Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros

País de afiliación
Intervalo de año de publicación
1.
Echocardiography ; 32(10): 1455-62, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25604804

RESUMEN

INTRODUCTION: Training requirements for general cardiologists without echocardiographic expertise to perform focused cardiac ultrasound (FCU) with portable devices have not yet been defined. The objective of this study was to evaluate a training program to instruct cardiology residents to perform FCU with a hand-carried device (HCD) in different clinical settings. METHODS: Twelve cardiology residents were subjected to a 50-question test, 4 lectures on basic echocardiography and imaging interpretation, the supervised interpretation of 50 echocardiograms and performance of 30 exams using HCD. After this period, they repeated the written test and were administered a practical test comprising 30 exams each (360 patients) in different clinical settings. They reported on 15 parameters and a final diagnosis; their findings were compared to the HCD exam of a specialist in echocardiography. RESULTS: The proportion of correct answers on the theoretical test was higher after training (86%) than before (51%; P = 0.001). The agreement was substantial among the 15 parameters analyzed (kappa ranging from 0.615 to 0.891; P < 0.001). The percentage of correct interpretation was lower for abnormal (75%) than normal (95%) items, for valve abnormalities (85%) compared to other items (92%) and for graded scale (87%) than for dichotomous (95%) items (P < 0.0001, for all). For the final diagnoses, the kappa value was higher than 0.941 (P < 0.001; 95% CI [0.914, 0.955]). CONCLUSION: The training proposed enabled residents to perform FCU with HCD, and their findings were in good agreement with those of a cardiologist specialized in echocardiography.


Asunto(s)
Cardiología/educación , Ecocardiografía/instrumentación , Ecocardiografía/normas , Educación de Postgrado en Medicina , Sistemas de Atención de Punto , Competencia Clínica , Curriculum , Evaluación Educacional , Femenino , Humanos , Internado y Residencia , Masculino , Persona de Mediana Edad , Evaluación de Programas y Proyectos de Salud
2.
Echocardiography ; 31(3): 265-72, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24111730

RESUMEN

The left atrial volume index (LAVI) is a biomarker of diastolic dysfunction and a predictor of cardiovascular events. Three-dimensional echocardiography (3DE) is highly accurate for LAVI measurements but is not widely available. Furthermore, biplane two-dimensional echocardiography (B2DE) may occasionally not be feasible due to a suboptimal two-chamber apical view. Simplified single plane two-dimensional echocardiography (S2DE) could overcome these limitations. We aimed to compare the reliability of S2DE with other validated echocardiographic methods in the measurement of the LAVI. We examined 143 individuals (54 ± 13 years old; 112 with heart disease and 31 healthy volunteers; all with sinus rhythm, with a wide range of LAVI). The results for all the individuals were compared with B2DE-derived LAVIs and validated using 3DE. The LAVIs, as determined using S2DE (32.7 ± 13.1 mL/m(2)), B2DE (31.9 ± 12.7 mL/m(2)), and 3DE (33.1 ± 13.4 mL/m(2)), were not significantly different from each other (P = 0.85). The S2DE-derived LAVIs correlated significantly with those obtained using both B2DE (r = 0.98; P < 0.001) and 3DE (r = 0.93; P < 0.001). The mean difference between the S2DE and B2DE measurements was <1.0 mL/m(2). Using the American Society of Echocardiography criteria for grading LAVI enlargement (normal, mild, moderate, severe), we observed an excellent agreement between the S2DE- and B2DE-derived classifications (κ = 0.89; P < 0.001). S2DE is a simple, rapid, and reliable method for LAVI measurement that may expand the use of this important biomarker in routine echocardiographic practice.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Atrios Cardíacos/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Estudios de Cohortes , Ecocardiografía/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Tamaño de los Órganos , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
3.
Int J Cardiovasc Imaging ; 39(11): 2163-2171, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37592086

RESUMEN

To measure left ventricular (LV) global longitudinal strain (GLS) using speckle tracking echocardiography in idiopathic inflammatory myopathy (IIM) patients and to determine whether the LV GLS predicts outcomes in those patients. Prospective study consisted of a cross-sectional phase with 61 IIM patients and 32 individuals without IIM and longitudinal phase, in which patients were divided into two subgroups: 26 with reduced LV GLS and 35 with normal LV GLS; patients were followed for a mean of 25 months, and the occurrence of cardiovascular events and criteria for IIM activity were compared. The mean LV GLS (18.5 ± 2.9% vs. 21.6 ± 2.5%; p < 0.001) and right ventricle free wall strain (21.9 ± 6.1% vs. 27.5 ± 4.7%; p < 0.001) were lower in patients than in controls. The mean N-terminal pro B-type natriuretic peptide level was higher in patients than in controls. There were no differences regarding other cardiac involvement. Anti-Jo1 antibody was associated with general electrocardiographic abnormality and LV diastolic dysfunction. The subgroup with reduced GLS progressed with higher mean creatine phosphokinase, myositis disease activity assessment visual analogue scales, the physician's and patient's visual analogue scales, the health assessment questionnaire, and a higher proportion of relapses than the subgroup with normal GLS. There was no difference between the subgroups regarding cardiovascular events. The LV GLS appears to be useful for evaluating patients with IIM. Abnormal values are associated with more frequent relapses and increased disease activity during follow-up.


Asunto(s)
Miositis , Disfunción Ventricular Izquierda , Humanos , Pronóstico , Función Ventricular Izquierda , Estudios Prospectivos , Estudios Transversales , Valor Predictivo de las Pruebas , Ecocardiografía , Disfunción Ventricular Izquierda/diagnóstico por imagen , Miositis/diagnóstico por imagen , Recurrencia
4.
ERJ Open Res ; 9(3)2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37228270

RESUMEN

Rationale: Post-coronavirus disease 2019 (COVID-19) survivors frequently have dyspnoea that can lead to exercise intolerance and lower quality of life. Despite recent advances, the pathophysiological mechanisms of exercise intolerance in the post-COVID-19 patients remain incompletely characterised. The objectives of the present study were to clarify the mechanisms of exercise intolerance in post-COVID-19 survivors after hospitalisation. Methods: This prospective study evaluated consecutive patients previously hospitalised due to moderate-to-severe/critical COVID-19. Within mean±sd 90±10 days of onset of acute COVID-19 symptoms, patients underwent a comprehensive cardiopulmonary assessment, including cardiopulmonary exercise testing with earlobe arterialised capillary blood gas analysis. Measurements and main results: 87 patients were evaluated; mean±sd peak oxygen consumption was 19.5±5.0 mL·kg-1·min-1, and the tertiles were ≤17.0, 17.1-22.2 and ≥22.3 mL·kg-1·min-1. Hospitalisation severity was similar among the three groups; however, at the follow-up visit, patients with peak oxygen consumption ≤17.0 mL·kg-1·min-1 reported a greater sensation of dyspnoea, along with indices of impaired pulmonary function, and abnormal ventilatory, gas-exchange and metabolic responses during exercise compared to patients with peak oxygen consumption >17 mL·kg-1·min-1. By multivariate logistic regression analysis (receiver operating characteristic curve analysis) adjusted for age, sex and prior pulmonary embolism, a peak dead space fraction of tidal volume ≥29 and a resting forced vital capacity ≤80% predicted were independent predictors of reduced peak oxygen consumption. Conclusions: Exercise intolerance in the post-COVID-19 survivors was related to a high dead space fraction of tidal volume at peak exercise and a decreased resting forced vital capacity, suggesting that both pulmonary microcirculation injury and ventilatory impairment could influence aerobic capacity in this patient population.

5.
Int J Cardiovasc Imaging ; 34(4): 553-560, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29098525

RESUMEN

Heart failure (HF) is associated with morbidity and mortality. Real-time three-dimensional echocardiography (RT3DE) may offer additional prognostic data in patients with HF. The study aimed to evaluate the prognostic value of real-time three-dimensional echocardiography (RT3DE). This is a prospective study that included 89 patients with HF and left ventricular ejection fraction (LVEF) < 0.50 who were followed for 48 months. Left atrium and ventricular volumes and functions were evaluated by RT3DE. TDI and two-dimensional echocardiography parameters were also obtained. The endpoint was a composite of death, heart transplantation and hospitalization for acute decompensated HF. The mean age was 55 ± 11 years, and the LVEF was 0.32 ± 0.10. The composite endpoint occurred in 49 patients (18 deaths, 30 hospitalizations, one heart transplant). Patients with outcomes had greater left atrial volume (40 ± 16 vs. 32 ± 12 mL/m2; p < 0.01) and right ventricle diameter (41 ± 9 vs. 37 ± 8 mm, p = 0.01), worse total emptying fraction of the left atrium (36 ± 13% vs. 41 ± 11%; p = 0.03), LVEF (0.30 ± 0.09 vs. 0.34 ± 0.11; p = 0.02), right ventricle fractional area change (34.8 ± 12.1% vs. 39.2 ± 11.3%; p = 0.04), and greater E/e' ratio (19 ± 9 vs. 16 ± 8; p = 0.04) and systolic pulmonary artery pressure (SPAP) (50 ± 15 vs. 36 ± 11 mmHg; p < 0.01). In multivariate analysis, LVEF (OR 4.6; CI 95% 1.2-17.6; p < 0.01) and SPAP (OR 12.5; CI 95% 1.8-86.9; p < 0.01) were independent predictors of patient outcomes. LVEF and the SPAP were independent predictors of outcomes in patients with HF.


Asunto(s)
Ecocardiografía Doppler en Color , Ecocardiografía Tridimensional , Insuficiencia Cardíaca Sistólica/diagnóstico por imagen , Hemodinámica , Adulto , Anciano , Área Bajo la Curva , Supervivencia sin Enfermedad , Femenino , Insuficiencia Cardíaca Sistólica/mortalidad , Insuficiencia Cardíaca Sistólica/fisiopatología , Insuficiencia Cardíaca Sistólica/terapia , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Variaciones Dependientes del Observador , Oportunidad Relativa , Valor Predictivo de las Pruebas , Estudios Prospectivos , Curva ROC , Reproducibilidad de los Resultados , Factores de Riesgo , Volumen Sistólico , Factores de Tiempo , Función Ventricular Izquierda
6.
Sleep Med ; 16(8): 971-5, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26071851

RESUMEN

INTRODUCTION: The sleep of patients admitted to coronary care unit (CCU) may be compromised. A feasible and cost-effective tool to evaluate sleep in this scenario could provide important data. The aim of this study was to evaluate sleep with a questionnaire developed specifically for the CCU and to validate it with polysomnography (PSG). METHODS: Ninety-nine patients (68% male; 56 ± 10 years old) with acute coronary syndrome were included. PSG was performed within 36 h of admission. A specific 18-question questionnaire (CCU questionnaire) was developed and applied after the PSG. Cronbach's alpha test was used to validate the questionnaire. The Spearman test was used to analyze the correlation between the PSG variables and the questionnaire, and the Kruskal-Wallis test was used to compare the PSG variables among patients with good, regular, or poor sleep. RESULTS: The total sleep time was 265 ± 81 min, sleep efficiency 62 ± 18%, REM sleep 10 ± 7%, apnea/hypopnea index 15 ± 23, and the arousal index 24 ± 15. Cronbach's alpha test was 0.69. The CCU questionnaire showed correlation with the sleep efficiency evaluated by PSG (r: 0.52; p < 0.001). Sleep quality was divided into three categories according to the CCU questionnaire: patients with good sleep had a sleep efficiency of 72 ± 9%, better than those with a regular or poor sleep (60 ± 16% and 53 ± 20%, respectively; p < 0.01). CONCLUSION: The CCU questionnaire is a feasible and reliable tool to evaluate sleep in the CCU, showing correlation with the PSG sleep efficiency.


Asunto(s)
Unidades de Cuidados Coronarios , Trastornos del Sueño-Vigilia/diagnóstico , Síndrome Coronario Agudo/complicaciones , Síndrome Coronario Agudo/terapia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Polisomnografía , Reproducibilidad de los Resultados , Sueño , Trastornos del Sueño-Vigilia/etiología , Sueño REM , Encuestas y Cuestionarios/normas
7.
J Am Soc Echocardiogr ; 24(5): 526-32, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21353762

RESUMEN

BACKGROUND: Although there is anatomopathologic evidence of atrial involvement in Chagas cardiomyopathy (CCM), the impact in left atrial (LA) function is unknown. The aim of this study was to evaluate LA function in patients with CCM with real-time three-dimensional echocardiography (RT3DE) and to compare it with patients with idiopathic dilated cardiomyopathy (DCM). METHODS: A total of 30 patients with CCM, 30 patients with DCM, and 20 normal subjects used as the control group were studied. With the use of RT3DE, we measured LA maximum (maxLAV), minimum, and pre-atrial contraction volumes and calculated total and active LA emptying fractions. RESULTS: Left ventricular ejection fraction and mitral regurgitation were similar in both groups. MaxLAV/m(2) was larger in the CCM group than in the DCM group (76.9 ± 21.9 mL vs. 59.1 ± 26.0 mL; P < .01), and both were significantly larger than in the control group (P < .01). Total LA emptying fraction was lower in the CCM group than in the DCM group (0.30 ± 0.10 vs. 0.40 ± 0.12; P < .01), and both were lower than in the control group (P = .01). Active LA emptying fraction was also lower in the CCM group than in the DCM group (0.22 ± 0.09 vs. 0.28 ± 0.11; P < .01), and both were lower than in the control group (P = .01). The E/e' ratio was higher in the CCM group than in the DCM group (21 ± 10 vs. 15 ± 6; P < .01), and both were greater than in the control group (P < .01). In a multiple regression model, the E/e' ratio was the only independent predictor of a worsening active LA emptying fraction. CONCLUSION: LA function is more compromised in patients with CCM than in patients with DCM. This finding indicates a more diffuse and severe myocardial impairment in Chagas disease that is probably related to increased left ventricular filling pressures and atrial myopathy.


Asunto(s)
Función del Atrio Izquierdo , Cardiomiopatía Dilatada/diagnóstico por imagen , Cardiomiopatía Chagásica/diagnóstico por imagen , Sistemas de Computación , Atrios Cardíacos/diagnóstico por imagen , Cardiomiopatía Dilatada/patología , Estudios de Casos y Controles , Cardiomiopatía Chagásica/patología , Femenino , Atrios Cardíacos/patología , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/patología , Análisis Multivariante , Pronóstico , Medición de Riesgo/métodos , Índice de Severidad de la Enfermedad , Volumen Sistólico , Factores de Tiempo , Ultrasonografía , Función Ventricular Izquierda
8.
Rev. bras. ecocardiogr. imagem cardiovasc ; 22(2): 40-48, abr.-jun. 2009. ilus, tab
Artículo en Portugués | LILACS | ID: lil-514954

RESUMEN

A detecção e quantificação da dissincronia cardíaca têm papel central na indicação da terapia de ressincronização. O ecocardiograma é o método mais utilizado para esse fim, porém nenhum parâmetro ecocardiografico, até o momento, mostrou superioridade em relação aos demais. Esse artigo visa a enfatizar as vantagens e limitações associadas a cada método, além de propor uma abordagem sequencial na avaliação da sincronia cardíaca.


Asunto(s)
Humanos , Ecocardiografía Doppler/métodos , Ecocardiografía Doppler , Ecocardiografía/métodos , Ecocardiografía
9.
Rev. bras. ecocardiogr ; 21(4): 16-22, out.-nov. 2008. ilus, tab
Artículo en Portugués | LILACS | ID: lil-497518

RESUMEN

Introdução: A pressão sistólica da artéria pulmonar (PSAP), aferida com ecocardiografia Doppler (ED), é estimada pelo refluxo tricúspide, o qual nem sempre está presente. Por causa disso, outros métodos podem ser utilizados. Objetivo: Determinar o valor dos demais métodos pela ED para o diagnóstico de hipertensão pulmonar(HP). Métodos: Foram incluídos pacientes encaminhados para estudo ecodopplercardiográfico, nos quais foi possível determinar a pressão pulmonar pelos métodos de refluxo tricúspide, refluxo pulmonar (pressão média; gradiente de pressão inicial - PMPIP; pressão diatólica, gradiente diastólico fical - PSPIP), e tempo de aceleração de fluxo na via de saída do ventrículo direito (PMPTAC). Foram analisados: sensibilidade, especificidade, valores preditivos positivo (VPP) e negativo(VPN), acurácia e concordância pelo teste Kappa, além de correlação, sendo a determinação da pressão pulmonar pelo método do refluxo tricúspide considerado padrão ouro. Resultados: Foram incluídos 28 pacientes, com média etária de 55 anos. A PSAP foi 40 +- 15,5 mmHg a PMPIP foi 17 +- 10,2 mmHg;a PDPIP foi 12,7 +- 7 mmHg;a PMPTAC foi 23 +- 13,9 mmHg. Os índices de correlação (r) com a PSAP da PMPIP, PDPIP e PMPTAC foram 0,73; 0,77 e 0,79, respectivamente. A sensibilidade foi de 73 por cento, 66 por cento e 78 por cento; a especificidade 100 por cento; o VPP 100 por cento, e 88 por cento;VPN 85 por cento, 82 por cento, 82 por cento; a acurácia 89 por cento, 87 por cento e 84 por cento; a concordância (Kappa) 0,77, 071 e 0,61, respectivamente. Conclusão: Com relação ao método do refluxo tricúspide, os outros métodos para avaliação da pressão pulmonar demonstraram boa correlação, moderada sensibilidade, alta especificidade e alta acurácia para o diagnóstico de HP e podem ser usados na prática clínica.


Asunto(s)
Humanos , Adulto , Persona de Mediana Edad , Hipertensión Pulmonar/diagnóstico , Hipertensión Pulmonar/terapia , Ecocardiografía Doppler/métodos , Ecocardiografía Doppler , Arteria Pulmonar
10.
In. Kalil Filho, Roberto; Fuster, Valetim; Albuquerque, Cícero Piva de. Medicina cardiovascular reduzindo o impacto das doenças / Cardiovascular medicine reducing the impact of diseases. São Paulo, Atheneu, 2016. p.73-88.
Monografía en Portugués | LILACS | ID: biblio-971529
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA