Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 44(46): 4862-4873, 2023 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-37930776

RESUMEN

BACKGROUND AND AIMS: For patients with symptomatic, severe tricuspid regurgitation (TR), early results of transcatheter tricuspid valve (TV) intervention studies have shown significant improvements in functional status and quality of life associated with right-heart reverse remodelling. Longer-term follow-up is needed to confirm sustained improvements in these outcomes. METHODS: The prospective, single-arm, multicentre TRISCEND study enrolled 176 patients to evaluate the safety and performance of transcatheter TV replacement in patients with ≥moderate, symptomatic TR despite medical therapy. Major adverse events, reduction in TR grade and haemodynamic outcomes by echocardiography, and clinical, functional, and quality-of-life parameters are reported to one year. RESULTS: Enrolled patients were 71.0% female, mean age 78.7 years, 88.0% ≥ severe TR, and 75.4% New York Heart Association classes III-IV. Tricuspid regurgitation was reduced to ≤mild in 97.6% (P < .001), with increases in stroke volume (10.5 ± 16.8 mL, P < .001) and cardiac output (0.6 ± 1.2 L/min, P < .001). New York Heart Association class I or II was achieved in 93.3% (P < .001), Kansas City Cardiomyopathy Questionnaire score increased by 25.7 points (P < .001), and six-minute walk distance increased by 56.2 m (P < .001). All-cause mortality was 9.1%, and 10.2% of patients were hospitalized for heart failure. CONCLUSIONS: In an elderly, highly comorbid population with ≥moderate TR, patients receiving transfemoral EVOQUE transcatheter TV replacement had sustained TR reduction, significant increases in stroke volume and cardiac output, and high survival and low hospitalization rates with improved clinical, functional, and quality-of-life outcomes to one year. Funded by Edwards Lifesciences, TRISCEND ClinicalTrials.gov number, NCT04221490.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Anciano , Masculino , Insuficiencia de la Válvula Tricúspide/epidemiología , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Prospectivos , Calidad de Vida , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Índice de Severidad de la Enfermedad
2.
Catheter Cardiovasc Interv ; 101(1): 217-224, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36321593

RESUMEN

BACKGROUND: In the current study, we assess the predictive role of right and left atrial volume indices (RAVI and LAVI) as well as the ratio of RAVI/LAVI (RLR) on mortality following transcatheter mitral valve repair (TMVr). METHODS: Transthoracic echocardiograms of 158 patients who underwent TMVr at a single academic medical center from 2011 to 2018 were reviewed retrospectively. RAVI and LAVI were calculated using Simpson's method. Patients were stratified based on etiology of mitral regurgitation (MR). Cox proportional-hazard regression was created utilizing MR type, STS-score, and RLR to assess the independent association of RLR with survival. Kaplan-Meier analysis was used to analyze the association between RAVI and LAVI with all-cause mortality. Hemodynamic values from preprocedural right heart catheterization were also compared between RLR groups. RESULTS: Among 123 patients included (median age 81.3 years; 52.5% female) there were 50 deaths during median follow-up of 3.0 years. Patients with a high RAVI and low LAVI had significantly higher all-cause mortality while patients with high LAVI and low RAVI had significantly improved all-cause mortality compared to other groups (p = 0.0032). RLR was significantly associated with mortality in patients with both functional and degenerative MR (p = 0.0038). Finally, Cox proportion-hazard modeling demonstrated that an elevated RLR above the median value was an independent predictor of all-cause mortality [HR = 2.304; 95% CI = 1.26-4.21, p = 0.006] when MR type and STS score were accounted for. CONCLUSION: Patients with a high RAVI and low LAVI had significantly increased mortality than other groups following TMVr suggesting RA remodeling may predict worse outcomes following the procedure. Concordantly, RLR was predictive of mortality independent of MR type and preprocedural STS-score. These indices may provide additional risk stratification in patients undergoing evaluation for TMVr.


Asunto(s)
Fibrilación Atrial , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Femenino , Anciano de 80 o más Años , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Estudios Retrospectivos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Cateterismo Cardíaco/efectos adversos
3.
Pacing Clin Electrophysiol ; 46(2): 195-197, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36450156

RESUMEN

BACKGROUND: Patients with significant mitralregurgitation (MR) often experience atrial fibrillation (AF). The effects of transcatheter edge-to-edge repair (TEER) for MR on AF burden is unknown. METHODS: Patients who underwent TEER atthree institutions who also had a cardiac implantable electronic device with aright atrial lead were retrospectively identified. In patients with baseline AF, device data onAF burden and echocardiographic changes were recorded at baseline and 3- and 12-month follow up time points when available. Data is expressed as number (%) and median (interquartile range), withpaired values analyzed using the Wilcoxon signed-rank test. RESULTS: Overall 66 patients wereidentified, of whom 54 (82%) had baseline data on AF available for review. Of these, 18 (33%) had a baseline burden ofAF (median burden 100% [54-100%]). Patients were 77 (71-83) years old, 10 (56%) male, 14 (78%) White, and 3 (17%) Black. A significant reduction in AF burdenwas observed at 3 months (11 patients, p = 0.03) which did not retainsignificance at 12 months (8 patients, p = 0.69). Indexed maximal left atrial volumes did not significantly change inthose with paired studies available (p > 0.35 for both time points). CONCLUSIONS: In this multicenter cohort, one thirdof patients with severe MR undergoing TEER had an AF burden at baseline, whichwas found to be significantly lower at 3 month follow up. Further investigation is needed to confirm thefindings of this small cohort and determine its effects on downstream sequelaeof AF.


Asunto(s)
Fibrilación Atrial , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Masculino , Anciano , Anciano de 80 o más Años , Femenino , Fibrilación Atrial/cirugía , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento , Estudios Retrospectivos
4.
Heart Vessels ; 37(10): 1719-1727, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35534640

RESUMEN

Ventriculo-arterial (VA) coupling has been shown to have physiologic importance in heart failure (HF). We hypothesized that the systemic arterial pulsatility index (SAPi), a measure that integrates pulse pressure and a proxy for left ventricular end-diastolic pressure, would be associated with adverse outcomes in advanced HF. We evaluated the SAPi ([systemic systolic blood pressure-systemic diastolic blood pressure]/pulmonary artery wedge pressure) obtained from the final hemodynamic measurement in patients randomized to therapy guided by a pulmonary arterial catheter (PAC) and with complete data in the Evaluation Study of Congestive Heart Failure and Pulmonary Artery Catheterization Effectiveness (ESCAPE) trial. Cox proportional hazards regression was performed for the outcomes of (a) death, transplant, left ventricular assist device (DTxLVAD) or hospitalization, (DTxLVADHF) and (b) DTxLVAD. Among 142 patients (mean age 56.8 ± 13.3 years, 30.3% female), the median SAPi was 2.57 (IQR 1.63-3.45). Increasing SAPi was associated with significant reductions in DTxLVAD (HR 0.60 per unit increase in SAPi, 95% CI 0.44-0.84) and DTxLVADHF (HR 0.81 per unit increase, 95% CI 0.70-0.95). Patients with a SAPi ≤ 2.57 had a marked increase in both outcomes, including more than twice the risk of DTxLVAD (HR 2.19, 95% CI 1.11-4.30) over 6 months. Among advanced heart failure patients with invasive hemodynamic monitoring in the ESCAPE trial, SAPi was strongly associated with adverse clinical outcomes. These findings support further investigation of the SAPi to guide treatment and prognosis in HF undergoing invasive hemodynamic monitoring.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Adulto , Anciano , Cateterismo de Swan-Ganz , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Presión Esfenoidal Pulmonar
5.
Circulation ; 134(2): 130-40, 2016 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-27400898

RESUMEN

BACKGROUND: In the initial PARTNER trial (Placement of Aortic Transcatheter Valves) of transcatheter aortic valve replacement for high-risk (HR) and inoperable patients, mortality at 1 year was 24% in HR and 31% in inoperable patients. A recent report of the 30-day outcomes with the low-profile SAPIEN 3 transcatheter aortic valve replacement system demonstrated very low rates of adverse events, but little is known about the longer-term outcomes with this device. METHODS: Between October 2013 and September 2014, 583 HR (65%) or inoperable (35%) patients were treated via the transfemoral (84%) or transapical/transaortic (16%) access route at 29 US sites. Major clinical events at 1 year were adjudicated by an independent clinical events committee, and echocardiographic results were analyzed by a core laboratory. RESULTS: Baseline characteristics included age of 83 years, 42% female, and median Society of Thoracic Surgeons score of 8.4%. At the 1-year follow-up, survival (all-cause) was 85.6% for all patients, 87.3% in the HR subgroup, and 82.3% in the inoperable subgroup. Survival free of all-cause and cardiovascular mortality in the transfemoral patients from the HR cohort was 87.7% and 93.3%, respectively. There was no severe paravalvular leak. Moderate paravalvular leak (2.7%) was associated with an increase in mortality at 1 year, whereas mild paravalvular leak had no significant association with mortality. Symptomatic improvement as assessed by the percentage of patients in New York Heart Association class III and IV (90.1% to 7.7% at 1 year; P<0.0001) and by Kansas City Cardiomyopathy Questionnaire overall summary score (improved from 46.9 to 72.4; P<0.0001) was marked. Multivariable predictors of 1-year mortality included alternative access, Society of Thoracic Surgeons score, and disabling stroke. CONCLUSIONS: In this large, adjudicated registry of SAPIEN 3 HR and inoperable patients, the very low rates of important complications resulted in a strikingly low mortality rate at 1 year. Between 30 and 365 days, the incidence of moderate paravalvular aortic regurgitation did not increase, and no association between mild paravalvular leak and 1-year mortality was observed, although a small increase in disabling stroke occurred. These results, which likely reflect device iteration and procedural evolution, support the use of transcatheter aortic valve replacement as the preferred therapy in HR and inoperable patients with aortic stenosis. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01314313.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Diseño de Equipo , Femenino , Arteria Femoral , Humanos , Estimación de Kaplan-Meier , Masculino , Complicaciones Posoperatorias/epidemiología , Modelos de Riesgos Proporcionales , Recuperación de la Función , Sistema de Registros , Accidente Cerebrovascular/epidemiología , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
6.
Lancet ; 387(10034): 2218-25, 2016 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-27053442

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) with the SAPIEN 3 valve demonstrates good 30 day clinical outcomes in patients with severe aortic stenosis who are at intermediate risk of surgical mortality. Here we report longer-term data in intermediate-risk patients given SAPIEN 3 TAVR and compare outcomes to those of intermediate-risk patients given surgical aortic valve replacement. METHODS: In the SAPIEN 3 observational study, 1077 intermediate-risk patients at 51 sites in the USA and Canada were assigned to receive TAVR with the SAPIEN 3 valve [952 [88%] via transfemoral access) between Feb 17, 2014, and Sept 3, 2014. In this population we assessed all-cause mortality and incidence of strokes, re-intervention, and aortic valve regurgitation at 1 year after implantation. Then we compared 1 year outcomes in this population with those for intermediate-risk patients treated with surgical valve replacement in the PARTNER 2A trial between Dec 23, 2011, and Nov 6, 2013, using a prespecified propensity score analysis to account for between-trial differences in baseline characteristics. The clinical events committee and echocardiographic core laboratory methods were the same for both studies. The primary endpoint was the composite of death from any cause, all strokes, and incidence of moderate or severe aortic regurgitation. We did non-inferiority (margin 7·5%) and superiority analyses in propensity score quintiles to calculate pooled weighted proportion differences for outcomes. FINDINGS: At 1 year follow-up of the SAPIEN 3 observational study, 79 of 1077 patients who initiated the TAVR procedure had died (all-cause mortality 7·4%; 6·5% in the transfemoral access subgroup), and disabling strokes had occurred in 24 (2%), aortic valve re-intervention in six (1%), and moderate or severe paravalvular regurgitation in 13 (2%). In the propensity-score analysis we included 963 patients treated with SAPIEN 3 TAVR and 747 with surgical valve replacement. For the primary composite endpoint of mortality, strokes, and moderate or severe aortic regurgitation, TAVR was both non-inferior (pooled weighted proportion difference of -9·2%; 90% CI -12·4 to -6; p<0·0001) and superior (-9·2%, 95% CI -13·0 to -5·4; p<0·0001) to surgical valve replacement. INTERPRETATION: TAVR with SAPIEN 3 in intermediate-risk patients with severe aortic stenosis is associated with low mortality, strokes, and regurgitation at 1 year. The propensity score analysis indicates a significant superiority for our composite outcome with TAVR compared with surgery, suggesting that TAVR might be the preferred treatment alternative in intermediate-risk patients. FUNDING: None.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Tiempo de Internación , Masculino , Puntaje de Propensión , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad
7.
Catheter Cardiovasc Interv ; 90(1): 118-123, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28112463

RESUMEN

BACKGROUND: There are limited mechanical circulatory support options for patients with single ventricle (SV) anatomy. This is a multicenter, retrospective study of the Impella pump to support the systemic ventricle in a cohort of SV patients with Fontan circulation. METHODS: Patients with SV anatomy supported with an Impella device from 2012 to 2015 were included. Demographic information, indication for support, adverse events and short-term outcome data were collected. RESULTS: Ten patients were included. The median age and weight at implant was 26 years (4-38 years) and 64 kg (15-102 kg). Indications for support were systemic ventricular failure with cardiogenic shock (n = 8) or high-risk electrophysiology (EP) procedures (n = 2). The median duration of support was 49 hr (2.7-264 hr). Support was discontinued for ventricular recovery in five patients, transition to another device in two patients, completion of EP procedure in two patients and death in one patient. Survival to hospital discharge was 80%. Adverse events occurred in 4 patients. There were two cases of hemolysis, one case of increasing aortic valve insufficiency with implant and one asymptomatic access site thrombus. There were no bleeding or thromboembolic events. CONCLUSIONS: Impella devices can provide temporary support for the systemic ventricle in SV patients as a bridge to recovery or additional device. Procedural survival and adverse event profiles are favorable. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Procedimiento de Fontan/efectos adversos , Cardiopatías Congénitas/cirugía , Corazón Auxiliar , Disfunción Ventricular Izquierda/terapia , Función Ventricular Izquierda , Adolescente , Adulto , Preescolar , Ecocardiografía Doppler en Color , Ecocardiografía Transesofágica , Europa (Continente) , Femenino , Procedimiento de Fontan/mortalidad , Cardiopatías Congénitas/mortalidad , Cardiopatías Congénitas/fisiopatología , Mortalidad Hospitalaria , Humanos , Masculino , Diseño de Prótesis , Recuperación de la Función , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/mortalidad , Disfunción Ventricular Izquierda/fisiopatología , Adulto Joven
8.
Eur Heart J ; 37(28): 2252-62, 2016 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-27190101

RESUMEN

AIMS: Based on randomized trials using first-generation devices, transcatheter aortic valve replacement (TAVR) is well established in the treatment of high-risk (HR) patients with severe aortic stenosis (AS). To date, there is a paucity of adjudicated, prospective data evaluating outcomes with newer generation devices and in lower risk patients. We report early outcomes of a large, multicentre registry of inoperable, HR, and intermediate-risk (IR) patients undergoing treatment with the next-generation SAPIEN 3 transcatheter heart valve (THV). METHODS AND RESULTS: Patients with severe, symptomatic AS (583 high surgical risk or inoperable and 1078 IR) were enrolled in a multicentre, non-randomized registry at 57 sites in the USA and Canada. All patients received TAVR with the SAPIEN 3 system via transfemoral (n = 1443, 86.9%) and transapical or transaortic (n = 218, 13.1%) access routes. The rate of 30-day all-cause mortality was 2.2% in HR/inoperable patients [mean Society of Thoracic Surgeons (STS) score 8.7%] and 1.1% in IR patients (mean STS score 5.3%); cardiovascular mortality was 1.4 and 0.9%, respectively. In HR/inoperable patients, the 30-day rate of major/disabling stroke was 0.9%, major bleeding 14.0%, major vascular complications 5.1%, and requirement for permanent pacemaker 13.3%. In IR patients, the 30-day rate of major/disabling stroke was 1.0%, major bleeding 10.6%, major vascular complications 6.1%, and requirement for permanent pacemaker 10.1%. Mean overall Kansas City Cardiomyopathy Questionnaire score increased from 47.8 to 67.8 (HR/inoperable, P < 0.0001) and 54.7 to 74.0 (IR, P < 0.0001). Overall, paravalvular regurgitation at 30 days was none/trace in 55.9% of patients, mild in 40.7%, moderate in 3.4%, and severe in 0.0%. Mean gradients among patients with paired baseline and 30-day or discharge echocardiograms decreased from 45.8 mmHg at baseline to 11.4 mmHg at 30 days, while aortic valve area increased from 0.69 to 1.67 cm(2). CONCLUSIONS: The SAPIEN 3 THV system was associated with low rates of 30-day mortality and major/disabling stroke as well as low rates of moderate or severe paravalvular regurgitation. TRIAL REGISTRATION: ClinicalTrials.gov #NCT01314313.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Canadá , Cateterismo Cardíaco , Ecocardiografía , Humanos , Estudios Prospectivos , Reemplazo de la Válvula Aórtica Transcatéter , Resultado del Tratamiento
9.
J Drugs Dermatol ; 15(6): 763-5, 2016 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-27272086

RESUMEN

In 2013 brimonidine tartrate gel 0.33% (Mirvaso Gel, Galderma Laboratories, LP, Fort Worth, TX) was approved by the US Food and Drug Administration for the treatment of facial erythema of rosacea. It is the first and only drug on the market to address the hallmark redness of this chronic, inflammatory disease. Commonly reported adverse events include erythema/flushing worse than at baseline, most often occurring with the first application. We report a unique case of facial erythema of rosacea that responded to brimonidine gel with effective blanching for two years until the patient developed a paradoxical erythema reaction. This is an adverse reaction physicians should be aware of with continued prescription of brimonidine gel for their rosacea patients.

J Drugs Dermatol. 2016;15(6):763-765.


Asunto(s)
Tartrato de Brimonidina/administración & dosificación , Tartrato de Brimonidina/efectos adversos , Eritema/inducido químicamente , Eritema/diagnóstico , Rosácea/diagnóstico , Rosácea/tratamiento farmacológico , Administración Cutánea , Adulto , Esquema de Medicación , Femenino , Geles , Humanos , Resultado del Tratamiento
10.
N Engl J Med ; 366(18): 1686-95, 2012 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-22443479

RESUMEN

BACKGROUND: The Placement of Aortic Transcatheter Valves (PARTNER) trial showed that among high-risk patients with aortic stenosis, the 1-year survival rates are similar with transcatheter aortic-valve replacement (TAVR) and surgical replacement. However, longer-term follow-up is necessary to determine whether TAVR has prolonged benefits. METHODS: At 25 centers, we randomly assigned 699 high-risk patients with severe aortic stenosis to undergo either surgical aortic-valve replacement or TAVR. All patients were followed for at least 2 years, with assessment of clinical outcomes and echocardiographic evaluation. RESULTS: The rates of death from any cause were similar in the TAVR and surgery groups (hazard ratio with TAVR, 0.90; 95% confidence interval [CI], 0.71 to 1.15; P=0.41) and at 2 years (Kaplan-Meier analysis) were 33.9% in the TAVR group and 35.0% in the surgery group (P=0.78). The frequency of all strokes during follow-up did not differ significantly between the two groups (hazard ratio, 1.22; 95% CI, 0.67 to 2.23; P=0.52). At 30 days, strokes were more frequent with TAVR than with surgical replacement (4.6% vs. 2.4%, P=0.12); subsequently, there were 8 additional strokes in the TAVR group and 12 in the surgery group. Improvement in valve areas was similar with TAVR and surgical replacement and was maintained for 2 years. Paravalvular regurgitation was more frequent after TAVR (P<0.001), and even mild paravalvular regurgitation was associated with increased late mortality (P<0.001). CONCLUSIONS: A 2-year follow-up of patients in the PARTNER trial supports TAVR as an alternative to surgery in high-risk patients. The two treatments were similar with respect to mortality, reduction in symptoms, and improved valve hemodynamics, but paravalvular regurgitation was more frequent after TAVR and was associated with increased late mortality. (Funded by Edwards Lifesciences; ClinicalTrials.gov number, NCT00530894.).


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anticoagulantes/efectos adversos , Anticoagulantes/uso terapéutico , Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/clasificación , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/terapia , Cateterismo Cardíaco/efectos adversos , Femenino , Estudios de Seguimiento , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Hemorragia/etiología , Heparina/efectos adversos , Heparina/uso terapéutico , Humanos , Estimación de Kaplan-Meier , Masculino , Inhibidores de Agregación Plaquetaria/efectos adversos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Complicaciones Posoperatorias , Falla de Prótesis , Accidente Cerebrovascular/etiología , Tasa de Supervivencia , Resultado del Tratamiento , Ultrasonografía
11.
Catheter Cardiovasc Interv ; 86(5): 808-20, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26032565

RESUMEN

OBJECTIVE: To describe contemporary outcomes of balloon aortic valvuloplasty (BAVP) performed in 22 US centers. BACKGROUND: BAVP constitutes first-line therapy for congenital aortic stenosis (cAS) in many centers. METHODS: We used prospectively-collected data from two active, multi-institutional, pediatric cardiac catheterization registries. Acute procedural success was defined, for purposes of this review, as a residual peak systolic gradient≤35 mm Hg and no more than mild aortic regurgitation (AR) for patients with isolated cAS. For patients with mixed aortic valve disease, a residual peak systolic gradient≤35 mm Hg without worsening of AR was considered successful outcome. RESULTS: In 373 patients with a median age of 8 months (1 day to 40 years of age) peak systolic gradient had a median of 59 [50, 71] mm Hg pre-BAVP and 22 [15, 30] mm Hg post-BAVP (P<0.001). Procedural success was achieved in 160 patients (71%). The factors independently associated with procedural success were: first time intervention (OR=2.0 (1.0, 4.0) P=0.04), not-prostaglandin dependent, (OR=3.5 (1.5, 8.1); P=0.003), and isolated cAS (absence of AR) (OR=2.1 (1.1-3.9); P=0.03). Twenty percent of patients experienced adverse events, half of which were of high severity. There was no procedural mortality. Neonatal status was the only factor associated with increased risk of high severity adverse events (OR 3.7; 95% CI 1.5-9.0). CONCLUSION: In the current era, BAVP results in procedural success (gradient reduction with minimal increase in AR) in 71% of patients treated at US centers where BAVP is considered first-line therapy relative to surgery.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica , Valvuloplastia con Balón , Adolescente , Adulto , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/congénito , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón/efectos adversos , Distribución de Chi-Cuadrado , Niño , Preescolar , Femenino , Hemodinámica , Humanos , Lactante , Recién Nacido , Modelos Logísticos , Masculino , Oportunidad Relativa , Estudios Prospectivos , Recuperación de la Función , Sistema de Registros , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos , Adulto Joven
12.
J Vasc Interv Radiol ; 26(10): 1437-41, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26408210

RESUMEN

Transcaval aortic access has been used for deployment of transcatheter aortic valves in patients in whom conventional arterial approaches are not feasible. The present report describes its use for thoracic endovascular aortic repair (TEVAR) in a 61-year-old man with a descending thoracic aneurysm. Transcaval access was performed in lieu of a surgical iliac conduit in view of small atherosclerotic pelvic arteries. TEVAR was successfully performed, followed by intervascular tract occlusion with the use of a ventricular septal occluder. Computed tomography 2 d later demonstrated no extravasation. At 1 mo, the aneurysm was free of endoleaks, the aortocaval tract had healed, and the patient had returned to baseline functional status.


Asunto(s)
Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Cateterismo Periférico/métodos , Implantación de Prótesis/métodos , Stents , Vena Cava Inferior/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Radiografía , Resultado del Tratamiento
14.
Artículo en Inglés | MEDLINE | ID: mdl-38376702

RESUMEN

The objective of this preclinical study was to evaluate the feasibility and safety of transcatheter endocardial alginate hydrogel injection (TEAi) in a large animal model, utilizing the high-stiffness XDROP® alginate hydrogel in combination with the dedicated EndoWings® catheter-based system. All swine (n = 9) successfully underwent TEAi without complications. Acute results from a subset of animals (n = 5) demonstrated the ability of the catheter to access a wide range of endomyocardial areas and achieve consecutive circumferential hydrogel distribution patterns within the mid-left ventricular wall. Histological examinations at 6 months (n = 4) demonstrated that the XDROP® remained localized within the cardiac tissue. In addition, serial echocardiographic imaging showed that XDROP® had no adverse impacts on LV systolic and diastolic functions. In conclusion, this innovative combination technology has the potential to overcome the translational barriers related to alginate hydrogel delivery to the myocardium.

15.
J Drugs Dermatol ; 12(4): 481-4, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23652900

RESUMEN

We present a case of an otherwise healthy 81-year-old gentleman with multiple asymptomatic, erythematous, indurated papules and plaques, ranging in size from 0.5 to 1.5 cm, involving the dorsal, lateral, and palmar surfaces of the fingers bilaterally. A clinical suspicion of erythema elevatum diutinum (EED) led to initial treatment with topical dapsone 5% gel (ACZONE; Allergan Inc, Irvine, CA). Lesional biopsy demonstrated a dense perivascular infiltration of polymorphonuclear leukocytes and chronic inflammatory cells with perivascular fibrin deposition. Focal neutrophilic infiltration of superficial dermal blood vessel walls was present, suggesting a leukocytoclastic vasculitis. Stains for bacteria and fungi were negative. Clinicopathologic findings were consistent with EED, and in the interim, improvement with topical dapsone 5% gel was noted. Addition of oral dapsone led to complete resolution of the lesions. We present this case to illustrate the subtle, indolent clinical presentation of EED and demonstrate the uncomplicated use of topical dapsone 5% gel for rapid improvement and subsequent successful treatment of localized disease.


Asunto(s)
Antiinfecciosos/uso terapéutico , Dapsona/uso terapéutico , Vasculitis Leucocitoclástica Cutánea/tratamiento farmacológico , Administración Cutánea , Administración Oral , Anciano de 80 o más Años , Antiinfecciosos/administración & dosificación , Antiinfecciosos/efectos adversos , Dapsona/administración & dosificación , Dapsona/efectos adversos , Estudios de Seguimiento , Geles , Humanos , Masculino , Infiltración Neutrófila , Resultado del Tratamiento , Vasculitis Leucocitoclástica Cutánea/diagnóstico , Vasculitis Leucocitoclástica Cutánea/patología
16.
JACC Cardiovasc Interv ; 16(23): 2868-2879, 2023 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-37902145

RESUMEN

BACKGROUND: High surgical risk may preclude mitral valve replacement in many patients. Transcatheter mitral valve replacement (TMVR) using transfemoral transseptal access is a novel technology for the treatment of mitral regurgitation (MR) in high-risk surgical patients. OBJECTIVES: This analysis evaluates 30-day and 1-year outcomes of the Intrepid TMVR Early Feasibility Study in patients with ≥moderate-severe MR. METHODS: The Intrepid TMVR Early Feasibility Study is a multicenter, prospective, single-arm study. Clinical events were adjudicated by a clinical events committee; endpoints were defined according to Mitral Valve Academic Research Consortium criteria. RESULTS: A total of 33 patients, enrolled at 9 U.S. sites between February 2020 and August 2022, were included. The median age was 80 years, 63.6% of patients were men, and mean Society of Thoracic Surgeons Predicted Risk of Mortality for mitral valve replacement was 5.3%. Thirty-one (93.9%) patients were successfully implanted. Median postprocedural hospitalization length of stay was 5 days, and 87.9% of patients were discharged to home. At 30 days, there were no deaths or strokes, 8 (24.2%) patients had major vascular complications and none required surgical intervention, there were 4 cases of venous thromboembolism all successfully treated without sequelae, and 1 patient had mitral valve reintervention for severe left ventricular outflow tract obstruction. At 1 year, the Kaplan-Meier all-cause mortality rate was 6.7%, echocardiography showed ≤mild valvular MR, there was no/trace paravalvular leak in all patients, median mitral valve mean gradient was 4.6 mm Hg (Q1-Q3: 3.9-5.3 mm Hg), and 91.7% of survivors were in NYHA functional class I/II with a median 11.4-point improvement in Kansas City Cardiomyopathy Questionnaire overall summary scores. CONCLUSIONS: The early benefits of the Intrepid transfemoral transseptal TMVR system were maintained up to 1 year with low mortality, low reintervention, and near complete elimination of MR, demonstrating a favorable safety profile and durable valve function.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Masculino , Humanos , Anciano de 80 o más Años , Femenino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Estudios de Factibilidad , Estudios Prospectivos , Cateterismo Cardíaco/métodos , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología
17.
JACC Heart Fail ; 11(10): 1351-1362, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37480877

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is a common comorbidity in patients with heart failure with preserved ejection fraction (HFpEF) and in heart failure with mildly reduced ejection fraction (HFmrEF). OBJECTIVES: This study sought to describe AF burden and its clinical impact among individuals with HFpEF and HFmrEF who participated in a randomized clinical trial of atrial shunt therapy (REDUCE LAP-HF II [A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure]) and to evaluate the effect of atrial shunt therapy on AF burden. METHODS: Study investigators characterized AF burden among patients in the REDUCE LAP-HF II trial by using ambulatory cardiac patch monitoring at baseline (median patch wear time, 6 days) and over a 12-month follow-up (median patch wear time, 125 days). The investigators determined the association of baseline AF burden with long-term clinical events and examined the effect of atrial shunt therapy on AF burden over time. RESULTS: Among 367 patients with cardiac monitoring data at baseline and follow-up, 194 (53%) had a history of AF or atrial flutter (AFL), and median baseline AF burden was 0.012% (IQR: 0%-1.3%). After multivariable adjustment, baseline AF burden ≥0.012% was significantly associated with heart failure (HF) events (HR: 2.00; 95% CI: 1.17-3.44; P = 0.01) both with and without a history of AF or AFL (P for interaction = 0.68). Adjustment for left atrial reservoir strain attenuated the baseline AF burden-HF event association (HR: 1.71; 95% CI: 0.93-3.14; P = 0.08). Of the 367 patients, 141 (38%) had patch-detected AF during follow-up without a history of AF or AFL. Atrial shunt therapy did not change AF incidence or burden during follow-up. CONCLUSIONS: In HFpEF and HFmrEF, nearly 40% of patients have subclinical AF by 1 year. Baseline AF burden, even at low levels, is associated with HF events. Atrial shunt therapy does not affect AF incidence or burden. (A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure [REDUCE LAP-HF II]; NCT03088033).


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Humanos , Fibrilación Atrial/epidemiología , Volumen Sistólico , Atrios Cardíacos , Implantación de Prótesis , Pronóstico
18.
Catheter Cardiovasc Interv ; 80(4): 678-85, 2012 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-22422577

RESUMEN

OBJECTIVES: Review the prevalence, echocardiographic features and potential predictors of iatrogenic ASD (iASD) created with the MitraClip guiding catheter. BACKGROUND: Catheter-based repair of mitral regurgitation (MR) with the MitraClip device (Abbott Vascular, Menlo Park, CA), is performed through a 22-French transseptal guiding catheter. The echocardiographic prevalence of iASDs after the MitraClip procedure has not been reported. METHODS: Thirty subjects undergoing MitraClip repair during the roll-in phase of the EVEREST II randomized trial who had baseline, 30 day, 6 and 12 month transthoracic echocardiograms (TTEs) available for review were included. Patients who underwent surgery for MR within the first 12 months were excluded. Residual iASD size, right ventricular (RV) size, left atrial (LA) volume, and tricuspid/MR grade were quantified. RESULTS: iASDs were found at 12 months in 8 patients (27%) with a mean diameter of 6.6 ± 3.1 mm. Subjects with iASD at 12 months had more residual MR, increased TR and a trend toward larger LA volumes than non-iASD patients. 83% of non-ASD patients were free from MR > 2+ at 12 mos. vs. 38% of those with iASD (p=0.016). There were no other significant associations between clinical and echocardiographic variables and the persistence of iASD. CONCLUSIONS: After MitraClip repair, persistent iASDs occur at a rate comparable to reports after other transseptal interventional procedures and do not appear hemodynamically significant. Patients with persistent iASDs had less MR reduction at 12-months and a trend toward larger LA volumes, suggesting that increased LA pressure may be a mechanism for persistent iASD.


Asunto(s)
Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Catéteres , Ecocardiografía , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/epidemiología , Enfermedad Iatrogénica , Insuficiencia de la Válvula Mitral/terapia , Tabique Interatrial/diagnóstico por imagen , Tabique Interatrial/lesiones , Ecocardiografía Doppler , Ecocardiografía Doppler en Color , Ecocardiografía Tridimensional , Lesiones Cardíacas/fisiopatología , Hemodinámica , Humanos , Insuficiencia de la Válvula Mitral/fisiopatología , Valor Predictivo de las Pruebas , Prevalencia , Factores de Riesgo , Factores de Tiempo
19.
JACC Cardiovasc Interv ; 15(19): 1921-1932, 2022 10 10.
Artículo en Inglés | MEDLINE | ID: mdl-36202561

RESUMEN

BACKGROUND: Tricuspid regurgitation (TR) is prevalent and undertreated, with mortality and morbidity increasing with TR severity. Given poor outcomes with medical therapy and high in-hospital mortality for isolated tricuspid valve surgery, emerging transcatheter repair devices offer a promising alternative. OBJECTIVES: The Edwards Cardioband Tricuspid Valve Reconstruction System Early Feasibility study (NCT03382457) evaluates the treatment of functional TR via annular reduction with the Cardioband Tricuspid Valve Reconstruction System (Edwards Lifesciences). METHODS: Patients with ≥ moderate functional TR were eligible for this prospective, single-arm multicenter study. At 1 year, patients were evaluated for echocardiographic parameters, clinical and quality-of-life measures, and major adverse events. RESULTS: The 37 patients enrolled had a mean age of 78 years; 76% were female; and they had ≥ severe functional (97.3%) or mixed (2.7%) TR, atrial flutter/fibrillation (97%), and New York Heart Association functional class III/IV (65%). At 1 year, 73.0% achieved ≤ moderate TR (P < 0.0001), and 73.1% had ≥2 grade reductions. Echocardiography showed significant reductions in the tricuspid annulus diameter (P < 0.0001), mean vena contracta (P < 0.0001), proximal isovelocity surface area effective regurgitant orifice area (P < 0.0001), right ventricular end-diastolic diameter (P < 0.0001), and inferior vena contracta (P = 0.0006). New York Heart Association functional class improved significantly (P < 0.0001), with 92.3% achieving class I/II, and Kansas City Cardiomyopathy Questionnaire scores improved by 19.0 points (P < 0.0001). One-year cardiovascular mortality was 8.1%, reinterventions were necessary in 5.4%, major access site complications occurred in 8.1%, and severe bleeding was noted in 35.1% of patients. Kaplan-Meier estimates of survival and freedom from heart failure rehospitalization were 85.9% and 88.7%, respectively. CONCLUSIONS: One-year experience using the Cardioband system for tricuspid valve repair shows high survival and low rehospitalization rates with durable outcomes in TR reduction and echocardiographic, clinical, and quality-of-life outcomes.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Anciano , Cateterismo Cardíaco , Estudios de Factibilidad , Femenino , Humanos , Masculino , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía
20.
JACC Cardiovasc Interv ; 14(8): 879-889, 2021 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-33888233

RESUMEN

OBJECTIVES: The authors sought to evaluate the association between mean mitral valve gradient (MVG) and clinical outcomes among patients who underwent MitraClip treatment for secondary mitral regurgitation (SMR) in the COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation) trial. BACKGROUND: In the COAPT trial, patients with heart failure (HF) and severe SMR who remained symptomatic despite guideline-directed medical therapy had marked 2-year reductions in mortality and HF hospitalizations after treatment with MitraClip. METHODS: MitraClip-treated patients were divided into quartiles (Q) based on discharge echocardiographic MVG (n = 250). Endpoints including all-cause mortality, HF hospitalization, and health status measures at 2 years were compared between quartiles. RESULTS: Mean MVG after MitraClip was 2.1 ± 0.4 mm Hg, 3.0 ± 0.2 mm Hg, 4.2 ± 0.5 mm Hg, and 7.2 ± 2.0 mm Hg in Q1 (n = 63), Q2 (n = 61), Q3 (n = 62), and Q4 (n = 64), respectively. There was no difference across quartiles in the 2-year composite endpoint of all-cause mortality or HF hospitalization (43.2%, 49.2%, 40.6%, and 40.9%, respectively; p = 0.80), nor in improvements in New York Heart Association functional class, Kansas City Cardiomyopathy Questionnaire score, or 6-min walk time. Results were similar after adjustment for baseline clinical and echocardiographic characteristics, post-procedure MR grade, and number of clips (all-cause mortality or HF hospitalization Q4 [44.6%] vs. Q1 to Q3 [40.3%]; adjusted hazard ratio: 1.23, 95% confidence interval: 0.60 to 2.51; p = 0.57). CONCLUSIONS: Among HF patients with severe SMR, higher MVGs on discharge did not adversely affect clinical outcomes following MitraClip. These findings suggest that in select patients with HF and SMR otherwise meeting the COAPT inclusion criteria, the benefits of MR reduction may outweigh the effects of mild-to-moderate mitral stenosis after MitraClip.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Ecocardiografía , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/terapia , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA