Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Europace ; 25(7)2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37433034

RESUMEN

AIMS: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a progressive inherited cardiac disease. Early detection of disease and risk stratification remain challenging due to heterogeneous phenotypic expression. The standard configuration of the 12 lead electrocardiogram (ECG) might be insensitive to identify subtle ECG abnormalities. We hypothesized that body surface potential mapping (BSPM) may be more sensitive to detect subtle ECG abnormalities. METHODS AND RESULTS: We obtained 67 electrode BSPM in plakophilin-2 (PKP2)-pathogenic variant carriers and control subjects. Subject-specific computed tomography/magnetic resonance imaging based models of the heart/torso and electrode positions were created. Cardiac activation and recovery patterns were visualized with QRS- and STT-isopotential map series on subject-specific geometries to relate QRS-/STT-patterns to cardiac anatomy and electrode positions. To detect early signs of functional/structural heart disease, we also obtained right ventricular (RV) echocardiographic deformation imaging. Body surface potential mapping was obtained in 25 controls and 42 PKP2-pathogenic variant carriers. We identified five distinct abnormal QRS-patterns and four distinct abnormal STT-patterns in the isopotential map series of 31/42 variant carriers. Of these 31 variant carriers, 17 showed no depolarization or repolarization abnormalities in the 12 lead ECG. Of the 19 pre-clinical variant carriers, 12 had normal RV-deformation patterns, while 7/12 showed abnormal QRS- and/or STT-patterns. CONCLUSION: Assessing depolarization and repolarization by BSPM may help in the quest for early detection of disease in variant carriers since abnormal QRS- and/or STT-patterns were found in variant carriers with a normal 12 lead ECG. Because electrical abnormalities were observed in subjects with normal RV-deformation patterns, we hypothesize that electrical abnormalities develop prior to functional/structural abnormalities in ARVC.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica , Placofilinas , Humanos , Placofilinas/genética , Mapeo del Potencial de Superficie Corporal , Electrocardiografía/métodos , Ecocardiografía , Ventrículos Cardíacos , Displasia Ventricular Derecha Arritmogénica/diagnóstico , Displasia Ventricular Derecha Arritmogénica/genética
2.
J Electrocardiol ; 76: 55-60, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36436475

RESUMEN

INTRODUCTION: Inherited cardiomyopathies are associated with a broad spectrum of potentially lethal phenotypes characterized by structural and electrical myocardial remodeling. Increased awareness and genetic cascade screening lead to more genotype-positive, yet phenotype-negative individuals to be evaluated and followed up. The predictive value of genetic testing is hampered by incomplete penetrance and high variability in disease onset, progression and severity. CLINICAL CHALLENGES: Dilated cardiomyopathy usually manifests with symptoms of heart failure and ventricular arrhythmias (VA) develop in advanced disease. In arrhythmogenic cardiomyopathy (ACM), electrical remodeling can precede structural and functional changes and life-threatening VA can be the first disease manifestation. Early signs and symptoms may be subtle and go unnoticed. Physicians are in great need of appropriate screening and risk-stratification strategies. Task Force Criteria (TFC) were established to standardize the clinical diagnosis of ACM but risk-stratification remains challenging. Accurate prediction of disease progression in variation carriers is currently beyond the capabilities of diagnostic tests. PROPOSED DIAGNOSTIC TECHNIQUES: We propose three ECG-based techniques; isopotential mapping, inverse ECG and CineECG, to enhance risk-stratification in ACM. With the use of isopotential mapping abnormal spatio-temporal activation and repolarization may be identified. Furthermore, by combining subject specific ≥12­lead ECG data with cardiothoracic imaging using inverse ECG techniques, the direct link between ECG and cardiac anatomy can be obtained. CONCLUSION: New ECG techniques may prove more sensitive to detect early de- and repolarization abnormalities in yet asymptomatic variation carriers. Early electrical signs of disease progression may be identified prior to symptoms. Furthermore, individualized risk-stratification may be enhanced.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica , Cardiomiopatías , Humanos , Electrocardiografía , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/genética , Progresión de la Enfermedad , Manejo de la Enfermedad , Displasia Ventricular Derecha Arritmogénica/diagnóstico
3.
Europace ; 24(10): 1645-1654, 2022 10 13.
Artículo en Inglés | MEDLINE | ID: mdl-35762524

RESUMEN

AIMS: While electrocardiogram (ECG) characteristics have been associated with life-threatening ventricular arrhythmias (LTVA) in dilated cardiomyopathy (DCM), they typically rely on human-derived parameters. Deep neural networks (DNNs) can discover complex ECG patterns, but the interpretation is hampered by their 'black-box' characteristics. We aimed to detect DCM patients at risk of LTVA using an inherently explainable DNN. METHODS AND RESULTS: In this two-phase study, we first developed a variational autoencoder DNN on more than 1 million 12-lead median beat ECGs, compressing the ECG into 21 different factors (F): FactorECG. Next, we used two cohorts with a combined total of 695 DCM patients and entered these factors in a Cox regression for the composite LTVA outcome, which was defined as sudden cardiac arrest, spontaneous sustained ventricular tachycardia, or implantable cardioverter-defibrillator treated ventricular arrhythmia. Most patients were male (n = 442, 64%) with a median age of 54 years [interquartile range (IQR) 44-62], and median left ventricular ejection fraction of 30% (IQR 23-39). A total of 115 patients (16.5%) reached the study outcome. Factors F8 (prolonged PR-interval and P-wave duration, P < 0.005), F15 (reduced P-wave height, P = 0.04), F25 (increased right bundle branch delay, P = 0.02), F27 (P-wave axis P < 0.005), and F32 (reduced QRS-T voltages P = 0.03) were significantly associated with LTVA. CONCLUSION: Inherently explainable DNNs can detect patients at risk of LTVA which is mainly driven by P-wave abnormalities.


Asunto(s)
Cardiomiopatía Dilatada , Desfibriladores Implantables , Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Cardiomiopatía Dilatada/complicaciones , Cardiomiopatía Dilatada/diagnóstico , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Electrocardiografía/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Redes Neurales de la Computación , Factores de Riesgo , Volumen Sistólico , Función Ventricular Izquierda/fisiología
4.
Eur J Clin Invest ; 51(1): e13359, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32705678

RESUMEN

INTRODUCTION: The benefit of implantable cardioverter-defibrillator (ICD) implantation in patients with hemodynamically not tolerated ventricular tachycardia (VT) and midrange reduced to normal ejection fraction (LVEF >35%) is currently unclear. The purpose of this study was to investigate follow-up after hemodynamically not tolerated VT in patients with LVEF >35%. In addition, we aimed to find possible predictive factors to identify who will benefit from ICD implantation. METHODS: In a retrospective single-centre case series, all patients with hemodynamically not tolerated VT and LVEF >35% that underwent electrophysiological study (EPS) and/or radiofrequency VT ablation were included. RESULTS: Forty-two patients (5 women, median age 68 years) with hemodynamically not tolerated VT and LVEF >35% underwent EPS. VT ablation was performed in thirty-one patients, which was considered successful in twenty-three patients. Nineteen patients had an ICD at discharge while 23 patients were discharged without an ICD. The severity of hemodynamic compromise, LVEF and ablation success played an important role in the decision-making for ICD implantation. Six patients (14.3%) had recurrence of VT, all hemodynamically tolerated. CONCLUSIONS: In this small case series, patients with hemodynamically not tolerated VT and LVEF >35% had a relatively low recurrence rate and all recurrences were nonfatal. Based on our results, we hypothesize that the severity of hemodynamic compromise, LVEF and ablation success might modify the risk for VA recurrence. A prospective study to determine the prognostic value of these factors in patients with hemodynamically not tolerated VT and LVEF >35% is necessary.


Asunto(s)
Cardiomiopatías/fisiopatología , Enfermedad Coronaria/fisiopatología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Ablación por Radiofrecuencia , Volumen Sistólico/fisiología , Taquicardia Ventricular/cirugía , Anciano , Cardiomiopatías/complicaciones , Enfermedad Coronaria/complicaciones , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/fisiopatología , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos , Taquicardia Ventricular/complicaciones , Taquicardia Ventricular/fisiopatología , Resultado del Tratamiento
5.
Europace ; 23(23 Suppl 1): i80-i87, 2021 03 04.
Artículo en Inglés | MEDLINE | ID: mdl-33751077

RESUMEN

AIMS: Ventricular conduction disorders can induce arrhythmias and impair cardiac function. Bundle branch blocks (BBBs) are diagnosed by 12-lead electrocardiogram (ECG), but discrimination between BBBs and normal tracings can be challenging. CineECG computes the temporo-spatial trajectory of activation waveforms in a 3D heart model from 12-lead ECGs. Recently, in Brugada patients, CineECG has localized the terminal components of ventricular depolarization to right ventricle outflow tract (RVOT), coincident with arrhythmogenic substrate localization detected by epicardial electro-anatomical maps. This abnormality was not found in normal or right BBB (RBBB) patients. This study aimed at exploring whether CineECG can improve the discrimination between left BBB (LBBB)/RBBB, and incomplete RBBB (iRBBB). METHODS AND RESULTS: We utilized 500 12-lead ECGs from the online Physionet-XL-PTB-Diagnostic ECG Database with a certified ECG diagnosis. The mean temporo-spatial isochrone trajectory was calculated and projected into the anatomical 3D heart model. We established five CineECG classes: 'Normal', 'iRBBB', 'RBBB', 'LBBB', and 'Undetermined', to which each tracing was allocated. We determined the accuracy of CineECG classification with the gold standard diagnosis. A total of 391 ECGs were analysed (9 ECGs were excluded for noise) and 240/266 were correctly classified as 'normal', 14/17 as 'iRBBB', 55/55 as 'RBBB', 51/51 as 'LBBB', and 31 as 'undetermined'. The terminal mean temporal spatial isochrone contained most information about the BBB localization. CONCLUSION: CineECG provided the anatomical localization of different BBBs and accurately differentiated between normal, LBBB and RBBB, and iRBBB. CineECG may aid clinical diagnostic work-up, potentially contributing to the difficult discrimination between normal, iRBBB, and Brugada patients.


Asunto(s)
Bloqueo de Rama , Electrocardiografía , Potenciales de Acción , Arritmias Cardíacas/diagnóstico , Bloqueo de Rama/diagnóstico , Ventrículos Cardíacos , Humanos
6.
Europace ; 23(1): 139-146, 2021 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-33111141

RESUMEN

AIMS: Irreversible electroporation (IRE) ablation is a non-thermal ablation method based on the application of direct current between a multi-electrode catheter and skin electrode. The delivery of current through blood leads to electrolysis. Some studies suggest that gaseous (micro)emboli might be associated with myocardial damage and/or (a)symptomatic cerebral ischaemic events. The aim of this study was to compare the amount of gas generated during IRE ablation and during radiofrequency (RF) ablation. METHODS AND RESULTS: In six 60-75 kg pigs, an extracorporeal femoral shunt was outfitted with a bubble-counter to detect the size and total volume of gas bubbles. Anodal and cathodal 200 J IRE applications were delivered in the left atrium (LA) using a 14-electrode circular catheter. The 30 and 60 s 40 W RF point-by-point ablations were performed. Using transoesophageal echocardiography (TOE), gas formation was visualized. Average gas volumes were 0.6 ± 0.6 and 56.9 ± 19.1 µL (P < 0.01) for each anodal and cathodal IRE application, respectively. Also, qualitative TOE imaging showed significantly less LA bubble contrast with anodal than with cathodal applications. Radiofrequency ablations produced 1.7 ± 2.9 and 6.7 ± 7.4 µL of gas, for 30 and 60 s ablation time, respectively. CONCLUSION: Anodal IRE applications result in significantly less gas formation than both cathodal IRE applications and RF applications. This finding is supported by TOE observations.


Asunto(s)
Ablación por Catéter , Animales , Ablación por Catéter/efectos adversos , Catéteres , Electroporación , Gases , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Porcinos
7.
Europace ; 23(3): 464-468, 2021 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-33200191

RESUMEN

AIMS: We investigated the efficacy of linear multi-electrode irreversible electroporation (IRE) ablation in a porcine model. METHODS AND RESULTS: The study was performed in six pigs (weight 60-75 kg). After median sternotomy and opening of the pericardium, a pericardial cradle was formed and filled with blood. A linear seven polar 7-Fr electrode catheter with 2.5 mm electrodes and 2.5 mm inter-electrode spacing was placed in good contact with epicardial tissue. A single IRE application was delivered using 50 J at one site and 100 J at two other sites, in random sequence, using a standard monophasic defibrillator connected to all seven electrodes connected in parallel. The pericardium and thorax were closed and after 3 weeks survival animals were euthanized. A total of 82 histological sections from all 18 electroporation lesions were analysed. A total of seven 50 J and fourteen 100 J epicardial IRE applications were performed. Mean peak voltages at 50 and 100 J were 1079.2 V ± 81.1 and 1609.5 V ± 56.8, with a mean peak current of 15.4 A ± 2.3 and 20.2 A ± 1.7, respectively. Median depth of the 50 and 100 J lesions were 3.2 mm [interquartile range (IQR) 3.1-3.6] and 5.5 mm (IQR 4.6-6.6) (P < 0.001), respectively. Median lesion width of the 50 and 100 J lesions was 3.9 mm (IQR 3.7-4.8) and 5.4 mm (IQR 5.0-6.3), respectively (P < 0.001). Longitudinal sections showed continuous lesions for 100 J applications. CONCLUSION: Epicardial multi-electrode linear application of IRE pulses is effective in creating continuous deep lesions.


Asunto(s)
Ablación por Catéter , Electroporación , Animales , Catéteres , Electrodos , Pericardio/cirugía , Porcinos
8.
J Electrocardiol ; 69S: 67-74, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34325899

RESUMEN

BACKGROUND: The interpretation of the 12­lead ECG is notoriously difficult and requires experts to distinguish normal from abnormal ECG waveforms. ECG waveforms depend on body build and electrode positions, both often different in males and females. To relate the ECG waveforms to cardiac anatomical structures is even more difficult. The novel CineECG algorithm enables a direct projection of the 12­lead ECG to the cardiac anatomy by computing the mean location of cardiac activity over time. The aim of this study is to investigate the cardiac locations of the CineECG derived from standard 12­lead ECGs of normal subjects. METHODS: In this study we used 6525 12­lead ECG tracings labelled as normal obtained from the certified Physionet PTB XL Diagnostic ECG Database to construct the CineECG. All 12 lead ECGs were analyzed, and then divided by age groups (18-29,30-39,40-49,50-59,60-69,70-100 years) and by gender (male/female). For each ECG, we computed the CineECG within a generic 3D heart/torso model. Based on these CineECG's, the average normal cardiac location and direction for QRS, STpeak, and TpeakTend segments were determined. RESULTS: The CineECG direction for the QRS segment showed large variation towards the left free wall, whereas the STT segments were homogeneously directed towards the septal/apical region. The differences in the CineECG location for the QRS, STpeak, and TpeakTend between the age and gender groups were relatively small (maximally 10 mm at end T-wave), although between the gender groups minor differences were found in the 4 chamber direction angles (QRS 4°, STpeak 5°, and TpeakTend 8°) and LAO (QRS 1°, STpeak 13°, and TpeakTend 30°). CONCLUSION: CineECG demonstrated to be a feasible and pragmatic solution for ECG waveform interpretation, relating the ECG directly to the cardiac anatomy. The variations in depolarization and repolarization CineECG were small within this group of normal healthy controls, both in cardiac location as well as in direction. CineECG may enable an easier discrimination between normal and abnormal QRS and T-wave morphologies, reducing the amount of expert training. Further studies are needed to prove whether novel CineECG can significantly contribute to the discrimination of normal versus abnormal ECG tracings.


Asunto(s)
Electrocardiografía , Corazón , Adolescente , Algoritmos , Arritmias Cardíacas , Electrodos , Femenino , Humanos , Masculino
9.
J Electrocardiol ; 66: 69-76, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33794386

RESUMEN

INTRODUCTION: Longitudinal monitoring of sometimes subtle waveform changes of the 12­lead electrocardiogram (ECG) is complicated by patient-specific and technical factors, such as the inaccuracy of electrode repositioning. This feasibility study uses a 3D camera to reduce electrode repositioning errors, reduce ECG waveform variability and enable detailed longitudinal ECG monitoring. METHODS: Per subject, three clinical ECGs were obtained during routine clinical follow-up. Additionally, two ECGs were recorded guided by two 3D cameras, which were used to capture the precordial electrode locations and direct electrode repositioning. ECG waveforms and parameters were quantitatively compared between 3D camera guided ECGs and clinical ECGs. Euclidian distances between original and repositioned precordial electrodes from 3D guided ECGs were measured. RESULTS: Twenty subjects (mean age 65.1 ± 8.2 years, 35% females) were included. The ECG waveform variation between routine ECGs was significantly higher compared to 3D guided ECGs, for both the QRS complex (correlation coefficient = 0.90 vs 0.98, p < 0.001) and the STT segment (correlation coefficient = 0.88 vs. 0.96, p < 0.001). QTc interval variation was reduced for 3D camera guided ECGs compared to routine clinical ECGs (5.6 ms vs. 9.6 ms, p = 0.030). The median distance between 3D guided repositioned electrodes was 10.0 [6.4-15.2] mm, and did differ between males and females (p = 0.076). CONCLUSIONS: 3D guided repositioning of precordial electrodes resulted in, a low repositioning error, higher agreement between waveforms of consecutive ECGs and a reduction of QTc variation. These findings suggest that longitudinal monitoring of disease progression using 12­lead ECG waveforms is feasible in clinical practice.


Asunto(s)
Reposicionamiento de Medicamentos , Electrocardiografía , Anciano , Electrodos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad
10.
Europace ; 21(10): 1519-1526, 2019 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-31114860

RESUMEN

AIMS: Idiopathic ventricular fibrillation (IVF) is a rare cause of sudden cardiac arrest. Implantable cardioverter-defibrillator (ICD) implantation is currently the only treatment option. Limited data are available on the prevalence and complications of ICD therapy in these patients. We sought to investigate ICD therapy and its complications in patients with IVF. METHODS AND RESULTS: Patients were selected from a national registry of IVF patients. Patients in whom no underlying diagnosis was found during follow-up were eligible for inclusion. Recurrence of ventricular arrhythmia (VA) was derived from medical and ICD records, electrogram records of ICD therapies were used to differentiate between appropriate or inappropriate interventions. Independent predictors for appropriate ICD shock were calculated using cox regression. In 217 IVF patients, recurrence of sustained VAs occurred in 66 patients (30%) during a median follow-up period of 6.1 years. Ten patients died (4.6%). Thirty-eight patients (17.5%) experienced inappropriate ICD therapy, and 32 patients (14.7%) had device-related complications. Symptoms before cardiac arrest [hazard ratio (HR): 2.51, 95% confidence interval (CI): 1.48-4.24], signs of conduction disease (HR: 2.27, 95% CI: 1.15-4.47), and carrier of the DPP6 risk haplotype (HR: 3.24, 1.70-6.17) were identified as independent predictors of appropriate shock occurrence. CONCLUSION: Implantable cardioverter-defibrillator therapy is an effective treatment in IVF, treating recurrences of potentially lethal VAs in approximately one-third of patients during long-term follow-up. However, device-related complications and inappropriate shocks were also frequent. We found significant predictors for appropriate ICD therapy. This may imply that these patients require additional management to prevent recurrent events.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Electrocardiografía , Taquicardia Ventricular/terapia , Adulto , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Países Bajos/epidemiología , Taquicardia Ventricular/mortalidad , Taquicardia Ventricular/fisiopatología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA