Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Pediatr Surg Int ; 27(3): 295-301, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20697899

RESUMEN

PURPOSE: To study the effects of tezosentan, a dual ETA and ETB receptor antagonist on the cardiopulmonary profile in a fetal lamb model of CDH in utero. METHODS: A diaphragmatic hernia was surgically created at day 75 of gestation. During 45 min of tezosentan perfusion (1 mg/kg), hemodynamic parameters (pulmonary and aortic pressures, left pulmonary and aortic flows, left auricle pressure, heart rate) were measured at day 135 of gestation. Age-matched fetal lambs served as control animals. Secondarily, parietal tension of vessels rings of pulmonary arteries was assessed in organ baths under increasing concentration of tezosentan. RESULTS: In CDH group, under perfusion of tezosentan, pulmonary artery pressure decreased from 45.8 ± 4.1 to 37.6 ± 5.9 mmHg (P < 0.05). Pulmonary artery flow and pulmonary vascular resistance remained constant. In control group, pulmonary artery flow increased from 153.9 ± 15.8 to 233.4 ± 26 ml/min (P < 0.05). Pulmonary artery pressure did not vary. Subsequently calculated pulmonary vascular resistance decreased. In organ bath, no significant relaxation was observed. CONCLUSION: In this fetal lamb model of CDH, tezosentan decreased pulmonary artery pressure but did not modify pulmonary blood flow. Endothelin may play a role in the regulation of pulmonary vascular tone in utero.


Asunto(s)
Antagonistas de los Receptores de la Endotelina A , Antagonistas de los Receptores de la Endotelina B , Hipertensión Pulmonar/tratamiento farmacológico , Hipertensión Pulmonar/fisiopatología , Arteria Pulmonar/fisiopatología , Piridinas/farmacología , Tetrazoles/farmacología , Animales , Modelos Animales de Enfermedad , Femenino , Feto/fisiopatología , Hemodinámica , Hernia Diafragmática/fisiopatología , Hernias Diafragmáticas Congénitas , Embarazo , Ovinos , Estadísticas no Paramétricas
2.
Am J Physiol Heart Circ Physiol ; 295(6): H2231-41, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18820030

RESUMEN

Time-domain representations of the fetal aortopulmonary circulation were carried out in lamb fetuses to study hemodynamic consequences of congenital diaphragmatic hernia (CDH) and the effects of endothelin-receptor antagonist tezosentan (3 mg/45 min). From the isthmic aortic and left pulmonary artery (PA) flows (Q) and isthmic aortic, PA, and left auricle pressures (P) on day 135 in 10 controls and 7 CDH fetuses (28 ewes), discrete-triggered P and Q waveforms were modelized as Pt and Qt functions to obtain basic hemodynamic profiles, pulsatile waves [P, Q, and entry impedance (Ze)], and P and Q hysteresis loops. In the controls, blood propelling energy was accounted for by biventricular ejection flow waves (kinetic energy) with low Ze and by flow-driven pressure waves (potential energy) with low Ze. Weak fetal pulmonary perfusion was ensured by reflux (reverse flows) from PA branches to the ductus anteriosus and aortic isthmus as reverse flows. Endothelin-receptor antagonist blockade using tezosentan slightly increased the forward flow but largely increased diastolic backward flow with a diminished left auricle pre- and postloading. In CHD fetuses, the static component overrode phasic flows that were detrimental to reverse flows and the direction of the diastolic isthmic flow changed to forward during the diastole period. Decreased cardiac output, flattened pressure waves, and increased forward Ze promoted backward flow to the detriment of forward flow (especially during diastole). Additionally, the intrapulmonary arteriovenous shunting was ineffective. The slowing of cardiac output, the dampening of energetic pressure waves and pulsatility, and the heightening of phasic impedances contributed to the lowering of aortopulmonary blood flows. We speculate that reverse pulmonary flow is a physiological requirement to protect the fetal pulmonary circulation from the prominent right ventricular stream and to enhance blood flow to the fetal heart and brain.


Asunto(s)
Aorta/fisiopatología , Hemodinámica , Hernia Diafragmática/fisiopatología , Pulmón/irrigación sanguínea , Arteria Pulmonar/fisiopatología , Circulación Pulmonar , Animales , Aorta/efectos de los fármacos , Aorta/embriología , Presión Sanguínea , Gasto Cardíaco , Antagonistas de los Receptores de Endotelina , Feto/irrigación sanguínea , Edad Gestacional , Hemodinámica/efectos de los fármacos , Hernia Diafragmática/patología , Hernias Diafragmáticas Congénitas , Pulmón/embriología , Pulmón/ultraestructura , Microscopía Electrónica de Rastreo , Arteria Pulmonar/efectos de los fármacos , Arteria Pulmonar/embriología , Arteria Pulmonar/ultraestructura , Circulación Pulmonar/efectos de los fármacos , Flujo Pulsátil , Piridinas/farmacología , Flujo Sanguíneo Regional , Ovinos , Tetrazoles/farmacología , Factores de Tiempo , Vasoconstricción , Vasodilatadores/farmacología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA