Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Anal Bioanal Chem ; 416(23): 5025-5035, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39028344

RESUMEN

Free iron in human serum or non-transferrin-bound iron (NTBI) can generate free radicals and lead to oxidative damage. Moreover, it is highly toxic to various tissues and a vital biomarker related to the iron-loading status of thalassemia and Alzheimer's patients. In NTBI in healthy individuals, NTBI levels are typically less than 1 µM; current NTBI analysis usually requires advanced instrumentation and many-step sample pretreatment. To address this issue, we employed our invented BODIPY derivative, BODIPY-PH, as a fluorescence probe and trapped it onto the microcentrifuge tube lid using tapioca starch. The fluorescence intensity of BODIPY-PH increased with increasing NTBI concentration (turn-on). The developed portable reaction chamber facilitates rapid analysis (∼5 min) using small sample volumes (10 µL sample in a total volume of 600 µL). Under optimum conditions, using the sample-developed portable fluorescence device and fluorescence spectrometer, we achieved impressive limits of detection (LOD) of 0.003 and 0.0015 µM, respectively. Furthermore, the developed sensors show relatively high selectivity toward Fe3+ over other metal ions and biomolecules (i.e., Fe2+, Cr3+, Cu2+, and glucose). The sensor performance in serum samples of thalassemia patients exhibited no significant difference compared to the labeled value (obtained from standard methods). Overall, the developed fluorescence sensor is suitable for determining NTBI and offers high sensitivity, high selectivity, and a short incubation time (5 min). Moreover, the method requires a limited number of reagents, is simple to use, and uses low-cost equipment to determine NTBI in human serum samples.


Asunto(s)
Compuestos de Boro , Colorantes Fluorescentes , Hierro , Límite de Detección , Espectrometría de Fluorescencia , Humanos , Hierro/sangre , Compuestos de Boro/química , Espectrometría de Fluorescencia/métodos , Colorantes Fluorescentes/química , Hidrazonas/química , Transferrina/análisis
2.
Sensors (Basel) ; 23(7)2023 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-37050585

RESUMEN

Staphylococcus epidermidis (S. epidermidis) belongs to methicillin-resistant bacteria strains that cause severe disease in humans. Herein, molecularly imprinted polymer (MIP) nanoparticles resulting from solid-phase synthesis on entire cells were employed as a sensing material to identify the species. MIP nanoparticles revealed spherical shapes with diameters of approximately 70 nm to 200 nm in scanning electron microscopy (SEM), which atomic force microscopy (AFM) confirmed. The interaction between nanoparticles and bacteria was assessed using height image analysis in AFM. Selective binding between MIP nanoparticles and S. epidermidis leads to uneven surfaces on bacteria. The surface roughness of S. epidermidis cells was increased to approximately 6.3 ± 1.2 nm after binding to MIP nanoparticles from around 1 nm in the case of native cells. This binding behavior is selective: when exposing Escherichia coli and Bacillus subtilis to the same MIP nanoparticle solutions, one cannot observe binding. Fluorescence microscopy confirms both sensitivity and selectivity. Hence, the developed MIP nanoparticles are a promising approach to identify (pathogenic) bacteria species.


Asunto(s)
Impresión Molecular , Nanopartículas , Humanos , Polímeros/química , Impresión Molecular/métodos , Nanopartículas/química , Polímeros Impresos Molecularmente , Microscopía de Fuerza Atómica
3.
Anal Chem ; 94(48): 16692-16700, 2022 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-36409323

RESUMEN

Nanoscale imprinting significantly increases the specific surface area and recognition capabilities of a molecularly imprinted polymer by improving accessibility to analytes, binding kinetics, and template removal. Herein, we present a novel synthetic route for a dual molecularly imprinted polymer (dual-MIP) of the carcinogen oxidative stress biomarkers 3-nitrotyrosine (3-NT) and 4-nitroquinolin-N-oxide (4-NQO) as coatings on graphene quantum-dot capped gold nanoparticles (GQDs-AuNPs). The dual-MIP was successfully coated on the GQDs-AuNPs core via a (3-mercaptopropyl) trimethoxysilane (MPTMS) linkage and copolymerization with the 3-aminopropyltriethoxysilane (APTMS) functional monomer. In addition, we fabricated a facile and compact three-dimensional electrochemical paper-based analytical device (3D-ePAD) for the simultaneous determination of the dual biomarkers using a GQDs-AuNPs@dual-MIP-modified graphene electrode (GQDs-AuNPs@dual-MIP/SPGE). The developed dual-MIP device provides greatly enhanced electrochemical signal amplification due to the improved electrode-specific surface area, electrocatalytic activity, and the inclusion of large numbers of dual-imprinted sites for 3-NT and 4-NQO detection. Quantitative analysis used square wave voltammetry, with an oxidation current appearing at -0.10 V for 4-NQO and +0.78 V for 3-NT. The dual-MIP sensor revealed excellent linear dynamic ranges of 0.01 to 500 µM for 3-NT and 0.005 to 250 µM for 4-NQO, with detection limits in nanomolar levels for both biomarkers. Furthermore, the dual-MIP sensor for the simultaneous determination of 3-NT and 4-NQO provides high accuracy and precision, with no evidence of interference from urine, serum, or whole blood samples.


Asunto(s)
Grafito , Nanopartículas del Metal , Impresión Molecular , Oro , Polímeros Impresos Molecularmente , Impresión Molecular/métodos , Técnicas Electroquímicas/métodos , Carcinógenos , Límite de Detección , Electrodos , Biomarcadores , Estrés Oxidativo , Pruebas en el Punto de Atención
4.
Soft Matter ; 18(11): 2245-2251, 2022 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-35234796

RESUMEN

Investigations on lithographically formed cavities of surface-imprinted polymers (SIP) can help to gain deeper understanding on cell recognition with SIPs: it is known that surface topography and biomolecules transferred during surface imprinting contribute to cell adhesion. In this work, SIPs synthesized via two different imprinting techniques, namely stamp imprinting and polymerization of Pickering emulsions, were investigated and compared to each other, using atomic force microscopy (AFM) and Peak Force Quantitative Nano Mechanics (PF-QNM). We focused on SIPs based on poly(styrene-co-divinylbenzene) as model polymer and E. coli as model template for cell imprinting. Both imprinting approaches led to cavities that revealed nanostructures within the imprints. Stamp imprinting cavities feature low surface roughness and channel structures that resemble the negative pattern of the bacteria on the stamp and their filaments, while SIPs synthesized via polymerization of Pickering emulsions reveal globular nanostructures accumulating in the imprints. AFM phase imaging and adhesion mapping using PF-QNM show that these globular structures are remainders of the imprinted E. coli cells, most likely lipopolysaccarides, which is not observable in imprints resulting from stamp imprinting.


Asunto(s)
Impresión Molecular , Polímeros , Escherichia coli , Microscopía de Fuerza Atómica , Impresión Molecular/métodos , Polimerizacion , Polímeros/química
5.
Anal Bioanal Chem ; 414(1): 731-741, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34950982

RESUMEN

Solid-phase synthesis is an elegant way to create molecularly imprinted polymer nanoparticles (nano-MIPs) comprising a single binding site, i.e. mimics of antibodies. When using human serum albumin (HSA) as the template, one achieves nano-MIPs with 53 ± 19 nm diameter, while non-imprinted polymer nanoparticles (nano-NIPs) reach 191 ± 96 nm. Fluorescence assays lead to Stern-Volmer plots revealing selective binding to HSA with selectivity factors of 1.2 compared to bovine serum albumin (BSA), 1.9 for lysozyme, and 4.1 for pepsin. Direct quartz crystal microbalance (QCM) assays confirm these results: nano-MIPs bind to HSA immobilized on QCM surfaces. This opens the way for competitive QCM-based assays for HSA: adding HSA to nanoparticle solutions indeed reduces binding to the QCM surfaces in a concentration-dependent manner. They achieve a limit of detection (LoD) of 80 nM and a limit of quantification (LoQ) of 244 nM. Furthermore, the assay shows recovery rates around 100% for HSA even in the presence of competing analytes.


Asunto(s)
Impresión Molecular , Tecnicas de Microbalanza del Cristal de Cuarzo , Humanos , Límite de Detección , Polímeros/química , Albúmina Sérica Humana
6.
Anal Bioanal Chem ; 413(24): 6191-6198, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34091710

RESUMEN

Graphene oxide-molecularly imprinted polymer composites (GO-MIP) have attracted significant attention as recognition materials in sensing due to their outstanding properties in terms of electrical and thermal conductivity, high mechanical modulus, and the comparably straightforward way to functionalize them. The aim of this study was to design a MIP-based sensor recognition material and enhance its sensitivity by blending it with GO for sensing a harmful dengue hemorrhagic fever pathogen, namely the dengue type 1 virus (DENV-1). Polymer composites comprising GO incorporated to an acrylamide (AAM)/methacrylic acid (MAA)/methyl methacrylate (MMA)/N-vinylpyrrolidone (VP) copolymer were synthesized and compared to the "pure" MIP, i.e., the copolymer without GO. The pure polymer revealed a zeta potential of + 9.9 ± 0.5 mV, whereas GO sheets prepared have a zeta potential of - 60.3 ± 2.7 mV. This results in an overall zeta potential of - 11.2 ± 0.2 mV of the composite. Such polymer composites seem appropriate to bind the positively charged DENV-1 particle (+ 42.2 ± 2.8 mV). GO-MIP coated onto 10-MHz quartz crystal microbalance (QCM) sensors indeed revealed two times sensitivity compared to sensors based on the pure MIP. Furthermore, GO-polymer composites revealed imprinting factors of up to 21, compared to 3 of the pure MIP. When plotting the sensor characteristic in a semilogarithmic way, the composite sensor shows the linear response to DENV-1 in the concentration range from 100 to 103 pfu mL-1. The corresponding limits of detection (S/N = 3) and quantification (S/N = 10) are 0.58 and 1.94 pfu mL-1, respectively. Furthermore, imprinted polymer composites selectively bind DENV-1 without significant interference: DENV-2, DENV-3, DENV-4, respectively, yield 13-16% of DENV-1 signal. The sensor requires only about 15-20 min to obtain a result.


Asunto(s)
Virus del Dengue/aislamiento & purificación , Grafito/química , Polímeros/química , Tecnicas de Microbalanza del Cristal de Cuarzo , Virus del Dengue/ultraestructura , Límite de Detección , Microscopía Electrónica de Rastreo , Propiedades de Superficie
7.
Sensors (Basel) ; 21(16)2021 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-34450992

RESUMEN

Molecularly imprinted polymers (MIPs) come with the promise to be highly versatile, useful artificial receptors for sensing a wide variety of analytes. Despite a very large body of literature on imprinting, the number of papers addressing real-life biological samples and analytes is somewhat limited. Furthermore, the topic of MIP-based sensor design is still, rather, in the research stage and lacks wide-spread commercialization. This review summarizes recent advances of MIP-based sensors targeting biological species. It covers systems that are potentially interesting in medical applications/diagnostics, in detecting illicit substances, environmental analysis, and in the quality control of food. The main emphasis is placed on work that demonstrates application in real-life matrices, including those that are diluted in a reasonable manner. Hence, it does not restrict itself to the transducer type, but focusses on both materials and analytical tasks.


Asunto(s)
Impresión Molecular , Biomimética , Polímeros Impresos Molecularmente , Polímeros
8.
Sensors (Basel) ; 20(12)2020 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-32560552

RESUMEN

Water quality is one of the most critical indicators of environmental pollution and it affects all of us. Water contamination can be accidental or intentional and the consequences are drastic unless the appropriate measures are adopted on the spot. This review provides a critical assessment of the applicability of various technologies for real-time water quality monitoring, focusing on those that have been reportedly tested in real-life scenarios. Specifically, the performance of sensors based on molecularly imprinted polymers is evaluated in detail, also giving insights into their principle of operation, stability in real on-site applications and mass production options. Such characteristics as sensing range and limit of detection are given for the most promising systems, that were verified outside of laboratory conditions. Then, novel trends of using microwave spectroscopy and chemical materials integration for achieving a higher sensitivity to and selectivity of pollutants in water are described.

9.
Sensors (Basel) ; 19(10)2019 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-31126005

RESUMEN

Food standards and quality control are important means to ensure public health. In the last decade, melamine has become a rather notorious example of food adulteration: Spiking products with low-cost melamine in order to feign high amino acid content exploits the lack in specificity of the established Kjeldahl method for determining organic nitrogen. This work discusses the responses of a sensor based on quartz crystal microbalances (QCM) coated with molecularly imprinted polymers (MIP) to detect melamine in real life matrices both in a selective and a sensitive manner. Experiments in pure milk revealed no significant sensor responses. However, sensor response increased to a frequency change of -30Hz after diluting the matrix ten times. Systematic evaluation of this effect by experiments in melamine solutions containing bovine serum albumin (BSA) and casein revealed that proteins noticeably influence sensor results. The signal of melamine in water (1600 mg/L) decreases to half of its initial value, if either 1% BSA or casein are present. Higher protein concentrations decrease sensor responses even further. This suggests significant interaction between the analyte and proteins in general. Follow-up experiments revealed that centrifugation of tagged serum samples results in a significant loss of sensor response, thereby further confirming the suspected interaction between protein and melamine.


Asunto(s)
Leche/química , Impresión Molecular/métodos , Polímeros/química , Triazinas/análisis , Animales , Caseínas/química , Bovinos , Tecnicas de Microbalanza del Cristal de Cuarzo , Albúmina Sérica Bovina/química , Triazinas/química
10.
Anal Bioanal Chem ; 410(3): 875-883, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28664338

RESUMEN

Decreased blood level of high-density lipoprotein (HDL) is one of the essential criteria in diagnosing metabolic syndrome associated with the development of atherosclerosis and coronary heart disease. Herein, we report the synthesis of a molecularly imprinted polymer (MIP) that selectively binds HDL, namely, HDL-MIP, and thus serves as an artificial, biomimetic sensor layer. The optimized polymer contains methacrylic acid and N-vinylpyrrolidone in the ratio of 2:3, cross-linked with ethylene glycol dimethacrylate. On 10 MHz dual electrode quartz crystal microbalances (QCM), such HDL-MIP revealed dynamic detection range toward HDL standards in the clinically relevant ranges of 2-250 mg/dL HDL cholesterol (HDL-C) in 10 mM phosphate-buffered saline (PBS, pH = 7.4) without significant interference: low-density lipoprotein (LDL) yields 5% of the HDL signal, and both very-low-density lipoprotein (VLDL) and human serum albumin (HSA) yield 0%. The sensor reveals recovery rates between 94 and 104% at 95% confidence interval with precision of 2.3-7.7% and shows appreciable correlation (R 2 = 0.97) with enzymatic colorimetric assay, the standard in clinical tests. In contrast to the latter, it achieves rapid results (10 min) during one-step analysis without the need for sample preparation. Graphical Abstract ᅟ.


Asunto(s)
Lipoproteínas HDL/sangre , Metacrilatos/química , Impresión Molecular/métodos , Pirrolidinonas/química , Tecnicas de Microbalanza del Cristal de Cuarzo/métodos , Técnicas Biosensibles/métodos , Humanos , Límite de Detección , Lipoproteínas LDL/sangre , Reproducibilidad de los Resultados
11.
Sensors (Basel) ; 18(1)2018 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-29320454

RESUMEN

Herein we report novel approaches to the molecular imprinting of proteins utilizing templates sizing around 10 nm and some 100 nm. The first step comprised synthesizing nanoparticles of molecularly imprinted polymers (MIP) towards bovine serum albumin (BSA) and characterizing them according to size and binding capacity. In a second step, they were utilized as templates. Quartz crystal microbalances (QCM) coated with MIP thin films based on BSA MIP nanoparticles lead to a two-fold increase in sensor responses, compared with the case of directly using the protein as the template. This also established that individual BSA molecules exhibit different "epitopes" for molecular imprinting on their outer surfaces. In light of this knowledge, a possible MIP-based biomimetic assay format was tested by exposing QCM coated with BSA MIP thin films to mixtures of BSA and imprinted and non-imprinted polymer (NIP) nanoparticles. At high protein concentrations (1000 ppm) measurements revealed aggregation behavior, i.e., BSA binding MIP NP onto the MIP surface. This increased sensor responses by more than 30% during proof of concept measurements. At lower a BSA concentration (500 ppm), thin films and particles revealed competitive behavior.


Asunto(s)
Impresión Molecular , Nanopartículas , Polímeros , Tecnicas de Microbalanza del Cristal de Cuarzo , Albúmina Sérica Bovina
12.
Nanomedicine ; 13(2): 549-557, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27558351

RESUMEN

Dengue fever is a major disease that kills many people in the developing world every year. During early infection, a patient displays a high temperature without other signs. After this stage, and without proper treatment, serious damage to internal organs can happen, which occasionally leads to death. A rapid technique for the early detection of dengue virus (DENV) could reduce the number of fatalities. This study presents a new technique for the detection, classification and antibody screening of DENV based on electrochemical impedance spectroscopy (EIS). We found that the charge transfer resistance (Rct) of a gold electrode coated with graphene oxide reinforced polymer was influenced by virus type and quantity exposed on the surface. Molecular recognition capability established during the GO-polymer composite preparation was used to explain this observation. The linear dependence of Rct versus virus concentrations ranged from 1 to 2×103pfu/mL DENV with a 0.12 pfu/mL detection limit.


Asunto(s)
Técnicas Biosensibles , Virus del Dengue/inmunología , Dengue/diagnóstico , Técnicas Electroquímicas , Electrodos , Oro , Grafito , Humanos , Polímeros
13.
Anal Chem ; 88(2): 1419-25, 2016 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-26643785

RESUMEN

Increased level of low-density lipoprotein (LDL) strongly correlates with incidence of coronary heart disease. We synthesized novel molecularly imprinted polymers (MIP) as biomimetic specific receptors to establish rapid analysis of LDL levels. For that purpose the ratios of monomers acrylic acid (AA), methacrylic acid (MAA), and N-vinylpyrrolidone (VP), respectively, were screened on 10 MHz dual-electrode quartz crystal microbalances (QCM). Mixing MAA and VP in the ratio 3:2 (m/m) revealed linear sensor characteristic to LDL cholesterol (LDL-C) from 4 to 400 mg/dL or 0.10-10.34 mmol/L in 100 mM phosphate-buffered saline (PBS) without significant interference: high-density lipoprotein (HDL) yields 4-6% of the LDL signal, very-low-density-lipoprotein (VLDL) yields 1-3%, and human serum albumin (HSA) yields 0-2%. The LDL-MIP sensor reveals analytical accuracy of 95-96% at the 95% confidence interval with precision at 6-15%, respectively. Human serum diluted 1:2 with PBS buffer was analyzed by LDL-MIP sensors to demonstrate applicability to real-life samples. The sensor responses are excellently correlated to the results of the standard technique, namely, a homogeneous enzymatic assay (R(2) = 0.97). This demonstrates that the system can be successfully applied to human serum samples for determining LDL concentrations.


Asunto(s)
Dimetilpolisiloxanos/química , Lipoproteínas LDL/sangre , Impresión Molecular , Electrodos , Humanos , Lipoproteínas LDL/síntesis química , Lipoproteínas LDL/química , Albúmina Sérica/química
14.
J Sep Sci ; 39(4): 793-8, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26632078

RESUMEN

In the present work, novel molecularly imprinted polymer porous beads for the selective separation of copper ions have been synthesized by combining two material-structuring techniques, namely, molecular imprinting and oil-in-water-in-oil emulsion polymerization. This method produces monodisperse spherical beads with an average diameter of ∼2-3 mm, in contrast to adsorbents produced in the traditional way of grinding and sieving. Field-emission scanning electron microscopy indicates that the beads are porous in nature with interconnected pores of about 25-50 µm. Brunner-Emmett-Teller analysis shows that the ion-imprinted beads possess a high surface area (8.05 m(2) /g), and the total pore volume is determined to be 0.00823 cm(3) /g. As a result of the highly porous nature and ion-imprinting, the beads exhibit a superior adsorption capacity (84 mg/g) towards copper than the non-imprinted material (22 mg/g). Furthermore, selectivity studies indicate that imprinted beads show splendid recognizing ability, that is, nearly fourfold greater selective binding for Cu(2+) in comparison to the other bivalent ions such as Mn(2+) , Ni(2+) , Co(2+) , and Ca(2+) . The imprinted composite beads prepared in this study possess uniform porous morphology and may open up new possibilities for the selective removal of copper ions from waste water/contaminated matrices.

15.
Sensors (Basel) ; 16(7)2016 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-27376287

RESUMEN

Herein, we report on molecularly imprinted polymers (MIPs) for detecting formaldehyde vapors in air streams. A copolymer thin film consisting of styrene, methacrylic acid, and ethylene glycol dimethacrylate on quartz crystal microbalance (QCM) yielded a detection limit of 500 ppb formaldehyde in dry air. Surprisingly, these MIPs showed specific behavior when tested against a range of volatile organic compounds (VOCs), such as acetaldehyde, methanol, formic acid, and dichloromethane. Despite thus being a suitable receptor in principle, the MIPs were not useful for measurements at 50% humidity due to surface saturation by water. This was overcome by introducing primary amino groups into the polymer via allyl amine and by changing the coating morphology from thin film to nanoparticles. This led to the same limit of detection (500 ppb) and selectivity as before, but at the real-life conditions of 50% relative humidity.

16.
Anal Chem ; 86(3): 1679-86, 2014 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-24392724

RESUMEN

A complex prepolymerized film comprising monomers, cross-linkers, and initiator is usually used to create molecularly imprinted polymers. We herein exploit ready-to-use resist materials and link molecular surface imprinting with UV- and thermo-nanoimprinting techniques to create a sensor layer for the specific recognition of the bacterial surface markers lipopolysaccharide (LPS) and lipoteichoic acid (LTA). To account for the highly polar moieties of LPS and LTA, we evaluate different resist and stamp materials of distinct surface properties by AFM and molecularly imprinted sorbent assays. Thermo nanoimprinting of LPS and LTA micelles to Epon 1002F films exhibits excellent sensitivity of up to 13 times increased signals compared to those of the nonimprinted films and negligible cross-reaction with the tested nonspecific analyte. Additionally, the sensitivity and selectivity of the thermo nanoimprints is compared to conventional molecular surface imprints using a cocktail of acrylic monomers in QCM measurements.


Asunto(s)
Técnicas Biosensibles/métodos , Inmunoensayo/métodos , Lipopolisacáridos/análisis , Impresión Molecular , Nanotecnología/métodos , Ácidos Teicoicos/análisis , Temperatura , Materiales Biomiméticos/química , Lipopolisacáridos/química , Micelas , Sondas Moleculares/química , Polímeros/química , Propiedades de Superficie , Ácidos Teicoicos/química
17.
Talanta ; 269: 125512, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38091737

RESUMEN

Measuring the levels of the biomarkers vanillylmandelic acid (VMA) and 5-Hydroxyindole-3-acetic acid (5-HIAA) is a valuable tool for clinical diagnosis not only of neuroblastoma or carcinoid syndrome, but also of essential hypertension, depression, migraine, and Tourette's syndrome. Herein, we explore using graphene quantum dots (GQDs) coated with molecularly imprinted polymer (MIP) as novel dual-imprinted sensors for selective and simultaneous determination of VMA and 5-HIAA in urine and plasma samples. The dual-MIP was successfully coated on the GQDs core via co-polymerization of (3-aminopropyl) triethoxysilane (APTES) and tetraethyl orthosilicate (TEOS), acting as functional and cross-linking monomers, respectively. In addition, we successfully created the dual imprinted VMA and 5-HIAA shell on the GQDs' core via a one-pot synthesis. We fabricated a facile and ready-to-use Origami three-dimensional electrochemical paper-based analytical device (Origami 3D-ePAD) for simultaneous determination of VMA and 5-HIAA using a GQDs@dual-MIP modified graphene electrode (GQDs@dual-MIP/SPGE). The Origami 3D-ePAD was designed to form a voltammetric cell on a three-layer foldable sheet with several advantages. For example, they were quickly assembled and enhanced the device's physical durability with the hydrophobic backup sheet. The developed dual imprinted Origami 3D-ePAD leads to substantially enhanced sensitivity and selectivity to electrochemical signal amplification generated from increasing the electrode-specific surface area, electrocatalytic activity, and the large numbers of dual imprinted sites for VMA and 5-HIAA detection. The synthetic recognition sites are highly selective for 5-HIAA and VMA molecules with an imprinting factor of 8.46 and 7.10, respectively. Quantitative analysis relying on square wave voltammetry reveals excellent linear dynamic ranges of around 0.001-25 µM, with detection limits of 0.023 nM for 5-HIAA and 0.047 nM for VMA (3Sb, n = 3). The Origami 3D-ePAD provides high accuracy and precision (i.e., recovery values of 5-HIAA ranged from 82.98 to 98.40 %, and VMA ranged from 83.28 to 104.39 %), and RSD less than 4.37 %) in urine and plasma samples without any evidence of interference. Hence, it is well suited as a facile and ready-to-use disposable device for point-of-care testing. It is straightforward, cost-effective, reproducible, and stable. Furthermore, it allows for rapid analysis (analysis time ∼20s) useful in medical diagnosis and other relevant fields.


Asunto(s)
Tumor Carcinoide , Grafito , Impresión Molecular , Puntos Cuánticos , Humanos , Puntos Cuánticos/química , Polímeros Impresos Molecularmente , Grafito/química , Ácido Vanilmandélico , Biomarcadores de Tumor , Límite de Detección , Ácido Hidroxiindolacético , Acetatos , Impresión Molecular/métodos , Técnicas Electroquímicas/métodos
18.
Comput Biol Med ; 180: 108994, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39121680

RESUMEN

Oxidized low-density lipoprotein (oxLDL) induces the formation of atherosclerotic plaques. Apolipoprotein B100 (apoB100) is a crucial protein component in low-density lipoprotein (LDL), which includes oxLDL. The oxidation of amino acids and subsequent alterations in their structure generate oxLDL, which is a significant biomarker for the initial phases of coronary artery disease. This study employed molecular docking and molecular dynamics utilizing the MM/GBSA method to identify aptamers with a strong affinity for oxidized apoB100. Molecular docking and molecular dynamics were performed on two sequences of the aptamer candidates (aptamer no.11 (AP11: 5'-CTTCGATGTAGTTTTTGTATGGGGTGCCCTGGTTCCTGCA-3') and aptamer no.26 (AP26: 5'-GCGAACTCGCGAATCCAGAACGGGCTCGGTCCCGGGTCGA-3')), yielding respective binding free energies of -149.08 kcal/mol and -139.86 kcal/mol. Interaction modeling of the simulation revealed a strong hydrogen bond between the AP11-oxidized apoB100 complexes. In an aptamer-based gold nanoparticle (AuNP) aggregation assay, AP11 exhibits a color shift from red to purple with the highest absorbance ratio, and shows strong binding affinity to oxLDL, correlating with the simulation model results. AP11 demonstrated the potential for application as a novel recognition element in diagnostic methodologies and may also contribute to future advancements in preventive therapies for coronary artery disease.


Asunto(s)
Apolipoproteína B-100 , Aptámeros de Nucleótidos , Lipoproteínas LDL , Simulación del Acoplamiento Molecular , Simulación de Dinámica Molecular , Lipoproteínas LDL/química , Lipoproteínas LDL/metabolismo , Aptámeros de Nucleótidos/química , Aptámeros de Nucleótidos/metabolismo , Apolipoproteína B-100/química , Apolipoproteína B-100/metabolismo , Humanos , Oro/química , Nanopartículas del Metal/química
20.
ACS Sens ; 9(8): 3967-3978, 2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39079008

RESUMEN

This article reports on a bioanalytical sensor device that hosts three different transducer principles: impedance spectroscopy, quartz-crystal microbalance with dissipation monitoring, and the thermal-current-based heat-transfer method. These principles utilize a single chip, allowing one to perform either microbalance and heat transfer measurements in parallel or heat transfer and impedance measurements. When taking specific precautions, the three measurement modalities can even be used truly simultaneously. The probed parameters are distinctly different, so that one may speak about multiparametric or "orthogonal" sensing without crosstalk between the sensing circuits. Hence, this sensor allows one to identify which of these label-free sensing principles performs best for a given bioanalytical application in terms of a high signal amplitude and signal-to-noise ratio. As a proof-of-concept, the three-parameter sensor was validated by studying the spontaneous, collective detachment of eukaryotic cells in the presence of a temperature gradient between the QCM chip and the supernatant liquid. In addition to heat transfer, detachment can also be monitored by the impedance- and QCM-related signals. These features allow for the distinguishing between different yeast strains that differ in their flocculation genes, and the sensor device enables proliferation monitoring of yeast colonies over time.


Asunto(s)
Técnicas Biosensibles , Tecnicas de Microbalanza del Cristal de Cuarzo , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Tecnicas de Microbalanza del Cristal de Cuarzo/métodos , Temperatura , Espectroscopía Dieléctrica/métodos , Diseño de Equipo , Saccharomyces cerevisiae , Adhesión Celular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA