Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Biomacromolecules ; 25(4): 2312-2322, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38456765

RESUMEN

Local delivery of pain medication can be a beneficial strategy to address pain management after joint replacement, as it can decrease systemic opioid usage, leading to less side and long-term effects. In this study, we used ultrahigh molecular weight polyethylene (UHMWPE), commonly employed as a bearing material for joint implants, to deliver a wide set of analgesics and the nonsteroidal anti-inflammatory drug tolfenamic acid. We blended the drugs with UHMWPE and processed the blend by compression molding and sterilization by low-dose gamma irradiation. We studied the chemical stability of the eluted drugs, drug elution, tensile properties, and wear resistance of the polymer blends before and after sterilization. The incorporation of bupivacaine hydrochloride and tolfenamic acid in UHMWPE resulted in either single- or dual-drug loaded materials that can be sterilized by gamma irradiation. These compositions were found to be promising for the development of clinically relevant drug-eluting implants for joint replacement.


Asunto(s)
Artroplastia de Reemplazo , ortoaminobenzoatos , Ensayo de Materiales , Polietilenos/química , Analgésicos , Antiinflamatorios no Esteroideos
2.
Curr Osteoporos Rep ; 17(6): 455-464, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31713179

RESUMEN

PURPOSE OF REVIEW: Individuals with type 1 and type 2 diabetes mellitus (T1DM, T2DM) have an increased risk of bone fracture compared to non-diabetic controls that is not explained by differences in BMD, BMI, or falls. Thus, bone tissue fracture resistance may be reduced in individuals with DM. The purpose of this review is to summarize work that analyzes the effects of T1DM and T2DM on bone tissue compositional and mechanical properties. RECENT FINDINGS: Studies of clinical T2DM specimens revealed increased mineralization and advanced glycation endproduct (AGE) concentrations and significant relationships between mechanical performance and composition of cancellous bone. Specifically, in femoral cancellous tissue, compressive stiffness and strength increased with mineral content; and post-yield properties decreased with AGE concentration. In addition, cortical resistance to in vivo indentation (bone material strength index) was lower in patients with T2DM vs. age-matched non-diabetic controls, and this resistance decreased with worsening glycemic control. Recent studies on patients with T1DM and history of a prior fragility fracture found greater mineral content and concentrations of AGEs in iliac trabecular bone and correspondingly stiffer, harder bone at the nanosacle. Recent observational data showed greater AGE and mineral content in surgically retrieved bone from patients with T2DM vs. non-DM controls, consistent with reduced bone remodeling. Limited data on human T1DM bone tissue also showed higher mineral and AGE content in patients with prior fragility fractures compared to non-DM and non-fracture controls.


Asunto(s)
Remodelación Ósea , Huesos/fisiopatología , Diabetes Mellitus Tipo 1/fisiopatología , Diabetes Mellitus Tipo 2/fisiopatología , Animales , Fenómenos Biomecánicos , Glucemia/metabolismo , Densidad Ósea , Huesos/diagnóstico por imagen , Huesos/metabolismo , Hueso Esponjoso/diagnóstico por imagen , Hueso Esponjoso/metabolismo , Hueso Esponjoso/fisiopatología , Hueso Cortical/diagnóstico por imagen , Hueso Cortical/metabolismo , Hueso Cortical/fisiopatología , Diabetes Mellitus Experimental/metabolismo , Diabetes Mellitus Experimental/fisiopatología , Diabetes Mellitus Tipo 1/epidemiología , Diabetes Mellitus Tipo 1/metabolismo , Diabetes Mellitus Tipo 2/epidemiología , Diabetes Mellitus Tipo 2/metabolismo , Fracturas Óseas/epidemiología , Productos Finales de Glicación Avanzada/metabolismo , Humanos
3.
J Orthop Res ; 42(2): 460-473, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-37609941

RESUMEN

Periprosthetic joint infections occur in about 2% of patients who undergo primary total joint arthroplasty, a procedure performed over 1 million times in the United States. The gold standard of treatment is a two-stage revision. This study aimed to establish a two-stage procedure in a preclinical small animal model (rat) to test and compare the efficacy of an antibiotic-eluting material in managing infection. Joint replacement was simulated by transchondylarly implanting a polyethylene (PE) plug into the distal femur and a titanium screw in the proximal tibia. Methicillin-sensitive Staphylococcus aureus (MSSA) 108 CFU/mL was injected into the tibial canal and the joint space before wound closure. The control groups were killed on postoperative day (POD) 18 (n = 12) and on POD 42 (n = 4) to assess both early and later-stage outcomes in the control group. The test group underwent revision surgery on POD 18 for treatment using gentamicin-eluting polyethylene (GPE, n = 4) and was observed until POD 42 to evaluate the efficacy of treatment. Our results showed that the bone loss for the treatment group receiving GPE was significantly less than that of the control (p < 0.05), which was supported by the histology images and an AI-tool assisted infection rate evaluation. Gait metrics duty factor imbalance and hindlimb temporal symmetry were significantly different between the treatment and control groups on Day 42. This animal model was feasible for evaluating treatments for peri-prosthetic joint infections (PJI) with a revision surgery and specifically that revision surgery and local antibiotic treatment largely hindered the peri-prosthetic bone loss. Statement of clinical significance: This revision model of peri-prosthetic infection has the potential of comparatively evaluating prophylaxis and treatment strategies and devices. Antibiotic-eluting UHMWPE is devised as at tool in treating PJI while providing weight bearing and joint space preservation.


Asunto(s)
Artritis Infecciosa , Infecciones Relacionadas con Prótesis , Humanos , Ratas , Animales , Antibacterianos/uso terapéutico , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Infecciones Relacionadas con Prótesis/cirugía , Artritis Infecciosa/tratamiento farmacológico , Gentamicinas/uso terapéutico , Reoperación , Polietilenos , Estudios Retrospectivos
4.
Macromol Biosci ; 24(4): e2300389, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38095273

RESUMEN

The occurrence of periprosthetic joint infections (PJI) after total joint replacement constitutes a great burden for the patients and the healthcare system. Antibiotic-loaded polymethylmethacrylate (PMMA) bone cement is often used in temporary spacers during antibiotic treatment. PMMA is not a load-bearing solution and needs to be replaced by a functional implant. Elution from the ultrahigh molecular weight polyethylene (UHMWPE) bearing surface for drug delivery can combine functionality with the release of clinically relevant doses of antibiotics. In this study, the feasibility of incorporating a range of antibiotics into UHMWPE is investigated. Drug stability is assessed by thermo-gravimetric analysis and nuclear magnetic resonance spectroscopy. Drug-loaded UHMWPEs are prepared by compression molding, using eight antibiotics at different loading. The predicted intra-articular concentrations of drugs eluted from UHMWPE are above minimum inhibitory concentration for at least 3 weeks against Staphylococci, which are the major causative bacteria for PJI. The antibacterial efficacy is confirmed for samples covering 2% of a representative knee implant in vitro over 72 h, showing that a small fraction of the implant surface loaded with antibiotics may be sufficient against Staphylococci.


Asunto(s)
Antibacterianos , Infecciones Relacionadas con Prótesis , Humanos , Antibacterianos/farmacología , Antibacterianos/uso terapéutico , Polimetil Metacrilato/química , Peso Molecular , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/microbiología , Polietilenos/farmacología , Cementos para Huesos/farmacología
5.
Animal Model Exp Med ; 7(2): 145-155, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38525803

RESUMEN

BACKGROUND: Arthrofibrosis is a joint disorder characterized by excessive scar formation in the joint tissues. Vitamin E is an antioxidant with potential anti-fibroblastic effect. The aim of this study was to establish an arthrofibrosis rat model after joint replacement and assess the effects of vitamin E supplementation on joint fibrosis. METHODS: We simulated knee replacement in 16 male Sprague-Dawley rats. We immobilized the surgical leg with a suture in full flexion. The control groups were killed at 2 and 12 weeks (n = 5 per group), and the test group was supplemented daily with vitamin E (0.2 mg/mL) in their drinking water for 12 weeks (n = 6). We performed histological staining to investigate the presence and severity of arthrofibrosis. Immunofluorescent staining and α2-macroglobulin (α2M) enzyme-linked immunosorbent assay (ELISA) were used to assess local and systemic inflammation. Static weight bearing (total internal reflection) and range of motion (ROM) were collected for functional assessment. RESULTS: The ROM and weight-bearing symmetry decreased after the procedure and recovered slowly with still significant deficit at the end of the study for both groups. Histological analysis confirmed fibrosis in both lateral and posterior periarticular tissue. Vitamin E supplementation showed a moderate anti-inflammatory effect on the local and systemic levels. The vitamin E group exhibited significant improvement in ROM and weight-bearing symmetry at day 84 compared to the control group. CONCLUSIONS: This model is viable for simulating arthrofibrosis after joint replacement. Vitamin E may benefit postsurgical arthrofibrosis, and further studies are needed for dosing requirements.


Asunto(s)
Fibrosis , Rango del Movimiento Articular , Ratas Sprague-Dawley , Vitamina E , Animales , Vitamina E/farmacología , Vitamina E/administración & dosificación , Vitamina E/uso terapéutico , Masculino , Ratas , Rango del Movimiento Articular/efectos de los fármacos , Artroplastia de Reemplazo de Rodilla , Artropatías/prevención & control , Artropatías/etiología , Modelos Animales de Enfermedad
6.
PLoS One ; 19(6): e0296140, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38900759

RESUMEN

Implant-associated osteomyelitis remains a major orthopaedic problem. As neutrophil swarming to the surgical site is a critical host response to prevent infection, visualization and quantification of this dynamic behavior at the native microenvironment of infection will elucidate previously unrecognized mechanisms central to understanding the host response. We recently developed longitudinal intravital imaging of the bone marrow (LIMB) to visualize host cells and fluorescent S. aureus on a contaminated transfemoral implant in live mice, which allows for direct visualization of bacteria colonization of the implant and host cellular responses using two-photon laser scanning microscopy. To the end of rigorous and reproducible quantitative outcomes of neutrophil swarming kinetics in this model, we developed a protocol for robust segmentation, tracking, and quantifications of neutrophil dynamics adapted from Trainable Weka Segmentation and TrackMate, two readily available Fiji/ImageJ plugins. In this work, Catchup mice with tdTomato expressing neutrophils received a transfemoral pin with or without ECFP/EGFP-expressing USA300 methicillin-resistant Staphylococcus aureus (MRSA) to obtain 30-minute LIMB videos at 2-, 4-, and 6-hours post-implantation. The developed semi-automated neutrophil tracking protocol was executed independently by two users to quantify the distance, displacement, speed, velocity, and directionality of the target cells. The results revealed high inter-user reliability for all outcomes (ICC > 0.96; p > 0.05). Consistent with the established paradigm on increased neutrophil swarming during active infection, the results also demonstrated increased neutrophil speed and velocity at all measured time points, and increased displacement at later time points (6 hours) in infected versus uninfected mice (p < 0.05). Neutrophils and bacteria also exhibit directionality during migration in the infected mice. The semi-automated cell tracking protocol provides a streamlined approach to robustly identify and track individual cells across diverse experimental settings and eliminates inter-observer variability.


Asunto(s)
Rastreo Celular , Fémur , Neutrófilos , Animales , Neutrófilos/inmunología , Ratones , Fémur/microbiología , Rastreo Celular/métodos , Infecciones Estafilocócicas/microbiología , Infecciones Estafilocócicas/inmunología , Modelos Animales de Enfermedad , Osteomielitis/microbiología , Staphylococcus aureus Resistente a Meticilina/fisiología , Infecciones Relacionadas con Prótesis/microbiología , Prótesis e Implantes/microbiología , Staphylococcus aureus/fisiología , Femenino
7.
J Orthop Res ; 42(3): 531-538, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37812184

RESUMEN

Critical knowledge gaps of orthopedic infections pertain to bacterial colonization. The established dogma termed the Race for the Surface posits that contaminating bacteria compete with host cells for the implant post-op, which remains unproven without real-time in vivo evidence. Thus, we modified the murine longitudinal intravital imaging of the bone marrow (LIMB) system to allow real-time quantification of green fluorescent protein (GFP+) host cells and enhanced cyan fluorescent protein (ECFP+) or red fluorescent protein (RFP+) methicillin-resistant Staphylococcus aureus (MRSA) proximal to a transfemoral implant. Following inoculation with ~105 CFU, an L-shaped metal implant was press-fit through the lateral cortex at a 90° angle ~0.150 mm below a gradient refractive index (GRIN) lens. We empirically derived a volume of interest (VOI) = 0.0161 ± 0.000675 mm3 during each imaging session by aggregating the Z-stacks between the first (superior) and last (inferior) in-focus LIMB slice. LIMB postimplantation revealed very limited bacteria detection at 1 h, but by 3 h, 56.8% of the implant surface was covered by ECFP+ bacteria, and the rest were covered by GFP+ host cells. 3D volumetric rendering of the GFP+ and ECFP+ or RFP+ voxels demonstrated exponential MRSA growth between 3 and 6 h in the Z-plane, which was validated with cross-sectional ex vivo bacterial burden analyses demonstrating significant growth by ~2 × 104 CFU/h on the implant from 2 to 12 h post-op (p < 0.05; r2 > 0.98). Collectively, these results show the competition at the surface is completed by 3 h in this model and demonstrate the potential of LIMB to elucidate mechanisms of bacterial colonization, the host immune response, and the efficacy of antimicrobials.


Asunto(s)
Staphylococcus aureus Resistente a Meticilina , Osteomielitis , Infecciones Estafilocócicas , Ratones , Animales , Antibacterianos/uso terapéutico , Infecciones Estafilocócicas/diagnóstico por imagen , Infecciones Estafilocócicas/tratamiento farmacológico , Médula Ósea , Estudios Transversales , Osteomielitis/tratamiento farmacológico , Modelos Animales de Enfermedad
8.
J Vis Exp ; (193)2023 03 03.
Artículo en Inglés | MEDLINE | ID: mdl-36939249

RESUMEN

Ultrahigh molecular weight polyethylene (UHMWPE) is widely used in total joint arthroplasties as a load-bearing surface. Periprosthetic joint infections, the majority of which occur shortly after joint replacement, constitute almost 25% of total knee revision surgeries, and the complete eradication of bacterial infection poses a major challenge. A promising way to tackle this problem is to ensure the local sustained delivery of antibiotic concentrations sufficient to inhibit the bacteria to support routine systemic antibiotic prophylaxis. There is increased research into the development of efficient local drug delivery devices. Although established antibacterial testing methods for drugs can be used to test the antibacterial efficacy of drug-eluting materials, they are lacking in terms of providing real-time and longitudinal antibacterial efficacy data that can be correlated to the elution profiles of antibiotics from these devices. Here, we report a direct and versatile methodology to determine the antibacterial efficacy of antibiotic-eluting UHMWPE implants. This methodology can be used as a platform to avoid bacterial culture at each time point of a lengthy experiment and can also be adapted to other local drug delivery devices.


Asunto(s)
Infecciones Bacterianas , Infecciones Relacionadas con Prótesis , Humanos , Polietilenos/uso terapéutico , Antibacterianos/farmacología , Antibacterianos/uso terapéutico , Sistemas de Liberación de Medicamentos
9.
J Bone Miner Res ; 38(2): 261-277, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36478472

RESUMEN

Individuals with type 2 diabetes mellitus (T2DM) have a greater risk of bone fracture compared with those with normal glucose tolerance (NGT). In contrast, individuals with impaired glucose tolerance (IGT) have a lower or similar risk of fracture. Our objective was to understand how progressive glycemic derangement affects advanced glycation endproduct (AGE) content, composition, and mechanical properties of iliac bone from postmenopausal women with NGT (n = 35, age = 65 ± 7 years, HbA1c = 5.8% ± 0.3%), IGT (n = 26, age = 64 ± 5 years, HbA1c = 6.0% ± 0.4%), and T2DM on insulin (n = 25, age = 64 ± 6 years, HbA1c = 9.1% ± 2.2%). AGEs were assessed in all samples using high-performance liquid chromatography to measure pentosidine and in NGT/T2DM samples using multiphoton microscopy to spatially resolve the density of fluorescent AGEs (fAGEs). A subset of samples (n = 14 NGT, n = 14 T2DM) was analyzed with nanoindentation and Raman microscopy. Bone tissue from the T2DM group had greater concentrations of (i) pentosidine versus IGT (cortical +24%, p = 0.087; trabecular +35%, p = 0.007) and versus NGT (cortical +40%, p = 0.003; trabecular +35%, p = 0.004) and (ii) fAGE cross-link density versus NGT (cortical +71%, p < 0.001; trabecular +44%, p < 0.001). Bone pentosidine content in the IGT group was lower than in the T2DM group and did not differ from the NGT group, indicating that the greater AGE content observed in T2DM occurs with progressive diabetes. Individuals with T2DM on metformin had lower cortical bone pentosidine compared with individuals not on metformin (-35%, p = 0.017). Cortical bone from the T2DM group was stiffer (+9%, p = 0.021) and harder (+8%, p = 0.039) versus the NGT group. Bone tissue AGEs, which embrittle bone, increased with worsening glycemic control assessed by HbA1c (Pen: R2  = 0.28, p < 0.001; fAGE density: R2  = 0.30, p < 0.001). These relationships suggest a potential mechanism by which bone fragility may increase despite greater tissue stiffness and hardness in individuals with T2DM; our results suggest that it occurs in the transition from IGT to overt T2DM. © 2022 American Society for Bone and Mineral Research (ASBMR).


Asunto(s)
Diabetes Mellitus Tipo 2 , Fracturas Óseas , Intolerancia a la Glucosa , Metformina , Humanos , Femenino , Persona de Mediana Edad , Anciano , Diabetes Mellitus Tipo 2/complicaciones , Insulina , Hemoglobina Glucada , Ilion , Dureza , Posmenopausia , Glucosa , Glucemia
10.
bioRxiv ; 2023 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-38105961

RESUMEN

Implant-associated osteomyelitis remains a major orthopaedic problem. As neutrophil swarming to the surgical site is a critical host response to prevent infection, visualization and quantification of this dynamic behavior at the native microenvironment of infection will elucidate previously unrecognized mechanisms central to understanding the host response. We recently developed longitudinal intravital imaging of the bone marrow (LIMB) to visualize fluorescent S. aureus on a contaminated transfemoral implant and host cells in live mice, which allows for direct visualization of bacteria colonization of the implant and host cellular responses using two-photon laser scanning microscopy. To the end of rigorous and reproducible quantitative outcomes of neutrophil swarming kinetics in this model, we developed a protocol for robust segmentation, tracking, and quantifications of neutrophil dynamics adapted from Trainable Weka Segmentation and TrackMate, two readily available Fiji/ImageJ plugins. In this work, Catchup mice with tdTomato expressing neutrophils received a transfemoral pin with or without ECFP-expressing USA300 methicillin-resistant Staphylococcus aureus (MRSA) to obtain 30-minute LIMB videos at 2-, 4-, and 6-hours post-implantation. The developed semi-automated neutrophil tracking protocol was executed independently by two users to quantify the distance, displacement, speed, velocity, and directionality of the target cells. The results revealed high inter-reader reliability for all outcomes (ICC > 0.98; p > 0.05). Consistent with the established paradigm on increased neutrophil swarming during active infection, the results also demonstrated increased neutrophil speed and velocity at all measured time points, and increased displacement at later time points (6 hours) in infected versus uninfected mice (p < 0.05). Neutrophils and bacteria also exhibit directionality during migration in the infected mice. The semi-automated cell tracking protocol provides a streamlined approach to robustly identify and track individual cells across diverse experimental settings and eliminates inter-observer variability.

11.
J Bone Miner Res ; 37(4): 740-752, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35064941

RESUMEN

Individuals with type 2 diabetes mellitus (T2DM) have an increased risk of fragility fracture despite exhibiting normal to high bone mineral density (BMD). Conditions arising from T2DM, such as reduced bone turnover and alterations in microarchitecture, may contribute to skeletal fragility by influencing bone morphology and microdamage accumulation. The objectives of this study were (i) to characterize the effect of T2DM on microdamage quantity and morphology in cancellous bone, and (ii) relate the accumulation of microdamage to the cancellous microarchitecture. Cancellous specimens from the femoral neck were collected during total hip arthroplasty (T2DM: n = 22, age = 65 ± 9 years, glycated hemoglobin [HbA1c] = 7.00% ± 0.98%; non-diabetic [non-DM]: n = 25, age = 61 ± 8 years, HbA1c = 5.50% ± 0.4%), compressed to 3% strain, stained with lead uranyl acetate to isolate microdamage, and scanned with micro-computed tomography (µCT). Individual trabeculae segmentation was used to isolate rod-like and plate-like trabeculae and their orientations with respect to the loading axis. The T2DM group trended toward a greater BV/TV (+27%, p = 0.07) and had a more plate-like trabecular architecture (+8% BVplates , p = 0.046) versus non-DM specimens. Rods were more damaged relative to their volume compared to plates in the non-DM group (DVrods /BVrods versus DVplates /BVplates : +49%, p < 0.0001), but this difference was absent in T2DM specimens. Longitudinal rods were more damaged in the non-DM group (DVlongitudinal rods /BVlongitudinal rods : +73% non-DM versus T2DM, p = 0.027). Total damage accumulation (DV/BV) and morphology (DS/DV) did not differ in T2DM versus non-DM specimens. These results provide evidence that cancellous microarchitecture does not explain fracture risk in T2DM, pointing to alterations in material matrix properties. In particular, cancellous bone from men with T2DM may have an attenuated ability to mitigate microdamage accumulation through sacrificial rods. © 2022 American Society for Bone and Mineral Research (ASBMR).


Asunto(s)
Hueso Esponjoso , Diabetes Mellitus Tipo 2 , Anciano , Densidad Ósea , Hueso Esponjoso/diagnóstico por imagen , Diabetes Mellitus Tipo 2/complicaciones , Cuello Femoral/diagnóstico por imagen , Hemoglobina Glucada , Humanos , Masculino , Persona de Mediana Edad , Microtomografía por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA