Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Catheter Cardiovasc Interv ; 103(6): 833-842, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38639137

RESUMEN

BACKGROUND: Stent underexpansion, typically related to lesion calcification, is the strongest predictor of adverse events after percutaneous coronary intervention (PCI). Although uncommon, underexpansion may also occur in non-severely calcified lesions. AIM: We sought to identify the prevalence and anatomical characteristics of underexpansion in non-severely calcified lesions. METHODS: We included 993 patients who underwent optical coherence tomography-guided PCI of 1051 de novo lesions with maximum calcium arc <180°. Negative remodeling (NR) was the smallest lesion site external elastic lamina diameter that was also smaller than the distal reference. Stent expansion was evaluated using a linear regression model accounting for vessel tapering; underexpansion required both stent expansion <70% and stent area <4.5mm2. RESULTS: Underexpansion was observed in 3.6% of non-heavily calcified lesions (38/1051). Pre-stent maximum calcium arc and thickness were greater in lesions with versus without underexpansion (median 119° vs. 85°, p = 0.002; median 0.95 mm vs. 0.78 mm, p = 0.008). NR was also more common in lesions with underexpansion (44.7% vs. 24.5%, p = 0.007). In the multivariable logistic regression model, larger and thicker eccentric calcium, mid left anterior descending artery (LAD) location, and NR were associated with underexpansion in non-severely calcified lesions. The rate of underexpansion was especially high (30.7%) in lesions exhibiting all three morphologies. Two-year TLF tended to be higher in underexpanded versus non-underexpanded stents (9.7% vs. 3.7%, unadjusted hazard ratio [95% confidence interval] = 3.02 [0.92, 9.58], p = 0.06). CONCLUSION: Although underexpansion in the absence of severe calcium (<180°) is uncommon, mid-LAD lesions with NR and large and thick eccentric calcium were associated with underexpansion.


Asunto(s)
Enfermedad de la Arteria Coronaria , Vasos Coronarios , Intervención Coronaria Percutánea , Stents , Tomografía de Coherencia Óptica , Calcificación Vascular , Humanos , Masculino , Femenino , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/terapia , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/efectos adversos , Anciano , Persona de Mediana Edad , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Prevalencia , Factores de Riesgo , Vasos Coronarios/diagnóstico por imagen , Resultado del Tratamiento , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Diseño de Prótesis , Valor Predictivo de las Pruebas , Factores de Tiempo , Angiografía Coronaria , Remodelación Vascular
2.
Curr Cardiol Rep ; 26(7): 757-765, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38809401

RESUMEN

PURPOSE OF REVIEW: To provide a summary of prevalence, pathogenesis, and treatment of coronary calcified nodules (CNs). RECENT FINDINGS: CNs are most frequently detected at the sites of hinge motion of severely calcified lesions such as in the middle segment of right coronary artery and left main coronary bifurcation. On histopathology, CNs exhibit two distinctive morphologies: eruptive and non-eruptive. Eruptive CNs, which have a disrupted fibrous cap with adherent thrombi, are biologically active. Non-eruptive CNs, which have an intact fibrous cap without thrombi, are biologically inactive, representing either healed eruptive CNs or protrusion of calcium due to plaque progression. Recent studies using optical coherence tomography (OCT) have shown a difference in the mechanism of stent failure in the two subtypes, demonstrating early reappearance of eruptive CNs in the stent (at ~ 6 months) as a unique mechanism of stent failure that does not seem to be preventable by simply achieving adequate stent expansion. The cause of CN reappearance in stent is not known and could be due to acute or subacute intrusion or continued growth of the CN. Whether modification of CN is needed, the most effective calcium modification modality and effectiveness of stent implantation in eruptive CNs has not been elucidated. In this review, we discuss pathogenesis of CNs and how intravascular imaging can help diagnose and manage patients with CNs. We also discuss medical and transcatheter therapies beyond conventional stent implantation for effective treatment of eruptive CNs that warrant testing in prospective studies.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Stents , Tomografía de Coherencia Óptica , Calcificación Vascular , Humanos , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/terapia , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Placa Aterosclerótica/diagnóstico por imagen
3.
Circ Cardiovasc Interv ; 17(4): e013702, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38525609

RESUMEN

BACKGROUND: Intravascular imaging and intracoronary physiology may both be used to guide and optimize percutaneous coronary intervention; however, they are rarely used together. The virtual flow reserve (VFR) is an optical coherence tomography (OCT)-based model of fractional flow reserve (FFR) facilitating the assessment of the physiological significance of coronary lesions. We aimed to validate the VFR assessment of intermediate coronary artery stenoses. METHODS: FUSION (Validation of OCT-Based Functional Diagnosis of Coronary Stenosis) was a multicenter, prospective, observational study comparing OCT-derived VFR to invasive FFR. VFR was mathematically derived from a lumped parameter flow model based on 3-dimensional lumen morphology. Patients undergoing coronary angiography with intermediate angiographic stenosis (40%-90%) requiring physiological assessment were enrolled. Investigational sites were blinded to the VFR analysis, and all OCT and FFR data were reviewed by an independent core laboratory. The coprimary end points were the sensitivity and specificity of VFR against FFR as the reference standard, each of which was tested against prespecified performance goals. RESULTS: After core laboratory review, 266 vessels in 224 patients from 25 US centers were included in the analysis. The mean angiographic diameter stenosis was 65.5%±14.9%, and the mean FFR was 0.83±0.11. Overall accuracy, sensitivity, and specificity of VFR versus FFR using a binary cutoff point of 0.80 were 82.0%, 80.4%, and 82.9%, respectively. The 97.5% lower confidence bound met the prespecified performance goal for sensitivity (71.6% versus 70%; P=0.01) and specificity (76.6% versus 75%; P=0.01). The area under the curve was 0.88 (95% CI, 0.84-0.92; P<0.0001). CONCLUSIONS: OCT-derived VFR demonstrates high sensitivity and specificity for predicting invasive FFR. Integrating high-resolution intravascular imaging with imaging-derived physiology may provide synergistic benefits as an adjunct to percutaneous coronary intervention. REGISTRATION: URL: https://clinicaltrials.gov; Unique identifier: NCT04356027.


Asunto(s)
Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Humanos , Constricción Patológica , Reserva del Flujo Fraccional Miocárdico/fisiología , Tomografía de Coherencia Óptica/métodos , Estudios Prospectivos , Resultado del Tratamiento , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/terapia , Angiografía Coronaria/métodos , Vasos Coronarios , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad
4.
Artículo en Inglés | MEDLINE | ID: mdl-38700097

RESUMEN

AIMS: Coronary computed tomography angiography provides noninvasive assessment of coronary stenosis severity and flow impairment. Automated artificial intelligence analysis may assist in precise quantification and characterization of coronary atherosclerosis, enabling patient-specific risk determination and management strategies. This multicenter international study compared an automated deep-learning-based method for segmenting coronary atherosclerosis in coronary computed tomography angiography (CCTA) against the reference standard of intravascular ultrasound (IVUS). METHODS AND RESULTS: The study included clinically stable patients with known coronary artery disease from 15 centers in the U.S. and Japan. An artificial intelligence (AI)-enabled plaque analysis service was utilized to quantify and characterize total plaque (TPV), vessel, lumen, calcified plaque (CP), non-calcified plaque (NCP), and low attenuation plaque (LAP) volumes derived from CCTA and compared with IVUS measurements in a blinded, core laboratory-adjudicated fashion. In 237 patients, 432 lesions were assessed; mean lesion length was 24.5 mm. Mean IVUS-TPV was 186.0 mm3. AI-enabled plaque analysis on CCTA showed strong correlation and high accuracy when compared with IVUS; correlation coefficient, slope, and Y intercept for TPV were 0.91, 0.99, and 1.87, respectively; for CP volume 0.91, 1.05, and 5.32, respectively; and for NCP volume 0.87, 0.98, and 15.24, respectively. Bland-Altman analysis demonstrated strong agreement with little bias for these measurements. CONCLUSIONS: Artificial intelligence enabled CCTA quantification and characterization of atherosclerosis demonstrated strong agreement with IVUS reference standard measurements. This tool may prove effective for accurate evaluation of coronary atherosclerotic burden and cardiovascular risk assessment.[ClinicalTrails.gov identifier: NCT05138289].

5.
J Am Coll Cardiol ; 84(4): 368-378, 2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-38759907

RESUMEN

BACKGROUND: ILUMIEN IV was the first large-scale, multicenter, randomized trial comparing optical coherence tomography (OCT)-guided vs angiography-guided stent implantation in patients with high-risk clinical characteristics and/or complex angiographic lesions. OBJECTIVES: The authors aimed to specifically examine outcomes in the complex angiographic lesions subgroup. METHODS: From the original trial population (N = 2,487), high-risk patients without complex angiographic lesions were excluded (n = 514). Complex angiographic lesion characteristics included: 1) long or multiple lesions with intended total stent length ≥28 mm; 2) bifurcation lesion with intended 2-stent strategy; 3) severely calcified lesion; 4) chronic total occlusion; or 5) in-stent restenosis. The study endpoints were: 1) final minimal stent area (MSA); 2) 2-year composite of serious major adverse cardiovascular events (MACEs) (cardiac death, target-vessel myocardial infarction [MI], or stent thrombosis); and 3) 2-year effectiveness, defined as target-vessel failure (TVF), a composite of cardiac death, target-vessel MI, or ischemia-driven target-vessel revascularization. RESULTS: The postpercutaneous coronary intervention (PCI) MSA was larger in the OCT-guided (n = 992) vs angiography-guided (n = 981) group (5.56 ± 1.95 mm2 vs 5.26 ± 1.81 mm2; difference, 0.30; 95% CI: 0.14-0.47; P < 0.001). Compared with angiography-guided PCI, OCT-guided PCI resulted in a lower risk of serious MACE (3.1% vs 4.9%; HR: 0.63; 95% CI: 0.40-0.99; P = 0.04). TVF was not significantly different between groups (7.3% vs 8.8%; HR: 0.82; 95% CI: 0.59-1.12; P = 0.20). CONCLUSIONS: In complex angiographic lesions, OCT-guided PCI led to a larger MSA and reduced the serious MACE, the composite of cardiac death, target-vessel MI, or stent thrombosis, compared with angiography-guided PCI at 2 years, but did not significantly improve TVF. (Optical Coherence Tomography Guided Coronary Stent Implantation Compared to Angiography: A Multicenter Randomized Trial in PCI; NCT03507777).


Asunto(s)
Angiografía Coronaria , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Masculino , Femenino , Angiografía Coronaria/métodos , Anciano , Persona de Mediana Edad , Intervención Coronaria Percutánea/métodos , Stents , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Resultado del Tratamiento
6.
EuroIntervention ; 20(3): e207-e215, 2024 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-38343369

RESUMEN

BACKGROUND: Outcomes after percutaneous coronary intervention (PCI) for de novo ostial right coronary artery (RCA) lesions are poor. AIMS: We used intravascular ultrasound (IVUS) to clarify the morphological patterns of de novo ostial RCA lesions and their associated clinical outcome. METHODS: Among 5,102 RCA IVUS studies, 170 de novo ostial RCA stenoses (within 3 mm from the aorto-ostium) were identified. These were classified as 1) isolated ostial lesions (no disease extending beyond 10 mm from the ostium and without a calcified nodule [CN]); 2) ostial CN, typically with diffuse disease (disease extending beyond 10 mm); and 3) ostial lesions with diffuse disease but without a CN. The primary outcome was target lesion failure (TLF: cardiac death, target vessel myocardial infarction, definite stent thrombosis, and ischaemia-driven target lesion revascularisation). RESULTS: The prevalence of an isolated ostial lesion was 11.8% (n=20), 47.6% (n=81) were ostial CN, and 40.6% (n=69) were ostial lesions with diffuse disease. Compared to ostial lesions with diffuse disease, isolated lesions were more common in women (75.0% vs 42.0%; p=0.01), and CN were associated with older age (median [first, third quartile] 76 [70, 83] vs 69 [63, 81] years old; p=0.002). The Kaplan-Meier rate of TLF at 2 years was significantly higher in patients with CN (21.6%) compared to diffuse lesions (8.2%) (p=0.04), and patients with isolated lesions had no events. A multivariable Cox proportional hazard model revealed that CN were significantly associated with TLF (hazard ratio 6.63, 95% confidence interval: 1.28-34.3; p=0.02). CONCLUSIONS: Ostial RCA lesions have specific morphologies - detectable by IVUS - that may be associated with long-term clinical outcomes.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Femenino , Anciano de 80 o más Años , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Intervención Coronaria Percutánea/efectos adversos , Resultado del Tratamiento , Factores de Riesgo , Angiografía Coronaria
7.
JACC Cardiovasc Interv ; 17(4): 491-501, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38340105

RESUMEN

BACKGROUND: Intravascular ultrasound (IVUS) studies show that one-quarter of left anterior descending (LAD) arteries have a myocardial bridge. An MB may be associated with stent failure when the stent extends into the MB. OBJECTIVES: The aim of this study was to investigate: 1) the association between an MB and chronic total occlusion (CTO) in any LAD lesions; and 2) the association between an MB and subsequent clinical outcomes after percutaneous coronary intervention in LAD CTOs. METHODS: A total of 3,342 LAD lesions with IVUS-guided percutaneous coronary intervention (280 CTO and 3,062 non-CTO lesions) were included. The primary outcome was target lesion failure (cardiac death, target vessel myocardial infarction, definite stent thrombosis, and ischemic-driven target lesion revascularization). RESULTS: An MB by IVUS was significantly more prevalent in LAD CTOs than LAD non-CTOs (40.4% [113/280] vs 25.8% [789/3,062]; P < 0.0001). The discrepancy in CTO length between angiography and IVUS was greater in 113 LAD CTOs with an MB than 167 LAD CTOs without an MB (6.0 [Q1, Q3: 0.1, 12.2] mm vs 0.2 [Q1, Q3: -1.4, 8.4] mm; P < 0.0001). Overall, 48.7% (55/113) of LAD CTOs had a stent that extended into an MB after which target lesion failure was significantly higher compared to a stent that did not extend into an MB (26.3% vs 0%; P = 0.0004) or compared to an LAD CTO without an MB (26.3% vs 9.6%; P = 0.02). CONCLUSIONS: An MB was more common in LAD CTO than non-CTO LAD lesions. If present, approximately one-half of LAD CTOs had a stent extending into an MB that, in turn, was associated with worse outcomes.


Asunto(s)
Oclusión Coronaria , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/terapia , Resultado del Tratamiento , Intervención Coronaria Percutánea/efectos adversos , Angiografía Coronaria , Enfermedad Crónica
8.
JACC Adv ; 2(7): 100564, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38939499

RESUMEN

Background: Accurate intravascular ultrasound (IVUS) measurements are important in IVUS-guided percutaneous coronary intervention optimization by choosing the appropriate device size and confirming stent expansion. Objectives: The purpose of this study was to assess the accuracy of machine learning (ML) automatic segmentation of coronary artery vessel and lumen dimensions and balloon sizing. Methods: Using expert analysis as the gold standard, ML segmentation of 60 MHz IVUS images was developed using 8,076 IVUS cross-sectional images from 234 patients, which were randomly split into training (83%) and validation (17%) data sets. The performance of ML segmentation was then evaluated using an independent test data set (437 images from 92 patients). The endpoints were the agreement rate between ML vs experts' measurements for appropriate balloon size selection, and lumen and acute stent areas. Appropriate balloon size was determined by rounding down from the mean vessel diameter or rounding up from the mean lumen diameter to the next balloon size. The difference of lumen area ≥0.5 mm2 was considered as clinically significant. Results: ML model segmentation correlated well with experts' segmentation for training data set with a correlation coefficient of 0.992 and 0.993 for lumen and vessel areas, respectively. The agreement rate in lumen and acute stent areas was 85.5% and 97.0%, respectively. The agreement rate for appropriate balloon size selection was 70.6% by vessel diameter only and 92.4% by adding lumen diameter. Conclusions: ML model IVUS segmentation measurements were well-correlated with those of experts and selected an appropriate balloon size in more than 90% of images.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA