Humanos , Obturación del Conducto Radicular/métodos , Diente Primario/diagnóstico por imagen , Preparación del Conducto Radicular/instrumentación , Preparación del Conducto Radicular/métodos , Cavidad Pulpar/diagnóstico por imagen , Cavidad Pulpar/anatomía & histología , Tomografía Computarizada Espiral/métodos , Diente Molar/diagnóstico por imagen , Instrumentos Dentales , Técnicas In VitroRESUMEN
Stickler syndrome or hereditary progressive arthro-ophthalmopathy is an autosomal dominant condition characterized by ocular manifestations, arthritic changes, orofacial features, and deafness, in variable degrees. This is a case report of a 48-day-old infant who presented with severe feeding difficulty. It also details the clinical, diagnostic features, and management of an infant with Stickler syndrome.
RESUMEN
Arteriovenous fistula (AVF) is the most appropriate vascular access for all chronic kidney disease patients for hemodialysis. However, patients with diabetic nephropathy are at increased risk for primary failure after AVF creation, mainly due to atherosclerosis and calcification of blood vessels. We conducted this study to find out the risk factors for primary failure of radiocephalic AVF in end-stage renal disease (ESRD) patients due to diabetic nephropathy and develop a risk predicting model. This study was conducted at a tertiary care teaching hospital of South India. Patients with ESRD due to diabetic nephropathy whom underwent left radiocephalic AVF at wrist were enrolled. Risk factors for primary failure were analyzed by univariate and multivariate logistic regression models. Sixty-six patients were included in the study. Thirty-one patients had a primary failure. Independent risk factors for primary failure were palpable vessel wall of the radial artery (P = 0.003, odds ratio [OR] = 15.317), smaller radial artery diameter (P = 0.001, OR = 16.526), radial artery peak systolic velocity (PSV) <45 cm/s (P = 0.005, OR = 8.494), and linear radial artery calcification (P = 0.006, OR = 7.942). The risk predicting model obtained by adding the score given for each risk factors (vessel wall not palpable = 0, palpable = 1, no linear calcification in digital X-ray = 0, linear calcification = 1, PSV ≥45 cm/s = 0, <45 cm/s = 1 and 2.5 - radial artery diameter in mm) had an area under receiver-operating characteristic curve of 0.886. Cutoff score of 1.5 had sensitivity of 83.9% and specificity of 80.0% for primary failure. Risk predicting model for primary failure based on condition of the vessel wall on palpation, radial artery diameter, flow velocity, and calcification may be helpful for suitable patient selection.
Asunto(s)
Derivación Arteriovenosa Quirúrgica , Técnicas de Apoyo para la Decisión , Nefropatías Diabéticas/terapia , Fallo Renal Crónico/terapia , Arteria Radial/cirugía , Diálisis Renal , Extremidad Superior/irrigación sanguínea , Venas/cirugía , Adulto , Anciano , Derivación Arteriovenosa Quirúrgica/efectos adversos , Toma de Decisiones Clínicas , Nefropatías Diabéticas/diagnóstico , Nefropatías Diabéticas/etiología , Femenino , Humanos , India , Fallo Renal Crónico/diagnóstico , Fallo Renal Crónico/etiología , Masculino , Persona de Mediana Edad , Selección de Paciente , Valor Predictivo de las Pruebas , Medición de Riesgo , Factores de Riesgo , Resultado del TratamientoRESUMEN
AIM: To evaluate and compare the efficacy of "calcium sucrose phosphate" (CaSP) toothpaste (Enafix 5%) with ordinarily used calcium, phosphate-containing toothpaste in elevating the level of calcium, phosphate ions in saliva. Secondary aims were to evaluate substantivity and plaque-reducing ability of CaSP toothpaste. MATERIALS AND METHODS: Thirty study participants of age group 6-13 years were divided into two groups: Group X (Control group) was made to continue brushing with their regularly used calcium, phosphate-containing toothpaste and Group Y (Test group) was allotted CaSP toothpaste. 1 ml of unstimulated saliva was periodically collected from both groups to determine any alteration in the salivary calcium, phosphate level. Parameters such as substantivity and plaque-reducing ability of CaSP toothpaste were also evaluated. Salivary mineral's intergroup comparison was evaluated by Student's t-test while its intragroup comparison along with the plaque amount variation in Group Y was evaluated by ANOVA and Tukey's post hoc test. RESULTS: Group Y showed an increase in the salivary calcium level though not statistically significant. The increase was pronounced in samples collected on day 1. Group Y showed a consistent level of calcium, phosphate in samples collected immediately and 6 h postbrushing, indicating its substantivity. In addition, Group Y had an impact in reducing the plaque level when the 1st-month plaque score was compared with the 12th-month score. CONCLUSION: CaSP leads to an increase in the salivary calcium level though it was not statistically significant. Supervised brushing and dietary habits showed a positive effect on both the groups. CaSP toothpaste also showed substantivity and plaque-reducing ability.
RESUMEN
A BaCO3/BaSnO3/SnO2 nanocomposite has been prepared using a co-precipitation method without adding any additives. The prepared sample was characterized by using X-ray diffraction (XRD), high-resolution transmission electron microscopy (HRTEM), scanning electron microscopy (SEM), Fourier-transform infrared (FT-IR) spectroscopy, energy dispersive X-ray spectroscopy (EDS) and Raman spectroscopy. Detailed studies on the dielectric and electrical behavior (dielectric constant, complex impedance Z*, ac conductivity, and relaxation mechanisms) of the nanocomposite have been performed using the nondestructive complex impedance spectroscopy technique within the temperature range 150-400 K. The dielectric constant of the sample as a function of temperature showed the typical characteristics of a relaxor. The maximum dielectric constant value was observed to depend on frequency. The non-monotonic relaxation behavior of the prepared nanocomposite was evidenced from the spectra of loss tan, tan(δ). The relaxation kinetics was modeled using a non-Arrhenius model.
RESUMEN
Ectodermal dysplasia is a heterogeneous group of inherited disorders, which exhibit a classic triad of hypohydrosis, hypotrichosis, and hypodontia. Hypohidrotic or anhidrotic ectodermal dysplasia or Christ Siemens Touraine syndrome is the most common condition among ectodermal dysplasia patients. This is a case report on two Christ Siemens Touraine syndrome cases and two different approaches to prosthetic management.