1.
J Endourol ; 21(9): 985-92, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17941773

RESUMEN

BACKGROUND AND PURPOSE: The effects of commonly used reprocessing methods on flexible ureteroscope longevity have never been examined. We prospectively studied the effects of Steris 1 sterilization and Cidex ortho-phthalaldehyde (OPA) high-level disinfection (HLD) on the image quality, physical structure, and deflective properties of two new flexible ureteroscopes. MATERIALS AND METHODS: Two identical "out-of-the-box" Storz 11278AU1 flexible ureteroscopes (Karl Storz Endoscopy, Tuttlingen, Germany) were sterilized individually using the Steris 1 system (Steris Mentor, Ohio) or disinfected with Cidex OPA (Advanced Sterilization Products, J&J, Irvine, CA) for 100 trials followed by a crossover to the other method for another 100 trials over a period of 1 year. After every five trials, optical quality, angle of deflection, and fiber damage were analyzed in the laboratory. Throughout the study, neither of these ureteroscopes was used clinically. RESULTS: After 100 trials, ureteroscope 1, which was sterilized initially in the Steris system, had a 12-mm tear on its shaft (noted after the 17th trial), 297 damaged fibers, and a 37% drop in resolution (loss of 3.75 lines/mm). There was no change in deflection from baseline. In contrast, after 100 cycles, ureteroscope 2, which was subjected to HLD with Cidex OPA, had no visible external damage, a 0% change in resolution, 10 damaged fibers, and no change in deflection. After the crossover, ureteroscope 2 developed a semilunar defect that obscured the endoscopic view, whereas there was no further significant damage to ureteroscope 1. CONCLUSION: After 100 cycles, the Steris 1 system rendered the flexible ureteroscope unusable, whereas HLD with Cidex OPA had minimal adverse impact.


Asunto(s)
Desinfectantes/farmacología , Desinfección/métodos , Ureteroscopios , o-Ftalaldehído/farmacología , Estudios Cruzados , Diagnóstico por Imagen/métodos , Endoscopios , Endoscopía/métodos , Contaminación de Equipos/prevención & control , Diseño de Equipo , Falla de Equipo , Equipo Reutilizado , Tecnología de Fibra Óptica , Humanos , Estudios Prospectivos , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA