Anal Chem ; 84(6): 2614-21, 2012 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-22288440

RESUMEN

A new anion-selective polyvinyl chloride (PVC) membrane electrode based on {6,6'-diethoxy-2,2'-[2,2-dimethylpropane-1,3-diylbis(nitrilomethylidyne)]diphenolato}nickel(II)monohydrate as a carrier for the sulfate anion is reported. In this work, a new strategy for optimizing membrane components by electrochemical impedance spectroscopy (EIS) is presented. The performance of this electrode was investigated using potentiometric and EIS techniques. The potentiometric results indicated that the prepared electrode had a Nernstian slope of -28.9 ± 0.1 mV in a linear concentrations range of 1.0 × 10(-6) to 3.0 × 10(-1) M, a detection limit of 6.3 × 10(-7) M, an applied pH range of 4.0-9.0, and a response time of less than 15 s; while using the EIS technique, the linear concentrations range was 1.0 × 10(-9) to 1.0 × 10(-1) M and the pH range increased to 4.0-10.0. Finally, the impedance spectra were simulated using the Maple 13 software. A comparison of the experimental data and information obtained from the simulation confirmed the accuracy of the impedance measurement of this electrode.