Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 89
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 35(4): 694-700, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38332493

RESUMEN

INTRODUCTION: Management of transvenous leads in patients with congenital heart disease (CHD) can be complicated by venous obstructions and residual shunts. We present our experience performing concurrent lead extraction and dilation/stenting of venous pathways, including patients with complete venous obstruction. METHODS: All cases of concurrent lead extraction and recanalization of vena cavae/baffles between 2017 and 2021 at Boston Children's Hospital were retrospectively included and reviewed for safety and efficacy. RESULTS: Eight patients, 4 female, median 38.5 years of age (range 16.7-49 years) and 81.6 kg weight (range 41.3-97.8 kg) at time of procedure were included. All patients had CHD, a majority (n = 7) having transposition of the great arteries palliated via atrial switch. All leads were removed in their entirety, with most patients having two leads extracted (n = 7). Median lead dwell time was 13.8 years (range 3.6-35.3 years). Three patients had complete obstructions, three required stenting of their innominate veins and three required recanalization of their femoral vessels. Median procedure time was 9.8 h (range 5.4-12.8 h). Complications included blood transfusion (n = 2), arrhythmia (n = 3), pleural effusion (n = 1), and pressure ulcer (n = 1). There were no cardiac perforations, venous tears, or deaths. CONCLUSION: Lead extraction along with dilation and stenting of venous anomalies, though long in duration, proved effective with minimal complications. This combined procedure can safely and effectively resolve complete obstructions secondary to transvenous leads.


Asunto(s)
Cardiopatías Congénitas , Transposición de los Grandes Vasos , Enfermedades Vasculares , Malformaciones Vasculares , Niño , Humanos , Femenino , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Dilatación , Estudios Retrospectivos , Remoción de Dispositivos/efectos adversos , Remoción de Dispositivos/métodos , Resultado del Tratamiento
2.
Pediatr Cardiol ; 45(1): 114-120, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38036754

RESUMEN

Cardiac implantable electronic device (CIED) remote transmissions are an integral part of longitudinal follow-up in pediatric and adult congenital heart disease (ACHD) patients. To evaluate baseline CIED remote monitoring (RM) data among pediatric and ACHD centers prior to implementation of a Pediatric and Congenital Electrophysiology  Society (PACES)-sponsored quality improvement (QI) project. This is a cross-sectional study of baseline CIED RM. Centers self-reported baseline data: individual center RM compliance was defined as high if there was > 80% achievement and low if < 50%. A total of 22 pediatric centers in the USA and Australia submitted baseline data. Non-physicians were responsible for management of the RM program in most centers: registered nurse (36%), advanced practice provider (27%), combination (23%), and third party (9%). Fifteen centers (68%) reported that > 80% of their CIED patients are enrolled in RM and only two centers reported < 50% participation. 36% reported high compliance of device transmission within 14 days of implant and 77% of centers reported high compliance of CIED patients enrolled in RM. The number of centers achieving high compliance differed by device type: 36% for pacemakers, 50% for ICDs, and 55% for Implantable Cardiac Monitors (ICM). All centers reported at least 50% adherence to recommended follow-up for PM and ICD, with 23% low compliance rate for ICMs. Based on this cross-sectional survey of pediatric and ACHD centers, compliance with CIED RM is sub-optimal. The PACES-sponsored QI initiative will provide resources and support to participating centers and repeat data will be evaluated after PDSA cycles.


Asunto(s)
Desfibriladores Implantables , Cardiopatías Congénitas , Marcapaso Artificial , Niño , Humanos , Adulto , Cardiopatías Congénitas/terapia , Estudios Transversales , Mejoramiento de la Calidad , Tecnología de Sensores Remotos
3.
J Cardiovasc Electrophysiol ; 34(9): 1828-1834, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37449445

RESUMEN

INTRODUCTION: Accessory atrioventricular pathways (APs) may mediate atrioventricular reciprocating tachycardia and, in some cases, have the potential to conduct atrial tachycardia rapidly, which can be life threatening. While catheter ablation can be curative, ablation of right free wall APs is associated with a high rate of recurrence, likely secondary to reduced catheter stability along the right free wall atrioventricular groove. We sought to identify characteristics associated with a lower rate of recurrence and hypothesized ablation lesions placed on the ventricular side of the atrioventricular groove using a retroflexed catheter approach would decrease rates of recurrence. METHODS AND RESULTS: Retrospective chart review of patients who underwent catheter ablation of a right free wall AP from January 1, 2008 through June 1, 2021 with >2 months follow up. Cox proportional hazards regression was used to identify relationships between predictor variables and AP recurrence. We identified 95 patients who underwent ablation of 98 right free wall APs. Median age was 13.1 years and median weight at ablation was 52.3 kg. Overall, 23/98 (23%) APs recurred. Use of a retroflexed catheter course approaching the atrioventricular groove from the ventricular aspect was associated with reduced risk of AP recurrence with (univariable hazard ratio of 0.10 [95% confidence interval: 0.01-0.78]), which remained significant in multiple two variable Cox proportional hazards models. CONCLUSION: Use of a retroflexed catheter course is associated with a reduced likelihood of AP recurrence. This approach results in improved catheter stability and should be considered for ablation of right free wall APs.


Asunto(s)
Fascículo Atrioventricular Accesorio , Ablación por Catéter , Tabique Interventricular , Síndrome de Wolff-Parkinson-White , Humanos , Adolescente , Estudios Retrospectivos , Fascículo Atrioventricular , Fascículo Atrioventricular Accesorio/cirugía , Catéteres , Ablación por Catéter/efectos adversos
4.
J Cardiovasc Electrophysiol ; 34(12): 2545-2551, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37846208

RESUMEN

INTRODUCTION: The use of flecainide and propafenone for medical cardioversion of atrial fibrillation (AF) and atrial flutter/intra-atrial reentrant tachycardia (IART) is well-described in adults without congenital heart disease (CHD). Data are sparse regarding their use for the same purpose in adults with CHD and in adolescent patients with anatomically normal hearts and we sought to describe the use of class IC drugs in this population and identify factors associated with decreased likelihood of success. METHODS: Single center retrospective cohort study of patients who received oral flecainide or propafenone for medical cardioversion of AF or IART from 2000 to 2022. The unit of analysis was each episode of AF/IART. We performed a time-to-sinus rhythm analysis using a Cox proportional hazards model clustering on the patient to identify factors associated with increased likelihood of success. RESULTS: We identified 45 episodes involving 41 patients. As only episodes of AF were successfully cardioverted with medical therapy, episodes of IART were excluded from our analyses. Use of flecainide was the only factor associated with increased likelihood of success. There was a statistically insignificant trend toward decreased likelihood of success in patients with CHD. CONCLUSIONS: Flecainide was more effective than propafenone. We did not detect a difference in rate of conversion to sinus rhythm between patients with and without CHD and were likely underpowered to do so, however, there was a trend toward decreased likelihood of success in patients with CHD. That said, medical therapy was effective in >50% of patients with CHD with AF.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Cardiopatías Congénitas , Taquicardia Supraventricular , Adulto , Adolescente , Humanos , Antiarrítmicos/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/inducido químicamente , Flecainida/efectos adversos , Propafenona/efectos adversos , Cardioversión Eléctrica/efectos adversos , Estudios Retrospectivos , Taquicardia Supraventricular/inducido químicamente , Aleteo Atrial/diagnóstico , Aleteo Atrial/tratamiento farmacológico , Taquicardia , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/terapia
5.
Pediatr Cardiol ; 43(4): 784-789, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34851446

RESUMEN

Decreased physical activity is associated with cardiovascular, metabolic and mental health disease. While decreases in physical activity during the COVID-19 pandemic have been described in the general population, there is a paucity of data regarding children with underlying cardiovascular disease. We hypothesized there would be a decrease in physical activity at the onset of the COVID-19 pandemic. Performed a single-center, retrospective cohort study of children aged < 19 years with cardiac rhythm management devices. Patients were included if they had device-measured physical activity data from > 80% of dates from February 3, 2020 through June 30, 2020. Patients with significant neurologic/neuromuscular disease were excluded. We identified 144 patients with a median age of 15.4 years. 47% were female. 34% had congenital heart disease, 20% had cardiomyopathy, 19% had an inherited arrhythmia syndrome and 5% had atrioventricular block without congenital heart disease. 47% of patients had an implantable loop recorder, 29% had a permanent pacemaker and 24% had an implantable cardioverter-defibrillator. We observed a significant decrease in device-measured physical activity from baseline (February 3-March 9), with up to a 21% decrease in physical activity during mid-March through early May. Activity levels returned to pre-pandemic levels in June. Physical activity sharply declined in children with cardiac rhythm management devices at the onset of the COVID-19 pandemic. These data highlight the importance of finding strategies to maintain physical activity during the current pandemic and future public health crises.


Asunto(s)
COVID-19 , Desfibriladores Implantables , Marcapaso Artificial , Adolescente , COVID-19/epidemiología , Niño , Femenino , Humanos , Pandemias , Estudios Retrospectivos
6.
Pacing Clin Electrophysiol ; 44(4): 586-594, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33432629

RESUMEN

BACKGROUND: Pediatric and congenital heart disease (CHD) patients have a high rate of transvenous (TV) lead failure. OBJECTIVE: To determine whether TV lead age can aid risk assessment for lead failure to guide the decision of whether a lead should be replaced or reused at the time of a generator change. METHODS: Retrospective cohort study of patients <21 years old undergoing TV device implant from 2000 to 2014 at our institution. Patient, device, and lead variables were collected. Leads were compared in groups based on how many generator changes were completed. RESULTS: A total of 393 leads in 257 patients met inclusion criteria, 60 leads failed (15%). Failed leads were more likely to have not yet undergone generator change (p = .048). CHD (p = .045), Tendril lead type (p = .02) and silicone insulation (p = .02) were associated with failure. In multivariate analysis, younger leads (p = .022), number of generator changes (p = .003), CHD (p = .005) and silicone insulation (p = .004) remained significant while Tendril lead type did not (p = .052). Survival curves show an early decline around 4 years. CONCLUSIONS: Lead failure rate in pediatric and CHD patients is high. Leads that have not yet undergone a generator change were more likely to fail in this cohort. The strategy of serial replacement based on lead age needs further research to justify in this population.


Asunto(s)
Electrodos Implantados/efectos adversos , Análisis de Falla de Equipo , Cardiopatías Congénitas/terapia , Procedimientos Quirúrgicos Cardíacos , Niño , Desfibriladores Implantables , Remoción de Dispositivos , Femenino , Humanos , Masculino , Marcapaso Artificial , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Adulto Joven
7.
Cardiol Young ; : 1-6, 2021 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-34709150

RESUMEN

INTRODUCTION: Reflex-mediated syncope occurs in 15% of children and young adults. In rare instances, pacemakers are required to treat syncopal episodes associated with transient sinus pauses or atrioventricular block. This study describes a single centre experience in the use of permanent pacemakers to treat syncope in children and young adults. MATERIALS AND METHODS: Patients with significant pre-syncope or syncope and pacemaker implantation from 1978 to 2018 were reviewed. Data collected included the age of presentation, method of diagnosis, underlying rhythm disturbance, age at implant, type of pacemaker implanted, procedural complications and subsequent symptoms. RESULTS: Fifty patients were identified. Median age at time of the first syncopal episode was 10.2 (range 0.3-20.4) years, with a median implant age of 14.9 (0.9-34.3) years. Significant sinus bradycardia/pauses were the predominant reason for pacemaker implant (54%), followed by high-grade atrioventricular block (30%). Four (8%) patients had both sinus pauses and atrioventricular block documented. The majority of patients had dual-chamber pacemakers implanted (58%), followed by ventricular pacemakers (38%). Median follow-up was 6.7 (0.4-33.0) years. Post-implant, 4 (8%) patients continued to have syncope, 7 (14%) had complete resolution of their symptoms, and the remaining reported a decrease in their pre-syncopal episodes and no further syncope. Twelve (24%) patients had complications, including two infections and eight lead malfunctions. CONCLUSIONS: Paediatric patients with reflex-mediated syncope can be treated with pacing. Complication rates are high (24%); as such, permanent pacemakers should be reserved only for those in whom asystole from sinus pauses or atrioventricular block has been well documented.

8.
Cardiol Young ; 31(11): 1738-1769, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34338183

RESUMEN

In view of the increasing complexity of both cardiovascular implantable electronic devices (CIEDs) and patients in the current era, practice guidelines, by necessity, have become increasingly specific. This document is an expert consensus statement that has been developed to update and further delineate indications and management of CIEDs in pediatric patients, defined as ≤21 years of age, and is intended to focus primarily on the indications for CIEDs in the setting of specific disease categories. The document also highlights variations between previously published adult and pediatric CIED recommendations and provides rationale for underlying important differences. The document addresses some of the deterrents to CIED access in low- and middle-income countries and strategies to circumvent them. The document sections were divided up and drafted by the writing committee members according to their expertise. The recommendations represent the consensus opinion of the entire writing committee, graded by class of recommendation and level of evidence. Several questions addressed in this document either do not lend themselves to clinical trials or are rare disease entities, and in these instances recommendations are based on consensus expert opinion. Furthermore, specific recommendations, even when supported by substantial data, do not replace the need for clinical judgment and patient-specific decision-making. The recommendations were opened for public comment to Pediatric and Congenital Electrophysiology Society (PACES) members and underwent external review by the scientific and clinical document committee of the Heart Rhythm Society (HRS), the science advisory and coordinating committee of the American Heart Association (AHA), the American College of Cardiology (ACC), and the Association for European Paediatric and Congenital Cardiology (AEPC). The document received endorsement by all the collaborators and the Asia Pacific Heart Rhythm Society (APHRS), the Indian Heart Rhythm Society (IHRS), and the Latin American Heart Rhythm Society (LAHRS). This document is expected to provide support for clinicians and patients to allow for appropriate CIED use, appropriate CIED management, and appropriate CIED follow-up in pediatric patients.


Asunto(s)
Cardiología , Desfibriladores Implantables , American Heart Association , Electrofisiología Cardíaca , Niño , Consenso , Electrónica , Humanos , Estados Unidos
9.
Indian Pacing Electrophysiol J ; 21(6): 349-366, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34333142

RESUMEN

Guidelines for the implantation of cardiac implantable electronic devices (CIEDs) have evolved since publication of the initial ACC/AHA pacemaker guidelines in 1984 [1]. CIEDs have evolved to include novel forms of cardiac pacing, the development of implantable cardioverter defibrillators (ICDs) and the introduction of devices for long term monitoring of heart rhythm and other physiologic parameters. In view of the increasing complexity of both devices and patients, practice guidelines, by necessity, have become increasingly specific. In 2018, the ACC/AHA/HRS published Guidelines on the Evaluation and Management of Patients with Bradycardia and Cardiac Conduction Delay [2], which were specific recommendations for patients >18 years of age. This age-specific threshold was established in view of the differing indications for CIEDs in young patients as well as size-specific technology factors. Therefore, the following document was developed to update and further delineate indications for the use and management of CIEDs in pediatric patients, defined as ≤21 years of age, with recognition that there is often overlap in the care of patents between 18 and 21 years of age. This document is an abbreviated expert consensus statement (ECS) intended to focus primarily on the indications for CIEDs in the setting of specific disease/diagnostic categories. This document will also provide guidance regarding the management of lead systems and follow-up evaluation for pediatric patients with CIEDs. The recommendations are presented in an abbreviated modular format, with each section including the complete table of recommendations along with a brief synopsis of supportive text and select references to provide some context for the recommendations. This document is not intended to provide an exhaustive discussion of the basis for each of the recommendations, which are further addressed in the comprehensive PACES-CIED document [3], with further data easily accessible in electronic searches or textbooks.

10.
Indian Pacing Electrophysiol J ; 21(6): 367-393, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34333141

RESUMEN

In view of the increasing complexity of both cardiovascular implantable electronic devices (CIEDs) and patients in the current era, practice guidelines, by necessity, have become increasingly specific. This document is an expert consensus statement that has been developed to update and further delineate indications and management of CIEDs in pediatric patients, defined as ≤21 years of age, and is intended to focus primarily on the indications for CIEDs in the setting of specific disease categories. The document also highlights variations between previously published adult and pediatric CIED recommendations and provides rationale for underlying important differences. The document addresses some of the deterrents to CIED access in low- and middle-income countries and strategies to circumvent them. The document sections were divided up and drafted by the writing committee members according to their expertise. The recommendations represent the consensus opinion of the entire writing committee, graded by class of recommendation and level of evidence. Several questions addressed in this document either do not lend themselves to clinical trials or are rare disease entities, and in these instances recommendations are based on consensus expert opinion. Furthermore, specific recommendations, even when supported by substantial data, do not replace the need for clinical judgment and patient-specific decision-making. The recommendations were opened for public comment to Pediatric and Congenital Electrophysiology Society (PACES) members and underwent external review by the scientific and clinical document committee of the Heart Rhythm Society (HRS), the science advisory and coordinating committee of the American Heart Association (AHA), the American College of Cardiology (ACC), and the Association for European Paediatric and Congenital Cardiology (AEPC). The document received endorsement by all the collaborators and the Asia Pacific Heart Rhythm Society (APHRS), the Indian Heart Rhythm Society (IHRS), and the Latin American Heart Rhythm Society (LAHRS). This document is expected to provide support for clinicians and patients to allow for appropriate CIED use, appropriate CIED management, and appropriate CIED follow-up in pediatric patients.

11.
Am Heart J ; 230: 82-92, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33017579

RESUMEN

Past studies have not detected consistent improvement in ventricular function (VFxn) following initiation of cardiac resynchronization therapy (CRT) in Fontan patients. However, these studies used qualitative assessments of VFxn and/or quantitative assessments of VFxn that rely upon anatomic and/or geometric assumptions that may not be valid in patients with single ventricles. To address this, we used quantitative indices of global VFxn (dP/dtic and the Tei index) that are not encumbered by the limitations associated with the indices used in previous studies of CRT in Fontan patients. METHODS: Patients with Fontan physiology who had received CRT therapy from 2004 to 2019 were included in the study. They were compared to a concurrent group of Fontan patients who had received standard dual-chamber pacemakers (DCPMs). RESULTS: VFxn was assessed at 3 time points: prior to, shortly after, and late after initiation of pacemaker therapy. Prior to initiation of pacemaker therapy, VFxn of the CRT patients tended to be worse than that of the DCPM patients. For both groups, VFxn appeared to be stable or slightly improved shortly after initiation of pacemaker therapy. In the CRT group, VFxn improved significantly between early and late follow-up. In contrast, VFxn in DCPM patients tended to decline during this period. Changes in VFxn correlated with concurrent changes in New York Heart Association classification. CONCLUSIONS: Quantitative assessments of VFxn using indices not confounded by complex cardiac anatomy, segmental wall motions abnormalities, or inappropriate geometric assumptions revealed that CRT in Fontan patients is associated with preservation or improvement VFxn compared to standard DCPM. Changes in VFxn correlate with concurrent changes in New York Heart Association classification.


Asunto(s)
Terapia de Resincronización Cardíaca , Procedimiento de Fontan , Marcapaso Artificial , Función Ventricular/fisiología , Adolescente , Niño , Ecocardiografía/métodos , Femenino , Procedimiento de Fontan/efectos adversos , Humanos , Masculino , Estudios Retrospectivos , Estadísticas no Paramétricas , Factores de Tiempo
12.
J Cardiovasc Electrophysiol ; 31(12): 3243-3250, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33112018

RESUMEN

INTRODUCTION: Guidelines recommend trans-esophageal echocardiography (TEE) for patients with atrial fibrillation (AF) or atrial flutter (AFL) for >48 h, due to risk of intracardiac thrombus formation. With growing evidence that AFL in adults with structurally normal hearts has less thrombogenic potential compared to AF, and the need for TEE questioned, we compared prevalence of intracardiac thrombus detected by TEE in pediatric and congenital heart disease (CHD) patients presenting in AF and AFL. METHODS/RESULTS: Single-center, cross-sectional analysis for unique first-time presentations of patients for either AF, AFL, or intra-atrial reentrant tachycardia (IART) between 2000 and 2019. Patients were categorized by presenting arrhythmia (AF vs. AFL/IART), with the exclusion of other forms of atrial tachycardia, hemodynamic instability, chronic anti-coagulation before TEE, and presentation for a reason other than TEE examination for thrombus. A total of 201 patients had TEE with co-diagnosis of AF or AFL. Of these, 105 patients (29 AF, 76 AFL) met inclusion criteria, with no difference in age between AF (median 24.9 years; IQR 18.6-38.3 years) and AFL/IART (23.3 years; 15.4-38.4 years). The prevalence of thrombus in the entire cohort was 9.5%, with no difference between AF (13.8%) and AFL groups (7.9%), p = .46. Patients with thrombus demonstrated no difference in age, systemic ventricular function, cardiac complexity, or CHADS2/CHA2DS2VASc score at presentation. CONCLUSIONS: The risk for intracardiac thrombus is high in the pediatric and CHD population, with no apparent distinguishing factors to warrant a change in the recommendations for TEE, with all levels of cardiac complexity being at risk for clot.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Cardiopatías Congénitas , Trombosis , Adolescente , Adulto , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/epidemiología , Aleteo Atrial/diagnóstico por imagen , Aleteo Atrial/epidemiología , Niño , Estudios Transversales , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/epidemiología , Humanos , Prevalencia , Trombosis/diagnóstico por imagen , Trombosis/epidemiología , Adulto Joven
13.
J Cardiovasc Electrophysiol ; 31(5): 1105-1113, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32100356

RESUMEN

OBJECTIVES: To describe a single institutional experience managing fetuses with supraventricular tachycardia (SVT) and to identify associations between patient characteristics and fetal and postnatal outcomes. BACKGROUND: Sustained fetal SVT is associated with significant morbidity and mortality if untreated, yet the optimal management strategy remains unclear. METHODS: Retrospective cohort study including fetuses diagnosed with sustained SVT (>50% of the diagnostic echocardiogram) between 1985 and 2018. Fetuses with congenital heart disease were excluded. RESULTS: Sustained SVT was diagnosed in 65 fetuses at a median gestational age of 30 weeks (range, 14-37). Atrioventricular re-entrant tachycardia and atrial flutter were the most common diagnoses, seen in 41 and 16 cases, respectively. Moderate/severe ventricular dysfunction was present in 20 fetuses, and hydrops fetalis was present in 13. Of the 57 fetuses initiated on transplacental drug therapy, 47 received digoxin first-line, yet 39 of 57 (68%) required advanced therapy with sotalol, flecainide, or amiodarone. Rate or rhythm control was achieved in 47 of 57 treated fetuses. There were no cases of intrauterine fetal demise. Later gestational age at fetal diagnosis (odds ratio [OR], 1.1, 95% confidence interval [CI], 1.01-1.2, P = .02) and moderate/severe fetal ventricular dysfunction (OR, 6.1, 95% CI, 1.7-21.6, P = .005) were associated with postnatal SVT. Two postnatal deaths occurred. CONCLUSIONS: Fetuses with structurally normal hearts and sustained SVT can be effectively managed with transplacental drug therapy with minimal risk of intrauterine fetal demise. Treatment requires multiple antiarrhythmic agents in over half of cases. Later gestational age at fetal diagnosis and the presence of depressed fetal ventricular function, but not hydrops, predict postnatal arrhythmia burden.


Asunto(s)
Antiarrítmicos/uso terapéutico , Enfermedades Fetales/tratamiento farmacológico , Corazón Fetal/efectos de los fármacos , Frecuencia Cardíaca Fetal/efectos de los fármacos , Taquicardia Supraventricular/tratamiento farmacológico , Adolescente , Adulto , Antiarrítmicos/efectos adversos , Ecocardiografía , Electrocardiografía , Femenino , Muerte Fetal , Enfermedades Fetales/diagnóstico , Enfermedades Fetales/mortalidad , Enfermedades Fetales/fisiopatología , Corazón Fetal/diagnóstico por imagen , Corazón Fetal/fisiopatología , Edad Gestacional , Humanos , Recién Nacido , Masculino , Intercambio Materno-Fetal , Embarazo , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/mortalidad , Taquicardia Supraventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Prenatal , Adulto Joven
14.
Pacing Clin Electrophysiol ; 43(9): 901-907, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32329521

RESUMEN

OBJECTIVE: To determine the impact of provocative electrophysiology testing in postoperative congenital heart disease (CHD) patients on the management of supraventricular tachycardia (SVT) and clinical outcomes. METHODS: This is a retrospective study including patients <18 years of age with surgery for CHD who had postoperative SVT between 2006 and 2017. Postoperative outcomes were compared between patients with and without postoperative electrophysiology testing using the Wilcoxon rank sum test, Fisher's exact test, Kaplan-Meier method with the log-rank test, and Cox proportional hazard model. RESULTS: From 341 patients who had SVT after surgery for CHD, 65 (19%) had postoperative electrophysiology testing. There was no significant difference in baseline patient characteristics or surgical complexity between patients with and without electrophysiology testing. Patients with inducible SVT on electrophysiology testing were more likely to have recurrence of SVT prior to hospital discharge with an odds ratio 4.0 (95% confidence interval 1.3, 12.0). Patients who underwent postoperative electrophysiology testing had shorter intensive care unit (12 [6, 20] vs 16 [9, 32] days, HR 2.1 [95% CI 1.6, 2.8], P < .001) and hospital (25 [13, 38] vs 31 [18, 54] days, HR 1.8 [95% CI 1.4, 2.4], P < .001) length of stay. CONCLUSION: Postoperative electrophysiology testing was associated with improved postoperative outcomes, likely related to the ability to predict recurrence of arrhythmia and tailored antiarrhythmic management.


Asunto(s)
Técnicas Electrofisiológicas Cardíacas/métodos , Taquicardia Supraventricular/fisiopatología , Taquicardia Supraventricular/cirugía , Preescolar , Electrocardiografía , Femenino , Humanos , Lactante , Recién Nacido , Tiempo de Internación/estadística & datos numéricos , Masculino , Cuidados Posoperatorios , Estudios Retrospectivos , Taquicardia Supraventricular/congénito , Telemetría
15.
J Cardiovasc Electrophysiol ; 30(3): 320-325, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30556201

RESUMEN

BACKGROUND: Implantable cardioverter defibrillator (ICD) lead failures occur at higher rates in pediatric and congenital heart disease (CHD) patients. OBJECTIVE: To determine the rate and timing of Riata lead failure in pediatric and CHD patients. METHODS: This was a retrospective, multicenter cohort study of pediatric patients and adults with CHD with implantation of a Riata or Riata ST lead between 2002 and 2009. The prevalence and timing of electrical failure and conductor coil externalization (CCE) were determined. RESULTS: Fifty-eight patients and 63 leads from seven centers were included. Median (interquartile range [IQR]) age at implant was 14.4 (11.5-18.7) years and median follow-up was 8.7 (7.3-11.1) years. The underlying diagnosis was a primary arrhythmia disorder in 45%, cardiomyopathy in 31%, and CHD in 28% of patients. Electrical failure occurred in 43% and CCE in 16% of leads at median lead ages of 4.7 (3.4-7.5) and 4.3 (3.9-7.0) years, respectively. Median lead survival free from electrical failure or CCE was 7.9 (95% confidence interval, 5.8-10.0) years. Forty-one percent of leads were functional at the end of the follow-up period, and 33% were extracted with a complication rate of 5%. CONCLUSIONS: The rate of Riata lead electrical failure was high in children and patients with CHD, while the rate of CCE was comparable with published data. Counseling on lead management should factor in the high rate of electrical failure with considerations for elective replacement.


Asunto(s)
Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Cardiopatías Congénitas/terapia , Falla de Prótesis , Adolescente , Factores de Edad , Canadá , Niño , Preescolar , República Checa , Remoción de Dispositivos , Cardioversión Eléctrica/efectos adversos , Femenino , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/fisiopatología , Humanos , Masculino , Supervivencia sin Progresión , Diseño de Prótesis , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Estados Unidos
16.
J Cardiothorac Vasc Anesth ; 33(7): 1932-1938, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30902553

RESUMEN

OBJECTIVE: The utility of extracorporeal membrane oxygenation (ECMO) as an elective support modality for high-risk cardiac procedures is extensively described in adults, but its use in children is limited to isolated reports. The objective of this study was to analyze the outcomes of patients who underwent elective cannulation to ECMO for this purpose. DESIGN: Single-center, retrospective chart review. SETTING: Free-standing pediatric tertiary care center. PARTICIPANTS: Patients who underwent elective cannulation to ECMO for cardiorespiratory support during a high-risk cardiac catheterization procedure. INTERVENTIONS: Elective ECMO cannulation for high-risk percutaneous cardiac interventions or electrophysiology procedures. MEASUREMENTS AND MAIN RESULTS: Survival to discharge was 71.4% compared with 30% for patients who required extracorporeal cardiopulmonary resuscitation in the cardiac catheterization laboratory. The mean duration of cannulation was 137.43 hours (range 27-615 h, median 55 h). There were no major neurologic sequelae, but ECMO circuit thrombosis (57%) was relatively common. CONCLUSION: The use of elective ECMO support for high-risk pediatric cardiac catheterizations can be accomplished safely and may allow for an improved rate of survival with lower rates of severe adverse events compared with extracorporeal cardiopulmonary resuscitation as rescue therapy.


Asunto(s)
Cateterismo Cardíaco/métodos , Oxigenación por Membrana Extracorpórea/métodos , Adulto , Preescolar , Oxigenación por Membrana Extracorpórea/efectos adversos , Femenino , Humanos , Lactante , Masculino , Estudios Retrospectivos
18.
Pacing Clin Electrophysiol ; 41(9): 1143-1149, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29989175

RESUMEN

BACKGROUND: Left ventricular false tendons (FT) traverse the ventricular cavity and are thought to have some association with idiopathic left ventricular tachycardia (ILVT). However, reported prevalence of FT varies widely, making correlation difficult. Superior echocardiographic windows of pediatric patients may permit better analysis of FT in ILVT. Our study describes the relationship between FT and ILVT in young patients. METHODS: Retrospective case-control study of 30 ILVT patients with 98 controls compared for FT. Diagnosis of ILVT was made by electrocardiogram and clinical history, and for 25 patients was further confirmed by electrophysiology study (EPS). Presence of FT was identified by one blinded observer and verified by a second blinded observer. Presence of FT was then compared between ILVT patients and controls using Fisher's exact test. RESULTS: Presence of FT did not differ significantly between patients and controls (53% vs 43%, P  =  0.40). Twelve FT patients (19%) had multiple FTs detected, though the incidence of ILVT was no higher in the setting of multiple FTs. A total of 25 patients with ILVT underwent EPS for intended ablation therapy, with ultimate success in 22/25 (88%) after one or more ablation sessions. Of the 25 EPS patients, FTs were present in 11, but precise correlation between successful ablation location and FT location was not possible since intraprocedural echocardiography was not performed in this patient group. CONCLUSIONS: Presence of FTs did not differ between ILVT patients and controls. While FTs are not absolutely required for ILVT, they may still play a role in some cases.


Asunto(s)
Taquicardia Ventricular/fisiopatología , Tendones/anomalías , Tendones/fisiopatología , Adolescente , Estudios de Casos y Controles , Niño , Preescolar , Ecocardiografía , Electrocardiografía , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Estudios Retrospectivos , Taquicardia Ventricular/diagnóstico por imagen , Tendones/diagnóstico por imagen , Adulto Joven
20.
Europace ; 16(2): 277-83, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23928735

RESUMEN

AIMS: Non-fluoroscopic imaging (NFI) devices are increasingly used in ablations. The objective was to determine the utility of intracardiac echocardiography (ICE) in ablating paediatric supraventricular tachycardias (SVTs) and assess whether its integrated use with electroanatomic mapping (EAM) resulted in lower radiation exposure than use of EAM alone. METHODS AND RESULTS: Prospective, controlled, single-centre study of patients (pts) age ≥10 years, weight ≥35 kg, with SVT and normal cardiac anatomy. Patients were randomized to ICE + EAM (ICE) or EAM only (no ICE). Both had access to fluoroscopy as needed. Eighty-four pts were enroled (42 ICE, 42 no ICE). Median age was 15 years (range 10.4-23.7 years); 57% had accessory pathways, 42% atrioventricular nodal reentry tachycardia. There was no difference in radiation dose (9 mGy ICE vs. 23 mGy no ICE, P = 0.37) or fluoroscopy time (1.1 min ICE vs. 1.5 min no ICE, P = 0.38). Transseptal punctures were performed in 25 pts (16 ICE, 9 no ICE), with ICE reducing radiation (8 mGy ICE vs. 62 mGy no ICE, P = 0.002) and fluoroscopy time (1.1 min ICE vs. 4.5 min no ICE, P = 0.01). Zero fluoroscopy was achieved in 13 pts (15% of total, 5 ICE, 8 no ICE), and low-dose cases (<50 mGy) in 57 pts (68% of total, 33 ICE, 24 no ICE). Acute success was 95% for ICE, 88% for no ICE. CONCLUSION: Use of an integrated EAM/ICE system was no better than EAM alone in limiting radiation, but can be helpful for transseptal punctures. Given the low dose savings, use of ICE may be weighed against its financial cost. Low-fluoroscopy cases are performed in most NFI procedures.


Asunto(s)
Ablación por Catéter , Ecocardiografía , Técnicas Electrofisiológicas Cardíacas , Dosis de Radiación , Radiografía Intervencional , Cirugía Asistida por Computador , Taquicardia Supraventricular/cirugía , Adolescente , Factores de Edad , Boston , Ablación por Catéter/efectos adversos , Niño , Femenino , Fluoroscopía , Humanos , Masculino , Valor Predictivo de las Pruebas , Estudios Prospectivos , Punciones , Radiografía Intervencional/efectos adversos , Cirugía Asistida por Computador/efectos adversos , Taquicardia Supraventricular/diagnóstico por imagen , Taquicardia Supraventricular/fisiopatología , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA