Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Dig Endosc ; 36(1): 51-58, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37953649

RESUMEN

OBJECTIVES: Colonoscopy withdrawal times are associated with the adenoma detection rate (ADR). However, the relationship between ADR and cecal insertion time has been inadequately characterized. We aimed to evaluate endoscopist-related factors involved in the ADR, including the average individual colonoscopy insertion and withdrawal times. METHODS: This observational study used a colonoscopy database with pathology data from routine clinical practice in Japanese institutions. The odds ratios (OR) of endoscopist-related factors related to ADRs were examined using a generalized linear mixed model. RESULTS: Of the 186,293 colonoscopies performed during the study period, 47,705 colonoscopies by 189 endoscopists in four hospitals were analyzed for ADR. The overall ADR was 38.3% (95% confidence interval [CI] 37.8, 38.7). Compared to endoscopists with mean cecal insertion times of <5 min, the OR of ADR for those with mean cecal insertion times of 5-9, 10-14, and ≥15 min were 0.84 (95% CI 0.71, 0.99), 0.68 (95% CI 0.52, 0.90), and 0.45 (95% CI 0.25, 0.78), respectively. Compared to endoscopists with mean withdrawal times of <6 min, the OR of ADR for those with mean withdrawal times of 6-9, 10-14, and ≥15 min were 1.38 (95% CI 1.03, 1.85), 1.48 (95% CI 1.09, 2.02), and 1.68 (95% CI 1.04, 2.61), respectively. There were no significant differences in ADRs by endoscopist specialty, gender, or the total number of examinations performed. CONCLUSION: Individual mean colonoscopy insertion time was associated with ADR and might be considered as a colonoscopy quality indicator as well as withdrawal time.


Asunto(s)
Adenoma , Neoplasias Colorrectales , Humanos , Neoplasias Colorrectales/diagnóstico , Colonoscopía , Adenoma/diagnóstico , Factores de Tiempo , Bases de Datos Factuales , Detección Precoz del Cáncer
2.
Gastroenterology ; 163(1): 84-96.e2, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35339464

RESUMEN

BACKGROUND & AIMS: Despite the significant advances made in the diagnosis and treatment of Barrett's esophagus (BE), there is still a need for standardized definitions, appropriate recognition of endoscopic landmarks, and consistent use of classification systems. Current controversies in basic definitions of BE and the relative lack of anatomic knowledge are significant barriers to uniform documentation. We aimed to provide consensus-driven recommendations for uniform reporting and global application. METHODS: The World Endoscopy Organization Barrett's Esophagus Committee appointed leaders to develop an evidence-based Delphi study. A working group of 6 members identified and formulated 23 statements, and 30 internationally recognized experts from 18 countries participated in 3 rounds of voting. We defined consensus as agreement by ≥80% of experts for each statement and used the Grading of Recommendations, Assessment, Development and Evaluations (GRADE) tool to assess the quality of evidence and the strength of recommendations. RESULTS: After 3 rounds of voting, experts achieved consensus on 6 endoscopic landmarks (palisade vessels, gastroesophageal junction, squamocolumnar junction, lesion location, extraluminal compressions, and quadrant orientation), 13 definitions (BE, hiatus hernia, squamous islands, columnar islands, Barrett's endoscopic therapy, endoscopic resection, endoscopic ablation, systematic inspection, complete eradication of intestinal metaplasia, complete eradication of dysplasia, residual disease, recurrent disease, and failure of endoscopic therapy), and 4 classification systems (Prague, Los Angeles, Paris, and Barrett's International NBI Group). In round 1, 18 statements (78%) reached consensus, with 12 (67%) receiving strong agreement from more than half of the experts. In round 2, 4 of the remaining statements (80%) reached consensus, with 1 statement receiving strong agreement from 50% of the experts. In the third round, a consensus was reached on the remaining statement. CONCLUSIONS: We developed evidence-based, consensus-driven statements on endoscopic landmarks, definitions, and classifications of BE. These recommendations may facilitate global uniform reporting in BE.


Asunto(s)
Esófago de Barrett , Neoplasias Esofágicas , Esófago de Barrett/diagnóstico , Esófago de Barrett/patología , Esófago de Barrett/terapia , Brasil , Consenso , Técnica Delphi , Neoplasias Esofágicas/diagnóstico , Neoplasias Esofágicas/patología , Neoplasias Esofágicas/terapia , Esofagoscopía , Humanos
3.
Dig Endosc ; 35(5): 615-624, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36434769

RESUMEN

OBJECTIVES: To examine whether reasonable detection rate of endoscopically diagnosed lesions as adenoma ("endoscopic" adenoma detection rate [ADR]) could be calculated with a database generated from colonoscopy reports and whether it could be used as a surrogate colonoscopy quality indicator of "pathological" ADR. METHODS: A lesion-by-lesion database of colonoscopies performed between 2010 and 2020 at eight Japanese endoscopy centers and corresponding pathology database were integrated. Differences in numbers of detected polyps, "endoscopic" and "pathological" adenomas, and what these differences could be attributed to were examined. Polyp detection rate (PDR), "endoscopic" and "pathological" ADRs, and correlation coefficients between "pathological" ADR and PDR or "endoscopic" ADR by each endoscopist were calculated. RESULTS: Overall, 129,065 colonoscopy reports were analyzed. Among a total of 146,854 polyps, more "endoscopic" adenomas (n = 117,359) were observed than "pathological" adenomas (n = 70,076), primarily because adenomas were not resected on site, rather than because of a misdiagnosis. In all patients analyzed, PDR, "endoscopic" and "pathological" ADRs were 56.4% (95% confidence interval [CI] 56.2-56.7), 48.0% (95% CI 47.7-48.3), and 32.7% (95% CI 32.5-33.0), respectively. "Endoscopic" and "pathological" ADRs from each endoscopist showed a high correlation in hospitals where adenomas were usually resected at the time of examination. CONCLUSIONS: By appropriately describing endoscopically diagnosed lesions as "adenomas" in endoscopy reports, "endoscopic" ADR might be used as a surrogate colonoscopy quality indicator of "pathological" ADR (UMIN000040690).


Asunto(s)
Adenoma , Pólipos del Colon , Neoplasias Colorrectales , Pólipos , Humanos , Indicadores de Calidad de la Atención de Salud , Colonoscopía/efectos adversos , Adenoma/diagnóstico , Adenoma/etiología , Errores Diagnósticos , Detección Precoz del Cáncer , Pólipos del Colon/patología , Neoplasias Colorrectales/patología
4.
Dig Endosc ; 34(1): 144-152, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33774877

RESUMEN

OBJECTIVES: The Japan Endoscopy Database Project was initiated to develop the world's largest endoscopy data repository. This study describes the first phase of the colonoscopy project in Japan. METHODS: Data were aggregated offline by integrating information from the endoscopy database software from January 2015 through March 2017. The study population included all patients who underwent colonoscopy at eight centers. RESULTS: A total of 31,395 patients who underwent 38,497 colonoscopy procedures were registered. The majority of procedures were performed for screening (n = 14,156), followed by fecal immunochemical test positivity (n = 3960), abdominal symptoms (n = 3864), post-colorectal surgery surveillance (n = 3431), post-endoscopic treatment surveillance (n = 3757), thorough pre-treatment examination (n = 2822), and therapeutic purposes (n = 6507). In the screening group, advanced cancers, early cancers, and adenomas were diagnosed endoscopically in 2.1%, 1.3%, and 28.7% of cases, respectively, while in the fecal immunochemical test-positive group, they were diagnosed in 2.5%, 1.9%, and 41.6% of cases, respectively. The incidence of complications was 0.177% and 0.152% in the screening and fecal immunochemical test-positive groups, respectively. The therapeutic procedures included 1446 cold forceps polypectomy procedures, 4770 cold snare polypectomy procedures, 368 hot biopsies, 2998 hot snare polypectomy procedures, 9775 endoscopic or piecemeal endoscopic mucosal resections, and 1660 endoscopic submucosal dissections. A total of 173 procedure-related complications (0.82%) occurred in 21,017 therapeutic procedures performed in 15,744 patients. CONCLUSIONS: The first phase of the Japan Endoscopy Database Project established the proportions of the diagnostic and therapeutic colonoscopy procedures, and complication rates in real-world settings.


Asunto(s)
Adenoma , Pólipos del Colon , Neoplasias Colorrectales , Colonoscopía , Humanos , Japón/epidemiología , Sangre Oculta
5.
Digestion ; 102(6): 845-853, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33592610

RESUMEN

INTRODUCTION AND AIMS: This international survey was performed to evaluate the cumulative incidence of nosocomial novel coronavirus disease 2019 (COVID-19) among healthcare professionals during endoscopic procedures. METHODS: We performed an international web-based self-reported questionnaire survey. Participants completed the questionnaires every week for 12 weeks. The questionnaire elicited responses regarding the development of COVID-19 and details of the personal protective equipment (PPE) used. RESULTS: All 483 participants were included in the analysis. Participants had a mean age of 42.3 years and comprised 68.3% males. The geographic distribution of the study population was Asia (89.2%), Europe (2.9%), North and South America (4.8%), Oceania (0.6%), and Africa (1.5%). The most common endoscopy-related role of the participants was endoscopist (78.7%), and 74.5% had >10 years of experience. Fourteen participants had performed 83 endoscopic procedures in patients positive for COVID-19. During the mean follow-up period of 4.95 weeks, there were no cases of COVID-19 when treating COVID-19 positive patients. The most common PPE used by participants treating patients with COVID-19 was a surgical mask plus N95 mask plus face shield, goggles, cap, long-sleeved isolation gown, and single pair of gloves. The most common PPE used by participants treating patients without COVID-19 was a surgical mask, no face shield but goggles, cap, long-sleeved isolation gown, and single pair of gloves during all endoscopic procedures. CONCLUSIONS: The risk of COVID-19 transmission during any endoscopic procedure was low in clinical practice.


Asunto(s)
COVID-19 , Equipo de Protección Personal , Adulto , Endoscopía , Femenino , Humanos , Transmisión de Enfermedad Infecciosa de Paciente a Profesional , Masculino , SARS-CoV-2 , Encuestas y Cuestionarios
6.
Dig Endosc ; 32(2): 168-179, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31529547

RESUMEN

Although esophagogastroduodenoscopy (EGD) is the most commonly used procedure in the gastrointestinal (GI) tract, the method of esophageal, gastric and duodenal mucosa photodocumentation varies considerably worldwide. One probable explanation is that for generations, EGD has primarily been taught by GI faculty and instructors based on their perceptions and experience, which has resulted in EGD being a non-standardized procedure. Currently, the procedure is facing a challenging scenario as endoscopy societies are implementing procedure-associated quality indicators aiming for best practice among practitioners and evidence-based care for patients. Contrary to colonoscopy where cecum landmarks photodocumentation is considered proof of completeness, there are currently no reliable performance measures to gauge the completeness of an upper endoscopy nor guidance for complete photodocumentation. This World Endoscopy Organization (WEO) position statement aims to provide practical guidance to practitioners to carry out complete EGD photodocumentation. Hence, an international group of experts from the WEO Upper GI Cancer Committee formulated the following document using the body of evidence established through literature reviews, expert opinions, and other scientific sources. The group acknowledged that although the procedure should be feasible in any facility, what is needed to achieve a global shift on the concept of completeness is a common written statement of agreement on its potential impact and added value. This best practice statement offers endoscopists principles and practical guidance in order to carry out complete photodocumentation from the hypopharynx to the second duodenal portion.


Asunto(s)
Documentación/métodos , Endoscopía del Sistema Digestivo/normas , Fotograbar/estadística & datos numéricos , Guías de Práctica Clínica como Asunto , Tracto Gastrointestinal Superior/diagnóstico por imagen , Femenino , Humanos , Masculino , Organización Mundial de la Salud
7.
Dig Endosc ; 32(5): 648-650, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32335946

RESUMEN

All gastrointestinal endoscopic procedures have a high risk of aerosol contamination of the coronavirus disease 2019 (COVID-19) to endoscopists, nurses, and healthcare assistants. Given the current pandemic situation of COVID-19, the Japan Gastroenterological Endoscopy Society issued the recommendation for gastrointestinal (GI) endoscopy based on the status of COVID-19 as of April 9, 2020, in Japan: (i) indications for GI endoscopy in the pandemic of COVID-19; (ii) practical protective equipment for medical personnel depending on the risk for COVID-19; (iii) preprocedural management, such as pharyngeal local anesthesia using lidocaine spray which has a potential to generate the aerosols; (iv) ideal settings of the endoscopy room including the numbers of the staff and the patients; (v) postprocedural management, such as undressing and follow-up of the patients, as well as the involved staff, were documented to fit the practical scenarios in GI endoscopy, with the available data in Japan and the world. We believe that certain measures will prevent further spread of COVID-19.


Asunto(s)
Infecciones por Coronavirus/prevención & control , Endoscopía Gastrointestinal/normas , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , Pandemias/prevención & control , Equipo de Protección Personal/estadística & datos numéricos , Neumonía Viral/prevención & control , Guías de Práctica Clínica como Asunto , COVID-19 , Femenino , Humanos , Control de Infecciones/métodos , Japón , Masculino , Salud Laboral , Sociedades Médicas
8.
Dig Endosc ; 32(4): 494-502, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-31361923

RESUMEN

BACKGROUND AND AIM: Few studies have reported on a national, population-based endoscopic retrograde cholangiopancreatography (ERCP) database. Hence, in 2015, we established a multicenter ERCP database registry, the Japan Endoscopic Database (JED) Project in preparation for a nationwide endoscopic database. The objective the present study was to evaluate this registry before the establishment of a nationwide endoscopic database. METHODS: From 1 January 2015 to 31 March 2017, we collected and analyzed the ERCP data of all patients who underwent ERCP in four participating centers in the JED Project based on the JED protocol. RESULTS: Four centers carried out 4104 ERCP on 2173 patients. Data entry of ERCP information (age, 100%; gender, 100%; American Society of Anesthesiologists Physical Status Classification System, 74.5%; scope, 92.7%; time to ERCP, 100%; antithrombotic drug information, 55.0%; primary selective common bile duct [CBD] cannulation methods, 73.0%; number of attempts at primary selective CBD cannulation, 67.6%; overall selective CBD cannulation methods, 68.9%; ERCP procedure time, 66.3%; fluoroscopy time, 65.1%; adverse events, 74.9%; serum amylase levels 1 day post-ERCP, 36.5%) was accurately extracted from the four centers. Success rate of CBD cannulation by level of ERCP difficulty was 98.5%, 99.0%, and 96.4% in grades 1, 2, and 3, respectively. Complication rate by overall selective CBD cannulation method was 5.6%, 7.6%, and 10.5% in the contrast-assisted technique, guidewire-assisted technique, and cross-over method, respectively. CONCLUSION: Data from this evaluation of the JED Project, a multicenter ERCP database registry, suggest the feasibility of establishing a nationwide ERCP database and its challenges.


Asunto(s)
Enfermedades de los Conductos Biliares/cirugía , Colangiopancreatografia Retrógrada Endoscópica/estadística & datos numéricos , Bases de Datos Factuales , Enfermedades Pancreáticas/cirugía , Sistema de Registros , Adulto , Anciano , Anciano de 80 o más Años , Enfermedades de los Conductos Biliares/diagnóstico , Enfermedades de los Conductos Biliares/epidemiología , Femenino , Humanos , Japón/epidemiología , Masculino , Persona de Mediana Edad , Enfermedades Pancreáticas/diagnóstico , Enfermedades Pancreáticas/epidemiología
9.
Dig Endosc ; 32(5): 651-657, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32470171

RESUMEN

Some situations may require endoscopy during the COVID-19 (Coronavirus Disease 2019) pandemic. Here, we describe the necessary precautions in the form of clinical questions and answers (Q&A) regarding the safe deployment of gastrointestinal endoscopy in such situations while protecting endoscopy staff and patients from infection. Non-urgent endoscopy should be postponed. The risk of infection in patients should be evaluated in advance by questionnaire and body temperature. The health of staff must be checked every day. Decisions to employ endoscopy should be based on the institutional conditions and aims of endoscopy. All endoscopic staff need to wear appropriate personal protective equipment (PPE). The endoscope and other devices should be cleaned and disinfected after procedures in accordance with the relevant guidelines. Optimal management of the endoscopy unit is required. Endoscopy for infected patients or those with suspected infection demands exceptional caution. When a patient who undergoes endoscopy is later found to have COVID-19, the members of staff involved are considered exposed to the virus and must not work for at least 14 days if their PPE is considered insufficient. When PPE resources are limited, some equipment may be used continuously throughout a shift as long as it is not contaminated. Details of the aforementioned protective measures are described.


Asunto(s)
Infecciones por Coronavirus/prevención & control , Endoscopía Gastrointestinal/métodos , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , Pandemias/prevención & control , Equipo de Protección Personal/estadística & datos numéricos , Neumonía Viral/prevención & control , COVID-19 , Infecciones por Coronavirus/epidemiología , Endoscopía Gastrointestinal/efectos adversos , Femenino , Humanos , Control de Infecciones/métodos , Masculino , Salud Laboral , Pandemias/estadística & datos numéricos , Neumonía Viral/epidemiología , Administración de la Seguridad , Encuestas y Cuestionarios
10.
Digestion ; 100(2): 117-126, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30408803

RESUMEN

AIM: To clarify whether antithrombotic drugs affect diagnosis using the immunochemical faecal occult blood test -(iFOBT) of colorectal neoplasia. METHODS: Using the Japan Endoscopy Database from 8 centres between 2015 and 2017, we analyzed data about patients who were iFOBT positive and had received direct oral anticoagulants (DOAC), warfarin, aspirin or thienopyridine. One-to-one matching-analogue propensity score weighted analyses were performed to compare the positive predictive value (PPV) of all neoplasms, invasive and non-invasive colorectal cancers and adenomas between drug users and non-users. All neoplasms included invasive and non-invasive colorectal cancer, and adenomas. RESULTS: We analyzed 197 DOAC users and 196 non-users, 153 warfarin users and 153 non-users, 408 aspirin users and 415 non-users, and 97 thienopyridine users and 97 non-users. No significant differences were observed in the PPV for all neoplasms (56.67 vs. 50.43%), invasive cancer (4.32 vs. 3.53%), non-invasive cancer (15.58 vs. 15.56%) or adenoma (53.13 vs. 48.09%) between the DOAC user and non-user groups. No significant differences were observed in the PPV for all neoplasia, invasive and non-invasive cancer, or adenoma between warfarin, aspirin and thienopyridine use and non-users. CONCLUSIONS: DOAC, warfarin, aspirin and thienopyridine use did not decrease the PPVs of the iFOBT used to evaluate all colorectal neoplasia.


Asunto(s)
Adenoma/diagnóstico , Anticoagulantes/efectos adversos , Neoplasias Colorrectales/diagnóstico , Tamizaje Masivo/métodos , Administración Oral , Anciano , Anciano de 80 o más Años , Anticoagulantes/administración & dosificación , Aspirina/administración & dosificación , Aspirina/efectos adversos , Estudios de Casos y Controles , Colonoscopía , Reacciones Falso Positivas , Heces/química , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Sangre Oculta , Valor Predictivo de las Pruebas , Estudios Prospectivos , Piridinas/administración & dosificación , Piridinas/efectos adversos , Estudios Retrospectivos , Warfarina/administración & dosificación , Warfarina/efectos adversos
11.
Dig Endosc ; 31(5): 477-497, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31241788

RESUMEN

As part of the activities toward standardizing endoscopy procedures, the Japan Gastroenterological Endoscopy Society has prepared guidelines for cleansing and disinfection of gastrointestinal endoscopes. The environment of gastrointestinal endoscopy differs between Japan and advanced Western countries. In advanced Western countries, gastrointestinal endoscopy is performed almost exclusively at specialized facilities, where strict provisions are observed for cleansing and disinfecting endoscopes. In Japan, however, gastrointestinal endoscopy is performed even in small clinics, and the annual number of gastrointestinal endoscopy cases is enormous. In addition, the method for cleansing and disinfecting endoscopes differs among hospitals. Although there is a distinct lack of evidence for how gastrointestinal endoscopes are cleaned and disinfected, it is necessary to standardize the method for doing so to advance the field of endoscopic medicine.


Asunto(s)
Desinfección , Endoscopios Gastrointestinales , Contaminación de Equipos , Humanos , Desinfección/normas , Contaminación de Equipos/prevención & control , Japón
12.
Esophagus ; 16(2): 174-179, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30519821

RESUMEN

PURPOSE: The aim was to investigate the current status of esophageal endoscopy, including the evaluation of smoking and alcohol consumption, in Japan. METHODS: A total of 47,441 patients who underwent 69,748 sessions of esophageal endoscopy were registered in the Japan Endoscopy Database between January 2015 and March 2017. The study variables were as follows: (1) methods for monitoring the esophagus and the time required for monitoring and (2) the status of smoking and alcohol consumption in patients with esophageal cancer and head and neck cancer. RESULTS: Image-enhanced endoscopy was performed in 10.6%, Lugol chromoendoscopy in 4.1%, and magnifying endoscopy in 3.2%. The mean time required for gastrointestinal endoscopy was 10 min 58 s. The mean examination times in patients with or without monitoring of the head and neck were 10 min 51 s and 11 min 13 s, respectively. In 57.0% of the patients with esophageal cancer, the head and neck were monitored at the time of gastrointestinal endoscopy. The proportion of current smokers (esophageal cancer: 16.8-4.7%; head and neck cancer: 24.3-9.3%) and addicted drinkers (esophageal cancer: 52.3-40.8%; head and neck cancer: 50.2-47.3%) were lower at the second or subsequent endoscopy than at the initial endoscopy. CONCLUSIONS: The new strategy for esophageal endoscopy has led to an evolutionary change in Japan. The patients with esophageal cancer and head and neck cancer who underwent a second or subsequent endoscopy had lower incidences of smoking and alcohol consumption, although the incidences remained high.


Asunto(s)
Consumo de Bebidas Alcohólicas/epidemiología , Neoplasias Esofágicas/epidemiología , Esofagoscopía/estadística & datos numéricos , Fumar/epidemiología , Neoplasias de Cabeza y Cuello/epidemiología , Humanos , Incidencia , Examen Físico/estadística & datos numéricos , Factores de Tiempo
13.
Gut ; 67(7): 1209-1228, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29463614

RESUMEN

OBJECTIVES: Interventional endoscopic ultrasonography (EUS) procedures are gaining popularity and the most commonly performed procedures include EUS-guided drainage of pancreatic pseudocyst, EUS-guided biliary drainage, EUS-guided pancreatic duct drainage and EUS-guided celiac plexus ablation. The aim of this paper is to formulate a set of practice guidelines addressing various aspects of the above procedures. METHODS: Formulation of the guidelines was based on the best scientific evidence available. The RAND/UCLA appropriateness methodology (RAM) was used. Panellists recruited comprised experts in surgery, interventional EUS, interventional radiology and oncology from 11 countries. Between June 2014 and October 2016, the panellists met in meetings to discuss and vote on the clinical scenarios for each of the interventional EUS procedures in question. RESULTS: A total of 15 statements on EUS-guided drainage of pancreatic pseudocyst, 15 statements on EUS-guided biliary drainage, 12 statements on EUS-guided pancreatic duct drainage and 14 statements on EUS-guided celiac plexus ablation were formulated. The statements addressed the indications for the procedures, technical aspects, pre- and post-procedural management, management of complications, and competency and training in the procedures. All statements except one were found to be appropriate. Randomised studies to address clinical questions in a number of aspects of the procedures are urgently required. CONCLUSIONS: The current guidelines on interventional EUS procedures are the first published by an endoscopic society. These guidelines provide an in-depth review of the current evidence and standardise the management of the procedures.


Asunto(s)
Endosonografía , Enfermedades Pancreáticas/diagnóstico por imagen , Enfermedades Pancreáticas/cirugía , Ultrasonografía Intervencional , Asia , Plexo Celíaco , Competencia Clínica , Drenaje , Humanos , Bloqueo Nervioso , Enfermedades Pancreáticas/etiología , Selección de Paciente , Sociedades Médicas , Stents
14.
Dig Endosc ; 30(1): 5-19, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28905472

RESUMEN

The advent of electronic medical records brought image filing systems to many hospitals, as well as electronic endoscopic medical records. However, data integration among multiple different vendors has not yet been accomplished. We start the Japan Endoscopic Database (JED) Project endorsed by Japan Gastroenterological Endoscopy Society (JGES) from January 2015. The purposes of this project are as follows: (i) developing the world's largest endoscopic database generated from daily use of the reporting system; (ii) capturing the actual performance of endoscopic practice in Japan; and (iii) standardizing the terminology and fundamental items for registry of clinical studies. Moreover, the JED project has the potential to automatically collect data about adverse events, competency and evaluation of residents, and actual numbers of procedures on a nationwide scale, certification for the specialty board system, and so on. We believe that this design paper will be helpful not only for future nationwide research but also for international research (UMIN000016093).


Asunto(s)
Endoscopía Gastrointestinal/estadística & datos numéricos , Gastroenterología/estadística & datos numéricos , Sociedades Médicas , Bases de Datos Factuales , Humanos , Japón
15.
Dig Endosc ; 30(1): 20-28, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28885724

RESUMEN

BACKGROUND AND AIM: The Japan Endoscopy Database (JED) Project was started to develop the world's largest endoscopic database, capture the actual performance of endoscopic practice, and standardize the terminology and fundamental items needed for a clinical and research registry. This paper presents a progress report on the first phase of this project undertaken at eight endoscopic centers in Japan. METHODS: The list of data items to be collected was drafted by the MSED-J (Minimal Standard Endoscopic Database) subcommittee. These items were aggregated offline by integrating data from two endoscopic filing systems between July 2015 and December 2015. The study population included all patients who underwent esophagogastroduodenoscopy or colonoscopy at all eight centers, patients who underwent enteroscopy at five of the eight centers, and patients who underwent endoscopic retrograde cholangiopancreatography (ERCP) at four of the eight centers. RESULTS: Data collected in this phase included 61 070 endoscopic procedures, of which 40 475 were esophagogastroduodenoscopies, 215 were enteroscopies, 19 204 were colonoscopies, and 1176 were ERCPs. Frequencies of complications were 0.68% for esophagogastroduodenoscopy, 0% for enteroscopy, 0.43% for colonoscopy, and 13.34% for ERCP. In addition, we obtained various data including Helicobacter pylori infection status, past history of endoscopy in patients who underwent enteroscopy or colonoscopy, and degree of difficulty of ERCP, although the frequencies of reporting were sometimes low, with some items <20%. CONCLUSION: Results of the first phase suggest that the JED project can provide vast quantities of useful data about endoscopic procedures.


Asunto(s)
Enfermedades del Sistema Digestivo/diagnóstico , Endoscopía Gastrointestinal/estadística & datos numéricos , Informe de Investigación , Bases de Datos Factuales , Femenino , Humanos , Japón , Masculino , Estudios Prospectivos
16.
Dev Growth Differ ; 59(4): 228-243, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28470724

RESUMEN

The cerebellum is derived from the dorsal part of the anterior-most hindbrain. The vertebrate cerebellum contains glutamatergic granule cells (GCs) and gamma-aminobutyric acid (GABA)ergic Purkinje cells (PCs). These cerebellar neurons are generated from neuronal progenitors or neural stem cells by mechanisms that are conserved among vertebrates. However, vertebrate cerebella are widely diverse with respect to their gross morphology and neural circuits. The cerebellum of cyclostomes, the basal vertebrates, has a negligible structure. Cartilaginous fishes have a cerebellum containing GCs, PCs, and deep cerebellar nuclei (DCNs), which include projection neurons. Ray-finned fish lack DCNs but have projection neurons termed eurydendroid cells (ECs) in the vicinity of the PCs. Among ray-finned fishes, the cerebellum of teleost zebrafish has a simple lobular structure, whereas that of weakly electric mormyrid fish is large and foliated. Amniotes, which include mammals, independently evolved a large, foliated cerebellum, which contains massive numbers of GCs and has functional connections with the dorsal telencephalon (neocortex). Recent studies of cyclostomes and cartilaginous fish suggest that the genetic program for cerebellum development was already encoded in the genome of ancestral vertebrates. In this review, we discuss how alterations of the genetic and cellular programs generated diversity of the cerebellum during evolution.


Asunto(s)
Peces/embriología , Peces/metabolismo , Mamíferos/embriología , Mamíferos/metabolismo , Pez Cebra/embriología , Pez Cebra/metabolismo , Animales , Evolución Biológica , Cerebelo/embriología , Cerebelo/metabolismo , Neuronas/citología , Neuronas/metabolismo
17.
Gastrointest Endosc ; 86(2): 386-394, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28147226

RESUMEN

BACKGROUND AND AIMS: Most studies have not reported an improvement in the detection of adenomas with the use of image-enhanced colonoscopy methods, possibly because of the darkness of the images. To overcome this limitation, a new-generation endoscopic system has been developed. This system has 2 blue-laser imaging (BLI) observation modes. The BLI observation was set to BLI-bright mode to detect lesions. We aimed to evaluate the efficacy of BLI in detecting lesions. METHODS: This study was designed as a randomized controlled trial with participants from 8 institutions. We enrolled patients aged ≥40 years. The participants were randomly assigned to 2 groups: observation by using white-light imaging (WLI) with a conventional xenon light source (WLI group) or observation by using BLI-bright mode with a laser light source (BLI group). All of the detected lesions were resected or had a biopsy taken for histopathologic analysis. The primary outcome was the mean number of adenomas per patient (MAP) that were detected per procedure. RESULTS: The WLI and BLI groups consisted of 474 and 489 patients, respectively. The MAP was significantly higher in the BLI group than in the WLI group (mean ± standard deviation [SD] WLI 1.01 ± 1.36, BLI 1.27 ± 1.73; P = .008). Adenoma detection rate in the BLI group was not significantly higher than in the WLI group. Observation times differed significantly, with BLI (9.48 minutes) being longer than WLI (8.42; P < .001). The mean (± SD) number of polyps per patient was significantly higher in the BLI group compared with the WLI group (WLI 1.43 ± 1.64, BLI 1.84 ± 2.09; P = .001). CONCLUSIONS: A newly developed system that uses BLI improves the detection of adenomatous lesions compared with WLI. (Clinical trial registration number: UMIN 000014555.).


Asunto(s)
Adenoma/diagnóstico por imagen , Pólipos del Colon/diagnóstico por imagen , Colonoscopía/instrumentación , Neoplasias Colorrectales/diagnóstico por imagen , Rayos Láser , Adenoma/patología , Adenoma/cirugía , Anciano , Biopsia , Colonoscopía/métodos , Color , Neoplasias Colorrectales/patología , Neoplasias Colorrectales/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad
18.
Nippon Ganka Gakkai Zasshi ; 121(1): 17-22, 2017 Jan.
Artículo en Japonés | MEDLINE | ID: mdl-30079999

RESUMEN

Purpose: As the relationships between refraction and birth month suggest that day length factors affect the infantile refractive development, we aimed to prove the effect of day length factors by examining its evidence even among the elderly. Methods: We studied 1622 patients with cataracts (740 men and 882 women) who had preparatory measurements for corneal radius, axial lengths, and refractions for intraocular lens implantation. The day lengths for which each subject was exposed to from the first to eleventh month since birth were represented by variables DL1 to DL11. Similarly, absolute deviations from the yearly average of day lengths were represented by DDL1 to DDL11. We performed multiple regression analysis by substituting DL or DDL as explanatory variables for corneal radius, axial length, or refraction. Results: DLs were not relevant variables in elucidating corneal radius, axial length, and refraction. In contrast, DDLs were relevant variables in elucidating corneal radius (p<0.05). This association weakened for refraction and was not pertinent for axial length. Conclusion: Infantile refractive development is affected by the deviation in day length rather than the day length itself, evidence for which can still be observed among the elderly.


Asunto(s)
Catarata/fisiopatología , Ojo/crecimiento & desarrollo , Refracción Ocular , Errores de Refracción , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Lactante , Masculino , Persona de Mediana Edad , Análisis de Regresión , Estaciones del Año , Pruebas de Visión
19.
Dev Biol ; 397(1): 1-17, 2015 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-25300581

RESUMEN

The cerebellum is involved in some forms of motor coordination and motor learning. Here we isolated transgenic (Tg) zebrafish lines that express a modified version of Gal4-VP16 (GFF) in the cerebellar neural circuits: granule, Purkinje, or eurydendroid cells, Bergmann glia, or the neurons in the inferior olive nuclei (IO) which send climbing fibers to Purkinje cells, with the transposon Tol2 system. By combining GFF lines with Tg lines carrying a reporter gene located downstream of Gal4 binding sequences (upstream activating sequence: UAS), we investigated the anatomy and developmental processes of the cerebellar neural circuitry. Combining an IO-specific Gal4 line with a UAS reporter line expressing the photoconvertible fluorescent protein Kaede demonstrated the contralateral projections of climbing fibers. Combining a granule cell-specific Gal4 line with a UAS reporter line expressing wheat germ agglutinin (WGA) confirmed direct and/or indirect connections of granule cells with Purkinje cells, eurydendroid cells, and IO neurons in zebrafish. Time-lapse analysis of a granule cell-specific Gal4 line revealed initial random movements and ventral migration of granule cell nuclei. Transgenesis of a reporter gene with another transposon Tol1 system visualized neuronal structure at a single cell resolution. Our findings indicate the usefulness of these zebrafish Gal4 Tg lines for studying the development and function of cerebellar neural circuits.


Asunto(s)
Cerebelo/embriología , Proteínas de Unión al ADN/genética , Factores de Transcripción/genética , Proteínas de Pez Cebra/genética , Animales , Animales Modificados Genéticamente , Movimiento Celular , Cerebelo/fisiología , Elementos Transponibles de ADN , Elementos de Facilitación Genéticos , Regulación del Desarrollo de la Expresión Génica , Genes Reporteros , Técnicas Genéticas , Proteínas Fluorescentes Verdes/metabolismo , Vías Nerviosas , Neuronas/fisiología , Células de Purkinje/citología , Sinapsis , Transgenes , Pez Cebra/embriología , Pez Cebra/genética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA