Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 34(2): 270-278, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36434797

RESUMEN

INTRODUCTION: Pulmonary vein isolation (PVI) is effective at treating 50% of unselected patients with persistent atrial fibrillation (AF). Alternatively, PVI combined with a new ablation strategy entitled the Marshall-PLAN ensures a 78% 1-year sinus rhythm (SR) maintenance rate in the same population. However, a substantial subset of patients could undergo the Marshall-PLAN unnecessarily. It is therefore essential to identify those patients who can be treated with PVI alone versus those who may truly benefit from the Marshall-PLAN before ablation is performed. In this context, we hypothesized that electrical cardioversion (EC) could help to select the most appropriate strategy for each patient. METHODS: In this multicentre, prospective, randomized study, patients with AF recurrence within 4 weeks after EC will be randomized 1:1 to PVI alone or the Marshall-PLAN. Conversely, patients in whom SR is maintained for ≥4 weeks after EC will be treated with PVI only and included in a prospective registry. The primary endpoint will be the 1-year SR maintenance rate after a single ablation procedure. RESULTS AND CONCLUSION: The Marshall-PLAN might be necessary in patients with an advanced degree of persistent AF (i.e., where SR is not maintained for ≥4 uninterrupted weeks after EC). Conversely, in patients with mild or moderate persistent AF (i.e., where SR is maintained for ≥4 weeks after EC), PVI alone might be a sufficient ablation strategy. The PACIFIC trial is the first study designed to assess whether rhythm monitoring after EC could help to identify patients who should undergo adjunctive ablation strategies beyond PVI.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Cardioversión Eléctrica/efectos adversos , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
2.
Europace ; 25(11)2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-37851513

RESUMEN

AIMS: The optimal interlesion distance (ILD) for 90 and 50 W radiofrequency applications with low ablation index (AI) values in the atria has not been established. Excessive ILDs can predispose to interlesion gaps, whereas restrictive ILDs can predispose to procedural complications. The present study sought, therefore, to experimentally determine the optimal ILD for 90 W-4 s and 50 W applications with low AI values to optimize catheter ablation outcomes in humans. METHODS AND RESULTS: Posterior intercaval lines were created in eight adult sheep using CARTO and the QDOT-MICRO catheter in a temperature-controlled mode. In four animals, the lines were created with 50 W applications, a target AI value ≥350, and ILDs of 6, 5, 4, and 3 mm, respectively. In the other four animals, the lines were created with 90 W-4 s applications and ILDs of 6, 5, 4, and 3 mm, respectively. Activation maps were created immediately after ablation and at 21 days to assess linear block prior to gross and histological analyses. All eight lines appeared transmural and continuous on histology. However, for 50 W-only applications with an ILD of 3 mm resulted in durable linear electrical block, whereas for 90 W applications, only the lines with ILDs of 4 and 3 mm were blocked. No complications were detected during ablation procedures, but all power and ILD combinations except 50 W-6 mm resulted in asymptomatic shallow lung lesions. CONCLUSION: In the intercaval region in sheep, for 50 W applications with an AI value of ∼370, the optimal ILD is 3 mm, whereas for 90 W-4 s applications, the optimal ILD is 3-4 mm.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Enfermedades Pulmonares Intersticiales , Venas Pulmonares , Humanos , Adulto , Animales , Ovinos , Venas Pulmonares/cirugía , Atrios Cardíacos/cirugía , Atrios Cardíacos/patología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Catéteres , Enfermedades Pulmonares Intersticiales/patología , Enfermedades Pulmonares Intersticiales/cirugía , Fibrilación Atrial/cirugía , Fibrilación Atrial/patología , Resultado del Tratamiento
3.
Pacing Clin Electrophysiol ; 46(10): 1235-1238, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-36811180

RESUMEN

Left ventricular (LV) summit premature ventricular contractions (PVCs) are often unresponsive to radiofrequency (RF) ablation. Retrograde venous ethanol infusion (RVEI) can be a valuable alternative in this scenario. A 43-year-old woman without structural heart disease presented with LV summit PVCs unresponsive to RF ablation because of their deep-seated origin. Unipolar pace mapping performed through a wire inserted into a branch of the distal great cardiac vein (GCV) demonstrated 12/12 concordance with the clinical PVCs thus indicating close proximity to PVCs' origin. RVEI abolished the PVCs without complications. Subsequently, magnetic resonance imaging (MRI) evidenced an intramural myocardial scar produced by ethanol ablation. In conclusion, RVEI effectively and safely treated PVC arising from a deep site in the LVS. The scar provoked by chemical damage was well characterized by MRI imaging.


Asunto(s)
Ablación por Catéter , Complejos Prematuros Ventriculares , Femenino , Humanos , Adulto , Complejos Prematuros Ventriculares/cirugía , Cicatriz/cirugía , Etanol , Ablación por Catéter/métodos , Imagen por Resonancia Magnética , Resultado del Tratamiento
4.
Heart Fail Rev ; 27(1): 271-280, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-32535741

RESUMEN

A focal contraction pattern in takotsubo syndrome (TTS) is considered rare. Due to its peculiar presentation, which includes segmental left ventricular (LV) regional wall motion abnormalities (RWMA), the focal TTS pattern may be hardly differentiable from other entities, such as myocarditis or myocardial infarction. We performed a comprehensive systematic literature review researching for works in English published in Journals indexed in Embase, available online for consultation, using the following keywords (in Title and/or Abstract): ("takotsubo" OR "broken heart" OR "apical ballooning" OR "stress cardiomyopathy") AND ("focal" OR "atypical" OR "variant" OR "segments"). Thirty-three papers were retrieved: 17 case reports, 6 case series, and 10 population studies-with a total of 166 focal TTS patients. Prevalence of focal TTS ranged between 0.1% and 14% (pooled mean: 2.8%). Mean age of onset (58 years), gender distribution (80% of females), and type of triggers appeared similar to those reported in typical TTS. RWMA more frequently involved the interventricular septum and the anterolateral LV segments, with often preserved LV ejection fraction. In the majority of focal TTS reports that included adequate ECG information (n = 13), abnormalities were localized and not diffuse, always matching RWMA, and in 3 cases, reciprocal changes were observed. No in-hospital nor long-term deaths were reported. The focal TTS contraction pattern may be more prevalent than currently reported. Though possibly presenting with similar demographic background compared with typical TTS, the focal variant might be characterized by peculiar ECG modifications and better prognosis.


Asunto(s)
Cardiomiopatía de Takotsubo , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Persona de Mediana Edad , Miocardio , Volumen Sistólico , Cardiomiopatía de Takotsubo/diagnóstico , Cardiomiopatía de Takotsubo/epidemiología , Función Ventricular Izquierda
5.
Pacing Clin Electrophysiol ; 45(6): 752-760, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35403246

RESUMEN

BACKGROUND: Little is known regarding the characterization of electrical substrate in both atria in patients with atrial fibrillation (AF). METHODS: Eight consecutive patients undergoing AF ablation (five paroxysmal, three persistent) underwent electrical substrate characterization during sinus rhythm. Mapping of the left (LA) and right atrium (RA) was performed with the use of the HD Grid catheter (Abbott). Bipolar voltage maps were analyzed to search for low voltage areas (LVA), the following electrophysiological phenomena were assessed: (1) slow conduction corridors, and (2) lines of block. EGMs were characterized to search for fractionation. Electrical characteristics were compared between atria and between paroxysmal versus persistent AF patients. RESULTS: In the RA, LVAs were present in 60% of patients with paroxysmal AF and 100% of patients with persistent AF. In the LA, LVAs were present in 40% of patients with paroxysmal AF and 66% of patients with persistent AF. The areas of LVA in the RA and LA were 4.8±7.3 cm2 and 7.8±13.6 cm2 in patients with paroxysmal AF versus 11.7±3.0 cm2 and 2.1±1.8 cm2 in patients with persistent AF. In the RA, slow conduction corridors were present in 40.0% (paroxysmal AF) versus 66.7% (persistent AF) whereas in the LA, slow conduction corridors occurred in 20.0% versus 33.3% respectively (p = ns). EGM analysis showed more fractionation in persistent AF patients than paroxysmal (RA: persistent AF 10.8 vs. paroxysmal AF 4.7%, p = .036, LA: 10.3 vs. 4.1%, p = .108). CONCLUSION: Bi-atrial involvement is present in patients with paroxysmal and persistent AF. This is expressed by low voltage areas and slow conduction corridors whose extension progresses as the arrhythmia becomes persistent. This electrophysiological substrate demonstrates the important interplay with the pulmonary vein triggers to constitute the substrate for persistent arrhythmia.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/cirugía , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos , Humanos , Venas Pulmonares/cirugía
6.
Pacing Clin Electrophysiol ; 45(2): 219-228, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34919281

RESUMEN

INTRODUCTION: Electrogram (EGM) fractionation is often associated with diseased atrial tissue; however, mechanisms for fractionation occurring above an established threshold of 0.5 mV have never been characterized. We sought to investigate during sinus rhythm (SR) the mechanisms underlying bipolar EGM fractionation with high-density mapping in patients with atrial fibrillation (AF). METHODS: Forty-five patients undergoing AF ablation (73% paroxysmal, 27% persistent) were mapped at high density (18562 ± 2551 points) during SR (Rhythmia). Only bipolar EGMs with voltages above 0.5 mV were considered for analysis. When fractionation (> 40 ms and >4 deflections) was detected, we classified the mechanisms as slow conduction, wave-front collision, or a pivot point. The relationship between EGM duration and amplitude, and tissue anisotropy and slow conduction, was then studied using a computational model. RESULTS: Of the 45 left atria analyzed, 133 sites of EGM fragmentation were identified with voltages above 0.5 mV. The most frequent mechanism (64%) was slow conduction (velocity 0.45 m/s ± 0.2) with mean EGM voltage of 1.1 ± 0.5 mV and duration of 54.9 ± 9.4 ms. Wavefront collision was the second most frequent (19%), characterized by higher voltage (1.6 ± 0.9 mV) and shorter duration (51.3 ± 11.3 ms). Pivot points (9%) were associated with the highest degree of fractionation with 70.7 ± 6.6 ms and 1.8 ± 1 mV. In 10 sites (8%) fractionation was unexplained. The EGM duration was significantly different among the 3 mechanisms (p = .0351). CONCLUSION: In patients with a history of AF, EGM fractionation can occur at amplitudes > 0.5 mV when in SR in areas often considered not to be diseased tissue. The main mechanism of EGM fractionation is slow conduction, followed by wavefront collision and pivot sites.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Anciano , Simulación por Computador , Mapeo Epicárdico , Femenino , Humanos , Italia , Masculino
7.
Pacing Clin Electrophysiol ; 45(1): 23-34, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34841552

RESUMEN

BACKGROUND: Left atrial appendage (LAA) thrombosis increases the risk of stroke and its management has to be assessed. The aim of the present study is to evaluate short and long-term safety and efficacy of a standardized approach of percutaneous LAA closure (LAAC) routinely using a cerebral protection device (CPD) in patients with LAA thrombosis or sludge (LAAT). METHODS: We prospectively enrolled 14 consecutive patients with atrial fibrillation complicated by LAAT presenting in a high-volume tertiary center. In seven patients (50%) LAAT was found after anticoagulant withdrawal for severe bleedings and in the remaining half LAAT was found despite appropriate anticoagulant therapy. All patients were treated with a standardized interventional approach of LAAC routinely using a CPD and guided by transoesophageal echocardiography. RESULTS: Mean age was 68 ± 14 years and nine patients (64%) were male. Mean CHA2 DS2 -VASc and HAS-BLED scores were 3.3 ± 1.6 and 2.3 ± 1.1, respectively. Six patients (42.8%) presented organized thrombi while eight LAA sludge (57.1%). In 13 patients (92.8%) CPD was positioned through a right radial arterial access. Procedural success was achieved in all patients. In one patient we assisted to embolization of the thrombus during deployment of the device in the absence of neurological consequences. During a mean follow up of 426 ± 307 days, one patient died for non-cardiac cause while no embolic event or major bleeding were reported. CONCLUSION: In an unselected cohort, LAAC with the systematic use of CPD was a feasible, safe and effective therapeutic option for LAAT both acutely and after long-term follow-up.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Procedimientos Quirúrgicos Cardíacos , Dispositivos de Protección Embólica , Accidente Cerebrovascular/prevención & control , Trombosis/cirugía , Anciano , Ecocardiografía Transesofágica , Femenino , Humanos , Masculino , Estudios Prospectivos , Dispositivo Oclusor Septal
8.
Rev Cardiovasc Med ; 22(3): 597-611, 2021 Sep 24.
Artículo en Inglés | MEDLINE | ID: mdl-34565063

RESUMEN

Takotsubo syndrome (TTS) is an intriguing clinical entity, characterized by usually transient and reversible abnormalities of the left ventricular systolic function, mimicking the myocardial infarction with non-obstructive coronary arteries. TTS was initially regarded as a benign condition, however recent studies have unveiled adverse outcomes in the short- and long-term, with rates of morbidity and mortality comparable to those experienced after an acute myocardial infarction. Given the usual transient nature of TTS, this is an unexpected finding. Moreover, long-term mortality seems to be mainly driven by non-cardiovascular causes. The uncertain long-term prognosis of TTS warrants a comprehensive outpatient follow-up after the acute event, although there are currently no robust data indicating its modality and timing. The aim of the present review is to summarize recent available evidence regarding long-term prognosis in TTS. Moreover methods, timing and findings of the long-term management of TTS will be discussed.


Asunto(s)
Infarto del Miocardio , Cardiomiopatía de Takotsubo , Humanos , Pronóstico , Cardiomiopatía de Takotsubo/diagnóstico , Cardiomiopatía de Takotsubo/terapia , Función Ventricular Izquierda
9.
Europace ; 23(8): 1166-1178, 2021 08 06.
Artículo en Inglés | MEDLINE | ID: mdl-33382868

RESUMEN

Life-threatening refractory unstable ventricular arrhythmias in presence of advanced heart failure (HF) may determine haemodynamic impairment. Haemodynamic mechanical support (HMS) in this setting has a relevant role to restore end-organ perfusion. Catheter ablation (CA) of ventricular tachycardia (VT) is effective at achieving rhythm stabilization, allowing patient's weaning from HMS, or bridging to permanent HF treatments. Acute heart decompensation during CA at anaesthesia induction in presence of advanced heart disease, in selected cases requires a preemptive HMS to prevent periprocedure adverse outcomes. Substrate ablation during sinus rhythm (SR) might be an effective strategy of ablation in presence of unstable VTs; however, in a minority of patients, it might have some limitations and might be unfeasible in some settings, including the case of the mechanical induction of several unstable VTs and the absence of ablation targets. In case of the persistent induction of unstable VTs after a previous failure of a substrate-based ablation in SR, a feasible alternative strategy of ablation might be VT activation/entrainment mapping supported by HMS. Multiple devices are available for HMS in the low-output states related to electrical storm and during CA of VT. The choice of the device is not standardized and it is based on the centres' expertise. The aim of this article is to provide an up-to-date review on HMS for the management of life-threatening arrhythmias, in the context of catheter ablation and discussing our approach to manage critical VT patients.


Asunto(s)
Ablación por Catéter , Insuficiencia Cardíaca , Taquicardia Ventricular , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Hemodinámica , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Resultado del Tratamiento
10.
Pacing Clin Electrophysiol ; 44(8): 1449-1463, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34081333

RESUMEN

Premature ventricular complexes (PVCs) are increasingly recognized, as the use of ECG wearables becomes more widespread. In particular, PVCs arising from both the right ventricular outflow tract (RVOT) and left ventricular outflow tract (LVOT) comprise the majority of these arrhythmias and form a significant component of an electrophysiology practice. A keen understanding of the correlative anatomy of the outflow tracts, in addition to recognizing key ECG indices illustrating PVC sites of origin, are fundamental in preparing for a successful ablation. Patient selection, incorporating symptomatology, structural disease, and PVC burden can pose a challenge, though tools such as the ABC-VT risk score may help identify those patients with a higher risk of clinical deterioration. Utilizing intracardiac echocardiography to highlight salient anatomic features not visible with fluoroscopy allows for a more precise and safer ablation. Interpretation of intracardiac EGMs, and the careful examination for low amplitude highly fractionated pre-potentials, enhanced by the advent of new developed mapping/ablation catheters, remains crucial. Utilizing these tools will guide the electrophysiologist to an efficient and effective outflow tract PVC ablation.


Asunto(s)
Ecocardiografía/métodos , Electrocardiografía/métodos , Mapeo Epicárdico/métodos , Complejos Prematuros Ventriculares/diagnóstico , Ablación por Catéter , Humanos , Complejos Prematuros Ventriculares/fisiopatología , Complejos Prematuros Ventriculares/cirugía
11.
J Electrocardiol ; 58: 19-26, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31678717

RESUMEN

BACKGROUND: Recent evidence has shown that the presence of abnormal substrate can be demonstrated also among patients with "lone" AF. OBJECTIVES: Interatrial conduction slowing is likely to characterize patients with paroxysmal atrial fibrillation (AF) and it could be correlated to the left atrium area of prolonged local bipolar endocardial electrograms. METHODS: P-wave duration (PWD), amplified PWD and endocavitary interatrial conduction time (IACT), were analyzed in 60 patients; 30 undergoing de novo ablation for paroxysmal AF with normal atrial volumes and without any other cardiac disease and 30 of similar age undergoing electrophysiological study for atrioventricular nodal reentrant tachycardia or atrioventricular re- entrant tachycardia. In patients with AF, voltage maps and local bipolar electrograms (LBE) duration map were evaluated. RESULTS: Although PWD was <120 ms in 28 patients with AF and in 29 controls, patients with AF exhibited longer PWD, amplified-PWD and IACT. Although low-voltage areas (<0.5 mV) were not found in the study population, 28 of them demonstrated areas with LBE longer than 60 ms. These LBE were found mainly in the roof of the left atrium and their extension was correlated to IACT (R = 0.51, p = 0.004). IACT >135.5 ms identified the subjects who experienced AF with 90% sensitivity and 97% specificity. CONCLUSION: A subclinical interatrial conduction disturbance is demonstrable in subjects with paroxysmal AF and normal left atrial volume. IACT has a good correlation to the areas of abnormal LBE in the left atrium. IACT >135 ms identified subjects who have experienced AF.


Asunto(s)
Fibrilación Atrial , Taquicardia por Reentrada en el Nodo Atrioventricular , Fibrilación Atrial/diagnóstico , Electrocardiografía , Atrios Cardíacos/diagnóstico por imagen , Sistema de Conducción Cardíaco , Humanos
12.
J Interv Card Electrophysiol ; 67(2): 353-361, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37639157

RESUMEN

BACKGROUND: Ninety-watt applications are more sensitive to catheter instability and produce lesions that are shallower and smaller in diameter than 50-W applications. These characteristics were considered for the development of a combined (90-50 W) pulmonary vein isolation (PVI) strategy which was prospectively compared to a 50 W-only ablation index (AI)-guided PVI strategy. METHODS: One hundred fifty consecutive paroxysmal AF patients underwent PVI under general anesthesia using CARTO. In the first 75 patients, PVI was performed with a combined (90-50 W) strategy using the QDOT-MICRO catheter in a temperature-controlled mode. This strategy consisted of 90 W-4 s applications on the posterior LA wall (at sites of catheter stability and expectedly thin atrial tissue) with an interlesion distance (ILD) ≤ 4 mm and 50-W applications elsewhere (at sites of catheter instability or expectedly thick atrial tissue) with ILD < 6 mm. In the subsequent 75 patients, PVI was performed with a 50 W-only AI-guided strategy using the SmartTouch-SF catheter in a power-controlled mode. RESULTS: Both groups of patients had similar clinical characteristics and LA dimensions (123.1 ± 24.9 ml vs 119 ± 26.8 ml, P = 0.33). Total procedural times (61 [56-70] vs 65 [60-75] min, P = 0.12), first-pass PVI (82.6 vs 80%, P = 0.81), acute PV reconnection (0 vs 6.6%, P = 0.05), and 1-year SR maintenance (93.3 vs 90.6%, P = 0.57) rates were also similar in both groups of patients. There were no complications in the combined (90-50 W) group while only 2 groin hematomas were reported in the 50 W group. CONCLUSIONS: In paroxysmal AF patients, a combined (90-50 W) strategy for PVI did not improve safety, efficiency, or effectiveness compared to a 50 W-only AI-guided strategy.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Flujo de Trabajo , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Recurrencia
13.
J Interv Card Electrophysiol ; 67(6): 1365-1376, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38206451

RESUMEN

BACKGROUND: Catheter ablation of persistent atrial fibrillation (PsAF) represents a challenge for the electrophysiologist and there are still divergences regarding the best ablative approach to adopt. Create a new map of the duration of atrial bipolar electrograms (Atrial Electrogram DUration Map, AEDUM) to recognize a functional substrate during sinus rhythm and guide a patient-tailored ablative strategy for PsAF. METHODS: Forty PsAF subjects were assigned in a 1:1 ratio to either for PVI alone (Group B1) or PVI+AEDUM areas ablation (Group B2). A cohort of 15 patients without AF history undergoing left-sided accessory pathway ablation was used as a control group (Group A). In all patients, voltage and AEDUM maps were created during sinus rhythm. The minimum follow-up was 12 months, with rhythm monitoring via 48-h ECG Holter or by implantable cardiac device. RESULTS: Electrogram (EGM) duration was higher in Group B than in Group A (49±16.2ms vs 34.2±3.8ms; p-value<0.001). In Group B the mean cumulative AEDUM area was 21.8±8.2cm2; no difference between the two subgroups was observed (22.3±9.1cm2 vs 21.2±7.2cm2; p-value=0.45). The overall bipolar voltage recorded inside the AEDUM areas was lower than in the remaining atrial areas [median: 1.30mV (IQR: 0.71-2.38mV) vs 1.54mV (IQR: 0.79-2.97mV); p-value: <0.001)]. Low voltage areas (<0.5mV) were recorded in three (7.5%) patients in Group B. During the follow-up [median 511 days (376-845days)] patients who underwent PVI-only experienced more AF recurrence than those receiving a tailored approach (65% vs 35%; p-value= 0.04). CONCLUSIONS: All PsAF patients exhibited AEDUM areas. An ablation approach targeting these areas resulted in a more effective strategy compared with PVI only.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Masculino , Femenino , Ablación por Catéter/métodos , Proyectos Piloto , Persona de Mediana Edad , Resultado del Tratamiento , Mapeo del Potencial de Superficie Corporal/métodos , Electrocardiografía Ambulatoria/métodos
14.
Eur Heart J Cardiovasc Imaging ; 24(8): 1082-1091, 2023 07 24.
Artículo en Inglés | MEDLINE | ID: mdl-36861644

RESUMEN

AIMS: myocardial oedema is largely represented in takotsubo syndrome (TTS) and may contribute to alter the myocardium morphology and function. The aim of the study is to describe relationships between oedema, mechanical, and electrical abnormalities in TTS. METHODS AND RESULTS: the study included n = 32 hospitalized TTS patients and n = 23 controls. Cardiac magnetic resonance (CMR) with tissue mapping and feature tracking was performed with concomitant 12-lead electrocardiogram (ECG) recording. Mean age of TTS was 72 ± 12 years old, 94% women. Compared with controls, patients had higher left ventricular (LV) mass, worse systolic function, higher septal native T1 (1116 ± 73 msec vs. 970 ± 23 msec, P < 0.001), T2 (56 ± 5 msec vs. 46 ± 2 msec, P < 0.001), and extracellular volume (ECV) fraction (32 ± 5% vs. 24 ± 1%, P < 0.001). TTS patients had higher apicobasal gradient of T2 values (12 ± 6 msec vs. 2 ± 6 msec, P < 0.001); basal LV wall displayed higher native T1, T2, and ECV (all P < 0.002) but similar circumferential strain against controls (-23 ± 3% vs. -24 ± 4%, P = 0.351). In the TTS cohort, septal T2 values showed significant correlations with native T1 (r = 0.609, P < 0.001), ECV (r = 0.689, P < 0.001), left ventricular ejection fraction (r = -0.459, P = 0.008) and aVR voltage (r = -0.478, P = 0.009). Negative T-wave voltage and QTc length correlated with apicobasal T2 mapping gradient (r = 0.499, P = 0.007 and r = 0.372, P = 0.047, respectively) but not with other tissue mapping measurements. CONCLUSIONS: CMR T1 and T2 mapping demonstrated increased myocardial water content conditioning interstitial expansion in acute TTS, detected even outside areas of abnormal wall motion. Oedema burden and distribution associated with mechanical and electrocardiographic changes, making it a potential prognostic marker and therapeutic target in TTS.


Asunto(s)
Cardiomiopatía de Takotsubo , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Cardiomiopatía de Takotsubo/diagnóstico por imagen , Volumen Sistólico , Función Ventricular Izquierda , Imagen por Resonancia Cinemagnética/métodos , Miocardio/patología , Espectroscopía de Resonancia Magnética , Edema/diagnóstico por imagen , Edema/patología , Valor Predictivo de las Pruebas , Medios de Contraste
15.
Heart Rhythm ; 19(12): 2075-2083, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35964871

RESUMEN

BACKGROUND: Abnormal ventricular signals (AVS) are the cornerstone of substrate-based ventricular tachycardia (VT) ablation in sinus rhythm. Signal characterization of AVS in ischemic and nonischemic cardiomyopathies has never been performed. OBJECTIVE: The purpose of this study was to describe ventricular signal abnormalities in 3 different pathologies and examine their association with the diastolic component of VT circuits. METHODS: A total of 45 patients (15 ischemic cardiomyopathy [ICM], 15 arrhythmogenic cardiomyopathy [ACM], 15 dilated cardiomyopathy [DCM]) who had undergone VT ablation with >50% of the diastolic pathway of the VT circuit recorded were studied. AVS were classified into late potentials (LPs) and continuous fractionated ventricular signals (CFVS), and their characteristics and correlation with the diastolic pathway of VT circuits were analyzed. RESULTS: Seventy-five VT circuits were analyzed. Bipolar scars were greatest in ICM endocardially (53 cm2 ICM vs 36 cm2 ACM vs 25 cm2 DCM; P = .010) and in ACM epicardially (98 cm2 ACM vs 25 cm2 ICM vs 24 cm2 DCM; P = .005). Location of the VT diastolic interval coincided with AVS location in 54% of VTs in ICM, 89% in ACM, and 72% in DCM (P = .036). There was a trend toward a greater association of diastolic intervals coinciding with LPs than with CFVS (78% vs 57%; P = .052) (69% diastolic intervals in ICM coincided with LPs, 33% with CFVS; P = .063). All patients (100%) with CFVS in ACM had VT diastolic components arising from CFVS (33% ICM, 64% DCM; P = .049). Positive predictive value for LPs vs CFVS was 77.8% vs 56.7%, and sensitivity was 67.3% vs 32.7%, respectively. CONCLUSION: The nature of abnormal signals in different cardiomyopathies reflects underlying pathology. LPs rather than CFVS seem to be more linked to diastolic components of VT circuits, especially in ICM. LPs have greater sensitivity and specificity for VT; however, CFVS may be of more relevance in ACM.


Asunto(s)
Cardiomiopatías , Cardiomiopatía Dilatada , Ablación por Catéter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía , Lipopolisacáridos , Resultado del Tratamiento , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico , Cardiomiopatía Dilatada/complicaciones , Cardiomiopatía Dilatada/diagnóstico , Cardiomiopatía Dilatada/cirugía
16.
JACC Clin Electrophysiol ; 8(5): 561-577, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35589168

RESUMEN

OBJECTIVES: This study aimed to evaluate the progression of electrophysiological phenomena in a cohort of patients with paroxysmal atrial fibrillation (PAF) and persistent atrial fibrillation (PsAF). BACKGROUND: Electrical remodeling has been conjectured to determine atrial fibrillation (AF) progression. METHODS: High-density electroanatomic maps during sinus rhythm of 20 patients with AF (10 PAF, 10 PsAF) were compared with 5 healthy control subjects (subjects undergoing ablation of a left-sided accessory pathway). A computational postprocessing of electroanatomic maps was performed to identify specific electrophysiological phenomena: slow conductions corridors, defined as discrete areas of conduction velocity <50 cm/s, and pivot points, defined as sites showing high wave-front curvature documented by a curl module >2.5 1/s. RESULTS: A progressive decrease of mean conduction velocity was recorded across the groups (111.6 ± 55.5 cm/s control subjects, 97.1 ± 56.3 cm/s PAF, and 84.7 ± 55.7 cm/s PsAF). The number and density of slow conduction corridors increase in parallel with the progression of AF (8.6 ± 2.2 control subjects, 13.3 ± 3.2 PAF, and 20.5 ± 4.5 PsAF). In PsAF the atrial substrate is characterized by a higher curvature of wave-front propagation (0.86 ± 0.71 1/s PsAF vs 0.74 ± 0.63 1/s PAF; P = 0.003) and higher number of pivot points (25.1 ± 13.8 PsAF vs 9.5 ± 6.7 PAF; P < 0.0001). Slow conductions: corridors were mostly associated with pivot sites tending to cluster around pulmonary veins antra. CONCLUSIONS: The electrical remodeling hinges mainly on corridors of slow conduction and higher curvature of wave-front propagation. Pivot points associated to SC corridors may be the major determinants for functional localized re-entrant circuits creating the substrate for maintenance of AF.


Asunto(s)
Fibrilación Atrial , Remodelación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/cirugía , Atrios Cardíacos , Humanos , Venas Pulmonares/cirugía
17.
G Ital Cardiol (Rome) ; 23(2): 120-127, 2022 Feb.
Artículo en Italiano | MEDLINE | ID: mdl-35343516

RESUMEN

BACKGROUND: Transvenous pacing is nowadays the cornerstone of interventional management of bradyarrhythmias. It is still associated, however, with significant complications, mostly related to indwelling transvenous leads or device pocket. In order to reduce these complications, leadless pacemakers have been recently introduced into clinical practice, but no guidelines are yet available to indicate who are those patients that might benefit the most and whether leadless pacing should be preferred in the old or young population. This survey aims to describe the use of leadless pacemaker devices in a real-world setting. METHODS: Eleven arrhythmia centers in the Lombardy region (out of a total of 17 participating centers) responded to the proposed questionnaire regarding patient characteristics and indications to leadless pacing. RESULTS: Out of a total of 411 patients undergoing leadless pacing during 4.2 ± 0.98 years, the median age was 77 years, with 0.18% of patients having less than 18 years, 29.9% 18-65 years, 34.3% 65-80 years and 35.6% >80 years. The most common indication was slow atrial fibrillation (49% of patients), followed by atrioventricular block and sinoatrial dysfunction. Two centers reported in-hospital complications. CONCLUSIONS: Leadless pacemakers proved to be a safe pacing strategy actually destined mostly to elderly patients.


Asunto(s)
Fibrilación Atrial , Bloqueo Atrioventricular , Marcapaso Artificial , Anciano , Bloqueo Atrioventricular/terapia , Diseño de Equipo , Humanos , Encuestas y Cuestionarios
18.
Int J Cardiol ; 329: 23-27, 2021 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-33359286

RESUMEN

BACKGROUND: Research investigating takotsubo syndrome (TTS) recurrence yielded conflicting results. Aim of the present study is to describe clinical characteristics of patients with TTS recurrence in a cohort with available long-term follow-up. METHODS: The study population included 234 TTS patients enrolled in a prospective multicenter registry, median follow-up of 1328 (407, 2526) days. To investigate factors associated with TTS recurrence, we analyzed patients with recurrence (Group A) in comparison with a subgroup of TTS patients within the whole population (group B) who had similar age, sex and median follow-up length (Group A 2280 days vs Group B 2361 days). RESULTS: We observed 9 TTS recurrences affecting 8 patients, all women, with a rate of 0.9% patients/year. Median time to first recurrence was 1593 days (interquartile range: 950, 2516). We detected no significant differences between patients with and without recurrences regarding cardiovascular risk factors, symptoms, ECG and echocardiographic findings at presentation, discharge therapy. Physical trigger and chronic obstructive pulmonary disease (COPD) were more prevalent in patients who experienced a recurrence (75% vs 27% and 50% vs 14% with p = 0.01 and p = 0.022 respectively). Univariable Cox regression analysis identified physical trigger and history of COPD to be both associated with TTS recurrence [hazard ratio (HR) 11.4, 95% confidence interval (CI) 2.29-56.8, p = 0.003 and HR 4.94, 95% CI 1.16-20.99 p = 0.031 respectively]. CONCLUSION: TTS recurrence is relatively uncommon. Association with physical trigger and COPD would suggest a closer follow-up in this subgroup of patients.


Asunto(s)
Cardiomiopatía de Takotsubo , Femenino , Estudios de Seguimiento , Humanos , Estudios Prospectivos , Recurrencia , Sistema de Registros , Cardiomiopatía de Takotsubo/diagnóstico por imagen , Cardiomiopatía de Takotsubo/epidemiología
19.
Front Cardiovasc Med ; 8: 703418, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34485402

RESUMEN

Takotsubo syndrome (TTS) is an increasingly recognized condition burdened by significant acute and long-term adverse events. The availability of novel techniques expanded the knowledge on TTS and allowed a more accurate risk-stratification, potentially guiding clinical management. The present review aims to summarize the recent advances in TTS prognostic evaluation with a specific focus on novel imaging and genetic markers. Parametric deformation analysis by speckle-tracking echocardiography, as well as tissue characterization by cardiac magnetic resonance imaging T1 and T2 mapping techniques, currently appear the most clinically valuable applications. Notwithstanding, computed tomography and nuclear imaging studies provided limited but promising data. A genetic predisposition to TTS has been hypothesized, though available evidence is still not sufficient. Although a genetic predisposition appears likely, further studies are needed to fully characterize the genetic background of TTS, in order to identify genetic markers that could assist in predicting disease recurrences and help in familial screening.

20.
J Clin Med ; 10(9)2021 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-34063260

RESUMEN

BACKGROUND: Optimal antithrombotic therapy after left atrial appendage (LAA) occlusion is still not clear. The aim of this study was to investigate the role of different antithrombotic regimens after the procedure. METHODS AND RESULTS: We retrospectively analyzed data of 260 patients who underwent LAA occlusion and divided them into four groups according to therapy at discharge: dual antiplatelet therapy (group A, 71.5%); oral anticoagulants (group B, 19%); "minimal" antithrombotic therapy (single antiplatelet agent or without any antithrombotic therapy; group C, 4.5%) and other therapeutic regimens (such as a combination of antiplatelets and anticoagulants; group D, 4.5%). We analyzed baseline characteristics, procedural data, and clinical and transesophageal follow-up for each group. The incidence of adverse events was low in the whole population and had a similar distribution among groups. The majority of bleeding events was registered during the first 3 months after the procedure (34 out of 46, 70%). Ischemic events (2%), as well as silent left atrial thrombosis, were rare and not significantly higher in the population discharged with "minimal" antithrombotic therapy. CONCLUSION: Our experience seems to suggest that LAA occlusion was associated with a low incidence of adverse events, regardless of antithrombotic therapy. A "minimal" drug regimen may be feasible without losing efficacy on embolic prevention for patients with high bleeding risk.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA