Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Acta Oncol ; 53(8): 1012-8, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24975370

RESUMEN

BACKGROUND: To compare five inverse treatment planning methods with the conventional manually optimized planning approach for brachytherapy of cervical cancer with respect to dosimetric parameters. MATERIAL AND METHODS: Eighteen cervical cancer patients treated with magnetic resonance imaging (MRI)-guided high dose rate (HDR) brachytherapy were included in this study. Six plans were created for each of the 4 HDR brachytherapy fractions for each patient: 1 manually optimized and 5 inversely planned. Three of these were based on inverse planning simulated annealing (IPSA) with and without extra constraints on maximum doses of the target volume, and different constraints on doses to the organs at risk (OARs). In addition there were two plans based on dose to target surface points. The resulting dose-volume histograms were analyzed and compared from the dosimetric point of view by quantifying specific dosimetric parameters, such as clinical target volume (CTV) D90, CTV D100, conformal index (COIN), and D2cm3 for rectum, bladder and the sigmoid colon. RESULTS: Manual optimization led to a mean target coverage of 78.3% compared to 87.5%, 91.7% and 82.5% with the three IPSA approaches (p < 0.001). Similar COIN values for manual and inverse optimization were found. The manual optimization led to better results with respect to the dose to the OARs expressed as D2cm3. Overall, the best results were obtained with manual optimization and IPSA plans with volumetric constraints including maximum doses to the target volume. CONCLUSIONS: Dosimetric evaluation of manual and inverse optimization approaches is indicating the potential of IPSA for brachytherapy of cervical cancer. IPSA with constraints of maximum doses to the target volume is closer related to manual optimization than plans with constraints only to minimum dose to the target volume and maximum doses to OARs. IPSA plans with proper constraints performed better than those based on dose to target surface points and manually optimized plans.


Asunto(s)
Braquiterapia/métodos , Imagen por Resonancia Magnética Intervencional , Órganos en Riesgo , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Guiada por Imagen/métodos , Neoplasias del Cuello Uterino/radioterapia , Colon Sigmoide , Fraccionamiento de la Dosis de Radiación , Femenino , Humanos , Dosificación Radioterapéutica , Recto , Factores de Tiempo , Vejiga Urinaria , Neoplasias del Cuello Uterino/patología
2.
Int J Radiat Oncol Biol Phys ; 106(5): 1052-1062, 2020 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-32007365

RESUMEN

PURPOSE: The aim of this study was to investigate the influence of brachytherapy technique and applicator type on target dose, isodose surface volumes, and organ-at-risk (OAR) dose. METHODS AND MATERIALS: Nine hundred two patients treated with tandem/ovoids (T&O) (n = 299) and tandem/ring (T&R) (n = 603) applicators from 16 EMBRACE centers were analyzed. Patients received external beam radiation therapy and magnetic resonance imaging guided brachytherapy with dose prescription according to departmental practice. Centers were divided into 4 groups, according to applicator/technique: Ovoids and ring centers treating mainly with the intracavitary (IC) technique and ovoids and ring centers treating routinely with the intracavitary/interstitial (IC/IS) technique. V85Gy EQD210, CTVHR D90% (EQD210), and bladder, rectum, sigmoid, and vaginal 5-mm lateral-point doses (EQD23) were evaluated among center groups. Differences between T&O and T&R were tested with multivariable analysis. RESULTS: For similar point A doses, mean CTVHR D90% was 3.3 Gy higher and V85Gy was 23% lower for ring-IC compared with ovoids-IC centers (at median target volumes). Mean bladder/rectum doses (D2cm3 and ICRU-point) were 3.2 to 7.7 Gy smaller and vaginal 5-mm lateral-point was 19.6 Gy higher for ring-IC centers. Routine use of IC/IS technique resulted in increased target dose, whereas V85Gy was stable (T&R) or decreased (T&O); reduced bladder and rectum D2cm3 and bladder ICRU-point by 3.5 to 5.0 Gy for ovoids centers; and similar OAR doses for ring centers. CTVHR D90% was 2.8 Gy higher, bladder D2cm3 4.3 Gy lower, rectovaginal ICRU-point 4.8 Gy lower, and vagina 5-mm lateral-point 22.4 Gy higher for ring-IC/IS versus ovoids-IC/IS centers. The P values were <.002 for all comparisons. Equivalently, significant differences were derived from the multivariable analysis. CONCLUSIONS: T&R-IC applicators have better target dose and dose conformity than T&O-IC in this representative patient cohort. IC applicators fail to cover large target volumes, whereas routine application of IC/IS improves target and OAR dose considerably. Patients treated with T&R show a more favorable therapeutic ratio when evaluating target, bladder/rectum doses, and V85Gy. A comprehensive view on technique/applicators should furthermore include practical considerations and clinical outcome.


Asunto(s)
Braquiterapia/instrumentación , Estudios Observacionales como Asunto , Neoplasias del Cuello Uterino/radioterapia , Braquiterapia/efectos adversos , Femenino , Humanos , Persona de Mediana Edad , Órganos en Riesgo/efectos de la radiación , Dosificación Radioterapéutica
3.
Oncol Rep ; 9(2): 397-403, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-11836616

RESUMEN

Different growth factors are supposed to be involved in evolution of breast cancer. Radiation therapy is used in treatment of breast cancer patients, and the possible relationships between the influence of growth factors on cells and their radiation sensitivity are therefore of interest. Cell growth and radiation sensitivity of the human oestrogen and progesterone receptor positive cell line T-47D were investigated following exposure to the growth factors IGF-1, TGF-alpha and TGF-beta. Experiments were done with standard medium and in growth factor defined medium. Changes in cell cycle distribution were investigated by flow cytometry. The cell growth was significantly decreased by removal of growth factors in the culture medium, an effect which partly could be reversed by supplementation of growth factors. The growth factors decreased the cellular doubling time in standard medium, but to a smaller extent than seen in growth factor defined medium. The radiation sensitivity and plating efficiency were slightly affected by growth factor defined versus standard growth conditions. Additional growth factor exposure was able to some extent to change the radiation sensitivity, mainly by effects due to changes in repair of sublethal damage. Only minor changes were seen in phase distribution of these cells. Cellular growth was dependent on presence of different growth factors, and changes in growth factor conditions greatly influenced the cellular doubling time in vitro. Corresponding changes in radiation sensitivity were minor for doses relevant for radiation therapy.


Asunto(s)
Neoplasias de la Mama/patología , Ciclo Celular/efectos de la radiación , División Celular/efectos de la radiación , Factor I del Crecimiento Similar a la Insulina/farmacología , Factor de Crecimiento Transformador alfa/farmacología , Factor de Crecimiento Transformador beta/farmacología , Células Tumorales Cultivadas/efectos de la radiación , Neoplasias de la Mama/metabolismo , Neoplasias de la Mama/radioterapia , Ciclo Celular/efectos de los fármacos , División Celular/efectos de los fármacos , Medios de Cultivo Condicionados , Relación Dosis-Respuesta a Droga , Femenino , Humanos , Dosis de Radiación , Tolerancia a Radiación