Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Neurosurg ; : 1-7, 2022 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-35061986

RESUMEN

OBJECTIVE: The authors' objective was to examine the safety and efficacy of salvage intracranial cesium-131 brachytherapy in combination with resection of recurrent brain tumors. METHODS: The authors conducted a retrospective chart review of consecutive patients treated with intraoperative intracranial cesium-131 brachytherapy at a single institution. Permanent suture-stranded cesium-131 seeds were implanted in the resection cavity after maximal safe tumor resection. The primary outcomes of interest were local, locoregional (within 1 cm), and intracranial control, as well as rates of overall survival (OS), neurological death, symptomatic adverse radiation effects (AREs), and surgical complication rate graded according to Common Terminology Criteria for Adverse Events version 5.0. RESULTS: Between 2016 and 2020, 36 patients received 40 consecutive cesium-131 implants for 42 recurrent brain tumors and received imaging follow-up for a median (interquartile range [IQR]) of 17.0 (12.7-25.9) months. Twenty patients (55.6%) with 22 implants were treated for recurrent brain metastasis, 12 patients (33.3%) with 16 implants were treated for recurrent atypical (n = 7) or anaplastic (n = 5) meningioma, and 4 patients (11.1%) were treated for other recurrent primary brain neoplasms. All except 1 tumor (97.6%) had received prior radiotherapy, including 20 (47.6%) that underwent 2 or more prior radiotherapy treatments and 23 (54.8%) that underwent prior resection. The median (IQR) tumor size was 3.0 (2.3-3.7) cm, and 17 lesions (40.5%) had radiographic evidence of ARE prior to salvage therapy. Actuarial 1-year local/locoregional/intracranial control rates for the whole cohort and patients with metastases and meningiomas were 91.6%/83.4%/47.9%, 88.8%/84.4%/45.4%, and 100%/83.9%/46.4%, respectively. No cases of local recurrence of any histology (0 of 27) occurred after gross-total resection (p = 0.012, log-rank test). The 1-year OS rates for the whole cohort and patients with metastases and meningiomas were 82.7%, 79.1%, and 91.7%, respectively, and the median (IQR) survival of all patients was 26.7 (15.6-36.4) months. Seven patients (19.4%) experienced neurological death from progressive intracranial disease (7 of 14 total deaths [50%]), 5 (13.9%) of whom died of leptomeningeal disease. Symptomatic AREs were observed in 9.5% of resection cavities (n = 4), of which 1 (2.4%) was grade 3 in severity. The surgical complication rate was 16.7% (n = 7); 4 (9.5%) of these patients had grade 3 or higher complications, including 1 patient (2.4%) who died perioperatively. CONCLUSIONS: Cesium-131 brachytherapy resulted in good local control and acceptable rates of symptomatic AREs and surgical complications in this heavily pretreated cohort, and it may be a reasonable salvage adjuvant treatment for this patient population.

2.
Int J Radiat Oncol Biol Phys ; 67(2): 610-9, 2007 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-17236978

RESUMEN

PURPOSE: The aim of this study was to measure interfraction prostate bed motion, setup error, and total positioning error in 10 consecutive patients undergoing postprostatectomy radiotherapy. METHODS AND MATERIALS: Daily image-guided target localization and alignment using electronic portal imaging of gold seed fiducials implanted into the prostate bed under transrectal ultrasound guidance was used in 10 patients undergoing adjuvant or salvage radiotherapy after prostatectomy. Prostate bed motion, setup error, and total positioning error were measured by analysis of gold seed fiducial location on the daily electronic portal images compared with the digitally reconstructed radiographs from the treatment-planning CT. RESULTS: Mean (+/- standard deviation) prostate bed motion was 0.3 +/- 0.9 mm, 0.4 +/- 2.4 mm, and -1.1 +/- 2.1 mm in the left-right (LR), superior-inferior (SI), and anterior-posterior (AP) axes, respectively. Mean set-up error was 0.1 +/- 4.5 mm, 1.1 +/- 3.9 mm, and -0.2 +/- 5.1 mm in the LR, SI, and AP axes, respectively. Mean total positioning error was 0.2 +/- 4.5 mm, 1.2 +/- 5.1 mm, and -0.3 +/- 4.5 mm in the LR, SI, and AP axes, respectively. Total positioning errors >5 mm occurred in 14.1%, 38.7%, and 28.2% of all fractions in the LR, SI, and AP axes, respectively. There was no significant migration of the gold marker seeds. CONCLUSIONS: This study validates the use of daily image-guided target localization and alignment using electronic portal imaging of implanted gold seed fiducials as a valuable method to correct for interfraction target motion and to improve precision in the delivery of postprostatectomy radiotherapy.


Asunto(s)
Oro , Próstata/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico por imagen , Prótesis e Implantes , Planificación de la Radioterapia Asistida por Computador , Calibración , Humanos , Masculino , Movimiento , Próstata/cirugía , Prostatectomía , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/cirugía , Radiografía , Planificación de la Radioterapia Asistida por Computador/instrumentación , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Adyuvante , Terapia Recuperativa
3.
Technol Cancer Res Treat ; 16(3): 267-275, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-27037301

RESUMEN

This study compares conventional and robotic intensity modulated radiation therapy (IMRT) plans for prostate boost treatments and provides clinical insight into the strengths and weaknesses of each. The potential for dose escalation with robotic IMRT is further investigated using the "critical volume tolerance" method proposed by Roach et al. Three clinically acceptable treatment plans were generated for 10 prostate boost patients: (1) a robotic IMRT plan using fixed cones, (2) a robotic IMRT plan using the Iris variable aperture collimator, and (3) a conventional linac based IMRT (c-IMRT) plan. Target coverage, critical structure doses, homogeneity, conformity, dose fall-off, and treatment time, were compared across plans. The average bladder and rectum V75 was 17.1%, 20.0%, and 21.4%, and 8.5%, 11.9%, and 14.1% for the Iris, fixed, and c-IMRT plans, respectively. On average the conformity index (nCI) was 1.20, 1.30, and 1.46 for the Iris, fixed, and c-IMRT plans. Differences between the Iris and the c-IMRT plans were statistically significant for the bladder V75 (P= .016), rectum V75 (P= .0013), and average nCI (P =.002). Dose to normal tissue in terms of R50 was 4.30, 5.87, and 8.37 for the Iris, fixed and c-IMRT plans, respectively, with statistically significant differences between the Iris and c-IMRT (P = .0013) and the fixed and c-IMRT (P = .001) plans. In general, the robotic IMRT plans generated using the Iris were significantly better compared to c-IMRT plans, and showed average dose gains of up to 34% for a critical rectal volume of 5%.


Asunto(s)
Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Fraccionamiento de la Dosis de Radiación , Humanos , Masculino , Neoplasias de la Próstata/patología , Dosificación Radioterapéutica , Radioterapia Conformacional/métodos , Robótica/métodos
4.
J Radiosurg SBRT ; 3(1): 67-79, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-29296387

RESUMEN

PURPOSE/OBJECTIVE: Dose calculation in treatment planning must account for tissue heterogeneity, especially for tumors within low-density lung tissues. While Monte Carlo (MC) calculation methods are the most accurate, Ray Tracing (RT) methods are also commonly employed. We evaluated dose calculation differences between the RT and MC algorithms in central and peripheral lung tumors treated with CyberKnife SBRT to determine which planning parameters may predict dose differences. We also examined clinical outcomes of local-regional control (LRC) and long-term treatment-related toxicity as a function of calculation method. MATERIALS/METHODS: A retrospective series of 70 patient plans (19 central and 51 peripheral lung lesions) treated between 2009 and 2011 were analyzed. Among those, 33 were primary lung cancer and 37 were metastatic lesions. Thirty-three treatment plans were developed with the RT method, and 37 plans used MC. Groups were recalculated with the reciprocal method for dose comparison. Parameters examined to quantify dose differences between the two algorithms included: dose delivered to 95% (D95) of the planning target volume (PTV), dose heterogeneity, and dose to organs at risk (OAR). Dose differences were analyzed as a function of target volume, distance to soft tissue, and fraction of target overlap with soft tissue. For the subset of primary lung tumors, LRC was assessed radiographically at a median follow-up of 19 months (mo) (range, 2 to 41 mo). RESULTS: Compared to MC, the RT algorithm largely overestimated the dose delivered to the PTV. The dose difference between RT and MC plans correlated to the volume of PTV overlapping with soft tissue; the smaller the overlap volume, the larger the dose differences between RT and MC. Compared to MC, the RT algorithm overestimated the dose delivered to 10% of the ipsilateral lung (D10%). Evidence of local progression was noted in only one of the 31 patients treated for primary lung malignancy. DFS and OS were not significantly different between RT and MC plans. CONCLUSION: There is a significant range of discordance between MC and RT dose calculations for SBRT treated peripheral lung tumors. While variation is correlated to target size and proximity to soft tissue, no single parameter can reliably predict dose differences. Ultimately, local control and long-term toxicity appear independent of the dose calculation method.

5.
Med Dosim ; 33(1): 22-9, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18262119

RESUMEN

The purpose of this report was to evaluate the magnitude of the error that would be introduced if only a lateral (LAT) portal image, as opposed to a pair of orthogonal images, was used to verify and correct daily setup errors and organ motion in external beam radiation therapy (EBRT) of prostate cancer. The 3-dimensional (3D) coordinates of gold markers from 12 consecutive prostate patients were reconstructed using a pair of orthogonal images. The data were re-analyzed using only the LAT images. Couch moves from the 2-dimensional (2D)-only data were compared with the complete 3D data set. The 2D-only data provided couch moves that differed on average from the 3D data by 2.3 +/- 3.0, 0.0 +/- 0.0, and 0.8 +/- 1.0 mm in the Lat, AP, and SI directions, respectively. Along AP and SI axes, the LAT image provided positional information similar to the orthogonal pair. The error along the LAT axis may be acceptable provided lateral margins are large enough. A LAT-only setup protocol reduces patient treatment times and increases patient throughput. In most circumstances, with exceptions such as morbidly obese patients, acquisition of only a LAT image for daily targeting of the prostate will provide adequate positional precision.


Asunto(s)
Imagenología Tridimensional/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radioterapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Humanos , Masculino , Sistemas en Línea , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA