Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Ophthalmic Physiol Opt ; 44(4): 774-786, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38578134

RESUMEN

PURPOSE: To investigate gaze and behavioural metrics at different viewing distances with multifocal contact lenses (MFCLs), single vision contact lenses (SVCLs) and progressive addition lenses (PALs). METHODS: Fifteen presbyopic contact lens wearers participated over five separate study visits. At each visit, participants were randomly assigned to wear one of five refractive corrections: habitual PAL spectacles, delefilcon A (Alcon Inc.) MFCLs and three separate pairs of delefilcon A single vision lenses worn as distance, intermediate and near corrections. Participants wore a Pupil Core headset to record eye and head movements while performing three visual tasks: reading, visual search and scene observation. Data were investigated using linear regression and post-hoc testing. Parameters of interest included gaze (fixation duration, head movement) and behavioural (reading speed, reading accuracy, visual search time) metrics. RESULTS: Reading speed in SVCLs was significantly faster than in MFCLs and PAL spectacles (F = 16.3, p < 0.0001). Refractive correction worn did not influence visual search times (F = 0.16, p = 0.85). Fixation duration was significantly affected by the type of visual task (F = 60.2, p < 0.001), and an interaction effect was observed between viewing distance and refractive correction (F = 4.3, p = 0.002). There was significantly more horizontal and vertical head movement (F = 3.2, p = 0.01 and F = 3.3, p = 0.01, respectively) during visual search tasks when wearing PAL spectacles compared to SVCLs or MFCLs. CONCLUSION: This work showed that the type of refractive correction affects behavioural metrics such as reading speed and gaze behaviour by affecting horizontal and vertical head movements. The findings of this study suggest that under certain conditions, wearers of MFCLs make fewer head movements compared to PAL spectacles. Gaze behaviour metrics offer a new approach to compare and understand contact lens and spectacle performance, with potential applications including peripheral optical designs for myopia management.


Asunto(s)
Lentes de Contacto , Anteojos , Fijación Ocular , Presbiopía , Lectura , Refracción Ocular , Agudeza Visual , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Movimientos Oculares/fisiología , Fijación Ocular/fisiología , Movimientos de la Cabeza/fisiología , Presbiopía/fisiopatología , Presbiopía/terapia , Refracción Ocular/fisiología , Agudeza Visual/fisiología , Estudios Cruzados , Estudios Prospectivos
2.
Ophthalmic Physiol Opt ; 44(5): 894-909, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38708449

RESUMEN

PURPOSE: To investigate whether there is a measurable change in meibomian gland morphological characteristics over the course of a day (12 h) and over a month. METHODS: The study enrolled 15 participants who attended a total of 11 study visits spanning a 5-week period. To assess diurnal changes in meibomian glands, seven visits were conducted on a single day, each 2 h apart. For monthly assessment, participants attended an additional visit at the same time of the day every week for three consecutive weeks. Meibography using the LipiView® II system was performed at each visit, and meibomian gland morphological parameters were calculated using custom semi-automated software. Specifically, six central glands were analysed for gland length ratio, gland width, gland area, gland intensity and gland tortuosity. RESULTS: The average meibomian gland morphological metrics did not exhibit significant changes during the course of a day or over a month. Nonetheless, certain individual gland metrics demonstrated notable variation over time, both diurnally and monthly. Specifically, meibomian gland length ratio, area, width and tortuosity exhibited significant changes both diurnally and monthly when assessed on a gland-by-gland basis. CONCLUSIONS: Meibomian glands demonstrated measurable structural change over short periods of time (hours and days). These results have implications for innovation in gland imaging and for developing precision monitoring of gland structure to assess meibomian gland health more accurately.


Asunto(s)
Glándulas Tarsales , Humanos , Glándulas Tarsales/diagnóstico por imagen , Glándulas Tarsales/anatomía & histología , Proyectos Piloto , Femenino , Masculino , Persona de Mediana Edad , Adulto , Anciano , Disfunción de la Glándula de Meibomio/diagnóstico , Disfunción de la Glándula de Meibomio/diagnóstico por imagen , Lágrimas/fisiología , Ritmo Circadiano/fisiología , Factores de Tiempo
3.
Ophthalmic Physiol Opt ; 44(4): 704-717, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38546401

RESUMEN

PURPOSE: To investigate differences in key clinical parameters between asymptomatic and highly symptomatic soft contact lens (CL) wearers after 14 h of wear. METHODS: In this pilot investigation, Phase 1 identified asymptomatic (CLDEQ-8 score ≤ 7) and highly symptomatic (CLDEQ-8 score ≥ 20) subjects after fitting with nelfilcon A CLs. Phase 2 investigated the following over a single nelfilcon A CL-wearing day (14 ± 2 h): blinking characteristics, tear meniscus height (TMH), non-invasive tear break-up time (NIBUT), tear film osmolarity and eyelid margin staining. Parameters for the two groups were compared using linear mixed models and post-hoc testing. The relationship between comfort scores and the clinical parameters was also investigated. RESULTS: Overall, 161 and 42 subjects were enrolled into Phase 1 and 2, respectively. Twenty-five asymptomatic and 17 symptomatic subjects completed Phase 2. Lower eyelid TMH was decreased after 14 h in symptomatic compared with asymptomatic subjects (least square mean [LSM] difference -0.04 mm, 95% CI: -0.07, -0.01). Osmolarity was lower in symptomatic than in asymptomatic subjects at fitting (LSM difference -9.89, 95% CI: -18.91, -0.86). Upper eyelid margin staining was greater after 14 h in symptomatic than in asymptomatic subjects (LSM difference 0.53, 95% CI: 0.01, 1.05) and greater after 14 h than baseline in the symptomatic group (LSM difference 0.61, 95% CI: 0.16, 1.07). There was a significant relationship between comfort and upper eyelid margin staining (r = -0.40, 95% CI: -0.63, -0.11) and blink rate (r = -0.31, 95% CI: -0.57, -0.003). CONCLUSION: The potential parameters most effective in differentiating asymptomatic from symptomatic wearers were upper eyelid margin staining and lower TMH. The parameter with the strongest relationship to comfort was upper eyelid margin staining, where higher comfort scores were associated with lower levels of staining.


Asunto(s)
Parpadeo , Lentes de Contacto Hidrofílicos , Lágrimas , Humanos , Lentes de Contacto Hidrofílicos/efectos adversos , Masculino , Femenino , Adulto , Lágrimas/metabolismo , Lágrimas/fisiología , Proyectos Piloto , Parpadeo/fisiología , Adulto Joven , Concentración Osmolar , Síndromes de Ojo Seco/diagnóstico , Síndromes de Ojo Seco/etiología , Síndromes de Ojo Seco/fisiopatología , Párpados
4.
Int J Mol Sci ; 23(17)2022 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-36077001

RESUMEN

Meibomian gland orifices (MGOs) are located along the eyelid margin and secrete meibum into the tear film. The profile of resident innate immune cells (ICs) at this site is not well understood. The distribution and phenotype of resident ICs around MGOs in mice was investigated and herein defined as MGO-associated immune cells (MOICs). The effect of topical 0.1% benzalkonium chloride (BAK) on MOICs was also assessed. Eyelids from healthy CD11ceYFP and Cx3cr1gfp/gfp mice aged three or seven months were compared. ICs were identified as CD11c+, Cx3cr1+, and MHC-II+ using four-colour immunostaining and confocal microscopy. MOIC density was variable but clustered around MGOs. There were more CD11c+ MOICs in three-month-old compared with seven-month-old mice (three-month-old: 893 ± 449 cells/mm2 vs. seven-month-old: 593 ± 493 cells/mm2, p = 0.004). Along the eyelid margin, there was a decreasing gradient of CD11c+ MOIC density in three-month-old mice (nasal: 1003 ± 369 cells/mm2, vs. central: 946 ± 574 cells/mm2, vs. temporal: 731 ± 353 cells/mm2, p = 0.044). Cx3cr1-deficient mice had two-fold fewer MHC-II+ MOICs, suggesting a role for Cx3cr1 receptor signaling in meibomian gland surveillance. CD11c+ MOIC density was lower in BAK-exposed eyes compared to saline-treated controls, suggesting a change in homeostasis. This study provides novel insight into resident ICs located at MGOs, and their contribution to MG homeostasis.


Asunto(s)
Enfermedades de los Párpados , Glándulas Tarsales , Animales , Compuestos de Benzalconio/farmacología , Ratones , Fenotipo , Lágrimas
5.
Ophthalmic Physiol Opt ; 40(4): 519-528, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32452570

RESUMEN

PURPOSE: Development and validation of a non-invasive imaging system to capture spontaneous blinking and characterise blink dynamics using a custom image analysis algorithm. METHODS: A pilot study investigated the influence of illumination type on blink dynamics. Spontaneous blinking was recorded in eight subjects using a high-speed camera under two illumination conditions: white light and infrared. Custom semi-automated software assessed palpebral aperture height (PAH), blink rate, blink speed, blink completeness and blink duration. The main clinical study compared two different image analysis techniques. Spontaneous blinking was recorded in 20 subjects using a high-speed infrared camera. Blink speed and duration were determined using two techniques: manual tracking and semi-automated tracking. Agreement between the two techniques was assessed using Bland-Altman analysis. Coefficients of repeatability (COR) were calculated for the semi-automated technique. RESULTS: There were significant differences between white light and infrared illumination for PAH (p < 0.0001), blink rate (p = 0.04), closing speed (p = 0.009), opening speed (p < 0.0001) and blink duration (p = 0.0003). The mean differences (95% limits of agreement) between the two techniques were 0.6 mm s-1 (-15.9 to 17.0) closing speed, 1.5 mm s-1 (-6.8 to 9.8) opening speed, 2.4 ms (-6.8 to 11.5) closed phase duration and 5.0 ms (-19.4 to 29.3) total blink duration. COR values were 10.1 mm s-1 closing speed, 3.7 mm s-1 opening speed, 6.7 ms closed phase duration and 11.2 ms total blink duration. CONCLUSIONS: This study has shown that spontaneous blinking can be characterised using a non-invasive imaging system. The semi-automated analysis provides a rapid characterisation of blink dynamics, allowing its application in large-scale trials in a number of clinical areas.


Asunto(s)
Parpadeo/fisiología , Diagnóstico por Imagen/métodos , Párpados/fisiología , Procesamiento de Imagen Asistido por Computador/instrumentación , Programas Informáticos , Adulto , Femenino , Humanos , Masculino , Proyectos Piloto , Grabación en Video
7.
Optom Vis Sci ; 93(8): 809-19, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-27309523

RESUMEN

PURPOSE: To compare subjective comfort and ocular physiology with three multipurpose solutions (MPSs) to that of a peroxide-based system with three different soft contact lens materials. METHODS: Habitual soft contact lens wearers (n = 236) were enrolled at three sites and completed a washout period with no contact lens solution for ≥4 days. Subjects were randomly assigned to one of three lens types: etafilcon A, galyfilcon A, or senofilcon A. A new lens of the assigned type was worn for 10 to 14 days each while using one of four care solutions, in random order (A-polyaminopropyl biguanide + polyquaternium, B-POLYQUAD + Aldox, C-alexidine + polyquaternium-1, and D-hydrogen peroxide) with a washout period (≥4 days) between each solution. After each care solution, biomicroscopy was performed and subjective comfort was assessed using the Contact Lens User Experience (CLUE) questionnaire and other instruments including comfortable wear time (CWT). Linear mixed models were used for analysis. Comfort and biomicroscopy signs with each MPS were compared to that of the peroxide solution. RESULTS: Subjective CLUE Comfort score across all lens types with each MPS was not significantly different than with the peroxide solution (p = 0.98). There were no differences in CWT between each MPS and the peroxide solution for any lens type (range of differences: -0.8 to 0.8 h; all p ≥ 0.13). Six MPS/material combinations had no clinically meaningful change in corneal staining versus peroxide (<0.5 units); three combinations could increase staining by up to 0.57 units. Staining was

Asunto(s)
Soluciones para Lentes de Contacto , Lentes de Contacto Hidrofílicos , Fenómenos Fisiológicos Oculares , Comodidad del Paciente , Adolescente , Adulto , Anciano , Biguanidas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Polímeros , Propilaminas , Coloración y Etiquetado , Encuestas y Cuestionarios
8.
Eye Contact Lens ; 42(5): 289-94, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26709982

RESUMEN

OBJECTIVES: To measure various dimensions of the upper tarsal plate and the area of upper lid wiper staining. The repeatability of the method of measurement was investigated. METHODS: Thirty-five healthy non-contact lens wearers were enrolled. The following parameters were measured from digital images of the upper eyelid captured with a slitlamp camera: length, height, and total area of the tarsal plate and area of lid wiper staining (lissamine green). Measurements were performed in a randomized and masked fashion on two separate occasions by the same investigator using ImageJ (National Institutes of Health). Coefficients of repeatability (COR) were calculated. RESULTS: The dimensions (mean±SD) of the tarsal plate were 20.6±1.9 mm length, 7.9±0.8 mm height, and 103.3±18.8 mm total area. The area of lid wiper staining was 2.7±2.0 mm. No association was found between tarsal dimensions and lid wiper staining (all P>0.05). Image analysis COR values were 0.6 mm tarsal length, 0.1 mm tarsal height, 1.2 mm tarsal area, and 0.4 mm lid wiper staining. There was no significant difference between repeated measurements for any parameter (all P>0.05). Limits of agreement were narrow for all parameters, indicating good agreement between repeated measurements. CONCLUSIONS: This work has demonstrated that there is a wide range in the dimensions of the upper tarsal plate in an urban UK population. No association was found between the upper tarsal dimensions and lid wiper staining. ImageJ was shown to be a repeatable method to measure the dimensions of the upper tarsal plate and upper lid wiper staining.


Asunto(s)
Conjuntiva/anatomía & histología , Párpados/anatomía & histología , Adulto , Femenino , Humanos , Colorantes Verde de Lisamina/administración & dosificación , Masculino , Fotograbar/métodos , Reproducibilidad de los Resultados , Reino Unido , Población Urbana , Adulto Joven
9.
Optom Vis Sci ; 92(1): 44-52, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25562479

RESUMEN

PURPOSE: To compare clinical and subjective quality-of-life (QoL) data for teenagers wearing daily disposable contact lenses or spectacles. METHODS: This open-label study randomized subjects (aged 13 to 19 years) with no previous contact lens wear experience to nelfilcon A (DAILIES AquaComfort Plus) contact lenses or spectacles for 6 months. A full clinical workup, as well as subjective QoL measures using the Pediatric Refractive Error Profile and Quality of Life Impact of Refractive Correction questionnaires, was conducted at baseline and at week 4 and months 3 and 6, with an additional study visit at week 2 for subjects randomized to wear contact lenses. RESULTS: A total of 110 teenagers were enrolled in the study; 13 discontinued before study completion, 10 (17.5%) from the contact lens group and 3 (5.7%) from the spectacle group (p = 0.04). Visual acuity was good for both groups at all study visits. Biomicroscopy assessments were similar at baseline for both groups. Significant differences in Pediatric Refractive Error Profile responses were noted between vision correction groups across visits for appearance (p < 0.001), satisfaction (p < 0.001), activities (p < 0.001), peer perception (p = 0.003), and overall score (p < 0.001). For Quality of Life Impact of Refractive Correction, the contact lens group gave more favorable responses than the spectacle group (p = 0.02). After 6 months of wearing contact lenses, teenagers had a more positive attitude toward comfort, vision, and safety with contact lenses. No serious adverse events were reported during the study. CONCLUSIONS: The daily disposable lenses used in this study are suitable for vision correction for teenagers, offering improvements in QoL measures during the first month of wear, including appearance, satisfaction, activities, and peer perceptions, without negatively impacting vision or eye health. Teenagers were able to handle contact lenses with the same amount of confidence as spectacles.


Asunto(s)
Lentes de Contacto Hidrofílicos , Anteojos , Miopía/psicología , Miopía/terapia , Calidad de Vida/psicología , Adolescente , Conducta del Adolescente/psicología , Equipos Desechables , Femenino , Humanos , Masculino , Miopía/fisiopatología , Satisfacción del Paciente , Ajuste de Prótesis , Autoimagen , Encuestas y Cuestionarios , Agudeza Visual/fisiología , Adulto Joven
10.
Transl Vis Sci Technol ; 12(2): 9, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36749580

RESUMEN

Purpose: To develop and evaluate a custom imaging system to provide high-resolution, wide depth-of-field, reflection-free, multispectral infrared (IR) imaging of the Meibomian glands. Methods: Lower eyelids of 15 volunteers were everted to obtain multispectral images of the Meibomian glands with custom imaging setup. Photographs were captured at 10 different ISO settings (from underexposure to overexposure) and using nine IR imaging filters (ranging from 600 nm to 1000 nm in 50-nm steps). Meibomian gland contrast (simple and Michelson) was calculated for the images to choose an optimal wavelength for Meibomian gland imaging and to determine differences in contrast across individuals. Results: The overall linear regression model showed a significant effect of wavelength on Meibomian gland contrast (Simple contrast: F = 7.24, P < 0.0001; Michelson contrast: F = 7.19, P < 0.0001). There was a significant negative correlation between Meibomian gland contrast and Meibomian gland depth for 750-nm IR filter (ρs= -0.579; P = 0.026). Conclusions: Meibomian gland contrast varies across individuals and depends on Meibomian gland depth. IR filter of 750 nm is the optimal choice for Meibomian gland imaging because it provides images of greatest contrast. Translational Relevance: This study adds to our understanding of Meibomian gland imaging. It has successfully demonstrated that Meibomian glands that are deeper in the tarsal plate require longer wavelengths for imaging.


Asunto(s)
Glándulas Tarsales , Humanos , Glándulas Tarsales/diagnóstico por imagen
11.
Ophthalmol Sci ; 3(4): 100334, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37920420

RESUMEN

Purpose: To develop and evaluate a deep learning algorithm for Meibomian gland characteristics calculation. Design: Evaluation of diagnostic technology. Subjects: A total of 1616 meibography images of both the upper (697) and lower (919) eyelids from a total of 282 individuals. Methods: Images were collected using the LipiView II device. All the provided data were split into 3 sets: the training, validation, and test sets. Data partitions used proportions of 70/10/20% and included data from 2 optometry settings. Each set was separately partitioned with these proportions, resulting in a balanced distribution of data from both settings. The images were divided based on patient identifiers, such that all images collected for one participant could end up only in one set. The labeled images were used to train a deep learning model, which was subsequently used for Meibomian gland segmentation. The model was then applied to calculate individual Meibomian gland metrics. Interreader agreement and agreement between manual and automated methods for Meibomian gland segmentation were also carried out to assess the accuracy of the automated approach. Main Outcome Measures: Meibomian gland metrics, including length ratio, area, tortuosity, intensity, and width, were measured. Additionally, the performance of the automated algorithms was evaluated using the aggregated Jaccard index. Results: The proposed semantic segmentation-based approach achieved average aggregated Jaccard index of mean 0.4718 (95% confidence interval [CI], 0.4680-0.4771) for the 'gland' class and a mean of 0.8470 (95% CI, 0.8432-0.8508) for the 'eyelid' class. The result for object detection-based approach was a mean of 0.4476 (95% CI, 0.4426-0.4533). Both artificial intelligence-based algorithms underestimated area, length ratio, tortuosity, widthmean, widthmedian, width10th, and width90th. Meibomian gland intensity was overestimated by both algorithms compared with the manual approach. The object detection-based algorithm seems to be as reliable as the manual approach only for Meibomian gland width10th calculation. Conclusions: The proposed approach can successfully segment Meibomian glands; however, to overcome problems with gland overlap and lack of image sharpness, the proposed method requires further development. The study presents another approach to utilizing automated, artificial intelligence-based methods in Meibomian gland health assessment that may assist clinicians in the diagnosis, treatment, and management of Meibomian gland dysfunction. Financial Disclosures: The authors have no proprietary or commercial interest in any materials discussed in this article.

12.
Clin Exp Optom ; : 1-11, 2023 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-37989323

RESUMEN

CLINICAL RELEVANCE: Evaluating how Meibomian glands can change in appearance has the potential to advance the understanding of Meibomian gland health and may lead to enhanced diagnosis and therapy. BACKGROUND: This work aimed to investigate Meibomian gland appearance after therapeutic Meibomian gland expression. METHODS: Fifteen subjects attended three study visits over a two-week period. Meibography was performed before and after therapeutic Meibomian gland expression, the following day, and 2 weeks after expression. Six central glands were used to calculate Meibomian gland morphological parameters such as gland length ratio, gland width, gland area, gland tortuosity, and gland contrast. A custom semi-automated image analysis software was used to calculate Meibomian gland metrics. Furthermore, a high-resolution imaging system was developed to capture clear images of the Meibomian glands, free of any artefacts, which were used for precise calculations of Meibomian gland contrast. RESULTS: The expression procedure had a significant impact on Meibomian gland contrast and length ratio immediately afterwards. The least square mean difference (95% CI) from baseline for Michelson contrast was -0.006 (-0.010, -0.001) and -1.048 (-2.063, -0.033) for simple contrast. The least square mean ratio of the gland length ratio immediately after the expression to baseline was 0.758 (0.618, 0.931). CONCLUSIONS: Following therapeutic expression, Meibomian glands exhibit reduced brightness and length. However, within 24 h, they appear to recover and return to their baseline state, indicating a relatively short recovery time. This sheds light on whether meibography is solely focused on capturing gland structure or if it also captures acinar activity. The hyperreflective properties of lipids suggest that the decrease in contrast observed after expression could be attributed to a reduction in the visualisation of acini activity. A decrease in Meibomian gland length ratio implies that the loss of gland structure following treatment may be indicative of a temporary structural alteration.

13.
Cont Lens Anterior Eye ; 46(6): 102068, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37919220

RESUMEN

PURPOSE: All neophyte contact lens wearers require training on how to handle contact lenses. Currently, almost no published information exists describing the most common approaches used by those involved in such training in soft contact lens wearers. This study aimed to gather information on the approaches taken by those conducting this training worldwide. METHODS: An online survey was created in English and translated to Spanish and distributed internationally via social media, conference attendees, and professional contacts. The anonymous survey included information on workplace setting of respondents, information about the typical approaches used for application and removal of soft contact lenses, length of the appointment, and success rate with their approach. Survey responses were received between May 2021 and April 2022. RESULTS: A total of 511 individuals completed the survey and responses were received from 31 countries with 48.7% from the UK. The most common approach taught for application was to have the patient hold the upper eyelashes (84.7%) and to hold the lower eyelid with the same hand as the lens (89.4%). Lenses were applied directly to the cornea by 57.7% of the respondents. The most common approach taught for lens removal was to drag the lens inferiorly from the cornea prior to removal (49.3%). Most respondents did not use videos to aid the teaching appointment (62.0%); however, they felt that their approach was successful in most cases (90). Application and removal training sessions lasted a median of 30 min and contact lenses were typically dispensed after the instructor witnessing successful application and removal three times. CONCLUSION: Various methods are adopted globally for training of application and removal of soft contact lenses, with many advising a patient-specific approach is required for success. The results of this survey provide novel insights into soft contact lens handling training in clinical practice.


Asunto(s)
Lentes de Contacto Hidrofílicos , Humanos , Córnea , Párpados , Encuestas y Cuestionarios
14.
Cont Lens Anterior Eye ; 46(5): 101887, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37460374

RESUMEN

PURPOSE: To determine clinical performance and the 'Willingness To Pay' for toric vs. spherical soft contact lenses in an astigmatic population. METHODS: In the clinical study, subjects with binocular low to moderate astigmatism (-0.75DC to -1.50DC) wore pairs of soft toric (Biofinity toric) and spherical (Biofinity) contact lenses in random sequence. Visual acuity (high and low contrast, monocular and binocular), subjective comfort and subjective vision were recorded. In the economics study, first subjects who had participated in the clinical study were presented with a series of randomised economic scenarios in order to determine their Willingness To Pay a premium (i.e. an increase) for toric lenses. Then, a similar set of scenarios were presented to a much larger group of online respondents and again, Willingness To Pay was established. RESULTS: For the four measures of visual acuity, the Biofinity toric lens out-performed the Biofinity spherical lens by 0.6 to 1.1 lines.. Subjective vision performance was statistically significantly better with the toric lens for the distance task only. Comfort scores were not significantly different. Similar findings for Willingness To Pay were established for the clinical subjects and for the online respondents. The Willingness To Pay premium (additional fee) for a monthly supply of toric lenses (over spherical lenses) was between £13 and £16, if a toric lens provides better vision and similar comfort, as shown in the clinical study. CONCLUSION: Consumers are willing to pay a monthly premium of around 50% to benefit from the typical experience of better vision and similar comfort for toric vs. spherical lenses. The level of additional cost for toric lenses compared to their spherical equivalents is less than this in the market, so eye care professionals should consider that toric lenses are delivering a greater clinical return than anticipated by wearers for the relatively small increase in price.


Asunto(s)
Astigmatismo , Lentes de Contacto Hidrofílicos , Humanos , Agudeza Visual , Refracción Ocular , Astigmatismo/terapia
15.
Eye Contact Lens ; 38(1): 36-42, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22146703

RESUMEN

OBJECTIVES: Tear film proteins have antimicrobial and other functions that may be lost after denaturation during contact lens wear. A new multipurpose solution has recently become available (Biotrue, Bausch + Lomb Inc., Rochester, NY), which contains protein-stabilizing agents including hyaluronic acid, poloxamine, and sulfobetaine 10, the latter used previously as a laboratory tool to renature proteins. We examine whether this new multipurpose solution formulation can prevent the denaturation of human lactoferrin and lysozyme at physiologic levels in response to a powerful denaturing challenge. METHODS: Human lactoferrin and lysozyme were treated with sodium dodecyl sulfate (SDS) either with or without an investigational version of the new multipurpose solution (without its two disinfectant agents) (investigational multipurpose solution [iMPS]). The structure was assessed by native-polyacrylamide gel electrophoresis (PAGE), differential scanning calorimetry (DSC), and fluorometry; additionally, antimicrobial activity against Pseudomonas aeruginosa and Staphylococcus aureus was measured. RESULTS: The iMPS prevented an SDS-induced shift in the native-PAGE banding position of lactoferrin. The SDS treatment substantially altered the lactoferrin DSC and fluorescence spectra, indicating that the protein had denatured. This change did not occur in the presence of iMPS. Lactoferrin and lysozyme showed antibacterial and bacteriolytic activity, which was abolished after SDS treatment; this loss of activity did not occur for proteins treated with iMPS. CONCLUSIONS: These data clearly show that the iMPS prevents the denaturation of physiologic levels of human lactoferrin and lysozyme by the strongly denaturing surfactant SDS and that stabilized proteins retain their function. We conclude that this solution has the capacity to stabilize the structure and function of tear proteins.


Asunto(s)
Soluciones para Lentes de Contacto/química , Proteínas del Ojo/química , Lactoferrina/química , Muramidasa/química , Análisis de Varianza , Recuento de Colonia Microbiana , Soluciones para Lentes de Contacto/farmacología , Electroforesis en Gel de Poliacrilamida , Estabilidad de Enzimas , Proteínas del Ojo/efectos de los fármacos , Humanos , Pruebas de Sensibilidad Microbiana , Pseudomonas aeruginosa/efectos de los fármacos , Pseudomonas aeruginosa/crecimiento & desarrollo , Dodecil Sulfato de Sodio/farmacología , Staphylococcus aureus/efectos de los fármacos , Staphylococcus aureus/crecimiento & desarrollo
16.
Cont Lens Anterior Eye ; 45(4): 101489, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-34281726

RESUMEN

PURPOSE: To investigate the ocular subclinical inflammatory response in two soft contact lens materials when used in combination with two different care systems ('solutions'). METHODS: Fifteen established soft contact lens wearers wore each of two lenses: Acuvue® 2 (CH) and Acuvue® Oasys® (SiH) or no lenses in random sequence for one week. Two care systems were used: a peroxide system: Oxysept 1 Step® (P) for the right lens and Opti-Free® Replenish® (MPS) for the left lens. After one week of lens/no lens wear, in vivo confocal microscopy (IVCM) of corneal and conjunctival regions was carried out. Density of presumed dendritic cells (DC) and 'white spots' (WS) were quantified. Impression cytology of the bulbar and upper eyelid margin conjunctivae was carried out and samples were analysed for CD45+, CD3+ and CD11c+ cells. RESULTS: The SiH + MPS combination showed a greater inflammatory response compared to SiH + P in seven out of 12 parameters investigated (p < 0.05). The remaining five were not statistically different between the two solutions. The converse was found for the CH lens, with four of the 12 parameters showing a greater response with the P solution compared to the MPS (p < 0.05). CONCLUSION: This study suggests that the SiH lens investigated demonstrated an upregulated response when used with a MPS compared to a P solution whereas the converse is true for the CH lens which showed a reduced response when used with a MPS compared to a P solution. This finding aids in the understanding of the biological underpinnings of manifest corneal inflammatory events during contact lens wear.


Asunto(s)
Lentes de Contacto Hidrofílicos , Hidrogel de Polietilenoglicol-Dimetacrilato , Córnea , Humanos , Inflamación/etiología , Visión Ocular
17.
Ocul Surf ; 25: 119-128, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35724917

RESUMEN

Meibography is a visualisation technique that has been used for over 40 years. There have been significant improvements in image quality, examination technique and image interpretation over this period. Although meibography has received sporadic reviews in the past, an updated review is timely due to the rapid recent rise of relevant technology and advances in both image processing and artificial intelligence. The primary aim of this paper is to review recent research into Meibomian gland imaging and update the community about the most relevant technologies and approaches used in the field.


Asunto(s)
Síndromes de Ojo Seco , Enfermedades de los Párpados , Inteligencia Artificial , Síndromes de Ojo Seco/diagnóstico , Enfermedades de los Párpados/diagnóstico , Humanos , Procesamiento de Imagen Asistido por Computador , Glándulas Tarsales/diagnóstico por imagen , Lágrimas
18.
Cont Lens Anterior Eye ; 45(5): 101516, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-34607768

RESUMEN

PURPOSE: To test the hypothesis that various subjective ocular and task-related parameters associated with wearing a face mask would be better in neophyte contact lens (CL) wear compared to habitual spectacle (Sp) wear. METHODS: Thirty participants were randomised to continue in Sp (n = 15) or wear somofilcon A daily disposable CL (n = 15) ('group'). A surgical face mask (Type II R) was worn for at least one hour per day on four or more days per week. After two weeks, participants completed the Quality of Life Impact of Refractive Correction Questionnaire (QIRC), a two-part face mask usability questionnaire and graded ocular-related symptoms using 0-100 visual analogue scales. RESULTS: There was no difference between groups for overall QIRC score but some individual question scores reflected better quality of life in the CL: 'outdoor activities', 'keep fit' and 'able to do things' (all p < 0.05). Differences in favour of the CL were seen for the following in the face mask usability questionnaire: 'breathing', 'heat', 'comfort on ears', 'overall comfort', 'walking', 'driving', 'reading', 'computer use', 'exercising' and 'socialising' (all p < 0.05). Significant differences were also seen for the 0-100 VAS symptoms probing vision quality in favour of the CL: glare, distance and near vision, fogging, restricted field of view and peripheral blur. CONCLUSION: This work supports anecdotal reports that CL are a better vision correction option than Sp when used in conjunction with a face mask. Participants reported a range of benefits to the CL/face mask combination for vision-related symptoms, breathing and heat-related symptoms and a number of day-to-day activities including walking, driving and exercising. All of the benefits relating to the CL are likely to result in improved adherence to face mask use. Overall, the findings of this work suggest that where possible, CL should be the preferred vision correction option for people using face masks.


Asunto(s)
Lentes de Contacto Hidrofílicos , Lentes de Contacto , Anteojos , Humanos , Máscaras , Satisfacción del Paciente , Calidad de Vida , Agudeza Visual
19.
Cont Lens Anterior Eye ; 45(4): 101469, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-34034960

RESUMEN

AIM: To determine if a gradual adaptation period is necessary for neophytes when fitted with modern hydrogel or silicone hydrogel reusable disposable contact lenses. METHOD: Across four sites, 74 neophytes (18-28 years) were randomly assigned to a reusable lens cleaned nightly with Opti-Free® Puremoist® multi-purpose contact lens solution: Proclear® (hydrogel) or Biofinity® (silicone hydrogel) and an adaptation schedule: fast (10 h wear from the first day) or gradual (4 h on the first day, increasing their wear time by 2 h on each subsequent day until they had reached 10 h). Masked investigators graded ocular surface physiology and non-invasive tear breakup time (NIBUT) and a range of comfort, vision and lens handling subjective ratings (0-100 visual analogue scales) were recorded at the baseline visit and after 10 h of lens wear, 4-6 days and 12-14 days after lens fitting. Subjective scores were also repeated after 7 days. RESULTS: There was no difference (p > 0.05) in ocular surface physiology or NIBUT between fast and gradual adaptation groups at any time point in either lens type with the exception of increased corneal staining (p = 0.019) in the silicone hydrogel fast adaptation group after 4-6 days, but was similar by 12-14 days. Subjective scores were also similar across the visits and lens types with the exception of 'lens awareness' (p = 0.019) which was less in the gradual versus the fast adaptation silicone hydrogel lens group at 12-14 days. CONCLUSION: There seems to be no clinical benefit for recommending a gradual adaptation period in new wearers fitted with modern soft reusable disposable contact lenses. The findings of this work add to a growing body of evidence suggesting that such advice is unnecessary in regular soft contact lens wear, which has important ramifications for the initial clinical management of these patients.


Asunto(s)
Lentes de Contacto Hidrofílicos , Hidrogel de Polietilenoglicol-Dimetacrilato , Humanos , Hidrogeles , Satisfacción del Paciente , Siliconas
20.
Optom Vis Sci ; 88(4): E534-8, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21378591

RESUMEN

PURPOSE: To quantify changes in visual acuity (VA) with soft toric contact lenses as a result of lens movement and/or rotational instability caused by versional eye movements. METHODS: A novel chart for vision assessment at near (40 cm) for soft toric contact lenses (VANT chart),consisting of a central, color-coded logMAR panel and eight peripheral letter targets set on a white background measuring 60 × 40 cm was constructed. In the developmental phase of the work, 10 subjects (20 eyes) wore 2 toric lenses in random order, and the impact of rapid and delayed eye versions in 8 directions of gaze on VANT acuity was investigated. In phase 2, 35 subjects (68 eyes) wore 4 toric lenses in random order, and a streamlined clinical protocol using the VANT chart was implemented. Standard assessments of toric lens fit and distance VA were also performed. RESULTS: Testing in the first phase showed no difference for change in VA for rapid vs. delayed version movements, (p = 0.17) but acuity reduction was greater for diagonal compared with horizontal/vertical versions (p = 0.06). As such, testing in phase 2 proceeded using rapid, diagonal versions only. In this second phase, there were differences for low-contrast distance VA measures between lens types (p = 0.02) and for both VANT baseline acuity (p = 0.03) and postversion acuity (p = 0.04), but no differences were found between lenses for magnitude of vision loss (p = 0.91), which was about one line. No relationship was established between the magnitude of vision loss and measured rotational stability (p = 0.75). CONCLUSIONS: This work has demonstrated that conventional approaches to measuring VA do not fully replicate the "real world" experience of soft toric lens wearers. The VANT chart has shown that VA is reduced immediately after versional eye movements and suggests that more dynamic methods of assessing visual performance should be considered for soft toric contact lens wearers, especially given the apparent inability of lens stability measurements to predict visual performance.


Asunto(s)
Lentes de Contacto Hidrofílicos , Agudeza Visual , Adulto , Estudios Cruzados , Movimientos Oculares , Femenino , Migración de Cuerpo Extraño/fisiopatología , Humanos , Masculino , Pruebas de Visión/instrumentación , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA