Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Water Sci Technol ; 88(7): 1833-1846, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37830999

RESUMEN

Illicit connections of wastewater to stormwater systems are the main drawback of separate sewer systems, as they lead to a direct discharge of untreated wastewater to the aquatic environment. Consequently, several inspection methods have been developed for detecting illicit connections. This study simultaneously applied several low- and high-tech methods for the detection of illicit connections in the same catchment (De Heuvel, the Netherlands). The methods included mesh wire screens for capturing coarse contamination, measurements of electroconductivity and temperature, sampling and quantification of Escherichia coli and extended-spectrum ß-lactamase-producing E. coli (ESBL-EC), DNA analysis via quantitative polymerase chain reaction for human-, dog-, and bird-specific fecal indicators, and distributed temperature sensing. Significant illicit connections could be identified using all methods. Nonetheless, hydraulic conditions and, predominantly, the sewage volume determine whether a misconnection can be detected by especially the low-tech methods. Using these results, the identified misconnections were repaired and biological and DNA analyses were repeated. Our results demonstrate that there were no changes in E. coli or ESBL-EC before and after mitigation, suggesting that these common markers of fecal contamination are not specific enough to evaluate the performance of mitigation efforts. However, a marked decrease in human wastewater markers (HF183) was observed.


Asunto(s)
Monitoreo del Ambiente , Aguas Residuales , Animales , Humanos , Perros , Monitoreo del Ambiente/métodos , Escherichia coli/genética , Aguas del Alcantarillado/análisis , Heces/química , ADN
2.
Water Res ; 235: 119883, 2023 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-36989804

RESUMEN

The ecological state of receiving water bodies can be significantly influenced by organic micropollutants that are emitted via stormwater runoff. Reported efforts to quantify the emission of micropollutants mainly focus on sampling at combined sewer overflows and storm sewer outfalls, which can be challenging. An alternative method, called fingerprinting, was developed and tested in this study. The fingerprinting method utilizes wastewater treatment plant (WWTP) influent samples and derives the proportion of stormwater in a sample. This is achieved by comparing the wet weather vs dry weather concentrations of substances-tracers which are present only in wastewater. It is then possible to estimate the concentration of organic micropollutants in stormwater runoff from measurements in the influent of a WWTP based on a mass balance. In this research, the fingerprinting method was applied in influent samples obtained in five WWTPs in the Netherlands. In total, 28 DWF and 22 WWF samples were used. The chosen tracers were ibuprofen, 2-hydroxyibuprofen, naproxen and diclofenac. Subsequently, the concentration in stormwater runoff of 403 organic micropollutants was estimated via the WWF samples. The substances that were present and analyzed included glyphosate and AMPA, 24 out of 254 pesticides, 6 out of 28 organochlorine pesticides, 45 out of 63 pharmaceuticals, 15 out of 15 PAHs, 2 of the 7 PCBs, and 20 of 33 other substances (e.g. bisphenol-A). A comparison with findings from other studies suggested that the fingerprinting method yields trustworthy results. It was also noted that a representative and stable dry weather flow reference concentration is a strict requirement for the successful application of the proposed method.


Asunto(s)
Plaguicidas , Contaminantes Químicos del Agua , Aguas del Alcantarillado , Contaminantes Químicos del Agua/análisis , Monitoreo del Ambiente , Aguas Residuales , Plaguicidas/análisis
3.
Water Res ; 122: 678-691, 2017 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-28683404

RESUMEN

Separate sewer systems are sensitive to illegal or mis-connections. Several techniques (including the Distributed Temperature Sensor) are now available to identify and locate those connections. Based on thermal fingerprints, DTS allows the localization of each lateral connection along a reach. The use of Infra-Red camera has been investigated with 748 laboratory experiments (artificial connections along a flume). The tested connections vary in diameters (from 75 to 200 mm), lengths of intrusion (from 0 to 200 m), shapes (circular or linear i.e. cracks), depths, discharge rates between the lateral connection and the main flume, and temperatures. IR frame analysis (for detection) and 2D temperature mapping (at the free water surface, for quantification) demonstrate that: i) the detection limit is very low (ratio between lateral and main discharges: 0.025) and ii) the quantification of the lateral discharge is impossible. Application of an IR camera seems to be a promising technique to detect lateral connections.


Asunto(s)
Aguas del Alcantarillado , Diseño de Equipo , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA