RESUMEN
BACKGROUND: Vancomycin-resistant enterococci (VRE) are antibiotic-resistant organisms associated with both colonization and serious life-threatening infection in health care settings. Contamination of platelet concentrates (PCs) with Enterococcus can result in transfusion-transmitted infection. CASE PRESENTATION: This report describes the investigation of a septic transfusion case involving a 27-year-old male patient with relapsed acute leukemia who was transfused with a 5-day-old buffy coat PC pool and developed fever and rigors. DISCUSSION: Microbiology testing and pulse-field gel electrophoresis (PFGE) was done on patient blood cultures obtained from peripheral and central lines. Microbiology and molecular testing were also performed on the remaining posttransfusion PC pool, which was refrigerated for 24 hours before microbiology testing. Red blood cell (RBC) and plasma units associated with the implicated PCs were screened for microbial contamination. Patient blood cultures obtained from peripheral and central lines yielded vancomycin-resistant Enterococcus faecium. Gram stain of a sample from the platelet pool was negative but coagulase-negative Staphylococcus (CNST) and VRE were isolated on culture. Antibiotic sensitivity and PFGE profiles of several VRE isolates from the patient before and after transfusion, and the PC pool, revealed that all were closely related. Associated RBC and plasma components tested negative for microbial contamination. CONCLUSIONS: Microbiological and molecular investigations showed a relationship between VRE isolated from the patient before and after transfusion, and therefore it is postulated that a patient-to-PC retrograde contamination (from either blood or skin) occurred. As the CNST isolated from the PC pool was not isolated from patient samples, its implication in the transfusion event is unknown.