Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Sensors (Basel) ; 19(6)2019 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-30884875

RESUMEN

The requirements of the Water Framework Directive to monitor diclofenac (DCF) concentration in surface water impose the need to find advanced fast and simple analysis methods. Direct voltammetric/amperometric methods could represent efficient and practical solutions. Fullerene⁻carbon nanofibers in paraffin oil as a paste electrode (F⁻CNF) was easily obtained by simple mixing and tested for DCF detection using voltammetric and amperometric techniques. The lowest limit of detection of 0.9 nM was achieved by applying square-wave voltammetry operated under step potential (SP) of 2 mV, modulation amplitude (MA) of 10 mV, and frequency of 25 Hz, and the best sensitivity was achieved by four-level multiple pulsed amperometry (MPA) that allowed in situ reactivation of the F⁻CNF electrode. The selection of the method must take into account the environmental quality standard (EQS), imposed through the "watchlist" of the Water Framework Directive as 0.1 µg·L-1 DCF. A good improvement of the electroanalytical parameters for DCF detection on the F⁻CNF electrode was achieved by applying the preconcentration step for 30 min before the detection step, which assured about 30 times better sensitivity, recommending its application for the monitoring of trace levels of DCF. The electrochemical behavior of F⁻CNF as a pseudomicroelectrode array makes it suitable for practical application in the in situ and real-time monitoring of DCF concentrations in water.


Asunto(s)
Carbono/química , Diclofenaco/análisis , Técnicas Electroquímicas/métodos , Fulerenos/química , Nanofibras/química , Electrodos , Límite de Detección , Microscopía Electrónica de Rastreo , Espectroscopía Infrarroja por Transformada de Fourier , Contaminantes Químicos del Agua/análisis
2.
Sensors (Basel) ; 19(24)2019 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-31817245

RESUMEN

A homoleptic ionic Cu(I) coordination complex that was based on 2,2'-biquinoline ligand functionalized with long alkyl chains (Cu(I)-C18) was used as a precursor to modify a carbon nanofiber paste electrode (Cu-C18/CNF). Randomized copper oxide microelectrode arrays dispersed within carbon nanofiber paste (CuOx/CNF) were obtained by electrochemical treatment of Cu-C18/CNF while using cyclic voltammetry (CV). The CuOx/CNF exhibited high electrocatalytic activity towards glucose oxidation at +0.6 V and +1.2 V vs. Ag/AgCl. Infrared Spectroscopy (FTIR) and scanning electron microscopy (SEM) characterized the electrodes composition. Cyclic voltammetry (CV), square wave-voltammetry (SWV), and multiple-pulsed amperometry (MPA) techniques provided optimized conditions for glucose oxidation and detection. A preconcentration step that involved 10 minutes accumulation at open circuit potential before SWV running led to the lowest limit of detection and the highest sensitivity for glucose detection (5419.77 µA·mM-1·cm-2 at + 1.1 V vs. Ag/AgCl) vs. Cu-based electrodes reported to date in literature.


Asunto(s)
Complejos de Coordinación/química , Cobre/química , Técnicas Electroquímicas/métodos , Glucosa/análisis , Nanofibras/química , Carbono/química , Catálisis , Límite de Detección , Análisis por Micromatrices , Oxidación-Reducción
3.
Sensors (Basel) ; 17(9)2017 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-28878151

RESUMEN

Monitoring of pesticide residues in food, beverages, and the environment requires fast, versatile, and sensitive analyzing methods. Direct electrochemical detection of pesticides could represent an efficient solution. Adequate electrode material, electrochemical technique, and optimal operation parameters define the detection method for practical application. In this study, cyclic voltammetric and differential pulse voltammetric techniques were used in order to individually and simultaneously detect two pesticides, i.e., carbaryl (CR) and paraquat (PQ), from an acetate buffer solution and also from natural apple juice. A graphene-modified boron-doped diamond electrode, denoted BDDGR, was obtained and successfully applied in the simultaneous detection of CR and PQ pesticides, using the differential pulse voltammetric technique with remarkable electroanalytical parameters in terms of sensitivity: 33.27 μA μM −1 cm −2 for CR and 31.83 μA μM −1 cm −2 for PQ. These outstanding results obtained in the acetate buffer supporting electrolyte allowed us to simultaneously detect the targeted pesticides in natural apple juice.

4.
Sensors (Basel) ; 16(10)2016 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-27763509

RESUMEN

In this study, the detection protocols for the individual, selective, and simultaneous determination of ibuprofen (IBP) and diclofenac (DCF) in aqueous solutions have been developed using HKUST-1 metal-organic framework-carbon nanofiber composite (HKUST-CNF) electrode. The morphological and electrical characterization of modified composite electrode prepared by film casting was studied by scanning electronic microscopy and four-point-probe methods. The electrochemical characterization of the electrode by cyclic voltammetry (CV) was considered the reference basis for the optimization of the operating conditions for chronoamperometry (CA) and multiple-pulsed amperometry (MPA). This electrode exhibited the possibility to selectively detect IBP and DCF by simple switching the detection potential using CA. However, the MPA operated under optimum working conditions of four potential levels selected based on CV shape in relation to the potential value, pulse time, and potential level number, and order allowed the selective/simultaneous detection of IBP and DCF characterized by the enhanced detection performance. For this application, the HKUST-CNF electrode exhibited a good stability and reproducibility of the results was achieved.

5.
Sensors (Basel) ; 15(6): 14526-38, 2015 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-26102487

RESUMEN

This work reported new voltammetric/amperometric-based protocols using a commercial boron-doped diamond (BDD) electrode for simple and fast simultaneous detection of sulfide and nitrite from water. Square-wave voltammetry operated under the optimized working conditions of 0.01 V step potential, 0.5 V modulation amplitude and 10 Hz frequency allowed achieving the best electroanalytical parameters for the simultaneous detection of nitrite and sulfide. For practical in-field detection applications, the multiple-pulsed amperometry technique was operated under optimized conditions, i.e., -0.5 V/SCE for a duration of 0.3 s as conditioning step, +0.85 V/SCE for a duration of 3 s that assure the sulfide oxidation and +1.25 V/SCE for a duration of 0.3 s, where the nitrite oxidation occurred, which allowed the simultaneously detection of sulfide and nitrite without interference between them. Good accuracy was found for this protocol in comparison with standardized methods for each anion. Also, no interference effect was found for the cation and anion species, which are common in the water matrix.

6.
Sensors (Basel) ; 13(6): 7296-307, 2013 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-23736851

RESUMEN

The present paper aims to miniaturize a graphite-epoxy and synthetic zeolite-modified graphite-epoxy composite macroelectrode as a quasi-microelectrode aiming in vitro and also, envisaging in vivo simultaneous electrochemical detection of dopamine (DA) and ascorbic acid (AA) neurotransmitters, or DA detection in the presence of AA. The electrochemical behavior and the response of the designed materials to the presence of dopamine and ascorbic acid without any protective membranes were studied by cyclic voltammetry and constant-potential amperometry techniques. The catalytic effect towards dopamine detection was proved for the synthetic zeolite-modified graphite-epoxy composite quasi-microelectrode, allowing increasing the sensitivity and selectivity for this analyte detection, besides a possible electrostatic attraction between dopamine cation and the negative surface of the synthetic zeolite and electrostatic repulsion with ascorbic acid anion. Also, the synthetic zeolite-modified graphite-epoxy composite quasi-microelectrode gave the best electroanalytical parameters for dopamine detection using constant-potential amperometry, the most useful technique for practical applications.


Asunto(s)
Ácido Ascórbico/análisis , Dopamina/análisis , Técnicas Electroquímicas , Compuestos Epoxi/química , Grafito/química , Zeolitas/química , Microelectrodos
7.
J Environ Sci (China) ; 25(4): 838-47, 2013 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-23923795

RESUMEN

This work describes the electrochemical behaviour of ibuprofen on two types of multi-walled carbon nanotubes based composite electrodes, i.e., multi-walled carbon nanotubes-epoxy (MWCNT) and silver-modified zeolite-multi-walled carbon nanotubes-epoxy (AgZMWCNT) composites electrodes. The composite electrodes were obtained using two-roll mill procedure. SEM images of surfaces of the composites revealed a homogeneous distribution of the composite components within the epoxy matrix. AgZMWCNT composite electrode exhibited the better electrical conductivity and larger electroactive surface area. The electrochemical determination of ibuprofen (IBP) was achieved using AgZMWCNT by cyclic voltammetry, differential-pulsed voltammetry, square-wave voltammetry and chronoamperometry. The IBP degradation occurred on both composite electrodes under controlled electrolysis at 1.2 and 1.75 V vs. Ag/AgCl, and IBP concentration was determined comparatively by differential-pulsed voltammetry, under optimized conditions using AgZMWCNT electrode and UV-Vis spectrophotometry methods to determine the IBP degradation performance for each electrode. AgZMWCNT electrode exhibited a dual character allowing a double application in IBP degradation process and its control.


Asunto(s)
Técnicas Electroquímicas/métodos , Compuestos Epoxi/química , Ibuprofeno/aislamiento & purificación , Nanotubos de Carbono/química , Contaminantes Químicos del Agua/aislamiento & purificación , Agua/química , Electrodos , Electrólitos/química , Ibuprofeno/química , Microscopía Electrónica de Rastreo , Nanotubos de Carbono/ultraestructura , Oxidación-Reducción , Contaminantes Químicos del Agua/química
8.
Materials (Basel) ; 16(5)2023 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-36903061

RESUMEN

The synthesis, as well as the mesomorphic and electrochemical properties, of a hetero-bimetallic coordination complex able to self-assemble into a columnar liquid crystalline phase is reported herein. The mesomorphic properties were investigated by polarized optical microscopy (POM), differential scanning calorimetry (DSC) and Powder X-ray diffraction (PXRD) analysis. Electrochemical properties were explored by cyclic voltammetry (CV), relating the hetero-bimetallic complex behaviour to previously reported analogous monometallic Zn(II) compounds. The obtained results highlight how the presence of the second metal centre and the supramolecular arrangement in the condensed state pilot the function and properties of the new hetero-bimetallic Zn/Fe coordination complex.

9.
Analyst ; 137(3): 641-7, 2012 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-22159176

RESUMEN

A non-enzymatic direct electrochemical glycerol detection method at a commercial boron-doped diamond (BDD) electrode in 0.1 M NaOH supporting electrolyte was developed. All the used electrochemical techniques proved useful features for the oxidation and direct amperometric determination of glycerol at a BDD electrode in 0.1 M NaOH aqueous solution. It was found that the direct electrooxidation of glycerol on the BDD electrode requires both adsorbed glycerol and hydroxyls at the electrode surface. Also, the sp(2) carbon did not allow enhancement of the glycerol oxidation process. The electronalytical sensitivity for the determination of glycerol at the BDD electrode ranged from 0.040 to 0.226 µA mM(-1) as a function of the technique used. The highest electroanalytical sensitivity for the determination of glycerol at the BDD electrode was reached in batch system amperometric quantification under stirring conditions. Performed recovery studies indicated that it is possible to determine glycerol in real samples, and the proposed batch system analysis-based methodology can be a valuable tool for practical glycerol analysis.


Asunto(s)
Boro/química , Diamante , Electroquímica/métodos , Electrodos , Glicerol/análisis
10.
Sensors (Basel) ; 12(6): 7033-46, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22969335

RESUMEN

The aim of this study was the preparation, characterization, and application of a multi-wall carbon nanotubes-epoxy composite electrode (MWCNT-EP) with 25%, wt. MWCNTs loading for the voltammetric/amperometric determination of pentachlorophenol (PCP) in aqueous solutions. The structural and morphological aspects of the MWCNT-EP composite electrode were examined by scanning electron microscopy. The electrical properties were characterized by direct-current conductivity measurements in relation with the percolation threshold. The electrochemical behavior of PCP at the MWCNT-EP composite electrode was investigated using cyclic voltammetry in 0.1 M Na2SO4 supporting electrolyte in order to establish the parameters for amperometric/voltammetric determination of PCP. The linear dependence of current vs. PCP concentrations was reached in a wide concentration range from 0.2 to 12 µM PCP using cyclic voltammetry, differential-pulsed voltammetry, square-wave voltammetry, chronoamperometry, and multiple-pulsed amperometry techniques. The best electroanalytical performances of this composite electrode were achieved using a pre-concentration/square-wave voltammetric technique and also multiple-pulsed amperometry techniques envisaging the practical applications. The ease of preparation, high sensitivity, and stability of this composite electrode should open novel avenues and applications for fabricating robust sensors for detection of many important species.

11.
Sci Total Environ ; 846: 157412, 2022 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-35853524

RESUMEN

Simple and fast simultaneous quantifications in water of anti-inflammatory drugs, which belong to the emerging pollutants, represents a great challenge for water quality control. The development of electrochemical methods to meet the simultaneous and concomitant detection requirements depends mainly on the electrode material. The fullerene­carbon nanofiber (FULL/CNF) and graphene­carbon nanotubes (GR/CNT) paste electrodes as sensing elements were employed for the first time for the determination of diclofenac (DCF), naproxen (NPX) and ibuprofen (IBP) simultaneously and concomitantly. The comparative morphostructural and electrochemical characterizations of both electrodes were achieved by scanning electron microscopy (SEM) and cyclic voltammetry (CV). Differential-pulsed voltammetry (DPV), chronoamperometry (CA) and multiple-pulsed amperometry (MPA) were used for detection tests. FULL/CNF electrode was suitable to develop a simultaneous DPV-based detection methodology that allowed reaching the lowest limit of detections of 0.230 nM for DCF, 0.310 nM for NPX and 0.180 nM for IBP. GR/CNT electrode did not provide stability for DPV-based detection, but the lowest limits of detection of 0.149 nM for DCF, 0.809 nM for NPX and 0.640 nM for IBP were achieved by MPA-based methodology. Both electrodes, linked to specific detection technique, showed good reproducibility, stability and ability to measure DCF, NPX and IBP simultaneously in aqueous solution. The satisfactory results achieved by analysis of real surface water sample (Bega River, Timisoara city, Romania) indicated that the proposed voltammetric and amperometric methodologies using both electrodes have great potential for practical applications in analysis of different water samples.


Asunto(s)
Fulerenos , Grafito , Nanotubos de Carbono , Antiinflamatorios no Esteroideos/química , Diclofenaco/química , Técnicas Electroquímicas/métodos , Electrodos , Ibuprofeno/química , Nanotubos de Carbono/química , Naproxeno/química , Reproducibilidad de los Resultados
12.
Nanomaterials (Basel) ; 12(23)2022 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-36500838

RESUMEN

A metallomesogen based on an Zn(II) coordination complex was employed as precursor to obtain a complex matrix nanoplatform for the fabrication of a high-performance electrochemical hybrid sensor. Three representative paste electrodes, which differ by the weight ratio between Zn(II) metallomesogen and carbon nanotubes (CNT), i.e., PE_01, PE_02 and PE_03, were obtained by mixing the materials in different amounts. The composition with the largest amount of CNT with respect to Zn complex, i.e., PE_03, gives the best electrochemical signal for uric acid detection by cyclic voltammetry in an alkaline medium. The amphiphilic structure of the Zn(II) coordination complex likely induces a regular separation between the metal centers favoring the redox system through their reduction, followed by stripping, and is characterized by enhanced electrocatalytic activity towards uric acid oxidation. The comparative detection of uric acid between the PE_03 paste electrode and the commercial zinc electrode demonstrated the superiority of the former, and its great potential for the development of advanced electrochemical detection of uric acid. Advanced electrochemical techniques, such as differential-pulsed voltammetry (DPV) and square-wave voltammetry (SWV), allowed for the highly sensitive detection of uric acid in aqueous alkaline solutions. In addition, a good and fast amperometric signal for uric acid detection was achieved by multiple-pulsed amperometry, which was validated by urine analysis.

13.
Artículo en Inglés | MEDLINE | ID: mdl-35010286

RESUMEN

Sodium diclofenac (DCF) presence reported in water use cycle at various concentrations including trace levels necessitates continuous development of advanced analytical method for its determination. In this work, ease electrochemical methods for DCF determination based on voltammetric and amperometric techniques were proposed using a simple combination of graphene with multi-walled carbon nanotubes as paste electrode. Integration of the graphene with multi-walled carbon nanotubes enlarged the electroactive surface area of the electrode and implicitly enhanced the electrochemical response for DCF determination. On the basis of the sorption autocatalytic effect manifested at low concentration of DCF, we found that the preconcentration step applied prior to differential-pulsed voltammetry (DPV) and multiple-pulsed amperometry (MPA) allowed for the enhancement of the electroanalytical performance of the DCF electrochemical detections, which were validated by testing in tap water. The lowest limit of detection (LOD) of 1.40 ng·L-1 was found using preconcentration prior to DPV under optimized operating conditions, which is better than that reached by other carbon-based electrodes reported in the literature.


Asunto(s)
Grafito , Nanotubos de Carbono , Diclofenaco , Técnicas Electroquímicas , Electrodos , Agua
14.
Nanomaterials (Basel) ; 11(6)2021 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-34198696

RESUMEN

A new electrochemical sensor designed by modifying the commercial boron-doped diamond (BDD) electrode with graphene oxide (GO) reduced electrochemically and further electrodecorated with silver (Ag), named the Ag/GO/BDD electrode, was selected among a series of the BDD, GOelectroreduced onto BDD (GO/BDD) and silver electrodeposited onto BDD (Ag/BDD) electrodes for the detection of tetracycline (TC) in aqueous solution. The best results regarding the sensitivity of 46.6 µA·µM-1·cm-2 and the lowest limit of detection of 5 nM was achieved using square-wave voltammetry (SWV) operated at the step potential of 5 mV, modulation amplitude of 200 mV and the frequency of 10 Hz in alkaline medium. The application of the alkaline supporting electrolyte-based procedure is limited for water monitoring due to the presence of chloride that interferes with TC detection; however, it can be applied for quantitative determination of pharmaceutical formulations. 0.1 M Na2SO4 supporting electrolyte eliminated chloride interference and can be used for the application of Ag/GO/BDD in practical detection of TC in water.

15.
Nanomaterials (Basel) ; 11(11)2021 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-34835559

RESUMEN

Two paste electrodes based on graphene quantum dots and carbon nanotubes (GRQD/CNT) and one modified with a homoleptic liquid crystalline Cu(I) based coordination complex (Cu/GRQD/CNT) were obtained and morphostructurally and electrochemically characterized in comparison with simple CNT electrode (CNT) for doxorubicine (DOX) detection in aqueous solutions. GRQD/CNT showed the best electroanalytical performance by differential pulse voltammetry technique (DPV). Moreover, applying a preconcentration step prior to detection stage, the lowest limit of detection (1 ng/L) and the highest sensitivity (216,105 µA/mg·L-1) in comparison with reported literature data were obtained. Cu/GRQD/CNT showed good results using multiple pulse amperometry technique (MPA) and a favorable shifting of the potential detection to mitigate potential interferences. Both GRQD-based paste electrodes have a great potential for practical utility in DOX determination in water at trace concentration levels, using GRQD/CNT with DPV and in pharmaceuticals formulations using Cu/GRQD/CNT with MPA.

16.
Nanomaterials (Basel) ; 11(3)2021 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-33804252

RESUMEN

CuBi2O4 synthesized by thermolysis of a new Bi(III)-Cu(II) oxalate coordination compound, namely Bi2Cu(C2O4)4·0.25H2O, was tested through its integration within carbon nanofiber paste electrode, namely CuBi/carbon nanofiber (CNF), for the electrochemical detection of amoxicillin (AMX) in the aqueous solution. Thermal analysis and IR spectroscopy were used to characterize a CuBi2O4 precursor to optimize the synthesis conditions. The copper bismuth oxide obtained after a heating treatment of the precursor at 700 °C/1 h was investigated by an X-ray diffraction and scanning electron microscopy. The electrochemical behavior of CuBi/CNF in comparison with CNF paste electrode showed the electrocatalytic activity of CuBi2O4 toward amoxicillin detection. Two potential detections, with one at the potential value of +0.540 V/saturated calomel electrode (SCE) and the other at the potential value of -1.000 V/SCE, were identified by cyclic voltammetry, which were exploited to develop the enhanced voltammetric and/or amperometric detection protocols. Better electroanalytical performance for AMX detection was achieved for CuBi/CNF using differential-pulsed and square-wave voltammetries than others reported in the literature. Very nice results obtained through anodic and cathodic currents recorded at +0.750 V/SCE and -1.000 V/SCE in the same time period using a pseudo multiple-pulsed amperometry technique showed the great potential of the CuBi/CNF paste electrode for practical applications in amoxicillin detection in aqueous solutions.

17.
Materials (Basel) ; 13(9)2020 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-32365678

RESUMEN

The perovskite-type lanthanum ferrite, LaFeO3, has been prepared by thermal decomposition of in situ obtained lanthanum ferrioxalate compound precursor, LaFe(C2O4)3·3H2O. The oxalate precursor was synthesized through the redox reaction between 1,2-ethanediol and nitrate ion and characterized by chemical analysis, infrared spectroscopy, and thermal analysis. LaFeO3 obtained after the calcination of the precursor for at least 550-800 °C/1 h have been investigated by X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM), and high-resolution transmission electron microscopy (HRTEM). A boron-doped diamond electrode (BDD) modified with LaFeO3 ceramic powders at 550 °C (LaFeO3/BDD) by simple immersion was characterized by cyclic voltammetry and tested for the voltammetric and amperometric detection of capecitabine (CCB), which is a cytostatic drug considered as an emerging pollutant in water. The modified electrode exhibited a complex electrochemical behaviour by several redox systems in direct relation to the electrode potential range. The results obtained by cyclic voltammetry (CV), differential-pulsed voltammetry (DPV), and multiple-pulsed amperometry proved the electrocatalytic effect to capecitabine oxidation and reduction and allowed its electrochemical detection in alkaline aqueous solution.

18.
Sensors (Basel) ; 8(7): 4330-4349, 2008 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-27879939

RESUMEN

In this paper, the electrochemical behaviour of several parabens preservatives, i.e. esters of p-hydroxybenzoic acid, methyl-, ethyl- and propyl-4-hydroxybenzoates as methyl-, ethyl- and propyl-parabens (MB, EB, and PB), has been investigated at a commercial boron-doped diamond electrode (BDDE), especially in the anodic potential range, in both hydro-alcoholic and aqueous media. The cyclic voltammetric and chronoamperometric measurements yielded calibration plots with very good linearity (R2 between 0.990 and 0.998) and high sensitivity, useful for detection and analytical applications. The determination of the characteristics of individual compounds, of an "overall paraben index", the assessment of the stability and the saturation solubility in water, and the amperometric sensing and determination in double distilled, tap and river water matrix of the relatively slightly soluble investigated parabens have been carried out using electrochemical alternative. Estimated water solubility was correlated with the octanol-water partition coefficient. Several ideas regarding stability and persistence of the presumptive eco-toxic investigated preservatives in the environment or water systems have been adjacently discussed.

19.
Sensors (Basel) ; 8(9): 5806-5819, 2008 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-27873841

RESUMEN

In this paper, a modified expanded graphite composite electrode based on natural zeolitic volcanic tuff modified with silver (EG-Ag-Z-Epoxy) was developed. Cyclic voltammetry measurements revealed a reasonably fast electron transfer and a good stability of the electrode in 0.1 M NaOH supporting electrolyte. This modified electrode exhibited moderate electrocatalytic effect towards urea oxidation, allowing its determination in aqueous solution. The linear dependence of the current versus urea concentration was reached using square-wave voltammetry in the concentrations range of urea between 0.2 to 1.4 mM, with a relatively low limit of detection of 0.05 mM. A moderate enhancement of electroanalytical sensitivity for the determination of urea at EG-Ag-Z-Epoxy electrode was reached by applying a chemical preconcentration step prior to voltammetric/amperometric quantification.

20.
Sensors (Basel) ; 7(11): 2626-2635, 2007 Nov 05.
Artículo en Inglés | MEDLINE | ID: mdl-28903250

RESUMEN

Electrodes based on carbon, i.e., expanded graphite (20%, wt.)-epoxy composite(20EG-Epoxy) and expanded graphite (20%, wt.)-polystyrene composite (20EG-PS) havebeen prepared, characterized using scanning electron microscopy (SEM) and cyclicvoltammetry (CV), and tested as anodic sensors. The electrodes exhibited good mechanicalresistance and low electrical resistances. Scan rate dependent cyclic voltammetry responsesat 20EG-Epoxy and 20EG-PS composite electrodes, which were exemplified for thiourea(TU), a toxic sulphur organic compound selected as testing target analyte in 0.1 M Na2SO4 supporting electrolyte, were investigated. The obtained voltammetric data were inaccordance with those for a random array of microelectrodes. The voltammetric andchronoamperometric detection results of TU in tap water samples, without a supplementaryaddition of supporting electrolyte, at 20EG-Epoxy electrode proved its use for directanalysis of environmental samples.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA