Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Catheter Cardiovasc Interv ; 84(1): 7-16, 2014 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-24327421

RESUMEN

OBJECTIVES: The purpose of this study was to evaluate the 1-year clinical outcomes of more complex XIENCE V USA real-world patients with small versus nonsmall vessel lesions. BACKGROUND: Patients with small vessel lesions undergoing coronary stent placement are at higher risk of major adverse cardiac events. Improved safety and efficacy of XIENCE V everolimus eluting stents (EES) have been previously demonstrated in selected low-risk small vessel populations in randomized clinical trials. METHODS: The XIENCE V USA study was a condition of approval, single-arm study in unselected real-world patients. Baseline and 1-year clinical outcomes were compared between XIENCE V USA patients who received a single 2.5 mm stent (small vessel group, N = 838) and patients implanted with a single >2.5 mm stent (non-small vessel group, N = 2,015). Mean reference vessel diameter was 2.55 ± 0.36 and 3.25 ± 0.46 mm in the small and non-small vessel groups, respectively (P < 0.001). RESULTS: Small vessel group had more females, presented with a higher rate of diabetes, and had more complex lesion characteristics. The definite or probable ST rates analyzed using Kaplan-Meier method were low and not significantly different between the groups at 0.37 and 0.40% for the small and nonsmall vessel group (P = 0.88), respectively. The composite rate of cardiac death or MI was comparable at 4.5% for the small and 5.1% for the non-small vessel 1 groups (P = 0.57). The 1-year target lesion revascularization rate was also comparable in the small vessel group (3.8% vs. 3.0%, P = 0.35). CONCLUSIONS: Despite gender difference, higher prevalence of diabetes and more complex lesions in the small vessel groups, the 1-year clinical outcomes were similar in both small and nonsmall vessel groups. These results demonstrate the therapeutic benefit of XIENCE V EES in a real-world all inclusive patient population with small vessel disease.


Asunto(s)
Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/cirugía , Stents Liberadores de Fármacos , Revascularización Miocárdica/métodos , Vigilancia de Productos Comercializados/métodos , Sirolimus/análogos & derivados , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Everolimus , Femenino , Estudios de Seguimiento , Humanos , Inmunosupresores/farmacología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Sirolimus/farmacología , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 82(4): E385-94, 2013 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-23172848

RESUMEN

OBJECTIVES: The objective of this analysis was to evaluate the safety and effectiveness of XIENCE V in acute myocardial infarction (AMI). BACKGROUND: The XIENCE V(®) Everolimus-eluting coronary stent was superior to the TAXUS(®) paclitaxel-eluting stent in angiographic and clinical outcomes in the SPIRIT II, III, and IV randomized controlled trials, but patients with AMI were excluded. METHODS: XIENCE V USA is a large, prospective, multicenter, real-world single-arm postmarket surveillance trial. Consecutive patients undergoing PCI with XIENCE V were enrolled. For this analysis, clinical outcomes in 673 patients presenting with AMI (STEMI, n = 125) were as compared to patients without AMI (n = 3528) at 1 year. RESULTS: At 1 year, ARC-defined stent thrombosis (ST) rates were 1.08% in AMI vs. 0.85% in the non-AMI group (P = 0.4987). The late ST (30 days-1 year) rates were 0.31% vs. 0.47% (AMI vs. non-AMI, P = 0.7551). Rates of target lesion revascularization (TLR) were 4.1% vs. 4.6% (P = 0.6104), and rates of target lesion failure (TLF) were 9.1% vs. 8.5%, (P = 0.5964). With the historical WHO definition of MI, 1 year TLF rates were 7.0% vs. 6.7% (P = 0.8001). Improvements in quality of life, angina frequency, angina stability, and physical limitations occurred at 6 months (each P < 0.0001) and were sustained at 1 year in both groups. There were no significant differences in clinical outcomes between STEMI and non-STEMI patients. CONCLUSIONS: At 1 year, AMI patients treated with XIENCE V had low rates of ST, TLR, and TLF, similar to non-AMI patients. Marked improvements in patients' health status in this subgroup were also demonstrated.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Stents Liberadores de Fármacos , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea/instrumentación , Sirolimus/análogos & derivados , Anciano , Trombosis Coronaria/etiología , Everolimus , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/mortalidad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Vigilancia de Productos Comercializados , Estudios Prospectivos , Factores de Riesgo , Sirolimus/administración & dosificación , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
3.
J Interv Cardiol ; 25(6): 565-75, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22998355

RESUMEN

OBJECTIVES: This 2-year follow-up of the XIENCE V USA study examines both the long-term safety and effectiveness of the everolimus-eluting coronary stent system (EECSS) in real-world patients. BACKGROUND: The safety and effectiveness of EECSS at 1 year in real-world clinical settings have been demonstrated in XIENCE V USA trial with low rates of target lesion revascularization (TLR), cardiac death, myocardial infarction (MI), and stent thrombosis (ST). Data on whether efficacy is maintained after 1 year and the event rate of very late stent thrombosis (VLST) between 1 and 2 years have not yet been reported. METHODS: XIENCE V USA is a prospective, multicenter, single-arm, FDA required condition of approval study designed to examine the safety and effectiveness of EECSS in an all-inclusive, consecutively enrolled population from real-world clinical settings. Clinical end-point events, including ST, cardiac death, MI, and revascularization were adjudicated by an independent Clinical Events Committee. RESULTS: Four thousand eight hundred and seventy-three (96.4%) out of 5,054 participants (1,875 standard-risk; 3,059 extended-risk) reached 2-year follow-up. The 2-year rate of Academic Research Consortium (ARC)-defined definite and probable ST was 0.96% (95% CI 0.70-1.28) in the overall population and 0.34% (95% CI 0.12-0.74) and 1.33% (95% CI 0.95-1.81) in the standard-risk and extended-risk cohorts, respectively. The rate of VLST was 0.06% in the overall population, 0.0% in the standard-risk, and 0.10% in the extended-risk cohorts. The 2-year composite rate of cardiac death and ARC-defined MI was 8.9% (95% CI 8.08-9.70) in the overall population and 5.6% (95% CI 4.61-6.78) and 10.8% (95% CI 9.71-11.94) in the standard-risk and extended-risk cohorts, respectively. CONCLUSION: Low event rates observed at 1 year were maintained through 2 years. Despite the increased number of patients who discontinued dual antiplatelet therapy by 2 years, the ST rate remained consistently low, and <1% at 2 years due to low VLST occurrence. These results demonstrate continued safety and effectiveness of the XIENCE V everolimus-eluting stent in a highly complex, real-world patient population through 2 years.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Sirolimus/análogos & derivados , Angioplastia Coronaria con Balón , Everolimus , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/epidemiología , Estudios Prospectivos , Sirolimus/administración & dosificación , Trombosis/epidemiología , Estados Unidos/epidemiología
4.
JACC Cardiovasc Interv ; 5(6): 626-35, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22721657

RESUMEN

OBJECTIVES: The aim of this study was to identify predictors of clinical events after XIENCE V (Abbott Vascular, Santa Clara, California) stenting. BACKGROUND: The XIENCE V USA (XIENCE V Everolimus Eluting Coronary Stent System [EECSS] USA Post-Approval) study is a prospective, multicenter, Food and Drug Administration-required post-approval study to examine safety and effectiveness in real-world settings. After an initial 5,062 patients, 2,999 more were included as part of the DAPT (Dual Antiplatelet Therapy) trial (total n = 8,061). METHODS: One-year clinical events, including stent thrombosis (ST), cardiac death/myocardial infarction (MI), target lesion failure, and target lesion revascularization, were adjudicated according to Academic Research Consortium criteria, with ST and cardiac death/MI as primary and co-primary endpoints. Demographic, clinical, and procedural variables were assessed by multivariable analysis. A time-dependent covariate assessed the association between DAPT usage and ST. RESULTS: Roughly 61% were off-label; 85.6% remained on DAPT without interruption through 1 year. Incidences of definite/probable ST, cardiac death/MI, target lesion failure, and target lesion revascularization were 0.80% (95% confidence interval [CI]: 0.61% to 1.03%), 7.1% (95% CI: 6.51% to 7.68%), 8.9% (95% CI: 8.30% to 9.60%), and 4.3% (95% CI: 3.82% to 4.75%), respectively. Several independent clinical and angiographic predictors were identified for each outcome. Predictors of ST included DAPT interruption ≤ 30 days (hazard ratio [HR]: 8.63, 95% CI: 2.69 to 27.73, p = 0.0003), renal insufficiency (HR: 3.72, 95% CI: 1.71 to 8.09, p = 0.0009), and total stent length (HR: 1.30, 95% CI: 1.16 to 1.47, p < 0.0001). A DAPT interruption >30 days was not predictive of ST. CONCLUSIONS: In this large, real-world population, XIENCE V demonstrated low event rates at 1 year, with several independent predictors. Early DAPT interruption (≤ 30 days) was the most potent predictor of ST, whereas delayed interruption (>30 days) was not predictive. (XIENCE V Everolimus Eluting Coronary Stent System [EECSS] USA Post-Approval Study; NCT00676520).


Asunto(s)
Angioplastia Coronaria con Balón/efectos adversos , Enfermedad de la Arteria Coronaria/terapia , Trombosis Coronaria/etiología , Anciano , Angioplastia Coronaria con Balón/instrumentación , Angioplastia Coronaria con Balón/mortalidad , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/mortalidad , Quimioterapia Combinada , Stents Liberadores de Fármacos , Everolimus , Femenino , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Análisis Multivariante , Infarto del Miocardio/etiología , Infarto del Miocardio/mortalidad , Inhibidores de Agregación Plaquetaria/administración & dosificación , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Diseño de Prótesis , Medición de Riesgo , Factores de Riesgo , Sirolimus/administración & dosificación , Sirolimus/análogos & derivados , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos/epidemiología
5.
JACC Cardiovasc Interv ; 4(12): 1298-309, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22192371

RESUMEN

OBJECTIVES: The XIENCE V USA (XIENCE V Everolimus Eluting Coronary Stent System Condition-of-Approval Post-Market study) sought to: 1) evaluate the safety of everolimus-eluting coronary stent systems (EECSS) in a contemporary cohort of real-world subjects; and 2) prospectively test the quality of event reporting with analysis of matched patients from the randomized SPIRIT IV (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Subjects With de Novo Native Coronary Artery Lesions) trial. BACKGROUND: Randomized trials have demonstrated the safety and efficacy of EECSS in selected "standard-risk" patients. METHODS: The XIENCE V USA trial was a prospective, multicenter, single-arm study in unselected patients. The primary endpoint was Academic Research Consortium (ARC)-defined definite and probable stent thrombosis (ST); the co-primary endpoint was the composite of cardiac death and myocardial infarction at 1 year. Secondary analyses included: 1) stratification by standard-risk and extended-risk cohorts; and 2) late ST after dual antiplatelet therapy interruption. RESULTS: Of 5,054 participants (1,875 standard-risk; 3,179 extended-risk), 4,958 (98.1%) reached 1-year follow-up. The rate of ARC-defined definite and probable ST was 0.84% (95% confidence interval [CI]: 0.60% to 1.14%) in the overall population and 0.33% (95% CI: 0.12% to 10.72%) and 1.14% (95% CI: 0.80% to 11.58%) in the standard-risk and extended-risk cohorts, respectively. No late ST was observed after dual antiplatelet therapy interruption in either cohort after 6 months. The composite rate of cardiac death and ARC-defined myocardial infarction was 6.5% (95% CI: 5.79% to 17.17%) in the overall population, 3.8% (95% CI: 2.98% to 14.78%) in the standard-risk cohort, and 8.0% (95% CI: 7.09% to 19.02%) in the extended-risk cohort. CONCLUSIONS: This study comprehensively reports ST rates for EECSS in a contemporary real-world population. The absence of ST after dual antiplatelet therapy interruption beyond 6 months in standard-risk and high-risk patients is notable. Consistent safety outcomes between matched standard-risk cohorts from the XIENCE V USA study and the SPIRIT IV randomized trial suggest that this study affords a reliable benchmark for understanding the safety of EECSS in the context of real-world clinical practice. (XIENCE V Everolimus Eluting Coronary Stent System [EECSS] USA Post-Approval Study; NCT00676520).


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Sirolimus/análogos & derivados , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Benchmarking , Enfermedad de la Arteria Coronaria/mortalidad , Aprobación de Recursos/normas , Everolimus , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Inhibidores de Agregación Plaquetaria/administración & dosificación , Vigilancia de Productos Comercializados/normas , Estudios Prospectivos , Diseño de Prótesis , Medición de Riesgo , Factores de Riesgo , Sirolimus/administración & dosificación , Trombosis/etiología , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA