Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Pituitary ; 25(6): 1004-1014, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36322283

RESUMEN

PURPOSE: Central diabetes insipidus is a complication that may occur after pituitary surgery and has been difficult to predict. This study aimed to identify the cutoff levels of serum copeptin and its optimal timing for predicting the occurrence of central diabetes insipidus in patients who underwent transsphenoidal surgery. METHODS: This was a prospective observational study of patients who underwent transsphenoidal surgery for pituitary gland or stalk lesions. Copeptin levels were measured before surgery, 1 h after extubation, and on postoperative days 1, 2, 7, and 90. RESULTS: Among 73 patients, 14 (19.2%) and 13 (17.8%) patients developed transient and permanent central diabetes insipidus, respectively. There was no significant difference in copeptin levels before surgery and 1 h after extubation; copeptin levels on postoperative days 1, 2, 7, and 90 were significantly lower in patients with permanent central diabetes insipidus than in those without central diabetes insipidus. Copeptin measurement on postoperative day 2 exhibited the highest performance for predicting permanent central diabetes insipidus among postoperative days 1, 2, and 7 (area under the curve [95% confidence interval] = 0.754 [0.632-0.876]). Serum copeptin level at postoperative day 2(< 3.1 pmol/L) showed a sensitivity of 92.3% and a negative predictive value of 97.1%. The ratio of copeptin at postoperative day 2 to baseline (< 0.94) presented a sensitivity of 84.6% and a negative predictive value of 94.9%. The copeptin levels > 3.4 and 7.5 pmol/L at postoperative day 2 and 7 may have ruled out the occurrence of CDI with a negative predictive value of 100%. CONCLUSION: The copeptin level at postoperative day 2 and its ratio to baseline can predict the occurrence of permanent central diabetes insipidus after pituitary surgery.


Asunto(s)
Diabetes Insípida Neurogénica , Diabetes Mellitus , Enfermedades de la Hipófisis , Humanos , Diabetes Insípida Neurogénica/etiología , Enfermedades de la Hipófisis/complicaciones , Hipófisis/cirugía , Glicopéptidos , Complicaciones Posoperatorias/epidemiología
2.
Endocrinol Metab (Seoul) ; 39(1): 164-175, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38171208

RESUMEN

BACKGRUOUND: Delayed postoperative hyponatremia (DPH) is the most common cause of readmission after pituitary surgery. In this study, we aimed to evaluate the cutoff values of serum copeptin and determine the optimal timing for copeptin measurement for the prediction of the occurrence of DPH in patients who undergo endoscopic transsphenoidal approach (eTSA) surgery and tumor resection. METHODS: This was a prospective observational study of 73 patients who underwent eTSA surgery for pituitary or stalk lesions. Copeptin levels were measured before surgery, 1 hour after extubation, and on postoperative days 1, 2, 7, and 90. RESULTS: Among 73 patients, 23 patients (31.5%) developed DPH. The baseline ratio of copeptin to serum sodium level showed the highest predictive performance (area under the curve [AUROC], 0.699), and its optimal cutoff to maximize Youden's index was 2.5×10-11, with a sensitivity of 91.3% and negative predictive value of 92.0%. No significant predictors were identified for patients with transient arginine vasopressin (AVP) deficiency. However, for patients without transient AVP deficiency, the copeptin-to-urine osmolarity ratio at baseline demonstrated the highest predictive performance (AUROC, 0.725). An optimal cutoff of 6.5×10-12 maximized Youden's index, with a sensitivity of 92.9% and a negative predictive value of 94.1%. CONCLUSION: The occurrence of DPH can be predicted using baseline copeptin and its ratio with serum sodium or urine osmolarity only in patients without transient AVP deficiency after pituitary surgery.


Asunto(s)
Diabetes Insípida Neurogénica , Glicopéptidos , Hiponatremia , Enfermedades de la Hipófisis , Humanos , Arginina , Diabetes Insípida Neurogénica/complicaciones , Hiponatremia/diagnóstico , Hiponatremia/etiología , Sodio
3.
Clin Chem Lab Med ; 51(7): 1443-57, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23435152

RESUMEN

BACKGROUND: The 2009 Asian multicenter study for derivation of reference intervals (RIs) featured: 1) centralized measurements to exclude reagent-dependent variations; 2) inclusion of non-standardized analytes (hormones, tumor makers, etc.) in the target; and 3) cross-check of test results between the central and local laboratories. Transferability of centrally derived RIs for non-standardized analytes based on the cross-check was examined. METHODS: Forty non-standardized analytes were centrally measured in sera from 3541 reference individuals recruited by 63 laboratories. Forty-four laboratories collaborated in the cross-check study by locally measuring aliquots of sera from 9 to 73 volunteers (average 22.2). Linear relationships were obtained by the major-axis regression. Error in converting RIs using the regression line was expressed by the coefficient of variation of slope b [CV(b)]. CV(b) <10% was set as the cut-off value allowing the conversion. The significance of factors for partitioning RIs was determined similarly as in the first report. RESULTS: Significant sex-, age-, and region-related changes in test results were observed in 17, 15, and 11 of the 40 analytes, respectively. In the cross-comparison study, test results were not harmonized in the majority of immunologically measured analytes, but their average CV(b)s were <10% except for total protein, cystatin C, CA19-9, free thyroxine, and triiodothyronine. After conversion, 74% of centrally derived RIs were transferred to each local laboratory. CONCLUSIONS: Our results point to the feasibility of: 1) harmonizing test results across different laboratories; and 2) sharing centrally derived RIs of non-standardized analytes by means of comparative measurement of a set of commutable specimens.


Asunto(s)
Biomarcadores de Tumor/sangre , Proteínas Sanguíneas/análisis , Cistatina C/sangre , Lipoproteínas/sangre , Hormonas Tiroideas/sangre , Adulto , Factores de Edad , Anciano , Análisis de Varianza , Pueblo Asiatico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia , Factores Sexuales
4.
Clin Chim Acta ; 548: 117462, 2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37390943

RESUMEN

BACKGROUND: Clinical laboratory tests are inevitably affected by various factors. Therefore, when comparing consecutive test results, it is crucial to consider the inherent uncertainty of the test. Clinical laboratories use reference change value (RCV) to determine a significant change between 2 results. Whereas the criteria for the interpretation of consecutive results by clinicians are not well known. We investigated the clinician's interpretation of a clinically significant change in consecutive laboratory test results and compared them to RCV. METHODS: We performed a questionnaire survey on clinicians, which comprised 2 scenarios with 22 laboratory test items suggesting initial test results. Clinicians were asked to choose a result showing clinically significant change. RCV of the analytes from EFLM database were collected. RESULTS: We received 290 valid questionnaire responses. Clinicians' opinions on clinically significant change was inconsistent between clinicians and scenarios, and was generally larger than RCV. Clinicians commented that they were not familiar with the variability of the laboratory tests. CONCLUSIONS: Clinicians' opinions on clinically significant changes were more prominent than RCV. Meanwhile, they tended to neglect the analytical and biological variation. Laboratories should properly guide clinicians on the RCV of tests for better decision-making on patients' clinical states.


Asunto(s)
Servicios de Laboratorio Clínico , Laboratorios , Humanos , Técnicas de Laboratorio Clínico , Incertidumbre , Valores de Referencia
5.
Sci Rep ; 11(1): 17240, 2021 08 26.
Artículo en Inglés | MEDLINE | ID: mdl-34446748

RESUMEN

Copeptin levels reflect arginine vasopressin (AVP) release from the hypothalamus. Pituitary surgery often impairs AVP release and results in central diabetes insipidus (CDI). Here, we aimed to investigate how serum copeptin level changes 3 months after pituitary surgery and whether it has a diagnostic value for postoperative permanent CDI. Consecutive patients who underwent endoscopic transsphenoidal surgery at a single tertiary hospital were recruited. Serum copeptin levels were measured preoperatively and 3 months postoperatively. Among 88 patients, transient and permanent CDI occurred in 17 (19.3%) and 23 (26.1%), respectively. Three-month postoperative copeptin levels significantly declined from preoperative levels in permanent CDI group (P < 0.001, percentage difference = - 42.2%) and also in the transient CDI group (P = 0.002, - 27.2%). Three months postoperative copeptin level < 1.9 pmol/L under normal serum sodium levels was the optimal cutoff value for diagnosing permanent CDI with an accuracy of 81.8%, while 3-month postoperative copeptin level ≥ 3.5 pmol/L excluded the CDI with a negative predictive value of 100%. Conclusively, 3 months postoperative copeptin levels significantly decreased from preoperative levels in the transient CDI group as well as the permanent CDI group. Three-month postoperative copeptin levels ≥ 3.5 pmol/L under normal serum sodium levels may be diagnostic for excluding postoperative CDI.


Asunto(s)
Diabetes Insípida Neurogénica/diagnóstico , Glicopéptidos/sangre , Procedimientos Neuroquirúrgicos/métodos , Enfermedades de la Hipófisis/cirugía , Complicaciones Posoperatorias/diagnóstico , Seno Esfenoidal/cirugía , Adulto , Anciano , Diabetes Insípida Neurogénica/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neuroendoscopía/efectos adversos , Neuroendoscopía/métodos , Procedimientos Neuroquirúrgicos/efectos adversos , Complicaciones Posoperatorias/etiología , Periodo Posoperatorio , Periodo Preoperatorio , Curva ROC , Estudios Retrospectivos , Factores de Tiempo
6.
Gene Rep ; 23: 101100, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33778182

RESUMEN

The spike (S) protein mutations of SARS-CoV-2 are of major concern in terms of viral transmission and pathogenesis. Hence, we developed a PCR-based method to rapidly detect the 6 mutational hotspots (H49Y, G476S, V483A, H519Q, A520S, and D614G) in the S protein and applied this method to analyze the hotspots in the viral isolates from different geographical origins. Here, we identified that there was only the D614G mutation in the viral isolates. As of September 30, 2020, the analysis of 113,381 sequences available from the public repositories revealed that the SARS-CoV-2 variant carrying G614 has become the most prevalent form globally. Our results support recent epidemiological and genomic data demonstrating that the viral infectivity and transmission are enhanced by the S protein D614G mutation.

7.
Virus Res ; 297: 198398, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33753180

RESUMEN

Commercially available reverse transcription-polymerase chain reaction (RT-PCR) kits are being used as an important tool to diagnose SARS-CoV-2 infection in clinical laboratories worldwide. However, some kits lack sufficient clinical evaluation due to the need for emergency use caused by the current COVID-19 pandemic. Here we found that a novel insertion/deletion mutation in the nucleocapsid (N) gene of SARS-CoV-2 samples is a cause of negative results for the N gene in a widely used assay that received emergency use authorization (EUA) from US FDA and Conformite Europeenne-in vitro diagnostics (CE-IVD) from EU. Although SARS-CoV-2 is diagnosed positive by other target probes in the assay, our findings provide an evidence of the genetic variability and rapid evolution of SARS-CoV-2 as well as a reference in designing commercial RT-PCR assays.


Asunto(s)
COVID-19/virología , Proteínas de la Nucleocápside de Coronavirus/genética , Mutación INDEL , SARS-CoV-2/genética , COVID-19/diagnóstico , Prueba de Ácido Nucleico para COVID-19 , Reacciones Falso Negativas , Genes Virales , Humanos , Tamizaje Masivo , Pandemias , ARN Viral/análisis , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , SARS-CoV-2/aislamiento & purificación
8.
Ann Lab Med ; 40(1): 72-75, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31432643

RESUMEN

Accurate detection of BCR-ABL fusion transcripts at and below molecular response (MR) 4 (0.01% International Scale [IS]) is required for disease monitoring in patients with chronic myeloid leukemia (CML). We evaluated the analytical performance of the QXDx BCR-ABL %IS (Bio-Rad, Hercules, CA, USA) droplet digital PCR (ddPCR) assay, which is the first commercially available ddPCR-based in vitro diagnostics product. In precision analysis, the %CV was 9.3% and 3.0%, with mean values of 0.031% IS and 9.4% IS, respectively. The assay was linear in the first order, ranging from 0.032% IS to 20% IS. The manufacturer-claimed limit of blank, limit of detection, and limit of quantification were verified successfully. There was a very strong correlation between the results of the QXDx BCR-ABL %IS ddPCR assay and the ipsogen BCR-ABL1 Mbcr IS-MMR (Qiagen, Hilden, Germany) real-time quantitative PCR assay (r=0.996). In conclusion, the QXDx BCR-ABL %IS ddPCR assay can provide reliable results for CML patients.


Asunto(s)
Proteínas de Fusión bcr-abl/genética , Leucemia Mielógena Crónica BCR-ABL Positiva/diagnóstico , Reacción en Cadena de la Polimerasa/métodos , ADN de Neoplasias/genética , ADN de Neoplasias/metabolismo , Humanos , Límite de Detección , Juego de Reactivos para Diagnóstico
9.
Artículo en Inglés | MEDLINE | ID: mdl-28661432

RESUMEN

The purpose of this study was to determine the levels of trace metals in the blood of the general Korean population. A total of 258 healthy individuals, according to their regular medical check-ups, (119 males and 139 females, age ranging from 12 to 78 years old) were enrolled from December 2014 to December 2016. Levels of 10 trace elements were determined using inductively coupled plasma mass spectrometry (ICP-MS). The geometric mean (GM) levels for lead, arsenic, cesium, mercury, aluminum, cadmium, copper, manganese, selenium, and zinc were 15.97 µg/L, 7.19 µg/L, 2.39 µg/L, 3.41 µg/L, 10.57 µg/L, 0.78 µg/L, 979.8 µg/L, 11.06 µg/L, 111.37 µg/L, and 872.7 µg/L, respectively. There were significant gender-related differences in the levels of several metals; male individuals had higher Pb, As, Cs, Hg, and Se than females, while females had higher Cd, Cu, and Mn than males. We noticed remarkably high blood levels of Hg, As and Al in the Korean population. The element concentrations reported represent a new contribution to the knowledge of the blood chemistry for the Korea population. The data can be used to assess the clinical health of this population.


Asunto(s)
Contaminantes Ambientales/metabolismo , Metales/metabolismo , Oligoelementos/metabolismo , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , República de Corea , Adulto Joven
10.
Yonsei Med J ; 47(4): 480-4, 2006 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-16941736

RESUMEN

Clindamycin resistance in Staphylococcus species can be either constitutive or inducible. Inducible resistance cannot be detected by the conventional antimicrobial susceptibility test. In this study, we determined the prevalence of inducible clindamycin resistance in staphylococcal isolates at a Korean tertiary care hospital. Between February and September 2004, 1,519 isolates of Staphylococcus aureus and 1,043 isolates of coagulase-negative staphylococci (CNS) were tested for inducible resistance by the D-zone test. Overall, 17% of MRSA, 84% of MSSA, 37% of MRCNS, and 70% of MSCNS were susceptible to clindamycin. Of the erythromycin non-susceptible, clindamycin-susceptible isolates, 32% of MRSA, 35% of MSSA, 90% of MRCNS, and 94% of MSCNS had inducible clindamycin resistance. Inducible clindamycin resistance in staphylococci was highly prevalent in Korea. This study indicates importance of the D-zone test in detecting inducible clindamycin resistance in staphylococci to aid in the optimal treatment of patients.


Asunto(s)
Antibacterianos/farmacología , Antiinfecciosos/farmacología , Clindamicina/farmacología , Farmacorresistencia Microbiana , Pruebas de Sensibilidad Microbiana , Infecciones Estafilocócicas/metabolismo , Farmacorresistencia Bacteriana Múltiple , Humanos , Corea (Geográfico) , Prevalencia , Staphylococcus aureus/metabolismo
11.
Yonsei Med J ; 47(1): 43-54, 2006 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-16502484

RESUMEN

Monitoring temporal trends of antimicrobial resistance can provide useful information for the empirical selection of antimicrobial agents to treat infected patients and for the control of nosocomial infections. In this study, we analyzed antimicrobial resistance of clinically relevant bacteria in 2003 at Korean hospitals and at a commercial laboratory. The following organism-antimicrobial agent resistance combinations were very prevalent: oxacillin-resistant Staphylococcus aureus (68%), expanded-spectrum cephalosporin-resistant Klebsiella pneumoniae (25%), and fluoroquinolone-resistant Escherichia coli (33%), Acinetobacter spp. (58%), and Pseudomonas aeruginosa (40%). Moreover, gradual increases in vancomycin-resistant Enterococcus faecium (20%), cefoxitin-resistant E. coli (10%) and K. pneumoniae (23%), and imipenem-resistant P. aeruginosa (20%) and Acinetobacter spp. (13%) were also observed. The resistance rates of Acinetobacter spp. to most antimicrobial agents at hospitals and at the commercial laboratory were similar. Among the Acinetobacter spp. isolated at a tertiary-care hospital, 46.2% were multidrug-resistant to 9-12 of 13 antimicrobial agents, and 18.3% were panresistant. The exclusion of duplicate isolates at a tertiary-care hospital significantly lowered the proportion of oxacillin-resistant S. aureus, vancomycin-resistant E. faecium, and fluoroquinolone-resistant E. coli.


Asunto(s)
Antibacterianos/farmacología , Farmacorresistencia Bacteriana , Enterococcus faecium/efectos de los fármacos , Gammaproteobacteria/efectos de los fármacos , Infecciones por Bacterias Gramnegativas/microbiología , Infecciones por Bacterias Grampositivas/microbiología , Acinetobacter/efectos de los fármacos , Acinetobacter/aislamiento & purificación , Infecciones por Acinetobacter/tratamiento farmacológico , Infecciones por Acinetobacter/epidemiología , Infecciones por Acinetobacter/microbiología , Amicacina/farmacología , Enterococcus faecium/aislamiento & purificación , Fluoroquinolonas/farmacología , Gammaproteobacteria/aislamiento & purificación , Infecciones por Bacterias Gramnegativas/tratamiento farmacológico , Infecciones por Bacterias Gramnegativas/epidemiología , Infecciones por Bacterias Grampositivas/tratamiento farmacológico , Infecciones por Bacterias Grampositivas/epidemiología , Humanos , Imipenem/farmacología , Infecciones por Klebsiella/tratamiento farmacológico , Infecciones por Klebsiella/epidemiología , Infecciones por Klebsiella/microbiología , Klebsiella pneumoniae/efectos de los fármacos , Klebsiella pneumoniae/aislamiento & purificación , Corea (Geográfico)/epidemiología , Pruebas de Sensibilidad Microbiana , Vigilancia de la Población , Vancomicina/farmacología , Resistencia a la Vancomicina
12.
Asia Pac J Public Health ; 14(2): 64-8, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-12862409

RESUMEN

This study aimed to develop an Intelligent Laboratory Information System (ILIS) for the community health promotion centre in Kwachun city to help process an increasing amount of laboratory test data in an efficient manner, and to support the clinical decision-making of public health doctors. A sample of 170 cases was used for validation of the system. Overall, the system correctly predicted 92.5% of the cases. This paper also analysed the economic feasibility of the ILIS based on the Information Economics approach. The results showed that the ILIS not only helps screen more people by increasing the capacity of a health promotion centre, but also brings in more revenue to the centre.


Asunto(s)
Sistemas de Información en Laboratorio Clínico/organización & administración , Centros Comunitarios de Salud/organización & administración , Sistemas de Apoyo a Decisiones Clínicas , Promoción de la Salud/organización & administración , Sistemas de Información en Laboratorio Clínico/economía , Simulación por Computador , Humanos , Corea (Geográfico) , Hepatopatías/diagnóstico , Práctica de Salud Pública , Sensibilidad y Especificidad
13.
J Anal Methods Chem ; 2014: 787483, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24729916

RESUMEN

A fast, sensitive, and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was validated and then the levels of cortisol and cortisone from sera of healthy adults were determined by the LC-MS/MS method. One hundred µ L of serum sample was directly extracted by adding 2 mL ethyl acetate, followed by chromatographic separation on a C18 column with a mobile phase consisting of 5 mM ammonium acetate and methanol (25 : 75, v/v). The precision, accuracy, and average recovery of the method were 1.5-5.3%, 95.4-102.5%, and 96.4% for cortisol, and 1.9-6.0%, 89.2-98.8%, and 79.9% for cortisone, respectively. The method was linear from 1.0 to 500.0 ng/mL (r(2) = 0.999) for cortisol and 2.5 to 100.0 ng/mL (r(2) = 0.998) for cortisone. The limits of detection (LOD) and quantification (LOQ) were 0.2 and 1.0 ng/mL for cortisol, and 1.0 and 2.5 ng/mL for cortisone, respectively. The average cortisol concentration (133.9 ± 63.7 ng/mL) of samples collected between 9:00 and 11:00 a.m. was higher approximately 4.4 times than that of cortisone (30.5 ± 10.7 ng/mL) (P < 0.0001). The average cortisone/cortisol ratio was 0.225. Therefore, the LC-MS/MS method may be useful for the diagnosis of some adrenal diseases and the assessment of 11 ß -hydroxysteroid dehydrogenase (11 ß -HSD) activity in clinical laboratories.

14.
BMB Rep ; 43(7): 506-11, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20663413

RESUMEN

The levels of salivary cortisol and cortisone in Korean adults were measured for the first time using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The salivary cortisol and cortisone were separated within 10 min. The regression coefficients (r) of the calibration curves were greater than 0.999 for the two steroids. The limits of quantitation (LOQ) were 0.2 ng/ml for cortisol and 1 ng/ml for cortisone. The intra-day precisions of the assay were <3.9% and 8.6% for cortisol and cortisone respectively, and the inter-day precisions were <1.9% and 4.3% for cortisol and cortisone, respectively. The salivary cortisone concentrations were approximately 4-9 times higher than those of salivary cortisol during the daytime. Diurnal rhythms, during which the cortisol and cortisone concentrations were higher in the morning than in the afternoon, were also observed. The present assay may be useful for the diagnosis of several adrenal dysfunctions in clinical biochemistry.


Asunto(s)
Cromatografía Liquida/métodos , Cortisona/análisis , Hidrocortisona/análisis , Glándulas Salivales/química , Espectrometría de Masas en Tándem/métodos , Adulto , Humanos , Corea (Geográfico) , Glándulas Salivales/metabolismo
15.
BMB Rep ; 43(11): 761-5, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21110921

RESUMEN

Salivary testosterone levels in Korean adults were quantitatively measured for the first time by liquid chromatography-electrospray-tandem mass spectrometry (LC ESI MS/MS). Salivary testosterone was separated on a multiple reaction monitoring (MRM) chromatogram within 7 min. The LC ESI MS/MS assay was validated over the linearity range of 0.01-2.00 ng/ml (r=0.99987) using testosterone-d(3) as an internal standard. The lower limit of quantification (LOQ) was 0.01 ng/ml. The intra- and inter-assay precisions were 1.54% to 4.09% and 0.96% to 4.29%, respectively. The mean recovery was 93.32% (range 88.43-98.05%). The validated assay was then applied to measure the salivary testosterone levels of Korean adults. In men, the salivary testosterone level collected between 9:00-11:00 am was approximately 2.8 times higher than that in women (P < 0.0001). Salivary testosterone levels in both sexes negatively correlated with age. The present assay would also be useful in measuring salivary testosterone levels in clinical laboratories.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Glándulas Salivales/metabolismo , Espectrometría de Masa por Ionización de Electrospray/métodos , Testosterona/análisis , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Marcaje Isotópico , Masculino , Persona de Mediana Edad , República de Corea , Espectrometría de Masas en Tándem
16.
Korean J Lab Med ; 30(6): 726-33, 2010 Dec.
Artículo en Coreano | MEDLINE | ID: mdl-21157162

RESUMEN

BACKGROUND: Nationwide external quality assessment (EQA) of the fecal occult blood test (FOBT) in Korea was first introduced in 2007-2009. The EQA results were analyzed to assess the current status of FOBT and to plan the continuation of the EQA program. METHODS: The surveys included 40 hospitals in the preliminary survey conducted in 2007, 249 general hospitals in 2008, and 389 hospitals in 2009. In the surveys, the participating hospitals provided the results of the distributed materials and replies to the questionnaire on the FOBT test procedures and quality controls. RESULTS: In the surveys conducted between 2007 and 2009, a total of 650 institutes submitted 653 test system results; 3 institutes used 2 kinds of methods. All of the institutes used immunologic methods; 107 institutes (16.5%) used quantitative equipments and 546 institutes (84.0%) used qualitative kits. Most quantitative tests yielded consistent positive or negative results; however, their cut-off and measured values differed according to the equipments used. A low-level material tested in 2007 was negative in the quantitative methods but positive in some qualitative methods because of lower detection limits. The discordance rates among quantitative tests were 3.2% in 2007, 4.4% in 2008, and 0% in 2009 and the rates among qualitative tests were 13.8% in 2008 and 2.6% in 2009. Semi-solid EQA materials showed the ability to evaluate the overall test procedures with acceptable stability. CONCLUSIONS: In the first Korean FOBT EQA, commercially available EQA materials were proven to be stable. Continuation of the EQA program and further education of laboratory personnel are needed to reduce inconsistency in results. Further, the test kit, procedures, and result reports must be standardized.


Asunto(s)
Sangre Oculta , Técnicas de Laboratorio Clínico/instrumentación , Técnicas de Laboratorio Clínico/normas , Neoplasias Colorrectales/diagnóstico , Recolección de Datos , Hemoglobinas/análisis , Hemoglobinas/inmunología , Hemoglobinas/normas , Humanos , Control de Calidad , Juego de Reactivos para Diagnóstico , Encuestas y Cuestionarios , Temperatura
17.
Clin Chim Acta ; 402(1-2): 182-8, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19263528

RESUMEN

BACKGROUND: In the diagnosis of atopic diseases, allergen detection is a crucial step. Multiple allergen simultaneous test-chemiluminescent assay (MAST-CLA) is a simple and noninvasive method for in vitro screening of allergen-specific IgE antibodies. METHODS: The Korean Inhalant Panel test on 20 patients and Food Panel test on 19 patients were performed using the conventional manual MAST-CLA kit and the new automated MAST-CLA method (automated AP720S system for the Optigen Assay; Hitachi Chemical Diagnostics, Inc., USA) simultaneously. The results were evaluated for positive reactivity and concordance. RESULTS: The results of inhalant panel gave a relatively higher class level result than the food panel. The 8 patients out of 20 (40%) of the inhalation panel, and 9 patients out of 18 (47.4%) of the food panel showed 100% concordance between the 2 systems. Eighteen patients (90%) of the Inhalation Panel and sixteen patients (84.2%) of the Food Panel showed more than 91% concordance. CONCLUSIONS: These results suggest that the MAST-CLA assay using the new, automated AP720S analyzer performs well, showing a high concordance rate with conventional MAST-CLA. Compared to manual MAST-CLA, the automated AP720S system has a shorter assay time and uses a smaller serum volume (500 microl) along with other conveniences.


Asunto(s)
Alérgenos/análisis , Hipersensibilidad/diagnóstico , Inmunoglobulina E/inmunología , Mediciones Luminiscentes/instrumentación , Mediciones Luminiscentes/métodos , Adolescente , Adulto , Niño , Femenino , Humanos , Hipersensibilidad/inmunología , Masculino , Persona de Mediana Edad , Adulto Joven
18.
Korean J Lab Med ; 29(2): 163-70, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19411785

RESUMEN

BACKGROUND: The Korean Laboratory Accreditation Program (KLAP) by the Korean Society of Laboratory Medicine (KSLM) was started in 1999. We summarized history and achievement of KLAP for the last 8 yr. METHODS: We analyzed 8 yr data (1999-2006) of historical events, trends of participating laboratories, and scores according to the impact of the question to the outcome of the tests. Inspection check lists are for 'laboratory management', 'clinical chemistry', 'diagnostic hematology', 'clinical microbiology', 'diagnostic immunology', 'transfusion medicine', 'cytogenetics', 'molecular genetics', 'histocompatibility', 'flow cytometry', and 'comprehensive laboratory test verification report'. The laboratories with score 90 or higher got 2-yr certificate and laboratories with score between 60 and 89 got 1-yr certificate. The laboratories with score below 60 failed accreditation. RESULTS: The number of accredited laboratories was 2.4 times higher in 2006 (n=227) than in 1999 (n=96). Inspection check lists have been revised 5 times till 2006. The average accreditation rate was 99.6% during these periods and the 2-yr accreditation rate was 32.4% in 2000, 45.6% in 2001, 53.3% in 2002, 47.3% in 2003, 68.5% in 2004, 37.7% in 2005, and 47.7% in 2006. Number of participants in inspector training workshops increased from 89 in 2000 to 766 in 2006. CONCLUSIONS: The KLAP has been in place successfully and stabilized over the past 8 yr. It seemed to enhance the laboratory quality. Efforts for improvement of quality control and inspector training workshops appeared to be in the main contributing factors.


Asunto(s)
Laboratorios/normas , Patología Clínica/normas , Evaluación de Programas y Proyectos de Salud , Acreditación , Educación Médica Continua , Corea (Geográfico)
19.
Korean J Lab Med ; 28(2): 124-9, 2008 Apr.
Artículo en Coreano | MEDLINE | ID: mdl-18458508

RESUMEN

BACKGROUND: Due to the westernization of living environments in Korea, a number of allergy patients are greatly increasing. External quality control assessments are difficult for allergy tests due to the lack of reference methods. We surveyed the current status of allergy tests performed in medical laboratories in Korea to prepare for an external quality control assessment in the near future. METHODS: We conducted a survey on internal and external quality control trials, calibrations and its intervals, medical staffs, analyzers in use, an average number of tests per months, and report formats. RESULTS: Among the 85 laboratories surveyed, 61 were doing allergy tests including 6 reference laboratories. There were two different types of analyzers (1) qualitative or semi-quantitative and (2) quantitative. These analyzers use either chemiluminescent or immunoblot method. Fifty-five laboratories were using 'qualitative or semi-quantitative' analyzers as a screening test and 31 laboratories were using quantitative analyzers. Most of the laboratories were only doing an internal quality control assessment included in the test kits. Excepting a few laboratories, calibrations were not done. About 34 laboratories reported numerical values with interpretative reports prepared by laboratory medical doctors. CONCLUSIONS: The necessity of external quality control assessment has become an issue for improving the quality of allergy tests. But due to the lack of standardization, it is difficult to carry out external quality control assessments. By grouping the laboratories in terms of the type of analyzers, we could overcome the problem of analyzer variations and launch an external quality control assessment program in the near future.


Asunto(s)
Alérgenos/inmunología , Inmunoensayo/normas , Inmunoglobulina E/sangre , Humanos , Inmunoensayo/instrumentación , Immunoblotting/normas , Inmunoglobulina E/inmunología , Corea (Geográfico) , Mediciones Luminiscentes/normas , Control de Calidad
20.
Korean J Lab Med ; 28(5): 332-8, 2008 Oct.
Artículo en Coreano | MEDLINE | ID: mdl-18971613

RESUMEN

BACKGROUND: Although malaria-specific antibody or antigen test is useful for the diagnosis of malaria infection, its cost-effectiveness has to be concerned in the area where malaria prevalence is very low. We created a panel test composed of malaria non-specific parameters, namely hematology autoanalyzer-derived results with or without addition of HDL-cholesterol data, and evaluated its usefulness in comparison with malaria-specific antibody test. METHODS: For 395 patients tested for malaria smear, the hematology parameters such as platelet count, NRBC (%) and VCS (volume, conductivity, scattering) parameters of WBC, and HDL-cholesterol data were analyzed. Statistical significance of each parameter and that of panel test with or without addition of HDL-cholesterol were evaluated. RESULTS: Malaria antibody test showed sensitivity of 97.1% and specificity of 99.1%. Each parameter of platelet count, NRBC (%), D parameter and HDL-cholesterol showed sensitivity of 86.8%, 41.2%, 81.8%, and 70.6%, and specificity of 85.9%, 96.3%, 72.3%, and 81.7%, respectively. Panel test without including HDL-cholesterol showed sensitivity of 91.2% and specificity of 81.6%, and that including HDL-cholesterol showed sensitivity of 91.2% and specificity of 86.2%. CONCLUSIONS: The malaria non-specific panel test composed of hematology autoanalyzer-derived parameters showed relatively good, but slightly lower sensitivity than that of malaria-specific antibody test. It might be used as a screening test for the diagnosis of malaria infection, and addition of HDL cholesterol improved little the usefulness of the panel test.


Asunto(s)
HDL-Colesterol/sangre , Malaria Falciparum/diagnóstico , Animales , Autoanálisis , Biomarcadores , Diagnóstico Diferencial , Pruebas Hematológicas/economía , Pruebas Hematológicas/estadística & datos numéricos , Humanos , Malaria Falciparum/sangre , Plasmodium falciparum/aislamiento & purificación , Curva ROC , Juego de Reactivos para Diagnóstico , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA