1.
J Vasc Interv Radiol ; 35(1): 113-121.e3, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37696432

RESUMEN

PURPOSE: To improve radiopacity of radiolucent absorbable poly-p-dioxanone (PPDO) inferior vena cava filters (IVCFs) and demostrate their effectiveness in clot-trapping ability. MATERIALS AND METHODS: Tungsten nanoparticles (WNPs) were incorporated along with polyhydroxybutyrate (PHB), polycaprolactone (PCL), and polyvinylpyrrolidone (PVP) polymers to increase the surface adsorption of WNPs. The physicochemical and in vitro and in vivo imaging properties of PPDO IVCFs with WNPs with single-polymer PHB (W-P) were compared with those of WNPs with polymer blends consisting of PHB, PCL, and PVP (W-PB). RESULTS: In vitro analyses using PPDO sutures showed enhanced radiopacity with either W-P or W-PB coating, without compromising the inherent physicomechanical properties of the PPDO sutures. W-P- and W-PB-coated IVCFs were deployed successfully into the inferior vena cava of pig models with monitoring by fluoroscopy. At the time of deployment, W-PB-coated IVCFs showed a 2-fold increase in radiopacity compared to W-P-coated IVCFs. Longitudinal monitoring of in vivo IVCFs over a 12-week period showed a drastic decrease in radiopacity at Week 3 for both filters. CONCLUSIONS: The results highlight the utility of nanoparticles (NPs) and polymers for enhancing radiopacity of medical devices. Different methods of incorporating NPs and polymers can still be explored to improve the effectiveness, safety, and quality of absorbable IVCFs.


Asunto(s)
Nanopartículas , Filtros de Vena Cava , Porcinos , Animales , Tungsteno , Polímeros , Vena Cava Inferior/diagnóstico por imagen , Vena Cava Inferior/cirugía , Remoción de Dispositivos
2.
J Vasc Interv Radiol ; 34(5): 782-789, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36539151

RESUMEN

PURPOSE: To evaluate the feasibility of using dual-energy computed tomography (CT) and theranostic cesium hydroxide (CsOH) for image guidance of thermochemical ablation (TCA) in a rabbit VX2 tumor model. MATERIALS AND METHODS: In vivo experiments were performed on New Zealand white rabbits, where VX2 tumor fragments (0.3 mL) were inoculated into the right and left flanks (n = 16 rabbits, 32 tumors). Catheters were placed in the approximate center of 1- to 2-cm diameter tumors under ultrasound guidance. TCA was delivered in 1 of 3 treatment groups: untreated control, 5-M TCA, or 10-M TCA. The TCA base reagent was doped with 250-mM CsOH. Dual-energy CT was performed before and after TCA. Cesium (CS)-specific images were postprocessed on the basis of previous phantom calibrations to determine Cs concentration. Line profiles were drawn through the ablation center. Twenty-four hours after TCA, subjects were euthanized, and the resulting damage was evaluated with histopathology. RESULTS: Cs was detected in 100% of treated tumors (n = 21). Line profiles indicated highest concentrations at the injection site and decreased concentrations at the tumor margins, with no Cs detected beyond the ablation zone. The maximum detected Cs concentration ranged from 14.39 to 137.33 mM. A dose-dependent trend in tissue necrosis was demonstrated between the 10-M TCA and 5-M TCA treatment groups (P = .0005) and untreated controls (P = .0089). CONCLUSIONS: Dual-energy CT provided image guidance for delivery, localization, and quantification of TCA in the rabbit VX2 model.


Asunto(s)
Neoplasias Hepáticas Experimentales , Tomografía Computarizada por Rayos X , Conejos , Animales , Tomografía Computarizada por Rayos X/métodos , Neoplasias Hepáticas Experimentales/cirugía , Cesio
3.
J Appl Clin Med Phys ; 22(5): 97-109, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33939253

RESUMEN

PURPOSE: The purpose of this work was to estimate and compare breast and lung doses of chest CT scans using organ-based tube current modulation (OBTCM) to those from conventional, attenuation-based automatic tube current modulation (ATCM) across a range of patient sizes. METHODS: Thirty-four patients (17 females, 17 males) who underwent clinically indicated CT chest/abdomen/pelvis (CAP) examinations employing OBTCM were collected from two multi-detector row CT scanners. Patient size metric was assessed as water equivalent diameter (Dw ) taken at the center of the scan volume. Breast and lung tissues were segmented from patient image data to create voxelized models for use in a Monte Carlo transport code. The OBTCM schemes for the chest portion were extracted from the raw projection data. ATCM schemes were estimated using a recently developed method. Breast and lung doses for each TCM scenario were estimated for each patient model. CTDIvol -normalized breast (nDbreast ) and lung (nDlung ) doses were subsequently calculated. The differences between OBTCM and ATCM normalized organ dose estimates were tested using linear regression models that included CT scanner and Dw as covariates. RESULTS: Mean dose reduction from OBTCM in nDbreast was significant after adjusting for the scanner models and patient size (P = 0.047). When pooled with females and male patient, mean dose reduction from OBTCM in nDlung was observed to be trending after adjusting for the scanner model and patient size (P = 0.085). CONCLUSIONS: One specific manufacturer's OBTCM was analyzed. OBTCM was observed to significantly decrease normalized breast relative to a modeled version of that same manufacturer's ATCM scheme. However, significant dose savings were not observed in lung dose over all. Results from this study support the use of OBTCM chest protocols for females only.


Asunto(s)
Mama , Tomografía Computarizada por Rayos X , Mama/diagnóstico por imagen , Femenino , Humanos , Pulmón/diagnóstico por imagen , Masculino , Método de Montecarlo , Fantasmas de Imagen , Dosis de Radiación
4.
Int J Hyperthermia ; 37(1): 356-365, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32308071

RESUMEN

Background: Thermoembolization presents a unique treatment alternative for patients diagnosed with hepatocellular carcinoma. The approach delivers a reagent that undergoes an exothermic chemical reaction and combines the benefits of embolic as well as thermal- and chemical-ablative therapy modalities. The target tissue and vascular bed are subjected to simultaneous hyperthermia, ischemia, and chemical denaturation in a single procedure. To guide optimal delivery, we developed a mathematical model for understanding the competing diffusive and convective effects observed in thermoembolization delivery protocols.Methods: A mixture theory formulation was used to mathematically model thermoembolization as chemically reacting transport of an electrophile, dichloroacetyl chloride (DCACl), within porous living tissue. Mass and energy transport of each relevant constituent are considered. Specifically, DCACl is injected into the vessels and exothermically reacts with water in the blood or tissue to form dichloroacetic acid and hydrochloric acid. Neutralization reactions are assumed instantaneous in this approach. We validated the mathematical model predictions of temperature using MR thermometry of the thermoembolization procedure performed in ex vivo kidney.Results: Mathematical modeling predictions of tissue death were highly dependent on the vascular geometry, injection pressure, and intrinsic amount of exothermic energy released from the chemical species, and were able to recapitulate the temperature distributions observed in MR thermometry.Conclusion: These efforts present a first step toward formalizing a mathematical model for thermoembolization and are promising for providing insight for delivery protocol optimization. While our approach captured the observed experimental temperature measurements, larger-scale experimental validation is needed to prioritize additional model complexity and fidelity.


Asunto(s)
Embolización Terapéutica/métodos , Modelos Teóricos , Humanos
5.
Radiology ; 292(2): 414-419, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31237496

RESUMEN

Background Assessments of the quantitative limitations among the six commercially available dual-energy (DE) CT acquisition schemes used by major CT manufacturers could aid researchers looking to use iodine quantification as an imaging biomarker. Purpose To determine the limits of detection and quantification of DE CT in phantoms by comparing rapid peak kilovoltage switching, dual-source, split-filter, and dual-layer detector systems in six different scanners. Materials and Methods Seven 50-mL iohexol solutions were used, with concentrations of 0.03-2.0 mg iodine per milliliter. The solutions and water sample were scanned five times each in two phantoms (small, 20-cm diameter; large, 30 × 40-cm diameter) with six DE CT systems and a total of 10 peak kilovoltage settings or combinations. Iodine maps were created, and the mean iodine signal in each sample was recorded. The limit of blank (LOB) was defined as the upper limit of the 95% confidence interval of the water sample. The limit of detection (LOD) was defined as the concentration with a 95% chance of having a signal above the LOB. The limit of quantification (LOQ) was defined as the lowest concentration where the coefficient of variation was less than 20%. Results The LOD range was 0.021-0.26 mg/mL in the small phantom and 0.026-0.55 mg/mL in the large phantom. The LOQ range was 0.07-0.50 mg/mL in the small phantom and 0.20-1.0 mg/mL in the large phantom. The dual-source and rapid peak kilovoltage switching systems had the lowest LODs, and the dual-layer detector systems had the highest LODs. Conclusion The iodine limit of detection using dual-energy CT systems varied with scanner and phantom size, but all systems depicted iodine in the small and large phantoms at or below 0.3 and 0.5 mg/mL, respectively, and enabled quantification at concentrations of 0.5 and 1.0 mg/mL, respectively. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Hindman in this issue.


Asunto(s)
Medios de Contraste , Yodo , Intensificación de Imagen Radiográfica/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen , Reproducibilidad de los Resultados
6.
AJR Am J Roentgenol ; 213(3): W143-W144, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31166756

RESUMEN

OBJECTIVE. The objective of this video article is to discuss the use of the scapular osteocutaneous free flap in reconstructive procedures. We attempt to discuss normal and variant vascular anatomy, image acquisition via CT angiography, and image interpretation as well as computer-assisted design and manufacturing. CONCLUSION. The scapular osteocutaneous free flap is commonly used for maxillary and mandibular reconstructive surgery. The complex vasculature supplying the scapular region allows flap versatility. There are anatomic variations in the origin of the circumflex scapular and angular arteries. Our method of performing and reporting CT angiography for patients scheduled to undergo scapular osteocutaneous free flap procedures provides a reliable and reproducible means of communicating important elements of vasculature to surgeons. This in turn can facilitate the manufacturing of custom scapular cutting guides and improve surgical outcomes.


Asunto(s)
Trasplante Óseo/métodos , Angiografía por Tomografía Computarizada , Colgajos Tisulares Libres/irrigación sanguínea , Colgajos Tisulares Libres/trasplante , Procedimientos de Cirugía Plástica , Escápula/irrigación sanguínea , Escápula/diagnóstico por imagen , Escápula/trasplante , Humanos
7.
Int J Hyperthermia ; 36(1): 730-738, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31362538

RESUMEN

Purpose: MR temperature imaging (MRTI) was employed for visualizing the spatiotemporal evolution of the exotherm of thermoembolization, an investigative transarterial treatment for solid tumors. Materials and methods: Five explanted kidneys were injected with thermoembolic solutions, and monitored by MRTI. In three nonselective experiments, 5 ml of 4 mol/l dichloroacetyl chloride (DCA-Cl) solution in a hydrocarbon vehicle was injected via the main renal artery. For two of these three, MRTI temperature data were compared to fiber optic thermal probes. Another two kidneys received selective injections, treating only portions of the kidneys with 1 ml of 2 mol/l DCA-Cl. MRTI data were acquired and compared to changes in pre- and post-injection CT. Specimens were bisected and photographed for gross pathology 24 h post-procedure. Results: MRTI temperature estimates were within ±1 °C of the probes. In experiments without probes, MRTI measured increases of 30 °C. Some regions had not reached peak temperature by the end of the >18 min acquisition. MRTI indicated the initial heating occurred in the renal cortex, gradually spreading more proximally toward the main renal artery. Gross pathology showed the nonselective injection denatured the entire kidney whereas in the selective injections, only the treated territory was coagulated. Conclusion: The spatiotemporal evolution of thermoembolization was visualized for the first time using noninvasive MRTI, providing unique insight into the thermodynamics of thermoembolization. Précis Thermoembolization is being investigated as a novel transarterial treatment. In order to begin to characterize delivery of this novel treatment modality and aid translation from the laboratory to patients, we employ MR temperature imaging to visualize the spatiotemporal distribution of temperature from thermoembolization in ex vivo tissue.


Asunto(s)
Embolización Terapéutica , Imagen por Resonancia Magnética , Termografía , Animales , Riñón/diagnóstico por imagen , Arteria Renal/diagnóstico por imagen , Porcinos , Temperatura
8.
J Appl Clin Med Phys ; 20(11): 199-205, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31609076

RESUMEN

PURPOSE: Routine quality assurance (QA) testing to identify malfunctions in medical imaging devices is a standard practice and plays an important role in meeting quality standards. However, current daily computed tomography (CT) QA techniques have proven to be inadequate for the detection of subtle artifacts on scans. Therefore, we investigated the ability of a radiomics phantom to detect subtle artifacts not detected in conventional daily QA. METHODS: An updated credence cartridge radiomics phantom was used in this study, with a focus on two of the cartridges (rubber and cork) in the phantom. The phantom was scanned using a Siemens Definition Flash CT scanner, which was reported to produce a subtle line pattern artifact. Images were then imported into the IBEX software program, and 49 features were extracted from the two cartridges using four different preprocessing techniques. Each feature was then compared with features for the same scanner several months previously and with features from controlled CT scans obtained using 100 scanners. RESULTS: Of 196 total features for the test scanner, 79 (40%) from the rubber cartridge and 70 (36%) from the cork cartridge were three or more standard deviations away from the mean of the controlled scan population data. Feature values for the artifact-producing scanner were closer to the population mean when features were preprocessed with Butterworth smoothing. The feature most sensitive to the artifact was co-occurrence matrix maximum probability. The deviation from the mean for this feature was more than seven times greater when the scanner was malfunctioning (7.56 versus 1.01). CONCLUSIONS: Radiomics features extracted from a texture phantom were able to identify an artifact-producing scanner as an outlier among 100 CT scanners. This preliminary analysis demonstrated the potential of radiomics in CT QA to identify subtle artifacts not detected using the currently employed daily QA techniques.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Linfoma/diagnóstico por imagen , Fantasmas de Imagen , Garantía de la Calidad de Atención de Salud/normas , Tomógrafos Computarizados por Rayos X/normas , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Humanos , Tomografía Computarizada por Rayos X/instrumentación
9.
Med Phys ; 50(12): 7879-7890, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37409792

RESUMEN

BACKGROUND: Thermochemical ablation (TCA) is a minimally invasive therapy under development for hepatocellular carcinoma. TCA simultaneously delivers an acid (acetic acid, AcOH) and base (sodium hydroxide, NaOH) directly into the tumor, where the acid/base chemical reaction produces an exotherm that induces local ablation. However, AcOH and NaOH are not radiopaque, making monitoring TCA delivery difficult. PURPOSE: We address the issue of image guidance for TCA by utilizing cesium hydroxide (CsOH) as a novel theranostic component of TCA that is detectable and quantifiable with dual-energy CT (DECT). MATERIALS AND METHODS: To quantify the minimum concentration of CsOH that can be positively identified by DECT, the limit of detection (LOD) was established in an elliptical phantom (Multi-Energy CT Quality Assurance Phantom, Kyoto Kagaku, Kyoto, Japan) with two DECT technologies: a dual-source system (SOMATOM Force, Siemens Healthineers, Forchheim, Germany) and a split-filter, single-source system (SOMATOM Edge, Siemens Healthineers). The dual-energy ratio (DER) and LOD of CsOH were determined for each system. Cesium concentration quantification accuracy was evaluated in a gelatin phantom before quantitative mapping was performed in ex vivo models. RESULTS: On the dual-source system, the DER and LOD were 2.94 and 1.36-mM CsOH, respectively. For the split-filter system, the DER and LOD were 1.41- and 6.11-mM CsOH, respectively. The signal on cesium maps in phantoms tracked linearly with concentration (R2  = 0.99) on both systems with an RMSE of 2.56 and 6.72 on the dual-source and split-filter system, respectively. In ex vivo models, CsOH was detected following delivery of TCA at all concentrations. CONCLUSIONS: DECT can be used to detect and quantify the concentration of cesium in phantom and ex vivo tissue models. When incorporated in TCA, CsOH performs as a theranostic agent for quantitative DECT image-guidance.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Medios de Contraste , Hidróxido de Sodio , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen
10.
bioRxiv ; 2023 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-36798362

RESUMEN

The use of absorbable inferior vena cava filters (IVCFs) constructed with poly-p-dioxanone (PPDO) eliminates risks and complications associated with the use of retrievable metallic filters. Radiopacity of radiolucent PPDO IVCFs can be improved with the incorporation of nanoparticles (NPs) made of high-atomic number materials such as gold and bismuth. In this study, we focused on incorporating tungsten NPs (WNPs), along with polyhydroxybutyrate (PHB), polycaprolactone (PCL), and polyvinylpyrrolidone (PVP) polymers to increase the surface adsorption of the WNPs. We compared the imaging properties of WNPs with single-polymer PHB (W-P) and WNPs with polymer blends consisting of PHB, PCL, and PVP (W-PB). Our in vitro analyses using PPDO sutures showed enhanced radiopacity with either W-P or W-PB coating, without compromising the inherent physico-mechanical properties of the PPDO sutures. We observed a more sustained release of WNPs from W-PB-coated sutures than W-P-coated sutures. We successfully deployed W-P- and W-PB-coated IVCFs into the inferior vena cava of pig models, with monitoring by fluoroscopy. At the time of deployment, W-PB-coated IVCFs showed a 2-fold increase in radiopacity compared to W-P-coated IVCFs. Longitudinal monitoring of in vivo IVCFs over a 12-week period showed a drastic decrease in radiopacity at week 3 for both filters. Results of this study highlight the utility of NPs and polymers for enhancing radiopacity of medical devices; however, different methods of incorporating NPs and polymers can still be explored to improve the efficacy, safety, and quality of absorbable IVCFs.

11.
Materials (Basel) ; 15(3)2022 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-35161128

RESUMEN

Existing natural latex radiation-attenuating gloves (RAGs) contain a high loading of radiation attenuation filler that reduces their mechanical properties to below Food and Drug Administration (FDA) medical glove requirements. RAGs are commonly formulated using Hevea natural rubber latex and lead-based fillers. The former can cause life-threatening allergic responses and the latter are known for their toxicity. In this work, a new lead-free RAG formulation based on circumallergenic guayule natural rubber latex (GNRL) and non-toxic radiation attenuation filler bismuth trioxide (Bi2O3) was developed. GNRL films with Bi2O3 loadings ranging from 0 to 300 PHR at different thicknesses were prepared. Radiation attenuation efficiencies (AE) at 60, 80, 100, and 120 kVp were determined and attenuation isocontour curves predicted film thickness and Bi2O3 loading required to meet or exceed the radiation attenuation requirements of ASTM D7866 and commercial RAGs. Optimal curing conditions for GNRL/Bi2O3 films with 150 PHR Bi2O3 were investigated by varying curing temperatures and time from 87 °C to 96 °C and 65 min to 90 min, respectively. In general, as the loading of the filler increased, the density of the films increased while the thickness decreased. GNRL/Bi2O3 films with 150 PHR Bi2O3 and 0.27 mm provided 5% more AE than RAG market average attenuation at the same thickness. The films with 150 PHR Bi2O3 cured under near-optimal conditions (90 °C/85 min, and 87 °C/65 min) met both the radiation attenuation standard (ASTM D7866) and the natural latex surgeon and examination glove standards (ASTM D3577 and D3578, respectively). Thus, gloves made using our formulations and protocols demonstrated potential to meet and surpass medical natural latex glove standards, offer a single product for both infection control and radiation protection instead of double-gloving, provide a greater degree of comfort to the user, and simultaneously reduce contact reactions and eliminate potential latex allergic reaction.

12.
Br J Radiol ; 95(1129): 20210699, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34538091

RESUMEN

Dual-energy CT (DECT) imaging is a technique that extends the capabilities of CT beyond that of established densitometric evaluations. CT pulmonary angiography (CTPA) performed with dual-energy technique benefits from both the availability of low kVp CT data and also the concurrent ability to quantify iodine enhancement in the lung parenchyma. Parenchymal enhancement, presented as pulmonary perfused blood volume maps, may be considered as a surrogate of pulmonary perfusion. These distinct capabilities have led to new opportunities in the evaluation of pulmonary vascular diseases. Dual-energy CTPA offers the potential for improvements in pulmonary emboli detection, diagnostic confidence, and most notably severity stratification. Furthermore, the appreciated insights of pulmonary vascular physiology conferred by DECT have resulted in increased use for the assessment of pulmonary hypertension, with particular utility in the subset of patients with chronic thromboembolic pulmonary hypertension. With the increasing availability of dual energy-capable CT systems, dual energy CTPA is becoming a standard-of-care protocol for CTPA acquisition in acute PE. Furthermore, qualitative and quantitative pulmonary vascular DECT data heralds promise for the technique as a "one-stop shop" for diagnosis and surveillance assessment in patients with pulmonary hypertension. This review explores the current application, clinical value, and limitations of DECT imaging in acute and chronic pulmonary vascular conditions. It should be noted that certain manufacturers and investigators prefer alternative terms, such as spectral or multi-energy CT imaging. In this review, the term dual energy is utilised, although readers can consider these terms synonymous for purposes of the principles explained.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Enfermedades Pulmonares/diagnóstico por imagen , Enfermedades Vasculares/diagnóstico por imagen , Angiografía por Tomografía Computarizada/instrumentación , Humanos , Hipertensión Pulmonar/diagnóstico por imagen , Circulación Pulmonar , Embolia Pulmonar/diagnóstico por imagen
13.
ACS Biomater Sci Eng ; 8(4): 1676-1685, 2022 04 11.
Artículo en Inglés | MEDLINE | ID: mdl-35343679

RESUMEN

Inferior vena cava filters (IVCFs) constructed with poly-p-dioxanone (PPDO) are promising alternatives to metallic filters and their associated risks and complications. Incorporating high-Z nanoparticles (NPs) improves PPDO IVCFs' radiopacity without adversely affecting their safety or performance. However, increased radiopacity from these studies are insufficient for filter visualization during fluoroscopy-guided PPDO IVCF deployment. This study focuses on the use of bismuth nanoparticles (BiNPs) as radiopacifiers to render sufficient signal intensity for the fluoroscopy-guided deployment and long-term CT monitoring of PPDO IVCFs. The use of polyhydroxybutyate (PHB) as an additional layer to increase the surface adsorption of NPs resulted in a 2-fold increase in BiNP coating (BiNP-PPDO IVCFs, 3.8%; BiNP-PPDO + PHB IVCFs, 6.2%), enabling complete filter visualization during fluoroscopy-guided IVCF deployment and, 1 week later, clot deployment. The biocompatibility, clot-trapping efficacy, and mechanical strength of the control PPDO (load-at-break, 6.23 ± 0.13 kg), BiNP-PPDO (6.10 ± 0.09 kg), and BiNP-PPDO + PHB (6.15 ± 0.13 kg) IVCFs did not differ significantly over a 12-week monitoring period in pigs. These results indicate that BiNP-PPDO + PHB can increase the radiodensity of a novel absorbable IVCF without compromising device strength. Visualizing the device under conventional radiographic imaging is key to allow safe and effective clinical translation of the device.


Asunto(s)
Nanopartículas , Filtros de Vena Cava , Animales , Bismuto , Fluoroscopía , Nanopartículas/uso terapéutico , Porcinos , Tomografía Computarizada por Rayos X
14.
Med Phys ; 48(2): 640-647, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33283284

RESUMEN

PURPOSE: Assessment of image quality directly in clinical image data is an important quality control objective as phantom-based testing does not fully represent image quality across patient variation. Computer algorithms for automatically measuring noise in clinical computed tomography (CT) images have been introduced, but the accuracy of these algorithms is unclear. This work benchmarks the accuracy of the global noise (GN) algorithm for automatic noise measurement in contrast-enhanced abdomen CT exams in comparison to precise reference noise measurements. The GN algorithm was further optimized compared to the previous report in the literature. METHODS: Reference values of noise were established in a public image dataset of 82 contrast-enhanced abdomen CT exams. The reference noise values were obtained by manual regions-of-interest measurements of pixel standard deviation in the liver parenchyma according to an instruction protocol. Noise measurements taken by six observers were averaged together to improve reference noise statistical precision. The GN algorithm was used to automatically measure noise in each image set. The accuracy of the GN algorithm was determined in terms of RMS error compared to reference noise. The GN algorithm was optimized by conducting 1000 trials with random algorithm parameter values. The trial with the lowest RMS error was used to select optimum algorithm parameters. RESULTS: The range of noise across CT image sets was 8.8-28.8 HU. Reference noise measurements were made with a precision of ±0.78 HU (95% confidence interval). The RMS error of automatic noise measurement was 0.93 HU (0.77-1.19 HU 95% confidence interval). The automatic noise measurements were equally accurate across image sets of varying noise magnitude. Optimum GN algorithm parameter values were: a kernel size of 7 pixels, and soft tissue lower and upper thresholds of 0 and 170 HU, respectively. CONCLUSIONS: The performance of automatic noise measurement was benchmarked in a large clinical CT dataset. The study provides a framework for thorough validation of automatic clinical image quality measurement methods. The GN algorithm was optimized and validated for automatic measurement of soft-tissue noise in abdomen CT exams.


Asunto(s)
Benchmarking , Procesamiento de Imagen Asistido por Computador , Algoritmos , Humanos , Fantasmas de Imagen , Tomografía Computarizada por Rayos X
15.
Med Phys ; 48(1): 300-312, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33216978

RESUMEN

PURPOSE: Material differentiation has been made possible using dual-energy computed tomography (DECT), in which the unique, energy-dependent attenuating characteristics of materials can provide new diagnostic information. One promising application is the clinical integration of biodegradable polymers as temporary implantable medical devices impregnated with high-atomic number (high-Z) materials. The purpose of this study was to explore the incorporation of high atomic number (high-Z) contrast materials in a bioresorbable inferior vena cava filter for advanced CT-based monitoring of its location and differentiating from surrounding materials. MATERIALS AND METHODS: Imaging optimization and calibration studies were performed using a body phantom. The dual-energy CT (DECT) ratios for iron, zirconium, barium, gadolinium, ytterbium, tantalum, tungsten, gold, and bismuth were generated for peak kilovoltage combinations of 80/150Sn, 90/150Sn, and 100/150Sn kVp in dual-source CT via linear regression of the CT numbers at low and high energies. A secondary calibration of the material map to the nominal material concentration was generated to correct for use of materials other than iodine. CT number was calibrated to the material concentration based on single-energy CT (SECT) with additional filtration (150Sn kVp). These quantification methods were applied to monitoring of biodegradable inferior vena cava filters (IVCFs) made of braided poly(p-dioxanone) sutures infused with ultrasmall bismuth nanoparticles (BiNPs) implanted in an adult domestic pig. RESULTS: Qualitative material differentiation was optimal for high-Z (>73) contrast agents in DECT. However, quantification became nonlinear and inaccurate as the K-edge of the material increased. Using the high-energy (150Sn kVp) data component as a SECT scan, the linearity of quantification curves was maintained with lower limits of detection than with DECT. Among the materials tested, bismuth had optimal differentiation from iodine in DECT while maintaining increased contrast in high-energy SECT for quantification (11.5% error). Coating the IVCF with BiNPs resulted in markedly greater radiopacity (maximum CT number, 2028 HU) than that of an uncoated IVCF (maximum CT number, 127 HU). Using DECT imaging and processing, the BiNP-IVCF could be clearly differentiated from iodine contrast injected into the inferior vena cava of the pig. CONCLUSIONS: These findings may improve widespread integration of medical devices incorporated with high-Z materials into the clinic, where technical success, possible complications, and device integrity can be assessed intraoperatively and postoperatively via DECT imaging.


Asunto(s)
Yodo , Nanopartículas , Animales , Calibración , Fantasmas de Imagen , Porcinos , Tomografía Computarizada por Rayos X
16.
Med Phys ; 47(7): e881-e912, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32215937

RESUMEN

In x-ray computed tomography (CT), materials with different elemental compositions can have identical CT number values, depending on the mass density of each material and the energy of the detected x-ray beam. Differentiating and classifying different tissue types and contrast agents can thus be extremely challenging. In multienergy CT, one or more additional attenuation measurements are obtained at a second, third or more energy. This allows the differentiation of at least two materials. Commercial dual-energy CT systems (only two energy measurements) are now available either using sequential acquisitions of low- and high-tube potential scans, fast tube-potential switching, beam filtration combined with spiral scanning, dual-source, or dual-layer detector approaches. The use of energy-resolving, photon-counting detectors is now being evaluated on research systems. Irrespective of the technological approach to data acquisition, all commercial multienergy CT systems circa 2020 provide dual-energy data. Material decomposition algorithms are then used to identify specific materials according to their effective atomic number and/or to quantitate mass density. These algorithms are applied to either projection or image data. Since 2006, a number of clinical applications have been developed for commercial release, including those that automatically (a) remove the calcium signal from bony anatomy and/or calcified plaque; (b) create iodine concentration maps from contrast-enhanced CT data and/or quantify absolute iodine concentration; (c) create virtual non-contrast-enhanced images from contrast-enhanced scans; (d) identify perfused blood volume in lung parenchyma or the myocardium; and (e) characterize materials according to their elemental compositions, which can allow in vivo differentiation between uric acid and non-uric acid urinary stones or uric acid (gout) or non-uric acid (calcium pyrophosphate) deposits in articulating joints and surrounding tissues. In this report, the underlying physical principles of multienergy CT are reviewed and each of the current technical approaches are described. In addition, current and evolving clinical applications are introduced. Finally, the impact of multienergy CT technology on patient radiation dose is summarized.


Asunto(s)
Yodo , Tomografía Computarizada por Rayos X , Algoritmos , Humanos , Fantasmas de Imagen , Fotones , Rayos X
17.
Med Phys ; 47(8): 3752-3771, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32453879

RESUMEN

Computed tomography (CT) technology has rapidly evolved since its introduction in the 1970s. It is a highly important diagnostic tool for clinicians as demonstrated by the significant increase in utilization over several decades. However, much of the effort to develop and advance CT applications has been focused on improving visual sensitivity and reducing radiation dose. In comparison to these areas, improvements in quantitative CT have lagged behind. While this could be a consequence of the technological limitations of conventional CT, advanced dual-energy CT (DECT) and photon-counting detector CT (PCD-CT) offer new opportunities for quantitation. Routine use of DECT is becoming more widely available and PCD-CT is rapidly developing. This review covers efforts to address an unmet need for improved quantitative imaging to better characterize disease, identify biomarkers, and evaluate therapeutic response, with an emphasis on multi-energy CT applications. The review will primarily discuss applications that have utilized quantitative metrics using both conventional and DECT, such as bone mineral density measurement, evaluation of renal lesions, and diagnosis of fatty liver disease. Other topics that will be discussed include efforts to improve quantitative CT volumetry and radiomics. Finally, we will address the use of quantitative CT to enhance image-guided techniques for surgery, radiotherapy and interventions and provide unique opportunities for development of new contrast agents.


Asunto(s)
Fotones , Tomografía Computarizada por Rayos X , Tomografía
18.
Abdom Radiol (NY) ; 45(4): 1100-1109, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32052130

RESUMEN

PURPOSE: To evaluate the quantitative attenuation and reliability of virtual non-contrast (VNC) images of the abdomen acquired from multiphasic scans with a dual-energy computed tomography (DECT) system and compare it with that of true non-enhanced images (TNC) on second- (Flash) and third- (Force) generation DECT scanners. METHODS: This retrospective study was approved by the institutional review board and included 123 patients with pancreatic cancer who had undergone routine clinical multiphasic DECT examinations at our institution using Flash and Force scanners between March and August 2017. VNC images of the abdomen were reconstructed from late arterial phase images. For every patient, regions-of-interest were defined in the aorta, fluid-containing structures (gallbladder, pleural effusion, and renal cysts > 10 mm), paravertebral muscles, subcutaneous fat, spleen, pancreas, renal cortex, and liver (eight locations) on TNC and VNC images. The mean attenuation of VNC was compared with TNC by organ for each CT scanner using an equivalence test and the Bland-Altman plot. The mean attenuations for TNC or VNC were compared between the Force and Flash CT scanners using a two-sample t test. RESULTS: The VNC attenuation of organs on the Force scanner was lower than was that on the Flash, and the mean attenuation difference in different organs on the Force was closer to 0. The estimated means of TNC and VNC were equivalent for an equivalence margin of 10 on the Force scanner. CONCLUSION: VNC images in DECT are a promising alternative to TNC images. In clinical scenarios in which non-enhanced CT images are required but are not available for accurate diagnosis, VNC images can potentially serve as an alternative to TNC images without the radiation exposure risks.


Asunto(s)
Abdomen/diagnóstico por imagen , Neoplasias Pancreáticas/diagnóstico por imagen , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador , Reproducibilidad de los Resultados , Estudios Retrospectivos
19.
Biomater Sci ; 8(14): 3966-3978, 2020 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-32558854

RESUMEN

Absorbable inferior vena cava filters (IVCFs) offer a promising alternative to metallic retrievable filters in providing protection against pulmonary embolism (PE) for patients contraindicated for anticoagulant therapy. However, because absorbable filters are not radiopaque, monitoring of the filter using conventional X-ray imaging modalities (e.g. plain film radiographs, computed tomography [CT] and fluoroscopy) during deployment and follow-up is not possible and represents a potential obstacle to widespread clinical integration of the device. Here, we demonstrate that gold nanoparticles (AuNPs) infused into biodegradable filters made up of poly-p-dioxanone (PPDO) may improve device radiopacity without untoward effects on device efficacy and safety, as assessed in swine models for 12 weeks. The absorbable AuNP-infused filters demonstrated significantly improved visualization using CT without affecting tensile strength, in vitro degradation, in vivo resorption, or thrombus-capturing efficacy, as compared to similar non-AuNPs infused resorbable IVCFs. This study presents a significant advancement to the development of imaging enhancers for absorbable IVCFs.


Asunto(s)
Nanopartículas del Metal , Embolia Pulmonar , Filtros de Vena Cava , Animales , Oro , Humanos , Porcinos , Resistencia a la Tracción
20.
Med Phys ; 46(8): 3442-3450, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31116445

RESUMEN

PURPOSE: Grid artifacts occur in digital mammography when synchronization between the grid assembly and generator is not achieved, including when malfunctions occur in the grid assembly or generator subsystems. Such artifacts are not explicitly monitored or evaluated by existing mammography quality control programs. In this study, we developed an automated method for quantifying the presence of grid artifacts in two-dimensional (2D) digital mammography images and assessed its utility as a supplement to existing quality control programs. METHODS: Four digital mammography systems (Hologic Dimensions 3D 5000) were configured to automatically transfer 2D images to a server where the strength of the grid pattern, γmax , was quantified using a template-matching algorithm and stored in amySQL database. This analysis was performed on both American College of Radiology (ACR) phantom and clinical images. Changes in γmax were compared with image quality and service records to establish preliminary action limits for physicist intervention for each type of image. These action limits were applied around selected service events to evaluate their clinical utility. RESULTS: All systems exhibited a gradual increase in γmax in ACR phantom images prior to having identical major components of the generator subsystem replaced, despite the absence of visible gridlines in the images. Retrospective analysis of phantom images suggested that physicists should consider AEC testing when γ max exceeds 0.050 and that clinical image quality may be affected when γ max exceeds 0.060. Eighteen of 19 visible grid artifacts were identified using a threshold γ max value of 0.065 in clinical images. Warning limits that indicate abnormal operation before visible degradation in image quality were also established. These warning limits were 0.046 and 0.041 for the 24 × 29 cm and 18 × 24 cm paddles, respectively. Specific malfunctions in the generator and grid subsystems can be detected by applying these limits. CONCLUSIONS: Automated monitoring of γ max provides useful information about the status of digital mammography units without affecting clinical operations. When used with appropriate action limits, this type of monitoring can help physicists identify specific equipment malfunctions before they would be detected by other quality control tests and before they affect clinical images.


Asunto(s)
Artefactos , Mamografía , Algoritmos , Automatización , Humanos , Fantasmas de Imagen , Control de Calidad