J Appl Clin Med Phys ; 14(4): 4133, 2013 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-23835379

RESUMEN

A frameless radiosurgery system is using a set of thermoplastic mask for fixation and stereoscopic X-ray imaging for alignment. The accuracy depends on mask fixation and imaging. Under certain circumstances, the guidance images may contain insufficient bony structures, resulting in lesser accuracy. A virtual isocenter function is designed for such scenarios. In this study, we investigated the immobilization and the indications for using virtual isocenter. Twenty-four arbitrary imaginary treatment targets (ITTs) in phantom were evaluated. The external Localizer with positioner films was used as reference. The alignments by using actual and virtual isocenter in image guidance were compared. The deviation of the alignment after mask removing and then resetting was also checked. The results illustrated that the mean deviation between the alignment by image guidance using actual isocenter (Iso(img)) and the localizer(Iso(loc)) was 2.26 mm ± 1.16 mm (standard deviation, SD), 1.66 mm ± 0.83 mm for using virtual isocenter. The deviation of the alignment by the image guidance using actual isocenter to the localizer before and after mask resetting was 7.02 mm ± 5.8 mm. The deviations before and after mask resetting were insignificant for the target center from skull edge larger than 80 mm on craniocaudal direction. The deviations between the alignment using actual and virtual isocenter in image guidance were not significant if the minimum distance from target center to skull edge was larger or equal to 30 mm. Due to an unacceptable deviation after mask resetting, the image guidance is necessary to improve the accuracy of frameless immobilization. A treatment isocenter less than 30 mm from the skull bone should be an indication for using virtual isocenter to align in image guidance. The virtual isocenter should be set as caudally as possible, and the sella of skull should be the ideal point.


Asunto(s)
Inmovilización/instrumentación , Posicionamiento del Paciente/instrumentación , Fantasmas de Imagen , Radiocirugia/instrumentación , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/cirugía , Humanos , Planificación de la Radioterapia Asistida por Computador , Tomografía Computarizada por Rayos X
2.
Front Oncol ; 8: 359, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30234018

RESUMEN

Introduction: Maintaining immobilization to minimize skull motion is important during frameless radiosurgery. This study aimed to compare the intrafractional skull motions between two head supports. Methods: With 6D skull tracking system, 4,075 image records from 45 patients receiving radiosurgery by CyberKnife were obtained. Twenty-three patients used TIMO head supports (CIVCO) (Group A) and twenty-two patients used Silverman head supports (CIVCO) with MoldCare cushions (ALCARE) (Group B). The skull motions in X (superior-inferior), Y (right-left), Z (anterior-posterior) axes, 3D (three-dimensional) vector, Roll, Pitch and Yaw between the two groups were compared and the margins of planning target volume were estimated. Results: The translational motions in Group A were similar in three axes at initial but became different after 10 min, and those in Group B were less prominent in the Y axis. The rotational errors in Group A were most obvious in Yaw, but those in Group B were stationary in three axes. The motions in the X axis, 3D vector, Pitch and Yaw in Group B were significantly smaller than those in Group A; conversely, the motions in the Z axis in Group B were larger. To cover the 95% confidence intervals, margins of 0.77, 0.79, and 0.40 mm in the X, Y, and Z axes, respectively, were needed in Group A, and 0.69, 0.50, and 0.51 mm were needed in Group B. Conclusions: Both head supports could provide good immobilization during the frameless radiosurgery. Silverman head support with MoldCare cushion was better than TIMO head support in the superior-inferior direction, 3D vector, Pitch and Yaw axes, but worse in the anterior-posterior direction.

3.
J Radiat Res ; 54(5): 909-18, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23536544

RESUMEN

To evaluate the effect of different treatment plans for whole-pelvic irradiation on small-bowel volumes (SBVs) in patients with gynecologic malignancies, 40 patients were enrolled in this study. Computed tomography (CT) simulations were performed, and the small bowel of each patient was outlined manually. Treatment plans with equal-weighted (EW) and non-equal-weighted (NEW) (70% in bilateral directions) techniques of four-field and intensity-modulated radiation therapy (IMRT) were performed. The V10-V100 represented the volume (cm³) at different levels of the prescribed doses (10-100%). The V10-V100 was compared among the different treatment planning techniques, and patients who were suitable for IMRT or NEW were identified. IMRT and NEW significantly reduced the V50-V100 and V40-V60 levels compared with EW, respectively. NEW caused a significant reduction in the V30-V60 levels in patients with a BMI ≥26 kg/m². Patients with IMRT demonstrated lower V70-V100 levels compared with those with NEW. In patients with a BMI ≥26 kg/m² or an age ≥55 years, lower V20-V50 levels were noted using NEW compared with IMRT. Treatment planning with larger weighting in the bilateral directions in four-field radiotherapy reduces the low-dose SBV in patients with gynecologic malignancies, especially in those with a high BMI or the elderly. IMRT effectively reduces high-dose SBV, especially in patients with a low BMI.


Asunto(s)
Neoplasias de los Genitales Femeninos/radioterapia , Intestino Delgado/efectos de la radiación , Órganos en Riesgo/efectos de la radiación , Dosis de Radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Conformacional/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Persona de Mediana Edad , Dosificación Radioterapéutica , Medición de Riesgo