Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Eur J Orthod ; 46(1)2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38086543

RESUMEN

OBJECTIVES: Orthodontic retainers should restrict physiological tooth mobility as little as possible. While this has been investigated for multistranded retainers, there is a lack of data for novel CAD/CAM retainers. To address this, the present study compared the restriction of physiological tooth mobility in multistranded retainers and different CAD/CAM retainers. MATERIAL/METHODS: One group of multistranded (n = 8) and five groups of CAD/CAM retainers (nickel-titanium (NiTi), titanium grade 5 (Ti5), polyetheretherketone (PEEK), zirconia (ZrO2), and cobalt-chromium (CoCr); each n = 8) bonded from canine to canine were investigated for their influence on vertical and horizontal tooth mobility using an in vitro model of a lower arch in a universal testing machine. Load-deflection curves were determined and statistically analysed. RESULTS: All retainers restricted tooth mobility to varying extents. The retainers had less of an influence on vertical tooth mobility, with less of a difference between retainers (14%-38% restriction). In contrast, significant (P ≤ 0.05) differences were observed between retainers in the restriction of horizontal tooth mobility. ZrO2 retainers had the greatest impact, restricting horizontal tooth mobility by 82% (68 ± 20 µm/100N), followed by CoCr (75%, 94 ± 26 µm/100N) and PEEK (73%, 103 ± 28 µm/100N) CAD/CAM retainers, which had comparable effects on horizontal tooth mobility. Ti5 (54%, 175 ± 66 µm/100N) and NiTi (34%, 248 ± 119 µm/100N) CAD/CAM retainers had less of an influence on horizontal tooth mobility, and were comparable to multistranded retainers (44%, 211 ± 77 µm/100N). LIMITATIONS: This is an in vitro study, so clinical studies are needed to draw clinical conclusions. CONCLUSIONS: Multistranded and CAD/CAM retainers have different effects on tooth mobility in vitro. These effects should be further explored in future in vivo studies.


Asunto(s)
Aleaciones , Benzofenonas , Níquel , Polímeros , Titanio , Movilidad Dentaria , Humanos , Circonio , Diseño Asistido por Computadora
2.
Clin Oral Investig ; 27(9): 5131-5140, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37410153

RESUMEN

OBJECTIVES: To validate a new tooth mobility simulating in vitro model for biomechanical tests of dental appliances and restorations. MATERIAL AND METHODS: Load-deflection curves for teeth in CAD/CAM models (n = 10/group, 6 teeth/model) of the anterior segment of a lower jaw with either low tooth mobility (LM) or high tooth mobility (HM) were recorded with a universal testing device and a Periotest device. All teeth were tested before and after different ageing protocols. Finally, vertical load capacity (Fmax) was tested in all teeth. RESULTS: At F = 100 N load, vertical/horizontal tooth deflections before ageing were 80 ± 10 µm/400 ± 40 µm for LM models and 130 ± 20 µm/610 ± 100 µm for HM models. Periotest values were 1.6 ± 1.4 for LM models and 5.5 ± 1.5 for HM models. These values were within the range of physiological tooth mobility. No visible damage occurred during ageing and simulated ageing had no significant effect on tooth mobility. Fmax values were 494 ± 67 N (LM) and 388 ± 95 N (HM). CONCLUSION: The model is practical, easy to manufacture and can reliably simulate tooth mobility. The model was also validated for long-term testing, so is suitable for investigating various dental appliances and restorations such as retainers, brackets, dental bridges or trauma splints. CLINICAL RELEVANCE: Using this in-vitro model for high standardised investigations of various dental appliances and restorations can protect patients from unnecessary burdens in trials and practice.


Asunto(s)
Movilidad Dentaria , Humanos , Diseño Asistido por Computadora , Modelos Dentales
3.
Clin Oral Investig ; 27(5): 2375-2384, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36640179

RESUMEN

OBJECTIVES: To evaluate the diagnostic MRI compatibility of different fixed orthodontic retainers using a high-resolution 3D-sequence optimized for artifact reduction. MATERIALS AND METHODS: Maxillary and mandibular retainers made of five different materials were scanned in vitro and in vivo at 3 T MRI using an MSVAT-SPACE sequence. In vitro, artifact volumes were determined for all maxillary and mandibular retainers (AVmax; AVmand). In vivo, two independent observers quantified the extent of artifacts based on the visibility of 124 dental and non-dental landmarks using a five-point rating scale (1 = excellent, 2 = good, 3 = acceptable, 4 = poor, 5 = not visible). RESULTS: Rectangular-steel retainers caused the largest artifacts (AVmax/AVmand: 18,060/15,879 mm3) and considerable diagnostic impairment in vivo (mean landmark visibility score ± SD inside/outside the retainer areas: 4.8 ± 0.8/2.9 ± 1.6). Smaller, but diagnostically relevant artifacts were observed for twistflex steel retainers (437/6317 mm3, 3.1 ± 1.7/1.3 ± 0.7). All retainers made of precious-alloy materials produced only very small artifact volumes (titanium grade 1: 70/46 mm3, titanium grade 5: 47/35 mm3, gold: 23/21 mm3) without any impact on image quality in vivo (each retainer: visibility scores of 1.0 ± 0.0 for all landmarks inside and outside the retainer areas). CONCLUSIONS: In contrast to steel retainers, titanium and gold retainers are fully compatible for both head/neck and dental MRI when using MSVAT-SPACE. CLINICAL RELEVANCE: This study demonstrates that titanium and gold retainers do not impair the diagnostic quality of head/neck and dental MRI when applying an appropriate artifact-reduction technique. Steel retainers, however, are not suitable for dental MRI and can severely impair image quality in head/neck MRI of the oral cavity.


Asunto(s)
Retenedores Ortodóncicos , Titanio , Boca , Imagen por Resonancia Magnética/métodos , Acero Inoxidable , Oro
4.
Clin Oral Investig ; 26(5): 4173-4182, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35103838

RESUMEN

OBJECTIVES: Accurate description of buccal bone adjacent to mandibular anterior teeth is helpful for planning and monitoring periodontal and orthodontic treatment. Low-dose cone beam computed tomography (LD-CBCT) imaging has shown promising results for very small dental structures in animals. This study asserts that LD-CBCT is sufficiently accurate to measure buccal alveolar bone adjacent to human mandibular anterior teeth. MATERIALS AND METHODS: Buccal bone level adjacent to 16 mandibular anterior teeth from four human cadavers was measured radiographically using one high-dose (HD) CBCT protocol and two LD-CBCT protocols. The resulting radiographic measurements of buccal bone height (bl) and thickness (bt) were compared with reference probe and reflected-light microscopy measurements. Measurement medians and Bland-Altman plots were calculated, and a linear mixed model was used to compare raters and imaging modalities. RESULTS: All regression coefficients were approximately 0, indicating high interrater, intrarater, and intermodality agreement. No significant differences were found between reference measurements and CBCT protocols. The mean differences for bl measurements were 0.07 mm (rater 1 [r1]) and 0.12 mm (rater 2 [r2]) for HD-CBCT; 0.07 mm (r1) and 0.13 mm (r2) for LD-CBCT-1; and 0.02 mm (r1) and 0.01 mm (r2) for LD-CBCT-2. For bt measurements, mean differences were 0.02 mm (r1) and 0.02 mm (r2) for HD-CBCT; 0.01 mm (r1) and 0.01 mm (r2) for LD-CBCT-1; and 0.00 mm (r1) and 0.01 mm (r2) for LD-CBCT-2. CONCLUSIONS: Within the limitations of the present study, LD-CBCT seems to be a precise method for describing buccal bone and its thickness adjacent to mandibular anterior teeth in this experimental setting. CLINICAL RELEVANCE: For the first time, this study showed LD-CBCT produces excellent results and is a reliable modality for imaging buccal bone in vitro. If clinical studies confirm these results, LD-CBCT could enable better treatment planning and monitoring at a radiation dose that is far lower than that of conventional HD-CBCT but similar to that of panoramic views.


Asunto(s)
Tomografía Computarizada de Haz Cónico Espiral , Animales , Tomografía Computarizada de Haz Cónico/métodos , Incisivo , Planificación de Atención al Paciente , Proyectos Piloto
5.
Clin Oral Investig ; 26(12): 7149-7155, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35982349

RESUMEN

OBJECTIVES: To investigate whether artificial CAD/CAM processed (computer-aided design/manufacturing) teeth could be a feasible option for the production of dental in vitro models for biomechanical testing. MATERIAL AND METHODS: Disks (n = 10 per group) made from two different CAD/CAM-materials, one fiber-reinforced composite (FRC; Trinia, Bicon) and one polymethylmethacrylate-based resin (PMMA; Telio CAD, Ivoclar Vivadent), as well as bovine teeth (n = 10), were tested for their shear bond strength (SBS) and scored according to the adhesive remnant index (ARI). In addition, CAD/CAM-manufactured lower incisor teeth were tested for their ultimate load (Fu). RESULTS: With regard to SBS, both PMMA (17.4 ± 2.2 MPa) and FRC (18.0 ± 2.4 MPa) disks showed no significant difference (p = 0.968) compared to bovine disks (18.0 ± 5.4 MPa). However, the samples differed with regard to their failure mode (PMMA: ARI 4, delamination failure; FRC: ARI 0 and bovine: ARI 1.6, both adhesive failure). With regard to Fu, FRC-based teeth could withstand significantly higher loads (708 ± 126 N) than PMMA-based teeth (345 ± 109 N) (p < 0.01). CONCLUSION: Unlike PMMA-based teeth, teeth made from FRC showed sufficiently high fracture resistance and comparable SBS. Thus, FRC teeth could be a promising alternative for the production of dental in vitro models for orthodontic testing. CLINICAL RELEVANCE: CAD/CAM-processed teeth made from FRC enable the use of standardized geometry and constant material properties. Using FRC teeth in dental in vitro studies has therefore the potential to identify differences between various treatment options with rather small sample sizes, while remaining close to the clinical situation.


Asunto(s)
Recubrimiento Dental Adhesivo , Diente Artificial , Bovinos , Animales , Polimetil Metacrilato/química , Ensayo de Materiales , Resinas Compuestas/química , Diseño Asistido por Computadora , Resistencia al Corte , Propiedades de Superficie , Análisis del Estrés Dental
6.
Clin Oral Investig ; 25(3): 1547-1558, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32789656

RESUMEN

OBJECTIVES: The aim of this single-center randomized controlled trial (NCT03753256) was to assess orthodontic surface sealant layer thickness and integrity in vivo during a 12-month follow-up by optical coherence tomography (OCT). MATERIALS AND METHODS: Using a split-mouth design, quadrants of 20 patients treated with fixed orthodontic appliances were included. Quadrants were randomly assigned to the sealants Pro Seal® (PS) or Opal® Seal™ (OS). OCT scans were performed immediately after the application of the sealants and after 3, 6, 9, and 12 months. Sealant layer thicknesses and their integrity were determined at 5 regions of interest (ROIs) known for high risks of demineralization. Sealant integrity loss was determined using a self-developed scale. RESULTS: A total of 16 patients successfully completed the study. The studied sealants showed significant differences in initial layer thickness. Mean layer thickness was significantly lower for PS (67.8 µm, (95% CI, 56.1-79.5)) than for OS (110.7 µm, (95% CI, 97.3-124.1)). Layer thickness loss was significant after 3 months for PS and after 6 months for OS. Sealant integrity was compromised in more than 50% of the ROIs already after 3 months for both sealants. CONCLUSIONS: Patients treated with fixed orthodontic surface sealants lost the integrity of the protective layer in more than 50% of cases after 3 months, and the layer thickness of the sealants was significantly reduced after 3-6 months. CLINICAL RELEVANCE: The protective effect against demineralization lesions of orthodontic sealants in patients treated with fixed appliances appears to be limited in time. Further preventive measures should be investigated. TRIAL REGISTRATION: ClinicalTrials.gov (NCT03753256).


Asunto(s)
Selladores de Fosas y Fisuras , Tomografía de Coherencia Óptica , Estudios de Seguimiento , Humanos , Selladores de Fosas y Fisuras/uso terapéutico
7.
Clin Oral Investig ; 25(3): 1423-1431, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32785849

RESUMEN

OBJECTIVES: Magnetic resonance imaging (MRI) image quality can be severely impaired by artifacts caused by fixed orthodontic retainers. In clinical practice, there is a trend towards using computer-aided design/computer-aided manufacturing (CAD/CAM) retainers. This study aimed to quantify MRI artifacts produced by these novel CAD/CAM retainers. MATERIAL AND METHODS: Three CAD/CAM retainers and a stainless-steel retainer ("Twistflex"; clinical reference standard) were scanned in vitro at 3-T MRI using a high-resolution 3D sequence. The artifact diameters and three-dimensional artifact volumes (AV) were determined for all mandibular (AVmand) and maxillary (AVmax) retainers. Moreover, the corresponding ratio of artifact volume to retainer volume (AV/RVmand, AV/RVmax) was calculated. RESULTS: Twistflex caused large artifact volumes (AVmand: 13530 mm3; AVmax: 15642 mm3; AV/RVmand: 2602; AV/RVmax: 2235). By contrast, artifact volumes for CAD/CAM retainers were substantially smaller: whereas artifact volumes for cobalt-chromium retainers were moderate (381 mm3; 394 mm3; 39; 31), grade-5 titanium (110 mm3; 126 mm3; 12; 12) and nickel-titanium (54 mm3; 78 mm3; 12; 14) both produced very small artifact volumes. CONCLUSION: All CAD/CAM retainers caused substantially smaller volumes of MRI artifacts compared to Twistflex. Grade-5 titanium and nickel-titanium CAD/CAM retainers showed the smallest artifact volumes. CLINICAL RELEVANCE: CAD/CAM retainers made from titanium or nickel-titanium may not relevantly impair image quality in head/neck and dental MRI. Artifacts caused by cobalt-chromium CAD/CAM retainers may mask nearby dental/periodontal structures. In contrast, the large artifacts caused by Twistflex are likely to severely impair diagnosis of oral and adjacent pathologies.


Asunto(s)
Artefactos , Retenedores Ortodóncicos , Diseño Asistido por Computadora , Imagen por Resonancia Magnética , Acero Inoxidable , Titanio
8.
J Oral Rehabil ; 48(1): 18-27, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32997826

RESUMEN

BACKGROUND AND OBJECTIVE: Objective of this study was to determine whether the diagnostic accuracy of the Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) is sufficient for use among schoolchildren aged 8-12 years. METHODS: This prospective cohort study on diagnostic accuracy with calibrated examiners was conducted among 533 children of both sexes aged 8-12 years, with and without TMD symptoms, selected randomly from the Rhein-Neckar district. Self-reporting of non-dental facial pain was used as the reference standard, against which we calculated the following for the pain-related items of the DC/TMD (index test): sensitivity, specificity, positive and negative likelihood ratios, diagnostic odds ratio, accuracy and 95% Wilson Score confidence intervals. We also calculated the area under the receiver-operating characteristic (AUROC) curve displaying sensitivity and specificity. RESULTS: Our final sample consisted of 282 children, half of whom reported having facial pain and 3.2% reported sounds from the temporomandibular joints (TMJs). Despite high specificity (90.78%; 95% confidence interval (CI): [84.86%; 94.53%]), sensitivity of the adapted DC/TMD for pain on maximum jaw opening was poor (37.59%; 95% CI: [30.02%; 45.81%]). For pain on palpation, more similar values were recorded for sensitivity (74.47%; 95% CI: [66.69%; 80.95%]) and specificity (70.21%; 95% CI: [62.21%; 77.14%]). The diagnostic odds ratio was >1 for both examinations. The AUROC for pain on opening was 68.39% (95% CI: [62.62%; 74.16%]), and for pain on palpation, it was 74.63% (95% CI: [69.45%; 79.81%]), whereas the combination of both resulted to an AUROC of 74.09% (95% CI: [68.96%; 79.21%]). It was not possible to measure the diagnostic accuracy of the DC/TMD regarding TMJ sounds or jaw-opening limitations, as they occurred too rarely in our sample. CONCLUSION: In this study, the diagnostic accuracy of the DC/TMD for TMD-related pain in children was lower than that recorded for adults in previous studies.


Asunto(s)
Trastornos de la Articulación Temporomandibular , Adulto , Anciano , Niño , Dolor Facial/diagnóstico , Femenino , Humanos , Masculino , Estudios Prospectivos , Sensibilidad y Especificidad , Articulación Temporomandibular , Trastornos de la Articulación Temporomandibular/diagnóstico
9.
Int J Mol Sci ; 22(15)2021 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-34361063

RESUMEN

BACKGROUND: Induced tooth movement during orthodontic therapy requires mechano-induced bone remodeling. Besides various cytokines and growth-factors, neuronal guidance molecules gained attention for their roles in bone homeostasis and thus, potential roles during tooth movement. Several neuronal guidance molecules have been implicated in the regulation of bone remodeling. Amongst them, Semaphorin 3A is particular interesting as it concurrently induces osteoblast differentiation and disturbs osteoclast differentiation. METHODS: Mechano-regulation of Sema3A and its receptors PlexinA1 and Neuropilin (RT-qPCR, WB) was evaluated by applying compressive and tension forces to primary human periodontal fibroblasts (hPDLF) and alveolar bone osteoblasts (hOB). The association of the transcription factor Osterix (SP7) and SEMA3A was studied by RT-qPCR. Mechanisms involved in SEMA3A-mediated osteoblast differentiation were assessed by Rac1GTPase pull-downs, ß-catenin expression analyses (RT-qPCR) and nuclear translocation assays (IF). Osteogenic markers were analyzed by RT-qPCR. RESULTS: SEMA3A, PLXNA1 and NRP1 were differentially regulated by tension or compressive forces in hPDLF. Osterix (SP7) displayed the same pattern of regulation. Recombinant Sema3A induced the activation of Rac1GTPase, the nuclear translocation of ß-catenin and the expression of osteogenic marker genes. CONCLUSION: Sema3A, its receptors and Osterix are regulated by mechanical forces in hPDLF. SEMA3A upregulation was associated with Osterix (SP7) modulation. Sema3A-enhanced osteogenic marker gene expression in hOB might be dependent on a pathway involving Rac1GTPase and ß-catenin. Thus, Semaphorin 3A might contribute to bone remodeling during induced tooth movement.


Asunto(s)
Fibroblastos/fisiología , Proteínas del Tejido Nervioso/metabolismo , Neuropilinas/metabolismo , Osteoblastos/fisiología , Ligamento Periodontal/fisiología , Receptores de Superficie Celular/metabolismo , Semaforina-3A/metabolismo , Técnicas de Movimiento Dental/métodos , Adolescente , Adulto , Remodelación Ósea , Diferenciación Celular , Células Cultivadas , Niño , Fibroblastos/citología , Humanos , Proteínas del Tejido Nervioso/genética , Neuropilinas/genética , Osteoblastos/citología , Osteogénesis , Ligamento Periodontal/citología , Receptores de Superficie Celular/genética , Semaforina-3A/genética , Adulto Joven
10.
Eur Radiol ; 30(3): 1488-1497, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31802215

RESUMEN

OBJECTIVES: To evaluate whether magnetic resonance imaging (MRI) can serve as an alternative diagnostic tool to the "gold standard" cone-beam computed tomography (CBCT) in 3D cephalometric analysis. METHODS: In this prospective feasibility study, 12 patients (8 males, 4 females; mean age ± SD, 26.1 years ± 6.6) underwent 3D MRI and CBCT before orthognathic surgery. 3D cephalometric analysis was performed twice by two independent observers on both modalities. For each dataset, 27 cephalometric landmarks were defined from which 35 measurements (17 angles, 18 distances) were calculated. Statistical analyses included the calculation of Euclidean distances, intraclass correlation coefficients (ICCs), Bland-Altman analysis, and equivalence testing (linear mixed effects model) with a predefined equivalence margin of ± 1°/1 mm. RESULTS: Analysis of reliability for CBCT vs. MRI (intra-rater I/intra-rater II/inter-rater) revealed Euclidean distances of 0.86/0.86/0.98 mm vs. 0.93/0.99/1.10 mm for landmarks, ICCs of 0.990/0.980/0.986 vs. 0.982/0.978/0.980 for angles, and ICCs of 0.992/0.988/0.989 vs. 0.991/0.985/0.988 for distances. Bland-Altman analysis showed high levels of agreement between CBCT and MRI with bias values (95% levels of agreement) of 0.03° (- 1.49; 1.54) for angles and 0.02 mm (- 1.44; 1.47) for distances. In the linear mixed effects model, the mean values of CBCT and MRI measurements were equivalent. CONCLUSION: This feasibility study indicates that MRI enables reliable 3D cephalometric analysis with excellent agreement to corresponding measurements on CBCT. Thus, MRI could serve as a non-ionizing alternative to CBCT for treatment planning and monitoring in orthodontics as well as oral and maxillofacial surgery. KEY POINTS: • Clinically established 3D cephalometric measurements performed on MRI are highly reliable and show an excellent agreement with CBCT (gold standard). • The MRI technique applied in this study could be used as a non-ionizing diagnostic tool in orthodontics as well as oral and maxillofacial surgery. • Since most patients benefiting from 3D cephalometry are young in age, the use of MRI could substantially contribute to radiation protection and open up new possibilities for treatment monitoring.


Asunto(s)
Algoritmos , Cefalometría/métodos , Tomografía Computarizada de Haz Cónico/métodos , Anomalías Craneofaciales/diagnóstico , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada de Haz Cónico Espiral/métodos , Adolescente , Adulto , Estudios de Factibilidad , Femenino , Humanos , Masculino , Estudios Prospectivos , Reproducibilidad de los Resultados , Adulto Joven
11.
Clin Oral Investig ; 24(8): 2579-2590, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31848715

RESUMEN

OBJECTIVES: Demineralizations such as white spot lesions are among the most prevalent side effects during orthodontic treatment. Fluorescence devices, including quantitative light-induced fluorescence (QLF), exploiting the intrinsic fluorescence of enamel and teeth and most recently optical coherence tomography (OCT) were introduced for early demineralization detection. In addition to near-infrared OCT scanning, multicolor modules allow for imaging with different laser wavelengths and the detection of reflective- and fluorescent light. The aim of this study was to evaluate a modified multicolor ophthalmic OCT device for the detection of early carious lesions in vitro and in vivo. MATERIALS AND METHODS: Twenty-seven extracted lesion free human teeth were randomly assigned to three different demineralization protocols. Carious lesion detection was performed using macrophotography, OCT, and reflectance/fluorescence imaging using green laser and blue laser light. In addition, teeth of 5 orthodontic patients were OCT scanned, and fluorescence imaging using blue laser light was performed to assess demineralization after orthodontic therapy. RESULTS: Both in vitro and in vivo, OCT allowed for precise determination of lesion depth and enamel loss. Fluorescence imaging using blue laser light was most sensitive for the detection of early demineralization in vitro and in vivo. However, established and severe demineralizations were also reliably detected by macrophotography in vitro and in vivo. CONCLUSION: Demineralization can be detected with high sensitivity using blue fluorescence imaging with multicolor OCT devices. CLINICAL RELEVANCE: In the future, OCT fluorescence imaging might be considered for longitudinal monitoring of dental hard tissue during orthodontic treatment in clinical trials.


Asunto(s)
Ortodoncia , Caries Dental , Esmalte Dental , Humanos , Tomografía de Coherencia Óptica , Desmineralización Dental
12.
Clin Oral Investig ; 24(3): 1339-1349, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31352517

RESUMEN

OBJECTIVE: 3D cephalometric analysis performed on cone-beam or multi-slice computed tomography (CBCT, MSCT) has superior diagnostic value compared to 2D cephalometry based on radiographs. However, this comes at the expense of increased radiation risks for the predominantly young patients. Magnetic resonance imaging (MRI) has the potential to overcome this diagnostic dilemma but has not been established for 3D cephalometry so far. Since landmark reliability forms the basis for 3D cephalometry, we evaluated the in vivo reliability of established 3D landmarks using MRI. MATERIALS AND METHODS: Sixteen orthodontic patients underwent MRI at 3 Tesla using a 0.5 mm 3D sequence. On each MRI scan, 44 cephalometric landmarks were determined. Image analysis was performed twice by two independent observers. Intra- and inter-rater agreement was assessed by mean measurement errors and intraclass correlation coefficients (ICCs). Measurement errors were calculated as Euclidean distances and distances for x-, y-, and z-coordinates. RESULTS: Overall, MRI-based 3D cephalometric landmarks revealed a high reliability comparable to prior in vivo studies using CBCT/MSCT. Intra- and inter-rater ICCs were consistently higher than 0.9. Intra-rater comparisons showed mean measurement differences (ranges) of 0.87 mm (0.41-1.63) for rater I and 0.94 mm (0.49-1.28) for rater II. Average inter-rater difference was 1.10 mm (0.52-2.29). Distinct differences in reliability between the various landmarks were observed, corresponding well with the landmarks' specific shapes. CONCLUSIONS: The present study demonstrates that MRI enables reliable determination of 3D cephalometric landmarks in vivo. CLINICAL RELEVANCE: This study emphasizes the potential of MRI to perform treatment planning and monitoring in orthodontics as well as oral and maxillofacial surgery without radiation exposure.


Asunto(s)
Puntos Anatómicos de Referencia , Cefalometría , Imagenología Tridimensional , Imagen por Resonancia Magnética , Adolescente , Adulto , Tomografía Computarizada de Haz Cónico , Estudios de Factibilidad , Femenino , Humanos , Masculino , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Adulto Joven
13.
J Oral Rehabil ; 47(7): 783-795, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32077514

RESUMEN

BACKGROUND AND OBJECTIVE: The aim of this single-centre, two-arm, parallel-group, double-blinded, randomised controlled trial was to investigate the disputed specific effectiveness of acupuncture by comparing acupuncture on specific and non-specific points among patients with non-chronic, painful TMDs. METHODS: Following predefined eligibility criteria, 49 consecutive patients of both sexes were recruited to the study. All subjects were diagnosed with a non-chronic (Graded Chronic Pain Scale grade <3) painful TMD, as assessed using the Diagnostic Criteria for Temporomandibular Disorders (DC/TMD). Patients were randomly assigned to group A (acupuncture on specific points) or group B (acupuncture on non-specific points) after the initial examination (T0). Both acupuncture treatment sessions were conducted by a trained dentist once a week for four weeks. The examination was repeated five weeks (T5) after T0 by one calibrated examiner who was unaware of the study groups. Characteristic pain intensity (CPI) was evaluated as the main outcome criterion and compared between times and treatment groups by means of non-parametric tests (significance level set at P = .05). Secondary outcomes comprised the maximum corrected active mouth-opening without pain (MAO); patients' expectations regarding acupuncture treatment and pain development; depressivity; and oral health-related quality of life (OHRQoL). RESULTS: A total of 41 patients (38 female) successfully completed the study (mean age: 40.17 ± 16.61). The two groups did not differ significantly at any time in terms of age and CPI. However, CPI was significantly (P < .05) lower at T5 than at T0 for both groups (29.66 and 30.35% lower in group A and group B, respectively). An increase in MAO was observed at T5 for both groups but was significant for group B only (P = .016). All patients had positive expectations of acupuncture therapy, and the two groups did not differ significantly at T5 with regard to the extent to which their expectations had been fulfilled by the treatment (P = .717). Comparison of T0 and T5 showed a statistically significant reduction of depressivity for group A (P = .0205), but no significant change for group B (P = .329). At T5, OHRQoL had improved significantly for both groups (group A, P = .018; group B, P < .001) compared with at T0. CONCLUSIONS: Acupuncture on both specific and non-specific points reduces the non-dysfunctional pain of TMD patients. The effect of acupuncture on painful TMD cannot be attributed to the specific point selection.


Asunto(s)
Terapia por Acupuntura , Dolor Crónico , Trastornos de la Articulación Temporomandibular , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Calidad de Vida , Resultado del Tratamiento , Adulto Joven
14.
Eur J Orthod ; 42(6): 596-604, 2020 Dec 02.
Artículo en Inglés | MEDLINE | ID: mdl-31765473

RESUMEN

BACKGROUND: The integrity of orthodontic surface sealants after professional tooth cleaning (PTC) has previously only been evaluated in vitro. Recently, we have shown that optical coherence tomography (OCT) can successfully be used for the longitudinal assessments of sealant thickness in vitro and in vivo. OBJECTIVES: Thus, the aim of the present study was to assess the sealant thickness after PTC in vitro and in vivo by OCT. TRIAL DESIGN: Single-centre four-arm parallel-group randomized controlled trial. METHODS: Ninety-six extracted human teeth were randomly assigned to the surface sealants Pro Seal® (PS) and Opal® Seal™ (OS) and to PTC protocols: (1) polishing with brush and prophy paste (Cleanic®) or (2) erythritol air-polishing. Sealant thickness was assessed by OCT immediately after application (baseline), after thermocycling and after polishing for totals of 5, 10, 15, 30, 60, 90, and 120 seconds. Additionally, a clinical trial was conducted. Therefore, using a split-mouth design, quadrants of 20 patients and PTC protocols were randomized by an external randomization centre using computer generated tables to assign the surface sealants and PTC protocols. Sealant thicknesses were analysed at baseline, before and after PTC. Due to the optical properties of sealants, a complete blinding was not feasible. RESULTS: In vitro both sealants revealed significant layer thickness losses after both PTC protocols. PS lost 0.77 µm/s [95% CI (confidence interval): 0.67, 0.87] from air-polishing and 0.43 µm/s (95% CI: 0.37, 0.49) from polishing with brush while OS lost 0.44 µm/s (95% CI: 0.32, 0.55) from air-polishing and 0.79 µm/s (95% CI: 0.68, 0.89) from polishing with brush of layer thickness. Sealant thickness loss of was significantly higher after erythritol air-polishing for PS and after polishing with brush for OS. The results of a concurrent randomized controlled trial (RCT) were comparable to those achieved in the in vitro part of this study. LIMITATIONS: Long-term surface sealant abrasion should be validated by additional RCTs. CONCLUSIONS: For PTC on surface sealant treated teeth, low abrasive protocols should be used. Air-polishing should be avoided on PS protected teeth and polishing with brush on OS treated teeth. TRIAL REGISTRATION: ClinicalTrials.gov NCT03753256.

15.
Clin Oral Investig ; 22(9): 3143-3157, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29524024

RESUMEN

OBJECTIVE: Optical coherence tomography (OCT) is a clinical standard in ophthalmology. Currently, its application in dentistry is gaining increasing interest. In this study, we tested the possibility to use a modified commercially available spectral domain OCT (SD-OCT) to assess the layer thickness of orthodontic surface sealants. MATERIALS AND METHODS: Reference samples of surface sealants for calibration and repeatability testing were measured using a micrometer screw. SD-OCT measurements were compared with micro-CT and light microscopic analyses. After validating the calibration of the SD-OCT, surface sealant layer thickness after aging (thermo cycling) and simulation of professional tooth cleaning (PTC) was assessed using the SD-OCT on 45 extracted teeth assigned to three test groups (n = 15 each): Light Bond™ Sealant, Pro Seal®, and Opal® Seal. RESULTS: SD-OCT showed excellent repeatability and accuracy for measurements of surface sealant layer thickness. Compared with micro-CT, SD-OCT showed better accordance with the reference measurements. The analysis of surface sealants after thermo cycling and PTC revealed poor resistance of Light Bond after only aging and demonstrated substantial wear of all sealants after aging and PTC. CONCLUSION: Imaging using commercially available ophthalmic SD-OCT might represent a suitable non-invasive methodology for longitudinal assessments of surface sealant layer thickness in vitro and in vivo. CLINICAL RELEVANCE: SD-OCT might be a suitable non-invasive method for longitudinal assessments of surface sealant durability in clinical trials.


Asunto(s)
Selladores de Fosas y Fisuras/química , Tomografía de Coherencia Óptica/instrumentación , Resinas Compuestas , Humanos , Técnicas In Vitro , Ensayo de Materiales , Reproducibilidad de los Resultados , Cementos de Resina , Propiedades de Superficie , Microtomografía por Rayos X
16.
J Esthet Restor Dent ; 30(6): 580-586, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30394680

RESUMEN

OBJECTIVE: To assess surface discoloration of four enamel sealants based on different chemical compositions after exposure to artificial aging and staining solutions. Furthermore, their cleanability after polishing will be evaluated. MATERIALS AND METHODS: Selected sealants were a composite resin-based sealant with fillers (Pro Seal), a composite resin-based sealant without fillers (Light BondSealant), a resin-modified glass ionomer-based sealant (ClinproXT Varnish) and a silicon-based sealant (Protecto). Natural teeth served as medium. Immersion solutions were water, juice, tea, and turmeric. In a standardized setting, all samples were measured seven times with a spectroradiometer (Photoresearch PR670) at baseline, after thermocycling; 7 days; 2 and 4 weeks of immersion; and after finally polishing. RESULTS: Thermocycling had no significant effect on color stability. After exposure to staining solutions, all sealed surfaces showed significant color changes. Color change predominately occurred for all sealants in the first week of staining (P ≤ .01). Best resistance to staining decreased as follows: Protecto > Light Bond Sealant > ProSeal > Clinpro XT Varnish. Surface cleaning by polishing significantly reduced the color change. CONCLUSION: Sealed enamel surfaces are prone to discoloration, which is most prominent in filled composite and glass-ionomer-based sealants. Staining can be reduced by polishing; however, in this in vitro setting the original color could not be restored. CLINICAL SIGNIFICANCE: Enamel sealants might exert adverse effects in terms of discoloration. This should be taken into consideration by clinicians and patients, particularly when sealants are applied in esthetically critical areas.


Asunto(s)
Esmalte Dental , Selladores de Fosas y Fisuras , Resinas Compuestas , Humanos , Ensayo de Materiales , Coloración y Etiquetado , Propiedades de Superficie
17.
Am J Orthod Dentofacial Orthop ; 151(5): 878-886, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28457265

RESUMEN

INTRODUCTION: Increasing numbers of orthodontic mini-implants are placed in the anterior maxilla. To our knowledge, bone levels and root proximity of patients with cephalometrically short maxillae have not been investigated before. The first, second, and third rugae were used as clinical reference lines, and the aim of this study was to measure bone availability in that area by comparing patients with short and normal maxillary body lengths. METHODS: The sample consisted of 21 patients in each group: short maxillary body length and normal maxillary body length. The patients' study models were bisected, and the outline of the palatal contour was marked on the surface. The models were scanned, and the palatal contours were superimposed on the palatal structures of their respective initial cephalometric headfilms, and the vertical and oblique bone levels of the sagittal plane were compared using the Student t test. The level of significance was set at P <0.05. RESULTS: Compared with maxillae of normal maxillary body length, less bone was available in maxillae of short maxillary body length. However, the differences did not reach clinical or statistical significance (P >0.05) at the third rugae. CONCLUSIONS: Almost equivalent average bone depth at the third rugae in patients with normal and short maxillary body lengths suggests that this site can be used for 8-mm long obliquely inserted orthodontic mini-implants.


Asunto(s)
Puntos Anatómicos de Referencia/anatomía & histología , Maxilar/anatomía & histología , Cefalometría , Niño , Femenino , Humanos , Incisivo/anatomía & histología , Masculino , Modelos Anatómicos , Métodos de Anclaje en Ortodoncia
18.
Clin Oral Investig ; 20(5): 933-42, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26419674

RESUMEN

OBJECTIVE: This aims to evaluate the efficiency of three different powered interproximal enamel reduction (IER) systems and to assess enamel roughness before and after polishing using different polishing times. MATERIAL AND METHODS: Four metal strips of the G5 ProLign Set (swissdentacare, SDC, Grancia, Switzerland), four segmental discs of the ASR-Set 4594 and two sonic tips of the SonicLine Set (both Gebr. Basseler GmbH & Co. KG, Komet, Lemgo, Germany) were evaluated. Human extracted incisors served as the medium. Enamel reduction was determined in five intervals of 15 s each. Polishing was performed for 15 and 30 s using the manufacturers' recommended polishing systems. Enamel roughness (Ra) was quantitatively assessed by confocal laser scanning microscopy (CLSM). RESULTS: Significant differences in terms of enamel reduction were found among the working ends of all tested systems. The time needed to remove 0.1, 0.2 and 0.3 mm of enamel was determined. Surface analysis showed significantly higher mean Ra values for nine out of ten working ends before polishing. This was still the case for five working ends after 15 s and for two after 30 s of polishing. CONCLUSION: The graining and the system used have a significant influence on enamel reduction. The time needed for polishing depends on the last working end used; a polishing time of 30 s is not always appropriate. CLINICAL RELEVANCE: Knowledge about the cutting efficiency of powered IER working ends might help the clinician to estimate better the amount of enamel reduction during the stripping process.


Asunto(s)
Esmalte Dental , Pulido Dental/instrumentación , Humanos , Técnicas In Vitro , Incisivo , Microscopía Confocal , Proyectos Piloto , Propiedades de Superficie
19.
Clin Oral Investig ; 20(9): 2333-2341, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26895154

RESUMEN

OBJECTIVES: Root resorptions are common undesirable side effects of orthodontic treatment. In most patients, these defects are repaired by cementoblasts. However, in 1-5 % of patients, the repair fails. The repair mechanism is not well understood. Apoptosis of cementoblasts might contribute to an impaired repair of root resorptions induced by orthodontic forces. MATERIALS AND METHODS: To gain insight into putative molecular pathways leading to compression-induced apoptosis of human primary cementoblasts (HPCBs), three independent cell populations were subjected to compressive loading at 5, 20, and 30 g/cm2 for 1, 6, and 10 h. The mRNA expression of AXUD1, a novel pro-apoptotic gene, was monitored by quantitative reverse transcription PCR (qRT-PCR). To identify a possible function in compression-dependent apoptosis, AXUD1 was silenced in cementoblasts using an siRNA approach. Apoptosis of cementoblasts was measured by annexin V staining and flow cytometry. The phosphorylation of c-Jun-N-terminal kinases (JNKs) was investigated by Western blotting. RESULTS: AXUD1 was significantly induced in a time- and force-dependent manner. The rate of apoptotic HPCBs increased by 20-40 % after 10 h of compression (30 g/cm2). Phosphorylation of JNKs was detected after 10 h at 30 g/cm2. SiRNA-mediated knockdown of AXUD1 led to decreased phosphorylation of JNKs and reduced apoptosis rates in compressed HPCBs. CONCLUSIONS: Compression-induced apoptosis of HPCBs is mediated by AXUD1 via a JNK-dependent pathway. CLINICAL RELEVANCE: AXUD1-dependent apoptosis of human cementoblasts might contribute to an impaired repair of root resorptions during orthodontic tooth movement. Further studies are needed to develop treatment strategies aiming to minimize root resorption during orthodontic tooth movement.


Asunto(s)
Proteínas Reguladoras de la Apoptosis/antagonistas & inhibidores , Cemento Dental/citología , Cemento Dental/fisiología , Mecanotransducción Celular/fisiología , Apoptosis , Western Blotting , Células Cultivadas , Citometría de Flujo , Humanos , Proteínas Quinasas JNK Activadas por Mitógenos/metabolismo , Fosforilación , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Resorción Radicular/fisiopatología , Estrés Mecánico , Técnicas de Movimiento Dental
20.
Clin Oral Investig ; 18(8): 1925-39, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24407550

RESUMEN

OBJECTIVES: Root resorptions due to a reduced repair function of cementoblasts are common side effects during orthodontic tooth movement (OTM). The mechanisms, which lead to an impaired cementoblast function, are not fully understood. Therefore, we aimed to investigate changes in the gene expression of cementoblasts during mechanical stimulus under inflammatory conditions. MATERIALS AND METHODS: Human primary cementoblasts (HPCB) were exposed to compression for 6 h or stimulation with IL-1ß for 96 h and subsequent 6 h compression. Genome-wide expression analysis was performed using microarray analysis. Prominent gene expression alterations (COX2, AXUD1, FOSB, CCL2, IFI6, and PTGES) were verified by quantitative RT-PCR (qRT-PCR) in two HPCB populations. A caspase 3/7 activity assay was used to determine caspase-3 and caspase-7 activity in stressed cells. RESULTS: Gene expression cluster analysis revealed apoptosis as an important process induced under both conditions. Apoptosis (pro- and anti-apoptotic) related gene expression was most relevant after pro-inflammatory stimulation and compression. qRT-PCR analysis confirmed significant up-regulation of COX2, AXUD1, and FOSB in both HPCB populations after compression, while selected genes significantly increased after pro-inflammatory stimulation and compression. Compression of cementoblasts increased caspase. The combination of pro-inflammatory stimulation and compression led to a slightly smaller increase of caspase activity. CONCLUSIONS: Gene ontology analysis showed that compressed HPCB up-regulate genes that are associated with apoptosis. Combining compression with a pro-inflammatory stimulus (IL-1ß) augmented the positive regulation of apoptosis-related pathways. The induction of apoptosis related gene expression (pro- and anti-apoptotic genes) in cementoblasts suggests an involvement of apoptosis in cementoblast regulation during OTM. CLINICAL RELEVANCE: As apoptosis is induced in HPCB after compression and inflammation, it is conceivable that HPCB cell death might contribute to root resorptions due to a loss of repair activity of cementoblasts. Further studies should be conducted to clarify the implication of the identified genes on root resorptions in order to develop therapeutic strategies to prevent a shortening of roots.


Asunto(s)
Cemento Dental/metabolismo , Perfilación de la Expresión Génica , Interleucina-1beta/administración & dosificación , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA