Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Endoscopy ; 56(1): 14-21, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37769690

RESUMEN

BACKGROUND: Cold snare defect protrusions (CSDPs) that occur after cold snare polypectomy (CSP) are considered indicators of incomplete polyp resection (IPR). We have sometimes experienced difficulty resecting polyps with snaring alone; in such cases, a forcible pull on the snare by the endoscopist is necessary. We call this procedure "forced CSP (FCSP)." However, no previous studies have evaluated this procedure. METHODS: This was a prospective observational study. From November 2020 to June 2021, the frequency, safety, and validity of FCSP were evaluated at our hospital. We distinguished CSP with snaring alone performed by the assistant as conventional CSP, and CSP requiring a forcible pull on the snare by the endoscopist as FCSP. RESULTS: Of 1315 polyps removed, 105 underwent FCSP (8%). The perforation rate was 0% in both groups. The rate of CSDP after the procedure was 96.2% (101/105) with FCSP and 6.4% (77/1210) with conventional CSP (P<0.001). The rate of IPR was 12.5% (13/104) with FCSP and 6.2% (75/1208) with conventional CSP (P=0.02). Multivariable analysis identified polyps located in the cecum (risk ratio [RR], 1.13; 95%CI 1.050-1.179; P=0.003) and polyps ≥6mm in diameter (RR, 2.37; 95%CI 2.146-2.542; P<0.001) as independent risk factors for FCSP. CONCLUSIONS: FCSP was performed on 105 polyps (8%) in this study. FCSP may be associated with the occurrence of CSDP and IPR. Further studies are necessary to confirm our results.


Asunto(s)
Pólipos del Colon , Humanos , Pólipos del Colon/cirugía , Colonoscopía/efectos adversos , Colonoscopía/métodos , Microcirugia , Estudios Prospectivos , Factores de Riesgo
2.
Dig Dis ; 42(1): 31-40, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37967542

RESUMEN

INTRODUCTION: Despite advances in endoscopic treatment, patients with serrated polyposis syndrome (SPS) occasionally require surgery due to numerous or unresectable polyps, recurrence, and treatment-related adverse events. METHODS: We retrospectively evaluated 43 patients with SPS undergoing diagnosis and treatment at Omori Red Cross Hospital from 2011 to 2022. Resection of all polyps ≥3 mm in size was planned during the clearing phase; endoscopic control was defined as complete, endoscopic polyp removal. During the surveillance phase, patients underwent annual colonoscopy and resection of newly detected polyps ≥3 mm in size. RESULTS: Thirty-eight patients (88%) achieved endoscopic control, two (5%) required surgery after endoscopic treatment because of colorectal cancer (CRC), and three (7%) have not yet achieved endoscopic control and are planning treatment. Endoscopic control was achieved with a median of four colonoscopies at 8 months. Ten polyps (median value) were resected per patient during the clearing phase. Three polyps ≥50 mm in size, six located in the appendiceal orifice, and seven with severe fibrosis could be resected by endoscopic submucosal dissection (ESD). All patients underwent treatment with a combination of cold snare polypectomy (CSP), endoscopic mucosal resection/hot polypectomy, and/or ESD. No case required surgery due to difficulty with endoscopic treatment. Delayed bleeding was observed in 2 cases (0.3%). Twenty-one patients underwent colonoscopies during the surveillance phase. Fifty-three polyps were resected using CSP; no CRC, sessile serrated lesions with dysplasia, or advanced adenoma were detected. CONCLUSION: SPS can be effectively, efficiently, and safely controlled with appropriate endoscopic management.


Asunto(s)
Poliposis Adenomatosa del Colon , Pólipos del Colon , Neoplasias Colorrectales , Humanos , Pólipos del Colon/diagnóstico , Colonoscopía/efectos adversos , Estudios Retrospectivos , Estudios de Factibilidad , Neoplasias Colorrectales/patología
3.
Dig Dis Sci ; 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38662160

RESUMEN

BACKGROUND: Colorectal ESD, an advanced minimally invasive treatment, presents technical challenges, with globally varying training methods. We analyzed the learning curve of ESD training, emphasizing preoperative strategies, notably gravity traction, to guide ESD instructors and trainee programs. METHOD: This retrospective study included 881 cases guided by an experienced supervisor. Six trainees received "strategy-focused" instruction. To evaluate the number of ESD experiences in steps, the following phases were classified based on ESD experiences of each trainees: Phase 0 (0-50 ESD), Phase 1 (51-100 ESD), Phase 2 (101-150 ESD), and Phase 3 (151-200 ESD). Lesion background, outcomes, and safety were compared across phases. Factors contributing to technical difficulty in early (Phase 0 and 1) and late phases (Phase 2 and 3) were identified, along with the utility of traction ESD with device assistance. RESULT: Treatment outcomes were favorable, with 99.8% and 94.7% en bloc resection and curative resection rates, respectively. Approximately 90% self-completion rate could be achieved after experiencing about 50 cases (92.7% in Phase 1), signifying proficiency growth despite increased case difficulty. In early phases, factors such as left-sided colon, LST-NG morphology, and severe fibrosis pose challenges. In late phases, LST-NG morphology, mild and severe fibrosis remained significant. Traction-assisted ESD, utilized in 3% of cases, comprised planned (1.1%) and rescue (1.9%) methods. Planned traction aided specific lesions, while rescue traction was common in the right colon. CONCLUSION: "Strategy-focused" ESD training consistently yields successful outcomes, effectively adapting to varying difficulty factors in different proficient stages.

4.
Dig Dis Sci ; 69(3): 933-939, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38340260

RESUMEN

BACKGROUND: There is a lack of reports on the use of direct oral anticoagulants (DOACs) during colorectal endoscopic submucosal dissection (ESD). AIMS: We aimed to assess whether the use of DOACs is associated with a higher incidence of delayed bleeding (DB) after ESD. METHODS: A total of 4175 colorectal neoplasms in 3515 patients were dissected at our hospitals during study period. We included 3909 lesions in the final analysis. The lesions were divided into two groups: the no-AT group (3668 neoplasms) and the DOAC group (241 neoplasms). We also compared the DOAC withdrawal group (154 neoplasms) and the DOAC continuation group (87 neoplasms). RESULTS: Among the 3909 lesions, DB occurred in a total of 90 cases (2.3%). The rate of DB was 2.2% (82/3668), and 3.3% (8/241), respectively. There were no significant differences in the rate of DB between the no-AT group and the DOAC group. In the DOAC group, there were no significant differences in the rate of DB between the withdrawal group (5.2%, 8/154) and the continuation group (0%, 0/87). The multivariable analysis identified the location of the lesion in the rectum (odds ratio [OR], 4.04; 95% confidence interval [CI], 2.614-6.242; p < 0.001) and lesions ≥ 30 mm in diameter (OR, 4.14; 95% CI, 2.349-7.34; p < 0.001) as independent risk factors for DB. CONCLUSIONS: Our findings suggest that DOAC use has no significant important on the rate of DB. Prospective studies are warranted to determine whether treatment with DOACs should be interrupted prior to colorectal ESD.


Asunto(s)
Neoplasias Colorrectales , Resección Endoscópica de la Mucosa , Humanos , Resección Endoscópica de la Mucosa/efectos adversos , Hemorragia Posoperatoria/inducido químicamente , Hemorragia Posoperatoria/epidemiología , Estudios Retrospectivos , Factores de Riesgo , Neoplasias Colorrectales/complicaciones , Anticoagulantes/efectos adversos
5.
BMC Gastroenterol ; 23(1): 347, 2023 Oct 06.
Artículo en Inglés | MEDLINE | ID: mdl-37803276

RESUMEN

BACKGROUND: Surveillance colonoscopy decreases colorectal cancer mortality; however, lesions are occasionally missed. Although an appropriate surveillance interval is indicated, variations may occur in the methods used, such as scope manipulation or observation. Therefore, individual endoscopists may miss certain areas. This study aimed to verify the effectiveness of performing repeat colonoscopies with a different endoscopist from the initial procedure. METHODS: We retrospectively reviewed a database of 8093 consecutive colonoscopies performed in the Omori Red Cross Hospital from January 1st 2018 to June 30th 2021. Data from repeat total colonoscopies performed within three months were collected to assess missed lesions. The patients were divided into two groups according to whether the two examinations were performed by different endoscopists (group D) or the same endoscopist (group S). The primary outcome in both groups was the missed lesion detection rate (MLDR). RESULTS: Overall, 205 eligible patients were analyzed. In total, 102 and 103 patients were enrolled in groups D and S, respectively. The MLDR was significantly higher in group D (61.8% vs. 31.1%, P < 0.0001). Multivariate logistic regression analysis for the detection of missed lesions identified performance by the different endoscopists (odds ratio, 3.38; 95% CI, 1.81-6.30), and sufficient withdrawal time (> 6 min) (odds ratio, 3.10; 95% CI, 1.12-8.61) as significant variables. CONCLUSIONS: Overall, our study showed a significant improvement in the detection of missed lesions when performed by different endoscopists. When performing repeat colonoscopy, it is desirable that a different endoscopist perform the second colonoscopy. TRIAL REGISTRATION: This study was approved by the Institutional Review Board of the Omori Red Cross Hospital on November 28, 2022 (approval number:22-43).


Asunto(s)
Adenoma , Pólipos del Colon , Neoplasias Colorrectales , Humanos , Estudios Retrospectivos , Pólipos del Colon/patología , Colonoscopía/métodos , Oportunidad Relativa , Adenoma/diagnóstico , Neoplasias Colorrectales/diagnóstico , Neoplasias Colorrectales/patología
6.
Scand J Gastroenterol ; 57(2): 253-259, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34727817

RESUMEN

BACKGROUND: Although the use of cold snare polypectomy (CSP) has spread rapidly, no prospective studies evaluating the safety of CSP for pedunculated (Ip) polyps have been carried out. AIM: We performed this study to provide an accurate evaluation of the safety of CSP for Ip polyps. METHODS: This is a prospective study (UMIN000035687). From January 2019 to February 2021, the safety of CSP for use on Ip polyps <10 mm with thin stalks was evaluated at our hospital. The primary outcome measure was the incidence of bleeding (delayed post-polypectomy bleeding (DPPB) and immediate bleeding). RESULTS: During the study period, 89 consecutive patients (including 92 colonoscopies and 114 polyps) were prospectively enrolled. The en-bloc resection rate was 100%. The rate of DPPB after CSP was 0%, however, DPPB after conversion to HSP occurred in 1 case (33.3% (1/3)). The rate of immediate bleeding during CSP was 28.9% (33/114). Polyps with diameters ≥6 mm (OR (95% CI): 2.77 (1.041-7.376); p = .041) were extracted as independent risk factors for immediate bleeding during CSP for Ip polyps. In all, 104 (91.2%) polyps were low-grade adenomas, and the percentage of cases with negative pathological margins was 96.5% (110/114). CONCLUSIONS: CSP for Ip polyps was safe and had good outcomes. We believe that Ip polyps could be included as an indication for CSP, and that CSP may become the next step in the 'cold revolution.' To confirm our results and verify CSP's inclusion in future guidelines, prospective, randomized studies are necessary.


Asunto(s)
Adenoma , Pólipos del Colon , Pólipos del Colon/patología , Pólipos del Colon/cirugía , Colonoscopía/métodos , Estudios de Factibilidad , Humanos , Estudios Prospectivos
7.
Gastric Cancer ; 25(6): 1031-1038, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35879522

RESUMEN

BACKGROUND: As the indications for endoscopic submucosal dissection (ESD) for early gastric cancer have been revised, diagnostic ESD has increased. However, despite the technical difficulty of ESD for large lesions, the degree to which curative resection can be achieved has not been clarified. This study investigated the feasibility and safety of ESD for gastric lesions larger than 5 cm. METHODS: This retrospective multicenter study included 3474 gastric lesions treated by ESD from April 2012 to December 2021. We compared clinicopathological characteristics and treatment outcomes between lesions ≥ 5 cm and lesions < 5 cm. RESULTS: There were 128 lesions in the ≥ 5 cm group and 3282 lesions in the < 5 cm group. In the ≥ 5 cm group, upper location and fibrosis during ESD were more common, with a lower rate of 0-IIc type. Both en bloc resection rate and R0 resection rate were comparable, but there was a difference in curative resection rate (65.6% in the ≥ 5 cm group and 91.5% in the < 5 cm group). The frequency of adverse events (post-ESD bleeding, perforation, or stenosis) was almost similar, but delayed perforation was significantly more common (1.6% in the ≥ 5 cm group vs. 0.1% in the < 5 cm group). CONCLUSIONS: About two-thirds of curative resections were obtained with ESD for early gastric lesions larger than 5 cm, but delayed complications should be noted (Number: UMIN000047725).


Asunto(s)
Resección Endoscópica de la Mucosa , Neoplasias Gástricas , Humanos , Resección Endoscópica de la Mucosa/efectos adversos , Neoplasias Gástricas/patología , Mucosa Gástrica/cirugía , Mucosa Gástrica/patología , Disección , Estudios de Factibilidad , Estudios Retrospectivos , Resultado del Tratamiento
8.
Surg Endosc ; 36(7): 5348-5355, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-34997339

RESUMEN

BACKGROUND: Although endoscopic submucosal dissection (ESD) enables en bloc removal of colorectal neoplasms, its effectiveness for larger lesions (≥ 10 cm in diameter) is undetermined. We aimed to investigate the feasibility and safety of ESD for colorectal lesions ≥ 10 cm wide. METHODS: This retrospective study included 3591 consecutive colorectal lesions managed with ESD from June 2012 through December 2020. Clinicopathological characteristics and treatment outcomes were compared between lesions ≥ 10 cm wide and lesions 5-10 cm wide. RESULTS: There were 50 patients in the ≥ 10 cm group and 270 patients in the 5-10 cm group. Among patients in the ≥ 10 cm group, lesions were most often in the rectum (50.0%), and the laterally spreading tumor-granular nodular mixed type (LST-G-M) was most prevalent (41/50, 82%). Although patients in the ≥ 10 cm group a longer mean ESD procedure time (186.0 vs. 94.4 min, p < 0.001), the dissection speed was significantly higher in this group (0.50 vs. 0.41 cm2/min, p = 0.003). The en bloc and curative resection rates were comparable between the ≥ 10 cm and 5-10 cm groups (100% vs. 99.6% and 86.0% vs. 88.5%, respectively). Although the stenosis rate was higher in the ≥ 10 cm group (4% vs. 0%), the delayed bleeding and perforation rates were similar between the two groups. CONCLUSIONS: ESD for colorectal lesions ≥ 10 cm wide is feasible and curative, even though it is associated with higher technical difficulty and longer procedure times compared with ESD for smaller lesions (Number: UMIN 000044313).


Asunto(s)
Neoplasias Colorrectales , Resección Endoscópica de la Mucosa , Colonoscopía/métodos , Neoplasias Colorrectales/patología , Neoplasias Colorrectales/cirugía , Disección/métodos , Resección Endoscópica de la Mucosa/efectos adversos , Resección Endoscópica de la Mucosa/métodos , Estudios de Factibilidad , Humanos , Mucosa Intestinal/patología , Mucosa Intestinal/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
9.
Gastrointest Endosc ; 93(3): 671-678, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32950596

RESUMEN

BACKGROUND AND AIMS: The number of colorectal endoscopic submucosal dissections (ESDs) for early colorectal cancer is expected to increase in the future; therefore, cost reduction is a clinically important issue. The SOUTEN snare (Kaneka Medics, Tokyo, Japan) is a novel multifunctional snare developed for hybrid ESD at a low price. If ESD can be performed safely using the SOUTEN snare, the same therapeutic effect can be obtained as with conventional ESD at a lower cost. The aim of this prospective, pilot, clinical feasibility study was to evaluate the safety and efficacy of ESD using the SOUTEN snare (SOUTEN-ESD). METHODS: From October 2018 to January 2019, 119 consecutive patients (121 ESD procedures, 137 colorectal neoplasms) were prospectively enrolled and treated by SOUTEN-ESD at NTT Medical Center Tokyo and Omori Red Cross Hospital. The outcomes of SOUTEN-ESD were evaluated. RESULTS: Among 137 neoplasms, SOUTEN-ESD was completed in all cases. No cases required conversion to hybrid ESD or to a dedicated ESD device. The mean procedure time was 26.1 ± 14.3 minutes. Both the en-bloc resection rate and R0 resection rate were 100%. The rate of perforation was 0%, the rate of delayed bleeding was 2.2%, and the rate of post-ESD coagulation syndrome was 2.9%. CONCLUSIONS: SOUTEN-ESD was safe and had good outcomes. Although further studies are required to examine indications for SOUTEN-ESD and confirm the results of this study, effective ESD with this novel knife is feasible. The SOUTEN snare is a realistic option for colorectal ESD. (Clinical trial registration number: UMIN 000034299.).


Asunto(s)
Neoplasias Colorrectales , Resección Endoscópica de la Mucosa , Neoplasias Colorrectales/cirugía , Estudios de Factibilidad , Humanos , Japón , Estudios Prospectivos , Resultado del Tratamiento
10.
Endoscopy ; 53(1): 77-80, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32645728

RESUMEN

BACKGROUND: Endoscopic resection of large pedunculated colorectal polyps is technically difficult, especially when the polyp is large and has such a thick stalk that it is either too difficult or impossible to resect prophylactically by a conventional snare. Here, we evaluated the feasibility of ESD for large pedunculated polyps with wide stalks. METHODS: 29 patients with large pedunculated polyps that were not resectable by polypectomy or endoscopic mucosal resection were enrolled in the study. RESULTS: En bloc resection was achieved in 28/29 polyps. One suspended case was due to severe fibrosis with muscle retraction signs. The mean diameter of the 29 polyp heads was 39.7 (standard deviation 6.9) mm. Submucosal fibrosis was present in 16 polyps (9 mild; 7 severe). The stalks of severely fibrotic polyps were significantly thicker than those of polyps with no or mild fibrosis. The curative resection rate was 85.7 % without severe complications. CONCLUSIONS: ESD is feasible for the removal of large pedunculated polyps with wide stalks when conventional snare resection is difficult or impossible.


Asunto(s)
Pólipos del Colon , Resección Endoscópica de la Mucosa , Pólipos del Colon/cirugía , Colonoscopía , Endoscopía , Humanos , Pólipos Intestinales/cirugía , Estudios Retrospectivos
11.
BMC Gastroenterol ; 21(1): 74, 2021 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-33593282

RESUMEN

BACKGROUND: When performing colorectal endoscopic submucosal dissection (ESD) in obese patients, technically difficult cases are sometimes experienced because of difficulty with the insertion of the colonoscope, poor scope maneuverability, or an abundance of fat tissue in the submucosal layer. Since the association between obesity and colorectal ESD has not been investigated, we evaluated the clinical impact of obesity in patients who underwent colorectal ESD. METHODS: We retrospectively reviewed 535 patients who underwent colorectal ESD between April 2012 and February 2019. Patients were divided into three groups based on their body mass index (BMI): a control group (BMI < 25 kg/m2), an overweight group (25 kg/m2 ≤ BMI < 30 kg/m2), and an obese group (BMI ≥ 30 kg/m2), and the short-term clinical outcomes were analyzed to assess the safety and difficulty of colorectal ESD. RESULTS: No significant difference in the procedure times, en bloc resection rates, pathological diagnoses, or complications were seen among the groups. While the amount of sedative per body weight was significantly lower in the group with a higher BMI (flunitrazepam: 1.75 × 10-2 [1.27 × 10-2-2.34 × 10-2] mg/kg vs. 1.48 × 10-2 [1.08 × 10-2-2.03 × 10-2] mg/kg vs. 1.16 × 10-2 [0.98 × 10-2-1.54 × 10-2] mg/kg, P < 0.001; pethidine: 0.63 [0.55-0.72] mg/kg vs. 0.50 [0.46-0.56] mg/kg vs. 0.39 [0.32-0.45] mg/kg, P < 0.001), a reduction in percutaneous arterial oxygen saturation occurred significantly more frequently in the group with a higher BMI (123 [30.2%] vs. 43 [43.9%] vs. 10 [55.6%], P = 0.005). When the procedures were performed by trainees, the number of cases that required a procedure time of longer than 90 min was significantly larger in the group with a higher BMI (27 [10.8%] vs. 14 [21.9%] vs. 3 [25.0%], P = 0.033). CONCLUSIONS: This study showed that colorectal ESD could be performed safely and effectively in obese patients. However, ESD in obese patients requires attention, particularly to changes in respiratory conditions.


Asunto(s)
Neoplasias Colorrectales , Resección Endoscópica de la Mucosa , Colonoscopía , Neoplasias Colorrectales/complicaciones , Neoplasias Colorrectales/cirugía , Resección Endoscópica de la Mucosa/efectos adversos , Humanos , Obesidad/complicaciones , Estudios Retrospectivos , Resultado del Tratamiento
12.
Gastric Cancer ; 24(5): 1160-1166, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33860382

RESUMEN

A 93-year-old female underwent curative endoscopic submucosal dissection (ESD) for intramucosal gastric cancer (70 mm in diameter) in the antrum. The lesion showed an irregularly villous structure covered with mucus. En bloc resection was performed. The large resected specimen induced a longitudinal laceration on the right wall of the esophagogastric junction (EGJ) during retrieval. Unavoidably, we segmented the specimen in the stomach to facilitate retrieval. Histopathological evaluation of the specimen revealed well-to-moderately differentiated tubular and papillary adenocarcinoma. A new elevated lesion (15 mm in diameter) was found at the gastric side of the EGJ laceration scar 6 months after the first ESD, necessitating a second resection with ESD. Endoscopic, histopathological, and immunohistochemical features of the new lesion resembled those of the antral lesion. We assessed the new lesion as a recurrence of cancer caused by implantation of tumor cells in the mucosal laceration after ESD.We experienced recurrence caused by implantation of tumor cells in a mucosal laceration after curative gastric ESD. Endoscopist should be aware of the risk of implantation after gastric ESD.


Asunto(s)
Adenocarcinoma Papilar , Resección Endoscópica de la Mucosa , Neoplasias Gástricas , Anciano de 80 o más Años , Resección Endoscópica de la Mucosa/efectos adversos , Endoscopía , Unión Esofagogástrica , Femenino , Mucosa Gástrica/cirugía , Humanos , Estudios Retrospectivos , Neoplasias Gástricas/cirugía , Resultado del Tratamiento
13.
Dig Dis Sci ; 66(7): 2353-2361, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-32623550

RESUMEN

BACKGROUND: Although the use of cold snare polypectomy (CSP) has spread rapidly, its safety for pedunculated (Ip) polyps remains controversial. In particular, the outcomes of hot snare polypectomy (HSP) and CSP for Ip polyps have not been previously compared. AIMS: This study evaluated whether the rate of delayed postpolypectomy bleeding (DPPB) after CSP for Ip polyps was higher than that after HSP for Ip polyps and compared other outcomes (the rates of immediate bleeding and pathological margins) between the HSP and CSP procedures. METHODS: A total of 5905 colorectal polyps in 4920 patients were resected at Omori Red Cross Hospital between October 2012 and June 2019. The polyps were divided into two groups: the HSP group (86 polyps, 64 patients) and the CSP group (102 polyps, 87 patients). The primary outcome measure was the incidence of DPPB. The secondary outcome measures were the incidences of immediate bleeding during the procedure and pathological margins of the resected specimen. RESULTS: The rate of immediate bleeding during CSP was significantly higher than that for the HSP group [38.2% (39/102) versus 3.5% (3/86); p < 0.001]. However, the rate of DPPB was significantly higher in the HSP group than in the CSP group [4.7% (4/86) versus 0% (0/102); p < 0.001]. The rate of DPPB after CSP was 0%. CONCLUSIONS: This is the first study to compare the outcomes of HSP and CSP for Ip polyps. CSP is safer than HSP for Ip polyps measuring < 10 mm in diameter.


Asunto(s)
Pólipos del Colon/patología , Pólipos del Colon/cirugía , Procedimientos Quirúrgicos del Sistema Digestivo/efectos adversos , Procedimientos Quirúrgicos del Sistema Digestivo/instrumentación , Equipo Quirúrgico , Procedimientos Quirúrgicos del Sistema Digestivo/métodos , Electrocoagulación , Humanos , Hemorragia Posoperatoria/prevención & control , Factores de Riesgo , Factores de Tiempo
14.
Int J Colorectal Dis ; 35(5): 859-867, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32112197

RESUMEN

BACKGROUND: Although cold snare polypectomy (CSP) has spread rapidly, it still remains controversial whether CSP is safe for pedunculated (Ip) polyps. PURPOSE: The aim of this study was to evaluate whether CSP for Ip polyps measuring less than 10 mm in diameter might be associated with an increased rate of delayed post-polypectomy bleeding (DPPB). METHODS: A total of 1641 colorectal polyps in 634 patients were resected at Omori Red Cross Hospital between April 2018 and December 2018. The polyps were divided into two groups depending on the morphology: the Ip group (90 polyps), and the non-Ip group (1551 polyps). RESULTS: Among the 1641 polyps, there was no case of DPPB, including in the Ip group. Immediate bleeding occurred in a total of 101 (6.2%) cases. Polyp location in the rectum (OR (95% CI), 3.61 (1.843-7.092); p < 0.001), polyp diameter ≥ 6 mm (OR (95% CI), 2.65 (1.702-4.132); p < 0.001), Ip morphology (OR (95% CI), 15.66 (9.262-26.49); p < 0.001), and treatment with antithrombotic agents (OR (95% CI), 2.18 (1.358-3.501); p = 0.0012) were identified as significant risk factors for immediate bleeding. CONCLUSIONS: This is the first study conducted to examine the safety of CSP for Ip polyps measuring less than 10 mm in diameter. CSP can be performed with a high level of safety even for Ip polyps. Based on our findings, we believe that Ip polyps could be included as an indication for CSP. However, prospective, randomized studies are necessary to confirm our results.


Asunto(s)
Pólipos del Colon/patología , Pólipos del Colon/cirugía , Procedimientos Quirúrgicos del Sistema Digestivo/efectos adversos , Anciano , Femenino , Hemorragia/etiología , Humanos , Masculino , Análisis Multivariante , Factores de Riesgo , Resultado del Tratamiento
15.
Dig Dis Sci ; 65(1): 232-242, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31312991

RESUMEN

BACKGROUND AND STUDY AIMS: Varying degrees of fibrosis in colorectal endoscopic submucosal dissection (ESD) make the procedure difficult. Consensus on the predictive factors of fibrosis degree (mild or severe) has not been established. We conducted a study to identify the predictive factors and to examine the feasibility of ESD for fibrotic lesions. PATIENTS AND METHODS: We included 518 patients who had undergone ESD for 558 lesions from April 2012-September 2018. Patients were classified into fibrosis or no-fibrosis groups, and logistic regression analysis was performed to identify predictive factors of fibrosis. Subgroup analyses were performed for fibrosis degree. RESULTS: The total incidence of fibrosis was 21.1% (mild: 14.1%; severe: 7.1%). Although the curative resection rate (free margin: invasion depth less than 1000 µm: no lymphatic invasion, vascular involvement) was lower in the fibrosis group compared with the control (80.7% vs. 97.6%), neither the en bloc resection rate (99.1% vs. 100%) nor incidence of perforation (0.9% vs. 0.2%) differed between the two groups. Multivariate analysis revealed that a cecal location, preoperative biopsy, straddling fold, laterally spreading tumor-non-granular-pseudo-depressed (LST-NG-PD) type were predictive of mild fibrosis. The presence of a straddling fold and a protruded lesion were independent predictive factors of severe fibrosis. CONCLUSIONS: We identified the predictive factors of mild and severe fibrosis. It is preferable that a more experienced physician performs ESD for the lesions with F2 fibrosis.


Asunto(s)
Colonoscopía , Neoplasias Colorrectales/cirugía , Resección Endoscópica de la Mucosa , Anciano , Anciano de 80 o más Años , Colonoscopía/efectos adversos , Neoplasias Colorrectales/patología , Resección Endoscópica de la Mucosa/efectos adversos , Estudios de Factibilidad , Femenino , Fibrosis , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
16.
Dig Endosc ; 32(4): 621-627, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-31965622

RESUMEN

Lugol chromoendoscopy is useful for the detection of early esophageal squamous cell cancer (ESCC). Multiple lugol-voiding lesions (LVLs) on lugol chromoendoscopy are associated with a very high risk of multiple cancers arising in the esophagus. Due to the widespread use of narrow band image technology in many institutions, esophageal cancer without LVLs in the background esophagus is sometimes detected. This retrospective study aims to clarify the clinical characteristic of esophageal cancer without LVLs in the background esophagus. A total of 191 consecutive patients with 204 ESCCs had undergone endoscopic submucosal dissection (ESD) from 2011 and 2014. Amongst these lesions, the number of LVLs in the background esophagus per endoscopic view was counted excluding main lesion, and the grading was divided into no LVLs ESCC (nL-ESCC) group and LVLs ESCC (L-ESCC) group. This study evaluated the clinical characteristics and the cumulative incidence of metachronous ESCC after ESD in both groups. Thirty-six patients with 36 lesions and 155 patients with 168 lesions were separated into the nL-ESCC group and L-ESCC group, respectively. On multivariate analysis, the nL-ESCC group was found to be more common in females, who were non-drinkers, or with erosive esophagitis. During follow-up periods, the cumulative incidence of metachronous ESCC at 3-years was 14.4% and 0.00% in the L-ESCC and nL-ESCC groups, respectively (P < 0.01). Our study showed that esophageal cancer without LVLs in the background esophagus was mostly occurred in females, who were non-drinkers, or with erosive esophagitis, which are uncommon features of ESCC.


Asunto(s)
Resección Endoscópica de la Mucosa , Neoplasias Esofágicas/diagnóstico , Carcinoma de Células Escamosas de Esófago/diagnóstico , Esofagoscopía , Neoplasias Primarias Secundarias/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Colorantes , Neoplasias Esofágicas/cirugía , Carcinoma de Células Escamosas de Esófago/cirugía , Femenino , Humanos , Yoduros , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Neoplasias Primarias Secundarias/cirugía , Estudios Retrospectivos
17.
Int J Colorectal Dis ; 34(9): 1563-1569, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31312890

RESUMEN

BACKGROUND: Incomplete polyp resection (IPR) is recognized as a risk factor for interval colorectal cancer (ICC), and is, therefore, an important issue in polypectomy. Cold snare polypectomy (CSP) is a procedure that does not involve electrocautery and has no burn effect. Therefore, there is the possibility that the risk of ICC associated with IPR is higher in cases undergoing CSP than in those undergoing hot polypectomy. However, little is known about the risk factors for IPR after CSP. PURPOSE: Precise identification of the risk factors can lead to prevention of IPR after CSP. Therefore, we performed this observational study for accurate identification of the risk factors for IPR after CSP. METHODS: Medical records of a total of 501 patients with 1177 colorectal polyps that were resected at Omori Red Cross Hospital between October 2017 and March 2018 were retrospectively reviewed. The lateral and deep margins of the resected polyps were evaluated to check for the resection completeness. RESULTS: Among the 1177 polyp resections, 1163 were included in the final analysis. IPR was detected in 206 (17.7%) cases. Performance of the resection by a trainee (OR (95% CI) 1.87 (1.328-2.632); P < 0.001) was identified as an independent risk factor for IPR in patients undergoing CSP. CONCLUSIONS: Performance of the polypectomy by a trainee was identified as a significant risk factor for IPR in patients undergoing CSP. Prospective, randomized studies are necessary in the future to develop effective methods for the prevention/control of IPR after CSP.


Asunto(s)
Pólipos del Colon/cirugía , Anciano , Femenino , Humanos , Masculino , Análisis Multivariante , Factores de Riesgo
18.
Dig Dis Sci ; 64(3): 880-887, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30284133

RESUMEN

BACKGROUND: Endoscopic submucosal dissection (ESD) is an effective treatment for early-colorectal cancer. Although delayed bleeding is a serious potential complication, there is no consensus on the optimal protocol to determine which cases require emergency colonoscopy. AIMS: This study aimed to assess the risk factors for delayed bleeding after ESD and evaluate the "watch and wait" strategy for delayed bleeding. The "watch and wait" strategy was used for delayed bleeding, unless the shock index was ≥ 1 and/or a moderate amount of hematochezia occurred more than five occurrences. METHODS: This study included 404 patients who had undergone endoscopic resection for 439 lesions between April 2012 and February 2018. Patients were classified into the bleeding group or the no-bleeding group to investigate the risk factors for delayed bleeding, and to assess the necessity of emergency colonoscopy. RESULTS: Twenty-seven patients into the bleeding group and 412 into the no-bleeding group were classified. However, no case required emergency colonoscopy for hemostasis under "watch and wait strategy." Multivariate analysis revealed the risk factors for bleeding were rectal lesion (OR 5.547, 95% CI 1.456-21.130; P = 0.012) and lesion size ≥ 40 mm (OR 3.967, 95% CI 1.003-15.696; P = 0.05). CONCLUSIONS: Risk factors for delayed bleeding are rectal lesions and lesion size ≥ 40 mm. This watch and wait strategy resulted in no requirements for emergency colonoscopy or blood transfusion, and no serious conditions caused by delayed bleeding.


Asunto(s)
Colonoscopía/métodos , Neoplasias Colorrectales/cirugía , Resección Endoscópica de la Mucosa/efectos adversos , Hemorragia Gastrointestinal/cirugía , Hemostasis Endoscópica/métodos , Hemorragia Posoperatoria/cirugía , Anciano , Anciano de 80 o más Años , Toma de Decisiones Clínicas , Colonoscopía/efectos adversos , Neoplasias Colorrectales/patología , Urgencias Médicas , Femenino , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiología , Hemostasis Endoscópica/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Selección de Paciente , Hemorragia Posoperatoria/diagnóstico , Hemorragia Posoperatoria/etiología , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
19.
Dig Dis Sci ; 64(11): 3247-3255, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-30684074

RESUMEN

BACKGROUND: With the aging of the population and rising incidence of thromboembolic events, the clinical use of antithrombotic agents is also increasing. There are few reports yet on the management of antithrombotic agent use in patients undergoing cold snare polypectomy (CSP). AIMS: The aim of this study was to evaluate whether continued administration of antithrombotic agents in patients undergoing CSP would be associated with an increased rate of delayed post-polypectomy bleeding (DPPB). METHODS: A total of 1177 colorectal polyps in 501 patients were resected at Omori Red Cross Hospital between October 2017 and March 2018. The polyps were divided into two groups depending on whether the patients received antithrombotic agent treatment or not: the antithrombotic group (911 polyps) and the no-antithrombotic group (266 polyps). RESULTS: Among the 1177 polyp resections, there was no case of DPPB, including in the antithrombotic group. Immediate bleeding occurred in a total of 63 (5.4%) cases. Polyp location in the rectum (OR (95% CI) 2.64 (1.223-5.679); p = 0.013), polyp size ≥ 6 mm (OR (95% CI) 4.64 (2.719-7.933); p < 0.001), polypoid growth pattern (OR (95% CI) 2.78 (1.607-4.793); p < 0.001), and antithrombotic agent use (OR (95% CI) 2.98 (1.715-5.183); p < 0.001) were identified as significant risk factors of immediate bleeding. CONCLUSIONS: Continued use of antithrombotic agents does not increase the risk of DPPB, even in those receiving multiple antithrombotic agents. Thus, it is safe to perform CSP even in multiple agent users. Prospective, randomized studies are necessary to confirm our results.


Asunto(s)
Colectomía/métodos , Pólipos del Colon/tratamiento farmacológico , Pólipos del Colon/cirugía , Fibrinolíticos/uso terapéutico , Recto/patología , Recto/cirugía , Anciano , Pólipos del Colon/diagnóstico , Femenino , Fibrinolíticos/farmacología , Humanos , Masculino , Persona de Mediana Edad , Recto/efectos de los fármacos , Estudios Retrospectivos , Resultado del Tratamiento
20.
Biol Pharm Bull ; 42(2): 295-298, 2019 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-30504641

RESUMEN

Surface free energy (SFE) is an important factor for evaluation of wettability or adhesion. Thus, the SFE of a Yucatan micropig (YMP) skin and a hairless mouse (HM) skin, which are commonly used in skin permeation studies instead of human skin, were compared with the human skin. Contact angles of water and 1-bromo naphthalene to skin were measured and the SFE was calculated using the Owens-Wendt equation. The SFE of the human abdominal skin was 40 mN/m and its polar component σsp was as low as 2 mN/m, which was similar to that of the low sebum skin reported previously. In the case of the YMP skin, σsp was high on the surface but similar to that obtained after the skin was tape-stripped twice. The HM skin showed similar SFE as that of the human skin. When the surfactant was applied on the skin, wiped, and dried, the remaining surfactant increased the SFE in σsp; however, the original SFE was obtained after rinsing with water. The YMP skin and HM skin is similar to the human abdominal skin with a low sebum level. Thus, they are also good skin models for studying wettability or adhesion of a substance.


Asunto(s)
Fenómenos Fisiológicos de la Piel , Piel/metabolismo , Adulto , Factores de Edad , Animales , Femenino , Humanos , Ratones , Ratones Pelados , Persona de Mediana Edad , Piel/efectos de los fármacos , Tensión Superficial , Tensoactivos/farmacología , Porcinos , Porcinos Enanos , Humectabilidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA