Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 156
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 45(20): 1831-1839, 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38740526

RESUMEN

BACKGROUND AND AIMS: Arrhythmic mitral valve prolapse (AMVP) is linked to life-threatening ventricular arrhythmias (VAs), and young women are considered at high risk. Cases of AMVP in women with malignant VA during pregnancy have emerged, but the arrhythmic risk during pregnancy is unknown. The authors aimed to describe features of women with high-risk AMVP who developed malignant VA during the perinatal period and to assess if pregnancy and the postpartum period were associated with a higher risk of malignant VA. METHODS: This retrospective international multi-centre case series included high-risk women with AMVP who experienced malignant VA and at least one pregnancy. Malignant VA included ventricular fibrillation, sustained ventricular tachycardia, or appropriate shock from an implantable cardioverter defibrillator. The authors compared the incidence of malignant VA in non-pregnant periods and perinatal period; the latter defined as occurring during pregnancy and within 6 months after delivery. RESULTS: The authors included 18 women with AMVP from 11 centres. During 7.5 (interquartile range 5.8-16.6) years of follow-up, 37 malignant VAs occurred, of which 18 were pregnancy related occurring in 13 (72%) unique patients. Pregnancy and 6 months after delivery showed increased incidence rate of malignant VA compared to the non-pregnancy period (univariate incidence rate ratio 2.66, 95% confidence interval 1.23-5.76). CONCLUSIONS: The perinatal period could impose increased risk of malignant VA in women with high-risk AMVP. The data may provide general guidance for pre-conception counselling and for nuanced shared decision-making between patients and clinicians.


Asunto(s)
Prolapso de la Válvula Mitral , Complicaciones Cardiovasculares del Embarazo , Humanos , Femenino , Embarazo , Prolapso de la Válvula Mitral/complicaciones , Prolapso de la Válvula Mitral/epidemiología , Estudios Retrospectivos , Adulto , Complicaciones Cardiovasculares del Embarazo/epidemiología , Factores de Riesgo , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/etiología , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/etiología , Trastornos Puerperales/epidemiología , Trastornos Puerperales/etiología , Desfibriladores Implantables , Incidencia , Fibrilación Ventricular/epidemiología , Fibrilación Ventricular/etiología , Periodo Posparto
2.
J Cardiovasc Electrophysiol ; 35(1): 206-213, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38018417

RESUMEN

Left ventricular assist device (LVAD) implantation is an established treatment for patients with advanced heart failure refractory to medical therapy. However, the incidence of ventricular arrhythmias (VAs) is high in this population, both in the acute and delayed phases after implantation. About one-third of patients implanted with an LVAD will experience sustained VAs, predisposing these patients to worse outcomes and complicating patient management. The combination of pre-existing myocardial substrate and complex electrical remodeling after LVAD implantation account for the high incidence of VAs observed in this population. LVAD patients presenting VAs refractory to antiarrhythmic therapy and catheter ablation procedures are not rare. In such patients, treatment options are extremely limited. Stereotactic body radiation therapy (SBRT) is a technique that delivers precise and high doses of radiation to highly defined targets, reducing exposure to adjacent normal tissue. Cardiac SBRT has recently emerged as a promising alternative with a growing number of case series reporting the effectiveness of the technique in reducing the VA burden in patients with arrhythmias refractory to conventional therapies. The safety profile of cardiac SBRT also appears favorable, even though the current clinical experience remains limited. The use of cardiac SBRT for the treatment of refractory VAs in patients implanted with an LVAD are even more scarce. This review summarizes the clinical experience of cardiac SBRT in LVAD patients and describes technical considerations related to the implementation of the SBRT procedure in the presence of an LVAD.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Radiocirugia , Taquicardia Ventricular , Humanos , Radiocirugia/efectos adversos , Corazón Auxiliar/efectos adversos , Estudios Retrospectivos , Arritmias Cardíacas/cirugía , Insuficiencia Cardíaca/terapia , Resultado del Tratamiento , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/radioterapia , Taquicardia Ventricular/cirugía
3.
J Card Fail ; 2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38851449

RESUMEN

BACKGROUND: Prediction of outcomes remains an unmet need in LVAD candidates. Development of right heart failure portends an excess in mortality but imaging parameters of right ventricular systolic function have failed to demonstrate a prognostic role. By integrating pulmonary pressure, right ventriculoarterial coupling could fill this gap. METHODS: The ASSIST-ICD registry was used to test right ventriculoarterial coupling surrogate parameters at implantation for the prediction of all-cause mortality. RESULTS: The ratio of the tricuspid annular plane systolic excursion over the estimated systolic pulmonary pressure (TAPSE/sPAP) was not associated with long-term survival in univariate analysis (p = 0.89), neither was the pulmonary artery pulsatility index (PAPi) (p = 0.13). Conversely, the ratio of the right atrial pressure over the pulmonary capillary wedge pressure (RAP/PCWP) was associated with all-cause mortality (p <0.01). After taking tricuspid regurgitation severity, LVAD indication, LVAD model, age, blood urea nitrogen, and pulmonary vascular resistance into account, RAP/PCWP remained associated with survival (HR 1.35 [1.10 - 1.65], p <0.01). CONCLUSION: Among pre-implant RVAC surrogates, only RAP/PCWP was associated with long-term all-cause mortality in LVAD recipients. This association was independent of established risk factors.

4.
J Cardiovasc Electrophysiol ; 34(2): 270-278, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36434797

RESUMEN

INTRODUCTION: Pulmonary vein isolation (PVI) is effective at treating 50% of unselected patients with persistent atrial fibrillation (AF). Alternatively, PVI combined with a new ablation strategy entitled the Marshall-PLAN ensures a 78% 1-year sinus rhythm (SR) maintenance rate in the same population. However, a substantial subset of patients could undergo the Marshall-PLAN unnecessarily. It is therefore essential to identify those patients who can be treated with PVI alone versus those who may truly benefit from the Marshall-PLAN before ablation is performed. In this context, we hypothesized that electrical cardioversion (EC) could help to select the most appropriate strategy for each patient. METHODS: In this multicentre, prospective, randomized study, patients with AF recurrence within 4 weeks after EC will be randomized 1:1 to PVI alone or the Marshall-PLAN. Conversely, patients in whom SR is maintained for ≥4 weeks after EC will be treated with PVI only and included in a prospective registry. The primary endpoint will be the 1-year SR maintenance rate after a single ablation procedure. RESULTS AND CONCLUSION: The Marshall-PLAN might be necessary in patients with an advanced degree of persistent AF (i.e., where SR is not maintained for ≥4 uninterrupted weeks after EC). Conversely, in patients with mild or moderate persistent AF (i.e., where SR is maintained for ≥4 weeks after EC), PVI alone might be a sufficient ablation strategy. The PACIFIC trial is the first study designed to assess whether rhythm monitoring after EC could help to identify patients who should undergo adjunctive ablation strategies beyond PVI.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Cardioversión Eléctrica/efectos adversos , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
5.
J Cardiovasc Electrophysiol ; 34(2): 389-399, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36335623

RESUMEN

INTRODUCTION: Scar-related ventricular tachycardia (VT) usually results from an underlying reentrant circuit facilitated by anatomical and functional barriers. The later are sensitive to the direction of ventricular activation wavefronts. We aim to evaluate the impact of different ventricular activation wavefronts on the functional electrophysiological properties of myocardial tissue. METHODS: Patients with ischemic heart disease referred for VT ablation underwent high-density mapping using Carto®3 (Biosense Webster). Maps were generated during sinus rhythm, right and left ventricular pacing, and analyzed using a new late potential map software, which allows to assess local conduction velocities and facilitates the delineation of intra-scar conduction corridors (ISCC); and for all stable VTs. RESULTS: In 16 patients, 31 high-resolution substrate maps from different ventricular activation wavefronts and 7 VT activation maps were obtained. Local abnormal ventricular activities (LAVAs) were found in VT isthmus, but also in noncritical areas. The VT isthmus was localized in areas of LAVAs overlapping surface between the different activation wavefronts. The deceleration zone location differed depending on activation wavefronts. Sixty-six percent of ISCCs were similarly identified in all activating wavefronts, but the one acting as VT isthmus was simultaneously identified in all activation wavefronts in all cases. CONCLUSION: Functional based substrate mapping may improve the specificity to localize the most arrhythmogenic regions within the scar, making the use of different activation wavefronts unnecessary in most cases.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Cicatriz/diagnóstico , Cicatriz/etiología , Técnicas Electrofisiológicas Cardíacas , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía , Arritmias Cardíacas/cirugía , Frecuencia Cardíaca , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
6.
BMC Pregnancy Childbirth ; 23(1): 18, 2023 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-36627576

RESUMEN

BACKGROUND: The assessment of clinical prognosis of pregnant COVID-19 patients at hospital presentation is challenging, due to physiological adaptations during pregnancy. Our aim was to assess the performance of the ABC2-SPH score to predict in-hospital mortality and mechanical ventilation support in pregnant patients with COVID-19, to assess the frequency of adverse pregnancy outcomes, and characteristics of pregnant women who died. METHODS: This multicenter cohort included consecutive pregnant patients with COVID-19 admitted to the participating hospitals, from April/2020 to March/2022. Primary outcomes were in-hospital mortality and the composite outcome of mechanical ventilation support and in-hospital mortality. Secondary endpoints were pregnancy outcomes. The overall discrimination of the model was presented as the area under the receiver operating characteristic curve (AUROC). Overall performance was assessed using the Brier score. RESULTS: From 350 pregnant patients (median age 30 [interquartile range (25.2, 35.0)] years-old]), 11.1% had hypertensive disorders, 19.7% required mechanical ventilation support and 6.0% died. The AUROC for in-hospital mortality and for the composite outcome were 0.809 (95% IC: 0.641-0.944) and 0.704 (95% IC: 0.617-0.792), respectively, with good overall performance (Brier = 0.0384 and 0.1610, respectively). Calibration was good for the prediction of in-hospital mortality, but poor for the composite outcome. Women who died had a median age 4 years-old higher, higher frequency of hypertensive disorders (38.1% vs. 9.4%, p < 0.001) and obesity (28.6% vs. 10.6%, p = 0.025) than those who were discharged alive, and their newborns had lower birth weight (2000 vs. 2813, p = 0.001) and five-minute Apgar score (3.0 vs. 8.0, p < 0.001). CONCLUSIONS: The ABC2-SPH score had good overall performance for in-hospital mortality and the composite outcome mechanical ventilation and in-hospital mortality. Calibration was good for the prediction of in-hospital mortality, but it was poor for the composite outcome. Therefore, the score may be useful to predict in-hospital mortality in pregnant patients with COVID-19, in addition to clinical judgment. Newborns from women who died had lower birth weight and Apgar score than those who were discharged alive.


Asunto(s)
COVID-19 , Mortalidad Hospitalaria , Respiración Artificial , Adulto , Femenino , Humanos , Recién Nacido , Embarazo , Peso al Nacer , Brasil/epidemiología , COVID-19/mortalidad , COVID-19/terapia , Hipertensión Inducida en el Embarazo , Pronóstico , Estudios Retrospectivos
7.
Eur Heart J ; 43(47): 4887-4896, 2022 12 14.
Artículo en Inglés | MEDLINE | ID: mdl-36303402

RESUMEN

AIMS: Sudden cardiac arrest remains a major complication of acute myocardial infarction (AMI) and is frequently related to ventricular fibrillation (VF). Incidence and impact of VF among patients hospitalized for AMI were evaluated. METHODS AND RESULTS: Data from the FAST-MI programme consisting of 5 French nationwide prospective cohort studies between 1995 and 2015 were analysed, totally including 14 423 patients with AMI (66 ± 14 years, 72% males, 59% ST-elevation myocardial infarction). Overall, proportion of patients presenting in-hospital VF decreased from 3.9% in 1995 to 1.8% in 2015 (P < 0.001). One-year mortality decreased from 60.7% to 24.6% (P < 0.001). However, compared with patients who did not develop VF, the over-risk of 1-year mortality associated with VF was stable over time [hazard ratio (HR) 6.78, 95% confidence interval (CI) 5.03-9.14 in 1995 and HR 6.64, 95% CI 4.20-10.49 in 2015, P = 0.52]. This increased mortality in the VF group was mainly related to fatal events occurring prior to hospital discharge, representing 86.2% of 1-year mortality, despite the very low rate of implantable cardioverter defibrillator in the VF group (2.6%). CONCLUSION: This study demonstrates that in-hospital VF incidence and mortality in the setting of AMI have significantly decreased over the past 20 years. Nevertheless, VF remained steadily associated with approximately a 10-fold increased relative risk of in-hospital mortality, without an impact on post-discharge mortality. Beyond long-term cardiac defibrillation strategy, these results emphasize the need to identify in-hospital interventions to further reduce mortality in VF patients. STUDY REGISTRATION: ClinicalTrials.gov Identifier: NCT00673036, NCT01237418, NCT02566200.


Asunto(s)
Infarto del Miocardio , Fibrilación Ventricular , Masculino , Humanos , Femenino , Fibrilación Ventricular/epidemiología , Fibrilación Ventricular/etiología , Fibrilación Ventricular/terapia , Estudios Prospectivos , Cuidados Posteriores , Alta del Paciente , Infarto del Miocardio/complicaciones , Infarto del Miocardio/epidemiología , Infarto del Miocardio/terapia , Factores de Riesgo
8.
Crit Care Med ; 50(5): e426-e433, 2022 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-34974497

RESUMEN

OBJECTIVES: Temporary circulatory support (TCS) as a bridge-to-left ventricular assist device (BTL) in cardiogenic shock patients has been increasing, but limited data exists on this BTL strategy. We aimed at analyzing the outcome of BTL patients in a population of cardiogenic shock patients compared with those without TCS at the time of the left ventricular assist device (LVAD) surgery and identify predictors of postoperative mortality in this specific population. DESIGN: A multicenter retrospective observational study conducted in 19 centers from 2006 to 2016. SETTING: Nineteen French centers. PATIENTS: A total of 329 cardiogenic shock patients at the time of LVAD implantation were analyzed. Patients were divided in three groups: those under TCS at the time of LVAD implantation (n = 173), those with TCS removal before LVAD surgery (n = 24), and those who did not undergo a bridging strategy (n = 152). Primary endpoint was 30-day mortality. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Among the BTL group, 68 (39.3%), 18 (10.4%), and 15 (8.7%) patients were under venoarterial extracorporeal membrane oxygenation, Impella, and IABP support alone, and 72 patients (20.6%) were under multiple TCS support. BTL patients presented similar 30 days survival compared with the TCS removal and non-BTL groups. However, BTL group had a significantly longer ICU duration stay, with two-fold duration of mechanical ventilation time, but the three groups experienced similar postoperative complications. Multivariate analysis identified three independent predictors of mortality in the BTL group: combined surgery with LVAD, body mass index (BMI), and heart failure (HF) duration. BTL strategy was not an independent predictor of mortality in cardiogenic shock patients who underwent LVAD. CONCLUSIONS: BTL strategy is not associated with a lower survival among cardiogenic shock patients with LVAD implantation. Predictors of mortality are combined surgery with LVAD, higher BMI, and HF duration.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca , Corazón Auxiliar , Oxigenación por Membrana Extracorpórea/efectos adversos , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Estudios Retrospectivos , Choque Cardiogénico/etiología , Choque Cardiogénico/cirugía , Resultado del Tratamiento
9.
Europace ; 24(10): 1675-1683, 2022 10 13.
Artículo en Inglés | MEDLINE | ID: mdl-35951747

RESUMEN

AIMS: Sports practice, especially in competition, is usually restrained in patients diagnosed with long QT syndrome (LQTS). Although data are scarce, a low incidence of cardiac arrhythmic events (CAEs) during sports practice is reported. We aim to evaluate the incidence of CAE during sports practice in LQTS patients. METHODS AND RESULTS: All consecutive patients above 18 years of age diagnosed with LQTS and prospectively followed at the referral centre for inherited arrhythmia syndrome received a survey to retrospectively assess their sports practice prior to and after the diagnosis of LQTS. Two hundred and forty-six patients were included (57% females). The median age was 43 years, and the median QTc was 457 ms (428; 482). Patients reported a total of 4092 years [1376 (34%) after diagnosis] of sports practice: 2905 (77%) [1138 (39%) after diagnosis] years of leisure practice and 1187 (23%) [238 (20%) after diagnosis] years of competitive practice. One hundred and eighty (73%) patients practiced sport prior to the diagnosis of LQTS and 170 (69%) after. Prior to the diagnosis, four (2%) patients presented a CAE during leisure sports practice and one during competition. After diagnosis, only one patient presented a CAE, appropriately treated by an implantable cardioverter defibrillator discharge, in the context of beta-blocker non-compliance. The CAE event rate was 0.0007 events/year in the 1376 years of total sports practice after the diagnosis of LQTS. CONCLUSION: After the diagnosis of LQTS, the occurrence of CAE is very low during sports practice, even in competitive practice. There was no CAE in patients properly treated with beta-blocker therapy with good compliance.


Asunto(s)
Desfibriladores Implantables , Síndrome de QT Prolongado , Deportes , Adulto , Desfibriladores Implantables/efectos adversos , Electrocardiografía , Femenino , Humanos , Síndrome de QT Prolongado/diagnóstico , Síndrome de QT Prolongado/epidemiología , Síndrome de QT Prolongado/terapia , Masculino , Estudios Retrospectivos
10.
Neurol Sci ; 43(6): 3759-3768, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35091884

RESUMEN

OBJECTIVE: We developed a detailed imaging phenotype of the cerebral complications in critically ill patients with infective endocarditis (IE) and determine whether any specific imaging pattern could impact prognostic information. METHODS: One hundred ninety-two patients admitted to the intensive care units of seven tertiary centers with severe, definite left IE and neurological complications were included. All underwent cerebral imaging few days after admission to define the types of lesions, their volumes, and their locations using voxel-based lesion-symptom mapping (VLSM). We employed uni- and multi-variate logistic regression analyses to explore the associations among imaging features and other prognostic variables and the 6-month modified Rankin Scale (mRS) score. RESULTS: Ischemic lesions were the most common lesions (75%; mean volume, 15.3 ± 33 mL) followed by microbleeds (50%; mean number, 4 ± 7.5), subarachnoidal hemorrhages (20%), hemorrhagic strokes (16%; mean volume, 14.6 ± 21 mL), and hemorrhagic transformations (10%; mean volume, 5.6 ± 11 mL). The volume of hemorrhagic transformations, the severity of leukopathy, and the compromises of certain locations on the motor pathway from the VLSM were associated with a poor 6-month mRS score on univariate analyses. However, upon multivariate analyses, no such specific imaging pattern independently predicted the mRS; this was instead influenced principally by age (OR = 1.03 [1.004-1.06]) and cardiac surgery status (OR = 0.06 [0.02-0.16]) in the entire cohort, and by age (OR = 1.04 [1.01-1.08]) and Staphylococcus aureus status (OR = 2.86 [1.19-6.89]) in operated patients. CONCLUSIONS: In a cohort of severely ill IE patients with neurological complications, no specific imaging pattern could be highlighted as a reliable predictor of prognosis.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Enfermedades del Sistema Nervioso , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Endocarditis/complicaciones , Endocarditis/diagnóstico por imagen , Endocarditis Bacteriana/complicaciones , Endocarditis Bacteriana/diagnóstico por imagen , Humanos , Enfermedades del Sistema Nervioso/complicaciones , Neuroimagen , Pronóstico , Factores de Riesgo , Resultado del Tratamiento
11.
J Cardiovasc Electrophysiol ; 32(11): 2943-2952, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34455655

RESUMEN

INTRODUCTION: The distance from the descending aorta (DA) to the posterior wall of the left atrium (LA) is variable. We aimed to determine whether the proximity between the DA and the left inferior pulmonary vein (LIPV) ostium has an impact on biophysical parameters and cryoballoon (CB) ablation efficacy during LIPV freezing. METHODS: Patients referred for CB-ablation of atrial fibrillation (AF) in two high-volume centers were included. Cryoablation data were collected prospectively for each patient. The anatomical relationships between the LIPV and the DA (distance LIPV ostium-DA, presence of an aortic imprint on the posterior aspect of the LIPV) were then retrospectively analysed on the LA computed tomography scans realized before AF ablation. RESULTS: A total of 350 patients were included (70% men, 59.7 ± 11.5 years). The decrease in the Ostium-DA distance was significantly correlated to the increase in the time-to-isolation (TTI) (r = -.31; p = .036), with less negative temperature (r = -.11; p = .045). Similarly, the presence of an aortic imprint on the LIPV was associated with a longer TTI (p < .001). The analysis of redo procedures data shows a trend toward the presence of shorter ostium-DA distances (15.3 ± 3.29 vs. 18.1 ± 4.99, p = .15) and more frequent aortic imprints (63.6% vs. 47.5%, p = .34) in patients with LIPV reconnection as opposed to patients without reconnection in the LIPV. CONCLUSION: Our findings indicated that the DA seems to have a "radiator" effect influencing LIPV cryoablation parameters during CB-ablation. Additional studies will be needed to elucidate whether this biophysical influence has a clinical impact in LIPVs reconnections.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Anciano , Aorta Torácica , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
12.
J Cardiovasc Electrophysiol ; 32(2): 515-522, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33270307

RESUMEN

OBJECTIVES: This study sought to validate the performance of the VT-LVAD risk model in predicting late ventricular arrhythmias (VAs) in patients after left ventricular assist device (LVAD) implantation. BACKGROUND: The need for implantable cardioverter-defibrillator (ICD)-implantation in LVAD recipients is not well studied. A better selection of the patients with high risk for late VAs could lead to a more targeted ICD-implantation or replacement. METHODS: The study evaluated the performance of the VT-LVAD prognostic score (VAs prior LVAD, no ACE-inhibitor in medication, heart failure duration > 12 months, early VAs post-LVAD implantation, atrial fibrillation prior LVAD, idiopathic dilated cardiomyopathy) for the endpoint of the occurrence of late VAs in 357 LVAD patients in Heart Centre of Leipzig. RESULTS: From the initial 460 patients, 357 (age: 58 ± 10 years; left ventricular ejection fraction: 20 ± 6%; HeartWare: 50%; HeartMate III: 42%) were assigned to four risk groups according to their VT-LVAD score varying from low risk to very high risk. After 25 months, late VAs occurred in 130 patients. The VT-LVAD score was an independent predictor of late VAs (multivariate analysis; p = < .001; goodness-of-tip p = .347; odds ratio: 4.8). While there was no statistically significant difference between the low- and intermediate-risk group, risk stratification for patients with high risk and very high risk performed more accurately (pairwise comparison p = .005 and p < .001, respectively). CONCLUSIONS: The VT-LVAD score predicted accurately the occurrence of late VAs in high-risk LVAD recipients in a large external cohort of LVAD recipients supporting its utility for more targeted ICD implantations.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Corazón Auxiliar , Taquicardia Ventricular , Anciano , Arritmias Cardíacas , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Corazón Auxiliar/efectos adversos , Humanos , Persona de Mediana Edad , Estudios Retrospectivos
13.
J Cardiovasc Electrophysiol ; 32(9): 2522-2527, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34270153

RESUMEN

BACKGROUND: Temporary transvenous pacing in critically ill patients requiring prolonged cardiac pacing is associated with a high risk of complications. We sought to evaluate the safety and efficacy of self-contained intracardiac leadless pacemaker (LPM) implantation in this population. METHODS AND RESULTS: Consecutive patients implanted with a Micra LPM during the hospitalization in an intensive care unit were retrospectively included. Inclusion criteria were: more than or equal to 1 supracaval central venous line, or a ventilation tube, or intravenous antibiotic therapy for ongoing sepsis or bacteremia. Patients with a history of the previous implantation of a pacemaker were excluded. Out of 1016 patients implanted with an LPM, 99 met the inclusion criteria. Mean age was 75 years and Charlson comorbidity index 7. LPM implantation was successfully performed in 98% of cases, with a perioperative complication rate of 5%, mainly cardiac injuries. In-hospital mortality rate was 6%. No late (>30 days) device-related complication occurred, especially no infection. CONCLUSIONS: LPM appears as an acceptable alternative to conventional temporary transvenous pacing in selected critically ill patients requiring prolonged cardiac pacing, especially regarding the risk of infection.


Asunto(s)
Enfermedad Crítica , Marcapaso Artificial , Anciano , Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial/efectos adversos , Diseño de Equipo , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
14.
Infection ; 49(5): 999-1006, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34089482

RESUMEN

BACKGROUND: Increasing use of cardiovascular implantable electronic devices (CIED), as permanent pacemakers (PPM), implantable cardioverter defibrillators (ICD), or cardiac resynchronization therapy (CRT), is associated with the emergence of CIED-related infective endocarditis (CIED-IE). We aimed to characterize CIED-IE profile, temporal trends, and prognostic factors. METHODS: CIED-IE diagnosed at Rennes University Hospital during years 1992-2017 were identified through computerized database, and included if they presented all of the following: (1) clinical signs of infection; (2) microbiological documentation through blood and/or CIED lead cultures; (3) lead or valve vegetation, or definite IE according to Duke criteria. Data were retrospectively extracted from medical charts. The cohort was categorized in three periods: 1992-1999, 2000-2008, and 2009-2017. RESULTS: We included 199 patients (51 women, 148 men, median age 73 years [interquartile range, 64-79]), with CIED-IE: 158 PPMs (79%), 24 ICD (12%), and 17 CRT (9%). Main pathogens were coagulase-negative staphylococci (CoNS: n = 86, 43%), Staphylococcus aureus (n = 60, 30%), and other Gram-positive cocci (n = 28, 14%). Temporal trends were remarkable for the decline in CoNS (P = 0.002), and the emergence of S. aureus as the primary cause of CIED-IE (24/63 in 2009-2017, 38%). Factors independently associated with one-year mortality were chronic obstructive pulmonary disease (COPD: hazard ratio 3.84 [1.03-6.02], P = 0.03), left-sided endocarditis (HR 2.25 [1.09-4.65], P = 0.03), pathogens other than CoNS (HR 3.16 [1.19-8.39], P = 0.02), and CIED removal/reimplantation (HR 0.41 [0.20-0.83], P = 0.01). CONCLUSIONS: S. aureus has emerged as the primary cause of CIED-IE. Left-sided endocarditis, COPD, pathogens other than CoNS, and no CIED removal/reimplantation are independent risk factors for one-year mortality.


Asunto(s)
Desfibriladores Implantables , Endocarditis Bacteriana , Endocarditis , Infecciones Relacionadas con Prótesis , Anciano , Desfibriladores Implantables/efectos adversos , Endocarditis/epidemiología , Endocarditis/etiología , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Femenino , Humanos , Masculino , Infecciones Relacionadas con Prótesis/epidemiología , Estudios Retrospectivos , Staphylococcus aureus
15.
Europace ; 23(9): 1428-1436, 2021 09 08.
Artículo en Inglés | MEDLINE | ID: mdl-34427302

RESUMEN

AIMS: The roles of implantable cardioverter-defibrillators (ICDs) and radiofrequency catheter ablation (RCA) in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC) and well-tolerated monomorphic ventricular tachycardia (MVT) are debated. In this multicentre retrospective study, we aimed at reporting the outcome of selected patients with ARVC after RCA without a back-up ICD. METHODS AND RESULTS: Patients with ARVC who underwent RCA of well-tolerated MVT at 10 tertiary centres across 5 countries, without an ICD before and 3 months after RCA, without syncope or electrical storm, and with left ventricular ejection fraction ≥50% were included. In total, 65 ARVC patients [mean age 44.5 ± 13.2 years, 78% males] underwent RCA of MVT between 2003 and 2016. Clinical presentation was palpitations in 51 (80%) patients. One (2%) patient had >1 clinical MVT. At the ablative procedure, clinical MVTs (mean rate 185 ± 32 b.p.m.) were inducible in 50 (81%) patients. Epicardial ablation was performed in 19 (29%) patients. Complete acute success was achieved in 47 (72%) patients. After a median follow-up of 52.4 months (range 12.3-171.4), there was no death or aborted cardiac arrest, and VT recurred in 19 (29%) patients. Survival without VT recurrence was estimated at 88%, 80%, and 68%, 12, 36, and 60 months after RCA, respectively, and was significantly associated with the approach and the procedural outcome. CONCLUSION: In patients with ARVC, well-tolerated MVT without a back-up ICD did not lead to fatal arrhythmic event after RCA despite VT recurrences in some. Our data suggest that RCA may be an alternative to ICD in selected ARVC patients.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica , Ablación por Catéter , Desfibriladores Implantables , Taquicardia Ventricular , Adulto , Displasia Ventricular Derecha Arritmogénica/complicaciones , Displasia Ventricular Derecha Arritmogénica/diagnóstico , Displasia Ventricular Derecha Arritmogénica/terapia , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Volumen Sistólico , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/terapia , Resultado del Tratamiento , Función Ventricular Izquierda
17.
Europace ; 22(3): 401-411, 2020 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-31865389

RESUMEN

AIMS: Up to 30% of selected heart failure patients do not benefit clinically from cardiac resynchronization therapy (CRT). Left ventricular (LV) wall thickness (WT) analysed using computed tomography (CT) has rarely been evaluated in response to CRT and mitral regurgitation (MR) improvement. We examined the association of LVWT and the ability to reverse LV remodelling and MR improvement after CRT. METHODS AND RESULTS: Fifty-four patients scheduled for CRT underwent pre-procedural CT. Reduced LVWT was defined as WT <6 mm and quantified as a percentage of total LV area. Endpoints were 6-month clinical and echocardiographic response to CRT [New York Heart Association (NYHA) class, LV ejection fraction (LVEF), LV end-diastolic volume (LVEDV), and LV end-systolic volume (LVESV)], MR improvement and 2-year major adverse cardiac events (MACE). Patients were divided into three groups according to the percentage of LVWT <6 mm area: ≤20%, 20-50%, and ≥50%. At 6 months, 75%, 71%, and 42% of the patients experienced NYHA improvement in the ≤20%, 20-50%, and ≥50% group, respectively. Additionally, ≤20% group presented higher LVEF, LVEDV, and LVESV positive response rate (86%, 59%, and 83%, respectively). Both 20-50% and ≥50% groups exhibited a lower LVEF, LVEDV, and LVESV positive response rate (52% and 42%; 47% and 45%; and 53% and 45%, respectively). Additionally, ≥25% of LVWT <6 mm inclusive of at least one papillary muscle insertion was the only predictor of lack of MR improvement. Lastly, ≥50% group experienced significantly lower 2-year MACE survival free probability. CONCLUSION: WT evaluated using CT could help to stratify the response to CRT and predict MR improvement and outcomes. CLINICAL TRIAL REGISTRATION: NCT01097733.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Volumen Sistólico , Tomografía , Resultado del Tratamiento , Función Ventricular Izquierda , Remodelación Ventricular
18.
Pacing Clin Electrophysiol ; 43(11): 1309-1317, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32627211

RESUMEN

BACKGROUND: Implantable cardioverter-defibrillator (ICD) lead dysfunction has been reported after left ventricular assist device (LVAD) implantation in limited single-center studies. We aimed at describing and characterizing the incidence of ICD lead parameters dysfunction after LVAD implantation. METHODS: Among the 652 patients enrolled in the ASSIST-ICD study, only patients with an ICD prior to LVAD were included (n = 401). ICD lead parameters dysfunction following LVAD implantation is defined as follows: (a) >50% decrease in sensing threshold, (b) pacing lead impedance increase/decrease by >100Ω, and (c) >50% increase in pacing threshold. RESULTS: One hundred twenty-two patients with an ICD prior to LVAD had available ICD interrogation reports prior and after LVAD. A total of 67 (55%) patients exhibited at least one significant lead dysfunction: 17 (15%) exhibited >50% decrease in right ventricular (RV) sensing, 51 (42%) had >100 Ω increase/decrease in RV pacing impedance, and 24 (20%) experienced >50% increase in RV pacing threshold. A total of 52 patients experienced ventricular arrhythmia during follow-up and all were successfully detected and treated by the device. All lead dysfunction could be managed conservatively. CONCLUSION: More than 50% of LVAD-recipients may experience >1 significant change in lead parameters but none had severe clinical consequences.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Electrodos Implantados/efectos adversos , Corazón Auxiliar , Anciano , Francia , Humanos , Masculino , Persona de Mediana Edad , Falla de Prótesis
19.
Curr Heart Fail Rep ; 17(4): 116-124, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32506301

RESUMEN

PURPOSE OF THE REVIEW: Patients with cardiomyopathy and impaired left ventricular (LV) ejection fraction are at risk of sudden cardiac death (SCD). In selected heart failure patients, cardiac resynchronization therapy (CRT) provides LV reverse remodeling and improves the cellular and molecular function leading to a reduced risk of ventricular arrhythmia and SCD. Consequently, some CRT candidates may not need concomitant ICD therapy. This review aimed at focusing on the residual risk of SCD in patients receiving CRT and discussing the requirement of a concomitant ICD therapy in CRT candidates. RECENT FINDINGS: New imaging diagnostic tools may be helpful to accurately predict patient with a residual risk of SCD and who required a CRT-D implantation. Recent data highlighted that cardiac computed tomography (CT) or myocardial scar tissue analysis using contrast-enhanced cardiac magnetic resonance (CMR) was able to predict the occurrence of VA in patients with bi-ventricular pacing. Cardiac imaging and specifically myocardial scar analysis seem promising to evaluate the risk of SCD following bi-ventricular pacing and will probably be of great help in the future to accurately identify those who needs concomitant defibrillator's protection.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Cardiomiopatías/complicaciones , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Marcapaso Artificial , Volumen Sistólico/fisiología , Remodelación Ventricular , Cardiomiopatías/fisiopatología , Cardiomiopatías/terapia , Muerte Súbita Cardíaca/etiología , Humanos , Función Ventricular Izquierda/fisiología
20.
Am Heart J ; 214: 69-76, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31174053

RESUMEN

BACKGROUND: Left ventricular assist device (LVAD)-associated infections may be life-threatening and impact patients' outcome. We aimed to identify the characteristics, risk factors, and prognosis of LVAD-associated infections. METHODS: Patients included in the ASSIST-ICD study (19 centers) were enrolled. The main outcome was the occurrence of LVAD-associated infection (driveline infection, pocket infection, or pump/cannula infection) during follow-up. RESULTS: Of the 652 patients enrolled, 201 (30.1%) presented a total of 248 LVAD infections diagnosed 6.5 months after implantation, including 171 (26.2%), 51 (7.8%), and 26 (4.0%) percutaneous driveline infection, pocket infection, or pump/cannula infection, respectively. Patients with infections were aged 58.7 years, and most received HeartMate II (82.1%) or HeartWare (13.4%). Most patients (62%) had implantable cardioverter-defibrillators (ICDs) before LVAD, and 104 (16.0%) had ICD implantation, extraction, or replacement after the LVAD surgery. Main pathogens found among the 248 infections were Staphylococcus aureus (n = 113' 45.4%), Enterobacteriaceae (n = 61; 24.6%), Pseudomonas aeruginosa (n = 34; 13.7%), coagulase-negative staphylococci (n = 13; 5.2%), and Candida species (n = 13; 5.2%). In multivariable analysis, HeartMate II (subhazard ratio, 1.56; 95% CI, 1.03 to 2.36; P = .031) and ICD-related procedures post-LVAD (subhazard ratio, 1.43; 95% CI, 1.03-1.98; P = .031) were significantly associated with LVAD infections. Infections had no detrimental impact on survival. CONCLUSIONS: Left ventricular assist device-associated infections affect one-third of LVAD recipients, mostly related to skin pathogens and gram-negative bacilli, with increased risk with HeartMate II as compared with HeartWare, and in patients who required ICD-related procedures post-LVAD. This is a plea to better select patients needing ICD implantation/replacement after LVAD implantation.


Asunto(s)
Infecciones Relacionadas con Catéteres/etiología , Corazón Auxiliar/efectos adversos , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Catéteres/epidemiología , Infecciones Relacionadas con Catéteres/microbiología , Infecciones Relacionadas con Catéteres/mortalidad , Desfibriladores Implantables/estadística & datos numéricos , Remoción de Dispositivos/estadística & datos numéricos , Femenino , Francia/epidemiología , Ventrículos Cardíacos , Corazón Auxiliar/estadística & datos numéricos , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Pronóstico , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/mortalidad , Estudios Retrospectivos , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA