Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Europace ; 19(3): 447-457, 2017 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-27001035

RESUMEN

AIMS: Transseptal punctures (TSP) are routinely performed in cardiac interventions requiring access to the left heart. While pericardial effusion/tamponade are well-recognized complications, few data exist on accidental puncture of the aorta and its management and outcome. We therefore analysed our single centre database for this complication. METHODS AND RESULTS: We assessed frequency and outcome of inadvertent aortic puncture during TSP in consecutive patients undergoing ablation procedures between January 2005 and December 2014. During the 10-year period, two inadvertent aortic punctures occurred among 2936 consecutive patients undergoing 4305 TSP (0.07% of patients, 0.05% of TSP) and in one Mustard patient during attempted baffle puncture. The first two patients required left ventricular access for catheter ablation of ventricular tachycardia. In both cases, an 11.5F steerable sheath (inner diameter 8.5F) was accidentally placed in the ascending aorta just above the aortic valve. In the presence of surgical standby, the sheaths were pulled back with a wire left in the aorta. Under careful haemodynamic and echocardiographic observation, this wire was also pulled back 30 min later. None of the patients required a closing device or open heart surgery. None of the patients suffered complications from the accidental aortic puncture and sheath placement. CONCLUSION: Inadvertent aortic puncture and sheath placement are rare complications in patients undergoing TSP for interventional procedures. Leaving a guidewire in place during the observation period may allow introduction of sheaths or other tools in order to control haemodynamic deterioration.


Asunto(s)
Aorta/lesiones , Cateterismo Cardíaco/efectos adversos , Catéteres Cardíacos , Ablación por Catéter/efectos adversos , Lesiones del Sistema Vascular/terapia , Anciano , Aorta/diagnóstico por imagen , Aorta/fisiopatología , Cateterismo Cardíaco/instrumentación , Ablación por Catéter/instrumentación , Bases de Datos Factuales , Diseño de Equipo , Femenino , Alemania , Tabiques Cardíacos/diagnóstico por imagen , Hemodinámica , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Punciones , Radiografía Intervencional , Factores de Tiempo , Resultado del Tratamiento , Lesiones del Sistema Vascular/diagnóstico , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/fisiopatología
2.
Ophthalmology ; 123(11): 2294-2299, 2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-27591052

RESUMEN

PURPOSE: The clinical efficacy and toxicity of amiodarone may be determined more effectively by tissue deposition than by levels of the agent in serum. Therefore, corneal densitometry might be useful for therapeutic monitoring. The aim of the study is to evaluate Scheimpflug corneal densitometry in patients with amiodarone keratopathy (AK). DESIGN: Comparative case series. PARTICIPANTS: Sixty-six patients receiving amiodarone therapy and 66 healthy controls were consecutively enrolled in this study. METHODS: Patients were examined using the Oculus Pentacam (Wetzlar, Germany). MAIN OUTCOME MEASURES: Densitometry data from different corneal layers and different annuli were extracted, analyzed, and compared with densitometry values of healthy controls. Duration of treatment, cumulative dose, Orlando stage (slit-lamp biomicroscopy), and serum concentrations of amiodarone and N-desethylamiodarone also were determined, and the correlation to different densitometry data was evaluated. RESULTS: The total corneal light backscatter at total corneal thickness and at total diameter was significantly higher in the amiodarone group compared with the control group (AK group: 28.3±5.2; control group: 24.4±4.2; P < 0.001). Upon dividing the corneal surface into different layers at total thickness, the differences were significant in all layers (P < 0.001). The serum concentrations of the metabolite N-desethylamiodarone correlate with densitometry values, especially in the 0- to 2-mm annulus in the anterior layer (r = 0.419; P = 0.001), whereas the cumulative dose and duration of treatment correlate significantly with the densitometry values in the 0- to 2-mm annulus at total thickness (P = 0.014 and P = 0.022, respectively). CONCLUSIONS: Corneal densitometry is a useful, objective method for quantifying AK and can help in monitoring amiodarone therapy. The serum concentration of the active metabolite N-desethylamiodarone correlates with the extent of keratopathy in the anterior layer, whereas chronic changes in the stroma correlate with the cumulative dose and duration of treatment.


Asunto(s)
Amiodarona/efectos adversos , Arritmias Cardíacas/tratamiento farmacológico , Córnea/patología , Enfermedades de la Córnea/diagnóstico , Densitometría/métodos , Monitoreo Fisiológico/métodos , Adulto , Anciano , Anciano de 80 o más Años , Amiodarona/farmacocinética , Antiarrítmicos/efectos adversos , Antiarrítmicos/farmacocinética , Arritmias Cardíacas/metabolismo , Córnea/efectos de los fármacos , Enfermedades de la Córnea/inducido químicamente , Enfermedades de la Córnea/fisiopatología , Topografía de la Córnea/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados
3.
Europace ; 18(5): 696-701, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26705559

RESUMEN

AIMS: The second-generation multi-electrode-phased radiofrequency pulmonary vein ablation catheter (PVAC GOLD(®)) was redesigned with the intent to improve its safety and efficacy. METHODS AND RESULTS: Using a prospectively designed single-centre database, we retrospectively analysed 128 consecutive patients (102 paroxysmal and 43 female) who underwent their first pulmonary vein isolation with the PVAC GOLD(®). The analysis focused on procedural data as well as in-hospital complications. Baseline characteristics of the patient collective were as follows: mean age 57.9 years, mean CHA2DS2-VASC was 1.73 ± 1.30; structural heart disease was present in seven patients. The PVAC GOLD(®) exhibited procedure durations of 123.1 min ± 27.9, duration of energy delivery was 18.3 min ± 11.4, and fluoroscopy duration was 16.0 min ± 7.7. The redesigned catheter shows major complication [major bleeding, transitory ischaemic attack (TIA), and pericardial tamponade] rates of 2.3% (n = 3). The overall rate of adverse events was 5.4% (n = 7). Bleeding complications were observed in three patients (2.3%), in particular there were two cases (1.6%) of minor bleeding and one case (0.8%) of major bleeding. Two patients suffered pericardial effusion, but there was no need for pericardiocentesis. Besides one TIA, there was no other thrombo-embolic event. Furthermore, one case of post-procedural fever was observed. No deaths, stroke, or haemorrhagic shock occurred. Of the 510 pulmonary veins, 508 could be reached with the PVAC GOLD(®) device using a non-steerable long sheath. CONCLUSION: The PVAC GOLD(®) seems to have an acceptable safety profile. The handling is comparable with the previous generation PVAC(®).


Asunto(s)
Fibrilación Atrial/terapia , Ablación por Catéter/instrumentación , Venas Pulmonares/cirugía , Anciano , Antitrombinas/uso terapéutico , Ablación por Catéter/efectos adversos , Dabigatrán/uso terapéutico , Bases de Datos Factuales , Electrodos Implantados/efectos adversos , Diseño de Equipo , Europa (Continente) , Inhibidores del Factor Xa/uso terapéutico , Femenino , Hemorragia/etiología , Humanos , Ataque Isquémico Transitorio/etiología , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Rivaroxabán/uso terapéutico , Resultado del Tratamiento
4.
Pacing Clin Electrophysiol ; 39(4): 316-20, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26644279

RESUMEN

BACKGROUND: The development of esophageal lesions following atrial fibrillation (AF) ablation has frequently been reported. Mediastinal tissue layers and the posterior wall of the left atrium are in close proximity to the site of ablation. Hence, mucosal lesions might solely represent the "tip of the iceberg." We therefore investigated patients undergoing multielectrode phased radiofrequency (RF) ablation (PVAC®, Medtronic Inc., Minneapolis, MN, USA) for symptomatic AF by radial endosonography (EUS) in conjunction with conventional endoscopy esophago-gastro-duodenoscopy (EGD) to visualize potential mediastinal injuries following pulmonary vein isolation (PVI). METHODS AND RESULTS: Eighteen patients (six women, mean age 52.8 ± 12.8 years, range 32-72 years) underwent PVI using multielectrode phased RF ablation and EGD and EUS following PVI within 48 hours. Postablation periesophageal lesions were detected by EUS in 10 out of 18 patients (56%). Four out of 10 lesions consisted of mild changes like small pericardial effusions, whereas six out of 10 patients had more severe lesions of the mediastinum, including one patient with changes of the esophageal mucosa. No atrio-esophageal fistula developed during follow-up (FU; mean FU 215 ± 105 days). CONCLUSIONS: Mediastinal and esophageal structural changes occurred in a substantial number of patients. These findings highlight the necessity of close FU and the awareness of the potential development of an atrio-esophageal fistula also after multielectrode catheter ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Esófago/lesiones , Mediastino/lesiones , Venas Pulmonares/cirugía , Adulto , Anciano , Fibrilación Atrial/diagnóstico por imagen , Ablación por Catéter/métodos , Esófago/diagnóstico por imagen , Femenino , Humanos , Masculino , Mediastino/diagnóstico por imagen , Persona de Mediana Edad , Venas Pulmonares/diagnóstico por imagen , Resultado del Tratamiento
5.
Cardiol Young ; 25(1): 149-50, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24629166

RESUMEN

Owing to increased life expectancy, patients with grown-up congenital heart disease nowadays present various types of arrhythmias. We report treatment of a 27-year-old patient with tricuspid and pulmonary atresia who was referred to our department with symptomatic tachycardia. During electrophysiologic study, a diagnosis of typical AV-nodal re-entrant tachycardia was made, and he was successfully treated despite the described anatomic malformation.


Asunto(s)
Nodo Atrioventricular/fisiopatología , Ablación por Catéter/métodos , Sistema de Conducción Cardíaco/cirugía , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Atresia Tricúspide/complicaciones , Adulto , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Estudios de Seguimiento , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Masculino , Taquicardia por Reentrada en el Nodo Atrioventricular/etiología , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Atresia Tricúspide/fisiopatología , Atresia Tricúspide/cirugía
6.
Europace ; 16(3): 341-6, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24072443

RESUMEN

AIMS: Phased radiofrequency (RF) ablation for atrial fibrillation is associated with an increased number of silent cerebral lesions on magnetic resonance imaging and cerebral microembolic signals (MESs) on transcranial Doppler ultrasound imaging compared with irrigated RF. The increased rate of embolic events may be due to a specific electrical interference of ablation electrodes attributed to the catheter design. The purpose of this study was to elucidate the effect of deactivating the culprit electrodes on cerebral MESs. METHODS AND RESULTS: Twenty-nine consecutive patients (60 ± 11 years, 10 female) underwent their first pulmonary vein isolation using phased RF energy. Electrode pairs 1 or 5 were deactivated to avoid electrical interference between electrodes 1 and 10 ('modified'). Detection of MESs by transcranial Doppler ultrasound was performed throughout the procedure to assess cerebral microembolism. Results were compared with the numbers of MESs in 31 patients ablated using all available electrodes ('conventional') and to 30 patients undergoing irrigated RF ablation of a previous randomized study. Ablation with 'modified' phased RF was associated with a marked decrease in MESs when compared with 'conventional' phased RF (566 ± 332 vs. 1530 ± 980; P < 0.001). This difference was mainly triggered by the reduction of MES during delivery of phased RF energy, resulting in MES numbers comparable to irrigated RF ablation (646 ± 449; P = 0.7). Total procedure duration as well as time of RF delivery was comparable between phased RF groups. Both times, however, were significantly shorter compared with the irrigated RF group (123 ± 28 vs. 195 ± 38; 15 ± 4 vs. 30 ± 9; P < 0.001, respectively). CONCLUSION: Pulmonary vein isolation with 'modified' phased RF is associated with a decreased number of cerebral microembolism especially during the delivery of ablation impulses, supporting the significance of electrical interference between ablation electrodes 1 and 10. Deactivation of electrode pairs 1 or 5 might increase the safety of this approach without an increase in procedure duration or RF delivery time.


Asunto(s)
Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Embolia Intracraneal/etiología , Embolia Intracraneal/prevención & control , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Femenino , Humanos , Embolia Intracraneal/diagnóstico , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
7.
EClinicalMedicine ; 61: 102052, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37425372

RESUMEN

Background: Endocardial catheter ablation (CA) has limited long-term benefit for persistent and longstanding persistent atrial fibrillation (PersAF/LSPAF). We hypothesized hybrid epicardial-endocardial ablation (HA) would have superior effectiveness compared to CA, including repeat (rCA), in PersAF/LSPAF. Methods: CEASE-AF (NCT02695277) is a prospective, multi-center, randomized controlled trial. Nine hospitals in Poland, Czech Republic, Germany, United Kingdom, and the Netherlands enrolled eligible participants with symptomatic, drug refractory PersAF and left atrial diameter (LAD) > 4.0 cm or LSPAF. Randomization was 2:1 to HA or CA by an independent statistician and stratified by site. Treatment assignments were masked to the core rhythm monitoring laboratory. For HA, pulmonary veins (PV) and left posterior atrial wall were isolated with thoracoscopic epicardial ablation including left atrial appendage exclusion. Endocardial touch-up ablation was performed 91-180 days post-index procedure. For CA, endocardial PV isolation and optional substrate ablation were performed. rCA was permitted between days 91-180. Primary effectiveness was freedom from AF/atrial flutter/atrial tachycardia >30-s through 12-months absent class I/III anti-arrhythmic drugs except those not exceeding previously failed doses. It was assessed in the modified intention-to-treat (mITT) population who had the index procedure and follow-up data. Major complications were assessed in the ITT population who had the index procedure. Thirty-six month follow-up continues. Findings: Enrollment began November 20, 2015 and ended May 22, 2020. In 154 ITT patients (102 HA; 52 CA), 75% were male, mean age was 60.7 ± 7.9 years, mean LAD was 4.7 ± 0.4 cm, and 81% had PersAF. Primary effectiveness was 71.6% (68/95) in HA versus 39.2% (20/51) in CA (absolute benefit increase: 32.4% [95% CI 14.3%-48.0%], p < 0.001). Major complications through 30-days after index procedures plus 30-days after second stage/rCA were similar (HA: 7.8% [8/102] versus CA: 5.8% [3/52], p = 0.75). Interpretation: HA had superior effectiveness compared to CA/rCA in PersAF/LSPAF without significant procedural risk increase. Funding: AtriCure, Inc.

8.
Basic Res Cardiol ; 107(2): 247, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22327339

RESUMEN

The cardiac Na(+)/Ca(2+) exchanger (NCX) generates an inward electrical current during SR-Ca(2+) release, thus possibly promoting afterdepolarizations of the action potential (AP). We used transgenic mice 12.5 weeks or younger with cardiomyocyte-directed overexpression of NCX (NCX-Tg) to study the proarrhythmic potential and mechanisms of enhanced NCX activity. NCX-Tg exhibited normal echocardiographic left ventricular function and heart/body weight ratio, while the QT interval was prolonged in surface ECG recordings. Langendorff-perfused NCX-Tg, but not wild-type (WT) hearts, developed ventricular tachycardia. APs and ionic currents were measured in isolated cardiomyocytes. Cell capacitance was unaltered between groups. APs were prolonged in NCX-Tg versus WT myocytes along with voltage-activated K(+) currents (K(v)) not being reduced but even increased in amplitude. During abrupt changes in pacing cycle length, early afterdepolarizations (EADs) were frequently recorded in NCX-Tg but not in WT myocytes. Next to EADs, delayed afterdepolarizations (DAD) triggering spontaneous APs (sAPs) occurred in NCX-Tg but not in WT myocytes. To test whether sAPs were associated with spontaneous Ca(2+) release (sCR), Ca(2+) transients were recorded. Despite the absence of sAPs in WT, sCR was observed in myocytes of both genotypes suggesting a facilitated translation of sCR into DADs in NCX-Tg. Moreover, sCR was more frequent in NCX-Tg as compared to WT. Myocardial protein levels of Ca(2+)-handling proteins were not different between groups except the ryanodine receptor (RyR), which was increased in NCX-Tg versus WT. We conclude that NCX overexpression is proarrhythmic in a non-failing environment even in the absence of reduced K(V). The underlying mechanisms are: (1) occurrence of EADs due to delayed repolarization; (2) facilitated translation from sCR into DADs; (3) proneness to sCR possibly caused by altered Ca(2+) handling and/or increased RyR expression.


Asunto(s)
Potenciales de Acción/fisiología , Arritmias Cardíacas/metabolismo , Corazón/fisiología , Proteínas de Homeodominio/metabolismo , Miocitos Cardíacos/metabolismo , Animales , Arritmias Cardíacas/genética , Western Blotting , Modelos Animales de Enfermedad , Electrocardiografía , Proteínas de Homeodominio/genética , Ratones , Técnicas de Cultivo de Órganos
9.
Europace ; 14(3): 396-401, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21979994

RESUMEN

AIMS: The use of implantable cardioverter defibrillators (ICD) in patients with torsade de pointes (TdP) and ventricular fibrillation in the presence of acquired long QT syndrome (aLQTS) is under debate, partly due to the fact that aLQTS is potentially reversible and currently no long-term follow-up data are available. We aimed to evaluate the long-term follow-up of patients with acquired long QT syndrome (aLQTS) who had received an implantable cardioverter defibrillator (ICD) for secondary prevention of sudden cardiac arrest (SCA). METHOD AND RESULTS: Over a 10 year period, 43 patients with an ICD after survived cardiac arrest (SCA) due to an aLQTS were included [female n= 27 (63%); mean age 61 ± 16 years]. There was no clinical evidence for congenital LQTS (Schwartz score 1.25 ± 0.8). Structural heart disease was present in 29 patients (47%; ischaemic n= 13; dilated cardiomyopathy n= 9; mean EF 41%± 12). The most common proarrhythmic trigger happened to be antiarrhythmic drugs (n= 34; 79%). Other triggers included contrast agent (n= 1), haloperidol (n= 2), severe hypokalaemia (n= 2), drug abuse/alcohol (n= 2), and mere severe bradycardia (n= 2). Under trigger QTc interval measured 536 ± 58 vs. 438 ± 33 ms without trigger (P< 0.001). During a mean follow-up of 84 ± 55 months, appropriate shocks occurred in 19 patients (44%); inappropriate shocks in 13 patients (30%; only inappropriate n= 3). Appropriate shocks were almost as common in patients without as in those with structural heart disease (35 vs. 48%; P= 0.32). None of the patients were re-exposed to the initial trigger during the follow-up period. Beta-blocker medication did not prevent ICD shocks (12 of 19 vs. 11 of 24 on medication). CONCLUSION: Appropriate ICD shocks are a common finding in patients with aLQTS and SCA irrespective of the underlying cause or structural heart disease. Thus, even in the presence of relevant acquired proarrhythmia ICD may be beneficial.


Asunto(s)
Desfibriladores Implantables , Síndrome de QT Prolongado/terapia , Antagonistas Adrenérgicos beta/uso terapéutico , Adulto , Anciano , Antiarrítmicos/uso terapéutico , Muerte Súbita Cardíaca/prevención & control , Femenino , Estudios de Seguimiento , Cardiopatías/terapia , Humanos , Síndrome de QT Prolongado/tratamiento farmacológico , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Estudios Retrospectivos , Resultado del Tratamiento
11.
BMC Sports Sci Med Rehabil ; 14(1): 120, 2022 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-35787297

RESUMEN

BACKGROUND: To date, no studies on the feasibility or outcomes of cardiac rehabilitation (CR) after percutaneous mitral valve reconstruction using clipping procedures have been published. The aim of this study was to report on our first experiences with this special target group. METHODS: Monocentric retrospective analysis of 27 patients (72 ± 12 years old, 52% female) who underwent multimodal inpatient CR in the first 2 month after MitraClip™ implantation. A six-minute-walking-test, a handgrip-strength-test and the Berg-Balance-Scale was conducted at the beginning and end of CR. Echocardiography was performed to rule out device-related complications. RESULTS: Adapted inpatient CR started 16 ± 13 days after clipping intervention and lasted 22 ± 4 days. In 4 patients (15%) CR had to be interrupted or aborted prematurely due to cardiac decompensations. All other patients (85%) completed CR period without complications. Six-minute-walking-distance improved from 272 ± 97 to 304 ± 111 m (p < .05) and dependence on rollator walker or walking aids was significantly reduced (p < .05). Results of handgrip-strength-test and Berg-Balance-Scale increased (p < .05). Overall, social-medical and psychological consultations were well received by the patients and no device-related complications occurred during rehabilitation treatments. CONCLUSIONS: The results indicate that an adapted inpatient CR in selected patients after MitraClip™ implantation is feasible. Patients benefited from treatments both at functional and social-medical level and no device-related complications occurred. Larger controlled studies are needed.

12.
Circulation ; 122(13): 1272-82, 2010 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-20837891

RESUMEN

BACKGROUND: A rapidly growing number of long-QT syndrome (LQTS) patients are being treated with an implantable cardioverter-defibrillator (ICD). ICDs may pose problems, especially in the young. We sought to determine the characteristics of the LQTS patients receiving an ICD, the indications, and the aftermath. METHODS AND RESULTS: The study population included 233 patients. Beginning in 2002, data were collected prospectively. Female patients (77%) and LQT3 patients (22% of genotype positive) were overrepresented; mean QTc was 516±65 milliseconds; mean age at implantation was 30±17 years; and genotype was known in 59% of patients. Unexpectedly, 9% of patients were asymptomatic before implantation. Asymptomatic patients, almost absent among LQT1 and LQT2 patients, represented 45% of LQT3 patients. Patients with cardiac symptoms made up 91% of all study participants, but only 44% had cardiac arrest before ICD implantation. In addition, 41% of patients received an ICD without having first been on LQTS therapy. During follow-up, 4.6±3.2 years, at least 1 appropriate shock was received by 28% of patients, and adverse events occurred in 25%. Appropriate ICD therapies were predicted by age <20 years at implantation, a QTc >500 milliseconds, prior cardiac arrest, and cardiac events despite therapy; within 7 years, appropriate shocks occurred in no patients with none of these factors and in 70% of those with all factors. CONCLUSIONS: Reflecting previous concepts, ICDs were implanted in some LQTS patients whose high risk now appears questionable. Refined criteria for implantation, reassessment of pros and cons, ICD reprogramming, and consideration for other existing therapeutic options are necessary.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Síndrome de QT Prolongado/terapia , Sistema de Registros , Adolescente , Adulto , Niño , Europa (Continente) , Femenino , Genotipo , Humanos , Síndrome de QT Prolongado/genética , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Adulto Joven
13.
Eur J Nucl Med Mol Imaging ; 38(10): 1899-907, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21691919

RESUMEN

PURPOSE: Increased sympathetic activation is a key modifier for arrhythmogenesis in patients with long QT syndrome (LQTS), a congenital channelopathy. Therefore, we investigated cardiac sympathetic function using 123I-metaiodobenzylguanidine (MIBG) single photon emission computed tomography (SPECT) in a cohort of symptomatic LQTS patients and correlated these findings with the underlying genotype. METHODS: [123I]MIBG SPECT was performed in 28 LQTS patients. Among these, 18 patients (64%) had a previous syncope and 10 patients (36%) survived sudden cardiac arrest. Patients were characterized in terms of genetic subtypes and QTc interval on surface ECGs. SPECT images were analysed for regional [123I]MIBG uptake in a 33-segment bullseye scheme and compared to those obtained from 10 age-matched healthy control subjects (43±12 years). RESULTS: An abnormal 123I-MIBG scan was found in 17 of 28 LQTS patients (61%) with a tracer reduction mainly located in the anteroseptal segments of the left ventricle. This finding was independent of the genetic LQTS subtype. In addition, no differences were found between LQTS patients with a QTc>500 ms vs <500 ms or those suffering from syncope vs VF (p>0.05). CONCLUSION: A distinct regional pattern of impaired cardiac sympathetic function was identified in the majority of symptomatic LQTS patients. This innervation defect was independent of the underlying genotype and clinical disease expression.


Asunto(s)
Corazón/inervación , Síndrome de QT Prolongado/fisiopatología , Sistema Nervioso Simpático/fisiopatología , 3-Yodobencilguanidina , Adulto , Anciano , Estudios de Cohortes , Electrocardiografía , Femenino , Genotipo , Corazón/fisiopatología , Humanos , Síndrome de QT Prolongado/diagnóstico por imagen , Síndrome de QT Prolongado/genética , Síndrome de QT Prolongado/patología , Masculino , Persona de Mediana Edad , Neuronas/diagnóstico por imagen , Neuronas/patología , Sistema Nervioso Simpático/diagnóstico por imagen , Sistema Nervioso Simpático/patología , Tomografía Computarizada de Emisión de Fotón Único , Adulto Joven
14.
Europace ; 13(6): 897-901, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21292648

RESUMEN

Catecholaminergic polymorphic ventricular tachycardia (CPVT) is an inherited arrhythmogenic disease that can cause sudden cardiac death due to ventricular fibrillation (VF). While pharmacological therapy with beta-blockers and/or Ca(2)(+) antagonists is often unreliable, a recent study has demonstrated that flecainide can effectively suppress arrhythmia in a murine model of CPVT as well as clinically in two human subjects suffering from CPVT. We here present the case of an 11-year-old boy suffering from CPVT-1 as well as a review of the current relevant literature. After resuscitation due to VF at age 9, an automated implantable cardioverter-defibrillator (ICD) was implanted in 2007. Under beta-blocker therapy, repeated shocks were delivered due to either fast ventricular tachycardia (VT) or VF. This persisted under additional therapy with verapamil. Implantable cardioverter-defibrillator routine interrogations showed frequent non-sustained VT with an average of 8.8 per day. Additionally, the patient suffered from impaired physical performance due to decreased chronotropic competence. In July 2009, flecainide was added to the beta-blocker/verapamil regimen, resulting in a plasma level of 0.20 mg/L. No ICD shock or sustained VT occurred until December 2010. Genetic testing revealed an RyR2 receptor mutation. The case demonstrates the challenge of diagnosis and management of CPVT. It furthermore supports recent experimental evidence that the class 1 antiarrhythmic drug flecainide can suppress CPVT. The presented case supports a novel strategy in treating CPVT with the class I antiarrhythmic agent flecainide.


Asunto(s)
Antiarrítmicos/uso terapéutico , Flecainida/uso terapéutico , Taquicardia Ventricular/tratamiento farmacológico , Taquicardia Ventricular/genética , Antagonistas Adrenérgicos beta/uso terapéutico , Bloqueadores de los Canales de Calcio/uso terapéutico , Niño , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Quimioterapia Combinada , Electrocardiografía , Humanos , Masculino , Mutación/genética , Canal Liberador de Calcio Receptor de Rianodina/genética , Taquicardia Ventricular/complicaciones , Resultado del Tratamiento , Verapamilo/uso terapéutico
15.
Europace ; 13(10): 1394-400, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21593040

RESUMEN

AIMS: Pulmonary veins (PV) play a pivotal role in atrial fibrillation (AF). Anatomical variants of PV have been described and related to a higher arrhythmogenic potential. The aim of this study was to compare the prevalence of PV variants and diameters of PV ostia in AF patients and controls. METHODS AND RESULTS: Variants of PV were defined as right or left common ostia (RCO, LCO), a right middle or right top PV . A long common trunk (LCT) was defined as an LCO with a distance to the first branching ≥ 10 mm. Multislice contrast-enhanced thoracic computed tomography was performed prior to AF ablation in 166 consecutive patients, 47.6% with paroxysmal, 52.4% with persistent AF, as well as in a sex- and age-matched control group without AF, for non-cardiological indications. Images were evaluated by two independent observers. The mean age was 59 ± 10 years, 108 were men (65.1%). A higher prevalence of LCO was found in the AF group: 33.7 vs. 19.9% (P= 0.004), odds ratio (OR) 2.1; 15.4% in patients vs. 10.2% in controls had an LCT (P= 0.14). No differences in other PV variants were found. The ostial diameters were greater in AF-patients (P< 0.001). CONCLUSIONS: To the best of our knowledge, the present study shows for the first time a higher prevalence of an LCO in patients with AF as compared with controls, with an OR of 2.1. This suggests a pre-disposing role of LCO in the development of AF.


Asunto(s)
Fibrilación Atrial/epidemiología , Venas Pulmonares/anomalías , Venas Pulmonares/diagnóstico por imagen , Anciano , Estudios de Casos y Controles , Causalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Factores de Riesgo , Tomografía Computarizada Espiral
16.
Eur Heart J Case Rep ; 5(5): ytab097, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-34013160

RESUMEN

BACKGROUND: A rare, but serious, complication following transcatheter aortic valve replacement (TAVR) is the occurrence of an iatrogenic ventricular septal defect (VSD). CASE SUMMARY: We describe a case of an 80-year-old female who was referred with severe aortic stenosis for TAVR. Following thorough evaluation, the heart team consensus was to proceed with implantation via a transapical approach of an ACURATE neo M 25 mm valve (Boston Scientific, Natick, MA, USA). The valve was deployed harnessing transoesophageal echocardiographic (TOE) guidance under rapid pacing with post-dilation. Directly afterwards a very high VSD close to the aortic annulus was detected. As the patient was haemodynamically stable, the procedure was ended. The next day another TOE revealed a shunt volume (left-to-right ventricle) between 50% and 60%. Because the defect was partly located between the stent struts of the ACURATE valve decision was made to fix this leakage with implantation of a further valve and we chose an EVOLUT Pro 29 mm (Medtronic Inc., Minneapolis, MN, USA). The valve-in-valve was implanted 2-3 mm below the lower edge of the first valve, more towards the left ventricular outflow tract (LVOT) with excellent result: VSD was reduced to a very small residual shunt without any hemodynamic relevance. Figure 3(A) Fluoroscopic image after transapical transcatheter aortic valve replacement (ACURATE neo M); (B) transoesophageal echocardiography following transapical transcatheter aortic valve replacement showing a severe ventricular septal defect; (C) angiography after valve-in-valve implantation. The implantation depth of the second valve (EVOLUT Pro 29 mm) was slightly deeper in the left ventricular outflow tract; and (D) transoesophageal echocardiography after the valve-in-valve procedure showing a small residual shunt. (1) Stentstruts, (2) tricuspid valve, and (3) leakage (ventricular septal defect). *Pulmonary artery catheter, #Pleural drain.Figure 4Left ventricular angiogram after valve-in-valve implantation showing a very small residual contrast shunt from the left-to-right ventricle (encircled). *Pulmonary artery catheter, # Pleural drain. DISCUSSION: We suggest that an iatrogenic VSD located near the annulus may be treated percutaneously in a bail-out situation with implantation of a second valve that should be implanted slightly more into the LVOT to cover the VSD.

18.
Eur Heart J Case Rep ; 4(6): 1-7, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33447705

RESUMEN

BACKGROUND: Accelerated idioventricular rhythm (AIVR) is known as reperfusion arrhythmia in the setting of acute myocardial infarction (AMI). In healthy individuals, it is usually considered to be benign. Alternating bundle branch block (ABBB) often progresses to complete atrioventricular block requiring permanent pacemaker implantation. We report a case of delayed appearance of AIVR following myocardial infarction (MI) in combination with ABBB as precursor of sudden cardiac arrest due to ventricular fibrillation (VF). CASE SUMMARY: A 62-year-old male with pre-existing left bundle branch block (LBBB) was admitted with an acute non-ST segment elevation MI. He underwent successful percutaneous coronary intervention (PCI) of a subtotal proximal left anterior descending artery (LAD) stenosis. Before and after PCI the electrocardiogram (ECG) demonstrated sinus rhythm with LBBB. The patient was discharged 5 days after PCI, left ventricular function at this time was moderately reduced (ejection fraction of 40%). After another 5 days, the patient was admitted for elective cardiac rehabilitation. At this time, the ECG demonstrated an AIVR with right bundle branch block morphology. Due to ABBB, the patient was scheduled for permanent pacemaker implantation. Before pacemaker implantation could take place, the patient developed a sudden cardiac arrest due to VF and was successfully resuscitated. A follow-up coronary angiography revealed no novel lesions. A cardiac resynchronization therapy defibrillator was implanted for secondary prevention of sudden cardiac death. DISCUSSION: Delayed occurrence of AIVR in combination with ABBB following AMI could be a predictor of sudden cardiac death. These patients are probably at high risk for malignant ventricular arrhythmias.

19.
J Cardiovasc Electrophysiol ; 20(4): 401-7, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19017345

RESUMEN

BACKGROUND: The long-QT syndromes (LQTS) are inherited electrical cardiomyopathies characterized by prolonged ventricular repolarization and ventricular arrhythmias. Several genetic reports have associated defects in LQTS-causing genes with atrial fibrillation (AF). We therefore studied whether atrial arrhythmias occur in patients with LQTS under daily-life conditions. METHODS: We systematically assessed atrial arrhythmias in LQTS patients and matched controls using implanted defibrillators or pacemakers as monitors of atrial rhythm in a nested case-control study. Twenty-one LQTS patients (3 male; 39 +/- 18 years old; 18 on beta blocker, ICD therapy duration 6.3 +/- 2.7 years; 4 LQT1, 6 LQT2, 2 LQT3) were matched to 21 control subjects (13 male; 50 +/- 19 years old; 3 on beta blocker; pacemaker therapy duration 8.5 +/- 5.5 years; 19 higher-degree AV block, 2 others). LQTS patients were identified by a systematic search of the LQTS patient databases in Münster and Munich. RESULTS: One-third (7 of 21) of the LQTS patients developed self-terminating atrial arrhythmias (atrial cycle lengths <250 ms). Only one control patient developed a single episode of postoperative AF (P < 0.05 vs LQTS). CONCLUSIONS: LQTS patients at high risk for ventricular arrhythmias may develop short-lasting atrial arrhythmias under daily-life conditions, suggesting that prolonged atrial repolarization may contribute to the initiation of AF.


Asunto(s)
Actividades Cotidianas , Antagonistas Adrenérgicos beta/uso terapéutico , Fibrilación Atrial/genética , Desfibriladores Implantables , Síndrome de QT Prolongado/genética , Marcapaso Artificial , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/prevención & control , Estudios de Casos y Controles , Niño , Electrocardiografía , Femenino , Alemania , Humanos , Síndrome de QT Prolongado/complicaciones , Síndrome de QT Prolongado/tratamiento farmacológico , Síndrome de QT Prolongado/terapia , Masculino , Persona de Mediana Edad , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
20.
Europace ; 11(1): 42-7, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19029130

RESUMEN

AIMS: Catheter ablation of isthmus-dependent atrial flutter is technically demanding in some patients and extremely simple in others. The intervention targets a defined anatomical structure, the so-called cavotricuspid isthmus (CTI). We sought to characterize CTI anatomy in vivo in patients with difficult and simple catheter ablation of atrial flutter. METHODS AND RESULTS: Twenty-six patients were studied. Seven patients with difficult (n = 6) or extremely simple (n = 1) CTI ablation procedures were retrospectively selected from our catheter ablation database. Thereafter, we prospectively studied 19 patients undergoing CTI ablation in our department. We visualized CTI anatomy by ECG- and respiration-gated free precession 1.5 T cardiac magnetic resonance imaging (MRI). Magnetic resonance imaging was analysed for systolic and diastolic CTI length, the angle between the vena cava inferior and CTI, and pouch-like recesses. These parameters were compared between patients with difficult and simple procedures, split by the median number of energy applications. Patients with difficult procedures had a longer diastolic CTI length (diastolic isthmus length 20.3 +/- 1.8 mm) than those with simple procedures (diastolic isthmus length 16.6 +/- 1.7 mm, all data as mean +/- SEM, P < 0.05). Cavotricuspid isthmus angulation with respect to inferior vena cava was closer to 90 degrees in patients with difficult procedures (deviation from 90 degrees: 15 +/- 2 degrees) than those with simple procedures (deviation 23 +/- 4 degrees, P < 0.05). Systolic CTI length was not different between groups (32 +/- 2 mm in both groups, P > 0.2). CONCLUSION: Longer diastolic, but not systolic, CTI length and a rectangular angle between CTI and inferior vena cava render CTI catheter ablation difficult. Visualization of isthmus anatomy may help to guide difficult CTI ablation procedures.


Asunto(s)
Aleteo Atrial/patología , Aleteo Atrial/cirugía , Ablación por Catéter/métodos , Sistema de Conducción Cardíaco/patología , Sistema de Conducción Cardíaco/cirugía , Imagen por Resonancia Magnética/métodos , Cirugía Asistida por Computador/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Cuidados Preoperatorios/métodos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA