Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Radiographics ; 33(2): 341-59, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23479700

RESUMEN

Penetrating injuries account for a large percentage of visits to emergency departments and trauma centers worldwide. Emergency laparotomy is the accepted standard of care in patients with a penetrating torso injury who are not hemodynamically stable and have a clinical indication for exploratory laparotomy, such as evisceration or gastrointestinal bleeding. Continuous advances in technology have made computed tomography (CT) an indispensable tool in the evaluation of many patients who are hemodynamically stable, have no clinical indication for exploratory laparotomy, and are candidates for conservative treatment. Multidetector CT may depict the trajectory of a penetrating injury and help determine what type of intervention is necessary on the basis of findings such as active arterial extravasation and major vascular, hollow viscus, or diaphragmatic injuries. Because multidetector CT plays an increasing role in the evaluation of patients with penetrating wounds to the torso, the radiologists who interpret these studies should be familiar with the CT findings that mandate intervention.


Asunto(s)
Medios de Contraste , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/métodos , Torso/diagnóstico por imagen , Torso/lesiones , Heridas Penetrantes/diagnóstico por imagen , Humanos
2.
Neurosurgery ; 89(1): E35-E41, 2021 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-33734404

RESUMEN

BACKGROUND: While there are reports of acute ischemic stroke (AIS) in coronavirus disease 2019 (COVID-19) patients, the overall incidence of AIS and clinical characteristics of large vessel occlusion (LVO) remain unclear. OBJECTIVE: To attempt to establish incidence of AIS in COVID-19 patients in an international cohort. METHODS: A cross-sectional retrospective, multicenter study of consecutive patients admitted with AIS and COVID-19 was undertaken from March 1 to May 1, 2020 at 12 stroke centers from 4 countries. Out of those 12 centers, 9 centers admitted all types of strokes and data from those were used to calculate the incidence rate of AIS. Three centers exclusively transferred LVO stroke (LVOs) patients and were excluded only for the purposes of calculating the incidence of AIS. Detailed data were collected on consecutive LVOs in hospitalized patients who underwent mechanical thrombectomy (MT) across all 12 centers. RESULTS: Out of 6698 COVID-19 patients admitted to 9 stroke centers, the incidence of stroke was found to be 1.3% (interquartile range [IQR] 0.75%-1.7%). The median age of LVOs patients was 51 yr (IQR 50-75 yr), and in the US centers, African Americans comprised 28% of patients. Out of 66 LVOs, 10 patients (16%) were less than 50 yr of age. Among the LVOs eligible for MT, the average time from symptom onset to presentation was 558 min (IQR 82-695 min). A total of 21 (50%) patients were either discharged to home or discharged to acute rehabilitation facilities. CONCLUSION: LVO was predominant in patients with AIS and COVID-19 across 2 continents, occurring at a significantly younger age and affecting African Americans disproportionately in the USA.


Asunto(s)
Isquemia Encefálica/diagnóstico por imagen , Isquemia Encefálica/epidemiología , COVID-19/diagnóstico por imagen , COVID-19/epidemiología , Accidente Cerebrovascular Isquémico/diagnóstico por imagen , Accidente Cerebrovascular Isquémico/epidemiología , Adulto , Anciano , Anciano de 80 o más Años , Isquemia Encefálica/terapia , COVID-19/terapia , Trastornos Cerebrovasculares/diagnóstico por imagen , Trastornos Cerebrovasculares/epidemiología , Trastornos Cerebrovasculares/terapia , Estudios de Cohortes , Estudios Transversales , Femenino , Humanos , Incidencia , Internacionalidad , Accidente Cerebrovascular Isquémico/terapia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Trombectomía/efectos adversos , Resultado del Tratamiento
3.
Oper Neurosurg (Hagerstown) ; 14(4): 351-358, 2018 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-28521024

RESUMEN

BACKGROUND: Pericallosal artery aneurysm treatment may be challenging using traditional endovascular techniques. OBJECTIVE: To demonstrate the feasibility, efficacy, and safety of endovascular treatment of pericallosal artery aneurysm using flow diverters. METHODS: We performed a retrospective review of our institutional database from July 2013 through July 2016 and identified 7 subjects with a pericallosal artery aneurysm treated with the Pipeline embolization device (ev3 Neurovascular, Medtronic, Dublin, Ireland) and at least 1 follow-up angiogram. Technical feasibility, procedural complication, angiographic results, and clinical outcome were evaluated. RESULTS: Placement of the Pipeline embolization device was successful in all cases without evidence of procedural complication. Five out of 7 subjects showed a complete aneurysm occlusion at 6- to 12-mo follow-up angiogram. The 2 subjects with persistent aneurysm filling showed decreased aneurysm sac volume on follow-up angiograms (96% and 60%). There was no evidence of in-implant stenosis or intimal hyperplasia. No thromboembolic or hemorrhagic complications were seen during the follow-up period. Only 1 patient had a transient change in Modified Rankin scale score from baseline as a result of different unrelated procedure. CONCLUSION: Our preliminary results demonstrate feasibility of the use of flow diverter stent for treatment of aneurysms of the pericallosal artery with rate of aneurysm occlusion comparable to literature and without evidence of increased procedural or short-term morbidity. A long-term and larger cohort study is needed to validate our findings.


Asunto(s)
Embolización Terapéutica/instrumentación , Procedimientos Endovasculares/instrumentación , Aneurisma Intracraneal/terapia , Stents , Anciano , Angiografía Cerebral , Cuerpo Calloso/irrigación sanguínea , Diseño de Equipo , Femenino , Humanos , Imagenología Tridimensional , Aneurisma Intracraneal/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
4.
J Neurosci Methods ; 162(1-2): 244-54, 2007 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-17363066

RESUMEN

Many stroke research groups utilize the model of middle cerebral artery occlusion induced by insertion of an intraluminal thread, owing to its pragmatism and reliability of cerebral infarct generation. However, 75% of stroke cases result from a thromboembolic event and 10% from occlusive atherothrombosis in situ. Here, we characterize a mouse model of repeated thromboembolic stroke, which closely mimics the intravascular pathophysiology of arterial thrombus generation from an atherosclerotic plaque, and subsequent release of a thrombus into the cerebral circulation as an embolus. Common carotid artery thrombosis (CCAT) was induced photochemically leading to non-occlusive platelet aggregation in C57/BL6 male mice (n=35), and was followed by mechanical assistance to facilitate release of the thrombus (MRT) and thus promote embolism. Six experimental groups, differing by changes in the surgical protocol, were used for the purpose of determining which such procedure yielded the most reliable and consistent brain infarct volumes with the lowest mortality at 3 days after surgery. The group which best satisfied these conditions was a double insult group which consisted of animals that underwent CCAT for 2 min by means of argon laser irradiation (514.5 nm) at an intensity of ca. 130 W/cm(2), with concomitant injection of erythrosin B (EB) (35 mg/kg infused over those same 2 min), followed by MRT 1 min later; the entire procedure was repeated 24h later. This group showed a percent of brain lesion volume of 15+/-4% (mean+/-S.D.) with no associated 3-day mortality. Compared to a single insult group which sustained a percent brain lesion volume of 7+/-3%, there was a statistically significant (p<0.05) increase in the volume of infarction in the double-insult group.


Asunto(s)
Accidente Cerebrovascular/complicaciones , Tromboembolia/etiología , Animales , Velocidad del Flujo Sanguíneo , Modelos Animales de Enfermedad , Masculino , Ratones , Ratones Endogámicos C57BL , Arteria Cerebral Media/patología , Fotoquímica , Accidente Cerebrovascular/mortalidad , Tromboembolia/mortalidad , Ultrasonografía Doppler
5.
J Neurointerv Surg ; 9(6): 541-546, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27286991

RESUMEN

OBJECTIVE: To evaluate the safety and efficacy of the 'Baby Trevo' (Trevo XP ProVue 3×20 mm Retriever) stent retriever for large vessel occlusions (LVOs) in acute ischemic stroke (AIS). MATERIALS AND METHODS: We retrospectively analyzed our stroke database and included all patients treated with the Baby Trevo for distal LVOs in AIS. Patient gender, mean age, vascular risk factors, National Institutes of Health Stroke Scale (NIHSS) score at presentation, and modified Rankin Scale (mRS) score at baseline and 90-day follow-up were documented. Reperfusion rates for the vessels treated were recorded using the Thrombolysis in Cerebral Infarction (TICI) classification. Occurrence of vasospasm and new or evolving infarcts in the treated vascular territory was documented. RESULTS: Thirty-five subjects with a mean NIHSS score of 18 were included. The Baby Trevo device was used in 38 branches of the anterior and posterior circulations. TICI 2b/3 blood flow was restored after one single pass in 20/38 (52.6%) and after two or three passes in 11 vessels. The remaining vessels required either more than three passes, showed less than a TICI 2b/3 reperfusion (n=3), or demonstrated failure to retrieve the clot (n=4). TICI 2b/3 reperfusion was achieved in 30 patients (85.7%). No vessel injuries, rupture, or significant vasospasm were seen. Overall, a mRS score of ≤2 was seen in 56.5% of the subjects successfully treated with the Baby Trevo at 90 days and in 81.3% of surviving patients; seven patients died (20%). CONCLUSIONS: Our preliminary data suggest that the 'Baby Trevo' achieves a high recanalization rate without any significant risk. Larger cohort studies are needed to validate the clinical benefit.


Asunto(s)
Isquemia Encefálica/diagnóstico por imagen , Isquemia Encefálica/cirugía , Stents/efectos adversos , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/cirugía , Trombectomía/métodos , Adulto , Anciano , Anciano de 80 o más Años , Circulación Cerebrovascular , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Reperfusión/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Trombectomía/instrumentación , Factores de Tiempo , Resultado del Tratamiento
6.
Interv Neuroradiol ; 23(2): 129-136, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27956518

RESUMEN

Background Flow diverter (FD) malapposition is associated with stroke-related complications. We document the use of self-expanding nitinol stents to remove/reduce the ledge of a FD deployed for aneurysm treatment. Methods We identified five patients who were treated with the Pipeline embolization device (PED) in conjunction with a Neuroform EZ stent for inadequate wall apposition of the ends of the FD at our institution between May 2014 and July 2015. Among other parameters, angiographic results, cone-beam computed tomography assessment of wall apposition and patient clinical outcome were evaluated. Results Incomplete device end apposition was seen in three cases, and precarious positioning of the distal end of the PED over the aneurysm neck was seen in two cases. In all five cases, successful treatment with good wall apposition and proper pinning of the PED distal edge was achieved using an additional Neuroform EZ stent. Appropriate aneurysm neck coverage and flow stagnation was seen in all cases. The combination of high radial outward force and open-cell design permits the Neuroform EZ stent to jail the malappositioned edges of the FD while maintaining good vessel-wall apposition itself and prevent migration of the PED. Short-term follow-up angiography showed device patency and complete aneurysm obliteration in all cases. Conclusions Preliminary results of this small case series suggest that the Neuroform EZ stent allows for effective treatment of FD malapposition in selected patients amenable for this endovascular approach. Long-term and larger cohort studies are needed to validate these results.


Asunto(s)
Prótesis Vascular , Embolización Terapéutica/instrumentación , Aneurisma Intracraneal/terapia , Stents , Adulto , Anciano , Aleaciones , Angiografía de Substracción Digital , Angiografía Cerebral , Tomografía Computarizada de Haz Cónico , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
7.
J Neurointerv Surg ; 9(12): 1208-1213, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27888225

RESUMEN

OBJECTIVE: Evaluation of the safety and efficacy of the Pipeline embolization device (PED) when used as second-line treatment for recurrent or residual, pretreated ruptured and unruptured intracranial aneurysms (IAs). METHODS: Retrospective review of our database to include all patients who were treated with a PED for recurrent or residual IAs following surgical clipping or coiling. We evaluated neurological outcome and angiograms at discharge, 6- and 12-months' follow-up and assessed intimal hyperplasia at follow-up. RESULTS: Twenty-four patients met our inclusion criteria. Most IAs were located in the anterior circulation (n=21). No change of preprocedure modified Rankin Scale score was seen at discharge or at any scheduled follow-up. Complete or near-complete aneurysm occlusion on 6- and 12-month angiograms was seen in 94.4% (17/18 cases) and 93.3% (14/15 cases), respectively. Complete or near-complete occlusion was seen in 100% of previously ruptured and 85.7% (6/7 cases) and 83.3% (5/6 cases) of previously unruptured cases at the 6- and 12-months' follow-up, respectively. One case of moderate intimal hyperplasia was observed at 6 months and decreased to mild at the 12-months' follow-up. No difference in device performance was observed among pretreated unruptured or ruptured IAs. CONCLUSIONS: Treatment of recurrent or residual IAs with a PED after previous coiling or clipping is feasible and safe. There is no difference in device performance between ruptured or unruptured IAs.


Asunto(s)
Aneurisma Roto/diagnóstico por imagen , Aneurisma Roto/terapia , Embolización Terapéutica/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Adulto , Anciano , Angiografía/métodos , Embolización Terapéutica/instrumentación , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
8.
J Neurointerv Surg ; 8(10): 1048-51, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26546600

RESUMEN

BACKGROUND: Dissecting aneurysms of the vertebral artery (VA) are difficult to treat using current surgical and endovascular techniques. OBJECTIVE: To analyze retrospectively the efficacy and safety of flow diverters in the treatment of dissecting aneurysms of the vertebral artery. METHODS: We identified six patients with six unruptured VA dissecting aneurysms either arising from the V4 or V3-V4 junction that were treated with the Pipeline embolization device (PED) at our institution between July 2012 and February 2015. Among other parameters, technical feasibility of the procedure, procedure-related complications, angiographic results, and clinical outcome were evaluated. RESULTS: PED placement was achieved in all cases and immediate angiography follow-up demonstrated intra-aneurysmal contrast stasis with parent artery preservation. A temporary episode of dysarthria was noted in one patient. Major procedure-related complications were not observed. The 6-month follow-up (n=6) demonstrated complete/near-complete aneurysm obliteration in five patients and partial obliteration in one. At the 1-year follow-up (n=5) stable complete aneurysm occlusion was seen in two patients. Two cases showed progression from near complete occlusion and partial occlusion at 6 months to complete occlusion and near complete occlusion. One cases showed unchanged near complete occlusion. No aneurysmal bleeding, in-stent stenosis or thromboembolic complication was seen. National Institutes of Health Stroke Scale and modified Rankin scale scores remained unchanged from admission to discharge. CONCLUSIONS: Our preliminary experience with the use of PED for the treatment of intradural VA dissecting aneurysms shows promising short-term results, making this technique a feasible and safe treatment option in patients suitable for this approach. However, long-term and larger cohort studies are needed to validate these results.


Asunto(s)
Embolización Terapéutica/métodos , Procedimientos Endovasculares/métodos , Aneurisma Intracraneal/cirugía , Stents , Disección de la Arteria Vertebral/cirugía , Adulto , Angiografía de Substracción Digital , Angiografía Cerebral , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/uso terapéutico , Complicaciones Posoperatorias/epidemiología , Estudios Retrospectivos , Resultado del Tratamiento
9.
Cureus ; 8(5): e617, 2016 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-27382525

RESUMEN

The endovascular management of acute ischemic stroke (AIS) due to emergency large vessel occlusion (ELVO) has become the standard of care after the recent publication of landmark randomized, controlled trials. Mechanical thrombectomy, in addition to intravenous thrombolysis (within 4.5 hours when eligible), is now part of the algorithm of the standard of care when treating AIS in patients with ELVO in the anterior circulation up to six hours after symptom onset. A newly introduced device, the Arc™ intracranial support catheter (Medtronic, Irvine, USA), is specifically designed for the introduction of neurointerventional devices into the cerebral vasculature and facilitates the delivery of microcatheters into smaller, more distal intracranial vessels. This technical report describes the use of the Arc™ intracranial support catheter in the setting of AIS.

10.
J Cereb Blood Flow Metab ; 29(3): 534-44, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19066616

RESUMEN

Inflammation is a major contributor to the pathogenesis of cerebral ischemia and stroke. In the peripheral immune response, caspase-1 activation involves the formation of a macromolecular complex termed the inflammasome. We determined whether nucleotide-binding, leucine-rich repeat, pyrin domain containing 1 (NLRP1), molecular platform consisting of capase-1, apoptosis-associated speck-like protein containing a caspase-activating recruitment domain (ASC), and NLRP1, is expressed in the normal and postischemic brain. Mice underwent thromboembolic stroke to investigate the formation of the inflammasome and subsequent activation of downstream inflammatory responses. Western blot analysis showed expression and activation of interleukin (IL) IL-1beta and IL-18 at 24 h after stroke. Size-exclusion chromatography and coimmunoprecipitation analysis showed protein association between NLRP1, ASC, caspase-1, and the X-linked inhibitor of apoptosis protein (XIAP). After ischemia, immunohistochemical analysis revealed inflammasome proteins in neurons, astrocytes, and microglia/macrophages. The potential of the inflammasome as an antiinflammatory target was showed by interference of inflammasome activation resulting in reduced cytokine levels in mice treated after ischemia with a neutralizing antibody against NLRP1. These findings show that the inflammasome complex forms after focal brain ischemia and may be a novel therapeutic target for reducing the detrimental consequences of postischemic inflammation.


Asunto(s)
Proteínas Adaptadoras Transductoras de Señales/antagonistas & inhibidores , Proteínas Reguladoras de la Apoptosis/antagonistas & inhibidores , Trombosis de las Arterias Carótidas/complicaciones , Encefalitis/prevención & control , Accidente Cerebrovascular/etiología , Tromboembolia/complicaciones , Proteínas Adaptadoras Transductoras de Señales/inmunología , Animales , Anticuerpos Monoclonales/farmacología , Anticuerpos Monoclonales/uso terapéutico , Proteínas Reguladoras de la Apoptosis/inmunología , Trombosis de las Arterias Carótidas/inmunología , Caspasa 1/inmunología , Inhibidores de Caspasas , Encefalitis/inmunología , Inmunoprecipitación , Interleucina-18/antagonistas & inhibidores , Interleucina-18/inmunología , Interleucina-1beta/antagonistas & inhibidores , Interleucina-1beta/inmunología , Masculino , Ratones , Ratones Endogámicos , Accidente Cerebrovascular/inmunología , Tromboembolia/inmunología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA