Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Anal Chem ; 95(27): 10211-10220, 2023 07 11.
Artículo en Inglés | MEDLINE | ID: mdl-37364037

RESUMEN

Respiratory infections are common in children, and there is a need for user-friendly collection methods. Here, we performed the first human subjects study using the CandyCollect device, a lollipop-inspired saliva collection device .We showed that the CandyCollect device can be used to collect salivary bacteria from healthy adults using Streptococcus mutans and Staphylococcus aureus as proof-of-concept commensal bacteria. We enrolled healthy adults in a nationwide (USA) remote study in which participants were sent study packages containing CandyCollect devices and traditional commercially available oral swabs and spit tubes. Participants sampled themselves at home, completed usability and user preference surveys, and mailed the samples back to our laboratory for analysis by qPCR. Our results showed that for participants in which a given bacterium (S. mutans or S. aureus) was detected in one or both of the commercially available methods (oral swab and/or spit tubes), CandyCollect devices had a 100% concordance with the positive result (n = 14 participants). Furthermore, the CandyCollect device was ranked the highest preference sampling method among the three sampling methods by 26 participants surveyed (combining survey results across two enrollment groups). We also showed that the CandyCollect device has a shelf life of up to 1 year at room temperature, a storage period that is convenient for clinics or patients to keep the CandyCollect device and use it any time. Taken together, we have demonstrated that the CandyCollect is a user-friendly saliva collection tool that has the potential to be incorporated into diagnostic assays in clinic visits and telemedicine.


Asunto(s)
Saliva , Staphylococcus aureus , Niño , Humanos , Adulto , Saliva/microbiología , Manejo de Especímenes/métodos , Streptococcus mutans , Laboratorios
2.
Anal Chem ; 93(33): 11433-11441, 2021 08 24.
Artículo en Inglés | MEDLINE | ID: mdl-34379402

RESUMEN

Aerosols dispersed and transmitted through the air (e.g., particulate matter pollution and bioaerosols) are ubiquitous and one of the leading causes of adverse health effects and disease transmission. A variety of sampling methods (e.g., filters, cyclones, and impactors) have been developed to assess personal exposures. However, a gap still remains in the accessibility and ease-of-use of these technologies for people without experience or training in collecting airborne samples. Additionally, wet scrubbers (large non-portable industrial systems) utilize liquid sprays to remove aerosols from the air; the goal is to "scrub" (i.e., clean) the exhaust of industrial smokestacks, not collect the aerosols for analysis. Inspired by wet scrubbers, we developed a device fundamentally different from existing portable air samplers by using aerosolized microdroplets to capture aerosols in personal spaces (e.g., homes, offices, and schools). Our aerosol-sampling device is the size of a small teapot, can be operated without specialized training, and features a winding flow path in a supersaturated relative humidity environment, enabling droplet growth. The integrated open mesofluidic channels shuttle coalesced droplets to a collection chamber for subsequent sample analysis. Here, we present the experimental demonstration of aerosol capture in water droplets. An iterative study optimized the non-linear flow manipulating baffles and enabled an 83% retention of the aerosolized microdroplets in the confined volume of our device. As a proof-of-concept for aerosol capture into a liquid medium, 0.5-3 µm model particles were used to evaluate aerosol capture efficiency. Finally, we demonstrate that the device can capture and keep a bioaerosol (bacteriophage MS2) viable for downstream analysis.


Asunto(s)
Levivirus , Material Particulado , Aerosoles/análisis , Microbiología del Aire , Monitoreo del Ambiente , Humanos , Tamaño de la Partícula
3.
Anal Chem ; 91(14): 8739-8750, 2019 07 16.
Artículo en Inglés | MEDLINE | ID: mdl-31260266

RESUMEN

Open microfluidic capillary systems are a rapidly evolving branch of microfluidics where fluids are manipulated by capillary forces in channels lacking physical walls on all sides. Typical channel geometries include grooves, rails, or beams and complex systems with multiple air-liquid interfaces. Removing channel walls allows access for retrieval (fluid sampling) and addition (pipetting reagents or adding objects like tissue scaffolds) at any point in the channel; the entire channel becomes a "device-to-world" interface, whereas such interfaces are limited to device inlets and outlets in traditional closed-channel microfluidics. Open microfluidic capillary systems are simple to fabricate and reliable to operate. Prototyping methods (e.g., 3D printing) and manufacturing methods (e.g., injection molding) can be used seamlessly, accelerating development. This Perspective highlights fundamentals of open microfluidic capillary systems including unique advantages, design considerations, fabrication methods, and analytical considerations for flow; device features that can be combined to create a "toolbox" for fluid manipulation; and applications in biology, diagnostics, chemistry, sensing, and biphasic applications.


Asunto(s)
Técnicas Analíticas Microfluídicas/instrumentación , Animales , Diseño de Equipo , Humanos , Hidrodinámica , Técnicas Analíticas Microfluídicas/métodos , Sistemas de Atención de Punto , Impresión Tridimensional
4.
Biomed Microdevices ; 21(1): 16, 2019 02 12.
Artículo en Inglés | MEDLINE | ID: mdl-30747285

RESUMEN

We present an open microfluidic platform that enables stable flow of an organic solvent over an aqueous solution. The device features apertures connecting a lower aqueous channel to an upper solvent compartment that is open to air, enabling easy removal of the solvent for analysis. We have previously shown that related open biphasic systems enable steroid hormone extraction from human cells in microscale culture and secondary metabolite extraction from microbial culture; here we build on our prior work by determining conditions under which the system can be used with extraction solvents of ranging polarities, a critical feature for applying this extraction platform to diverse classes of metabolites. We developed an analytical model that predicts the limits of stable aqueous-organic interfaces based on analysis of Laplace pressure. With this analytical model and experimental testing, we developed generalized design rules for creating stable open microfluidic biphasic systems with solvents of varying densities, aqueous-organic interfacial tensions, and polarities. The stable biphasic interfaces afforded by this device will enable on-chip extraction of diverse metabolite structures and novel applications in microscale biphasic chemical reactions.


Asunto(s)
Hormonas Esteroides Gonadales/aislamiento & purificación , Microfluídica , Línea Celular Tumoral , Hormonas Esteroides Gonadales/metabolismo , Humanos , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Microfluídica/instrumentación , Microfluídica/métodos , Propiedades de Superficie
5.
bioRxiv ; 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38798664

RESUMEN

Sperm cryopreservation is important for individuals undergoing infertility treatment, and for those who wish to preserve fertility potential, prior to treatments like chemotherapy, radiation therapy, gender-affirming medical interventions, elective fertility delay, or individuals in high-risk professions such as the military. Current methods for sperm cryopreservation result in approximately 30-50% decrease in sperm motility. However, recent studies have shown that ultra-rapid freezing (vitrification) is a valuable approach for maintaining sperm quality after freeze-thawing processes in the clinical laboratory setting and requires submicroliter to microliter volumes. A major challenge for the adoption of vitrification in fertility laboratories is the ability to pipette small volumes of sample. Here, we present a method that leverages open-channel droplet microfluidics to autonomously generate sub-microliter to microliter volumes of purified human sperm samples. Using a novel, open-channel droplet generator, we found no change in sperm movement and kinematic data after exposure to device and reagents in our platform. We conclude that our platform is compatible with human sperm, an important foundation for future implementation of vitrification in fertility laboratories.

6.
bioRxiv ; 2023 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-36711895

RESUMEN

Respiratory infections are common in children, and there is a need for user-friendly collection methods. Here, we performed the first human subjects study using the CandyCollect device, a lollipop inspired saliva collection device. 1 We showed the CandyCollect device can be used to collect salivary bacteria from healthy adults using Streptococcus mutans and Staphylococcus aureus as proof-of-concept commensal bacteria. We enrolled healthy adults in a nationwide (USA) remote study in which participants were sent study packages containing CandyCollect devices and traditional commercially available oral swabs and spit tubes. Participants sampled themselves at home, completed usability and user preference surveys, and mailed the samples back to our laboratory for analysis by qPCR. Our results showed that for participants in which a given bacterium ( S. mutans or S. aureus ) was detected in one or both of the commercially available methods (oral swab and/or spit tubes), CandyCollect devices had a 100% concordance with the positive result (n=14 participants). Furthermore, the CandyCollect device was ranked the highest preference sampling method among the three sampling methods by 26 participants surveyed (combining survey results across two enrollment groups). We also showed that the CandyCollect device has a shelf life of up to 1 year at room temperature, a storage period that is convenient for clinics or patients to keep the CandyCollect device and use it any time. Taken together, we have demonstrated that the CandyCollect is a user-friendly saliva collection tool that has the potential to be incorporated into diagnostic assays in clinic visits and telemedicine.

7.
SLAS Technol ; 27(6): 344-349, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35970321

RESUMEN

Lumen structures exist throughout the human body, and the vessels of the circulatory system are essential for carrying nutrients and oxygen and regulating inflammation. Vasodilation, the widening of the blood vessel lumen, is important to the immune response as it increases blood flow to a site of inflammation, raises local temperature, and enables optimal immune system function. A common method for studying vasodilation uses excised vessels from animals; major drawbacks include heterogeneity in vessel shape and size, time-consuming procedures, sacrificing animals, and differences between animal and human biology. We have developed a simple, user-friendly in vitro method to form freestanding cell-laden hydrogel rings from collagen and quantitatively measure the effects of vasodilators on ring size. The hydrogel rings are composed of collagen I and can be laden with human vascular smooth muscle cells, a major cellular and structural component of blood vessels, or lined with endothelial cells in the lumen. The methods presented include a 3D printed device (which is amenable to future fabrication by injection molding) and commercially available components (e.g., Teflon tubing or a syringe) to form hydrogel rings between 2.6-4.6 mm outer diameter and 0.79-1.0 mm inner diameter. Here we demonstrate a significant difference in ring area in the presence of a known vasodilator, fasudil (p < 0.0001). Our method is easy to implement and provides a foundation for a medium-throughput solution to generating vessel model structures for future investigations of the fundamental mechanisms of vasodilation (e.g., studying uncharacterized endogenous molecules that may have vasoactivity) and testing vasoactive drugs.


Asunto(s)
Células Endoteliales , Hidrogeles , Animales , Humanos , Hidrogeles/química , Cuerpo Humano , Colágeno/química , Inyecciones
8.
Front Bioeng Biotechnol ; 10: 993872, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36246374

RESUMEN

Interactions between fibroblasts and immune cells play an important role in tissue inflammation. Previous studies have found that eosinophils activated with interleukin-3 (IL-3) degranulate on aggregated immunoglobulin G (IgG) and release mediators that activate fibroblasts in the lung. However, these studies were done with eosinophil-conditioned media that have the capacity to investigate only one-way signaling from eosinophils to fibroblasts. Here, we demonstrate a coculture model of primary normal human lung fibroblasts (HLFs) and human blood eosinophils from patients with allergy and asthma using an open microfluidic coculture device. In our device, the two types of cells can communicate via two-way soluble factor signaling in the shared media while being physically separated by a half wall. Initially, we assessed the level of eosinophil degranulation by their release of eosinophil-derived neurotoxin (EDN). Next, we analyzed the inflammation-associated genes and soluble factors using reverse transcription quantitative polymerase chain reaction (RT-qPCR) and multiplex immunoassays, respectively. Our results suggest an induction of a proinflammatory fibroblast phenotype of HLFs following the coculture with degranulating eosinophils, validating our previous findings. Additionally, we present a new result that indicate potential impacts of activated HLFs back on eosinophils. This open microfluidic coculture platform provides unique opportunities to investigate the intercellular signaling between the two cell types and their roles in airway inflammation and remodeling.

9.
Lab Chip ; 22(18): 3555-3564, 2022 09 13.
Artículo en Inglés | MEDLINE | ID: mdl-35983761

RESUMEN

Streptococcus pyogenes is a major human-specific bacterial pathogen and a common cause of a wide range of symptoms from mild infection such as pharyngitis (commonly called strep throat) to life-threatening invasive infection and post-infectious sequelae. Traditional methods for diagnosis include collecting a sample using a pharyngeal swab, which can cause discomfort and even discourage adults and children from seeking proper testing and treatment in the clinic. Saliva samples are an alternative to pharyngeal swabs. To improve the testing experience for strep throat, we developed a novel lollipop-inspired sampling platform (called CandyCollect) to capture bacteria in saliva. The device can be used in clinics or in the home and shipped back to a lab for analysis, integrating with telemedicine. CandyCollect is designed to capture bacteria on an oxygen plasma treated polystyrene surface embedded with flavoring substances to enhance the experience for children and inform the required time to complete the sampling process. In addition, the open channel structure prevents the tongue from scraping and removing the captured bacteria. The flavoring substances did not affect bacterial capture and the device has a shelf life of at least 2 months (with experiments ongoing to extend the shelf life). We performed a usability study with 17 participants who provided feedback on the device design and the dissolving time of the candy. This technology and advanced processing techniques, including polymerase chain reaction (PCR), will enable user-friendly and effective diagnosis of streptococcal pharyngitis.


Asunto(s)
Faringitis , Infecciones Estreptocócicas , Adulto , Niño , Humanos , Faringitis/diagnóstico , Faringitis/microbiología , Reacción en Cadena de la Polimerasa , Saliva , Infecciones Estreptocócicas/diagnóstico , Infecciones Estreptocócicas/microbiología , Streptococcus pyogenes/genética
10.
Lab Chip ; 20(3): 525-536, 2020 02 07.
Artículo en Inglés | MEDLINE | ID: mdl-31915779

RESUMEN

Patterned deposition and 3D fabrication techniques have enabled the use of hydrogels for a number of applications including microfluidics, sensors, separations, and tissue engineering in which form fits function. Devices such as reconfigurable microvalves or implantable tissues have been created using lithography or casting techniques. Here, we present a novel open-microfluidic patterning method that utilizes surface tension forces to form hydrogel layers on top of each other, into a patterned 3D structure. We use a patterning device to form a temporary open microfluidic channel on an existing gel layer, allowing the controlled flow of unpolymerized gel in device-regions. After layer gelation and device removal, the process can be repeated iteratively to create multi-layered 3D structures. The use of open-microfluidic and surface tension-based methods to define the shape of each individual layer enables patterning to be performed with a simple pipette and with minimal dead-volume. Our method is compatible with unmodified (native) biological hydrogels, and other non-biological materials with precursor fluid properties compatible with capillary flow. With our open-microfluidic layer-by-layer fabrication method, we demonstrate the capability to build agarose, type I collagen, and polymer-peptide 3D structures featuring asymmetric designs, multiple components, overhanging features, and cell-laden regions.


Asunto(s)
Hidrogeles/química , Dispositivos Laboratorio en un Chip , Técnicas Analíticas Microfluídicas , Células Cultivadas , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Técnicas Analíticas Microfluídicas/instrumentación , Polietilenglicoles/química
11.
Lab Chip ; 18(3): 496-504, 2018 01 30.
Artículo en Inglés | MEDLINE | ID: mdl-29309079

RESUMEN

Microscale cell-based assays have demonstrated unique capabilities in reproducing important cellular behaviors for diagnostics and basic biological research. As these assays move beyond the prototyping stage and into biological and clinical research environments, there is a need to produce microscale culture platforms more rapidly, cost-effectively, and reproducibly. 'Rapid' injection molding is poised to meet this need as it enables some of the benefits of traditional high volume injection molding at a fraction of the cost. However, rapid injection molding has limitations due to the material and methods used for mold fabrication. Here, we characterize advantages and limitations of rapid injection molding for microfluidic device fabrication through measurement of key features for cell culture applications including channel geometry, feature consistency, floor thickness, and surface polishing. We demonstrate phase contrast and fluorescence imaging of cells grown in rapid injection molded devices and provide design recommendations to successfully utilize rapid injection molding methods for microscale cell-based assay development in academic laboratory settings.


Asunto(s)
Técnicas de Cultivo de Célula/instrumentación , Diseño Asistido por Computadora , Diseño de Equipo/métodos , Técnicas Analíticas Microfluídicas/instrumentación , Animales , Bovinos , Línea Celular , Microscopía Fluorescente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA