J Am Soc Mass Spectrom ; 16(10): 1708-12, 2005 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16095911

RESUMEN

A modified ion funnel is described. Counterintuitively, increased spacing between electrodes results in enhanced "focusing" of the ions through the funnel. Consequently, the internal diameter (i.d.) of the funnel need not decrease to the conductance limit (as in previous designs). A simple dc-only lens, which also serves as the conductance limit, combined with the natural flow of gas is used to extract the ions from the funnel. Ions with mass to charge ratios varying between 75 and 3000 m/z are passed through the funnel with no apparent discrimination. The funnel can be operated under mild conditions that preserve weakly bound noncovalent complexes. After testing several designs, a thin closely spaced dc lens was found to be the best solution for extracting ions. A simple method for simulating ion trajectories at nonzero pressures based on ion mobility and explicit diffusion is described. This theoretical approach was used to design and calculate ion trajectories for the modified funnel presented here. Finally, the increased spacing between electrodes in the current funnel significantly relaxes machining constraints, reduces cost, and enhances ease of use versus previous funnel designs.


Asunto(s)
Electroquímica/instrumentación , Electrodos , Modelos Químicos , Espectrometría de Masa por Ionización de Electrospray/instrumentación , Simulación por Computador , Electroquímica/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Estudios de Factibilidad , Espectrometría de Masa por Ionización de Electrospray/métodos
2.
Arthritis Rheum ; 58(12): 3765-75, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19035474

RESUMEN

OBJECTIVE: To evaluate the ability of SNX-7081, a novel small molecule inhibitor of Hsp90, to block components of inflammation, including cytokine production, protein kinase activity, and angiogenic signaling. A close analog was evaluated in preclinical in vivo models of rheumatoid arthritis (RA). METHODS: SNX-7081 binding to Hsp90 was characterized in Jurkat cells and RA synovial fibroblasts (RASFs). Inhibition of NF-kappaB nuclear translocation was evaluated in cellular systems, using lipopolysaccharide (LPS), tumor necrosis factor alpha, or interleukin-1beta stimulation. Suppression of cytokine production in THP-1 cells, human umbilical vein endothelial cells, and RASFs was studied. Disruption of MAPK signaling cascades by SNX-7081 following growth factor stimulation was assessed. SNX-7081 was tested in 2 relevant angiogenesis assays: platelet-derived growth factor activation of fibroblasts and LPS-induced nitric oxide (NO) release in J774 macrophages. A close analog, SNX-4414, was evaluated in rat collagen-induced arthritis and adjuvant-induced arthritis, following oral treatment. RESULTS: SNX-7081 showed strong binding affinity to Hsp90 and expected induction of Hsp70. NF-kappaB nuclear translocation was blocked by SNX-7081 at nanomolar concentrations, and cytokine production was potently inhibited. Growth factor activation of ERK and JNK signaling was significantly reduced by SNX-7081. NO production was also sharply inhibited. In animal models, SNX-4414 fully inhibited paw swelling and improved body weight. Scores for inflammation, pannus formation, cartilage damage, and bone resorption returned to normal. CONCLUSION: The present results demonstrate that a small molecule Hsp90 inhibitor can impact inflammatory disease processes. The strong in vivo efficacy observed with SNX-4414 provides preclinical validation for consideration of Hsp90 inhibitors in the treatment of RA.


Asunto(s)
Antiinflamatorios/farmacología , Artritis Reumatoide/tratamiento farmacológico , Artritis Reumatoide/metabolismo , Benzamidas/farmacología , Proteínas HSP90 de Choque Térmico/antagonistas & inhibidores , Transducción de Señal/efectos de los fármacos , Administración Oral , Animales , Antiinflamatorios/farmacocinética , Artritis Reumatoide/inmunología , Benzamidas/farmacocinética , Citocinas/metabolismo , Modelos Animales de Enfermedad , Regulación hacia Abajo/efectos de los fármacos , Regulación hacia Abajo/inmunología , Femenino , Fibroblastos/citología , Proteínas del Choque Térmico HSP72/metabolismo , Humanos , Células Jurkat , Macrófagos/citología , Masculino , Ratones , Proteínas Quinasas Activadas por Mitógenos/metabolismo , FN-kappa B/metabolismo , Células 3T3 NIH , Neovascularización Fisiológica/fisiología , Óxido Nítrico/metabolismo , Ratas , Ratas Endogámicas Lew , Ratas Sprague-Dawley , Transducción de Señal/inmunología , Membrana Sinovial/citología , omega-Conotoxinas
3.
Anal Chem ; 79(22): 8431-9, 2007 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-17929878

RESUMEN

We describe a new approach to measuring the masses of individual macroions. The method employs a pulsed acceleration tube located between two sensitive image charge detectors. The charge and velocity of the macroion are recorded with the first image charge detector. The ion is pulse accelerated through a known voltage drop, and then the charge and velocity are remeasured using the second image charge detector. The mass of the ion is deduced from its charge and its initial and final velocities. The approach has been used to measure masses in the 10(10)-10(14) Da range with z = 10(3)-10(6) and m/z = 10(6)-10(9). It should be extendable to masses of <10(6) Da. We have used the method to determine the size and charge of water droplets transmitted through a capillary interface and an aperture interface. The droplets detected from the aperture interface are approximately 1 order of magnitude smaller in mass than those detected from the capillary interface. The droplets from both interfaces have relatively low charges, particularly with the capillary interface where they are only charged to a small fraction of the Rayleigh limit. These results suggest that the aerodynamic breakup of the droplets plays a significant role in the mechanism of electrospray ionization.