Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38519041

RESUMEN

PURPOSE: Ductus venosus (DV) Doppler velocimetry reflects fetal cardiac function. Gestational diabetes mellitus (GDM) is assumed to impair cardiac function due to fetal hyperglycemia. The purpose of this study was to assess the ability of DV Doppler to predict an adverse perinatal outcome (APO) in term pregnancies with GDM. METHODS: This is a retrospective cohort study including GDM pregnancies of singleton, non-anomalous fetuses without any signs of placental dysfunction. All GDM women who primarily had a vaginal delivery attempt and in which DV Doppler was examined from 37+0 weeks on were included. Receiver operating characteristic curve (ROC) analyses were performed to assess the predictive value of DV pulsatility index (DV-PI) regarding a composite APO (CAPO). Furthermore, a subgroup analysis was performed regarding the presence of a large-for-gestational-age (LGA) newborn. RESULTS: A total of n=89 cases were included. Overall, CAPO occurred in 26 out of 89 cases (29.2%). All DV Doppler examinations showed a positive A wave. DV-PI was>95th percentile in 8 out of 89 cases (9%). Overall, ROC analysis showed no significant association of DV-PI with CAPO (AUC=0.523, p=0.735). However, regarding individual APO parameters, ROC analysis showed a significant association of DV-PI with 5th-min AGPAR (AUC=0.960, p=0.027), which was not confirmed after exclusion of LGA cases. CONCLUSION: In GDM pregnancies at term, DV Doppler sonography seems to have no benefit for APO prediction.

2.
Arch Gynecol Obstet ; 308(3): 849-855, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36038657

RESUMEN

PURPOSE: The cerebroplacental ratio (CPR) is associated with adverse perinatal outcome (APO) in low-risk pregnancies near term. A Doppler parameter, which also includes information from the uterine vessels could potentially improve detection of subclinical placental dysfunction. The aim of this study is to investigate the performance of cerebro-placental-uterine ratio (CPUR) related to APO prediction in low-risk term pregnancies in > 40 + 0 weeks. METHODS: This is a retrospective cohort study. All low-risk pregnancies in which feto-maternal Doppler was examined from 40 + 0 weeks and an appropriate for gestational age fetus was present were included. ROC (receiver operating characteristic curves) analyses were performed to assess the predictive value of CPUR. The presence of at least one of the following outcome parameters was defined as composite APO (CAPO): operative delivery (OD) due to intrapartum fetal compromise (IFC), admission to the neonatal intensive care unit, umbilical cord arterial pH ≤ 7.15, 5 min APGAR ≤ 7. RESULTS: A total of n = 114 cases were included. Mean gestational age at examination and delivery were 40 + 3 weeks and 40 + 6 weeks, respectively. Overall, CAPO occurred in 38 of 114 cases (33.3%). ROC analyses showed a significant association of CPUR (AUC = 0.67, p = 0.004) and CPR (AUC = 0.68, p = 0.002) with CAPO. Additionally, CPUR (AUC = 0.64, p = 0.040) showed a predictive value for OD due to IFC. CONCLUSION: The CPUR in > 40 + 0 weeks showed a predictive value for CAPO and OD due to IFC in low-risk pregnancies. However, the extent to which CPUR can be used to optimize delivery management warrants further investigations in prospective interventional studies.


Asunto(s)
Placenta , Embarazo de Alto Riesgo , Recién Nacido , Embarazo , Femenino , Humanos , Placenta/diagnóstico por imagen , Estudios Prospectivos , Estudios Retrospectivos , Ultrasonografía Doppler , Ultrasonografía Prenatal , Arteria Cerebral Media/diagnóstico por imagen , Arterias Umbilicales/diagnóstico por imagen , Resultado del Embarazo , Flujo Pulsátil , Valor Predictivo de las Pruebas
3.
Ultraschall Med ; 44(6): 623-630, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36657459

RESUMEN

PURPOSE: The aim of this study was to investigate the reliability and reproducibility of transperineal ultrasound (TPUS) in the initial phase of labor. As TPUS is a common method, it could supplement vaginal palpation and even replace it in certain situations. In addition, we used a 4-dimensional method for the assessment of cervical effacement. MATERIALS AND METHODS: 54 women in labor were included and underwent TPUS. The resulting images from the acquired 4D volumes were evaluated after the examination for the first time and a second time after 21 days. The measured values were cervical length, dilatation and effacement, the angle of progression (AoP), and head-perineum distance. RESULTS: 54 patients were examined. TPUS images were unable to be evaluated in 12 patients because of cervical dilatation of more than 5 cm or poor image quality. Thus, 42 measurements were included. The concordance correlation coefficients according to Lin are satisfactory overall, with one exception for cervical effacement. The accuracy component of cervical length (CCCLin: 0.93; accuracy: 1.00), dilatation (CCCLin: 0.93; accuracy: 1.00), and AoP (CCCLin: 0.87; accuracy: 1.00) is excellent and still high for the head-perineum distance (CCCLin: 0.89; accuracy: 0.96) and cervical effacement (CCCLin: 0.77; accuracy: 0.97). CONCLUSION: TPUS is a valuable noninvasive tool with good diagnostic accuracy for the AoP, cervical length, and dilatation. Our study provides support for the use of TPUS to complement a vaginal examination. It should not replace a digital examination but should serve as a suitable alternative method for monitoring labor progression in the future.


Asunto(s)
Cuello del Útero , Ultrasonografía Prenatal , Embarazo , Humanos , Femenino , Proyectos Piloto , Reproducibilidad de los Resultados , Estudios Prospectivos , Ultrasonografía , Cuello del Útero/diagnóstico por imagen , Ultrasonografía Prenatal/métodos
4.
PLoS One ; 17(6): e0269395, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35657819

RESUMEN

INTRODUCTION: Comprehensive regular foot self-care is one of the most critical self-management behaviors for people with diabetes to prevent foot ulcer development and related complications. Yet, adequate foot self-care is only practiced by very few of those affected. To improve diabetic foot syndrome prevention, a valid and reliable instrument for measuring daily foot-care routines in patients with diabetes is needed. However, no such instrument is currently available in the German language. This study, therefore, aims to translate and cross-culturally adapt the "Diabetic Foot Self-Care Behavior Scale" (DFSBS) into German (DFSBS-D) and evaluate its validity and reliability. MATERIAL AND METHODS: The DFSBS was translated from English into German using a forward-backward procedure as per previous recommendations. Factor analysis was used to study structural validity. To establish construct validity, 21 a priori hypotheses were defined regarding the expected correlation between scores on the new German version (i.e., DFSBS-D) and those of the following questionnaires measuring related constructs: (1) German version "Diabetes Self-Care Activities Measure" (SDSCA-G), (2) "Frankfurter Catalogue of Foot Self-Care" (FCFSP), and (3) "Short Form 36" (SF-36) and tested in 82 patients. To assess test-retest reliability, patients completed the DFSBS-D again after a 2-week interval. Test-retest reliability was assessed from stable patients' data (n = 48) by calculating two-way random-effects absolute agreement ICCs with 95% CI and Bland and Altman analyses. In addition, Cronbach's alpha was calculated as internal consistency measure. RESULTS: The 7-item DFSBS-D showed good structural validity. Its single factor explains 57% of the total sample variance. Of the 21 predefined hypotheses, 13 (62%) were confirmed. The DFSBS-D's internal consistency was good (Cronbach's alpha = 0.87). Test-retest reliability over a 2-week interval was also good (ICC 0.76). CONCLUSION: The DFSBS was successfully translated into German. Statistical analyses showed good DFSBS-D structural validity, test-retest reliability, and internal consistency. Yet, construct validity may be debated.


Asunto(s)
Diabetes Mellitus , Pie Diabético , Estreñimiento , Diabetes Mellitus/terapia , Pie Diabético/terapia , Humanos , Lenguaje , Psicometría , Reproducibilidad de los Resultados , Autocuidado , Encuestas y Cuestionarios , Traducciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA