1.
Am J Nephrol ; 53(6): 490-502, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35671711

RESUMEN

INTRODUCTION: Invasive bone biopsy to assess bone metabolism in patients with chronic kidney disease-mineral and bone disorder may be replaced by the noninvasive 18F-NaF PET/CT and biomarkers of bone metabolism. We aimed to compare parameters of bone turnover, mineralization, and volume assessed by bone biopsies with results derived from 18F-NaF PET/CT and biomarkers (bone-specific alkaline phosphatase, osteocalcin, fibroblast growth factor 23, and osteoprotegerin). METHODS: A cross-sectional study included 17 dialysis patients, and results from 18F-NaF PET/CT scans and the biomarkers were directly compared with the results of histomorphometric analyses of tetracycline double-labeled trans-iliac bone biopsies. RESULTS: Bone biopsies showed 40% high, 20% normal, and 40% low bone turnover. No biopsies had generalized abnormal mineralization, and the bone volume/total tissue volume was low in 80% and high in 7%. The pelvic skeletal plasma clearance (Ki) from 18F-NaF PET/CT correlated with bone turnover parameters obtained by bone biopsy (activation frequency: r = 0.82, p < 0.01; bone formation rate/bone surface: r = 0.81, p < 0.01), and Ki defined low turnover with high sensitivity (83%) and specificity (100%). CT-derived radiodensity correlated with bone volume, r = 0.82, p < 0.01. Of the biomarkers, only osteocalcin showed a correlation with turnover assessed by histomorphometry. CONCLUSION: In conclusion, 18F-NaF PET/CT may be applicable for noninvasive assessment of bone turnover and volume in CKD-MBD.


Asunto(s)
Trastorno Mineral y Óseo Asociado a la Enfermedad Renal Crónica , Insuficiencia Renal Crónica , Biomarcadores , Biopsia , Remodelación Ósea/fisiología , Trastorno Mineral y Óseo Asociado a la Enfermedad Renal Crónica/diagnóstico por imagen , Trastorno Mineral y Óseo Asociado a la Enfermedad Renal Crónica/etiología , Estudios Transversales , Radioisótopos de Flúor , Humanos , Minerales/metabolismo , Osteocalcina , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Sodio/metabolismo , Fluoruro de Sodio/metabolismo
2.
Clin Physiol Funct Imaging ; 41(6): 488-496, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34418886

RESUMEN

BACKGROUND: Accurate, precise and straightforward methods for measuring glomerular filtration rate (GFR) and/or renal plasma flow (RPF) are still in demand today. The time-consuming constant infusion technique (CIT) is the gold standard and preferred for research, whereas the simple, but less precise, single injection technique (SIT) is used in clinical settings. This study investigated the use of 99m Tc-DTPA and 99m Tc-MAG3 by CIT as a measure of renal function. We developed and evaluated a model to balance the primer dose and infusion rate in an attempt to obtain plasma steady state as quickly as possible. METHODS: 14 healthy subjects received 99m Tc-DTPA and 6 hypertensive patients received 99m Tc-MAG3 in a standardized protocol. All participants had an eGFR above 60 ml/min and none had fluid retention. An intravenous primer injection of the relevant tracer was followed by a sustained infusion over 4.5 h with the same radiopharmaceutical. Blood and urine samples were collected at fixed intervals. RESULTS: 99m Tc-DTPA clearance reached steady state after 210 min (plasma clearance 78 ± 18 ml/min, urine clearance 110 ± 28 ml/min), whereas 99m Tc-MAG3  clearance achieved steady state after 150 min (plasma clearance 212 ± 56 ml/min, urine clearance 233 ± 59 ml/min). CONCLUSION: Constant infusion technique with fixed primer and infusion rate using 99m Tc-MAG3 is feasible for research purposes. The longer time for reaching plasma steady state using 99m Tc-DTPA makes CIT with this tracer less optimal. If the primer/sustained balance can be optimized, for example using a priori SIT information, 99m Tc-DTPA as tracer for CIT may also be feasible.


Asunto(s)
Tecnecio Tc 99m Mertiatida , Pentetato de Tecnecio Tc 99m , Tasa de Filtración Glomerular , Humanos , Pruebas de Función Renal , Tecnecio