1.
BMC Musculoskelet Disord ; 23(1): 40, 2022 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-34996409

RESUMEN

BACKGROUND: Intraoperative proximal femoral fractures (IPFF) are relevant complications during total hip arthroplasty. Fixation using cerclage wires (CW) represents a minimally-invasive technique to address these fractures through the same surgical approach. The goal of treatment is to mobilise the patient as early as possible, which requires high primary stability. This study aimed to compare different cerclage wire configurations fixing IPFF with regard to biomechanical primary stability. METHODS: Standardised IPFF (type II, Modified Mallory Classification) were created in human fresh frozen femora and were fixed either by two or three CW (1.6 mm, stainless steel). All cadaveric specimens (n = 42) were randomised to different groups (quasi-static, dynamic) or subgroups (2 CW, 3 CW) stratified by bone mineral density determined by Dual Energy X-ray Absorptiometry. Using a biomechanical testing setup, quasi-static and dynamic cyclic failure tests were carried out. Cyclic loading started from 200 N to 500 N at 1 Hz with increasing peak load by 250 N every 100 cycles until failure occurred or maximum load (5250 N) reached. The change of fracture gap size was optically captured. RESULTS: No significant differences in failure load after quasi-static (p = 0.701) or dynamic cyclic loading (p = 0.132) were found between the experimental groups. In the quasi-static load testing, all constructs resisted 250% of the body weight (BW) of their corresponding body donor. In the dynamic cyclic load testing, all but one construct (treated by 3 CW) resisted 250% BW. CONCLUSIONS: Based on this in vitro data, both two and three CW provided sufficient primary stability according to the predefined minimum failure load (250% BW) to resist. The authors recommend the treatment using two CW because it reduces the risk of vascular injury and shortens procedure time.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Artroplastia de Reemplazo de Cadera/efectos adversos , Fenómenos Biomecánicos , Hilos Ortopédicos , Fracturas del Fémur/cirugía , Fijación Interna de Fracturas/efectos adversos , Humanos
2.
Orthopade ; 50(3): 188-197, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32424439

RESUMEN

BACKGROUND: Malnutrition caused by protein and vitamin deficiencies is a significant negative prognostic factor in surgical wound healing disorders and infections. Particularly in elective surgery, preoperative compensation of deficiencies is advisable to avoid negative postoperative consequences. This study examined the nutritional and protein balance of patients with periprosthetic hip and knee joint infections. MATERIAL AND METHODS: Patients with periprosthetic hip or knee joint infections constituted the study group (SG). Control group I (CG I) included patients with primary implants and CG II included patients who required revision surgery because of aseptic loosening. Relevant nutritional and protein parameters were determined via analysis of peripheral venous blood samples. In addition, a questionnaire was used to evaluate the nutritional and eating patterns of all patients. The nutritional risk screening (NRS) 2002 score and body mass index (BMI) were also calculated for all participants. RESULTS: Differences were found in the albumin level (SG: 36.23 ± 7.34, CG I: 44.37 ± 3.32, p < 0.001, CG II: 44.06 ± 4.24, p < 0.001) and total protein in serum (SG: 65.42 ± 8.66, CG I: 70.80 ± 5.33, p = 0.004, CG II: 71.22 ± 5.21, p = 0.004). The number of patients with lowered albumin levels (SG 19/61, CG I 1/78, CG II 2/55) and total protein in serum (SG: 12/61, CG I 5/78, CG II 2/55) also showed considerable variation. The number of patients with a NRS 2002 score ≥3 differed significantly between SG and both CGs (SG: 5/61, CG I 1/78, CG II 0/55); however, these differences could not be confirmed using BMI. CONCLUSION: As expected, lowered albumin and total protein levels were observed in PJI due to the acute phase reaction. The NRS can be performed to exclude nutritional deficiency, which cannot be excluded based on BMI. In cases of periprosthetic joint infection it is reasonable to compensate the nutritional deficiency with dietary supplements.


Asunto(s)
Artritis Infecciosa , Infecciones Relacionadas con Prótesis , Humanos , Estado Nutricional , Reoperación , Estudios Retrospectivos
3.
Orthopade ; 50(3): 207-213, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32666143

RESUMEN

BACKGROUND: Knee joint arthrodesis is an established treatment for periprosthetic infections (PPI) providing stability and pain relief. In this study the outcome after arthrodesis of the knee joint for persistent infections was compared and evaluated depending on the surgical procedure (intramedullary vs. extramedullary). MATERIAL AND METHODS: In a retrospective case analysis, all patients who underwent knee joint arthrodesis between 1 January 2010 and 31 December 2016 were identified and divided into two groups: IMA and EMA. All patients were examined clinically and radiologically and the patient files were evaluated. In addition, the FIM score, the LEFS, the WHOQOL-BREF and NRS were evaluated. RESULTS: The median LEFS score for the IMA group was 26 points and in the EMA group 2 points (p = 0.03). The IMA patients showed a median pain scale at rest of 0 and during exercise of 2. The EMA group recorded a pain scale of 3 at rest and 5 during exercise (p = 0.28 at rest; p = 0.43 during exercise). In the IMA group the median postsurgical leg length difference was -2.0 cm and -2.5 cm in the EMA group (p = 0.31). At the end of the follow-up examinations, the FIM score of patients in the IMA group was 74.5 points and 22 points in the EMA group (p = 0.07). CONCLUSION: The study showed that no arthrodesis procedure is obviously superior with respect to the postoperative outcome. The IMA combines advantages especially in the early phase after surgery in terms of function as well as patient comfort and is therefore currently the procedure of choice. The attending physician should be familiar with the advantages and disadvantages of the various procedures in order to be able to make an individual decision and thus maximize the chance of treatment success.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Infecciones Relacionadas con Prótesis , Artrodesis , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Infecciones Relacionadas con Prótesis/cirugía , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento
4.
BMC Musculoskelet Disord ; 19(1): 314, 2018 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-30170580

RESUMEN

BACKGROUND: Dislocation following total hip arthroplasty has to date not been resolved satisfactorily. Previous work has shown that using a less-invasive adaption of Bauer's lateral transgluteal approach with capsular repair significantly reduces dislocation rates in primary total hip arthroplasty. The aim of this retrospective cohort study was to assess whether this approach also helps to reduce the dislocation rate in revision total hip arthroplasty. METHODS: We analyzed revision total hip arthroplasty cases performed between 10/2005 and 12/2013 in our department, classifying capsular repair cases as study group and capsular resection cases as control group. The WOMAC score, the dislocations and the revisions were observed. RESULTS: A total of 259 cases were included, 100 in the study group and 159 in the control group. In the 12-month follow-up, dislocation rates were significantly lower in the study group (3%, n = 3) compared to the control group (21.4%, n = 34; p = 0.001). Overall follow-up periods were 49 and 79 months, revision frequencies were 10 and 29%, pain improvements were 5.5 compared to 4.4 and the WOMAC global scores averaged 2.0 ± 2.1 and 2.9 ± 2.6 for the study group and the control group, respectively. CONCLUSION: The modified, less-invasive, lateral transgluteal approach with capsular repair was accompanied by an 86% reduction in dislocation rates when compared to the conventional technique with capsular resection via the anterolateral Watson-Jones-approach. Capsular repair is possible in about 60% of the revision total hip arthroplasty cases, may be considered as beneficial to avoid dislocation and can therefore be recommended.


Asunto(s)
Artroplastia de Reemplazo de Cadera/tendencias , Luxación de la Cadera/diagnóstico por imagen , Liberación de la Cápsula Articular/tendencias , Reoperación/tendencias , Artroplastia de Reemplazo de Cadera/efectos adversos , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Luxación de la Cadera/etiología , Humanos , Liberación de la Cápsula Articular/efectos adversos , Masculino , Reoperación/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
5.
Hum Brain Mapp ; 38(2): 909-922, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27726278

RESUMEN

The subthalamic nucleus (STN) is a main target structure of deep brain stimulation (DBS) in idiopathic Parkinson's disease. Nevertheless, there is an ongoing discussion regarding human STN volumes and neuron count, which could potentially have an impact on STN-DBS. Moreover, a suspected functional subdivision forms the basis of the tripartite hypothesis, which has not yet been morphologically substantiated. In this study, it was aimed to investigate the human STN by means of combined magnetic resonance imaging (MRI) and stereology. STN volumes were obtained from 14 individuals (ranging from 65 to 96 years, 25 hemispheres) in 3 T MRI and in luxol-stained histology slices. Neuron number and cell densities were investigated stereologically over the entire STN and in pre-defined subregions in anti-human neuronal protein HuC/D-stained slices. STN volumes measured with MRI were smaller than in stereology but appeared to be highly consistent, measuring on average 99 ± 6 mm3 (MRI) and 132 ± 20 mm3 (stereology). The neuron count was 431,088 ± 72,172. Both STN volumes and cell count decreased age-dependently. Neuron density was different for the dorsal, medial and ventral subregion with significantly higher values ventrally than dorsally. Small variations in STN volumes in both MRI and stereology contradict previous findings of large variations in STN size. Age-dependent decreases in STN volumes and neuron numbers might influence the efficacy of STN-DBS in a geriatric population. Though the study is limited in sample size, site-dependent differences for the STN subregions form a morphological basis for the tripartite theory. Hum Brain Mapp 38:909-922, 2017. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Envejecimiento , Imagen por Resonancia Magnética , Técnicas Estereotáxicas , Núcleo Subtalámico/citología , Núcleo Subtalámico/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Recuento de Células , Proteína 3 Similar a ELAV/metabolismo , Proteína 4 Similar a ELAV/metabolismo , Femenino , Humanos , Imagenología Tridimensional , Masculino , Neuronas/metabolismo
6.
BMC Musculoskelet Disord ; 18(1): 490, 2017 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-29178860

RESUMEN

BACKGROUND: The treatment aims of periprosthetic fractures (PPF) of the distal femur are a gentle stabilization, an early load-bearing capacity and a rapid postoperative mobilization of the affected patients. For the therapy planning of PPF a standardized classification is necessary which leads to a clear and safe therapy recommendation. Despite different established classifications, there is none that includes the types of prosthesis used in the assessment. For this purpose, the objective of this work is to create a new more extensive fracture and implant-related classification of periprosthetic fractures of the distal femur based on available classifications which allows distinct therapeutic recommendations. METHODS: In a retrospective analysis all patients who were treated in the University Hospital Leipzig from 2010 to 2016 due to a distal femur fracture with total knee arthroplasty (TKA) were established. To create an implant-associated classification the cases were discussed in a panel of experienced orthopaedists and well-practiced traumatologists with a great knowledge in the field of endoprosthetics and fracture care. In this context, two experienced surgeons classified 55 consecutive fractures according to Su et al., Lewis and Rorabeck and by the new created classification. In this regard, the interobserver reliability was determined for two independent raters in terms of Cohen Kappa. RESULTS: On the basis of the most widely recognized classifications of Su et al. as well as Lewis and Rorabeck, we established an implant-dependent classification for PPF of the distal femur. In accordance with the two stated classifications four fracture types were created and defined. Moreover, the four most frequent prosthesis types were integrated. Finally, a new classification with 16 subtypes was generated based on four types of fracture and four types of prosthesis. Considering all cases the presented implant-associated classification (κ = 0.74) showed a considerably higher interobserver reliability compared to the other classifications of Su et al. (κ = 0.39) as well as Lewis and Rorabeck (κ = 0.31). Excluding the cases which were only assessable by the new classification, it still shows a higher interobserver reliability (κ = 0.70) than the other ones (κ = 0.63 or κ = 0.45). CONCLUSIONS: The new classification system for PPF of the distal femur following TKA considers fracture location and implant type. It is easy to use, shows agood interobserver reliability and allows conclusions to be drawn on treatment recommendations. Moreover, further studies on the evaluation of the classification are necessary and planned.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Fracturas del Fémur/clasificación , Fracturas del Fémur/cirugía , Fijación Interna de Fracturas/instrumentación , Artroplastia de Reemplazo de Rodilla/métodos , Fracturas del Fémur/diagnóstico por imagen , Fijación Interna de Fracturas/métodos , Humanos , Reproducibilidad de los Resultados , Estudios Retrospectivos
7.
Neuromodulation ; 20(4): 361-368, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28145065

RESUMEN

OBJECTIVES: The cervical part of the vagus nerve (CVN) has become an important target for stimulation therapy to treat epilepsy and psychiatric conditions. For this purpose, the CVN is visualized in the carotid sheath, assuming it to be localized dorsomedially between the carotid artery (CA) and the internal jugular vein (JV). The aim of our morphological study was therefore to revisit the CVN relationships to the CA and JV, hypothesizing it to have common variations to this classical textbook anatomy. MATERIALS AND METHODS: Positional relations of the CVN, CA and JV were investigated in the carotid sheath of 35 cadavers at the C3 to C6 level. Positional relations of the CVN, CA and JV were documented on the basis of a 3 × 3 chart. RESULTS: Eighteen different arrangements of the CVN, CA and JV were observed. The typical topographic relationship of the CVN dorsomedially between the CA and JV was only found in 42% of all cases. The CVN was located dorsally or (dorso-)laterally to the CA in 80% and dorsally or (dorso-)medially of the JV in 96% of all cases. CONCLUSIONS: Classical textbook anatomy of the CVN is only present in a minority of cases. Positional variations in contrast to textbook anatomy are considerably more frequent than previously described, which might be a hypothetical morphological explanation for the lack of efficacy or side effects of CVN stimulation. Furthermore, the position of the CVN relative to the internal jugular vein is more consistent than to the CA.


Asunto(s)
Arterias Carótidas/anatomía & histología , Plexo Cervical/anatomía & histología , Venas Yugulares/anatomía & histología , Nervio Vago/anatomía & histología , Anciano , Anciano de 80 o más Años , Plexo Cervical/irrigación sanguínea , Femenino , Humanos , Masculino , Nervio Vago/irrigación sanguínea
8.
BMC Musculoskelet Disord ; 17: 149, 2016 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-27048598

RESUMEN

BACKGROUND: To ensure adequate function after orthopedic tumor reconstruction, it is important to reattach the remaining soft tissue to the implant. This study aimed at obtaining mechanical properties of textile muscle-implant and muscle-bone connections in a preliminary test. METHODS: Two groups of soft-tissue attachment were mechanically tested and compared: Native bone-muscle samples obtained from human femora and muscles attached to a prosthetic implant by means of Trevira® attachment tubes. Additionally, muscle samples were tested with muscle fibers aligned parallel and perpendicular to the tension load. A uniaxial load was exerted upon all samples. RESULTS: Failure loads of 26.7 ± 8.8 N were observed for the native bone-muscle group and of 18.1 ± 9.9 N for the Trevira® group. Elongations of 94.8 ± 36.2 % were observed for the native bone-muscle group and 79.3 ± 51.8 % for the Trevira® group. The location of failure was mainly observed in the central area of the muscle fibers. Muscle fibers with parallel fiber orientation (47.6 ± 11.5 N) yielded higher tensile strength than those with perpendicular fiber orientation (14.8 ± 4.1 N). CONCLUSIONS: Our experiments showed that higher forces were transmitted in the origin and insertion areas than in areas of flat soft tissue reconstruction using attachment tubes. The data indicate that the tested material allows reattaching muscles, but without reinforcing the insertion site. Therefore, attachment tubes with region-dependent and potentially anisotropic material behavior might be advantageous to optimize muscle-bone load transmission after surgery, which may allow lower complication rates and shorter physical recovery.


Asunto(s)
Fémur/cirugía , Procedimientos Ortopédicos/instrumentación , Implantación de Prótesis/instrumentación , Músculo Cuádriceps/cirugía , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Cadáver , Fémur/fisiopatología , Humanos , Masculino , Procedimientos Ortopédicos/efectos adversos , Diseño de Prótesis , Implantación de Prótesis/efectos adversos , Músculo Cuádriceps/fisiopatología , Resistencia a la Tracción , Soporte de Peso
9.
J Pers Med ; 14(2)2024 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-38392613

RESUMEN

The use of stereotactic frames is a common practice in neurosurgical interventions such as brain biopsy and deep brain stimulation. However, conventional stereotactic frames have been shown to require modification and adaptation regarding patient and surgeon comfort as well as the increasing demand for individualized medical treatment. To meet these requirements for carrying out state-of-the-art neurosurgery, a 3D print-based, patient-specific stereotactic system was developed and examined for technical accuracy. Sixteen patient-specific frames, each with two target points, were additively manufactured from PA12 using the Multi Jet Fusion process. The 32 target points aim to maximize the variability of biopsy targets and depths for tissue sample retrieval in the brain. Following manufacturing, the frames were measured three-dimensionally using an optical scanner. The frames underwent an autoclave sterilization process prior to rescanning. The scan-generated models were compared with the planned CAD models and the deviation of the planned target points in the XY-plane, Z-direction and in the resulting direction were determined. Significantly lower (p < 0.01) deviations were observed when comparing CAD vs. print and print vs. sterile in the Z-direction (0.17 mm and 0.06 mm, respectively) than in the XY-plane (0.46 mm and 0.16 mm, respectively). The resulting target point deviation (0.51 mm) and the XY-plane (0.46 mm) are significantly higher (p < 0.01) in the CAD vs. print comparison than in the print vs. sterile comparison (0.18 mm and 0.16 mm, respectively). On average, the results from the 32 target positions examined exceeded the clinically required accuracy for a brain biopsy (2 mm) by more than four times. The patient-specific stereotaxic frames meet the requirements of modern neurosurgical navigation and make no compromises when it comes to accuracy. In addition, the material is suitable for autoclave sterilization due to resistance to distortion.

10.
J Neurol Surg B Skull Base ; 85(4): 363-369, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38966300

RESUMEN

Objective The aim of this work was the development of an augmented reality system including the functionality of conventional surgical navigation systems. Methods An application software for the Augmented Reality System HoloLens 2 from Microsoft was developed. It detects the position of the patient as well as position of surgical instruments in real time and displays it within the two-dimensional (2D) magnetic resonance imaging or computed tomography (CT) images. The surgical pointer instrument, including a pattern that is recognized by the HoloLens 2 sensors, was created with three-dimensional (3D) printing. The technical concept was demonstrated at a cadaver skull to identify anatomical landmarks. Results With the help of the HoloLens 2 and its sensors, the real-time position of the surgical pointer instrument could be shown. The position of the 3D-printed pointer with colored pattern could be recognized within 2D-CT images when stationary and in motion at a cadaver skull. Feasibility could be demonstrated for the clinical application of transsphenoidal pituitary surgery. Conclusion The HoloLens 2 has a high potential for use as a surgical navigation system. With subsequent studies, a further accuracy evaluation will be performed receiving valid data for comparison with conventional surgical navigation systems. In addition to transsphenoidal pituitary surgery, it could be also applied for other surgical disciplines.

11.
Acta Vet Scand ; 65(1): 54, 2023 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-38098105

RESUMEN

BACKGROUND: Optical neuronavigation systems using infrared light to create a virtual reality image of the brain allow the surgeon to track instruments in real time. Due to the high vulnerability of the brain, neurosurgical interventions must be performed with a high precision. The aim of the experimental cadaveric study was to determine the application accuracy of a frameless optical neuronavigation system as guide for craniotomies by determining the target point deviation of predefined target points at the skull surface in the area of access to the cerebrum, cerebellum and the pituitary fossa. On each of the five canine cadaver heads ten target points were marked in a preoperative computed tomography (CT) scan. These target points were found on the cadaver skulls using the optical neuronavigation system. Then a small drill hole (1.5 mm) was drilled at these points. Subsequently, another CT scan was made. Both CT data sets were fused into the neuronavigation software, and the actual target point coordinates were identified. The target point deviation was determined as the difference between the planned and drilled target point coordinates. The calculated deviation was compared between two observers. RESULTS: The analysis of the target point accuracies of all dogs in both observers taken together showed a median target point deviation of 1.57 mm (range: 0.42 to 5.14 mm). No significant differences were found between the observers or the different areas of target regions. CONCLUSION: The application accuracy of the described system is similar to the accuracy of other optical neuronavigation systems previously described in veterinary medicine, in which mean values of 1.79 to 4.3 mm and median target point deviations of 0.79 to 3.53 mm were determined.


Asunto(s)
Enfermedades de los Perros , Neuronavegación , Humanos , Perros , Animales , Neuronavegación/métodos , Neuronavegación/veterinaria , Técnicas Estereotáxicas/veterinaria , Procedimientos Neuroquirúrgicos/veterinaria , Craneotomía/veterinaria , Cadáver
12.
Front Neurol ; 14: 1210926, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37645604

RESUMEN

Introduction: Individuals with Parkinsonian disorders often face limited access to specialized physiotherapy and movement training due to staff shortages and increasing disease incidence, resulting in a rapid decline in mobility and feelings of despair. Addressing these challenges requires allocating adequate resources and implementing specialized training programs to ensure comprehensive care and support. Regarding these problems, a computer software was invented that might serve as an additional home-based extension to conventional physiotherapy. Methods: The trial took place in a rehabilitation center where every patient received equivalent treatment apart from the training program that was set up to be investigated over 3 weeks. Seventy four Patients were included and randomized between two intervention and one control group. Intervention group 1 (IG1) trained with the computer-based system two times a week while Intervention group 2 (IG2) received five training sessions a week. Using the markerless Microsoft Kinect® camera, participants controlled a digital avatar with their own body movements. UPDRS-III and Clinical measurements were performed before and after the three-week period. Results: Patients in all groups improved in UPDRS-III pre and post intervention whereas reduction rates were higher for IG1 (-10.89%) and IG2 (-14.04%) than for CG (-7.74%). Differences between the groups were not significant (value of ps CG/IG1 0.225, CG/IG2 0.347). Growth rates for the arm abduction angle were significantly higher in IG1 (11.6%) and IG2 (9.97%) than in CG (1.87%) (value of ps CG/IG1 0.006 and CG/IG2 0.018), as was the 5-steps-distance (CG 10.86% vs. IG1 24.5% vs. UG2 26.22%, value of ps CG/IG1 0.011 and CG/IG2 0.031). Discussion: The study shows the beneficial effects of computer-based training and substantiates the assumption of a similar impact in a home-based setting. The utilized software is feasible for such interventions and meets with the patient's approval. Group dynamics seem to have an additional supporting effect for the aspired objective of improving mobility and should be seen as an essential aspect of video games in therapy.

13.
3D Print Med ; 9(1): 29, 2023 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-37831407

RESUMEN

The aim of the project was to develop a patient-specific stereotactic system that allows simultaneous and thus time-saving treatment of both cerebral hemispheres and that contains all spatial axes and can be used as a disposable product. Furthermore, the goal was to reduce the size and weight of the stereotactic system compared to conventional systems to keep the strain on the patient, who is awake during the operation, to a minimum. In addition, the currently mandatory computed tomography should be avoided in order not to expose the patient to harmful X-ray radiation as well as to eliminate errors in the fusion of CT and MRI data.3D printing best meets the requirements in terms of size and weight: on the one hand, the use of plastic has considerable potential for weight reduction. On the other hand, the free choice of the individual components offers the possibility to optimize the size and shape of the stereotactic system and to adapt it to the individual circumstances while maintaining the same precision. The all-in-one stereotactic system was produced by means of the Multi Jet Fusion process. As a result, the components are highly precise, stable in use, lightweight and sterilizable. The number of individual components and interfaces, which in their interaction are potential sources of error, was significantly reduced. In addition, on-site manufacturing leads to faster availability of the system.Within the project, a patient-specific stereotaxy system was developed, printed, and assembled, which enables the execution of deep brain stimulation via only three bone anchors located on the skull. Pre-developed MRI markers, which can be screwed directly onto the bone anchors via the sleeves, eliminate the need for a CT scan completely. The fusion of the data, which is no longer required, suggests an improvement in target accuracy.

14.
Front Vet Sci ; 9: 876741, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35915727

RESUMEN

Three-dimensional (3D) printing techniques for patient-individual medicine has found its way into veterinary neurosurgery. Because of the high accuracy of 3D printed specific neurosurgical navigation devices, it seems to be a safe and reliable option to use patient-individual constructions for sampling brain tissue. Due to the complexity and vulnerability of the brain a particularly precise and safe procedure is required. In a recent cadaver study a better accuracy for the 3D printed MRI-based patient individual stereotactic brain biopsy device for dogs is determined compared to the accuracies of other biopsy systems which are currently used in veterinary medicine. This case report describes the clinical use of this 3D printed MRI-based patient individual brain biopsy device for brain sampling in three dogs. The system was characterized by a simple handling. Furthermore, it was an effective and reliable tool to gain diagnostic brain biopsy samples in dogs with no significant side effects.

15.
Arthroplasty ; 3(1): 20, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-35236493

RESUMEN

BACKGROUND: All current total hip arthroplasty (THA) systems are modular in design. Only during the operation femoral head and stem get connected by a Morse taper junction. The junction is realized by hammer blows from the surgeon. Decisive for the junction strength is the maximum force acting once in the direction of the neck axis, which is mainly influenced by the applied impulse and surrounding soft tissues. This leads to large differences in assembly forces between the surgeries. This study aimed to quantify the assembly forces of different surgeons under influence of surrounding soft tissue. METHODS: First, a measuring system, consisting of a prosthesis and a hammer, was developed. Both components are equipped with a piezoelectric force sensor. Initially, in situ experiments on human cadavers were carried out using this system in order to determine the actual assembly forces and to characterize the influence of human soft tissues. Afterwards, an in vitro model in the form of an artificial femur (Sawbones Europe AB, Malmo, Sweden) with implanted measuring stem embedded in gelatine was developed. The gelatine mixture was chosen in such a way that assembly forces applied to the model corresponded to those in situ. A study involving 31 surgeons was carried out on the aforementioned in vitro model, in which the assembly forces were determined. RESULTS: A model was developed, with the influence of human soft tissues being taken into account. The assembly forces measured on the in vitro model were, on average, 2037.2 N ± 724.9 N, ranging from 822.5 N to 3835.2 N. The comparison among the surgeons showed no significant differences in sex (P = 0.09), work experience (P = 0.71) and number of THAs performed per year (P = 0.69). CONCLUSIONS: All measured assembly forces were below 4 kN, which is recommended in the literature. This could lead to increased corrosion following fretting in the head-neck interface. In addition, there was a very wide range of assembly forces among the surgeons, although other influencing factors such as different implant sizes or materials were not taken into account. To ensure optimal assembly force, the impaction should be standardized, e.g., by using an appropriate surgical instrument.

16.
Eur J Trauma Emerg Surg ; 47(1): 211-216, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31520158

RESUMEN

INTRODUCTION: In addition to abrasion-induced osteolysis and ensuing instabilities, the polyethylene (PE) abrasion of total hip arthroplasty (THA) inlays can also cause gait instability due to the decentralization of the hip joint. The current literature yields, as yet, insufficient findings whether these two factors are linked directly or indirectly to a higher risk for periprosthetic proximal femoral fractures (PPFF). The aim of our retrospective evaluation is to analyse the impact of PE abrasion on the pathology of PPFF in patients with THA. MATERIAL AND METHODS: The retrospective evaluation comprises all PPFF in patients with THA in the period from 01/2010 up to 12/2016. The study group (SG) included 66 cases (n = 66). The control group (CG) was comprised of patients with asymptomatic THA (n = 66), who were treated by our outpatient department including routine check-ups and X-ray examinations. We used the matched-pair methodology to scale the period of postsurgical care of the CG to the lifetime of the implant up to PPFF in the SG. We included epidemiologic data, radiological femoral head decentralization, osteolysis (Gruen classification), instabilities, acetabular cup position, and implant properties in our analysis. For the SG, we also included intra-operative signs of abrasion. FINDINGS: The SG showed significantly higher numbers of decentralized THA as signs of inlay erosion with 73% compared to only 41% in the CG (p > 0.001). The SG showed 1 ± 0.68 mm hip joint decentralization as to 0.5 ± 0.59 mm in the CG (p = 0.004). We found significantly more cases of osteolysis in the SG (n = 25) than in the CG (n = 13) (p = 0.003). We found no notable differences in acetabular cup inclination or anteversion as well as cup size. However, differences were significant in femoral head size (SG 32 ± 2.3 mm, CG 36 ± 2.4 mm; p = 0.042) and head material. We found more widespread use of metal femoral heads in the SG than in the CG (SG 1:1, CG 1:21; p = 0.001). CONCLUSION: PPFF patients showed significantly higher rates of inlay erosion, resulting in femoral head decentralization and osteolysis. The higher rate of fracture is likely caused by the increasing instability of the implant fixation due to abrasion-induced osteolysis and the associated degradation of bone quality. It is conceivable that the abrasion and decentralization of the THA can also lead to gait instability, and thus, a higher proneness to falls. Gait instability can also be aggravated by increased granulation tissue and effusion due to the inlay abrasion. Although this cannot be substantiated by the investigation. In patients with decentralization of the THA and osteolysis, a radiological follow-up should be performed, and in case of gait instability (femoral head and) inlay replacements should be considered.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur/etiología , Prótesis de Cadera/efectos adversos , Osteólisis/etiología , Polietileno/efectos adversos , Anciano , Femenino , Fracturas del Fémur/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Osteólisis/diagnóstico por imagen , Diseño de Prótesis , Falla de Prótesis , Estudios Retrospectivos
17.
J Med Eng Technol ; 44(2): 69-75, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32077351

RESUMEN

Discrepancy in leg length does frequently occur as a side effect of total hip arthroplasty and may lead to reduced patient satisfaction as well as injury in the sequalae. It is consequently important to reduce leg length discrepancy where-ever technically possible. This may be achieved by recording precise intraoperative measurements and using different sized implanted components. The aim of the given study was to improve the accuracy of a previously validated optic measurement system (OMS) to reduce leg length discrepancy. This pre-existing OMS was first trialled and based on these preliminary findings developed further. Using this improved system, measurements were taken in models and cadavers. Inter observer reliability of the improved OMS was assessed. The system is introduced in the given technical feasibility study. Its accuracy was greater in the model setup (swivel joint: 772.7 ± 1.5 mm; ball joint: 770.0 ± 3.7 mm; reference: 772 mm) compared to the trial using cadaveric tissues (588.8 ± 5.7 mm; reference: 586 mm). Results of two examiners were similar. The third one measured significantly shorter values (p=.011). The results of the measurements with the OMS indicate that a significant increase in accuracy (p = 2.076×10-6) has been achieved compared to the previously reported system, however, a further improvement to measurement accuracy is necessary for this to be applied clinically.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Estudios de Factibilidad , Humanos , Diferencia de Longitud de las Piernas/diagnóstico , Masculino , Satisfacción del Paciente , Reproducibilidad de los Resultados , Programas Informáticos
18.
Arthroplasty ; 2(1): 29, 2020 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-35236465

RESUMEN

INTRODUCTION: Hip and knee arthroplasties are very frequently performed surgeries with high quality standards and continuous optimization potential. Intraoperative processes can be standardized and simplified by optimization of table setups in the operating room to improve the quality and to increase efficiency. PATIENTS AND METHODS: The existing surgical setups for primary hip and knee arthroplasties in a university maximum care hospital with endoprosthesis center were simulated and analysed with a computer program and optimized setup suggestions were worked out, based on handover times, walking distance and ergonomic aspects determined in the program. In a prospective monocentric analysis, primary hip arthroplasties and knee arthroplasties were examined in currently used and in the new optimized setups (standard procedure according to in-house SOP, senior and main surgeons, no assistants). The surgeries were externally and independently supervised and analysed, whereby the time between incision and suture beginning, handovers per minute and handover times were documented, amongst other things. In addition, an evaluation sheet, which showed the satisfaction with the new setup, was filled by the surgical team. RESULTS: In the period from April 2016 to December 2018, 19 hip arthroplasties in currently used and 15 in the new optimized setup as well as 9 knee arthroplasties in currently used and 13 in the new setup were performed. Attention was paid to constant conditions in the compared groups and disruptive factors (assisted surgeries, complex surgeries, different cementings, etc.) were excluded. In the group of hip arthroplasties, the handover times were significantly different (old 1.82 +/- 1.43 s.; new 1.08 +/- 0.78 s.; p <0.001), as well as the handovers per minute (old 1.62 +/- 0.45 handovers/min.; new 2.10 +/- 0.32 handovers/min.; p = 0,001). The time between incision and suture beginning indicated no significant difference (old 53.89 +/- 18.92 min.; new 49.73 +/- 12.18 min; p = 0.466): During the knee arthroplasties, handovers per minute were significantly different (old 1.83 +/- 0.38 handovers/min.; new 2.40 +/- 0.35 handovers/min.; p = 0.002). The time between incision and suture beginning (old 71.11 +/- 20.72 min.; new 70.69 +/- 17.12 min.; p = 0.959) and the handover times (old 1.06 +/- 0.64 s.; new 0.91 +/- 0.59 s.; p = 0.152) indicated no significant difference. The evaluation of the questionnaires showed a significant difference (p < 0.001) in the group of hip arthroplasties in the category "visibility". For the knee arthroplasties, all items except "visibility" (p = 0.261) differed significantly. Overall, a high level of staff satisfaction with the new setup was achieved. CONCLUSIONS: In both groups, more handovers per minute could be achieved in the optimized setup and in the group of the hip arthroplasties, the handover times were significantly faster. The evaluation sheet showed a high satisfaction of the surgical staff with the new setup. No reduction of the time between incision and suture beginning could be determined. This can be attributed to a certain training effect, the adjustment to the setup modification and the low number of cases. The new setup offers a practical alternative for hip arthroplasties as well as for knee arthroplasties as it optimizes the events in the operating room in many ways. For example, there were more handovers per minute possible and passing of the surgical instruments free from interferences. Moreover, it increases the efficiency and achieves a high satisfaction of the staff.

19.
Artículo en Inglés | MEDLINE | ID: mdl-33214984

RESUMEN

Background: Periprosthetic fractures (PPF) of the femur close to the hip joint have serious consequences for most geriatric affected patients. In principle, apart from the highly uncommon conservative therapy, there are two therapeutic options. On the one hand, the prosthesis-preserving treatment by means of osteosynthesis using plates and/or cerclages in general is available. On the other hand, a (partial) change of the prosthesis with optionally additive osteosynthesis or a proximal femoral replacement can be performed because of prosthesis loosening or non-reconstructable comminuted fractures as well as most cemented stem variations. The aim of this retrospective study is the analysis of periprosthetic proximal femoral fractures in the presence of a total hip arthroplasty (THA). The outcome of the operated patients is to be investigated depending on the type of care (osteosynthesis with prosthesis preservation vs. prosthesis change). Material and methods: In a retrospective case analysis, 80 patients with THA and PPF were included. They were divided into two groups. Group I represents the osteosynthetic treatment to preserve the implanted THA (n=42). Group II (n=38) includes those patients who were treated by a change of their endoprosthesis with or without additional osteosynthesis. Specifics of all patients, like gender, age at fracture, interval between fracture and implantation, length of in-patient stay, body mass index, osteoporosis, corticomedullary index and complications such as infections, re-fracture, loosening, material failure or other complications, were recorded and compared. Furthermore, the patients were re-examined by a questionnaire and the score according to Merle d'Aubigné and Postel. Results: In group I the mean follow-up time was 48.5±23 months (4 years) whereas group II amounted 32.5±24.5 months (2.7 years) (p=0.029). Besides, there were significant differences in age (81± 11 years vs. 76±10 years, p=0.047) and length of in-patient stay (14.5±8.6 days vs. 18.0±16.7 days, p=0.014). According to the score of Merle d'Aubigné and Postel, there were significantly better values for the pain in group II with comparable values for mobility and walking ability. Conclusion: The treatment of periprosthetic proximal fractures of the femur is dependent on the classification (Vancouver and Johannsen) and in particular on the prosthetic anchoring as well as the extent of the comminution zone. Older patients and patients with osteoporosis are more frequently treated with an endoprosthesis revision. Patients, who have been treated with an osteosynthesis for preserving their endoprosthesis, showed a shorter length of in-patient stay and fewer complications than people with replacement surgery. In contrast to that, patients with prosthesis revision had better outcomes concerning the score of Merle d'Aubigné and Postel.

20.
J Vet Intern Med ; 34(2): 844-851, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32091636

RESUMEN

BACKGROUND: Brain biopsy of intracranial lesions is often necessary to determine specific therapy. The cost of the currently used stereotactic rigid frame and optical tracking systems for brain biopsy in dogs is often prohibitive or accuracy is not sufficient for all types of lesion. OBJECTIVES: To evaluate the application accuracy of an inexpensive magnetic resonance imaging-based personalized, 3D printed brain biopsy device. ANIMALS: Twenty-two dog heads from cadavers were separated into 2 groups according to body weight (<15 kg, >20 kg). METHODS: Experimental study. Two target points in each cadaver head were used (target point 1: caudate nucleus, target point 2: piriform lobe). Comparison between groups was performed using the independent Student's t test or the nonparametric Mann-Whitney U Test. RESULTS: The total median target point deviation was 0.83 mm (range 0.09-2.76 mm). The separate median target point deviations for target points 1 and 2 in all dogs were 0.57 mm (range: 0.09-1.25 mm) and 0.85 mm (range: 0.14-2.76 mm), respectively. CONCLUSION AND CLINICAL IMPORTANCE: This magnetic resonance imaging-based 3D printed stereotactic brain biopsy device achieved an application accuracy that was better than the accuracy of most brain biopsy systems that are currently used in veterinary medicine. The device can be applied to every size and shape of skull and allows precise positioning of brain biopsy needles in dogs.


Asunto(s)
Neoplasias Encefálicas/veterinaria , Enfermedades de los Perros/diagnóstico por imagen , Técnicas Estereotáxicas/veterinaria , Animales , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/patología , Cadáver , Enfermedades de los Perros/patología , Perros , Imagen por Resonancia Magnética/veterinaria , Linaje , Impresión Tridimensional , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/veterinaria