Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Soft Matter ; 16(38): 8871-8876, 2020 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-33026038

RESUMEN

Anisotropic nanomaterials are non-spherical structures that possess unique shape-dependent physicochemical properties and functionalities. Inspired by the abundance of filamentous entities in nature, cylindrical nanostructures have gained significant attention due to their unique performance. Herein, we discuss the effect of side-chain length on the encapsulation properties of amphiphilic heterografted bottlebrushes. We observed that by grafting a long hydrophilic block to the double-brush, we were able to restrict solute-induced conformational changes, thus producing drug-loaded anisotropic carriers. Unimolecular encapsulation in brushes was solute-dependent as shown here for probucol and rose bengal lactone. Stabilization with an amphiphilic diblock copolymer-consisting of the same type of blocks as those comprising the heterografted brush-served to explain the solute-dependent behavior observed for brushes, suggesting that solutes with a higher propensity to nucleation could be more effectively stabilized by the anisotropic carrier in a unimolecular worm-like construct.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38695355

RESUMEN

Flow mediated dilation (FMD) is a common measure of endothelial function and an indicator of vascular health. Automated software methods exist to improve the speed and accuracy of FMD analysis. Compared to commercial software, open-source software offers similar capabilities at a much lower cost while allowing for increased customization specific to users' needs. We introduced modifications to an existing open-source software, FloWave.us to better meet FMD analysis needs. The purpose of this study was to compare the repeatability and reliability of the modified FloWave.us software to the original software and to manual measurements. To assess these outcomes, Duplex ultrasound imaging data from the popliteal artery in older adults were analyzed. The average percent FMD for the modified software was 6.98±3.68% and 7.27±3.81% for Observer 1 and 2 respectively, compared to 9.17±4.91% and 10.70±4.47% with manual measurements and 5.07±31.79% with the original software for Observer 1. The modified software and manual methods demonstrated higher intra-observer intraclass correlation coefficients (ICCs) for repeated measures for baseline diameter, peak diameter, and percent FMD compared to the original software. For percent FMD, the inter-observer ICC was 0.593 for manual measurements and 0.723 for the modified software. With the modified method an average of 97.7±2.4% of FMD videos frames were read, compared to only 17.9±15.0% frames read with the original method when analyzed by the same observer. Overall, this work further establishes open-source software as a robust and viable tool for FMD analysis and demonstrates improved reliability compared to the original software.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA