Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Lancet Oncol ; 25(5): 603-613, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38588682

RESUMEN

BACKGROUND: Patients with stage II-III HER2-positive breast cancer have good outcomes with the combination of neoadjuvant chemotherapy and HER2-targeted agents. Although increasing the number of chemotherapy cycles improves pathological complete response rates, early complete responses are common. We investigated whether the duration of chemotherapy could be tailored on the basis of radiological response. METHODS: TRAIN-3 is a single-arm, phase 2 study in 43 hospitals in the Netherlands. Patients with stage II-III HER2-positive breast cancer aged 18 years or older and a WHO performance status of 0 or 1 were enrolled. Patients received neoadjuvant chemotherapy consisting of paclitaxel (80 mg/m2 of body surface area on day 1 and 8 of each 21 day cycle), trastuzumab (loading dose on day 1 of cycle 1 of 8 mg/kg bodyweight, and then 6 mg/kg on day 1 on all subsequent cycles), and carboplatin (area under the concentration time curve 6 mg/mL per min on day 1 of each 3 week cycle) and pertuzumab (loading dose on day 1 of cycle 1 of 840 mg, and then 420 mg on day 1 of each subsequent cycle), all given intravenously. The response was monitored by breast MRI every three cycles and lymph node biopsy. Patients underwent surgery when a complete radiological response was observed or after a maximum of nine cycles of treatment. The primary endpoint was event-free survival at 3 years; however, follow-up for the primary endpoint is ongoing. Here, we present the radiological and pathological response rates (secondary endpoints) of all patients who underwent surgery and the toxicity data for all patients who received at least one cycle of treatment. Analyses were done in hormone receptor-positive and hormone receptor-negative patients separately. This trial is registered with ClinicalTrials.gov, number NCT03820063, recruitment is closed, and the follow-up for the primary endpoint is ongoing. FINDINGS: Between April 1, 2019, and May 12, 2021, 235 patients with hormone receptor-negative cancer and 232 with hormone receptor-positive cancer were enrolled. Median follow-up was 26·4 months (IQR 22·9-32·9) for patients who were hormone receptor-negative and 31·6 months (25·6-35·7) for patients who were hormone receptor-positive. Overall, the median age was 51 years (IQR 43-59). In 233 patients with hormone receptor-negative tumours, radiological complete response was seen in 84 (36%; 95% CI 30-43) patients after one to three cycles, 140 (60%; 53-66) patients after one to six cycles, and 169 (73%; 66-78) patients after one to nine cycles. In 232 patients with hormone receptor-positive tumours, radiological complete response was seen in 68 (29%; 24-36) patients after one to three cycles, 118 (51%; 44-57) patients after one to six cycles, and 138 (59%; 53-66) patients after one to nine cycles. Among patients with a radiological complete response after one to nine cycles, a pathological complete response was seen in 147 (87%; 95% CI 81-92) of 169 patients with hormone receptor-negative tumours and was seen in 73 (53%; 44-61) of 138 patients with hormone receptor-positive tumours. The most common grade 3-4 adverse events were neutropenia (175 [37%] of 467), anaemia (75 [16%]), and diarrhoea (57 [12%]). No treatment-related deaths were reported. INTERPRETATION: In our study, a third of patients with stage II-III hormone receptor-negative and HER2-positive breast cancer had a complete pathological response after only three cycles of neoadjuvant systemic therapy. A complete response on breast MRI could help identify early complete responders in patients who had hormone receptor negative tumours. An imaging-based strategy might limit the duration of chemotherapy in these patients, reduce side-effects, and maintain quality of life if confirmed by the analysis of the 3-year event-free survival primary endpoint. Better monitoring tools are needed for patients with hormone receptor-positive and HER2-positive breast cancer. FUNDING: Roche Netherlands.


Asunto(s)
Anticuerpos Monoclonales Humanizados , Protocolos de Quimioterapia Combinada Antineoplásica , Neoplasias de la Mama , Imagen por Resonancia Magnética , Terapia Neoadyuvante , Estadificación de Neoplasias , Paclitaxel , Receptor ErbB-2 , Humanos , Neoplasias de la Mama/tratamiento farmacológico , Neoplasias de la Mama/patología , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Persona de Mediana Edad , Receptor ErbB-2/metabolismo , Receptor ErbB-2/análisis , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Adulto , Anciano , Paclitaxel/administración & dosificación , Trastuzumab/administración & dosificación , Carboplatino/administración & dosificación , Quimioterapia Adyuvante , Países Bajos , Esquema de Medicación
2.
Radiology ; 311(1): e232133, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38687216

RESUMEN

Background The performance of publicly available large language models (LLMs) remains unclear for complex clinical tasks. Purpose To evaluate the agreement between human readers and LLMs for Breast Imaging Reporting and Data System (BI-RADS) categories assigned based on breast imaging reports written in three languages and to assess the impact of discordant category assignments on clinical management. Materials and Methods This retrospective study included reports for women who underwent MRI, mammography, and/or US for breast cancer screening or diagnostic purposes at three referral centers. Reports with findings categorized as BI-RADS 1-5 and written in Italian, English, or Dutch were collected between January 2000 and October 2023. Board-certified breast radiologists and the LLMs GPT-3.5 and GPT-4 (OpenAI) and Bard, now called Gemini (Google), assigned BI-RADS categories using only the findings described by the original radiologists. Agreement between human readers and LLMs for BI-RADS categories was assessed using the Gwet agreement coefficient (AC1 value). Frequencies were calculated for changes in BI-RADS category assignments that would affect clinical management (ie, BI-RADS 0 vs BI-RADS 1 or 2 vs BI-RADS 3 vs BI-RADS 4 or 5) and compared using the McNemar test. Results Across 2400 reports, agreement between the original and reviewing radiologists was almost perfect (AC1 = 0.91), while agreement between the original radiologists and GPT-4, GPT-3.5, and Bard was moderate (AC1 = 0.52, 0.48, and 0.42, respectively). Across human readers and LLMs, differences were observed in the frequency of BI-RADS category upgrades or downgrades that would result in changed clinical management (118 of 2400 [4.9%] for human readers, 611 of 2400 [25.5%] for Bard, 573 of 2400 [23.9%] for GPT-3.5, and 435 of 2400 [18.1%] for GPT-4; P < .001) and that would negatively impact clinical management (37 of 2400 [1.5%] for human readers, 435 of 2400 [18.1%] for Bard, 344 of 2400 [14.3%] for GPT-3.5, and 255 of 2400 [10.6%] for GPT-4; P < .001). Conclusion LLMs achieved moderate agreement with human reader-assigned BI-RADS categories across reports written in three languages but also yielded a high percentage of discordant BI-RADS categories that would negatively impact clinical management. © RSNA, 2024 Supplemental material is available for this article.


Asunto(s)
Neoplasias de la Mama , Adulto , Anciano , Femenino , Humanos , Persona de Mediana Edad , Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico por imagen , Lenguaje , Imagen por Resonancia Magnética/métodos , Mamografía/métodos , Sistemas de Información Radiológica/estadística & datos numéricos , Estudios Retrospectivos , Ultrasonografía Mamaria/métodos
3.
Eur J Nucl Med Mol Imaging ; 51(9): 2706-2732, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38740576

RESUMEN

INTRODUCTION: There is much literature about the role of 2-[18F]FDG PET/CT in patients with breast cancer (BC). However, there exists no international guideline with involvement of the nuclear medicine societies about this subject. PURPOSE: To provide an organized, international, state-of-the-art, and multidisciplinary guideline, led by experts of two nuclear medicine societies (EANM and SNMMI) and representation of important societies in the field of BC (ACR, ESSO, ESTRO, EUSOBI/ESR, and EUSOMA). METHODS: Literature review and expert discussion were performed with the aim of collecting updated information regarding the role of 2-[18F]FDG PET/CT in patients with no special type (NST) BC and summarizing its indications according to scientific evidence. Recommendations were scored according to the National Institute for Health and Care Excellence (NICE) criteria. RESULTS: Quantitative PET features (SUV, MTV, TLG) are valuable prognostic parameters. In baseline staging, 2-[18F]FDG PET/CT plays a role from stage IIB through stage IV. When assessing response to therapy, 2-[18F]FDG PET/CT should be performed on certified scanners, and reported either according to PERCIST, EORTC PET, or EANM immunotherapy response criteria, as appropriate. 2-[18F]FDG PET/CT may be useful to assess early metabolic response, particularly in non-metastatic triple-negative and HER2+ tumours. 2-[18F]FDG PET/CT is useful to detect the site and extent of recurrence when conventional imaging methods are equivocal and when there is clinical and/or laboratorial suspicion of relapse. Recent developments are promising. CONCLUSION: 2-[18F]FDG PET/CT is extremely useful in BC management, as supported by extensive evidence of its utility compared to other imaging modalities in several clinical scenarios.


Asunto(s)
Neoplasias de la Mama , Fluorodesoxiglucosa F18 , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía Computarizada por Tomografía de Emisión de Positrones/normas , Humanos , Neoplasias de la Mama/diagnóstico por imagen , Medicina Nuclear , Femenino , Sociedades Médicas
4.
J Magn Reson Imaging ; 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38581127

RESUMEN

In breast imaging, there is an unrelenting increase in the demand for breast imaging services, partly explained by continuous expanding imaging indications in breast diagnosis and treatment. As the human workforce providing these services is not growing at the same rate, the implementation of artificial intelligence (AI) in breast imaging has gained significant momentum to maximize workflow efficiency and increase productivity while concurrently improving diagnostic accuracy and patient outcomes. Thus far, the implementation of AI in breast imaging is at the most advanced stage with mammography and digital breast tomosynthesis techniques, followed by ultrasound, whereas the implementation of AI in breast magnetic resonance imaging (MRI) is not moving along as rapidly due to the complexity of MRI examinations and fewer available dataset. Nevertheless, there is persisting interest in AI-enhanced breast MRI applications, even as the use of and indications of breast MRI continue to expand. This review presents an overview of the basic concepts of AI imaging analysis and subsequently reviews the use cases for AI-enhanced MRI interpretation, that is, breast MRI triaging and lesion detection, lesion classification, prediction of treatment response, risk assessment, and image quality. Finally, it provides an outlook on the barriers and facilitators for the adoption of AI in breast MRI. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 6.

5.
Eur Radiol ; 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38656711

RESUMEN

Breast cancer is the most frequently diagnosed cancer in women accounting for about 30% of all new cancer cases and the incidence is constantly increasing. Implementation of mammographic screening has contributed to a reduction in breast cancer mortality of at least 20% over the last 30 years. Screening programs usually include all women irrespective of their risk of developing breast cancer and with age being the only determining factor. This approach has some recognized limitations, including underdiagnosis, false positive cases, and overdiagnosis. Indeed, breast cancer remains a major cause of cancer-related deaths in women undergoing cancer screening. Supplemental imaging modalities, including digital breast tomosynthesis, ultrasound, breast MRI, and, more recently, contrast-enhanced mammography, are available and have already shown potential to further increase the diagnostic performances. Use of breast MRI is recommended in high-risk women and women with extremely dense breasts. Artificial intelligence has also shown promising results to support risk categorization and interval cancer reduction. The implementation of a risk-stratified approach instead of a "one-size-fits-all" approach may help to improve the benefit-to-harm ratio as well as the cost-effectiveness of breast cancer screening. KEY POINTS: Regular mammography should still be considered the mainstay of the breast cancer screening. High-risk women and women with extremely dense breast tissue should use MRI for supplemental screening or US if MRI is not available. Women need to participate actively in the decision to undergo personalized screening. KEY RECOMMENDATIONS: Mammography is an effective imaging tool to diagnose breast cancer in an early stage and to reduce breast cancer mortality (evidence level I). Until more evidence is available to move to a personalized approach, regular mammography should be considered the mainstay of the breast cancer screening. High-risk women should start screening earlier; first with yearly breast MRI which can be supplemented by yearly or biennial mammography starting at 35-40 years old (evidence level I). Breast MRI screening should be also offered to women with extremely dense breasts (evidence level I). If MRI is not available, ultrasound can be performed as an alternative, although the added value of supplemental ultrasound regarding cancer detection remains limited. Individual screening recommendations should be made through a shared decision-making process between women and physicians.

6.
Eur Radiol ; 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39085641

RESUMEN

Breast complaints are frequent reasons for consultations in primary care or breast clinics. Breast pain, breast lumps, and nipple discharge are the most common complaints. Less common symptoms such as skin changes and axillary abnormalities also require specific diagnostic approaches. Imaging the symptomatic breast should be performed by appropriately trained breast radiologists following the best practice guidelines and quality standards. Full-field digital mammography (FFDM), digital breast tomosynthesis (DBT), and breast ultrasound (US) are the main modalities used in this primary setting. The choice depends on the patient's age and symptoms. Women younger than 30-years-old are first imaged by US, whereas women over 40-years-old usually require both FFDM or DBT and US. For women between 30-years-old and 40-years-old, the US is the modality of choice, whereas FFDM or DBT might also be performed if needed. Pregnant or lactating women with palpable lesions or nipple discharge are imaged with US as the first method; FFDM or DBT can also be performed depending on the degree of suspicion as the dose to the fetus is minimal, and shielding may even further reduce the dose. More advanced techniques such as breast magnetic resonance imaging or contrast-enhanced mammography are not indicated in this first diagnostic setting and are reserved for cases of established malignancy (local staging) or rare cases of equivocal findings not otherwise resolved or inflammatory breast cancer. Last, but not least, male breast symptoms should also be addressed with US and/or FFDM. CLINICAL RELEVANCE STATEMENT: It is equally important to correctly diagnose an underlying malignancy and to avoid false positives that would lead to unnecessary biopsies, increased costs, and anxiety for the patient. Proper use of imaging modalities ensures optimal diagnostic approach and minimizes false negatives. KEY POINTS: Ultrasound, full-field digital mammography, or digital breast tomosynthesis are the main imaging modalities in the diagnostic setting, while MRI or contrast-enhanced mammography should be reserved to selected cases. Initial imaging modality includes ultrasound combined with mammography or digital breast tomosynthesis depending on women's age and the presence (or not) of inconclusive findings. A negative imaging evaluation should not deter biopsy when a highly suspicious finding is found on physical examination.

7.
Eur Radiol ; 34(7): 4764-4773, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38112765

RESUMEN

OBJECTIVES: The aim of this study was to apply spatiotemporal analysis of contrast-enhanced ultrasound (CEUS) loops to quantify the enhancement heterogeneity for improving the differentiation between benign and malignant breast lesions. MATERIALS AND METHODS: This retrospective study included 120 women (age range, 18-82 years; mean, 52 years) scheduled for ultrasound-guided biopsy. With the aid of brightness-mode images, the border of each breast lesion was delineated in the CEUS images. Based on visual evaluation and quantitative metrics, the breast lesions were categorized into four grades of different levels of contrast enhancement. Grade-1 (hyper-enhanced) and grade-2 (partly-enhanced) breast lesions were included in the analysis. Four parameters reflecting enhancement heterogeneity were estimated by spatiotemporal analysis of neighboring time-intensity curves (TICs). By setting the threshold on mean parameter, the diagnostic performance of the four parameters for differentiating benign and malignant lesions was evaluated. RESULTS: Sixty-four of the 120 patients were categorized as grade 1 or 2 and used for estimating the four parameters. At the pixel level, mutual information and conditional entropy present significantly different values between the benign and malignant lesions (p < 0.001 in patients of grade 1, p = 0.002 in patients of grade 1 or 2). For the classification of breast lesions, mutual information produces the best diagnostic performance (AUC = 0.893 in patients of grade 1, AUC = 0.848 in patients of grade 1 or 2). CONCLUSIONS: The proposed spatiotemporal analysis for assessing the enhancement heterogeneity shows promising results to aid in the diagnosis of breast cancer by CEUS. CLINICAL RELEVANCE STATEMENT: The proposed spatiotemporal method can be developed as a standardized software to automatically quantify the enhancement heterogeneity of breast cancer on CEUS, possibly leading to the improved diagnostic accuracy of differentiation between benign and malignant lesions. KEY POINTS: • Advanced spatiotemporal analysis of ultrasound contrast-enhanced loops for aiding the differentiation of malignant or benign breast lesions. • Four parameters reflecting the enhancement heterogeneity were estimated in the hyper- and partly-enhanced breast lesions by analyzing the neighboring pixel-level time-intensity curves. • For the classification of hyper-enhanced breast lesions, mutual information produces the best diagnostic performance (AUC = 0.893).


Asunto(s)
Neoplasias de la Mama , Medios de Contraste , Ultrasonografía Mamaria , Humanos , Femenino , Persona de Mediana Edad , Adulto , Neoplasias de la Mama/diagnóstico por imagen , Anciano , Estudios Retrospectivos , Anciano de 80 o más Años , Ultrasonografía Mamaria/métodos , Diagnóstico Diferencial , Adolescente , Adulto Joven , Análisis Espacio-Temporal , Aumento de la Imagen/métodos
8.
Eur Radiol ; 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38967659

RESUMEN

OBJECTIVES: The aim of this study is to investigate the added value of diffusion-weighted imaging (DWI) to dynamic-contrast enhanced (DCE)-MRI to identify a pathological complete response (pCR) in patients with HER2-positive breast cancer and radiological complete response (rCR). MATERIALS AND METHODS: This is a single-center observational study of 102 patients with stage I-III HER2-positive breast cancer and real-world documented rCR on DCE-MRI. Patients were treated between 2015 and 2019. Both 1.5 T/3.0 T single-shot diffusion-weighted echo-planar sequence were used. Post neoadjuvant systemic treatment (NST) diffusion-weighted images were reviewed by two readers for visual evaluation and ADCmean. Discordant cases were resolved in a consensus meeting. pCR of the breast (ypT0/is) was used to calculate the negative predictive value (NPV). Breast pCR-percentages were tested with Fisher's exact test. ADCmean and ∆ADCmean(%) for patients with and without pCR were compared using a Mann-Whitney U-test. RESULTS: The NPV for DWI added to DCE is 86% compared to 87% for DCE alone in hormone receptor (HR)-/HER2-positive and 67% compared to 64% in HR-positive/HER2-positive breast cancer. Twenty-seven of 39 non-rCR DWI cases were false positives. In HR-positive/HER2-positive breast cancer the NPV for DCE MRI differs between MRI field strength (1.5 T: 50% vs. 3 T: 81% [p = 0.02]). ADCmean at baseline, post-NST, and ∆ADCmean were similar between patients with and without pCR. CONCLUSION: DWI has no clinically relevant effect on the NPV of DCE alone to identify a pCR in early HER2-positive breast cancer. The added value of DWI in HR-positive/HER2-positive breast cancer should be further investigated taken MRI field strength into account. CLINICAL RELEVANCE STATEMENT: The residual signal on DWI after neoadjuvant systemic therapy in cases with early HER2-positive breast cancer and no residual pathologic enhancement on DCE-MRI breast should not (yet) be considered in assessing a complete radiologic response. KEY POINTS: Radiologic complete response is associated with a pathologic complete response (pCR) in HER2+ breast cancer but further improvement is warranted. No relevant increase in negative predictive value was observed when DWI was added to DCE. Residual signal on DW-images without pathologic enhancement on DCE-MRI, does not indicate a lower chance of pCR.

9.
Eur Radiol ; 34(8): 5451-5460, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38240805

RESUMEN

OBJECTIVES: To assess the diagnostic performance of 3D automated breast ultrasound (3D-ABUS) in breast cancer screening in a clinical setting. MATERIALS AND METHODS: All patients who had 3D-ABUS between January 2014 and January 2022 for screening were included in this retrospective study. The images were reported by 1 of 6 breast radiologists based on the Breast Imaging Reporting and Data Systems (BI-RADS). The 3D-ABUS was reviewed together with the digital breast tomosynthesis (DBT). Recall rate, biopsy rate, positive predictive value (PPV) and cancer detection yield were calculated. RESULTS: In total, 3616 studies were performed in 1555 women (breast density C/D 95.5% (n = 3455/3616), breast density A/B 4.0% (n = 144/3616), density unknown (0.5% (n = 17/3616)). A total of 259 lesions were detected on 3D-ABUS (87.6% (n = 227/259) masses and 12.4% (n = 32/259) architectural distortions). The recall rate was 5.2% (n = 188/3616) (CI 4.5-6.0%) with only 36.7% (n = 69/188) cases recalled to another date. Moreover, recall declined over time. There were 3.4% (n = 123/3616) biopsies performed, with 52.8% (n = 65/123) biopsies due to an abnormality detected in 3D-ABUS alone. Ten of 65 lesions were malignant, resulting in a positive predictive value (PPV) of 15.4% (n = 10/65) (CI 7.6-26.5%)). The cancer detection yield of 3D-ABUS is 2.77 per 1000 screening tests (CI 1.30-5.1). CONCLUSION: The cancer detection yield of 3D-ABUS in a real clinical screening setting is comparable to the results reported in previous prospective studies, with lower recall and biopsy rates. 3D-ABUS also may be an alternative for screening when mammography is not possible or declined. CLINICAL RELEVANCE STATEMENT: 3D automated breast ultrasound screening performance in a clinical setting is comparable to previous prospective studies, with better recall and biopsy rates. KEY POINTS: • 3D automated breast ultrasound is a reliable and reproducible tool that provides a three-dimensional representation of the breast and allows image visualisation in axial, coronal and sagittal. • The diagnostic performance of 3D automated breast ultrasound in a real clinical setting is comparable to its performance in previously published prospective studies, with improved recall and biopsy rates. • 3D automated breast ultrasound is a useful adjunct to mammography in dense breasts and may be an alternative for screening when mammography is not possible or declined.


Asunto(s)
Neoplasias de la Mama , Imagenología Tridimensional , Ultrasonografía Mamaria , Humanos , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Estudios Retrospectivos , Ultrasonografía Mamaria/métodos , Persona de Mediana Edad , Imagenología Tridimensional/métodos , Adulto , Anciano , Detección Precoz del Cáncer/métodos , Mama/diagnóstico por imagen , Mama/patología , Reproducibilidad de los Resultados , Mamografía/métodos
10.
Eur Radiol ; 34(8): 5439-5450, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38227202

RESUMEN

OBJECTIVES: To perform a survey among members of the European Society of Breast Imaging (EUSOBI) regarding the use of contrast-enhanced mammography (CEM). METHODS: A panel of nine board-certified radiologists developed a 29-item online questionnaire, distributed to all EUSOBI members (inside and outside Europe) from January 25 to March 10, 2023. CEM implementation, examination protocols, reporting strategies, and current and future CEM indications were investigated. Replies were exploratively analyzed with descriptive and non-parametric statistics. RESULTS: Among 434 respondents (74.9% from Europe), 50% (217/434) declared to use CEM, 155/217 (71.4%) seeing less than 200 CEMs per year. CEM use was associated with academic settings and high breast imaging workload (p < 0.001). The lack of CEM adoption was most commonly due to the perceived absence of a clinical need (65.0%) and the lack of resources to acquire CEM-capable systems (37.3%). CEM protocols varied widely, but most respondents (61.3%) had already adopted the 2022 ACR CEM BI-RADS® lexicon. CEM use in patients with contraindications to MRI was the most common current indication (80.6%), followed by preoperative staging (68.7%). Patients with MRI contraindications also represented the most commonly foreseen CEM indication (88.0%), followed by the work-up of inconclusive findings at non-contrast examinations (61.5%) and supplemental imaging in dense breasts (53.0%). Respondents declaring CEM use and higher CEM experience gave significantly more current (p = 0.004) and future indications (p < 0.001). CONCLUSIONS: Despite a trend towards academic high-workload settings and its prevalent use in patients with MRI contraindications, CEM use and progressive experience were associated with increased confidence in the technique. CLINICAL RELEVANCE STATEMENT: In this first survey on contrast-enhanced mammography (CEM) use and perspectives among the European Society of Breast Imaging (EUSOBI) members, the perceived absence of a clinical need chiefly drove the 50% CEM adoption rate. CEM adoption and progressive experience were associated with more extended current and future indications. KEY POINTS: • Among the 434 members of the European Society of Breast Imaging who completed this survey, 50% declared to use contrast-enhanced mammography in clinical practice. • Due to the perceived absence of a clinical need, contrast-enhanced mammography (CEM) is still prevalently used as a replacement for MRI in patients with MRI contraindications. • The number of current and future CEM indications marked by respondents was associated with their degree of CEM experience.


Asunto(s)
Neoplasias de la Mama , Medios de Contraste , Mamografía , Sociedades Médicas , Humanos , Mamografía/métodos , Europa (Continente) , Femenino , Neoplasias de la Mama/diagnóstico por imagen , Encuestas y Cuestionarios , Pautas de la Práctica en Medicina/estadística & datos numéricos
11.
Eur Radiol ; 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38639912

RESUMEN

OBJECTIVES: Supplemental MRI screening improves early breast cancer detection and reduces interval cancers in women with extremely dense breasts in a cost-effective way. Recently, the European Society of Breast Imaging recommended offering MRI screening to women with extremely dense breasts, but the debate on whether to implement it in breast cancer screening programs is ongoing. Insight into the participant experience and willingness to re-attend is important for this discussion. METHODS: We calculated the re-attendance rates of the second and third MRI screening rounds of the DENSE trial. Moreover, we calculated age-adjusted odds ratios (ORs) to study the association between characteristics and re-attendance. Women who discontinued MRI screening were asked to provide one or more reasons for this. RESULTS: The re-attendance rates were 81.3% (3458/4252) and 85.2% (2693/3160) in the second and third MRI screening round, respectively. A high age (> 65 years), a very low BMI, lower education, not being employed, smoking, and no alcohol consumption were correlated with lower re-attendance rates. Moderate or high levels of pain, discomfort, or anxiety experienced during the previous MRI screening round were correlated with lower re-attendance rates. Finally, a plurality of women mentioned an examination-related inconvenience as a reason to discontinue screening (39.1% and 34.8% in the second and third screening round, respectively). CONCLUSIONS: The willingness of women with dense breasts to re-attend an ongoing MRI screening study is high. However, emphasis should be placed on improving the MRI experience to increase the re-attendance rate if widespread supplemental MRI screening is implemented. CLINICAL RELEVANCE STATEMENT: For many women, MRI is an acceptable screening method, as re-attendance rates were high - even for screening in a clinical trial setting. To further enhance the (re-)attendance rate, one possible approach could be improving the overall MRI experience. KEY POINTS: • The willingness to re-attend in an ongoing MRI screening study is high. • Pain, discomfort, and anxiety in the previous MRI screening round were related to lower re-attendance rates. • Emphasis should be placed on improving MRI experience to increase the re-attendance rate in supplemental MRI screening.

12.
Radiology ; 312(1): e241545, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39012253
16.
Radiol Clin North Am ; 62(4): 643-659, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38777540

RESUMEN

Breast MR imaging and contrast-enhanced mammography (CEM) are both techniques that employ intravenously injected contrast agent to assess breast lesions. This approach is associated with a very high sensitivity for malignant lesions that typically exhibit rapid enhancement due to the leakiness of neovasculature. CEM may be readily available at the breast imaging department and can be performed on the spot. Breast MR imaging provides stronger enhancement than the x-ray-based techniques and offers higher sensitivity. From a patient perspective, both modalities have their benefits and downsides; thus, patient preference could also play a role in the selection of the imaging technique.


Asunto(s)
Neoplasias de la Mama , Mama , Medios de Contraste , Imagen por Resonancia Magnética , Mamografía , Humanos , Imagen por Resonancia Magnética/métodos , Femenino , Mamografía/métodos , Neoplasias de la Mama/diagnóstico por imagen , Mama/diagnóstico por imagen , Aumento de la Imagen/métodos , Sensibilidad y Especificidad
17.
Ultrasound Med Biol ; 50(3): 358-363, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38103946

RESUMEN

OBJECTIVE: Studies have indicated that adding 2-D quasi-static elastography to B-mode ultrasound imaging improved the specificity for malignant lesion detection, as malignant lesions are often stiffer (increased strain ratio) compared with benign lesions. This method is limited by its user dependency and so unsuitable for breast screening. To overcome this limitation, we implemented quasi-static elastography in an automated breast volume scanner (ABVS), which is an operator-independent 3-D ultrasound system and is especially useful for screening women with dense breasts. The study aim was to investigate if 3-D quasi-static elastography implemented in a clinically used ABVS can discriminate between benign and malignant breast lesions. METHODS: Volumetric breast ultrasound radiofrequency data sets of 82 patients were acquired before and after automated transducer lifting. Lesions were annotated and strain was calculated using an in-house-developed strain algorithm. Two strain ratio types were calculated per lesion: using axial and maximal principal strain (i.e., strain in dominant direction). RESULTS: Forty-four lesions were detected: 9 carcinomas, 23 cysts and 12 other benign lesions. A significant difference was found between malignant (median: 1.7, range: [1.0-3.2]) and benign (1.0, [0.6-1.9]) using maximal principal strain ratios. Axial strain ratio did not reveal a significant difference between benign (0.6, [-12.7 to 4.9]) and malignant lesions (0.8, [-3.5 to 5.1]). CONCLUSION: Three-dimensional strain imaging was successfully implemented on a clinically used ABVS to obtain, visualize and analyze in vivo strain images in three dimensions. Results revealed that maximal principal strain ratios are significantly increased in malignant compared with benign lesions.


Asunto(s)
Neoplasias de la Mama , Diagnóstico por Imagen de Elasticidad , Femenino , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Sensibilidad y Especificidad , Mama/diagnóstico por imagen , Mama/patología , Ultrasonografía Mamaria/métodos , Algoritmos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Diagnóstico Diferencial
18.
Med Image Anal ; 97: 103269, 2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-39024973

RESUMEN

Lesion volume is an important predictor for prognosis in breast cancer. However, it is currently impossible to compute lesion volumes accurately from digital mammography data, which is the most popular and readily available imaging modality for breast cancer. We make a step towards a more accurate lesion volume measurement on digital mammograms by developing a model that allows to estimate lesion volumes on processed mammogram. Processed mammograms are the images routinely used by radiologists in clinical practice as well as in breast cancer screening and are available in medical centers. Processed mammograms are obtained from raw mammograms, which are the X-ray data coming directly from the scanner, by applying certain vendor-specific non-linear transformations. At the core of our volume estimation method is a physics-based algorithm for measuring lesion volumes on raw mammograms. We subsequently extend this algorithm to processed mammograms via a deep learning image-to-image translation model that produces synthetic raw mammograms from processed mammograms in a multi-vendor setting. We assess the reliability and validity of our method using a dataset of 1778 mammograms with an annotated mass. Firstly, we investigate the correlations between lesion volumes computed from mediolateral oblique and craniocaudal views, with a resulting Pearson correlation of 0.93 [95% confidence interval (CI) 0.92 - 0.93]. Secondly, we compare the resulting lesion volumes from true and synthetic raw data, with a resulting Pearson correlation of 0.998 [95%CI 0.998 - 0.998] . Finally, for a subset of 100 mammograms with a malignant mass and concurrent MRI examination available, we analyze the agreement between lesion volume on mammography and MRI, resulting in an intraclass correlation coefficient of 0.81 [95%CI 0.73 - 0.87] for consistency and 0.78 [95%CI 0.66 - 0.86] for absolute agreement. In conclusion, we developed an algorithm to measure mammographic lesion volume that reached excellent reliability and good validity, when using MRI as ground truth. The algorithm may play a role in lesion characterization and breast cancer prognostication on mammograms.

19.
J Womens Health (Larchmt) ; 33(4): 499-501, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38386779

RESUMEN

Background: Owing to its high sensitivity, as concluded in the Breast UltraSound Trial (BUST), targeted ultrasound (US) now seems a promising accurate stand-alone modality for diagnostic evaluation of breast complaints. This approach implies omission of bilateral digital breast tomosynthesis (DBT) in women with clearly benign US findings. Within BUST, radiologists started with US followed by DBT. This side-study investigates women's experiences with DBT, their main motivation to undergo diagnostic imaging, and their view on US as a stand-alone modality. Methods: A subset of BUST participants completed a questionnaire on their DBT experiences, reason for undergoing diagnostic assessment, and view on US-only diagnostics. Responses were analyzed with descriptive statistics and logistic regression analyses. Results: In total, 778 of 838 women (response rate 92.8%) were included (M = 47, SD = 11.16). Of them, 16.8% reported no burden of DBT, 33.5% slight burden, 31.0% moderate, and 12.7% severe burden. Furthermore, 13% reported no pain, 35.3% slight pain, 33.2% moderate, and 11.3% severe pain. Moreover, 88.3% indicated that the most important reason for breast assessment was explanation of their complaint and to rule out breast cancer, whereas 3.2% wanted to "check" both breasts. And 82.4% reported satisfaction with US only in case of a nonmalignancy. Conclusions: Our study shows that most women in the diagnostic setting experience at least slight-to-moderate DBT-related burden and pain, and that explanation for their symptoms is their main interest. Also, the majority report satisfaction with US only in case of nonmalignant findings. However, exploration of women's perspectives outside this study is needed as our participants all underwent both examinations.


Asunto(s)
Neoplasias de la Mama , Mamografía , Ultrasonografía Mamaria , Humanos , Femenino , Persona de Mediana Edad , Adulto , Ultrasonografía Mamaria/métodos , Encuestas y Cuestionarios , Neoplasias de la Mama/diagnóstico por imagen , Mama/diagnóstico por imagen , Satisfacción del Paciente/estadística & datos numéricos , Anciano
20.
Invest Radiol ; 59(7): 538-544, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38193779

RESUMEN

OBJECTIVES: This project aims to model an optimal scanning environment for breast magnetic resonance imaging (MRI) screening based on real-life data to identify to what extent the logistics of breast MRI can be optimized. MATERIALS AND METHODS: A novel concept for a breast MRI screening facility was developed considering layout of the building, workflow steps, used resources, and MRI protocols. The envisioned screening facility is person centered and aims for an efficient workflow-oriented design. Real-life data, collected from existing breast MRI screening workflows, during 62 scans in 3 different hospitals, were imported into a 3D simulation software for designing and testing new concepts. The model provided several realistic, virtual, logistical pathways for MRI screening and their outcome measures: throughput, waiting times, and other relevant variables. RESULTS: The total average appointment time in the baseline scenario was 25:54 minutes, with 19:06 minutes of MRI room occupation. Simulated improvements consisted of optimizing processes and resources, facility layout, and scanning protocol. In the simulation, time spent in the MRI room was reduced by introducing an optimized facility layout, dockable tables, and adoption of an abbreviated MRI scanning protocol. The total average appointment time was reduced to 19:36 minutes, and in this scenario, the MRI room was occupied for 06:21 minutes. In the most promising scenario, screening of about 68 people per day (10 hours) on a single MRI scanner could be feasible, compared with 36 people per day in the baseline scenario. CONCLUSIONS: This study suggests that by optimizing workflow MRI for breast screening total appointment duration and MRI occupation can be reduced. A throughput of up to 6 people per hour may be achieved, compared with 3 people per hour in the current setup.


Asunto(s)
Neoplasias de la Mama , Simulación por Computador , Imagen por Resonancia Magnética , Flujo de Trabajo , Humanos , Imagen por Resonancia Magnética/métodos , Femenino , Neoplasias de la Mama/diagnóstico por imagen , Atención Dirigida al Paciente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA