Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Europace ; 25(3): 1025-1034, 2023 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-36635857

RESUMEN

AIMS: Little is known about patients with right bundle branch block (RBBB)-ventricular tachycardia (VT) and arrhythmogenic cardiomyopathy (ACM). Our aims were: (i) to describe electrocardiogram (ECG) characteristics of sinus rhythm (SR) and VT; (ii) to correlate SR with RBBB-VT ECGs; and (iii) to compare VT ECGs with electro-anatomic mapping (EAM) data. METHODS AND RESULTS: From the European Survey on ACM, 70 patients with spontaneous RBBB-VT were included. Putative left ventricular (LV) sites of origin (SOOs) were estimated with a VT-axis-derived methodology and confirmed by EAM data when available. Overall, 49 (70%) patients met definite Task Force Criteria. Low QRS voltage predominated in lateral leads (n = 37, 55%), but QRS fragmentation was more frequent in inferior leads (n = 15, 23%). T-wave inversion (TWI) was equally frequent in inferior (n = 28, 42%) and lateral (n = 27, 40%) leads. TWI in inferior leads was associated with reduced LV ejection fraction (LVEF; 46 ± 10 vs. 53 ± 8, P = 0.02). Regarding SOOs, the inferior wall harboured 31 (46%) SOOs, followed by the lateral wall (n = 17, 25%), the anterior wall (n = 15, 22%), and the septum (n = 4, 6%). EAM data were available for 16 patients and showed good concordance with the putative SOOs. In all patients with superior-axis RBBB-VT who underwent endo-epicardial VT activation mapping, VT originated from the LV. CONCLUSIONS: In patients with ACM and RBBB-VT, RBBB-VTs originated mainly from the inferior and lateral LV walls. SR depolarization and repolarization abnormalities were frequent and associated with underlying variants.


Asunto(s)
Cardiomiopatías , Taquicardia Ventricular , Humanos , Bloqueo de Rama , Taquicardia Ventricular/etiología , Taquicardia Ventricular/complicaciones , Ventrículos Cardíacos , Electrocardiografía , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico
2.
Europace ; 24(2): 285-295, 2022 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-34491328

RESUMEN

AIMS: In arrhythmogenic cardiomyopathy (ACM), sustained ventricular tachycardia (VT) typically displays a left bundle branch block (LBBB) morphology while a right bundle branch block (RBBB) morphology is rare. The present study assesses the VT morphology in ACM patients with sustained VT and their clinical and genetic characteristics. METHODS AND RESULTS: Twenty-six centres from 11 European countries provided information on 954 ACM patients who had ≥1 episode of sustained VT spontaneously documented during patients' clinical course. Arrhythmogenic cardiomyopathy was defined according to the 2010 Task Force Criteria, and VT morphology according to the QRS pattern in V1. Overall, 882 (92.5%) patients displayed LBBB-VT alone and 72 (7.5%) RBBB-VT [alone in 42 (4.4%) or in combination with LBBB-VT in 30 (3.1%)]. Male sex prevalence was 79.3%, 88.1%, and 56.7% in the LBBB-VT, RBBB-VT, and LBBB + RBBB-VT groups, respectively (P = 0.007). First RBBB-VT occurred 5 years after the first LBBB-VT (46.5 ± 14.4 vs 41.1 ± 15.8 years, P = 0.011). An implanted cardioverter-defibrillator was more frequently implanted in the RBBB-VT (92.9%) and the LBBB + RBBB-VT groups (90%) than in the LBBB-VT group (68.1%) (P < 0.001). Mutations in PKP2 predominated in the LBBB-VT (65.2%) and the LBBB + RBBB-VT (41.7%) groups while DSP mutations predominated in the RBBB-VT group (45.5%). By multivariable analysis, female sex was associated with LBBB + RBBB-VT (P = 0.011) while DSP mutations were associated with RBBB-VT (P < 0.001). After a median follow-up of 103 (51-185) months, death occurred in 106 (11.1%) patients with no intergroup difference (P = 0.176). CONCLUSION: RBBB-VT accounts for a significant proportion of sustained VTs in ACM. Sex and type of pathogenic mutations were associated with VT type, female sex with LBBB + RBBB-VT, and DSP mutation with RBBB-VT.


Asunto(s)
Cardiomiopatías , Taquicardia Ventricular , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/epidemiología , Bloqueo de Rama/terapia , Cardiomiopatías/complicaciones , Cardiomiopatías/epidemiología , Cardiomiopatías/genética , Electrocardiografía , Femenino , Humanos , Masculino , Prevalencia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/genética
3.
Lancet ; 391(10115): 59-69, 2018 01 06.
Artículo en Inglés | MEDLINE | ID: mdl-29107324

RESUMEN

BACKGROUND: On-pump cardiac surgery provokes a predictable perioperative myocardial ischaemia-reperfusion injury which is associated with poor clinical outcomes. We determined the occurrence of time-of-the-day variation in perioperative myocardial injury in patients undergoing aortic valve replacement and its molecular mechanisms. METHODS: We studied the incidence of major adverse cardiac events in a prospective observational single-centre cohort study of patients with severe aortic stenosis and preserved left ventricular ejection fraction (>50%) who were referred to our cardiovascular surgery department at Lille University Hospital (Lille, France) for aortic valve replacement and underwent surgery in the morning or afternoon. Patients were matched into pairs by propensity score. We also did a randomised study, in which we evaluated perioperative myocardial injury and myocardial samples of patients randomly assigned (1:1) via permuted block randomisation (block size of eight) to undergo isolated aortic valve replacement surgery either in the morning or afternoon. We also evaluated human and rodent myocardium in ex-vivo hypoxia-reoxygenation models and did a transcriptomic analysis in myocardial samples from the randomised patients to identify the signalling pathway(s) involved. The primary objective of the study was to assess whether myocardial tolerance of ischaemia-reperfusion differed depending on the timing of aortic valve replacement surgery (morning vs afternoon), as measured by the occurrence of major adverse cardiovascular events (cardiovascular death, myocardial infarction, and admission to hospital for acute heart failure). The randomised study is registered with ClinicalTrials.gov, number NCT02812901. FINDINGS: In the cohort study (n=596 patients in matched pairs who underwent either morning surgery [n=298] or afternoon surgery [n=298]), during the 500 days following aortic valve replacement, the incidence of major adverse cardiac events was lower in the afternoon surgery group than in the morning group: hazard ratio 0·50 (95% CI 0·32-0·77; p=0·0021). In the randomised study, 88 patients were randomly assigned to undergo surgery in the morning (n=44) or afternoon (n=44); perioperative myocardial injury assessed with the geometric mean of perioperative cardiac troponin T release was significantly lower in the afternoon group than in the morning group (estimated ratio of geometric means for afternoon to morning of 0·79 [95% CI 0·68-0·93; p=0·0045]). Ex-vivo analysis of human myocardium revealed an intrinsic morning-afternoon variation in hypoxia-reoxygenation tolerance, concomitant with transcriptional alterations in circadian gene expression with the nuclear receptor Rev-Erbα being highest in the morning. In a mouse Langendorff model of hypoxia-reoxygenation myocardial injury, Rev-Erbα gene deletion or antagonist treatment reduced injury at the time of sleep-to-wake transition, through an increase in the expression of the ischaemia-reperfusion injury modulator CDKN1a/p21. INTERPRETATION: Perioperative myocardial injury is transcriptionally orchestrated by the circadian clock in patients undergoing aortic valve replacement, and Rev-Erbα antagonism seems to be a pharmacological strategy for cardioprotection. Afternoon surgery might provide perioperative myocardial protection and lead to improved patient outcomes compared with morning surgery. FUNDING: Fondation de France, Fédération Française de Cardiologie, EU-FP7-Eurhythdia, Agence Nationale pour la Recherche ANR-10-LABX-46, and CPER-Centre Transdisciplinaire de Recherche sur la Longévité.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Ritmo Circadiano , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Daño por Reperfusión Miocárdica/epidemiología , Miembro 1 del Grupo D de la Subfamilia 1 de Receptores Nucleares/metabolismo , Complicaciones Posoperatorias/epidemiología , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/metabolismo , Estudios de Casos y Controles , Estudios de Cohortes , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Daño por Reperfusión Miocárdica/metabolismo , Miembro 1 del Grupo D de la Subfamilia 1 de Receptores Nucleares/antagonistas & inhibidores , Complicaciones Posoperatorias/metabolismo , Puntaje de Propensión , Transducción de Señal , Resultado del Tratamiento
4.
Eur Radiol ; 29(6): 3027-3035, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30402702

RESUMEN

OBJECTIVE: To evaluate whether the epicardial adipose tissue (EAT) phenotype is associated with the electrophysiological properties of adjacent atrial myocardium in patients with atrial fibrillation (AF). METHODS: Between January and May 2017, 30 consecutive patients referred for a first AF catheter ablation were prospectively included. For each patient, a pre-procedural computed tomography scan was performed to assess total and left atrial (LA) EAT amount and radiodensity. A detailed point-by-point voltage mapping using an electroanatomic mapping system was realized to assess the presence of LA low-voltage zone (LVZ). RESULTS: Ten patients (33.3%) presented at least one LVZ. Older age (65 ± 7 vs. 58 ± 10 years, p = 0.05) was the only clinical parameter associated with LVZ. Despite no greater LA-EAT thickness by CT scan (3.0 [2.6-3.5] mm vs. 2.8 [2.2-3.1] mm, p = 0.354), patients with LA-LVZ presented significantly lower LA-EAT radiodensity than patients with no LA-LVZ (- 101.8 ± 12.5 HU vs. - 90.4 ± 6.3 HU, p = 0.004). No difference between total-EAT volume (131 ± 61 cm3 vs.107 ± 58 cm3, p = 0.361) and total-EAT radiodensity (- 106.8 ± 4.3 HU vs. - 102.4 ± 6.9 HU, p = 0.119) was found. CONCLUSION: Low LA-EAT radiodensity is associated with the presence of LVZ in patients with medical history of AF. KEY POINTS: • Cardiovascular risk factors are associated with low adipose tissue computed tomography attenuation. • Epicardial adipose tissue (EAT) has emerged as an important factor in the pathogenesis of metabolic-related cardiac diseases such as atrial fibrillation. • We showed that low left atrial EAT attenuation is associated with the presence of low-voltage zone, a surrogate for atrial fibrosis, within the adjacent myocardium.


Asunto(s)
Tejido Adiposo/patología , Fibrilación Atrial/diagnóstico , Mapeo del Potencial de Superficie Corporal/métodos , Atrios Cardíacos/diagnóstico por imagen , Pericardio/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Anciano , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Femenino , Estudios de Seguimiento , Atrios Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo
5.
Europace ; 21(12): 1833-1842, 2019 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-31436840

RESUMEN

AIMS: Limited data exist on the efficacy of catheter ablation (CA) for sport-related atrial fibrillation (AF). Impact of sports practice resumption post-CA remains unknown. We aimed to determine AF CA efficacy in athletes vs. non-athletes, and to assess the impact of sport practice resumption. METHODS AND RESULTS: From 1153 first-time AF CA performed between 2009 and 2017, 73 athletes were matched with 73 sedentary patients based on age, sex, and closest CA procedure date. Athletes were defined as performing ≥6 h/week of vigorous sports to achieve ≥2000 h accumulated lifetime sports activity. They were mostly males (93.2%) with a mean age of 55 ± 9.8 years. Before CA, athletes practiced 10.2 ± 3.9 h/week of vigorous exercise vs. 4.6 ± 3.4 after CA. Within first year after CA, physical activity was stopped in 12 (16.4%) athletes, lowered in 45 (61.9%), and resumed at same intensity in 16 (21.9%). Athletes and non-athletes suffered from same AF recurrence rates during 5-year follow-up after CA: 38 (52.0%) vs. 35 (47.9%), respectively [adjusted hazard ratio (HR) on age, body mass index (BMI), obstructive sleep apnoea (OSA), and reduced left ventricular ejection fraction (LVEF), 1.17 (0.70-1.97, P = 0.54)]. No significant impact of physical activity resumption status was found regarding AF recurrence rates at 1-year and beyond (P = 0.60). Procedure effectiveness was significantly lower in athletes with non-paroxysmal AF [adjusted on age, BMI, reduced LVEF, and OSA HR 2.36 (confidence interval 1.19-4.70), P = 0.01]. CONCLUSION: Sports practice before and after CA has no significant impact on AF recurrence rates in athletes within 5-year after AF CA.


Asunto(s)
Atletas , Fibrilación Atrial/cirugía , Remodelación Atrial , Ablación por Catéter , Volver al Deporte , Remodelación Ventricular , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Estudios de Casos y Controles , Ecocardiografía , Entrenamiento Aeróbico , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Recurrencia , Factores de Riesgo , Conducta Sedentaria , Volumen Sistólico , Resultado del Tratamiento
6.
Pacing Clin Electrophysiol ; 42(3): 349-355, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30609077

RESUMEN

INTRODUCTION: Several clinical studies have demonstrated that remote monitoring (RM) offers potential benefits in transvenous implantable cardioverter defibrillator (ICD). The potential interest of RM in subcutaneous-ICD (S-ICD) recipients has never been evaluated. The aim of this study was to evaluate the alert burden and its clinical relevance in a prospective cohort of S-ICD recipients. METHODS: We prospectively and consecutively enrolled all patients undergoing S-ICD implantation at Lille University Hospital from September 2015 to January 2017 and gave them a LATITUDE™ NXT RM system. The relevance of transmissions was assessed by the following ratio: number of transmissions leading to reaction or intervention per patient/number of transmissions per patient. RESULTS: From September 2015 to January 2017, 69 patients were enrolled with a mean follow-up of 415 ± 96.3 days. The mean age was 44.6 ± 15.6 years old, and 25% (n = 17) had ischemic cardiomyopathy. At the end of follow-up, 12% of the patients had events recorded by RM. These events were related to nine ICD shocks and eight untreated events. A total of 1,423 transmissions were collected. Most of these transmissions were patient-initiated without any event (77%, n = 1,096) or scheduled without any event (19%, n = 272). Only 3.2% ± 1.1 of the transmissions per patient led to reactions or interventions. CONCLUSION: On the basis of the current method of transmitting, S-ICD RM allowed detection of relevant events in 12% of patients but generated a high unactionable transmission burden. As a result of these findings, efforts should be made to optimize transmissions considering automatic transmissions and to focus on patient education.


Asunto(s)
Cardiomiopatías/terapia , Desfibriladores Implantables , Tecnología de Sensores Remotos/métodos , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sistema de Registros
7.
Europace ; 20(2): 362-369, 2018 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-28017936

RESUMEN

Aims: Studies assessing radiofrequency ablation (RFA) of ventricular tachycardia (VT) in arrhythmogenic right ventricular cardiomyopathy (ARVC) report VT recurrences, but have not evaluated the impact of RFA on relevant clinical events during follow-up. We aimed to investigate relevant RFA outcomes in a multicentric registry. Methods and results: This study included 49 patients with ARVC (46 with definite diagnosis, 3 with borderline diagnosis according to revised Task Force Criteria) who underwent 92 RFA procedures (83 endocardial, 9 combined endo-epicardial) between 1999-2015. Ventricular tachycardia recurrences and VT burden were assessed after each procedure or after the last RFA. Over a mean follow-up of 64 ± 51 months, VT-free survival was 37% at 1 year, 19% at 5 years, and 14% at 10 years. Ventricular tachycardia burden was significantly reduced after one procedure (23 vs. 11 VT episodes/year, P < 0.01) and after the last RFA (14 vs. 2 VT episodes/year, P < 0.01). Over a mean follow-up of 49 ± 52 months, clinical response after the last RFA (freedom from sudden cardiac death, VT requiring hospitalization, or heart transplantation) was 86% at 1 year, 69% at 5 years, and 60% at 10 years. Clinical response was associated with right ventricular dysfunction (RVD) and low numbers of mappable VT before the first RFA. Conclusion: RFA was predominantly targeted at the endocardial surface. Ventricular tachycardia recurrences were common, but few ARVC patients experienced major clinical events during follow-up. Further studies should investigate the benefit of extensive substrate ablation combined with endo-epicardial strategies.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica/complicaciones , Ablación por Catéter , Taquicardia Ventricular/cirugía , Adulto , Displasia Ventricular Derecha Arritmogénica/diagnóstico , Displasia Ventricular Derecha Arritmogénica/fisiopatología , Ablación por Catéter/efectos adversos , Supervivencia sin Enfermedad , Femenino , Francia , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
8.
Europace ; 18(12): 1809-1817, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26711741

RESUMEN

AIMS: Despite increased use of remote monitoring (RM) to follow up implantable cardioverter-defibrillator (ICD) recipients, many patients still receive ICD shocks in the community and present to the emergency department. Our aim was to identify the best predictors of impending shock delivery that can be measured with an ICD and to identify the most appropriate activities to alert physicians to during RM follow-up. METHODS AND RESULTS: All patients presenting to our institution for ICD shock, from November 2011 to November 2014, were enrolled in this prospective study. Patient characteristics, investigation results, and details of electrical activities from ICD interrogation were recorded at presentation. Presentations were classified as potentially avoidable if activities from a list of set criteria were apparent more than 48 h before index shock. Univariate and multivariate analyses were then used to identify predictors of potentially avoidable shocks. In total, 109 emergency presentations were recorded in 90 patients (male: 85%; 57 ± 16 years; ischaemic cardiomyopathy: 49%; LVEF: 34 ± 13%; electrical storm: 40%), of which 26 (24%) were potentially avoidable. Antitachycardia pacing (ATP) episodes were the most important predictor of impending shock. Potentially avoidable shocks were preceded by more episodes of ATP than unavoidable shocks (13 [3-67] vs. 3 [0-10]; P < 0.001). Patients followed up with RM systems configured to generate alerts following ATP delivery experienced significantly less ICD shocks (24 vs. 16%, P < 0.01). CONCLUSION: Remote monitoring systems that generate alerts following ATP delivery could reduce emergency presentations for ICD shock by 24%, as ATP is a key predictor of impending shock delivery.


Asunto(s)
Estimulación Cardíaca Artificial/efectos adversos , Desfibriladores Implantables , Cardioversión Eléctrica/efectos adversos , Tecnología de Sensores Remotos , Taquicardia Ventricular/terapia , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Cardioversión Eléctrica/instrumentación , Electrocardiografía , Servicios Médicos de Urgencia , Femenino , Francia , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico/métodos , Análisis Multivariante , Isquemia Miocárdica/epidemiología , Isquemia Miocárdica/etiología , Estudios Prospectivos , Telemedicina , Disfunción Ventricular Izquierda/epidemiología , Disfunción Ventricular Izquierda/etiología , Adulto Joven
9.
Europace ; 18(6): 820-7, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26498163

RESUMEN

AIMS: Lead fractures in implantable cardioverter-defibrillator (ICD) patients may cause inappropriate shocks (ISs). An early diagnosis is essential to prevent adverse clinical events. Implantable cardioverter-defibrillator remote monitoring (RM) permits prompt detection of lead fracture. Limited data define the impact of RM on ISs specifically related to lead fracture. We sought to compare the number of ISs related to lead fracture in patients with vs. without RM follow-up. METHODS AND RESULTS: We checked the registry of our institution and collected, between July 2007 and June 2014, 115 cases of right ventricular lead fractures. All relevant data were documented from patients' files, device-interrogation printouts and electronic records, and remote transmissions databases when applicable. We assessed the ISs that were related to lead fracture. The first study endpoint was the number of ISs per shocked patient. Among the 82 patients with conventional follow-up (CFU) and the 33 patients with RM, a first IS occurred to 32.9% (n = 27) and 30.3% (n = 10, P = 0.83) of the patients, respectively. Shocked patients in the RM group underwent significantly fewer ISs with a mean of 6 ± 2 shocks per patient [median of 3.5 shocks (2-8)] than those in the CFU group with a mean of 18 ± 5 shocks per patient [median of 10 shocks (5-22), P = 0.03]. CONCLUSION: Remote monitoring helps to reduce the burden of ISs related to ICD lead fractures.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Cardioversión Eléctrica/efectos adversos , Falla de Equipo , Tecnología de Sensores Remotos , Femenino , Estudios de Seguimiento , Francia , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros
10.
Eur Heart J ; 35(22): 1479-85, 2014 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-24536081

RESUMEN

AIMS: Patients with well-tolerated sustained monomorphic ventricular tachycardia (SMVT) and left ventricular ejection fraction (LVEF) over 30% may benefit from a primary strategy of VT ablation without immediate need for a 'back-up' implantable cardioverter-defibrillator (ICD). METHODS AND RESULTS: One hundred and sixty-six patients with structural heart disease (SHD), LVEF over 30%, and well-tolerated SMVT (no syncope) underwent primary radiofrequency ablation without ICD implantation at eight European centres. There were 139 men (84%) with mean age 62 ± 15 years and mean LVEF of 50 ± 10%. Fifty-five percent had ischaemic heart disease, 19% non-ischaemic cardiomyopathy, and 12% arrhythmogenic right ventricular cardiomyopathy. Three hundred seventy-eight similar patients were implanted with an ICD during the same period and serve as a control group. All-cause mortality was 12% (20 patients) over a mean follow-up of 32 ± 27 months. Eight patients (40%) died from non-cardiovascular causes, 8 (40%) died from non-arrhythmic cardiovascular causes, and 4 (20%) died suddenly (SD) (2.4% of the population). All-cause mortality in the control group was 12%. Twenty-seven patients (16%) had a non-fatal recurrence at a median time of 5 months, while 20 patients (12%) required an ICD, of whom 4 died (20%). CONCLUSION: Patients with well-tolerated SMVT, SHD, and LVEF > 30% undergoing primary VT ablation without a back-up ICD had a very low rate of arrhythmic death and recurrences were generally non-fatal. These data would support a randomized clinical trial comparing this approach with others incorporating implantation of an ICD as a primary strategy.


Asunto(s)
Ablación por Catéter/métodos , Taquicardia Ventricular/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Ablación por Catéter/mortalidad , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos , Volumen Sistólico/fisiología , Taquicardia Ventricular/mortalidad , Taquicardia Ventricular/fisiopatología , Resultado del Tratamiento , Adulto Joven
11.
J Cardiovasc Electrophysiol ; 25(7): 763-70, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24602062

RESUMEN

INTRODUCTION: Inappropriate shocks remain a highly challenging complication of implantable cardioverter defibrillators (ICD). We examined whether automatic wireless remote monitoring (RM) of ICD, by providing early notifications of triggering events, lowers the incidence of inappropriate shocks. METHODS AND RESULTS: We studied 433 patients randomly assigned to RM (n = 221; active group) versus ambulatory follow-up (n = 212; control group). Patients in the active group were seen in the ambulatory department once a year, unless RM reported an event requiring an earlier ambulatory visit. Patients in the control group were seen in the ambulatory department every 6 months. The occurrence of first and further inappropriate shocks, and their causes in each group were compared. The characteristics of the study groups, including pharmaceutical regimens, were similar. Over a follow-up of 27 months, 5.0% of patients in the active group received ≥1 inappropriate shocks versus 10.4% in the control group (P = 0.03). A total of 28 inappropriate shocks were delivered in the active versus 283 in the control group. Shocks were triggered by supraventricular tachyarrhythmias (SVTA) in 48.5%, noise oversensing in 21.2%, T wave oversensing in 15.2%, and lead dysfunction in 15.2% of patients. The numbers of inappropriate shocks delivered per patient, triggered by SVTA and by lead dysfunction, were 74% and 98% lower, respectively, in the active than in the control group. CONCLUSION: RM was highly effective in the long-term prevention of inappropriate ICD shocks.


Asunto(s)
Desfibriladores Implantables , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/instrumentación , Traumatismos por Electricidad/prevención & control , Falla de Prótesis , Tecnología de Sensores Remotos , Telemedicina/métodos , Anciano , Atención Ambulatoria , Diagnóstico Precoz , Traumatismos por Electricidad/diagnóstico , Traumatismos por Electricidad/etiología , Traumatismos por Electricidad/fisiopatología , Femenino , Francia , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Diseño de Prótesis , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
12.
Europace ; 16(8): 1181-8, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24614572

RESUMEN

AIMS: The Effectiveness and Cost of ICD follow-up Schedule with Telecardiology (ECOST) trial evaluated prospectively the economic impact of long-term remote monitoring (RM) of implantable cardioverter defibrillators (ICDs). METHODS AND RESULTS: The analysis included 310 patients randomly assigned to RM (active group) vs. ambulatory follow-ups (control group). Patients in the active group were seen once a year unless the system reported an event mandating an ambulatory visit, while patients in the control group were seen in the ambulatory department every 6 months. The costs of each follow-up strategy were compared, using the actual billing documents issued by the French health insurance system, including costs of (i) (a) ICD-related ambulatory visits and transportation, (b) other ambulatory visits, (c) cardiovascular treatments and procedures, and (ii) hospitalizations for the management of cardiovascular events. The ICD and RM system costs were calculated on the basis of the device remaining longevity at the end of the study. The characteristics of the study groups were similar. Over a follow-up of 27 months, the mean non-hospital costs per patient-year were €1695 ± 1131 in the active, vs. €1952 ± 1023 in the control group (P = 0.04), a €257 difference mainly due to device management. The hospitalization costs per patient-year were €2829 ± 6382 and €3549 ± 9714 in the active and control groups, respectively (P = 0.46). Adding the ICD to the non-hospital costs, the savings were €494 (P = 0.005) or, when the monitoring system was included, €315 (P = 0.05) per patient-year. CONCLUSION: From the French health insurance perspective, the remote management of ICD patients is cost saving. CLINICAL TRIALS REGISTRATION: NCT00989417, www.clinicaltrials.gov.


Asunto(s)
Atención Ambulatoria/economía , Desfibriladores Implantables/economía , Cardioversión Eléctrica/economía , Costos de la Atención en Salud , Telemedicina/economía , Telemetría/economía , Anciano , Ahorro de Costo , Análisis Costo-Beneficio , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/instrumentación , Femenino , Francia , Gastos en Salud , Costos de Hospital , Humanos , Reembolso de Seguro de Salud , Masculino , Persona de Mediana Edad , Visita a Consultorio Médico/economía , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Factores de Tiempo , Transporte de Pacientes/economía , Resultado del Tratamiento
13.
Europace ; 16(11): 1587-94, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24596396

RESUMEN

AIMS: To describe obstetric/neonatal and cardiac outcomes for a cohort of women carrying implantable cardioverter-defibrillators (ICDs) during pregnancy. METHODS AND RESULTS: All women in routine follow-up at our institution for ICD implantation who became pregnant between 2006 and 2013 were included in this study. All ICDs were pre-pectoral devices with bipolar endocardial leads. Obstetric/neonatal and cardiac outcomes were assessed during pregnancy and post-partum. Twenty pregnancies were conceived by 12 women carrying ICD devices, 14 of which resulted in live births and none in maternal death. Seven of these women had structural cardiomyopathies and five had channelopathies. No device-related complications were recorded. Twelve shocks (nine transthoracic and three from ICDs) were experienced during pregnancy by two women, one of whom miscarried shortly afterwards at 4 weeks gestation. One stillbirth, three miscarriages and one termination were recorded for women with long QT syndrome, repaired tetralogy of Fallot and repaired Laubry-Pezzi syndrome, respectively. Intrauterine growth restriction, low birth weight, and neonatal hypoglycaemia were recorded in four, three, and five pregnancies, respectively. CONCLUSIONS: Pregnancy had no effect on ICD operation and no evidence was found to link ICD carriage with adverse pregnancy outcomes, although one miscarriage may have been induced by ICD shock therapy. A worsening of cardiac condition occurs in specific cardiac diseases and ß-blocker therapy should be continued for all women carrying ICDs in pregnancy as the benefits outweigh the risks of taking this medication.


Asunto(s)
Cardiomiopatías/terapia , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Cardiopatías Congénitas/terapia , Complicaciones Cardiovasculares del Embarazo/terapia , Aborto Espontáneo/etiología , Antagonistas Adrenérgicos beta/uso terapéutico , Adulto , Cardiomiopatías/congénito , Cardiomiopatías/diagnóstico , Cardiomiopatías/fisiopatología , Progresión de la Enfermedad , Cardioversión Eléctrica/efectos adversos , Electrocardiografía , Femenino , Francia , Edad Gestacional , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/fisiopatología , Humanos , Nacimiento Vivo , Seguridad del Paciente , Embarazo , Complicaciones Cardiovasculares del Embarazo/diagnóstico , Complicaciones Cardiovasculares del Embarazo/fisiopatología , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
14.
Eur Heart J ; 34(8): 605-14, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23242192

RESUMEN

AIMS: The ECOST trial examined prospectively the long-term safety and effectiveness of home monitoring (HM) of implantable cardioverter defibrillators (ICD). METHODS AND RESULTS: The trial's primary objective was to randomly compare the proportions of patients experiencing ≥ 1 major adverse event (MAE), including deaths from all causes, and cardiovascular, procedure-related, and device-related MAE associated with HM (active group) vs. ambulatory follow-ups (control group) in a sample of 433 patients. The 221 patients assigned to the active group were seen once a year, unless HM reported an ICD dysfunction or a clinical event requiring an ambulatory visit, while the 212 patients in the control group underwent ambulatory visits every 6 months. The characteristics of the study groups were similar. Over a follow-up of 24.2 months, 38.5% of patients in the active and 41.5% in the control group experienced ≥ 1 MAE (P < 0.05 for non-inferiority). The overall number of shocks delivered was significantly lower in the active (n = 193) than in the control (n = 657) group (P < 0.05) and the proportion of patients who received inappropriate shocks was 52% lower in the active (n = 11) than in the control (n = 22) group (P < 0.05). At the end of the follow-up, the battery longevity was longer in the active group because of a lower number of capacitor charges (499 vs. 2081). CONCLUSION: Our observations indicate that long-term HM of ICD is at least as safe as standard ambulatory follow-ups with respect to a broad spectrum of MAE. It also lowered significantly the number of appropriate and inappropriate shocks delivered, and spared the device battery. Clinical trials registration NCT00989417.


Asunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables/efectos adversos , Atención Ambulatoria , Arritmias Cardíacas/mortalidad , Causas de Muerte , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Ambulatorio , Estudios Prospectivos , Consulta Remota , Resultado del Tratamiento
15.
Rev Prat ; 63(2): 193-7, 2013 Feb.
Artículo en Francés | MEDLINE | ID: mdl-23513777

RESUMEN

Atrial fibrillation occurs most of the time without any symptom. The first symptomatic episode may follow many silent episodes. The natural history of atrial fibrillation is relatively chaotic from paroxysmal to persistent and permanent atrial fibrillation. The consequence is that antithrombotic treatment depends on global thromboembolic risk and not on patient's perception of arrhythmia or sinus rhythm presentation. Unfortunately, the first appearance may be the most feared complication: stroke. Stroke due to atrial fibrillation are frequent, severe, with high mortality rate during hospitalization and during the following year. The severity of stroke during atrial fibrillation could explain a certain degree of cognitive decline. Heart failure is also a frequent atrial fibrillation complication due to sharing of common causes. Through those two complications, atrial fibrillation raises mortality rate. Less importantly, though leading to frequent hospitalizations, quality of life impairment is relatively frequent.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/patología , Fibrilación Atrial/complicaciones , Fibrilación Atrial/mortalidad , Trastornos del Conocimiento/epidemiología , Trastornos del Conocimiento/etiología , Demencia/epidemiología , Demencia/etiología , Progresión de la Enfermedad , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/mortalidad , Humanos , Pronóstico
16.
Pacing Clin Electrophysiol ; 35(10): 1209-16, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22817404

RESUMEN

BACKGROUND: Little is known about predictors of antitachycardia pacing (ATP) failure in implantable cardioverter defibrillator (ICD) recipients. Distance between the stimulation site and the ventricular tachycardia (VT) site of origin may critically affect ATP effectiveness. We hypothesized that ATP may be less effective in ICD patients who had basal VT than in those who had apical VT. METHODS: We reviewed data from 52 patients with sustained monomorphic VT and left ventricular disease referred for ICD implantation. ATP was delivered exclusively at the right ventricular apex. The clinical VTs site of origin (basal, midventricular, or apical) was determined in each patient, using 12-lead electrocardiogram. VTs episodes treated with ATP during the 1-year follow-up were studied. ATP success rate (%), defined as the ratio between the number of successful ATP sequences and the number of delivered ATP sequences, was determined in each patient. RESULTS: VT exit site was apical in 19 patients (36%), basal in 18 patients (35%), and midventricular in 15 patients (29%). In those 52 patients, 1,393 ATP sequences, delivered to treat 761 VT episodes, were analyzed. ATP success rate was found to be associated with the VT site of origin (median [interquartile range]): basal (33%[11-67]), midventricular (50%[37-100]), apical (100%[41-100]) (P = 0.027). Multivariate analysis identified basal VT site of origin as an independent predictor of ATP failure (P = 0.023). CONCLUSION: ATP is less effective in ICD patients who had basal VT than in those who had apical VT before ICD implantation.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Falla de Equipo , Taquicardia Ventricular/terapia , Anciano , Electrocardiografía/instrumentación , Electrocardiografía/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Taquicardia Ventricular/fisiopatología
17.
Pacing Clin Electrophysiol ; 35(5): 605-11, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22432791

RESUMEN

BACKGROUND: Management of antiplatelet therapy at the time of device implantation remains controversial. This study aimed to assess the risk of bleeding complications in patients receiving clopidogrel at the time of cardiac device surgery. METHODS: We performed a retrospective case-control study. Between 2004 and 2010, 101 consecutive patients receiving clopidogrel underwent cardiac device surgery (pacemaker or implantable cardioverter-defibrillator implantation, and generator replacement) in our institution. Controls were 1:1 matched on age, sex, device, type of procedure, number of leads implanted, and venous approach (cephalic or subclavian). A significant bleeding complication was defined as pocket hematoma requiring surgical evacuation or prolonged hospitalization, hemothorax, pericardial effusion, or tamponade. RESULTS: Bleeding complications occurred more frequently in patients receiving clopidogrel at the time of device procedure: 11.9% versus 4.0% (P = 0.037; odds radio [OR] 3.27 [1.02-10.5]). Significant bleeding complications were noted in 12 patients (11.9%) receiving clopidogrel, including two patients with pericardial effusion and one patient with hemothorax. Four controls (4.0%) had bleeding complications (three pocket hematomas and one pericardial effusion). The single factor associated with increased bleeding complications in patients receiving clopidogrel was subclavian puncture (P = 0.008). In the entire cohort (n = 202), multivariate analysis identified two independent predictors of significant bleeding complications: clopidogrel treatment at the time of surgery (P = 0.03; OR 3.7 [1.1-12.6]) and subclavian venous puncture (P = 0.03; OR 3.44 [1.1-10.4]). CONCLUSIONS: Clopidogrel treatment at the time of heart rhythm device procedures is associated with an increased risk of significant bleeding complications. Subclavian puncture seems to strongly increase hemorrhagic complications in this setting.


Asunto(s)
Terapia de Resincronización Cardíaca/estadística & datos numéricos , Hemorragia/epidemiología , Trombosis/epidemiología , Trombosis/prevención & control , Ticlopidina/análogos & derivados , Estudios de Casos y Controles , Clopidogrel , Comorbilidad , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos , Femenino , Francia/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Ticlopidina/uso terapéutico , Resultado del Tratamiento
18.
Healthcare (Basel) ; 10(8)2022 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-36011215

RESUMEN

INTRODUCTION: The choice of diagnostic tests in front of a given clinical case is a major part of medical reasoning. Failure to prescribe the right test can lead to serious diagnostic errors. Furthermore, unnecessary medical tests are a waste of money and could possibly generate injuries to patients, especially in family medicine. METHODS: In an effort to improve the training of our students to the choice of laboratory and imaging studies, we implemented a specific multiple-choice questions (MCQ), called comprehensive MCQ (cMCQ), with a fixed and high number of options matching various basic medical tests, followed by a certainty-based mark (CBM). This tool was used in the assessment of diagnostic test choice in various clinical cases of general practice in 456 sixth-year medical students. RESULTS: The scores were significantly correlated with the traditional exams (standard MCQ), with matched themes. The proportion of "cMCQ/CBM score" variance explained by "standard MCQ score" was 21.3%. The cMCQ placed students in a situation closer to practice reality than standard MCQ. In addition to its usefulness as an assessment tool, those tests had a formative value and allowed students to work on their ability to measure their doubt/certainty in order to develop a reflexive approach, required for their future professional practice. CONCLUSION: cMCQ followed by CBM is a feasible and reliable evaluation method for the assessment of diagnostic testing.

19.
Plast Reconstr Surg ; 149(3): 475e-484e, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35196687

RESUMEN

BACKGROUND: Teaching about craniofacial traumas is challenging given the complexity of the craniofacial anatomy and the necessity for good spatial representation skills. To solve these problems, three-dimensional printing seems to be an appropriate educative material. In this study, the authors conducted a randomized controlled trial. The authors' main objective was to compare the performance of the undergraduate medical students in an examination based on the teaching support: three-dimensionally printed models versus two-dimensional pictures. METHODS: All participants were randomly assigned to one of two groups using a random number table: the three-dimensionally-printed support group (three-dimensional group) or the two-dimensionally-displayed support group (two-dimensional group). All participants completed a multiple-choice question evaluation questionnaire on facial traumatology (first, a zygomatic bone fracture; then, a double mandible fracture). Sex and potential confounding factors were evaluated. RESULTS: Four hundred thirty-two fifth-year undergraduate medical students were enrolled in this study. Two hundred six students were allocated to the three-dimensional group, and 226 were allocated to the two-dimensional group. The three-dimensionally printed model was considered to be a better teaching material compared with two-dimensional support. The global mean score was 2.36 in the three-dimensional group versus 1.99 in the two-dimensional group (p = 0.008). Regarding teaching of biomechanical aspects, three-dimensionally-printed models provide better understanding (p = 0.015). Participants in both groups exhibited similar previous student educational achievements and visuospatial skills. CONCLUSIONS: This prospective, randomized, controlled educational trial demonstrated that incorporation of three-dimensionally-printed models improves medical students' understanding. This trial reinforces previous studies highlighting academic benefits in using three-dimensionally-printed models mostly in the field of understanding complex structures.


Asunto(s)
Traumatismos Craneocerebrales , Educación de Pregrado en Medicina/métodos , Modelos Anatómicos , Impresión Tridimensional , Cráneo/anatomía & histología , Cráneo/lesiones , Evaluación Educacional , Francia , Humanos , Estudios Prospectivos
20.
Eur Heart J Acute Cardiovasc Care ; 11(5): 431-439, 2022 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-35512138

RESUMEN

AIMS: For assessing predictors of early mortality following hospitalization for electrical storm (ES), only limited data are available. The purpose of this study was to assess the incidence and predictors of early mortality following hospitalization in the intensive care unit (ICU) for ES in a large retrospective study. METHODS AND RESULTS: In this retrospective study, we included all patients who were hospitalized for ES from July 2015 to May 2020 in our tertiary centre. A total of 253 patients were included. The median age was 66 [56; 73], and 64% had ischemic cardiomyopathy. A total of 37% of patients presented hemodynamic instability requiring catecholamine at admission. A total of 17% of patients presented an acute reversible cause for ES. The one-year mortality was 34% (95% CI, 30-43%), mostly driven by heart failure (HF). The multivariable Cox's regression model identified age, left ventricular ejection fraction, right ventricle dysfunction, haemoglobin level as independent predictors of one-year mortality. The use of catecholamine at admission was identified as the only variable related to the initial management of ES associated with an increased 30-day mortality risk (HR: 7.95 (95%CI, 3.18-19.85). CONCLUSION: In patients admitted for ES in ICU, the one-year mortality remains high and mostly driven by HF. The use of catecholamine at admission is associated with a seven-fold risk for mortality within 30 days. In such patients, the potential use of VT ablation can be questioned and a careful action plan regarding invasive HF-related therapy could be considered.


Asunto(s)
Insuficiencia Cardíaca , Taquicardia Ventricular , Anciano , Catecolaminas , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia , Humanos , Incidencia , Unidades de Cuidados Intensivos , Estudios Retrospectivos , Volumen Sistólico , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/terapia , Fibrilación Ventricular , Función Ventricular Izquierda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA