Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Graefes Arch Clin Exp Ophthalmol ; 262(5): 1607-1618, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38183466

RESUMEN

PURPOSE: Estimating glaucoma suspects' risk for visual field defects helps to avoid under- and over-treatment. In this retrospective, longitudinal cohort study with a very long follow-up, we studied whether pattern electroretinograms (PERG) amplitudes and blue-on-yellow visual evoked potential (BY-VEP) latencies can predict visual field defects. METHODS: Participants of the Erlangen Glaucoma Study were examined with PERG and BY-VEP between 9/1991 and 8/2001. Stimuli were created using an optical bench with Maxwellian view and consisted of vertical gratings (0,88 cpd) in a 32° field for both PERG and BY-VEP. Patients were treated according to clinical standards and performed standard automated perimetry (SAP) annually. Retrospectively, patients with normal SAP at baseline were selected. Primary endpoint was conversion to perimetric glaucoma. Predictive value was modeled using Kaplan-Meier analyses and a multivariate cox proportional hazards model with the continuous variables PERG amplitude, BY-VEP peak time and SAP square-root of loss variance (sLV) after stratification for Jonas classification of the optic discs. RESULTS: Of 412 patients (288: Jonas 0, 103: I, and 21: II; baseline age: 20-60 years), 65 converted to perimetric glaucoma during follow-up (0.5-23.3 years; median 5.5 years). Optic disc classification was a strong risk factor for conversion (log rank p < 0.0001), and patients with more advanced changes progressed earlier. In the multivariate analysis (log rank p = 0.005), only PERG amplitude remained an independent risk factor after stratification for optic disc morphology (p = 0.021), with a ~ 30% higher risk per µV amplitude decrease. CONCLUSIONS: PERG helps to estimate glaucoma suspects' risk for visual field defects.


Asunto(s)
Glaucoma , Hipertensión Ocular , Humanos , Adulto Joven , Adulto , Persona de Mediana Edad , Pruebas del Campo Visual , Potenciales Evocados Visuales , Estudios Retrospectivos , Campos Visuales , Estudios de Seguimiento , Estudios Longitudinales , Presión Intraocular , Hipertensión Ocular/tratamiento farmacológico , Glaucoma/diagnóstico , Electrorretinografía , Trastornos de la Visión/diagnóstico
2.
Graefes Arch Clin Exp Ophthalmol ; 260(4): 1171-1181, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34821990

RESUMEN

BACKGROUND AND AIM: In the past, increased latencies of the blue-on-yellow pattern visually evoked potentials (BY-VEP), which predominantly originate in the koniocellular pathway, have proven to be a sensitive biomarker for early glaucoma. However, a complex experimental setup based on an optical bench was necessary to obtain these measurements because computer screens lack sufficient temporal, spatial, spectral, and luminance resolution. Here, we evaluated the diagnostic value of a novel setup based on a commercially available video projector. METHODS: BY-VEPs were recorded in 126 participants (42 healthy control participants, 12 patients with ocular hypertension, 17 with "preperimetric" glaucoma, and 55 with perimetric glaucoma). Stimuli were created with a video projector (DLP technology) by rear projection of a blue checkerboard pattern (460 nm) for 200 ms (onset) superimposed on a bright yellow background (574 nm), followed by an offset interval where only the background was active. Thus, predominantly S-cones were stimulated while L- and M-cone responses were suppressed by light adaptation. Times of stimulus onset to VEP onset-trough (N-peak time) and offset-peak (P-peak time) were analyzed after age-correction based on linear regression in the normal participants. RESULTS: The resulting BY-VEPs were quite similar to those obtained in the past with the optical bench: pattern-onset generated a negative deflection of the VEP, whereas the offset-response was dominated by a positive component. N-peak times were significantly increased in glaucoma patients (preperimetric 136.1 ± 10 ms, p < 0.05; perimetric 153.1 ± 17.8 ms, p < 0.001) compared with normal participants (123.6 ± 7.7 ms). Furthermore, they were significantly correlated with disease severity as determined by visual field losses retinal nerve fiber thinning (Spearman R = -0.7, p < 0.001). CONCLUSIONS: Video projectors can be used to create optical stimuli with high temporal and spatial resolution, thus potentially enabling sophisticated electrophysiological measurements in clinical practice. BY-VEPs based on such a projector had a high diagnostic value for detection of early glaucoma. Registration of study Registration site: www. CLINICALTRIALS: gov Trial registration number: NCT00494923.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Hipertensión Ocular , Potenciales Evocados Visuales , Glaucoma/diagnóstico , Glaucoma de Ángulo Abierto/diagnóstico , Humanos , Pruebas del Campo Visual
3.
Int J Mol Sci ; 23(13)2022 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-35806214

RESUMEN

Long COVID (LC) describes the clinical phenotype of symptoms after infection with the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Diagnostic and therapeutic options are limited, as the pathomechanism of LC is elusive. As the number of acute SARS-CoV-2 infections was and is large, LC will be a challenge for the healthcare system. Previous studies revealed an impaired blood flow, the formation of microclots, and autoimmune mechanisms as potential factors in this complex interplay. Since functionally active autoantibodies against G-protein-coupled receptors (GPCR-AAbs) were observed in patients after SARS-CoV-2 infection, this study aimed to correlate the appearance of GPCR-AAbs with capillary microcirculation. The seropositivity of GPCR-AAbs was measured by an established cardiomyocyte bioassay in 42 patients with LC and 6 controls. Retinal microcirculation was measured by OCT-angiography and quantified as macula and peripapillary vessel density (VD) by the Erlangen-Angio Tool. A statistical analysis yielded impaired VD in patients with LC compared to the controls, which was accentuated in female persons. A significant decrease in macula and peripapillary VD for AAbs targeting adrenergic ß2-receptor, MAS-receptor angiotensin-II-type-1 receptor, and adrenergic α1-receptor were observed. The present study might suggest that a seropositivity of GPCR-AAbs can be linked to an impaired retinal capillary microcirculation, potentially mirroring the systemic microcirculation with consecutive clinical symptoms.


Asunto(s)
COVID-19 , Adrenérgicos , Autoanticuerpos , COVID-19/complicaciones , Femenino , Humanos , Microcirculación , Receptores Acoplados a Proteínas G , Vasos Retinianos , SARS-CoV-2 , Tomografía de Coherencia Óptica , Síndrome Post Agudo de COVID-19
4.
Int J Mol Sci ; 23(22)2022 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-36430175

RESUMEN

Post-COVID-19 syndrome (PCS) is characterized by persisting sequelae after infection with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). PCS can affect patients with all COVID-19 disease severities. As previous studies have revealed impaired blood flow as a provoking factor triggering PCS, it was the aim of the present study to investigate the potential association between self-reported chronic fatigue and retinal microcirculation in patients with PCS, potentially indicating an objective biomarker. A prospective study was performed, including 201 subjects: 173 patients with PCS and 28 controls. Retinal microcirculation was visualized by OCT angiography (OCT-A) and quantified using the Erlangen-Angio-Tool as macula and peripapillary vessel density (VD). Chronic fatigue (CF) was assessed according to the variables of Bell's score, age and gender. VDs in the superficial vascular plexus (SVP), intermediate capillary plexus (ICP) and deep capillary plexus (DCP) were analyzed, considering the repetitions (12 times). Seropositivity for autoantibodies targeting G protein-coupled receptors (GPCR-AAbs) was determined by an established cardiomyocyte bioassay. Taking account of the repetitions, a mixed model was performed to detect possible differences in the least square means between the different groups included in the analysis. An age effect in relation to VD was observed between patients and controls (p < 0.0001). Gender analysis showed that women with PCS showed lower VD levels in the SVP compared to male patients (p = 0.0015). The PCS patients showed significantly lower VDs in the ICP as compared to the controls (p = 0.0001 (CI: 0.32; 1)). Moreover, considering PCS patients, the mixed model revealed a significant difference between those with chronic fatigue (CF) and those without CF with respect to VDs in the SVP (p = 0.0033 (CI: −4.5; −0.92)). The model included variables of age, gender and Bell's score, representing a subjective marker for CF. Consequently, retinal microcirculation might serve as an objective biomarker in subjectively reported chronic fatigue in patients with PCS.


Asunto(s)
COVID-19 , Síndrome de Fatiga Crónica , Humanos , Masculino , Femenino , Angiografía con Fluoresceína/métodos , COVID-19/complicaciones , Vasos Retinianos , Microcirculación , Tomografía de Coherencia Óptica/métodos , Estudios Prospectivos , SARS-CoV-2 , Fatiga , Biomarcadores , Síndrome Post Agudo de COVID-19
5.
Klin Monbl Augenheilkd ; 238(8): 861-867, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34000747

RESUMEN

PURPOSE: Minimally invasive glaucoma surgery (MIGS), like Xen45 gel stents, is known as effective therapy in lowering intraocular pressure (IOP); however, fibrotic reactions are a common problem in postoperative management. It was the aim of this study to investigate the therapeutic success of Xen45 gel stents as a stand-alone technique (Xen) and combined with cataract surgery (XenPhaco), and with antimetabolites (mitomycin C, MMC) in open-angle glaucoma patients. METHODS: Retrospective analysis was performed of 199 eyes of 177 glaucoma patients of the Department of Ophthalmology, University of Erlangen Nürnberg, and from the Erlangen Glaucoma Registry (NCT00494923; ISSN 2191-5008, CS-2011) who underwent implantation of a Xen45 gel stent. Therapeutic success was defined as IOP reduction of ≥ 20% on the same or less anti-glaucomatous medication after 12 months compared to preoperative and without any additional glaucoma-related surgery (except bleb needling). IOP reduction, reduction in local anti-glaucomatous eye drops, and intra- and postoperative complications were monitored. RESULTS: Stand-alone Xen45 gel stent: therapeutic success was reached in 39% (-MMC) and 55% (+MMC). Failure rate was 61% (-MMC) and 45% (+MMC). XenPhaco: therapeutic success was achieved in 57% (-MMC) and 46% (+MMC). Failure rate was 43% (-MMC) and 54% (+MMC). Data were not different for group and subgroup analyses (p > 0.05). CONCLUSIONS: The use of MMC seemed to increase the therapeutic success rate after stand-alone Xen45 gel stent implantation and combined with cataract surgery, yet statistical significant was not reached.


Asunto(s)
Catarata , Implantes de Drenaje de Glaucoma , Glaucoma de Ángulo Abierto , Glaucoma de Ángulo Abierto/complicaciones , Glaucoma de Ángulo Abierto/tratamiento farmacológico , Humanos , Presión Intraocular , Mitomicina , Estudios Retrospectivos , Stents , Resultado del Tratamiento
6.
Graefes Arch Clin Exp Ophthalmol ; 256(3): 621-625, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29335776

RESUMEN

PURPOSE: Glaucoma, a common disease in the elderly population, is frequently coexistent with cataract. While the combination of filtration surgery and cataract surgery is a challenging topic with limited success, minimal invasive glaucoma surgery (MIGS), such as Xen Gel Stents, seems to provide promising results. The aim of this study was to investigate the complete and qualified therapeutic success of Xen Gel Stent implantation with (XenPhaco) and without cataract surgery. METHODS: One hundred and eleven open-angle glaucoma eyes underwent implantation of Xen45 Gel Stent (AqueSys, Inc.) with or without cataract operation. Complete therapeutic success was defined as target intraocular pressure (IOP) < 18 mmHg at any time point within 6 months of follow-up without local antiglaucomatous therapy or further surgical interventions. Qualified success was defined as target IOP <18 mmHg with additional 1-2 local antiglaucomatous eye drops. Failure included all cases with the necessity of at least three local antiglaucomatous eye drops or additional glaucoma surgery. RESULTS: Combined implantation of Xen Gel Stent with cataract surgery was performed in 30 eyes and stand-alone Xen Gel Stent implantation was performed in 81 eyes. A complete therapeutic success was achieved in 46.9% of single Xen Gel Stent implantation, whereas 53.3% was reached with combined XenPhaco. Qualified success was seen in 2.5% in the eyes of the single Xen Gel Stent implantation group and in 3.3% of the combined surgery group. Therapeutic failure rate was 49.4% in the stand-alone group vs 46.7% in the combined group. Data were not significantly different for group and subgroup analyses. CONCLUSIONS: Complete and qualified therapeutic success is similar for the combination of Xen Gel Stent implantation with and without cataract surgery in open-angle glaucoma patients. MIGS using Xen Gel Stent can be recommended in situations if glaucoma surgery is indicated besides coexisting cataract.


Asunto(s)
Extracción de Catarata/métodos , Cirugía Filtrante/métodos , Glaucoma de Ángulo Abierto/cirugía , Presión Intraocular/fisiología , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Stents , Agudeza Visual , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Glaucoma de Ángulo Abierto/complicaciones , Glaucoma de Ángulo Abierto/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Microscopía con Lámpara de Hendidura , Resultado del Tratamiento , Adulto Joven
7.
Graefes Arch Clin Exp Ophthalmol ; 254(5): 937-46, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26883356

RESUMEN

PURPOSE: To compare perimetric data based on the second-generation frequency doubling technology (FDT) and on flicker defined form (FDF) stimulation in early glaucoma patients. METHODS: Seventy-two experienced glaucoma patients and 50 healthy subjects of the Erlangen Glaucoma Registry participated in the study. The definition of glaucoma was solely based on optic disc appearance. All patients underwent FDF perimetry (HEP), FDT perimetry (Matrix), standard automated perimetry (SAP, Octopus), and peripapillar measurements of the RNFL thickness (Spectralis OCT). Exclusion criteria were: mean defect (MD) in SAP > 6 dB, eye diseases other than glaucoma, or non-reliable FDF or FDT measurements. Statistical analyses included comparison of the standard indices and correlations between methods. Venn-diagrams show the number of patients with abnormal results in HEP, Matrix, SAP, and mean RNFL thickness. RESULTS: Mean defect data from FDT and FDF perimetry were strongly correlated (R = -0.85, P <0.001). In this cohort of early glaucoma patients, the MD values were 6.1 ± 5.0 dB (FDF) and 4.5 ± 4.1 dB (FDT). Sensitivity in this patient group was 65 % for FDF-MD, 60 % for FDT-MD, and 60 % for RNFL-thickness, all at a specificity of 95 %. The correlation analysis between local RNFL thickness and corresponding visual defects revealed significant Spearman correlation coefficients for the arcuate bundles of the visual field (FDF-inferior: R = -0.65, FDF-superior: R = -0.74, FDT-inferior: R = -0.55, FDT-superior: R = -0.72). CONCLUSION: FDF and FDT stimulations can be used to detect patients with early glaucoma. Combined consideration of RNFL thickness and results from one of these perimetric tests can increase the total number of detected patients.


Asunto(s)
Glaucoma de Ángulo Abierto/diagnóstico , Glaucoma de Baja Tensión/diagnóstico , Trastornos de la Visión/diagnóstico , Pruebas del Campo Visual/métodos , Campos Visuales , Adulto , Anciano , Estudios de Cohortes , Diagnóstico Precoz , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fibras Nerviosas/patología , Células Ganglionares de la Retina/patología , Tomografía de Coherencia Óptica
9.
Graefes Arch Clin Exp Ophthalmol ; 253(1): 107-14, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25308782

RESUMEN

PURPOSE: Higher levels of short-term fluctuation of intraocular pressure (IOP) are characteristic of pseudoexfoliation syndrome (PEX). However, it is not known whether they are just a side effect of the higher mean intraocular pressure (IOP) or an independent feature. The purpose of this study was to compare short-term fluctuation of IOP between eyes with PEX and control eyes that were matched as closely as possible for mean IOP. METHODS: In this retrospective case-control study, all patients with confirmed PEX were identified from the database of the Erlangen Glaucoma Registry. From the same database, matched control eyes with similar treatment, age, glaucoma stage, and mean IOP were identified. For each patient, data from multiple extended diurnal IOP profiles were available. RESULTS: Seventy-eight eyes were included in the study (39 with PEX and 39 matched control eyes). Although a very close match was achieved, a small but statistically significant difference in mean IOP was still present, but this did not seem to explain the differences in IOP fluctuation levels. Eyes with PEX had significantly higher short-term IOP fluctuations (SD of IOP and range of IOP). CONCLUSIONS: The higher levels of short-term fluctuation in IOP appear to be an independent feature of PEX and not merely a secondary effect of the higher mean IOP. We suggest that this may have practical implications, even if IOP fluctuation levels should not prove to be an independent risk factor for development/progression of glaucoma, because more frequent measurements are needed in these patients to obtain good estimates of mean IOP and changes in IOP under treatment.


Asunto(s)
Síndrome de Exfoliación/fisiopatología , Glaucoma de Ángulo Abierto/fisiopatología , Presión Intraocular/fisiología , Hipertensión Ocular/fisiopatología , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tonometría Ocular , Pruebas del Campo Visual , Campos Visuales/fisiología
10.
BMC Ophthalmol ; 14: 122, 2014 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-25316067

RESUMEN

BACKGROUND: The diurnal fluctuation of intraocular pressure may be relevant in glaucoma. The aim of this study was to find out whether the timing of diurnal fluctuation is stable over the years. METHODS: Long-term IOP data from the Erlangen Glaucoma Registry, consisting of several annual extended diurnal IOP profiles for each patient, was retrospectively analyzed. Normal subjects, patients with ocular hypertension and with pigment dispersion syndrome were included because these subjects had not been treated with antiglaucomatous medications at the time of data acquisition. A cosine curve was fitted to the IOP data and the stability of individual rhythms over the years was tested using the Rayleigh test. To compare the peak times among groups, means were calculated only from subjects with a significant Rayleigh test. RESULTS: Of the fifty-two eligible subjects, a total of 364 extended diurnal IOP profiles measured in a sitting position had been collected over a period of 114 ± 39 months. The Rayleigh test indicated intraindividual stability of phase timing only in 19 subjects (36%). In subjects with pigment dispersions syndrome, peak IOP occurred on average two hours and seven minutes later during the day compared with subjects without this condition (p = 0.05). CONCLUSIONS: Fitting of cosine curves to the clinical IOP profiles was generally feasible, although careful interpretation is warranted due to lack of measurements in supine position and between midnight and 7 am. The interesting observation of a phase lag in eyes with pigment dispersion syndrome warrants confirmation and exploration in future prospective studies. The analysis of the IOP data showed no stable individual rhythm in the long term in a majority of patients.


Asunto(s)
Ritmo Circadiano/fisiología , Glaucoma de Ángulo Abierto/fisiopatología , Presión Intraocular/fisiología , Hipertensión Ocular/fisiopatología , Adulto , Anciano , Femenino , Voluntarios Sanos , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Postura , Estudios Retrospectivos , Tonometría Ocular
11.
Sci Rep ; 14(1): 10306, 2024 05 05.
Artículo en Inglés | MEDLINE | ID: mdl-38705883

RESUMEN

Multiple ophthalmic diseases lead to decreased capillary perfusion that can be visualized using optical coherence tomography angiography images. To quantify the decrease in perfusion, past studies have often used the vessel density, which is the percentage of vessel pixels in the image. However, this method is often not sensitive enough to detect subtle changes in early pathology. More recent methods are based on quantifying non-perfused or intercapillary areas between the vessels. These methods rely upon the accuracy of vessel segmentation, which is a challenging task and therefore a limiting factor for reliability. Intercapillary areas computed from perfusion-distance measures are less sensitive to errors in the vessel segmentation since the distance to the next vessel is only slightly changing if gaps are present in the segmentation. We present a novel method for distinguishing between glaucoma patients and healthy controls based on features computed from the probability density function of these perfusion-distance areas. The proposed approach is evaluated on different capillary plexuses and outperforms previously proposed methods that use handcrafted features for classification. Moreover the results of the proposed method are in the same range as the ones of convolutional neural networks trained on the raw input images and is therefore a computationally efficient, simple to implement and explainable alternative to deep learning-based approaches.


Asunto(s)
Glaucoma , Vasos Retinianos , Tomografía de Coherencia Óptica , Tomografía de Coherencia Óptica/métodos , Humanos , Glaucoma/diagnóstico por imagen , Glaucoma/diagnóstico , Vasos Retinianos/diagnóstico por imagen , Vasos Retinianos/patología , Femenino , Masculino , Persona de Mediana Edad , Procesamiento de Imagen Asistido por Computador/métodos , Capilares/diagnóstico por imagen , Capilares/patología
12.
J Trace Elem Med Biol ; 78: 127195, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37207415

RESUMEN

PURPOSE: The therapeutic success of minimal invasive glaucoma surgery (MIGS) is challenging due to many factors including fibrotic or occlusive events. Recent clinical data show sudden peaks of intraocular pressure (IOP) in the postoperative care of glaucoma patients after suprachoroidal draining stents. Yet, the reasons for the IOP peaks are speculative. As a link between trace elements and fibrosis had been previously observed in systemic disorders, the present study aimed to investigate the impact of trace elements on the therapeutic success of the suprachoroidal draining stents in patients with open-angle glaucoma (OAG). MATERIAL AND METHODS: An analysis of a prospective single-center study was done: fifty-five eyes of patients with OAG (29 female, 26 male) underwent Cypass Micro-Stent implantation either as a stand-alone procedure or combined with cataract surgery. All patients underwent pre-operatively an ophthalmological examination which included slit lamp biomicroscopy and fundoscopy. IOP was measured by Goldmann applanation tonometry. Functional and morphometric data were assessed by Octopus G1-perimetry, which included measurement of retinal nerve fiber layer thickness (Spectralis OCT). Data of the patients' follow-ups were recorded during 18 months post-operatively. The therapeutic success of CyPass Micro-Stent was classified as 'success' (IOP reduction ≥20% compared to a pre-operative baseline without any medication), 'qualified success' (IOP reduction ≥20 % with same or lower additional eye medication), and 'failure' (IOP reduction ≤20 % or additional surgical treatment necessary). Aqueous humour was extracted once during surgery for analysis of the level of 14 trace elements: Copper (Cu), Cadmium (Cd), Cobalt (Co), Chromium (Cr), Iron (Fe), Lithium (Li), Magnesium (Mg), Manganese (Mn), Phosphorus (P), Lead (Pb), Titanium (Ti), Uranium (U), Vanadium (V), and Zinc (Zn). Analysis of the trace elements was done using an ELEMENT 2, ICP-sf-MS instrument (Thermo-Fisher Scientific, Bremen, Germany). Analysis of levels of trace elements was done across the patients' groups of the three subclasses of therapeutic success. Statistical investigations for substantial differences were conducted using the method of least squares to fit general linear models and mixed models. The last one for the repeated measurements of IOP. RESULTS: Levels of Mg were significantly lower one month postoperatively in the success group (LS-Mean 1.30 mg/L) compared to the qualified success group (LS-Mean 1.22 mg/L; p-value = 0.04). Fe was significantly increased in the failure group (LS-Mean 2.07 µg/L) compared to the qualified success group (LS-Mean 1.64 µg/L; p-value = 0.019) after 3 months of follow-up. Additionally, Fe levels were significantly lower in the success group (LS-Mean 1.47 µg/L) compared to the failure cohort (LS-Mean 2.07 µg/L; p-value = 0.009). After a period of 18 months, significantly higher levels of Mn were observed in the success group (LS-Mean 1.24 µg/L) than in the failure group (LS Mean 0.30 µg/L, p-value = 0.019). CONCLUSION: The present data might suggest that trace elements can influence therapeutic success of suprachoroidal draining devices postoperatively and thus offer first hints for potential novel therapeutic options.


Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma de Ángulo Abierto , Glaucoma , Oligoelementos , Humanos , Masculino , Femenino , Glaucoma de Ángulo Abierto/cirugía , Oligoelementos/uso terapéutico , Estudios Prospectivos , Resultado del Tratamiento , Glaucoma/cirugía
13.
J Glaucoma ; 2023 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-38129946

RESUMEN

PRCIES: Empowering glaucoma patients to access their individual glaucoma related health data by using a digital health application leads to a significant improvement in quality of life and adherence. PURPOSE: Evaluate the effectiveness of improvement of glaucoma associated quality of life and adherence in patients using a digital health application. PATIENTS AND METHODS: A prospective randomized monocentric controlled study of 77 patients with primary open angle glaucoma. Patients were recruited at the University Hospital Erlangen. Patients in the intervention group tracked their intraocular pressure, symptoms and therapy using a digital application. Based on the collected data the SmartTonoTracker® gave patients simple statistics and basic recommendations for further treatment. An increasing score on the GlauQol-36 item questionnaire and the MMAS-8 score, conducted at baseline and follow-up by the intervention group, was considered successful. Statistical analysis was conducted using the unpaired t-test, paired t-test, Man-Whitney-U test, frequency analysis, frequency distribution and Pearson-correlation. RESULTS: Significant difference in the patients´ glaucoma-associated quality of life between the intervention group (rate of improvement: 7.6%, P =0.047), and the control group (rate of improvement: 0.17%, P =0.047) was shown. Also, a significant difference in adherence between the intervention group, showing a 9.8% rate of improvement ( P =0.002), and the control group, showing a 3.8% rate of improvement ( P =0.002), was shown. CONCLUSION: Enabling patients to access individual health related glaucoma data by using a digital health application and supporting them with information on their disease led to an improvement in glaucoma-associated quality of life and adherence.

14.
Doc Ophthalmol ; 124(3): 237-48, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22457046

RESUMEN

The aim of this study is to measure the on- and off-responses and their response asymmetries elicited by sawtooth stimuli in normal subjects and glaucoma patients. Furthermore, the correlation between the ERGs and other functional and structural parameters are investigated. Full-field stimuli were produced using a Ganzfeld bowl with Light Emitting Diodes (LEDs) as light sources. On- and off-response ERGs were recorded from 17 healthy subjects, 12 pre-perimetric and 15 perimetric glaucoma patients using 4-Hz luminance rapid-on and rapid-off sawtooth stimuli (white light; mean luminance 55 cd/m(2)) at 100% contrast. The on- and off-responses were added to study response asymmetries. In addition, flash ERGs were elicited by red stimuli (200 cd/m(2)) on a blue background (10 cd/m(2)). The mean deviations (MD) of the visual field defects were obtained by standard automated perimetry. The retinal nerve fibre layer thickness (RNFLT) was measured with Spectral Domain Optical Coherence Tomography (SOCT). We studied the correlation between ERG response amplitudes, visual field mean deviation (MDs) and RNFLT values. The on-responses showed an initial negative (N-on) followed by a positive (P-on), a late positive (LP-on) and a late negative responses (LN-on). The off-responses showed an initial positive (P-off) a late positive (LP-off) and a late negative response (LN-off). The addition of on- and off-responses revealed an initial positive (P-add) and a late negative response (LN-add). The on-response components (N-on, P-on and LN-on) in the glaucoma patients were relatively similar to those of the control subjects. However, the LP-on was significantly elevated (p = 0.03) in perimetric patients. The LP-off was significantly elevated (p < 0.001), and the amplitude of LN-off was significantly reduced in perimetric patients (p = 0.02). The LN-add amplitude was significantly reduced (p < 0.001) and delayed (p = 0.03) in perimetric patients. The amplitudes of the LN-off and LN-add ERG components were significantly correlated with the PhNR in the flash ERG (LN-off: p = 0.01; LN-add: p < 0.001) and with RNFLT (LN-off: p = 0.006; LN-add: p = 0.001). On- and off-response ERGs and their response asymmetries, elicited by sawtooth stimuli, are altered in the glaucoma patients. The late components are affected. Changes in the late negative components are correlated with structural and other functional changes.


Asunto(s)
Electrorretinografía , Glaucoma de Ángulo Abierto/fisiopatología , Enfermedades del Nervio Óptico/fisiopatología , Retina/fisiología , Anciano , Femenino , Humanos , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Fibras Nerviosas/patología , Estimulación Luminosa , Tomografía de Coherencia Óptica , Pruebas del Campo Visual , Campos Visuales
15.
PLoS One ; 17(10): e0272811, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36201426

RESUMEN

Glaucoma disease is characterized by an increased intraocular pressure (IOP), glaucomatous alterations of the optic disc and corresponding visual field defects. Even lowering the main risk factor IOP until an individual target level does not prevent this neurodegenerative disorder from proceeding. Several autoimmune mechanisms were discovered, partly showing a functionality. One of these autoimmune phenomena targets the ß2-adrenergic receptor (ß2-AR; i.e. agonistic autoantibodies; ß2-agAAb) and is linked to an elevated IOP and an impaired retinal microcirculation. As neurodegenerative disorder, Alzheimer's Disease (AD) is postulated to share a common molecular mechanism with glaucoma. In the present study we investigated autoimmune phenomena targeting the ß2-AR in patients with AD. Sera of the patients were analyzed in a rat cardiomyocyte bioassay for the presence of functional autoantibodies against ß2-AR. In addition, different species of amyloid beta (Aß) monomers were tested (Aß1-14, Aß10-25, Aß10-37 Aß1-40, Aß1-42, Aß28-40, and Aß-[Pyr]3-43). Our results demonstrate that none of the short-chain Aß (Aß1-14, Aß10-25, or Aß28-40) showed any agonistic or inhibitory effect on ß2-AR. Contrary, long-chain Aß-[Pyr]3-43, representing a major neurogenic plaque component, exerted an activation that after blocking by the ß2-AR antagonist ICI118.551, could be identified as that the effect was realized via the ß2-AR. Moreover, the long chain Aß1-40, Aß1-42, and Aß10-37, yet not the short-chain Aß peptides prevented the clenbuterol induced desensitization of the ß2-AR. In addition, we identified functional autoantibodies in the sera of AD patients, activating the ß2-AR, like the ß2-agAAb found in patients with glaucoma. As autoimmune mechanisms were reportedly involved in the pathogenesis of glaucoma and Alzheimer's Disease, we postulate that overstimulation of the ß2-AR pathway can induce an adrenergic overdrive, that may play an important role in the multifactorial interplay of neurodegenerative disorders.


Asunto(s)
Enfermedad de Alzheimer , Clenbuterol , Glaucoma , Animales , Ratas , Adrenérgicos , Péptidos beta-Amiloides/metabolismo , Autoanticuerpos , Presión Intraocular , Receptores Adrenérgicos
16.
Biology (Basel) ; 10(6)2021 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-34208432

RESUMEN

Purpose: Drugs with cardiovascular protective properties (statins, acetylsalicylic acid (ASS)) were assumed to have positive effects on patients suffering from glaucoma disease. The present retrospective study aimed to investigate the influence of statins, ASS or a combination of both on the glaucoma conversion and progression rate in glaucoma suspects and glaucoma patients with a 20-year follow-up period. Methods: A retrospective analysis of 199 eyes of 120 patients (63 male, 57 female) of the Erlanger Glaucoma Registry (EGR; ClinicalTrials.gov Identifier: NCT00494923; ISSN 2191-5008, CS-2011) was performed considering systemic therapy with statins, ASS or a combination of both: 107 eyes with ocular hypertension (OHT) and 92 eyes with pre-perimetric primary open-angle glaucoma (pre-POAG). All patients received an ophthalmological examination including morphometric and functional glaucoma diagnostics. Glaucoma conversion was defined as the conversion of OHT to pre-POAG. Glaucoma progression was defined as confirmed visual field loss. Data were shown as percentages. Statistical analysis was performed by Chi-Quadrat tests. Results: 1. Glaucoma conversion/progression was observed in 46.7% of the subjects, additionally in combination with hypercholesterinemia in 76.8%. 2. Statins: 27.3% of eyes under systemic statin therapy showed a conversion/progression. Patients taking statins ≥ 10 years yielded a reduced conversion/progression rate (p = 0.028, non-significant after Bonferroni-Holm). 3. ASS: 34.7% of eyes under systemic ASS therapy showed a conversion/progression. A significantly lower conversion/progression rate was observed after ASS therapy ≥ 12 years (p = 0.017, significant after Bonferroni-Holm). 4. ASS and statins: 25.0% of eyes under combined therapy showed a conversion/progression. A significantly reduced conversion/progression rate was reached after 8 years of combined therapy (p = 0.049, non-significant after Bonferroni-Holm). Conclusions: Patients with ocular hypertension and early glaucoma seem to benefit from adjuvant cardiovascular protective therapy. However, the benefits and disadvantages of treatment with statins and/or ASS should be kept in mind. Thus, a thorough risk-benefit evaluation has to be performed for each patient individually to avoid unwanted side effects.

17.
Front Med (Lausanne) ; 8: 684676, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34150817

RESUMEN

Purpose: The aim of the present study was to investigate the diagnostic power of RGCL in the macula quantitatively and qualitatively by using a conventional and extended elliptic grid with deviation maps. Subjects and Methods: Thickness of RGCL was measured using SPECTRALIS® OCT (Heidelberg Engineering, Heidelberg, Germany) in 150 eyes of 150 subjects of the Erlangen Glaucoma Registry (EGR; NTC00494923): 26 ocular hypertension (OHT), 39 pre-perimetric open-angle glaucoma (pre-OAG), 19 normal tension glaucoma (NTG), 34 primary open-angle glaucoma (POAG), 16 secondary open-angle glaucoma (SOAG), and 16 controls. Analysis of RGCL was done quantitatively (global value, GV) and qualitatively (qualitative total value, QTV) by using a color-coded point score for data of the common elliptic macular grid of deviation maps. Furthermore, qualitative analysis of RGCL was done for an extended elliptic macula grid (extended qualitative total value, eQTV). Receiver operating characteristic (ROC) curves were calculated for the conventional and the enlarged macular grid for all subjects' groups. Results: GV of RGCL thickness differed significantly between pre-OAG (p < 0.05), NTG (p < 0.001), POAG (p < 0.001), SOAG (p < 0.001), yet not OHT (p > 0.05) and controls, respectively. Quantitative ROC analysis of GV showed AUC of 0.965 (SOAG), 0.942 (POAG), 0.916 (NTG), 0.772 (pre-OAG), and 0.526 (OHT). QTV differed significantly between pre-POAG (p < 0.05), NTG (p < 0.001), POAG (p < 0.001), SOAG (p < 0.001), yet not OHT (p > 0.05) and controls, respectively. Qualitative ROC analysis of QTV showed AUCs of 0.908 (NTG) 0.914 (POAG), 0.930 (SOAG), 0.734 (pre-POAG), and 0.519 (OHT). Implementation of eQTV yielded even higher AUCs for NTG (0.919), POAG (0.969), and SOAG (0.973) compared to GV. Similar AUCs of eQTV and GV were observed for OHT (0.514) and pre-OAG (0.770). Conclusion: The results of the present study showed that quantitative and qualitative analysis of RGCL thickness yielded similar diagnostic impacts compared to RNFL. Qualitative analysis might be a quick and easy useable tool for clinical all-day life. The present data suggest that analysis of an extended macula region might improve its diagnostic impact.

18.
Invest Ophthalmol Vis Sci ; 62(6): 17, 2021 05 03.
Artículo en Inglés | MEDLINE | ID: mdl-33988692

RESUMEN

Purpose: The purpose of this study was to characterize summation of temporal L- and M-cone contrasts in the parvo- (P-) and magnocellular (M-) pathways in glaucoma and the relationship between the respective temporal contrast sensitivities (tCS) and clinical parameters. Methods: Perifoveal tCS to isolated or combined L- and M-cone contrasts (with different contrast ratios, and therefore different luminance and chromatic components) were measured at different temporal frequencies (at 1 or 2 Hz and at 20 Hz) using triple silent substitution in 73 subjects (13 healthy, 25 with glaucoma, and 35 with perimetric glaucoma). A vector summation model was used to analyze whether perception was driven by the P-pathway, the M-pathway, or both. Using this model, L- and M-cone input strengths (AL, AM) and phase differences between L- and M-cone inputs were estimated. Results: Perception was always mediated by the P-pathway at low frequencies, as indicated by a median phase angle of 179.84 degrees (cone opponency) and a median AL/AM ratio of 1.04 (balanced L- and M-cone input strengths). In contrast, perception was exclusively mediated by the M-pathway at higher frequencies (input strength not balanced: AL/AM = 2.94, median phase angles = 130.17 degrees). Differences in phase were not significant between diagnosis groups (Kruskal-Wallis = 0.092 for P- and 0.35 for M-pathway). We found differences between groups only for the M-pathway (L-cone tCS deviations at 20 Hz were significantly lower in the patients with glaucoma P = 0.014, with a strong tendency in M-cones P = 0.049). L-cone driven tCS deviations at 20 Hz were linearly correlated with perimetric mean defect (MD) and quadratically correlated with retinal nerve fiber layer (RNFL) thickness. Conclusions: Unaltered phase angles between L- and M-cone inputs in glaucoma indicated intact temporal processing. Only in the M-pathway, contrast sensitivity deviations were closely related to diagnosis group, MD, and RNFL thickness, indicating M-pathway involvement.


Asunto(s)
Opsinas de los Conos/fisiología , Sensibilidad de Contraste/fisiología , Cuerpos Geniculados/fisiología , Glaucoma de Ángulo Abierto/fisiopatología , Células Fotorreceptoras Retinianas Conos/fisiología , Células Ganglionares de la Retina/fisiología , Adulto , Anciano , Femenino , Humanos , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Tomografía de Coherencia Óptica , Pruebas del Campo Visual , Campos Visuales/fisiología , Vías Visuales/fisiología
19.
Invest Ophthalmol Vis Sci ; 62(9): 14, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-34241626

RESUMEN

Purpose: To compare the electroretinographical (ERG) responses elicited by L- and M-cone isolating ON- and OFF-sawtooth stimuli in normal subjects and glaucoma patients. Methods: Twenty-one normal subjects and 44 primary open-angle glaucoma patients participated in the study. L- and M-cone isolating (18% cone contrast; 284 cd/m2) rapid ON- and rapid OFF-sawtooth (4 Hz) stimuli with two stimulus sizes (full-field (FF) and central 70° diameter) were generated using the triple silent substitution technique. ON- and OFF-response asymmetries were studied by adding the two (to obtain L-add and M-add responses). The initial positive (P) and subsequent late negative (LN) components of the L-add and M-add ERGs were compared between the subject groups and correlated with retinal nerve fiber layer thickness (RNFLT) and pattern ERG responses. Results: The responses to L-ON and to M-OFF stimuli and vice versa resembled each other particularly with 70° stimuli. The PL-add amplitudes were not significantly different between the normal subjects and glaucoma patients, whereas the LNL-add amplitude was significantly (P < 0.01) smaller in the glaucoma patients. Both PM-add and LNM-add were not significantly different between the subject groups. The PERG amplitude with 0.8° check sizes and the 0.8°/16° amplitude ratio (PERG ratio) were significantly (P < 0.05) different between the subject groups. The 70° LNL-add amplitude and the 0.8° PERG amplitude were significantly correlated with RNFLT. Conclusions: The ERGs to 70° cone isolating sawtooth stimuli reflect cone opponency. The cone opponent ERG responses were not significantly different between glaucoma patients and normal subjects. Luminance driven L-add responses were significantly different, indicating that central luminance signals are mainly affected in glaucoma.


Asunto(s)
Electrorretinografía/métodos , Glaucoma de Ángulo Abierto/fisiopatología , Retina/fisiopatología , Células Fotorreceptoras Retinianas Conos/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Glaucoma de Ángulo Abierto/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Estimulación Luminosa/métodos
20.
Biomed Opt Express ; 12(12): 7434-7444, 2021 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-35003844

RESUMEN

Glaucoma is among the leading causes of irreversible blindness worldwide. If diagnosed and treated early enough, the disease progression can be stopped or slowed down. Therefore, it would be very valuable to detect early stages of glaucoma, which are mostly asymptomatic, by broad screening. This study examines different computational features that can be automatically deduced from images and their performance on the classification task of differentiating glaucoma patients and healthy controls. Data used for this study are 3 x 3 mm en face optical coherence tomography angiography (OCTA) images of different retinal projections (of the whole retina, the superficial vascular plexus (SVP), the intermediate capillary plexus (ICP) and the deep capillary plexus (DCP)) centered around the fovea. Our results show quantitatively that the automatically extracted features from convolutional neural networks (CNNs) perform similarly well or better than handcrafted ones when used to distinguish glaucoma patients from healthy controls. On the whole retina projection and the SVP projection, CNNs outperform the handcrafted features presented in the literature. Area under receiver operating characteristics (AUROC) on the SVP projection is 0.967, which is comparable to the best reported values in the literature. This is achieved despite using the small 3 × 3 mm field of view, which has been reported as disadvantageous for handcrafted vessel density features in previous works. A detailed analysis of our CNN method, using attention maps, suggests that this performance increase can be partially explained by the CNN automatically relying more on areas of higher relevance for feature extraction.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA