1.
J Appl Clin Med Phys ; 17(1): 387-395, 2016 01 08.
Artículo en Inglés | MEDLINE | ID: mdl-26894365

RESUMEN

Proper quality assurance (QA) of the radiotherapy process can be time-consuming and expensive. Many QA efforts, such as data export and import, are inefficient when done by humans. Additionally, humans can be unreliable, lose attention, and fail to complete critical steps that are required for smooth operations. In our group we have sought to break down the QA tasks into separate steps and to automate those steps that are better done by software running autonomously or at the instigation of a human. A team of medical physicists and software engineers worked together to identify opportunities to streamline and automate QA. Development efforts follow a formal cycle of writing software requirements, developing software, testing and commissioning. The clinical release process is separated into clinical evaluation testing, training, and finally clinical release. We have improved six processes related to QA and safety. Steps that were previously performed by humans have been automated or streamlined to increase first-time quality, reduce time spent by humans doing low-level tasks, and expedite QA tests. Much of the gains were had by automating data transfer, implementing computer-based checking and automation of systems with an event-driven framework. These coordinated efforts by software engineers and clinical physicists have resulted in speed improvements in expediting patient-sensitive QA tests.


Asunto(s)
Procesamiento Automatizado de Datos/normas , Neoplasias/radioterapia , Reconocimiento de Normas Patrones Automatizadas/métodos , Garantía de la Calidad de Atención de Salud/normas , Planificación de la Radioterapia Asistida por Computador/normas , Programas Informáticos , Humanos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos
2.
ArXiv ; 2024 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-37292473

RESUMEN

Background: FLASH Radiotherapy (RT) is an emergent cancer radiotherapy modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: 1) large area coverage; 2) a low mass profile; 3) a linear response over a broad dynamic range; 4) radiation hardness; 5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation do-simetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ~10 cm. A field programmable gate array (FPGA) data acquisition system (DAQ) generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100-1000 Hz for pulsed electrons and 10-20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams (86Kr+26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital radiotherapy clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. The HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 minutes at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude vs beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of > 40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35-40 µm. Tests of the firmware beta version show successful operation at 20,000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥ 50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

3.
Med Phys ; 51(4): 2905-2923, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38456622

RESUMEN

BACKGROUND: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. PURPOSE: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. METHODS: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100-1000 Hz for pulsed electrons and 10-20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams (86Kr+26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. RESULTS: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. The HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35-40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. CONCLUSIONS: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.


Asunto(s)
Protones , Radiometría , Cintigrafía , Dosificación Radioterapéutica
4.
Artículo en Inglés | MEDLINE | ID: mdl-38844140

RESUMEN

PURPOSE: For men with intermediate-risk prostate cancer treated with definitive therapy, the addition of androgen deprivation therapy (ADT) reduces the risk of distant metastasis and cancer-related mortality. However, the absolute benefit of ADT varies by baseline cancer risk. Estimates of prognosis have improved over time, and little is known about ADT decision making in the modern era. We sought to characterize variability and identify factors associated with intended ADT use within the Michigan Radiation Oncology Quality Consoritum (MROQC). MATERIALS AND METHODS: Patients with localized prostate cancer undergoing definitive radiation therapy were enrolled from June 9, 2020, to June 26, 2023 (n = 815). Prospective data were collected using standardized patient, physician, and physicist forms. Intended ADT use was prospectively defined and was the primary outcome. Associations with patient, tumor, and practice-related factors were tested with multivariable analyses. Random intercept modeling was used to estimate facility-level variability. RESULTS: Five hundred seventy patients across 26 facilities were enrolled with intermediate-risk disease. ADT was intended for 46% of men (n = 262/570), which differed by National Comprehensive Cancer Network favorable intermediate-risk (23.5%, n = 38/172) versus unfavorable intermediate-risk disease (56.3%, n = 224/398; P < .001). After adjusting for the statewide case mix, the predicted probability of intended ADT use varied significantly across facilities, ranging from 15.4% (95% CI, 5.4%-37.0%) to 71.7% (95% CI, 57.0%-82.9%), with P < .01. Multivariable analyses showed that grade group 3 (OR, 4.60 [3.20-6.67]), ≥50% positive cores (OR, 2.15 [1.43-3.25]), and prostate-specific antigen 10 to 20 (OR, 1.87 [1.24-2.84]) were associated with ADT use. Area under the curve was improved when incorporating MRI adverse features (0.76) or radiation treatment variables (0.76), but there remained significant facility-level heterogeneity in all models evaluated (P < .05). CONCLUSIONS: Within a state-wide consortium, there is substantial facility-level heterogeneity in intended ADT use for men with intermediate-risk prostate cancer. Future efforts are necessary to identify patients who will benefit most from ADT and to develop strategies to standardize appropriate use.

5.
Adv Radiat Oncol ; 7(1): 100768, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35071827

RESUMEN

PURPOSE: Due to a gap in published guidance, we describe our robust cycle of in-house clinical software development and implementation, which has been used for years to facilitate the safe treatment of all patients in our clinics. METHODS AND MATERIALS: Our software development and implementation cycle requires clarity in communication, clearly defined roles, thorough commissioning, and regular feedback. Cycle phases include design requirements and use cases, development, physics evaluation testing, clinical evaluation testing, and full clinical release. Software requirements, release notes, test suites, and a commissioning report are created and independently reviewed before clinical use. Software deemed to be high-risk, such as those that are writable to a database, incorporate the use of a formal, team-based hazard analysis. Incident learning is used to both guide initial development and improvements as well as to monitor the safe use of the software. RESULTS: Our standard process builds in transparency and establishes high expectations in the development and use of custom software to support patient care. Since moving to a commercial planning system platform in 2013, we have applied our team-based software release process to 16 programs related to scripting in the treatment planning system for the clinic. CONCLUSIONS: The principles and methodology described here can be implemented in a range of practice settings regardless of whether or not dedicated resources are available for software development. In addition to teamwork with defined roles, documentation, and use of incident learning, we strongly recommend having a written policy on the process, using phased testing, and incorporating independent oversight and approval before use for patient care. This rigorous process ensures continuous monitoring for and mitigatation of any high risk hazards.

6.
J Appl Clin Med Phys ; 12(3): 3398, 2011 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-21844848

RESUMEN

The purpose of this study was to determine the dosimetric impact of density variations observed in water-equivalent solid slabs. Measurements were performed using two 30 cm × 30 cm water-equivalent slabs, one being 4 cm think and the other 5 cm thick. The location and extent of density variations were determined by computed tomography (CT) scans. Additional imaging measurements were made with an amorphous silicon megavoltage portal imaging device and an ultrasound unit. Dosimetric measurements were conducted with a 2D ion chamber array, and a scanned diode in water. Additional measurements and calculations were made of small rectilinear void inhomogeneities formed with water-equivalent slabs, using a 2D ion chamber array and the convolution superposition algorithm. Two general types of density variation features were observed on CT images: 1) regions of many centimeters across, but typically only a few millimeters thick, with electron densities a few percent lower than the bulk material, and 2) cylindrical regions roughly 0.2 cm in diameter and up to 20 cm long with electron densities up to 5% lower than the surrounding material. The density variations were not visible on kilovoltage, megavoltage or ultrasound images. The dosimetric impact of the density variations were not detectable to within 0.1% using the 2D ion chamber array or the scanning photon diode at distances 0.4 cm to 2 cm beyond the features. High-resolution dosimetric calculations using the convolution-superposition algorithm with density corrections enabled on CT-based datasets showed no discernable dosimetric impact. Calculations and measurements on simulated voids place the upper limit on possible dosimetric variations from observed density variations at much less than 0.6%. CT imaging of water-equivalent slabs may reveal density variations which are otherwise unobserved with kV, MV, or ultrasound imaging. No dosimetric impact from these features was measureable with an ion chamber array or scanned photon diode. Consequently, they were determined to be acceptable for all clinical use.


Asunto(s)
Fotones , Radiometría/métodos , Agua/química , Algoritmos , Humanos , Iones , Fantasmas de Imagen , Efectos de la Radiación , Radiometría/instrumentación , Radioterapia de Alta Energía , Silicio/química , Tomografía Computarizada por Rayos X , Ultrasonografía , Pantallas Intensificadoras de Rayos X
7.
Med Phys ; 48(10): 6137-6151, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34431520

RESUMEN

PURPOSE: Electron-based ultra-high dose rate radiation therapy (UHDR-RT), also known as Flash-RT, has shown the ability to improve the therapeutic index in comparison to conventional radiotherapy (CONV-RT) through increased sparing of normal tissue. However, the extremely high dose rates in UHDR-RT have raised the need for accurate real-time dosimetry tools. This work aims to demonstrate the potential of the emerging technology of Ionized Radiation Acoustic Imaging (iRAI) through simulation studies and investigate its characteristics as a promising relative in vivo dosimetric tool for UHDR-RT. METHODS: The detection of induced acoustic waves following a single UHDR pulse of a modified 6 MeV 21EX Varian Clinac in a uniform porcine gelatin phantom that is brain-tissue equivalent was simulated for an ideal ultrasound transducer. The full 3D dose distributions in the phantom for a 1 × 1 cm2 field were simulated using EGSnrc (BEAMnrc∖DOSXYZnrc) Monte Carlo (MC) codes. The relative dosimetry simulations were verified with dose experimental measurements using Gafchromic films. The spatial dose distribution was converted into an initial pressure source spatial distribution using the medium-dependent dose-pressure relation. The MATLAB-based toolbox k-Wave was then used to model the propagation of acoustic waves through the phantom and perform time-reversal (TR)-based imaging reconstruction. The effect of the various linear accelerator (linac) operating parameters, including linac pulse duration and pulse repetition rate (frequency), were investigated as well. RESULTS: The MC dose simulation results agreed with the film measurement results, specifically at the central beam region up to 80% dose within approximately 5% relative error for the central profile region and a local relative error of <6% for percentage dose depth. IRAI-based FWHM of the radiation beam was within approximately 3 mm relative to the MC-simulated beam FWHM at the beam entrance. The real-time pressure signal change agreed with the dose changes proving the capability of the iRAI for predicting the beam position. IRAI was tested through 3D simulations of its response to be based on the temporal changes in the linac operating parameters on a dose per pulse basis as expected theoretically from the pressure-dose proportionality. The pressure signal amplitude obtained through 2D simulations was proportional to the dose per pulse. The instantaneous pressure signal amplitude decreases as the linac pulse duration increases, as predicted from the pressure wave generation equations, such that the shorter the linac pulse the higher the signal and the better the temporal (spatial) resolutions of iRAI. The effect of the longer linac pulse duration on the spatial resolution of the 3D constructed iRAI images was corrected for linac pulse deconvolution. This correction has improved the passing rate of the 1%/1 mm gamma test criteria, between the pressure-constructed and dosimetric beam characteristics, to as high as 98%. CONCLUSIONS: A full simulation workflow was developed for testing the effectiveness of iRAI as a promising relative dosimetry tool for UHDR-RT radiation therapy. IRAI has shown the advantage of 3D dose mapping through the dose signal linearity and, hence, has the potential to be a useful dosimeter at depth dose measurement and beam localization and, hence, potentially for in vivo dosimetry in UHDR-RT.


Asunto(s)
Aceleradores de Partículas , Radiometría , Acústica , Animales , Método de Montecarlo , Fantasmas de Imagen , Radiación Ionizante , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Porcinos
8.
Med Phys ; 45(4): 1369-1378, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29474748

RESUMEN

PURPOSE: Investigate the impact on prostate orientation caused by use and removal of a Foley catheter, and the dosimetric impact on men prospectively treated with prostate stereotactic body radiotherapy (SBRT). METHODS: Twenty-two men underwent a CT simulation with a Foley in place (FCT), followed immediately by a second treatment planning simulation without the Foley (TPCT). The change in prostate orientation was determined by rigid registration of three implanted transponders between FCT and TPCT and compared to measured orientation changes during treatment. The impact on treatment planning and delivery was investigated by analyzing the measured rotations during treatment relative to both CT scans, and introducing rotations of ±15° in the treatment plan to determine the maximum impact of allowed rotations. RESULTS: Removing the Foley caused a statistically significant prostate rotation (P < 0.0028) compared to normal biological motion in 60% of patients. The largest change in rotation due to removing a Foley occurs about the left-right axis (tilt) which has a standard deviation two to five times larger than changes in rotation about the Sup-Inf (roll) and Ant-Post (yaw) axes. The change in tilt due to removing a Foley for prone and supine patients was -1.1° ± 6.0° and 0.3° ± 7.4°, showing no strong directional bias. The average tilt during treatment was -1.6° ± 7.1° compared to the TPCT and would have been -2.0° ± 7.1° had the FCT been used as the reference. The TPCT was a better or equivalent representation of prostate tilt in 82% of patients, vs 50% had the FCT been used for treatment planning. However, 92.7% of fractions would still have been within the ±15° rotation limit if only the FCT were used for treatment planning. When rotated ±15°, urethra V105% = 38.85Gy  < 20% was exceeded in 27% of the instances, and prostate (CTV) coverage was maintained above D95%  > 37 Gy in all but one instance. CONCLUSIONS: Removing a Foley catheter can cause large prostate rotations. There does not appear to be a clear dosimetric benefit to obtaining the CT scan with a Foley catheter to define the urethra given the changes in urethral position from removing the Foley catheter. If urethral sparing is desired without the use of a Foley, utilization of an MRI to define the urethra may be necessary, or a pseudo-urethral planning organ at risk volume (PRV) may be used to limit dosimetric hot spots.


Asunto(s)
Artefactos , Catéteres , Movimiento , Neoplasias de la Próstata/radioterapia , Radiocirugia , Ensayos Clínicos como Asunto , Humanos , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/fisiopatología , Radiometría , Planificación de la Radioterapia Asistida por Computador , Rotación , Tomografía Computarizada por Rayos X/instrumentación
9.
Pract Radiat Oncol ; 8(1): 40-47, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29304991

RESUMEN

PURPOSE: The use of stereotactic body radiation therapy (SBRT) for prostate cancer has been reported predominantly from single institutional studies, although concerns for broader adoption exist. METHODS AND MATERIALS: From 2011 through 2013, 66 men were accrued to a phase 2 trial at 5 centers. SBRT consisted of 5 fractions of 7.4 Gy to a total dose of 37 Gy using conventional linear accelerators. Electromagnetic transponders were used for motion management. Health-related quality of life (HRQOL) was evaluated via the Expanded Prostate Cancer Index Composite 26 questionnaire. Acute and late toxicities were collected according to Common Terminology Criteria for Adverse Events, version 4.0. Linear mixed modeling was performed to assess changes in HRQOL over time. RESULTS: Median follow-up was 36 months. All men had low- or intermediate-risk disease. There have been 0 biochemical recurrences. No grade 3 urinary or bowel toxicity was reported. Twenty-three percent of patients had acute grade 2 urinary toxicity, with 9% late grade 2 urinary toxicity. Four percent and 5% experienced acute or late grade 2+ bowel toxicity, respectively. Urinary bother and bowel HRQOL transiently decreased during the first 6 to 12 months post-SBRT, and then returned to baseline. In men with good erectile function at baseline, sexual HRQOL declined during the first 6 months and stabilized thereafter. On linear mixed modeling, the strongest predictor of sustained bowel and sexual HRQOL was baseline HRQOL. CONCLUSIONS: In this multi-institutional phase 2 clinical trial using continuous real-time evaluation of prostate motion, prostate SBRT has excellent intermediate-term tumor control with mild and expected treatment-related side effects.


Asunto(s)
Próstata/patología , Neoplasias de la Próstata/radioterapia , Radiocirugia/métodos , Anciano , Anciano de 80 o más Años , Humanos , Masculino , Persona de Mediana Edad , Calidad de Vida
10.
Int J Radiat Oncol Biol Phys ; 68(4): 1199-206, 2007 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-17513060

RESUMEN

PURPOSE: To determine the relative positional stability of implanted glass-encapsulated circuits (transponders) used in continuous electromagnetic localization and tracking of target volumes during radiation therapy. Ideally, the distances between transponders remains constant over the course of treatment. In this work, we evaluate the accuracy of these conditions. METHODS AND MATERIALS: Three transponders were implanted in each of 20 patients. Images (CT scan or X-ray pair) were acquired at 13 time points. These images occurred from the day of implant (2 weeks before simulation) to 4 weeks posttreatment. The distance between transponders was determined from each dataset. The average and standard deviation of each distance were determined, and changes were evaluated over several time periods, including pretreatment and during therapy. RESULTS: Of 60 transponders implanted, 58 showed no significant migration from their intended positions. Of the two transponders that did migrate, one appears to have been implanted in the venous plexus, and the other in the urethra, with no clinical consequences to the patients. An analysis that included the planning CT scan and all subsequent distance measurements showed that the standard deviation of intertransponder distances was < or =1.2 mm for up to 1 month after the completion of therapy. CONCLUSIONS: Implanted transponders demonstrate the same long-term stability characteristics as implanted gold markers, within statistical uncertainties. As with gold markers, and using the same implant procedure, basic guidelines for the placement of transponders within the prostate help ensure minimal migration.


Asunto(s)
Fenómenos Electromagnéticos/instrumentación , Neoplasias de la Próstata/radioterapia , Prótesis e Implantes/normas , Radioterapia Conformacional/instrumentación , Anciano , Anciano de 80 o más Años , Migración de Cuerpo Extraño , Humanos , Masculino , Persona de Mediana Edad , Próstata , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Dosis de Radiación , Radiografía , Radioterapia Conformacional/normas