Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Acta Obstet Gynecol Scand ; 102(10): 1290-1297, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37350333

RESUMEN

INTRODUCTION: Pelvic floor pain and dyspareunia are both important entities of postpartum pelvic pain, often concomitant and associated with perineal tears during vaginal delivery. The association between postpartum sonographic anal sphincter defects, pelvic floor pain, and dyspareunia has not been fully established. We aimed to determine the prevalence of postpartum anal sphincter defects using three-dimensional endoanal ultrasonography (3D-EAUS) and evaluate their association with symptoms of pelvic floor pain and dyspareunia. MATERIAL AND METHODS: This prospective cohort study followed 239 primiparas from birth to 12 months post delivery. Anal sphincters were assessed with 3D-EAUS 3 months postpartum, and self-reported pelvic floor function data were obtained using a web-based questionnaire distributed 1 year after delivery. Descriptive statistics were compared between the patients with and without sonographic defects, and the association between sonographic sphincter defects and outcomes were analyzed using logistic regression. RESULTS: At 3 months postpartum, 48/239 (20%) patients had anal sphincter defects on 3D-EAUS, of which 43 (18%) were not clinically diagnosed with obstetric anal sphincter injury at the time of delivery. Patients with sonographic defects had higher fetal weight than those without defects, and a perineum <2 cm before the suture was a risk factor for defects (odds ratio [OR], 6.9). Patients with sonographic defects had a higher frequency of dyspareunia (OR, 2.4), and pelvic floor pain (OR, 2.3) than those without defects. CONCLUSIONS: Our results suggest an association between postpartum sonographic anal sphincter defects, pelvic floor pain, and dyspareunia. A perineal height <2 cm, measured by bidigital palpation immediately postdelivery, was a risk factor for sonographic anal sphincter defect. We suggest offering pelvic floor sonography around 3 months postpartum to high- risk women to optimize diagnosis and treatment of perineal tears and include perineum <2 cm prior to primary repair as a proposed indication for postpartum follow-up sonography.


Asunto(s)
Dispareunia , Incontinencia Fecal , Laceraciones , Embarazo , Humanos , Femenino , Canal Anal/diagnóstico por imagen , Canal Anal/lesiones , Estudios Prospectivos , Diafragma Pélvico/diagnóstico por imagen , Diafragma Pélvico/lesiones , Dispareunia/diagnóstico por imagen , Dispareunia/epidemiología , Dispareunia/etiología , Periodo Posparto , Parto Obstétrico/efectos adversos , Parto Obstétrico/métodos , Ultrasonografía , Laceraciones/complicaciones , Dolor Pélvico/diagnóstico por imagen , Dolor Pélvico/epidemiología , Dolor Pélvico/etiología , Incontinencia Fecal/diagnóstico por imagen , Incontinencia Fecal/epidemiología , Incontinencia Fecal/etiología
2.
Acta Obstet Gynecol Scand ; 102(3): 389-395, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36683208

RESUMEN

INTRODUCTION: Obstetric anal sphincter injury (OASI) complicates around 5% of deliveries in primiparas. The study objective was to assess the utility of three-dimensional endoanal ultrasonography (3D-EAUS) in the diagnosis of OASI. MATERIAL AND METHODS: The present study was designed to mirror screening settings with an unselected cohort of nulliparous women. All enrolled patients underwent clinical examination of the perineum by the caregiver, and 3D-EAUS was conducted. Post-processing of ultrasonography volume data was performed by an experienced colorectal surgeon who was blinded to all other data. The sensitivity, specificity, negative predictive value, and positive predictive value of 3D-EAUS in the diagnosis of OASI was evaluated. The trial is registered at ISCRTN: 18006769. RESULTS: A total of 680 scans were performed, of which 18.5% were judged as "non-assessable", resulting in 554 assessable recordings. Sphincter defects were observed in 12.8% of all assessable recordings on 3D-EAUS (n = 71). With clinical examination set as the reference standard, ultrasound sensitivity in the diagnosis of OASI was 30.4%, whereas its specificity was 87.9%. The negative predictive value was 96.7% and the positive predictive value was only 9.9%. Comments were left on 175 examinations, of which 74% referred to the management of the examination. CONCLUSIONS: Using 3D-EAUS in a maternity ward is demanding because staff generally have little experience in endoanal ultrasound, which contributes to difficulties in obtaining good image quality. When 3D-EAUS is performed to mirror screening settings, it adds no convincing diagnostic power to clinical examination in the diagnosis of OASI.


Asunto(s)
Canal Anal , Incontinencia Fecal , Femenino , Humanos , Embarazo , Canal Anal/diagnóstico por imagen , Canal Anal/lesiones , Parto Obstétrico/efectos adversos , Endosonografía , Incontinencia Fecal/etiología , Paridad , Parto , Valor Predictivo de las Pruebas , Ultrasonografía/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA