Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Anal Chem ; 85(23): 11205-10, 2013 Dec 03.
Artículo en Inglés | MEDLINE | ID: mdl-24059493

RESUMEN

A new generation of hollow waveguide (HWG) gas cells of unprecedented compact dimensions facilitating low sample volumes suitable for broad- and narrow-band mid-infrared (MIR; 2.5-20 µm) sensing applications is reported: the substrate-integrated hollow waveguide (iHWG). iHWGs are layered structures providing light guiding channels integrated into a solid-state substrate material, which are competitive if not superior in performance to conventional leaky-mode fiber optic silica HWGs having similar optical pathlengths. In particular, the provided flexibility in device and optical design and the wide variety of manufacturing strategies, substrate materials, access to the optical channel, and optical coating options highlight the advantages of iHWGs in terms of robustness, compactness, and cost-effectiveness. Finally, the unmatched modularity of this novel waveguide approach facilitates tailoring iHWGs to almost any kind of gas sensor technology providing adaptability to the specific demands of a wide range of sensing scenarios. Device fabrication is demonstrated for the example of a yin-yang-shaped gold-coated iHWG fabricated within an aluminum substrate with a footprint of only 75 mm × 50 mm × 12 mm (L × W × H), yet providing a nominal optical absorption path length of more than 22 cm. The analytical utility of this device for advanced MIR gas sensing applications is demonstrated for the gaseous constituents butane, carbon dioxide, cyclopropane, isobutylene, and methane.

2.
Appl Spectrosc ; 76(1): 19-27, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34965744

RESUMEN

We have designed and demonstrated a quantum cascade laser (QCL) based standoff system that utilizes an uncooled mercury cadmium telluride (MCT) detector with lock-in signal processing for chemical identification at a distance of 12.5 meters in indoor ambient light conditions. In the system, a tunable quad-QCL operating (1 MHz) in quasi-continuous wave mode between 8.45 and 10.03 µm (∼1182 to 1000 cm-1) serves as the active mid-infrared source for remotely interrogating mineral, powder, and thin film oil samples including powder mixtures (6, 12.5, 25, and 50%) of crystalline quartz (SiO2) in KBr. Light as reflected from a given sample is collected using a 10-inch (25.4 cm) Dall Kirkham telescope and coupled with ZnSe optics to an uncooled MCT detector. The mixture dependence of the highly transparent KBr and strongly absorbing quartz was found to fit a modified version of the Schatz reflectance model for compacted powder mixtures. All reflectance spectra reported are relative to an Au-coated diffuse reflector. A NIST traceable polystyrene standard reflector was also used to determine the QCL wavelength tuning range and calibration.

3.
Opt Express ; 18(2): 1528-52, 2010 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-20173981

RESUMEN

The Large Synoptic Survey Telescope (LSST) uses a novel, three-mirror, modified Paul-Baker design, with an 8.4-meter primary mirror, a 3.4-m secondary, and a 5.0-m tertiary, along with three refractive corrector lenses to produce a flat focal plane with a field of view of 9.6 square degrees. In order to maintain image quality during operation, the deformations and rigid body motions of the three large mirrors must be actively controlled to minimize optical aberrations, which arise primarily from forces due to gravity and thermal expansion. We describe the methodology for measuring the telescope aberrations using a set of curvature wavefront sensors located in the four corners of the LSST camera focal plane. We present a comprehensive analysis of the wavefront sensing system, including the availability of reference stars, demonstrating that this system will perform to the specifications required to meet the LSST performance goals.


Asunto(s)
Astronomía/instrumentación , Diseño Asistido por Computadora , Aumento de la Imagen/instrumentación , Lentes , Refractometría/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo
4.
ACS Sens ; 2(9): 1287-1293, 2017 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-28792208

RESUMEN

In this study, an innovative approach based on fiberoptically coupled substrate-integrated hollow waveguide (iHWG) gas cells for the analysis of low sample volumes suitable for remote broad- and narrow-band mid-infrared (MIR; 2.5-20 µm) sensing applications is reported. The feasibility of remotely addressing iHWG gas cells, configured in a double-pass geometry via a reflector, by direct coupling to a 7-around-1 mid-infrared fiber bundle is demonstrated, facilitating low-level hydrocarbon gas analysis. For comparison studies, two iHWGs with substrate dimensions of 50 × 50 × 12 mm (L × W × H) and geometric channel lengths of 138 and 58.5 mm, serving as miniature light-guiding gas cells, were fiber-coupled to a Fourier transform infrared spectrometer enabling broadband MIR sensing. In addition to the fundamental feasibility of this concept, the achievable sensitivity toward several gaseous hydrocarbons and the reproducibility of assembling the fiber-iHWG interface were investigated.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA