Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Int Endod J ; 57(5): 601-616, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38376108

RESUMEN

AIM: To compare eight large- and low-tapered heat-treated reciprocating instruments regarding their design, metallurgy, mechanical properties, and irrigation flow through an in silico model. METHODOLOGY: A total of 472 new 25-mm E-Flex Rex (25/.04 and 25/.06), Excalibur (25/.05), Procodile (25/.06), Reciproc Blue R25 (25/.08v), WaveOne Gold Primary (25/.07v), and Univy Sense (25/.04 and 25/.06) instruments were evaluated regarding their design (stereomicroscopy, scanning electron microscopy, and 3D surface scanning), metallurgy (energy-dispersive X-ray spectroscopy and differential scanning calorimetry), and mechanical performance (cyclic fatigue, torsional resistance, cutting ability, bending and buckling resistance). Computational fluid dynamics assessment was also conducted to determine the irrigation flow pattern, apical pressure, and wall shear stress in simulated canal preparations. Kruskal-Wallis and one-way anova post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS: Instruments presented variations in blade numbers, helical angles, and tip designs, with all featuring non-active tips, symmetrical blades, and equiatomic nickel-titanium ratios. Cross-sectional designs exhibited an S-shaped geometry, except for WaveOne Gold. Univy 25/.04 and Reciproc Blue displayed the smallest and largest core diameters at D3. Univy 25/.04 and E-Flex Rec 25/.04 demonstrated the longest time to fracture (p < .05). Reciproc Blue and Univy 25/.04 exhibited the highest and lowest torque to fracture, respectively (p < .05). Univy 25/.04 and Reciproc Blue had the highest rotation angles, whilst E-Flex Rec 25/.06 showed the lowest angle (p < .05). The better cutting ability was observed with E-Flex Rec 25/.06, Procodile, Excalibur, and Reciproc Blue (p > .05). Reciproc R25 and E-Flex Rec showed the highest buckling resistance values (p < .05), with WaveOne Gold being the least flexible instrument. The impact of instruments' size and taper on wall shear stress and apical pressure did not follow a distinct pattern, although Univy 25/.04 and E-Flex Rec 25/.06 yielded the highest and lowest values for both parameters, respectively. CONCLUSIONS: Low-tapered reciprocating instruments exhibit increased flexibility, higher time to fracture, and greater angles of rotation, coupled with reduced maximum bending loads and buckling strength compared to large-tapered instruments. Nevertheless, low-tapered systems also exhibit lower maximum torque to fracture and inferior cutting ability, contributing to a narrower apical canal enlargement that may compromise the penetration of irrigants in that region.


Asunto(s)
Instrumentos Dentales , Titanio , Estudios Transversales , Diseño de Equipo , Ensayo de Materiales , Estrés Mecánico , Titanio/química , Preparación del Conducto Radicular , Metalurgia
2.
Clin Oral Investig ; 28(3): 201, 2024 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-38453706

RESUMEN

OBJECTIVES: The aim of this study was to assess cone beam computed tomography (CBCT) as a root canal anatomy diagnostic tool by comparison with micro-CT gold-standard. MATERIALS AND METHODS: 216 two-rooted mandibular molars were first scanned in a CBCT device (200 µm voxel size) and posteriorly in a micro-CT scanner (19.61 µm). The volumes were sequentially screened to classify main root canal anatomy according to Vertucci classification, and for the presence of lateral canals and apical deltas, in both mesial and distal roots. RESULTS: Both methods revealed a higher prevalence of Vertucci Type II and IV in the mesial root, and Vertucci Type I in the distal root. The percentage of agreement for main root canal anatomy classification between CBCT and micro-CT scores was high (85.2%). CONCLUSION: Sensibility to detect both lateral canals and apical deltas with CBCT was low. These results attest to the fact that minor anatomical changes might be difficult to identify with CBCT imaging, hampering its diagnostic value.


Asunto(s)
Cavidad Pulpar , Mandíbula , Cavidad Pulpar/diagnóstico por imagen , Cavidad Pulpar/anatomía & histología , Microtomografía por Rayos X , Mandíbula/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico/métodos , Raíz del Diente/diagnóstico por imagen , Raíz del Diente/anatomía & histología
3.
Int Endod J ; 56(7): 896-908, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37029571

RESUMEN

AIM: To compare two flat-side single-file rotary instruments with three single-file reciprocating systems through a multimethod assessment. METHODOLOGY: A total of 290 new NiTi single-file rotary (AF F One Blue 25/0.06 and Platinum V.EU 25/0.06) and reciprocating (One Files Blue R25, Reciproc Blue R25, Reciproc R25) instruments were selected, carefully examined for any major deformations, and evaluated regarding their macroscopic and microscopic design, nickel and titanium elements ratio, phase transformation temperatures, and mechanical performance (time/rotation to fracture, maximum torque, angle of rotation, microhardness, maximum bending, and buckling strengths). One-way anova post hoc Tukey, T-test, and nonparametric Mood's median tests were used for statistical comparisons (α = 5%). RESULTS: Tested instruments had identical blade counts and near-identical helical angles of approximately 24° (rotary instruments) and 151° (reciprocating instruments). The flat-side analysis revealed a few inconsistencies, such as discontinuity segments, different orientations, and gaps in the homogeneity of the bluish colour. Microscopically, flat-side instruments exhibited blade discontinuity and an incomplete S-shaped cross-section. The surface finish was smoother for One Files Blue and more irregular for both rotary instruments. There were distinct phase transformation temperatures amongst all instruments. All heat-treated instruments were in R-phase arrangement, and Reciproc was in R-phase plus austenite at test temperature (20°C). Compared with the reciprocating instruments, both flat-side instruments exhibited lower results in the cyclic fatigue tests using two different clockwise kinematics, maximum torque, angle of rotation, and maximum buckling strength (p < .05). The rotary systems also exhibited low flexibility (p < .05). AF F One Blue had the lowest microhardness, whilst Reciproc had the highest value. CONCLUSION: This multimethod investigation revealed that the flat-side rotary instruments underperformed the reciprocating instruments regarding cyclic fatigue (with two different clockwise kinematics), maximum torque, angle of rotation, maximum buckling strength, and flexibility. Manufacturing inconsistencies were also observed in some of the flat-side instruments, including discontinuity segments, different orientations, and in the homogeneity of their bluish colour given by the heat treatment.


Asunto(s)
Instrumentos Dentales , Calor , Diseño de Equipo , Preparación del Conducto Radicular , Ensayo de Materiales , Titanio , Estrés Mecánico
4.
Int Endod J ; 56(10): 1301-1315, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37594701

RESUMEN

AIM: To assess the influence of a flat-side design on the geometry, metallurgy, mechanical performance and shaping ability of a novel nickel-titanium rotary instrument. METHODOLOGY: Sixty-five new 25-mm flat-side rotary instruments (size 25, taper 0.04) and their nonflat-side prototypes (n = 65) were assessed for major deformations and examined regarding macroscopic and microscopic design, determination of nickel and titanium elements ratio, measurement of phase transformation temperature and evaluation of mechanical performance parameters including time/cycles to fracture, maximum torque, angle of rotation, maximum bending and buckling strengths and cutting ability. Additionally, unprepared canal areas, volume of hard tissue debris and percentage reduction of dentine thickness were calculated for each tested instrument after preparing mesial canals of mandibular molars (n = 12), using micro-CT imaging. Statistical analyses were performed using the U-Mann-Whitney test and independent Student t-test (α = 5%). RESULTS: The number of spirals (n = 8) and blade direction (clockwise) were similar between both flat and nonflat instruments, whilst the helical angles were equivalent (⁓25°). Flat-instruments showed inconsistencies in the homogeneity of the gold colour on the flat-side surface, blade discontinuity, and incomplete and variable S-shaped cross-sections. The titanium-to-nickel ratios were equivalent, but significant differences in the R-phase finish and austenitic start phase transformation temperatures were observed between the flat and nonflat-side instruments. The flat-side instruments demonstrated superior cutting ability compared to the nonflat instruments, as well as, significantly lower values for time to fracture, rotation to fracture and maximum torque to fracture (p < .001). No statistical difference was observed between tested instruments regarding angle of rotation (p = .437), maximum bending (p = .152) and buckling load (p = .411). Preparation protocols using flat and nonflat instruments did not show any statistically significant differences (p > .05). All flat-side instruments exhibited deformation after shaping procedures. CONCLUSIONS: The flat-side instrument showcased enhanced cutting ability compared to its nonflat counterpart. However, it exhibited inferior performance in terms of time, rotation and maximum torque to fracture, along with distinct phase transformation temperatures. No differences were observed in the titanium-to-nickel ratios, angle of rotation, maximum bending, buckling load, preparation time, percentage of untouched canal walls, volume of hard tissue debris and percentage reduction of dentine thickness.


Asunto(s)
Níquel , Titanio , Humanos , Cavidad Pulpar , Metalurgia , Diente Molar
5.
Int Endod J ; 56(4): 530-542, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36508297

RESUMEN

AIM: To compare design, metallurgy and mechanical performance of the ProTaper (PT) Ultimate system with instruments of similar dimensions from the ProGlider, PT Gold and PT Universal systems. METHODOLOGY: New PT Ultimate instruments (n = 248) were compared with instruments of similar dimensions from ProGlider (n = 31), PT Gold (n = 155) and PT Universal (n = 155) systems regarding their number of spirals, helical angle, blade symmetry, tip geometry, surface finishing, nickel/titanium ratio, phase transformation temperatures and mechanical performance. One-way anova and nonparametric Mood's median tests were used for statistical comparison (α = 5%). RESULTS: All instruments had symmetrical blades without radial lands or flat sides, similar surface finishing and an almost equiatomic nickel/titanium ratio, whilst the number of spirals, helical angles and the tip geometry were different. PT Ultimate instruments showed 3 distinct heat treatments that matched with the colour of their metal wire. Slider and ProGlider instruments had similar R-phase start (Rs) and R-phase finish (Rf) temperatures. SX, F1, F2, F3 and Shaper instruments showed equivalent heat treatments (Rs ~45.6°C and Rf ~28.3°C) that were similar to their PT Gold counterparts (Rs ~47.9°C and Rf ~28.2°C), but completely distinct to the PT Universal ones (Rs ~16.2°C and Rf ~-18.2°C). Amongst the PT Ultimate instruments, the lowest maximum torques were observed in the SX (0.44 N cm), Slider (0.45 N cm) and Shaper (0.60 N cm) instruments, whilst the highest was noted in the FXL (4.90 N cm). PT Ultimate Slider and ProGlider had similar torsional (~0.40 N cm) and bending loads (~145.0 gf) (p = 1.000), whilst the other PT Ultimate instruments showed statistically significantly lower maximum torque, higher angle of rotation and lower bending load (higher flexibility) than their counterparts of the PT Universal and PT Gold systems. CONCLUSIONS: The PT Ultimate system comprises instruments with 3 distinct heat treatments that showed similar phase transformation temperatures to their heat-treated analogues. PT Ultimate instruments presented lower torsional strength and superior flexibility than their counterparts, whilst maximum torque, angle of rotation and bending loads progressively increased with their sizes.


Asunto(s)
Níquel , Titanio , Calor , Falla de Equipo , Ensayo de Materiales , Aleaciones Dentales , Preparación del Conducto Radicular , Diseño de Equipo , Torsión Mecánica
6.
Int Endod J ; 56(11): 1412-1428, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37698946

RESUMEN

AIM: To compare the design, metallurgy, and mechanical properties of four heat-treated reciprocating instruments coupled with the evaluation of the irrigation flow using an in silico model. METHODOLOGY: New EdgeOne Fire Primary, Easy-File Flex Regular 25, WaveOne Gold Primary and Reciproc Blue R25 instruments (n = 124) were initially evaluated regarding their design through stereomicroscopy, scanning electron microscopy and 3D surface scanning. In addition, energy-dispersive X-ray spectroscopy was utilized to determine their elemental composition, and differential scanning calorimetry tests to evaluate their phase transformation temperatures. Their mechanical performance was further assessed through torsional and bending tests. Using scans obtained from a real tooth and the instruments, a computational fluid dynamics assessment was conducted to determine the irrigation flow pattern, apical pressure, and wall shear stress in simulated canal preparation. Mood's median and One-way anova post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS: Reciproc Blue exhibited a superior number of blades (n = 8), whereas EdgeOne Fire had the highest overall volume (4.38 mm3 ) and surface area (32.32 mm2 ). At the 3-mm axial level, EdgeOne Fire displayed the lowest core diameter (0.13 mm), while Reciproc Blue had the highest (0.16 mm). All blades were symmetrical, and the tips of the instruments were non-active but differed from each other. The most irregular surfaces were observed in EdgeOne Fire and Easy-File Flex. All instruments were manufactured from nickel-titanium alloys and exhibited distinct phase transformation temperatures. WaveOne Gold and Reciproc Blue demonstrated the highest maximum torque values (1.87 and 1.62 N cm, respectively), while the lowest was observed on EdgeOne Fire (1.21 N cm) (p < .05). The most flexible (p < .05) were EdgeOne Fire (angle of rotation: 602.6°; maximum bending load: 251.4 g.f) and Reciproc Blue (533.2° and 235.6 g.f). There were no significant differences observed in the irrigation flow among the four domains generated by the tested instruments. CONCLUSIONS: Despite observing variations in the design, phase transformation temperatures, and in the torsional and bending test outcomes among the four heat-treated reciprocating instruments, no significant differences were found in the irrigation flow pattern among the different groups in the simulated root canal preparations.


Asunto(s)
Instrumentos Dentales , Calor , Diseño de Equipo , Estrés Mecánico , Preparación del Conducto Radicular , Titanio/química , Metalurgia , Oro , Ensayo de Materiales
7.
Int Endod J ; 56(6): 775-785, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36942476

RESUMEN

AIM: This study aimed to compare three rotary instruments produced by the EDM process with the heat-treated ProTaper Gold system regarding design, metallurgy, mechanical properties and shaping ability. METHODOLOGY: HyFlex EDM (25/~), Neoniti (25/.06), EDMax (25/.06) and ProTaper Gold (25/.08v) instruments (n = 58 per group) were compared regarding design, metallurgy and mechanical performance. Unprepared canal areas were calculated for each system after preparation of mesiobuccal, mesiolingual and distal canals of mandibular molars (15 canals per group) using micro-CT technology. Statistical analyses were performed using One-way anova post-hoc Tukey and Kruskal-Wallis post-hoc Dunn's tests (α = 5%). RESULTS: All instruments had asymmetrical blades, no radial lands, no major defects and almost equiatomic nickel/titanium ratios, but different cross-section designs, tip geometries and surface appearances. Although instruments had distinct transformation temperature curves, they showed crystallographic martensitic arrangement at 21°C and mixed austenite plus R-phase at body temperature. Neoniti and HyFlex EDM showed similar results in all mechanical tests (p > .05), while EDMax and ProTaper Gold had similar time to fracture (p = .841), maximum bending load (p = .729), and cutting ability (p = .985). ProTaper Gold showed the highest torque to failure (p < .001) and HyFlex EDM had the lowest buckling resistance (p < .001). Mean percentages of unprepared canal areas ranged from 20.4% to 25.7% in the mesial canals, and from 20.8% to 26.2% in the distal canal, with no statistical differences among systems (p > .05). CONCLUSIONS: Instruments' geometry and phase transformation temperatures influenced the results of the mechanical tests, but not their shaping ability.


Asunto(s)
Preparación del Conducto Radicular , Humanos , Aleaciones Dentales/química , Instrumentos Dentales , Diseño de Equipo , Ensayo de Materiales , Temperatura , Titanio/química , Torque
8.
Clin Oral Investig ; 27(8): 4667-4675, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37247087

RESUMEN

OBJECTIVE: This study aimed to evaluate changes on root canal morphology in patients with different ages using micro-CT technology. MATERIALS AND METHODS: Mandibular first molars (n = 150) were scanned at a pixel size of 13.68 µm, categorized into 3 groups according to patient's age and analyzed regarding configuration, orifices, apical foramina, root length, canal volume, and surface area. Morphological 2D and 3D parameters were evaluated in distal roots with Type I configuration (n = 109) as well as the morphology of isthmuses Types I and III in 68 mesial roots. One-way ANOVA post hoc Tukey and Kruskal-Wallis tests were used for statistical analyses (α = 5%). RESULTS: A great variation in the canal configuration was found. No difference was observed in roots' length (p > 0.05). Canal volume reduced with age (p < 0.05), while surface area increased (p < 0.05) in patients ≤ 30 years. There was no difference in canal/root length, area, and from foramen to the apex in distal roots with Type I configuration (p > 0.05), but 2D and 3D parameters significantly decreased with age (p < 0.05). Overall, the diameter of the isthmuses' roof reduced with age (p < 0.05). In patients ≥ 31 years with Type III isthmus the distance from the isthmus floor to the foramen of the mesiolingual canal also decreased (p < 0.05). CONCLUSION: Overall, the internal morphology of the mesial roots of mandibular first molars was more affected by aging than distal canals. The most relevant tested parameter that significantly reduced in both roots was the volume of the root canal systems. CLINICAL RELEVANCE: A detailed evaluation of fine anatomical aspects of the root canal system of mandibular first molars of patients with different ages showed that the internal morphology of mesial roots is more affected by aging than distal canals.


Asunto(s)
Cavidad Pulpar , Mandíbula , Humanos , Cavidad Pulpar/diagnóstico por imagen , Cavidad Pulpar/anatomía & histología , Microtomografía por Rayos X , Mandíbula/diagnóstico por imagen , Mandíbula/anatomía & histología , Tratamiento del Conducto Radicular , Diente Molar/diagnóstico por imagen , Diente Molar/anatomía & histología , Raíz del Diente/diagnóstico por imagen , Raíz del Diente/anatomía & histología
9.
Clin Oral Investig ; 27(5): 2427-2436, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36749411

RESUMEN

OBJECTIVE: This study aimed to compare 3 reciprocating systems regarding design, metallurgy, mechanical properties, and shaping ability. MATERIALS AND METHODS: New Reciproc Blue R25, WaveOne Gold Primary, and REX 25 instruments (n=41 per group) were analyzed regarding design, metallurgy, and mechanical performance, while shaping ability (untouched canal walls, volume of removed dentin, and hard tissue debris) was tested in 36 anatomically matched root canals of mandibular molars. Results were compared using one-way ANOVA post hoc Tukey and Kruskal-Wallis tests with a significant level set at 5%. RESULTS: All instruments showed symmetrical cross sections with asymmetrical blades, no radial lands, no major defects, and an almost equiatomic nickel and titanium ratio. The highest R-phase start temperatures were observed with WaveOne Gold (46.1°C) and REX (44.8°C), while Reciproc Blue had the lowest R-phase start (34.5°C) and finish (20°C) temperatures. WaveOne Gold had the lowest time to fracture (169 s) and the highest maximum load (301.6 gf) (P <0.05). The maximum torque of Reciproc Blue (2.2 N.cm) and WaveOne Gold (2.1 N.cm) were similar (P >0.05), but lower than REX (2.6 N.cm) (P <0.05). No statistical differences were observed among instruments in the angle of rotation (P >0.05) and in the shaping ability in both mesial and distal canals (P >0.05). CONCLUSION: Although the overall design, temperature transition phases and mechanical behavior parameters were different among tested instruments, they were similar in terms of shaping ability. CLINICAL RELEVANCE: All tested heat-treated NiTi reciprocating systems showed similar shaping ability, without clinically significant errors.


Asunto(s)
Calor , Preparación del Conducto Radicular , Instrumentos Dentales , Diseño de Equipo , Titanio , Metalurgia , Ensayo de Materiales
10.
Int Endod J ; 55(1): 30-37, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34676902

RESUMEN

AIM: To describe the prevalence of periapical lesions, root canal treatments and coronal restorations on teeth adjacent to either implant- or natural tooth-supported crowns using cone-beam computed tomography (CBCT) assessment compared to nonadjacent teeth. METHODOLOGY: A total of 1249 CBCT volumes were screened by five pre-calibrated observers in 11 health centres. A step-by-step screening protocol was implemented and reviewed every 3 months, and mandatory setting characteristics were established for all CBCT scans using dedicated visualization software. Intra- and inter-rater reliability tests were conducted. The prevalence of periapical lesions, root canal treatments and coronal restorations was recorded on both teeth adjacent and nonadjacent to implant- (predictor 1) or natural tooth-supported crowns (predictor 2). A binary logistic model (Generalizing Estimating Equations test) was used to verify whether the prevalence of periapical lesion, root canal filling and the tooth restorative status are altered when the assessed tooth is adjacent or not to an implant-supported crown (predictor 1); or to a natural tooth-supported crown (predictor 2). Odds ratio and confidence intervals for the dependent variables at both predictors were obtained. The significance level was set at .05. RESULTS: A global sample of 22 899 teeth was included. Compared to nonadjacent teeth, the prevalence of periapical lesion, root canals treatments and restorative procedures when adjacent to implant-supported crowns was 10.7%, 19.6% and 22.9% higher, respectively, and when adjacent to tooth-supported crowns was 19.3%, 35.6% and 37.4% higher respectively. These results were significant only for variables root canal filling and coronal restoration (p < .0001). Odds ratio to present root canal treatment is 2.57 times higher (CI 1.95-3.39, p = .0001) when the tooth is adjacent to implant-supported crown and 4.39 times (CI 3.49-5.53, p = .0001) when adjacent to tooth-supported crown, whilst for restorative procedure, the odds are, respectively, 1.63 (CI 1.29-2.06, p = .0001) and 2.30 (CI 1.92-2.76, p = .0001). CONCLUSIONS: Teeth adjacent to both implant- and natural tooth-supported crowns were associated with a higher frequency of root canal filling and coronal restorations.


Asunto(s)
Cavidad Pulpar , Periodontitis Periapical , Estudios Transversales , Coronas , Humanos , Prevalencia , Reproducibilidad de los Resultados
11.
Int Endod J ; 55(12): 1394-1403, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36040378

RESUMEN

AIM: This study aimed to experimentally validate a computational fluid dynamics (CFD) model, using micro-particle image velocimetry (micro-PIV) measurements of the irrigation flow velocity field developed in confluent canals during irrigation with a side-vented needle. METHODOLOGY: A microchip with confluent canals, manufactured in polydimethylsiloxane was used in a micro-PIV analysis of the irrigation flow using a side-vented needle placed 3 mm from the end of the confluence of the canals. Velocity fields and profiles were recorded for flow rates of 0.017 and 0.1 ml/s and compared with those predicted in CFD numerical simulations (using a finite volume commercial code - FLUENT) for both laminar and turbulent regimes. RESULTS: The overall flow pattern, isovelocity and vector maps as well as velocity profiles showed a close agreement between the micro-PIV experimental and CFD predicted data. No relevant differences were observed between the results obtained with the laminar and turbulent flow models used. CONCLUSIONS: Results showed that the laminar CFD modelling is reliable to predict the flow in similar domains.


Asunto(s)
Hidrodinámica , Agujas , Simulación por Computador , Reología , Endodoncia
12.
Int Endod J ; 55(11): 1262-1273, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35993556

RESUMEN

AIM: To evaluate the effects of progressive root canal enlargements on the unprepared surface area and remaining dentine thickness of three-rooted maxillary first premolars with different root configurations. METHODOLOGY: Thirty three-rooted maxillary first premolars with three root configurations (n = 10) were selected and scanned in a micro-CT device. The root canals were sequentially enlarged with rotary instruments sizes 30.02 (step 1), 30.04 (step 2) and 30.06 (step 3). After each step, a new scan was taken. Analysed parameters included morphometric measurements (length, volume and surface area), number of static voxels and minimal dentine thickness. Statistical analyses were performed with one-way anova post hoc Tukey tests and paired sample t-test at a significance level of 5%. RESULTS: No statistical differences were observed amongst groups regarding the morphometric parameters and static voxels (p > .05). The minimal dentine thickness of the distobuccal root significantly changed depending on the root configuration (p < .05), whilst no differences were observed in the other roots (p > .05). A great variation in the position of the minimal dentine thickness was observed after preparation. Overall, mean percentage reduction in dentine thickness was higher in the buccal roots than in the palatal root (p < .05). In the mesiobuccal and distobuccal root, the number of slices with minimal dentine thickness lower than 0.05 mm increases 2 to 3 times and 3 to 4 times, respectively, from steps 1 to 3. CONCLUSIONS: Instruments sizes 30.02 and 30.04 can be safely and effectively used to enlarge the buccal and palatal canals of three-rooted maxillary first premolars.


Asunto(s)
Cavidad Pulpar , Maxilar , Diente Premolar/diagnóstico por imagen , Cavidad Pulpar/diagnóstico por imagen , Dentina/diagnóstico por imagen , Maxilar/diagnóstico por imagen , Preparación del Conducto Radicular , Raíz del Diente/diagnóstico por imagen , Microtomografía por Rayos X
13.
Clin Oral Investig ; 26(3): 3299-3310, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34860307

RESUMEN

OBJECTIVES: To compare the design, metallurgy, mechanical performance, and canal preparation of 5 rotary systems. MATERIAL AND METHODS: A total of 735 25-mm NiTi instruments (sizes 0.17[0.18]/.02v, 0.20/.04v, 0.20/.07v, 0.25/.08v, 0.30/.09v) from ProTaper Gold, ProTaper Universal, Premium Taper Gold, Go-Taper Flex, and U-File systems were compared regarding overall geometry and surface finishing (stereomicroscopy and scanning electron microscopy), nickel and titanium ratio (energy-dispersive spectroscopy), phase transformation temperatures (differential scanning calorimetry), mechanical performance (torsional and bending tests), and unprepared canal surface (micro-CT). One-way ANOVA and Mood's median tests were used for statistical comparisons with a significance level set at 5%. RESULTS: Stereomicroscopic analysis showed more spirals and high helical angles in the Premium Taper Gold system. All sets of instruments had symmetrical spirals, no radial lands, no major defects, and an almost equiatomic ratio between nickel and titanium elements, while differences were observed in their tips' geometry and surface finishing. At room temperature (20 °C), DSC test revealed martensitic characteristics for ProTaper Gold and Go-Taper Flex, and mixed austenite plus R-phase for the Premium Taper Gold, while ProTaper Universal and U-Files had full austenitic characteristics. Overall, larger instruments had higher torque resistance and bending load values than smaller ones, while a lack of consistency and mixed values were observed in the angle of rotation. The 0.25/.08v and 0.30/.09v instruments of ProTaper Universal and U-File had the highest maximum torques, the lowest angles of rotation, and the highest bending loads than other tested systems (P < .05). No significant difference was noted regarding the untouched root canal walls after preparation with the tested systems (P > .05). CONCLUSIONS: Although differences observed in the overall geometry and phase transformation temperatures have influenced the results of mechanical tests, unprepared canal surface areas were equivalent among systems. CLINICAL RELEVANCE: Root canal preparation systems with similar geometries might present different mechanical behaviors but equivalent shaping ability.


Asunto(s)
Aleaciones Dentales , Preparación del Conducto Radicular , Aleaciones Dentales/química , Diseño de Equipo , Ensayo de Materiales , Metalurgia , Estrés Mecánico , Titanio/química
14.
Clin Oral Investig ; 24(11): 4109-4121, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32382930

RESUMEN

OBJECTIVES: To assess the internal and external morphologies of the mesiobuccal (MB) root of maxillary molars presenting a third root canal (MB3), using micro-computed tomography (micro-CT). MATERIAL AND METHODS: Two-hundred and sixty-five extracted maxillary first and second molars with different root configurations were imaged in a micro-CT scanner at 19.6-µm pixel size. Sixteen teeth presenting MB3 canal were selected and evaluated regarding root configuration, minimal dentine thickness 2 mm under the furcation area, canal configuration of the MB root, MB3 canal morphology (location, independent or confluent orifice, and anatomy types), and the apical anatomy (aspect ratio, number of accessory canals and foramina, presence of isthmus, and independent MB3 foramen). RESULTS: Overall, a high variability in canal configuration was detected in the MB root. MB3 canal was observed in 10 maxillary first molars and 6 maxillary second molars (n = 16). Minimal dentine thickness related to the MB3 canal at the coronal third was smaller than that of the MB1 canal. A complex internal anatomy comprising 13 different root canal configurations was observed. A high number of independent MB3 orifices at the pulp chamber floor was observed in the first molars (7 out of 10 teeth), while most of the specimens (n = 14) showed a confluent anatomy of the MB3 canal. A varied number of accessory canals and foramina were observed. At the apical third, isthmus could be observed in 6 specimens, while an independent MB3 foramen was present in 37.5% of the MB roots. CONCLUSIONS: MB3 canal is a rare anatomical variation present in maxillary first and second molars. Its presence can be associated to a complex internal anatomy of the MB root which includes the presence of isthmuses and multiple accessory canals and foramina at the apical third, but also a thin dentine thickness at the coronal third and a confluent anatomy of the MB3 with the other main canals.


Asunto(s)
Diente Molar , Raíz del Diente , Cavidad Pulpar/diagnóstico por imagen , Maxilar/diagnóstico por imagen , Diente Molar/diagnóstico por imagen , Raíz del Diente/diagnóstico por imagen , Microtomografía por Rayos X
15.
Clin Oral Investig ; 24(9): 3299-3305, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31965283

RESUMEN

OBJECTIVES: To assess C-shaped root canal configuration by identifying its prevalence and each configuration type proportion, according to tooth (mandibular first or second molar) and demographic characteristics in a Brazilian population, using cone-beam computed tomography (CBCT). Moreover, it was verified if there is a relationship between root canal configuration observed in two-dimensional reconstructions of CBCT and presence of C-shape. METHODS: Mandibular jaw CBCT scans (184 males and 220 females, aged 15 to 80 years), which presented 1464 mandibular molars (710 first molars and 754 second molars), were assessed. Teeth were evaluated for the presence and type of C-shaped root canals by observing the roots at five levels in CBCT axial reconstructions. Root canal configuration was assessed in panoramic reconstructions. Data were statistically analyzed at a significance level of 5%. RESULTS: Of the 1464 mandibular molars, 125 (8.5%) were classified as C-shaped. This variation was more prevalent in females (n = 107, 85.6%) and in second molars (n = 108, 86.4%). C1 (uninterrupted C-shaped canal) was the most prevalent type of C-shaped configuration (41.76%), while C5 (no canal lumen) was the least prevalent type (0.96%). Single root with single canal in panoramic reconstructions was the most predominant configuration for C-shaped teeth (n = 54, 43.2%). Fused roots presented 17.2 higher odds of being associated with C-shaped root canals than non-fused roots. CONCLUSIONS: C-shaped root canals were more prevalent in mandibular second molars and in females. Additionally, clinicians should bear in mind the greater possibility of C-shaped configuration in mandibular molars with fused roots. CLINICAL RELEVANCE: Mandibular molars with C-shaped canals present a clinical challenge. A higher C-shaped proportion was noted in radiographic fused root types, which had 17.2 higher odds of presenting such anatomy when compared to radiographic non-fused roots. Root radiographic features may help in diagnosis of complex C-shaped morphologies.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Cavidad Pulpar , Raíz del Diente , Brasil , Cavidad Pulpar/diagnóstico por imagen , Femenino , Humanos , Masculino , Mandíbula/diagnóstico por imagen , Diente Molar/diagnóstico por imagen , Prevalencia , Raíz del Diente/diagnóstico por imagen
17.
Clin Oral Investig ; 23(1): 107-112, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29536188

RESUMEN

OBJECTIVES: The purpose of this study was to determine the prevalence of the C-shaped root canal configuration, location of the longitudinal groove, sex differences, and unilateral/bilateral presence in mandibular first and second molars in a Saudi population using cone beam computed tomography (CBCT). MATERIALS AND METHODS: CBCT images for the mandibular first and second molars of 487 patients (a total of 529 first molars and 681 s molars) were evaluated. The teeth were assessed for the presence of C-shaped root canals according to Fan criteria. Subdivisions were also made according to sex, direction of the longitudinal groove, and unilateral/bilateral presence. RESULTS: Only one C-shaped mandibular first molar was observed (0.19%), whereas 62 second molars (9.1%) exhibited C-shaped anatomy. Unilateral presence of the C-shaped root canal system was more common (53.85%). Female patients had a higher prevalence than males. Longitudinal grooves were most commonly found on the root lingual surface (58.1%). CONCLUSIONS: The prevalence of the C-shaped canal configuration in a Saudi Arabian population was 0.19% in the mandibular first molar and 9.1% in the mandibular second molar. Longitudinal groove prevalence was highest on the lingual surface. Women had a significantly higher prevalence of the C-shaped canal configuration than men. Patients with unilateral presence of the C-shaped canal configuration were more common than those with bilateral presence. CLINICAL RELEVANCE: Tooth type, patient sex, and ethnicity can help clinicians predict the prevalence of the C-shaped canal system in mandibular molars.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Cavidad Pulpar/anatomía & histología , Cavidad Pulpar/diagnóstico por imagen , Diente Molar/anatomía & histología , Diente Molar/diagnóstico por imagen , Raíz del Diente/anatomía & histología , Raíz del Diente/diagnóstico por imagen , Adolescente , Adulto , Anciano , Niño , Femenino , Humanos , Masculino , Mandíbula/anatomía & histología , Mandíbula/diagnóstico por imagen , Persona de Mediana Edad , Estudios Retrospectivos , Arabia Saudita , Factores Sexuales
18.
J Prosthodont ; 27(7): 598-604, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27662604

RESUMEN

PURPOSE: This prospective clinical study evaluated the success rate of indirect composite resin cuspal coverage on endodontically treated molars and premolars and the survival rate of the restored teeth. MATERIALS AND METHODS: One hundred fifty endodontically treated teeth were restored with total resin cuspal coverage and randomly selected for the study. Patients were recalled after 2 to 5 years for clinical evaluation. Data were subjected to standard tests of statistical correlations using Spearman test. RESULTS: Out of the 150 teeth, 84 were molars and 66 were premolars. Of these teeth, 58.7% had mesio-occlusal-distal (MOD) cavities, 20.7% had mesio-occlusal (MO), and 20.7% had occlusal-distal (OD). A build-up procedure was performed in 51.3% of the teeth, and buccal veneer composite resins were placed at the margins of 96.7% of the teeth. Out of the 150 teeth, 30 (20%) presented margin discoloration, 3 teeth (2%) had restoration reparable fractures, 2 teeth (1.3%) had restoration irreparable fractures, and 1 tooth (0.7%) exhibited secondary recurrent caries. The opposing arch that occluded with the treated teeth presented 58% natural teeth (no restoration material), 26.7% ceramic crowns, and 15.3% implant-supported ceramic crowns. Statistically significant differences (p = 0.018) between irreparable restoration fractures and the type of support material present in the opposing arch were found. CONCLUSIONS: In a period of up to 5 years, the resin cuspal coverage of endodontic treated teeth had a success rate of 96%, while the tooth survival rate was 100%. The type of support material on the opposing arch may influence the longevity of the restoration of endodontically treated teeth.


Asunto(s)
Resinas Compuestas , Caries Dental/terapia , Restauración Dental Permanente/métodos , Diente no Vital/terapia , Adulto , Diente Premolar , Coronas con Frente Estético , Femenino , Humanos , Masculino , Diente Molar , Pronóstico , Estudios Prospectivos , Resultado del Tratamiento
19.
J Endod ; 50(1): 31-54, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37898333

RESUMEN

INTRODUCTION: This worldwide study examined the root and root canal characteristics of maxillary premolars and explored how demographic factors impact the outcomes. METHODS: Observers from 44 countries assessed 26,400 maxillary premolars using cone-beam computed tomography and employed a standardized screening method to gather data on multiple canal morphology and 3-rooted configuration (primary outcomes), as well as secondary outcomes related to root and root canal anatomies. Demographic factors such as ethnicity, sex, and age were collected for each participant. The intra- and inter-observer tests ensured observer reliability. Primary outcomes were represented as odds ratios and untransformed proportions accompanied by 95% confidence interval (CI) forest plots. Meta-analysis compared sub-groups and identified sources of heterogeneity (α = 5%). RESULTS: The overall prevalence of multiple canal morphology in the first premolar was 93.5% (95% CI, 93.3%-94.7%), while in the second premolar, it was 49.7% (95% CI, 44.9%-54.6%). The proportion of 3-rooted configuration was 1.8% (95% CI, 1.4%-2.1%) in the first premolar and 0.4% (95% CI, 0.3%-0.5%) in the second. Asian countries generally displayed fewer roots and root canals, while European nations showed higher counts (P < .05). Males exhibited higher percentages and odds ratios for both outcomes in both premolars. Younger patients demonstrated lower percentages of multiple root canal morphologies (P < .05). Factors such as tooth side, voxel size and field-of-view did not influence the outcomes (P > .05). CONCLUSIONS: The worldwide assessment of root and root canal characteristics of maxillary premolars has revealed a discernible influence of various factors such as tooth type, geographical region, ethnicity, sex, and age.


Asunto(s)
Cavidad Pulpar , Raíz del Diente , Masculino , Humanos , Cavidad Pulpar/diagnóstico por imagen , Cavidad Pulpar/anatomía & histología , Diente Premolar/diagnóstico por imagen , Diente Premolar/anatomía & histología , Estudios Transversales , Reproducibilidad de los Resultados , Raíz del Diente/diagnóstico por imagen , Raíz del Diente/anatomía & histología , Maxilar/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico/métodos , Estudios Multicéntricos como Asunto
20.
J Endod ; 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38936508

RESUMEN

INTRODUCTION: To evaluate the prevalence of single-root with a single root canal and four-root configurations in the maxillary first and second molars, and analyze how geographic region, ethnicity, sex, and age impact these outcomes. METHODS: Researchers from 44 nations examined 26,400 maxillary molars using cone-beam computed tomography scans to gather data on the proportions of single roots with single canals and four-root configurations. All observers underwent prior calibration regarding the step-by-step assessment protocol and anatomical concepts to ensure consistent evaluations across all assessed locations. Tests were conducted to evaluate the intra- and inter-observer reliability. Demographic data including ethnicity, gender, and age were collected for each participant. The potential impact of imaging voxel size and field-of-view on bias was also assessed. The primary results were depicted as odds ratios and untransformed proportion forest plots with 95% confidence intervals. Additionally, a meta-analysis was performed to compare various subgroups and identify sources of variation among them. Statistical significance was set at 5%. RESULTS: The prevalence of single-rooted with a single canal and four-rooted configurations in the maxillary first molar was 0.16% and 0.28%, respectively, while in the maxillary second molar, it was 2.56% and 0.83%. Males tended to exhibit lower percentages of single roots with a single canal (P < 0.05) and higher percentages of four-rooted configurations (P > 0.05) in the second molar, whereas the African subgroup displayed lower proportions for both configurations. Additionally, in both teeth, single roots with a single canal were more prevalent among older patients. Voxel size and field-of-view did not significantly influence the results (P > 0.05). CONCLUSIONS: The proportions of single-rooted with a single canal and four-rooted configurations were low, and demographic factors such as geographic region, ethnicity, sex, and age may have influenced the outcomes for the maxillary second molar.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA