Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 99(7): 2117-2124, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35395142

RESUMEN

Rescue transcatheter aortic valve replacement (TAVR) in patients with cardiogenic shock is challenging, and there is limited literature on these critical patients. The aim of this study was to determine the characteristics and outcomes of patients undergoing TAVR, feasibility and safety of the procedure, and 1-year mortality factors. Thirty-eight patients with severe aortic disease and cardiogenic shock admitted to two French hospitals from 2015 to 2019 were included. The patients were critical, 78.9% of them had a left ventricular ejection fraction of <30%, and all of them received inotropic support. "Valve-in-valve" procedures were performed in 15.8% and 13.2% underwent balloon aortic valvuloplasty before TAVR. Edwards Sapien3® and Medtronic CoreValve EvolutR® were used. The survival probability remained reasonable for patients with cardiogenic shock who underwent rescue TAVR. The 30-day mortality rate was 7.9% and 21.1% at 1 year. No patient died during the intervention. The procedure was safe, with few complications except for acute kidney failure, the development of a left bundle branch block, and the need for pacemaker implantation. Both functional and echocardiographic results were good at 1 year, although 29% of the patients underwent rehospitalization within 1 year. The development of a left bundle branch block was found to be a mortality risk factor. This procedure is a safe and effective therapy with acceptable survivorship in critically ill patients. The benefits to their quality of life should be evaluated in future studies, and the need for providing early cardiac resynchronization therapy must be emphasized.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Arritmias Cardíacas , Bloqueo de Rama/etiología , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Calidad de Vida , Estudios Retrospectivos , Factores de Riesgo , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
2.
Catheter Cardiovasc Interv ; 99(6): 1829-1838, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35324050

RESUMEN

OBJECTIVES: Report contemporary outcomes in patients included in the Mitragister registry and treated with transcatheter mitral valve implantation for failed surgical annuloplasty rings or deteriorated bioprosthesis. BACKGROUND: Midterm survival rates have been reported, but little is known about contemporary morbimortality endpoints. METHODS: The primary safety outcome was the technical success rate. The primary efficacy composite endpoint was a composite of cardiovascular mortality and heart failure hospitalizations. RESULTS: From 2016 to 2021, 102 patients (median age: 81 [74;84] years, 61% female, Euroscore II 11.0% [7.8;16.0]) undergoing valve-in-valve (ViV; n = 89) or valve-in-ring (ViR; n = 13) procedures were consecutively included. At baseline, ViR group patients had worse left ventricular ejection fraction (50% vs. 60%; p = 0.004) and more frequently severe regurgitation (46% vs. 15%; p = 0.014). The primary safety outcome was 95%: 77% and 98% in the ViR and ViV populations, respectively, (p = 0.014). At intermediate follow-up (6-12 months) clinical improvement was notable, 88% of the patients were in NYHA class ≤ II (vs. 25% at baseline; p < 0.001). At a mean follow-up of 17.1 ± 11.0 months, the primary efficacy composite reached 27%. By multivariate analysis, paravalvular leak (PVL) was the only independent predictor (hazard ratio: 2.39, 95% confidence interval: 1.08-5.29; p = 0.031) while ViR was not found statistically associated (p = 0.456). CONCLUSIONS: This study confirms the safety and efficacy of the mitral ViV procedure. ViR patients appear at higher risk of procedural complications. The presence of PVL could be associated with markedly worse midterm prognosis. Whatever the intervention, procedural strategies to reduce PVL incidence remain to be assessed to prevent latter adverse outcomes.


Asunto(s)
Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Anciano de 80 o más Años , Bioprótesis/efectos adversos , Cateterismo Cardíaco/métodos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Falla de Prótesis , Sistema de Registros , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
3.
Gerontology ; 68(7): 746-754, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34903687

RESUMEN

BACKGROUND: For patients with transcatheter aortic valve replacement (TAVR), increased length of stay (LOS) is associated with increased long-term mortality. The main objective of our study was to analyze the association between geriatrics factors and the hospital LOS for older patients undergoing TAVR for severe aortic stenosis. METHODS: This retrospective single-center study included all patients aged ≥75 who underwent TAVR between January 2018 and January 2019. Hospital LOS and postoperative complications were analyzed regarding the geriatric factors recorded during a systematic preoperative, comprehensive geriatric assessment (CGA). The individualized-care plans established after the preoperative CGA were also analyzed. RESULTS: median LOS of the 196 patients included was 6 days (interquartile range: 4-8), and 29% of patients had prolonged LOS. In a multivariable analysis, the preoperative factors associated with a prolonged hospital LOS were EuroSCORE I (p value = 0.02), prior major neurocognitive disorders (p value = 0.01), femoral access (p value <0.001), all complications (p value <0.001), and discharge in a rehabilitation center (p value <0.001). One-fourth (27%) of the patients had at least 1 geriatric complication. After CGA, 69 patients did not need any geriatric recommendation, whereas for the 127 other patients, an individualized-care plan was established but only 46 (36%) of them were followed up. CONCLUSION: Our results favor the preoperative screening for major neurocognitive disorders in order to reduce LOS. Furthermore, the proposed individual-care plans after CGA were poorly followed. Practitioners may perceive the preoperative CGA as a screening tool, but its primary objective is to develop an individualized-care plan as a prehabilitation plan in order to optimize the physical, functional, and social issues.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Mortalidad Hospitalaria , Humanos , Tiempo de Internación , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
4.
J Card Surg ; 37(12): 5019-5026, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36378912

RESUMEN

BACKGROUND AND AIM: The mortality rate of patients with post-myocardial infarction (MI) ventricular septal defects (VSDs) is high, and the benefit of surgery is unclear. We aimed to investigate the management and outcomes of post-MI VSD over a 10-year period in a large cohort. METHODS: Data of patients with post-MI VSD admitted in three French university hospitals from 2008 to 2019 were examined. The characteristics of those who underwent surgery were compared with those who received medical treatment. Mortality risk factors, survival curves, and outcomes at 30 days and 1 year after treatment were determined. RESULTS: Of the 92 patients whose data were examined, 50 underwent surgery and 42 received exclusive medical treatment. All patients were critically ill. Overall, 76.1% of patients received inotropic support, and 63% received mechanical ventilation. Circulatory assistance, mainly via intra-aortic balloon pump and extra-corporeal membrane oxygenation, was provided to 46.7% patients, with 14.1% requiring a second assistance. The median time to surgery was 4 days. At 1 year, mortality was 46% in those who underwent surgery and 83.3% in those treated medically (p < .001). Survival curves at 1 and 3 months showed major differences, and the survival rate showed little change 30 days after treatment. Cardiogenic shock and cardiac arrest emerged as risk factors for mortality. CONCLUSIONS: In our retrospective, multicenter study, the mortality resulting from post-MI VSD did not seem to improve over the last decade. Although surgery carried considerable risks, it improved survival.


Asunto(s)
Defectos del Tabique Interventricular , Infarto del Miocardio , Humanos , Estudios Retrospectivos , Infarto del Miocardio/complicaciones , Infarto del Miocardio/cirugía , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia , Defectos del Tabique Interventricular/etiología , Factores de Riesgo , Resultado del Tratamiento
5.
Circulation ; 141(4): 243-259, 2020 01 28.
Artículo en Inglés | MEDLINE | ID: mdl-31736356

RESUMEN

BACKGROUND: No randomized study powered to compare balloon expandable (BE) with self expanding (SE) transcatheter heart valves (THVs) on individual end points after transcatheter aortic valve replacement has been conducted to date. METHODS: From January 2013 to December 2015, the FRANCE-TAVI nationwide registry (Registry of Aortic Valve Bioprostheses Established by Catheter) included 12 141 patients undergoing BE-THV (Edwards, n=8038) or SE-THV (Medtronic, n=4103) for treatment of native aortic stenosis. Long term mortality status was available in all patients (median 20 months; interquartile range, 14 to 30). Patients treated with BE-THV (n=3910) were successfully matched 1:1 with 3910 patients treated with SE-THV by using propensity score (25 clinical, anatomical, and procedural variables) and by date of the procedure (within 3 months). The first coprimary outcome was ≥ moderate occurrence of paravalvular regurgitation or in-hospital mortality, or both. The second coprimary outcome was 2-year all-cause mortality. RESULTS: In propensity-matched analyses, the incidence of the first coprimary outcome was higher with SE-THV (19.8%) compared with BE-THV (11.9%; relative risk, 1.68 [95% CI, 1.46-1.91]; P<0.0001). Each component of the outcome was also higher in patients receiving SE-THV: ≥ moderate paravalvular regurgitation (15.5% versus 8.3%; relative risk, 1.90 [95% CI, 1.63-2.22]; P<0.0001) and in hospital mortality (5.6% versus 4.2%; relative risk, 1.34 [95% CI, 1.07-1.66]; P=0.01). During follow up, all cause mortality occurred in 899 patients treated with SE-THV (2-year mortality, 29.8%) and in 801 patients treated with BE-THV (2-year mortality, 26.6%; hazard ratio, 1.17 [95% CI, 1.06-1.29]; P=0.003). Similar results were found using inverse probability of treatment weighting using propensity score analysis. CONCLUSION: The present study suggests that use of SE-THV was associated with a higher risk of paravalvular regurgitation and higher in-hospital and 2-year mortality compared with use of BE-THV. These data strongly support the need for a randomized trial sufficiently powered to compare the latest generation of SE-THV and BE-THV. CLINICAL TRIAL REGISTRATION: https://www.clinicaltrials.gov. Unique identifier: NCT01777828.


Asunto(s)
Prótesis Valvulares Cardíacas , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Supervivencia sin Enfermedad , Femenino , Estudios de Seguimiento , Francia/epidemiología , Humanos , Masculino , Tasa de Supervivencia
6.
Catheter Cardiovasc Interv ; 98(1): E9-E17, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-32966675

RESUMEN

BACKGROUND: Bifurcation lesions in coronary arteries are complex to treat with coronary stents, which are not designed for that purpose and can be unproperly deployed. Moreover, devices are constantly evolving, and so are angioplasty techniques. OBJECTIVES: The aim of this study was to determine the performances of different stents in the treatment of bifurcation lesions using the re-proximal optimization technique (rePOT). METHODS: Eleven stent platforms were evaluated: Xience Sierra (Abbott), Xience Alpine (Abbott), Synergy (Boston), Coroflex Isar (Bbraun), Cobra PzF (Celonova), Ultimaster (Terumo), Resolute Integrity (Medtronic), Resolute Onyx (Medtronic), Optimax (Hexacath), Orsiro (Biotronik), and Absorb (Abbott). Stents were deployed in a silicone fractal bifurcation model using the rePOT. Micro-computed tomography was performed to assess side branch ostium coverage and strut malapposition, as well as the effect of rePOT on stent cell area. RESULTS: Our study showed significant differences between stent platforms regarding side branch ostium coverage (p = .002). The Synergy and Cobra PzF stents were the most performant devices to avoid ostium coverage. Strut malapposition varied significantly between devices (p = .008) but the percentage of malapposed struts was relatively low. Significant differences were observed between stents regarding the cell area before (p = .002) and also after rePOT (p = .003), and the increase in cell area caused by rePOT varied considerably between devices (p = .08). CONCLUSION: This study highlighted significant differences in the performances of stent platforms deployed in a fractal bifurcation model using rePOT, with a variable impact of the procedure on stent cell area.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Fractales , Humanos , Diseño de Prótesis , Tomografía de Coherencia Óptica , Resultado del Tratamiento , Microtomografía por Rayos X
7.
Catheter Cardiovasc Interv ; 98(2): 352-362, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-33615701

RESUMEN

OBJECTIVES: To evaluate the effectiveness of anticoagulant therapies in patients with clinical transcatheter heart valve (THV) thrombosis, to describe complications, and to assess their risk profile was the objectives. BACKGROUND: Little research has been conducted on clinical THV thrombosis. METHODS: Patients with clinical THV thrombosis were identified based on greater than 50% increased transvalvular gradient on transthoracic echocardiogram confirmed by 4-dimensional computed tomography, transesophageal echocardiogram, or regression with anticoagulant therapy. A cohort free from thrombosis for more than 1,100 days postprocedure was used for comparison. RESULTS: Fifty-four patients with clinical THV thrombosis were identified. Most subjects (98.1%) received anticoagulant therapy which was effective (≥50% reduction in transvalvular gradient or return to postprocedure value) in 96%. The rate of serious hemodynamic or embolic complications in the thrombosis population was 31.5%. A multivariate analysis of subjects with and without thrombosis indicated a significantly increased risk of thrombosis from preexisting thrombocytopenia (odds ratio [OR] 9.96), absence of predilatation (OR = 5.67), renal insufficiency (OR = 4.84), and >10 mmHg mean transvalvular gradient postprocedure (OR = 3.36). No recurrence of thrombosis was identified during on average 685 days follow-up. CONCLUSIONS: These data, from one of the largest cohorts with clinical THV thrombosis confirm anticoagulants appear effective. The rate of serious associated complications was high. The findings underline the importance of recognizing risk factors for thrombosis.


Asunto(s)
Estenosis de la Válvula Aórtica , Trombosis Coronaria , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estudios de Cohortes , Humanos , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
8.
Circulation ; 138(23): 2597-2607, 2018 12 04.
Artículo en Inglés | MEDLINE | ID: mdl-30571260

RESUMEN

BACKGROUND: The FRANCE-2 registry (French Aortic National Corevalve and Edwards) previously reported good early- and medium-term clinical and echocardiographic efficacy for transcatheter aortic valve replacement. We here report 5-year follow-up results from the registry. METHODS: The registry includes all consecutive patients undergoing transcatheter aortic valve replacement for severe aortic stenosis in France. Follow-up is scheduled at 30 days, 6 months, then annually from 1 to 5 years. Clinical events were defined according to the Valve Academic Research Consortium criteria, and hemodynamic structural valve deterioration (SVD) was defined according to the consensus statement by the European Association of Percutaneous Cardiovascular Interventions. RESULTS: Between January 2010 and January 2012, 4201 patients were enrolled in 34 centers. Five-year vital status was available for 95.5% of patients; 88.1% had clinical evaluation or died. Overall, at 5 years, all-cause mortality was 60.8% (n=2478; 95% CI, 59.3% to 62.3%). The majority of cardiovascular events occurred in the first month after valve implantation, and incidence remained low thereafter, at <2% per year up to 5 years, except for heart failure. The rate of heart failure was 14.3% at 1 year, then decreased over time to <5% per year. In cumulative incidence function, the rates of severe SVD and moderate/severe SVD at 5 years were 2.5% and 13.3%, respectively. Mortality did not differ between patients with or without severe SVD (hazard ratio, 0.71; 95% CI, 0.47-1.07; P=0.1). Finally, in the population of patients with severe SVD, 1 patient (1.7%) experienced a stroke, and 8 patients presented ≥1 heart failure event (13.3%). CONCLUSIONS: The 5-year follow-up results of the FRANCE-2 registry represent the largest long-term data set available in a high-risk population. In surviving patients, the low rate of clinical events and the low level of SVD after 1 year support the long-term efficacy of transcatheter aortic valve replacement in both types of transcatheter prosthesis featuring in the registry.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Falla de Equipo , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/epidemiología , Hemodinámica , Humanos , Masculino , Modelos de Riesgos Proporcionales , Sistema de Registros , Factores de Riesgo , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Análisis de Supervivencia , Factores de Tiempo , Resultado del Tratamiento
11.
Cardiovasc Eng Technol ; 15(4): 443-450, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38468115

RESUMEN

PURPOSE: Pre-stenting of the right ventricular outflow tract (RVOT) is commonly performed before percutaneous pulmonary valve implantation (PPVI), to relieve obstruction, prevent valved stent fractures, and provide a landing zone. This study aimed to evaluate the biomechanical characteristics of the stents currently used to perform pre-stenting of the RVOT. METHODS: We assessed five commercially available stents: Cheatham-Platinum Stent ("CP Stent"), AndraStent XL, AndraStent XXL, Optimus XL, and Optimus XXL. Following stent deployment at nominal pressure, radial and longitudinal elastic recoils and radial resistance were measured. The bending stiffness of the stents crimped onto the balloons was also evaluated. RESULTS: Three samples were tested for each stent. Our study showed no significant difference between the stent platforms in terms of radial elastic recoil, which was relatively low (< 10%). The longitudinal elastic recoil was also low for all the devices (< 5%). Significant differences were observed in radial resistance (P < 0.001). CP Stent and AndraStent XL exhibited the highest radial resistances. The bending stiffnesses of the stents crimped on their balloons were significantly different (P < 0.00001). Optimus XL and XXL were more flexible than the other stents. CONCLUSION: This study highlights the significant differences between the stents currently used in RVOT pre-stenting. Stents with good radial resistance are preferred, especially for calcified vessels, and flexibility is crucial for tortuous vessels. We proposed an algorithm for selecting the most suitable stent according to the need for radial force and flexibility, which will help inform clinicians considering RVOT revalvulation.


Asunto(s)
Ensayo de Materiales , Diseño de Prótesis , Stents , Fenómenos Biomecánicos , Humanos , Obstrucción del Flujo Ventricular Externo/fisiopatología , Obstrucción del Flujo Ventricular Externo/cirugía , Elasticidad , Válvula Pulmonar/cirugía , Válvula Pulmonar/fisiopatología , Válvula Pulmonar/diagnóstico por imagen , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estrés Mecánico , Cateterismo Cardíaco/instrumentación
12.
Can J Cardiol ; 40(1): 31-39, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37660934

RESUMEN

BACKGROUND: There are dated and conflicting data about the optimal timing of initiation of P2Y12 inhibitors in elective percutaneous coronary intervention (PCI). Peri-PCI myocardial necrosis is associated with poor outcomes. We aimed to assess the impact of the P2Y12 inhibitor loading time on periprocedural myocardial necrosis in the population of the randomized Assessment of Loading With the P2Y12 Inhibitor Ticagrelor or Clopidogrel to Halt Ischemic Events in Patients Undergoing Elective Coronary Stenting (ALPHEUS) trial, which compared ticagrelor with clopidogrel in high-risk patients who received elective PCI. METHODS: The ALPHEUS trial divided 1809 patients into quartiles of loading time. The ALPHEUS primary outcome was used (type 4 [a or b] myocardial infarction or major myocardial injury) as well as the main secondary outcome (type 4 [a or b] myocardial infarction or any type of myocardial injury). RESULTS: Patients in the first quartile group (Q1) presented higher rates of the primary outcome (P = 0.01). When compared with Q1, incidences of the primary outcome decreased in patients with longer loading times (adjusted odds ratio [adjOR], 0.70 [0.52.-0.95]; P = 0.02 for Q2; adjOR 0.65 [0.48-0.88]; P < 0.01 for Q3; adjOR 0.66 [0.49-0.89]; P < 0.01 for Q4). Concordant results were found for the main secondary outcome. There was no interaction with the study drug allocated by randomization (clopidogrel or ticagrelor). Bleeding complications (any bleeding ranging between 4.9% and 7.3% and only 1 major bleeding at 48 hours) and clinical ischemic events were rare and did not differ among groups. CONCLUSIONS: In elective PCI, administration of the oral P2Y12 inhibitor at the time of PCI could be associated with more frequent periprocedural myocardial necrosis than an earlier administration. The long-term clinical consequences remain unknown.


Asunto(s)
Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Clopidogrel/uso terapéutico , Ticagrelor/uso terapéutico , Antagonistas del Receptor Purinérgico P2Y/uso terapéutico , Intervención Coronaria Percutánea/métodos , Infarto del Miocardio/etiología , Inhibidores de Agregación Plaquetaria/uso terapéutico , Resultado del Tratamiento
13.
EuroIntervention ; 20(17): e1076-e1085, 2024 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-39219361

RESUMEN

BACKGROUND: Large datasets of transcatheter aortic valve implantation (TAVI) for pure aortic valve regurgitation (PAVR) are scarce. AIMS: We aimed to report procedural safety and long-term clinical events (CE) in a contemporary cohort of PAVR patients treated with new-generation devices (NGD). METHODS: Patients with grade III/IV PAVR enrolled in the FRANCE-TAVI Registry were selected. The primary safety endpoint was technical success (TS) according to Valve Academic Research Consortium 3 criteria. The co-primary endpoint was defined as a composite of mortality, heart failure hospitalisation and valve reintervention at last follow-up. RESULTS: From 2015 to 2021, 227 individuals (64.3% males, median age 81.0 [interquartile range {IQR} 73.5-85.0] years, with EuroSCORE II 6.0% [IQR 4.0-10.9]) from 41 centres underwent TAVI with NGD, using either self-expanding (55.1%) or balloon-expandable valves (44.9%; p=0.50). TS was 85.5%, with a non-significant trend towards increased TS in high-volume activity centres. A second valve implantation (SVI) was needed in 8.8% of patients, independent of valve type (p=0.82). Device size was ≥29 mm in 73.0% of patients, post-procedure grade ≥III residual aortic regurgitation was rare (1.2%), and the permanent pacemaker implantation (PPI) rate was 36.0%. At 30 days, the incidences of mortality and reintervention were 8.4% and 3.5%, respectively. The co-primary endpoint reached 41.6% (IQR 34.4-49.6) at 1 year, increased up to 61.8% (IQR 52.4-71.2) at 4 years, and was independently predicted by TS, with a hazard ratio of 0.45 (95% confidence interval: 0.27-0.76); p=0.003. CONCLUSIONS: TAVI with NGD in PAVR patients is efficient and reasonably safe. Preventing the need for an SVI embodies the major technical challenge. Larger implanted valves may have limited this complication, outweighing the increased risk of PPI. Despite successful TAVI, PAVR patients experience frequent CE at long-term follow-up.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Insuficiencia de la Válvula Aórtica/cirugía , Masculino , Femenino , Anciano , Anciano de 80 o más Años , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Factores de Riesgo , Francia
14.
Diagn Interv Imaging ; 2023 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-37331824

RESUMEN

PURPOSE: The purpose of this study was to evaluate the percentage of coronary angiography that can be securely avoided by the interpretation of coronary arteries on pre transcatheter aortic valve implantation CT (TAVI-CT), using CT images obtained with deep-learning reconstruction and motion correction algorithms. MATERIAL AND METHOD: All consecutive patients who underwent TAVI-CT and coronary angiography, from December 2021 to July 2022 were screened for inclusion in the study. Patients who had previous coronary artery revascularization or who did not undergo TAVI were excluded. All TAVI-CT examinations were obtained using deep-learning reconstruction and motion correction algorithms. On TAVI-CT examinations, quality and stenosis of coronary artery were analyzed retrospectively. When insufficient image quality and/or when diagnosis or doubt of one significant coronary artery stenosis, patients were considered as having possible coronary artery stenosis. The results of coronary angiography were used as the standard of reference for significant CAS. RESULTS: A total of 206 patients (92 men; mean age, 80.6 years) were included; of these 27/206 (13%) had significant coronary artery stenosis on coronary angiography and were referred for potential revascularization. Sensitivity, specificity, negative predictive value, positive predictive value, and accuracy of TAVI-CT to identify patients requiring coronary artery revascularization was 100% (95% confidence interval [CI]: 87.2-100%), 100% (95% CI: 96.3-100%), 54% (95% CI: 46.6-61.6), 25% (95% CI: 17.0-34.0%) and 60% (95% CI: 53.1-66.9%) respectively. Intra- and inter observer variability was substantial agreement for quality and decision to recommend coronary angiography. Mean reading time was 2 ± 1.2 (standard deviation) min (range: 1-5 min). Overall, TAVI-CT could potentially rule out indication for revascularization for 97 patients (47%). CONCLUSION: Analysis of coronary artery on TAVI-CT using deep-learning reconstruction and motion correction algorithms can potentially safely avoid coronary angiography in 47% of patients.

15.
Eur Heart J Open ; 2(3): oeac029, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35919341

RESUMEN

Aims: After transcatheter aortic valve replacement (TAVR), cardiovascular and non-cardiovascular comorbidities may offset the survival benefit from the procedure. We aimed to describe the relationships between that benefit and patient comorbidities. Methods and results: The study pooled two European cohorts of patients with severe aortic stenosis (AS-pooled): one with patients who underwent (cohort of AS patients treated by TAVR, N = 233) and another with patients who did not undergo TAVR (cohort of AS patients treated medically; N = 291). The investigators collected the following: calcification prognostic impact (CAPRI) and Charlson scores for cardiovascular and non-cardiovascular comorbidities, activities of daily living (ADL)/instrumental activities of daily living (IADL) scores for frailty as well as routine Society of Thoracic Surgeons (STS) score and Logistic Euroscore. Unlike ADL/IADL scores, CAPRI and Charlson scores were found to be independent predictors of 1-year all-cause death in the AS-pooled cohort, with and without adjustment for STS score or Logistic Euroscore; they were thus retained to define a three-level prognostic scale (good, intermediate, and poor). The survival benefit from TAVR-vs. no TAVR-was stratified according to these three prognosis categories. The beneficial effect of TAVR on 1-year all-cause death was significant in patients with good and intermediate prognosis, hazard ratio (95% confidence interval): 0.36 (0.18; 0.72) and 0.32 (0.15; 0.67). That effect was reduced and not statistically significant in patient with poor prognosis [0.65 (0.22; 1.88)]. Conclusion: The study showed that, beyond a given comorbidity burden (as assessed by CAPRI and Charlson scores), the probability of death within a year was high and poorly reduced by TAVR. This indicates the futility of TAVR in patients in the poor prognosis category.

16.
Clin Interv Aging ; 16: 1285-1292, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34262268

RESUMEN

BACKGROUND: Transcatheter aortic-valve replacement (TAVR) reduces mortality and improves quality of life in patients with severe aortic valve stenosis. One third of patients have no benefit one year after TAVR. Sarcopenia, an age-related loss of skeletal muscle mass, is associated with increased physical disability and mortality. The main purpose was to evaluate the impact of severe sarcopenia on rehospitalization one year after TAVR in older patients. METHODS: All patients aged ≥75 referred for a TAVR in 2018 were included. Severe sarcopenia was defined by a loss of skeletal muscle mass defined on CT-scan measurement associated with a gait speed ≤0.8m/s. The main outcome was rehospitalization one year after TAVR. RESULTS: Median age of the 182 included patients was 84, and 35% had an unplanned hospitalization at one year. Severe sarcopenia was diagnosed in 9 patients (4.9%). Univariable analysis showed that gait speed was a factor associated with readmission [HR=0.32, 95% CI (0.10-0.97), p=0.04] but not severe sarcopenia. In multivariable analysis, only diabetes was significantly associated with rehospitalization [HR=2.06, 95% CI (1.11-3.84), p=0.02]. Prevalence of severe sarcopenia varied according to different thresholds of skeletal muscle mass on CT-scan. CONCLUSION: Even though severe sarcopenia was not correlated with rehospitalization and mortality at one year after TAVR, our results emphasize the changes in the prevalence according to cutoff used. It highlights the need to define standardized methods and international threshold for sarcopenia diagnosis by CT-scan measurements, in general population and for patients with valvular heart disease.


Asunto(s)
Estenosis de la Válvula Aórtica , Músculo Esquelético/diagnóstico por imagen , Calidad de Vida , Sarcopenia , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Velocidad al Caminar , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/psicología , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Efectos Adversos a Largo Plazo/mortalidad , Efectos Adversos a Largo Plazo/terapia , Masculino , Readmisión del Paciente/estadística & datos numéricos , Medición de Riesgo , Factores de Riesgo , Sarcopenia/epidemiología , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X/métodos
17.
JACC Case Rep ; 3(1): 64-68, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34317470

RESUMEN

Transcatheter aortic valve replacement is currently used off-label for noncalcified aortic valve regurgitation and therefore is restricted to selected cases. In this setting we describe a rare complication of Sapien 3 (Edwards Lifesciences, Irvine, California) embolization from the left ventricle to the descending aorta. Given their technical challenges, such procedures require specific considerations and management. (Level of Difficulty: Advanced.).

18.
Eur J Cardiothorac Surg ; 60(4): 874-879, 2021 10 22.
Artículo en Inglés | MEDLINE | ID: mdl-33724380

RESUMEN

OBJECTIVES: The carotid approach for transcatheter aortic valve replacement (TAVR) has been shown to be feasible and safe. The goal of this study was to compare the 30-day outcomes of trans-carotid (TC) and transfemoral (TF) TAVR. METHODS: This retrospective study enrolled 500 consecutive patients treated by TC-TAVR (n = 100) or TF-TAVR (n = 400) with percutaneous closure between January 2018 and January 2020 at the Nantes University Hospital. The primary end-point was the occurrence of cardiovascular death and cerebrovascular events at 30 days. RESULTS: The mean age was 79.9 ± 8.1 in the TC group and 81.3 ± 6.9 (P = 0.069) in the TF group. The TC group had more men (69% vs 50.5%; P = 0.001) and more patients with peripheral vascular disease (86% vs 14.8%; P < 0.0001). Cardiac characteristics were similar between the groups, and the EuroSCORE II was 3.8 ± 2.6% vs 4.6 ± 6.0%, respectively (P = 0.443). The 30-day mortality was 2% in the TC group versus 1% in the TF group (P = 0.345). TC-TAVR was not associated with an increased risk of stroke (2% vs 2.5%; P = 0.999) or major vascular complications (2% vs 4%; P = 0.548). More permanent pacemakers were implanted in the TF group (14.9% vs 5.6%; P = 0.015), and no moderate or severe aortic regurgitation was observed in the TC group (0 vs 3.3%; P = 0.08). TC-TAVR was not associated with an increased risk of mortality or stroke at 30 days (odds ratio 1.32; 95% confidence interval 0.42-4.21; P = 0.63) in the multivariable analysis. CONCLUSIONS: No statistically significant differences between TC-TAVR and TF-TAVR were observed; therefore, TC-TAVR should be the first alternative in patients with anatomical contraindications to the femoral route.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Arteria Femoral/cirugía , Humanos , Masculino , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
19.
Am J Cardiol ; 144: 118-124, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-33383007

RESUMEN

Patients with symptomatic aortic stenosis are often treated with a surgical valve replacement. Surgical bioprosthetic valves degenerate over time and therefore may necessitate a redo surgery. This analysis reports the 2-year clinical outcomes of the Valve-in-Valve study, which evaluated transcatheter aortic valve implantation using the CoreValve and Evolut R devices in patients with degenerated surgical aortic bioprostheses at high risk for surgery. The prospective Valve-in-Valve study enrolled 202 eligible patients with failing surgical aortic bioprostheses due to stenosis, regurgitation, or a combination of both. The Evolut R bioprosthesis was used in 90.5% of valve-in-valve transcatheter aortic valve implantation cases. Two-year all-cause and cardiovascular mortality rates were 16.5% and 11.1%, respectively. Other clinical events included stroke (7.9%), disabling stroke (1.7%), and new pacemaker implantation (10.1%). The 2-year all-cause mortality rate was significantly higher in patients with discharge mean gradients ≥20 mmHg vs. those with lower mean gradients (21.0% vs 7.6%, p = 0.025). Discharge mean gradients ≥20 mm Hg were associated with smaller surgical bioprostheses (OR, 7.2 [95% CI 2.3 to 22.1]. In patients with failing surgical aortic bioprostheses, valve-in-valve treatment using a supra-annular self-expanding bioprosthesis provides significant functional improvements with acceptable rates of complications, especially if a postprocedural mean gradient of <20 mmHg can be achieved.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Vigilancia de Productos Comercializados , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Reoperación , Reemplazo de la Válvula Aórtica Transcatéter/métodos
20.
Ann Thorac Surg ; 112(3): 763-769, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33227273

RESUMEN

BACKGROUND: For older patients undergoing cardiac surgery, geriatric factors are known to increase postoperative complications and prolong length of stay (LOS). Comprehensive geriatric assessment (CGA) is an evidence-based method for geriatric evaluation to develop an individualized-care plan to optimize physical, functional, and social issues. This study analyzed the association between preoperative CGA and hospital LOS after combined cardiac surgery. METHODS: This retrospective monocentric study included all patients aged 75 years and greater who underwent combined cardiac surgery between 2014 and 2017. Hospital LOS, intensive care unit LOS, and postoperative complications were compared between patients with or without preoperative CGA before and after propensity-score matching. RESULTS: Mean age of the 407 patients was 79.6 years; 114 underwent a preoperative CGA (28%). For 305 patients (74.9%), coronary artery bypass was associated with aortic valve replacement. After propensity-score matching, a significant difference was found between the 2 groups (preoperative CGA versus none) for in-hospital LOS (12 versus 13 days; P = .04) and intensive care unit LOS (3 versus 4 days; P = .01). In multivariable analysis, a significant association remained between hospital LOS and CGA (P = .02), renal function (P = .02), mitral replacement (P = .001), and complications (P = .001). CONCLUSIONS: Our results favor the use of systematic preoperative CGA. These encouraging results need to be validated by prospective studies that assess the impact of individualized-care plan established after CGA on postoperative outcomes. With an aging population, efforts are required to determine how to implement preoperative individualized-care plans to improve postoperative outcomes for vulnerable patients undergoing cardiac surgery.


Asunto(s)
Evaluación Geriátrica , Tiempo de Internación , Anciano , Anciano de 80 o más Años , Procedimientos Quirúrgicos Cardíacos/métodos , Femenino , Humanos , Masculino , Periodo Preoperatorio , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA