Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Neurogastroenterol Motil ; 33(6): e14009, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33094875

RESUMEN

BACKGROUND: Esophagogastric junction contractile integral (EGJ-CI) and EGJ morphology are high-resolution manometry (HRM) metrics that assess EGJ barrier function. Normative data standardized across world regions and HRM manufacturers are limited. METHODS: Our aim was to determine normative EGJ metrics in a large international cohort of healthy volunteers undergoing HRM (Medtronic, Laborie, and Diversatek software) acquired from 16 countries in four world regions. EGJ-CI was calculated by the same two investigators using a distal contractile integral-like measurement across the EGJ for three respiratory cycles and corrected for respiration (mm Hg cm), using manufacturer-specific software tools. EGJ morphology was designated according to Chicago Classification v3.0. Median EGJ-CI values were calculated across age, genders, HRM systems, and regions. RESULTS: Of 484 studies (28.0 years, 56.2% F, 60.7% Medtronic studies, 26.0% Laborie, and 13.2% Diversatek), EGJ morphology was type 1 in 97.1%. Median EGJ-CI was similar between Medtronic (37.0 mm Hg cm, IQR 23.6-53.7 mm Hg cm) and Diversatek (34.9 mm Hg cm, IQR 22.1-56.1 mm Hg cm, P = 0.87), but was significantly higher using Laborie equipment (56.5 mm Hg cm, IQR 35.0-75.3 mm Hg cm, P < 0.001). 5th percentile EGJ-CI values ranged from 6.9 to 12.1 mm Hg cm. EGJ-CI values were consistent across world regions, but different between manufacturers even within the same world region (P ≤ 0.001). Within Medtronic studies, EGJ-CI and basal LESP were similar in younger and older individuals (P ≥ 0.3) but higher in women (P < 0.001). CONCLUSIONS: EGJ morphology is predominantly type 1 in healthy adults. EGJ-CI varies widely in health, with significant gender influence, but is consistent within each HRM system. Manufacturer-specific normative values should be utilized for clinical HRM interpretation.


Asunto(s)
Unión Esofagogástrica/anatomía & histología , Unión Esofagogástrica/fisiología , Manometría/métodos , Adolescente , Adulto , Anciano , Envejecimiento/fisiología , Estudios de Cohortes , Unión Esofagogástrica/diagnóstico por imagen , Femenino , Reflujo Gastroesofágico/fisiopatología , Voluntarios Sanos , Humanos , Masculino , Manometría/instrumentación , Persona de Mediana Edad , Contracción Muscular/fisiología , Valores de Referencia , Mecánica Respiratoria , Caracteres Sexuales , Programas Informáticos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA