Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
J Magn Reson Imaging ; 59(4): 1242-1255, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37452574

RESUMEN

BACKGROUND: Increased afterload in aortic stenosis (AS) induces left ventricle (LV) remodeling to preserve a normal ejection fraction. This compensatory response can become maladaptive and manifest with motion abnormality. It is a clinical challenge to identify contractile and relaxation dysfunction during early subclinical stage to prevent irreversible deterioration. PURPOSE: To evaluate the changes of regional wall dynamics in 3D + time domain as remodeling progresses in AS. STUDY TYPE: Retrospective. POPULATION: A total of 31 AS patients with reduced and preserved ejection fraction (14 AS_rEF: 7 male, 66.5 [7.8] years old; 17 AS_pEF: 12 male, 67.0 [6.0] years old) and 15 healthy (6 male, 61.0 [7.0] years old). FIELD STRENGTH/SEQUENCE: 1.5 T Magnetic resonance imaging/steady state free precession and late-gadolinium enhancement sequences. ASSESSMENT: Individual LV models were reconstructed in 3D + time domain and motion metrics including wall thickening (TI), dyssynchrony index (DI), contraction rate (CR), and relaxation rate (RR) were automatically extracted and associated with the presence of scarring and remodeling. STATISTICAL TESTS: Shapiro-Wilk: data normality; Kruskal-Wallis: significant difference (P < 0.05); ICC and CV: variability; Mann-Whitney: effect size. RESULTS: AS_rEF group shows distinct deterioration of cardiac motions compared to AS_pEF and healthy groups (TIAS_rEF : 0.92 [0.85] mm, TIAS_pEF : 5.13 [1.99] mm, TIhealthy : 3.61 [1.09] mm, ES: 0.48-0.83; DIAS_rEF : 17.11 [7.89]%, DIAS_pEF : 6.39 [4.04]%, DIhealthy : 5.71 [1.87]%, ES: 0.32-0.85; CRAS_rEF : 8.69 [6.11] mm/second, CRAS_pEF : 16.48 [6.70] mm/second, CRhealthy : 10.82 [4.57] mm/second, ES: 0.29-0.60; RRAS_rEF : 8.45 [4.84] mm/second; RRAS_pEF : 13.49 [8.56] mm/second, RRhealthy : 9.31 [2.48] mm/second, ES: 0.14-0.43). The difference in the motion metrics between healthy and AS_pEF groups were insignificant (P-value = 0.16-0.72). AS_rEF group was dominated by eccentric hypertrophy (47.1%) with concomitant scarring. Conversely, AS_pEF group was dominated by concentric remodeling and hypertrophy (71.4%), which could demonstrate hyperkinesia with slight wall dyssynchrony than healthy. Dysfunction of LV mechanics corresponded to the presence of myocardial scarring (54.9% in AS), which reverted the compensatory mechanisms initiated and performed by LV remodeling. DATA CONCLUSION: The proposed 3D + time modeling technique may distinguish regional motion abnormalities between AS_pEF, AS_rEF, and healthy cohorts, aiding clinical diagnosis and monitoring of AS progression. Subclinical myocardial dysfunction is evident in early AS despite of normal EF. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY: Stage 1.


Asunto(s)
Estenosis de la Válvula Aórtica , Medios de Contraste , Humanos , Masculino , Niño , Estudios Retrospectivos , Cicatriz , Gadolinio , Imagen por Resonancia Magnética , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Hipertrofia , Función Ventricular Izquierda , Volumen Sistólico , Remodelación Ventricular
2.
Biomed Eng Online ; 23(1): 24, 2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38388416

RESUMEN

Aortic stenosis, hypertension, and left ventricular hypertrophy often coexist in the elderly, causing a detrimental mismatch in coupling between the heart and vasculature known as ventricular-vascular (VA) coupling. Impaired left VA coupling, a critical aspect of cardiovascular dysfunction in aging and disease, poses significant challenges for optimal cardiovascular performance. This systematic review aims to assess the impact of simulating and studying this coupling through computational models. By conducting a comprehensive analysis of 34 relevant articles obtained from esteemed databases such as Web of Science, Scopus, and PubMed until July 14, 2022, we explore various modeling techniques and simulation approaches employed to unravel the complex mechanisms underlying this impairment. Our review highlights the essential role of computational models in providing detailed insights beyond clinical observations, enabling a deeper understanding of the cardiovascular system. By elucidating the existing models of the heart (3D, 2D, and 0D), cardiac valves, and blood vessels (3D, 1D, and 0D), as well as discussing mechanical boundary conditions, model parameterization and validation, coupling approaches, computer resources and diverse applications, we establish a comprehensive overview of the field. The descriptions as well as the pros and cons on the choices of different dimensionality in heart, valve, and circulation are provided. Crucially, we emphasize the significance of evaluating heart-vessel interaction in pathological conditions and propose future research directions, such as the development of fully coupled personalized multidimensional models, integration of deep learning techniques, and comprehensive assessment of confounding effects on biomarkers.


Asunto(s)
Corazón , Función Ventricular Izquierda , Anciano , Humanos , Envejecimiento , Vasos Coronarios , Ventrículos Cardíacos
3.
Biomed Eng Online ; 23(1): 23, 2024 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-38378540

RESUMEN

PURPOSE: Non-invasive, beat-to-beat variations in physiological indices provide an opportunity for more accessible assessment of autonomic dysfunction. The potential association between the changes in these parameters and arterial stiffness in hypertension remains poorly understood. This systematic review aims to investigate the association between non-invasive indicators of autonomic function based on beat-to-beat cardiovascular signals with arterial stiffness in individuals with hypertension. METHODS: Four electronic databases were searched from inception to June 2022. Studies that investigated non-invasive parameters of arterial stiffness and autonomic function using beat-to-beat cardiovascular signals over a period of > 5min were included. Study quality was assessed using the STROBE criteria. Two authors screened the titles, abstracts, and full texts independently. RESULTS: Nineteen studies met the inclusion criteria. A comprehensive overview of experimental design for assessing autonomic function in terms of baroreflex sensitivity and beat-to-beat cardiovascular variabilities, as well as arterial stiffness, was presented. Alterations in non-invasive indicators of autonomic function, which included baroreflex sensitivity, beat-to-beat cardiovascular variabilities and hemodynamic changes in response to autonomic challenges, as well as arterial stiffness, were identified in individuals with hypertension. A mixed result was found in terms of the association between non-invasive quantitative autonomic indices and arterial stiffness in hypertensive individuals. Nine out of 12 studies which quantified baroreflex sensitivity revealed a significant association with arterial stiffness parameters. Three studies estimated beat-to-beat heart rate variability and only one study reported a significant relationship with arterial stiffness indices. Three out of five studies which studied beat-to-beat blood pressure variability showed a significant association with arterial structural changes. One study revealed that hemodynamic changes in response to autonomic challenges were significantly correlated with arterial stiffness parameters. CONCLUSIONS: The current review demonstrated alteration in autonomic function, which encompasses both the sympathetic and parasympathetic modulation of sinus node function and vasomotor tone (derived from beat-to-beat cardiovascular signals) in hypertension, and a significant association between some of these parameters with arterial stiffness. By employing non-invasive measurements to monitor changes in autonomic function and arterial remodeling in individuals with hypertension, we would be able to enhance our ability to identify individuals at high risk of cardiovascular disease. Understanding the intricate relationships among these cardiovascular variability measures and arterial stiffness could contribute toward better individualized treatment for hypertension in the future. SYSTEMATIC REVIEW REGISTRATION: PROSPERO ID: CRD42022336703. Date of registration: 12/06/2022.

4.
Biomed Eng Online ; 21(1): 19, 2022 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-35313918

RESUMEN

BACKGROUND: Mental illness represents a major global burden of disease worldwide. It has been hypothesised that individuals with mental illness have greater blood pressure fluctuations that lead to increased cardiovascular risk and target organ damage. This systematic review aims to (i) investigate the association between mental illness and blood pressure variability (BPV) and (ii) describe methods of BPV measurements and analysis which may affect pattern and degree of variability. METHODS: Four electronic databases were searched from inception until 2020. The quality assessment was performed using STROBE criteria. Studies were included if they investigated BPV (including either frequency or time domain analysis) in individuals with mental illness (particularly anxiety/generalised anxiety disorder, depression/major depressive disorder, panic disorder and hostility) and without hypertension. Two authors independently screened titles, abstracts and full texts. A third author resolved any disagreements. RESULTS: Twelve studies met the inclusion criteria. Three studies measured short-term BPV, two measured long-term BPV and seven measured ultra-short-term BPV. All studies related to short-term BPV using ambulatory and home blood pressure monitoring found a higher BPV in individuals with depression or panic disorder. The two studies measuring long-term BPV were limited to the older population and found mixed results. Mental illness is significantly associated with an increased BPV in younger and middle-aged adults. All studies of ultra-short-term BPV using standard cardiac autonomic assessment; non-invasive continuous finger blood pressure and heart rate signals found significant association between BPV and mental illness. A mixed result related to degree of tilt during tilt assessment and between controlled and spontaneous breathing were observed in patients with psychological state. CONCLUSIONS: Current review found that people with mental illness is significantly associated with an increased BPV regardless of age. Since mental illness can contribute to the deterioration of autonomic function (HRV, BPV), early therapeutic intervention in mental illness may prevent diseases associated with autonomic dysregulation and reduce the likelihood of negative cardiac outcomes. Therefore, these findings may have important implications for patients' future physical health and well-being, highlighting the need for comprehensive cardiovascular risk reduction.


Asunto(s)
Trastorno Depresivo Mayor , Hipertensión , Trastornos Mentales , Adulto , Presión Sanguínea , Monitoreo Ambulatorio de la Presión Arterial , Humanos , Persona de Mediana Edad
5.
Biomed Eng Online ; 21(1): 29, 2022 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-35513815

RESUMEN

BACKGROUND: Falls among older adults have become a global concern. While previous studies have established associations between autonomic function indicator; heart rate variability (HRV) and blood pressure variability (BPV) with fall recurrence, as well as physical inactivity and psychological disorders as risk factors for falls, the influence of physical activity and psychological status on autonomic dysfunction observed among older fallers has not been adequately investigated. The aim of this study was to evaluate the relationship between psychological disorder and physical performance on the autonomic nervous system (ANS) in older fallers. We hypothesised that older fallers have poorer autonomic function, greater dependency on others and were associated with psychological disorders. Furthermore, we hypothesised that both physical performance and psychological status can contribute to the worsening of the autonomic function among the elderly. METHODS: In this cross-sectional survey, adults aged ≥ 60 years were recruited. Continuous non-invasive BP was monitored over 5 min of supine and 3 min of standing. Psychological status was assessed in terms of depression, anxiety, stress, and concern about falling, while functional status was measured using time-up-and-go, functional reach, handgrip and Lawton's Instrumental Activities of Daily Life (IADL) scale. RESULTS: A total of 62 participants were recruited consisting of 37 fallers and 25 non-fallers. Multivariate analysis revealed that Lawton IADL was independently associated with systolic blood pressure variability (SBPV) and diastolic blood pressure variability (DBPV) during both supine (SBPV: r2 = 0.080, p = 0.025; DBPV: r2 = 0.064, p = 0.046) and standing (SBPV: r2 = 0.112, p = 0.008; DBPV: r2 = 0.105, p = 0.011), while anxiety score was independently associated with SBPV and DBPV during standing (SBPV: r2 = 0.112, p = 0.009; DBPV: r2 = 0.105, p = 0.011) as compared to the other parameters. CONCLUSION: Our findings suggest that fallers had poorer ANS, greater dependence in IADLs, and were more anxious. IADL dependency and anxiety were the most predictive of autonomic dysfunction, and can be used in practice to identify poor autonomic function for the prevention of falls and cardiovascular diseases among older adults.


Asunto(s)
Monitoreo Ambulatorio de la Presión Arterial , Fuerza de la Mano , Anciano , Presión Sanguínea/fisiología , Estudios Transversales , Humanos , Rendimiento Físico Funcional
6.
J Theor Biol ; 509: 110527, 2021 01 21.
Artículo en Inglés | MEDLINE | ID: mdl-33096094

RESUMEN

Reperfusion of the blood flow to ischemic myocardium is the standard treatment for patients suffering myocardial infarction. However, the reperfusion itself can also induce myocardial injury, in which the actual mechanism and its risk factors remain unclear. This work aims to study the mechanism of ischemia-reperfusion treatment using a three-dimensional (3D) oxygen diffusion model. An electrical model is then coupled to an oxygen model to identify the possible region of myocardial damage. Our findings show that the value of oxygen exceeds its optimum (>1.0) at the ischemic area during early reperfusion period. This complication was exacerbated in a longer ischemic period. While a longer reperfusion time causes a continuous excessive oxygen supply to the ischemic area throughout the reperfusion time. This work also suggests the use of less than 0.8 of initial oxygen concentration in the reperfusion treatment to prevent undesired upsurge at the early reperfusion period and further myocardial injury. We also found the region at risk for myocardial injury is confined in the ischemic vicinity revealed by its electrical conductivity impairment. Although there is a risk that reperfusion leads to myocardial injury for excessive oxygen accumulation, the reperfusion treatment is helpful in reducing the infarct size.


Asunto(s)
Infarto del Miocardio , Isquemia Miocárdica , Daño por Reperfusión Miocárdica , Humanos , Miocardio , Reperfusión
7.
J Biomech Eng ; 143(8)2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-33764388

RESUMEN

A computational approach is used to investigate potential risk factors for distal stent graft-induced new entry (dSINE) in aortic dissection (AD) patients. Patient-specific simulations were performed based on computed tomography images acquired from six AD patients (three dSINE and three non-dSINE) to analyze the correlation between anatomical characteristics and stress/strain distributions. Sensitivity analysis was carried out using idealized models to independently assess the effect of stent graft length, stent tortuosity and wedge apposition angle at the landing zone on key biomechanical variables. Mismatch of biomechanical properties between the stented and nonstented regions led to high stress at the distal stent graft-vessel interface in all patients, as well as shear strain in the neighboring region, which coincides with the location of tear formation. Stress was observed to increase with the increase of stent tortuosity (from 263 kPa at a tortuosity angle of 50 deg to 313 kPa at 30 deg). It was further amplified by stent graft landing at the inflection point of a curve. Malapposition of the stent graft led to an asymmetrical segment within the aorta, therefore changing the location and magnitude of the maximum von Mises stress substantially (up to +25.9% with a +25 deg change in the distal wedge apposition angle). In conclusion, stent tortuosity and wedge apposition angle serve as important risk predictors for dSINE formation in AD patients.


Asunto(s)
Stents
8.
Magn Reson Med ; 81(2): 1385-1398, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30230606

RESUMEN

PURPOSE: To evaluate a 2D-4D registration-cum-segmentation framework for the delineation of left ventricle (LV) in late gadolinium enhanced (LGE) MRI and for the localization of infarcts in patient-specific 3D LV models. METHODS: A 3-step framework was proposed, consisting of: (1) 3D LV model reconstruction from motion-corrected 4D cine-MRI; (2) Registration of 2D LGE-MRI with 4D cine-MRI; (3) LV contour extraction from the intersection of LGE slices with the LV model. The framework was evaluated against cardiac MRI data from 27 patients scanned within 6 months after acute myocardial infarction. We compared the use of local Pearson's correlation (LPC) and normalized mutual information (NMI) as similarity measures for the registration. The use of 2 and 6 long-axis (LA) cine-MRI scans was also compared. The accuracy of the framework was evaluated using manual segmentation, and the interobserver variability of the scar volume derived from the segmented LV was determined using Bland-Altman analysis. RESULTS: LPC outperformed NMI as a similarity measure for the proposed framework using 6 LA scans, with Hausdorrf distance (HD) of 1.19 ± 0.53 mm versus 1.51 ± 2.01 mm (endocardial) and 1.21 ± 0.48 mm versus 1.46 ± 1.78 mm (epicardial), respectively. Segmentation using 2 LA scans was comparable to 6 LA scans with a HD of 1.23 ± 0.70 mm (endocardial) and 1.25 ± 0.74 mm (epicardial). The framework yielded a lower interobserver variability in scar volumes compared with manual segmentation. CONCLUSION: The framework showed high accuracy and robustness in delineating LV in LGE-MRI and allowed for bidirectional mapping of information between LGE- and cine-MRI scans, crucial in personalized model studies for treatment planning.


Asunto(s)
Gadolinio/química , Ventrículos Cardíacos/diagnóstico por imagen , Imagenología Tridimensional , Imagen por Resonancia Magnética , Infarto del Miocardio/diagnóstico por imagen , Algoritmos , Simulación por Computador , Humanos , Procesamiento de Imagen Asistido por Computador , Movimiento (Física) , Variaciones Dependientes del Observador , Pronóstico , Planificación de la Radioterapia Asistida por Computador , Reproducibilidad de los Resultados
9.
J Magn Reson Imaging ; 49(4): 1006-1019, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30211445

RESUMEN

BACKGROUND: Existing clinical diagnostic and assessment methods could be improved to facilitate early detection and treatment of cardiac dysfunction associated with acute myocardial infarction (AMI) to reduce morbidity and mortality. PURPOSE: To develop 3D personalized left ventricular (LV) models and thickening assessment framework for assessing regional wall thickening dysfunction and dyssynchrony in AMI patients. STUDY TYPE: Retrospective study, diagnostic accuracy. SUBJECTS: Forty-four subjects consisting of 15 healthy subjects and 29 AMI patients. FIELD STRENGTH/SEQUENCE: 1.5T/steady-state free precession cine MRI scans; LGE MRI scans. ASSESSMENT: Quantitative thickening measurements across all cardiac phases were correlated and validated against clinical evaluation of infarct transmurality by an experienced cardiac radiologist based on the American Heart Association (AHA) 17-segment model. STATISTICAL TEST: Nonparametric 2-k related sample-based Kruskal-Wallis test; Mann-Whitney U-test; Pearson's correlation coefficient. RESULTS: Healthy LV wall segments undergo significant wall thickening (P < 0.05) during ejection and have on average a thicker wall (8.73 ± 1.01 mm) compared with infarcted wall segments (2.86 ± 1.11 mm). Myocardium with thick infarct (ie, >50% transmurality) underwent remarkable wall thinning during contraction (thickening index [TI] = 1.46 ± 0.26 mm) as opposed to healthy myocardium (TI = 4.01 ± 1.04 mm). For AMI patients, LV that showed signs of thinning were found to be associated with a significantly higher percentage of dyssynchrony as compared with healthy subjects (dyssynchrony index [DI] = 15.0 ± 5.0% vs. 7.5 ± 2.0%, P < 0.01). Also, a strong correlation was found between our TI and left ventricular ejection fraction (LVEF) (r = 0.892, P < 0.01), and moderate correlation between DI and LVEF (r = 0.494, P < 0.01). DATA CONCLUSION: The extracted regional wall thickening and DIs are shown to be strongly correlated with infarct severity, therefore suggestive of possible practical clinical utility. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:1006-1019.


Asunto(s)
Imagenología Tridimensional , Imagen por Resonancia Cinemagnética , Infarto del Miocardio/diagnóstico por imagen , Disfunción Ventricular Izquierda/diagnóstico por imagen , Enfermedad Aguda , Anciano , Algoritmos , Simulación por Computador , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Informática Médica , Persona de Mediana Edad , Miocardio/patología , Variaciones Dependientes del Observador , Reconocimiento de Normas Patrones Automatizadas , Estudios Retrospectivos , Función Ventricular Izquierda
10.
J Magn Reson Imaging ; 48(1): 140-152, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29316024

RESUMEN

BACKGROUND: Left ventricle (LV) structure and functions are the primary assessment performed in most clinical cardiac MRI protocols. Fully automated LV segmentation might improve the efficiency and reproducibility of clinical assessment. PURPOSE: To develop and validate a fully automated neural network regression-based algorithm for segmentation of the LV in cardiac MRI, with full coverage from apex to base across all cardiac phases, utilizing both short axis (SA) and long axis (LA) scans. STUDY TYPE: Cross-sectional survey; diagnostic accuracy. SUBJECTS: In all, 200 subjects with coronary artery diseases and regional wall motion abnormalities from the public 2011 Left Ventricle Segmentation Challenge (LVSC) database; 1140 subjects with a mix of normal and abnormal cardiac functions from the public Kaggle Second Annual Data Science Bowl database. FIELD STRENGTH/SEQUENCE: 1.5T, steady-state free precession. ASSESSMENT: Reference standard data generated by experienced cardiac radiologists. Quantitative measurement and comparison via Jaccard and Dice index, modified Hausdorff distance (MHD), and blood volume. STATISTICAL TESTS: Paired t-tests compared to previous work. RESULTS: Tested against the LVSC database, we obtained 0.77 ± 0.11 (Jaccard index) and 1.33 ± 0.71 mm (MHD), both metrics demonstrating statistically significant improvement (P < 0.001) compared to previous work. Tested against the Kaggle database, the signed difference in evaluated blood volume was +7.2 ± 13.0 mL and -19.8 ± 18.8 mL for the end-systolic (ES) and end-diastolic (ED) phases, respectively, with a statistically significant improvement (P < 0.001) for the ED phase. DATA CONCLUSION: A fully automated LV segmentation algorithm was developed and validated against a diverse set of cardiac cine MRI data sourced from multiple imaging centers and scanner types. The strong performance overall is suggestive of practical clinical utility. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018.


Asunto(s)
Ventrículos Cardíacos/diagnóstico por imagen , Corazón/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Cinemagnética , Miocardio/patología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Automatización , Niño , Preescolar , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estudios Transversales , Diástole , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Lactante , Recién Nacido , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Movimiento (Física) , Redes Neurales de la Computación , Reconocimiento de Normas Patrones Automatizadas/métodos , Reproducibilidad de los Resultados , Relación Señal-Ruido , Procesos Estocásticos , Sístole , Adulto Joven
11.
J Magn Reson Imaging ; 45(2): 525-534, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27418150

RESUMEN

PURPOSE: To propose a cardiac motion tracking model that evaluates wall motion abnormality in postmyocardial infarction patients. Correlation between the motion parameter of the model and left ventricle (LV) function was also determined. MATERIALS AND METHODS: Twelve male patients with post-ST elevation myocardial infarction (post-STEMI) and 10 healthy controls of the same gender were recruited to undergo cardiac magnetic resonance imaging (MRI) using a 1.5T scanner. Using an infarct-specific LV division approach, the late gadolinium enhancement (LGE) MRI images were used to divide the LV on the tagged MRI images into infarct, adjacent, and remote sectors. Motion tracking was performed using the infarct-specific two-parameter empirical deformable model (TPEDM). The match quality was defined as the position error computed using root-mean-square (RMS) distance between the estimated and expert-verified tag intersections. The position errors were compared with the ones from our previously published fixed-sector TPEDM. Cine MRI images were used to calculate regional ejection fraction (REF). Correlation between the end-systolic contraction parameter (αES ) with REF was determined. RESULTS: The position errors in the proposed model were significantly lower than the fixed-sector model (P < 0.01). The median position errors were 0.82 mm versus 1.23 mm. The αES correlates significantly with REF (r = 0.91, P < 0.01). CONCLUSION: The infarct-specific TPEDM combines the morphological and functional information from LGE and tagged MRI images. It was shown to outperform the fixed-sector model in assessing regional LV dysfunction. The significant correlation between αES and REF added prognostic value because it indicated an impairment of cardiac function with the increase of infarct transmurality. LEVEL OF EVIDENCE: 3 J. Magn. Reson. Imaging 2017;45:525-534.


Asunto(s)
Imagen por Resonancia Cinemagnética/métodos , Modelos Cardiovasculares , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/fisiopatología , Técnica de Sustracción , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología , Simulación por Computador , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Movimiento , Imagen Multimodal/métodos , Infarto del Miocardio/complicaciones , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Disfunción Ventricular Izquierda/etiología
12.
Artif Organs ; 39(8): 681-90, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26146861

RESUMEN

This study in five large greyhound dogs implanted with a VentrAssist left ventricular assist device focused on identification of the precise site and physiological changes induced by or underlying the complication of left ventricular suction. Pressure sensors were placed in left and right atria, proximal and distal left ventricle, and proximal aorta while dual perivascular and tubing ultrasonic flow meters measured blood flow in the aortic root and pump outlet cannula. When suction occurred, end-systolic pressure gradients between proximal and distal regions of the left ventricle on the order of 40-160 mm Hg indicated an occlusive process of variable intensity in the distal ventricle. A variable negative flow difference between end systole and end diastole (0.5-3.4 L/min) was observed. This was presumably mediated by variable apposition of the free and septal walls of the ventricle at the pump inlet cannula orifice which lasted approximately 100 ms. This apposition, by inducing an end-systolic flow deficit, terminated the suction process by relieving the imbalance between pump requirement and delivery from the right ventricle. Immediately preceding this event, however, unnaturally low end-systolic pressures occurred in the left atrium and proximal left ventricle which in four dogs lasted for 80-120 ms. In one dog, however, this collapse progressed to a new level and remained at approximately -5 mm Hg across four heart beats at which point suction was relieved by manual reduction in pump speed. Because these pressures were associated with a pulmonary capillary wedge pressure of -5 mm Hg as well, they indicate total collapse of the entire pulmonary venous system, left atrium, and left ventricle which persisted until pump flow requirement was relieved by reducing pump speed. We suggest that this collapse caused the whole vascular region from pulmonary capillaries to distal left ventricle to behave as a Starling resistance which further reduced right ventricular output thus contributing to a major reduction in pump flow. We contend that similar complications of manual speed control also occur in the human subject and remain a major unsolved problem in the clinical management of patients implanted with rotary blood pumps.


Asunto(s)
Corazón Auxiliar/efectos adversos , Hemodinámica , Falla de Prótesis , Disfunción Ventricular Izquierda/etiología , Función Ventricular Izquierda , Animales , Modelos Animales de Enfermedad , Perros , Modelos Cardiovasculares , Diseño de Prótesis , Volumen Sistólico , Factores de Tiempo , Transductores de Presión , Resistencia Vascular , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/fisiopatología , Presión Ventricular
13.
Artif Organs ; 39(2): E24-35, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25345482

RESUMEN

The present study investigates the response of implantable rotary blood pump (IRBP)-assisted patients to exercise and head-up tilt (HUT), as well as the effect of alterations in the model parameter values on this response, using validated numerical models. Furthermore, we comparatively evaluate the performance of a number of previously proposed physiologically responsive controllers, including constant speed, constant flow pulsatility index (PI), constant average pressure difference between the aorta and the left atrium, constant average differential pump pressure, constant ratio between mean pump flow and pump flow pulsatility (ratioP I or linear Starling-like control), as well as constant left atrial pressure ( P l a ¯ ) control, with regard to their ability to increase cardiac output during exercise while maintaining circulatory stability upon HUT. Although native cardiac output increases automatically during exercise, increasing pump speed was able to further improve total cardiac output and reduce elevated filling pressures. At the same time, reduced venous return associated with upright posture was not shown to induce left ventricular (LV) suction. Although P l a ¯ control outperformed other control modes in its ability to increase cardiac output during exercise, it caused a fall in the mean arterial pressure upon HUT, which may cause postural hypotension or patient discomfort. To the contrary, maintaining constant average pressure difference between the aorta and the left atrium demonstrated superior performance in both exercise and HUT scenarios. Due to their strong dependence on the pump operating point, PI and ratioPI control performed poorly during exercise and HUT. Our simulation results also highlighted the importance of the baroreflex mechanism in determining the response of the IRBP-assisted patients to exercise and postural changes, where desensitized reflex response attenuated the percentage increase in cardiac output during exercise and substantially reduced the arterial pressure upon HUT.


Asunto(s)
Simulación por Computador , Ejercicio Físico , Corazón Auxiliar , Hemodinámica , Modelos Cardiovasculares , Presión Sanguínea , Gasto Cardíaco , Humanos
14.
Sensors (Basel) ; 15(6): 14142-61, 2015 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-26087370

RESUMEN

We present a novel approach to improve the estimation of systolic (SBP) and diastolic blood pressure (DBP) from oscillometric waveform data using variable characteristic ratios between SBP and DBP with mean arterial pressure (MAP). This was verified in 25 healthy subjects, aged 28 ± 5 years. The multiple linear regression (MLR) and support vector regression (SVR) models were used to examine the relationship between the SBP and the DBP ratio with ten features extracted from the oscillometric waveform envelope (OWE). An automatic algorithm based on relative changes in the cuff pressure and neighbouring oscillometric pulses was proposed to remove outlier points caused by movement artifacts. Substantial reduction in the mean and standard deviation of the blood pressure estimation errors were obtained upon artifact removal. Using the sequential forward floating selection (SFFS) approach, we were able to achieve a significant reduction in the mean and standard deviation of differences between the estimated SBP values and the reference scoring (MLR: mean ± SD = -0.3 ± 5.8 mmHg; SVR and -0.6 ± 5.4 mmHg) with only two features, i.e., Ratio2 and Area3, as compared to the conventional maximum amplitude algorithm (MAA) method (mean ± SD = -1.6 ± 8.6 mmHg). Comparing the performance of both MLR and SVR models, our results showed that the MLR model was able to achieve comparable performance to that of the SVR model despite its simplicity.


Asunto(s)
Determinación de la Presión Sanguínea/métodos , Presión Sanguínea/fisiología , Oscilometría/métodos , Procesamiento de Señales Asistido por Computador , Adulto , Electrocardiografía , Femenino , Humanos , Modelos Lineales , Masculino , Máquina de Vectores de Soporte , Adulto Joven
15.
Artif Organs ; 38(3): E57-67, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24422872

RESUMEN

In recent years, extensive studies have been conducted in the area of pumping state detection for implantable rotary blood pumps. However, limited studies have focused on automatically identifying the aortic valve non-opening (ANO) state despite its importance in the development of control algorithms aiming for myocardial recovery. In the present study, we investigated the performance of 14 ANO indices derived from the pump speed waveform using four different types of classifiers, including linear discriminant analysis, logistic regression, back propagation neural network, and k-nearest neighbors (KNN). Experimental measurements from four greyhounds, which take into consideration the variations in cardiac contractility, systemic vascular resistance, and total blood volume were used. By having only two indices, (i) the root mean square value, and (ii) the standard deviation, we were able to achieve an accuracy of 92.8% with the KNN classifier. Further increase of the number of indices to five for the KNN classifier increases the overall accuracy to 94.6%.


Asunto(s)
Válvula Aórtica , Corazón Auxiliar , Modelos Cardiovasculares , Flujo Pulsátil , Animales , Perros
16.
Artif Organs ; 38(3): E46-56, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24372519

RESUMEN

The application of rotary left ventricular (LV) assist devices (LVADs) is expanding from bridge to transplant, to destination and bridge to recovery therapy. Conventional constant speed LVAD controllers do not regulate flow according to preload, and can cause over/underpumping, leading to harmful ventricular suction or pulmonary edema, respectively. We implemented a novel adaptive controller which maintains a linear relationship between mean flow and flow pulsatility to imitate native Starling-like flow regulation which requires only the measurement of VAD flow. In vitro controller evaluation was conducted and the flow sensitivity was compared during simulations of postural change, pulmonary hypertension, and the transition from sleep to wake. The Starling-like controller's flow sensitivity to preload was measured as 0.39 L/min/mm Hg, 10 times greater than constant speed control (0.04 L/min/mm Hg). Constant speed control induced LV suction after sudden simulated pulmonary hypertension, whereas Starling-like control reduced mean flow from 4.14 to 3.58 L/min, maintaining safe support. From simulated sleep to wake, Starling-like control increased flow 2.93 to 4.11 L/min as a response to the increased residual LV pulsatility. The proposed controller has the potential to better match device outflow to patient demand in comparison with conventional constant speed control.


Asunto(s)
Corazón Auxiliar , Modelos Cardiovasculares , Flujo Pulsátil/fisiología , Función Ventricular Izquierda/fisiología , Diseño de Equipo , Humanos
17.
Artif Organs ; 38(7): 587-93, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24274084

RESUMEN

Clinically adequate implementation of physiological control of a rotary left ventricular assist device requires a sophisticated technique such as the recently proposed method based on the Frank-Starling mechanism. In this mechanism, the stroke volume of the heart increases in response to an increase in the volume of blood filling the left ventricle at the end of diastole. To emulate this process, changes in pump speed need to automatically regulate pump flow to ensure that the combined output of the left ventricle and pump match the output of the right ventricle across changing cardiovascular states. In this approach, we exploit the linear relationship between estimated mean pump flow (Q ̅ est) and pump flow pulsatility (PIQp) in a tracking control algorithm based on sliding mode control. The immediate response of the controller was assessed using a lumped parameter model of the cardiovascular system (CVS) and pump from which could be extracted both Q ̅ est and PIQp. Two different perturbations from the resting state in the presence of left ventricular failure were tested. The first was blood loss requiring a reduction in pump flow to match the reduced output from the right ventricle and to avoid the complication of ventricular suction. The second was exercise, requiring an increase in pump flow. The sliding mode controller induced the required changes in Qp within approximately five heart beats in the blood loss simulation and eight heart beats in the exercise simulation without clinically significant transients or steady-state errors.


Asunto(s)
Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Algoritmos , Simulación por Computador , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/cirugía , Ventrículos Cardíacos/fisiopatología , Humanos , Modelos Cardiovasculares , Diseño de Prótesis , Flujo Pulsátil , Función Ventricular Izquierda
18.
ScientificWorldJournal ; 2014: 652520, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24672348

RESUMEN

Aortic dissection, characterized by separation of the layers of the aortic wall, poses a significant challenge for clinicians. While type A aortic dissection patients are normally managed using surgical treatment, optimal treatment strategy for type B aortic dissection remains controversial and requires further evaluation. Although aortic diameter measured by CT angiography has been clinically used as a guideline to predict dilation in aortic dissection, hemodynamic parameters (e.g., pressure and wall shear stress), geometrical factors, and composition of the aorta wall are known to substantially affect disease progression. Due to the limitations of cardiac imaging modalities, numerical simulations have been widely used for the prediction of disease progression and therapeutic outcomes, by providing detailed insights into the hemodynamics. This paper presents a comprehensive review of the existing numerical models developed to investigate reasons behind tear initiation and progression, as well as the effectiveness of various treatment strategies, particularly the stent graft treatment.


Asunto(s)
Aneurisma de la Aorta/fisiopatología , Hemodinámica , Humanos
19.
Artículo en Inglés | MEDLINE | ID: mdl-39001803

RESUMEN

The improvement in congenital heart disease (CHD) treatment and management has increased the life expectancy in infants. However, the long-term efficacy is difficult to assess and thus, computational modelling has been applied for evaluating this. Here, we provide an overview of the applications of computational modelling in CHD based on three categories; CHD involving large blood vessels only, heart chambers only, and CHD that occurs at multiple heart structures. We highlight the advancement of computational simulation of CHD that uses multiscale and multiphysics modelling to ensure a complete representation of the heart and circulation. We provide a brief future direction of computational modelling of CHD such as to include growth and remodelling, detailed conduction system, and occurrence of myocardial infarction. We also proposed validation technique using advanced three-dimensional (3D) printing and particle image velocimetry (PIV) technologies to improve the model accuracy.

20.
Theor Biol Med Model ; 10: 35, 2013 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-23680359

RESUMEN

Despite the rapid advancement of left ventricular assist devices (LVADs), adverse events leading to deaths have been frequently reported in patients implanted with LVADs, including bleeding, infection, thromboembolism, neurological dysfunction and hemolysis. Cannulation forms an important component with regards to thrombus formation in assisted patients by varying the intraventricular flow distribution in the left ventricle (LV). To investigate the correlation between LVAD cannula placement and potential for thrombus formation, detailed analysis of the intraventricular flow field was carried out in the present study using a two way fluid structure interaction (FSI), axisymmetric model of a passive LV incorporating an inflow cannula. Three different cannula placements were simulated, with device insertion near the LV apex, penetrating one-fourth and mid-way into the LV long axis. The risk of thrombus formation is assessed by analyzing the intraventricular vorticity distribution and its associated vortex intensity, amount of stagnation flow in the ventricle as well as the level of wall shear stress. Our results show that the one-fourth placement of the cannula into the LV achieves the best performance in reducing the risk of thrombus formation. Compared to cannula placement near the apex, higher vortex intensity is achieved at the one-fourth placement, thus increasing wash out of platelets at the ventricular wall. One-fourth LV penetration produced negligible stagnation flow region near the apical wall region, helping to reduce platelet deposition on the surface of the cannula and the ventricular wall.


Asunto(s)
Cateterismo , Trombosis/fisiopatología , Humanos , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA