Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Transfusion ; 58(8): 2068-2081, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29770455

RESUMEN

The current reference method in the United States for measuring in vivo population red blood cell (RBC) kinetics utilizes chromium-51 (51 Cr) RBC labeling for determining RBC volume, 24-hour posttransfusion RBC recovery, and long-term RBC survival. Here we provide evidence supporting adoption of a method for kinetics that uses the biotin-labeled RBCs (BioRBCs) as a superior, versatile method for both regulatory and investigational purposes. RBC kinetic analysis using BioRBCs has important methodologic, analytical, and safety advantages over 51 Cr-labeled RBCs. We critically review recent advances in labeling human RBCs at multiple and progressively lower biotin label densities for concurrent, accurate, and sensitive determination of both autologous and allogeneic RBC population kinetics. BioRBC methods valid for RBC kinetic studies, including successful variations used by the authors, are presented along with pharmacokinetic modeling approaches for the accurate determination of RBC pharmacokinetic variables in health and disease. The advantages and limitations of the BioRBC method-including its capability of determining multiple BioRBC densities simultaneously in the same individual throughout the entire RBC life span-are presented and compared with the 51 Cr method. Finally, potential applications and limitations of kinetic BioRBC determinations are discussed.


Asunto(s)
Biotinilación/métodos , Eritrocitos/metabolismo , Cinética , Práctica Clínica Basada en la Evidencia , Humanos
2.
J Pediatr ; 167(5): 1001-6, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26363547

RESUMEN

OBJECTIVE: Based on the hypothesis that neonatal autologous red blood cell (RBC) survival (RCS) is substantially shorter than adult RBC, we concurrently tracked the survival of transfused biotin-labeled autologous neonatal and allogeneic adult RBC into ventilated, very low birth weight infants. STUDY DESIGN: RBC aliquots from the first clinically ordered, allogeneic adult RBC transfusion and from autologous infant blood were labeled at separate biotin densities (biotin-labeled RBC [BioRBC]) and transfused. Survival of these BioRBCs populations were concurrently followed over weeks by flow cytometric enumeration using leftover blood. Relative tracking of infant autologous and adult allogeneic BioRBC was analyzed by linear mixed modeling of batched weekly data. When possible, Kidd antigen (Jka and Jkb) mismatches between infant and donor RBCs were also used to track these 2 populations. RESULTS: Contrary to our hypothesis, concurrent tracking curves of RCS of neonatal and adult BioRBC in 15 study infants did not differ until week 7, after which neonatal RCS became shortened to 59%-79% of adult enumeration values for uncertain reasons. Analysis of mismatched Kidd antigen RBC showed similar results, thus, confirming that BioRBC tracking is not perturbed by biotin RBC labeling. CONCLUSIONS: This study illustrates the utility of multidensity BioRBC labeling for concurrent measurement of RCS of multiple RBC populations in vivo. The similar RCS results observed for neonatal and adult BioRBCs transfused into very low birth weight infants provides strong evidence that the circulatory environment of the newborn infant, not intrinsic infant-adult RBC differences, is the primary determinant of erythrocyte survival. TRIAL REGISTRATION: Clinicaltrials.gov: NCT00731588.


Asunto(s)
Biotina/química , Transfusión de Eritrocitos/métodos , Adulto , Biotinilación , Supervivencia Celular , Eritropoyesis , Femenino , Citometría de Flujo , Humanos , Recién Nacido , Recien Nacido Prematuro , Recién Nacido de muy Bajo Peso , Sistema del Grupo Sanguíneo de Kidd , Masculino , Modelos Teóricos , Estudios Prospectivos , Trasplante Autólogo , Trasplante Homólogo
3.
Pediatr Res ; 74(6): 689-97, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24108188

RESUMEN

BACKGROUND: Anemia, a common condition among critically ill premature infants, is affected by red blood cell (RBC) survival (RCS). We hypothesized that transfused allogeneic Kidd antigen-mismatched RBCs would demonstrate the same concurrent RCS tracking as RBCs multilabeled at separate, discrete low densities with biotin (BioRBCs). METHODS: Allogeneic RBCs from adult donors were labeled at four biotin densities, mixed, and transfused into 17 anemic premature infants. Nine of the donors and neonates were Kidd antigen mismatched. Serial posttransfusion blood samples were assayed for up to 8 wk by flow cytometry to track the survival of the proportions of Kidd antigen-mismatched and Kidd antigen-biotinylated RBCs. RESULTS: Using linear mixed modeling to compare results, RCS of the three lowest BioRBC densities was similar to RCS by Kidd antigen mismatch and to one another. RCS of RBCs labeled at the highest BioRBC density was shortened. CONCLUSION: RCS of different populations of RBCs can be tracked concurrently and reliably using the three lowest BioRBC densities. Although comparable RCS results can be achieved using Kidd antigen mismatches, BioRBCs are preferred for investigating neonatal anemia because biotin labeling of both allogeneic and autologous RBCs is possible.


Asunto(s)
Biotina/metabolismo , Supervivencia Celular , Transfusión de Eritrocitos , Eritrocitos , Recien Nacido Prematuro , Sistema del Grupo Sanguíneo de Kidd/inmunología , Adulto , Eritrocitos/inmunología , Eritrocitos/metabolismo , Hemoglobina Fetal/metabolismo , Citometría de Flujo , Humanos , Recién Nacido
4.
Pediatr Res ; 74(5): 592-600, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24088873

RESUMEN

BACKGROUND: Study of the pathophysiology and treatment of anemia of prematurity is facilitated by direct measurement of red cell volume (RCV) utilizing microliter quantities of blood samples. Our objective was to compare concurrent measurements of multiple direct RCV methods in infants. METHODS: Eighteen preterm infants receiving clinically indicated transfusions had concurrent flow cytometric determinations of RCV and 24-h red blood cell (RBC) recovery based on donor-recipient differences of biotin-labeled RBCs (BioRBCs), Kidd antigen mismatched RBCs, and fetal hemoglobin-positive (HbF(+)) RBCs. High-performance liquid chromatography (HPLC) was also used for measuring HbF and adult hemoglobin protein concentrations for the determination of RCV. RESULTS: Concurrent RCV measurements using BioRBCs (18 and 54 µg/ml), Kidd antigen, and HbF flow cytometry were not statistically different compared with RCVs measured using the reference BioRBC density (6 µg/ml). By contrast, the HbF-HPLC method overestimated RCV by 45% compared with the reference method. All the methods demonstrated 100% 24-h posttransfusion RBC recovery (PTR24). CONCLUSION: Because BioRBC, Kidd antigen, and fetal hemoglobin (HbF) flow cytometry are safe and accurate methods requiring <10 µl of patient blood for determining RCV and PTR24 in preterm infants, they can be useful in clinical and research studies of anemia and other conditions.


Asunto(s)
Anemia/terapia , Volumen de Eritrocitos , Citometría de Flujo/métodos , Recien Nacido Prematuro/sangre , Recién Nacido de muy Bajo Peso/sangre , Transfusión Sanguínea/métodos , Cromatografía Líquida de Alta Presión/métodos , Hemoglobina Fetal/metabolismo , Humanos , Recién Nacido , Sistema del Grupo Sanguíneo de Kidd/análisis , Análisis de Regresión
5.
J Nutr ; 142(1): 22-6, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22157538

RESUMEN

To date, marginal, asymptomatic biotin deficiency has been successfully induced experimentally by the use of labor-intensive inpatient designs requiring rigorous dietary control. We sought to determine if marginal biotin deficiency could be induced in humans in a less expensive outpatient design incorporating a self-selected, mixed general diet. We sought to examine the efficacy of three outpatient study designs: two based on oral avidin dosing and one based on a diet high in undenatured egg white for a period of 28 d. In study design 1, participants (n = 4; 3 women) received avidin in capsules with a biotin binding capacity of 7 times the estimated dietary biotin intake of a typical self-selected diet. In study design 2, participants (n = 2; 2 women) received double the amount of avidin capsules (14 times the estimated dietary biotin intake). In study design 3, participants (n = 5; 3 women) consumed egg-white beverages containing avidin with a biotin binding capacity of 7 times the estimated dietary biotin intake. Established indices of biotin status [lymphocyte propionyl-CoA carboxylase activity; urinary excretion of 3-hydroxyisovaleric acid, 3-hydroxyisovaleryl carnitine (3HIA-carnitine), and biotin; and plasma concentration of 3HIA-carnitine] indicated that study designs 1 and 2 were not effective in inducing marginal biotin deficiency, but study design 3 was as effective as previous inpatient study designs that induced deficiency by egg-white beverage. Marginal biotin deficiency can be induced experimentally by using a cost-effective outpatient design by avidin delivery in egg-white beverages. This design should be useful to the broader nutritional research community.


Asunto(s)
Biotina/deficiencia , Análisis Costo-Beneficio , Pacientes Ambulatorios , Animales , Enfermedades Carenciales/etiología , Enfermedades Carenciales/orina , Femenino , Humanos , Masculino , Ratones
6.
Transfusion ; 52(5): 1097-105, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22023312

RESUMEN

BACKGROUND: Safe, accurate methods to reliably measure circulating red blood cell (RBC) kinetics are critical tools to investigate pathophysiology and therapy of anemia, including hemolytic anemias. This study documents the ability of a method using biotin-labeled RBCs (BioRBCs) to measure RBC survival (RCS) shortened by coating with a highly purified monomeric immunoglobulin G antibody to D antigen. STUDY DESIGN AND METHODS: Autologous RBCs from 10 healthy D+ subjects were labeled with either biotin or (51) Cr (reference method), coated (opsonized) either lightly (n = 4) or heavily (n = 6) with anti-D, and transfused. RCS was determined for BioRBCs and for (51) Cr independently as assessed by three variables: 1) posttransfusion recovery at 24 hours (PTR(24) ) for short-term RCS; 2) time to 50% decrease of the label (T(50) ), and 3) mean potential life span (MPL) for long-term RCS. RESULTS: BioRBCs tracked both normal and shortened RCS accurately relative to (51) Cr. For lightly coated RBCs, mean PTR(24) , T(50) , and MPL results were not different between BioRBCs and (51) Cr. For heavily coated RBCs, both short-term and long-term RCS were shortened by approximately 17 and 50%, respectively. Mean PTR(24) by BioRBCs (84 ± 18%) was not different from (51) Cr (81 ± 10%); mean T(50) by BioRBCs (23 ± 17 days) was not different from (51) Cr (22 ± 18 days). CONCLUSION: RCS shortened by coating with anti-D can be accurately measured by BioRBCs. We speculate that BioRBCs will be useful for studying RCS in conditions involving accelerated removal of RBCs including allo- and autoimmune hemolytic anemias.


Asunto(s)
Biotina , Eritrocitos/fisiología , Isoanticuerpos/inmunología , Supervivencia Celular , Radioisótopos de Cromo , Humanos , Globulina Inmune rho(D)
7.
Transfusion ; 52(5): 963-73, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22229348

RESUMEN

BACKGROUND: Measurement of red blood cell (RBC) survival (RCS) is important for investigating pathophysiology and treatment of anemia. Our objective was to validate the multidensity biotin method for RCS determination in sheep, a commonly used model of RBC physiology. [(14) C]Cyanate served as the reference method for long-term RCS because the (51) Cr method (the reference method for humans) is not reliable in sheep. STUDY DESIGN AND METHODS: Aliquots of autologous RBCs from eight adult sheep were labeled with [(14) C]cyanate and four separate densities of biotin (BioRBCs) and reinfused. Short-term RCS was assessed by posttransfusion recovery at 24 hours (PTR(24) ); long-term RCS was assessed by the time to 50% survival (T(50) ) and mean potential life span (MPL). RESULTS: Values for PTR(24) of the four BioRBC densities were not different. Values for RCS as reflected by T(50) and MPL were nearly identical for [(14) C]cyanate and the two intermediate-density BioRBC populations. In contrast, the lowest-density BioRBC population survived slightly longer (p < 0.01), but with a difference of no clinical significance. The highest-density BioRBC population importantly shortened RCS (p < 0.01 compared to the two intermediate densities). CONCLUSION: This study provides evidence that BioRBCs labeled at four biotin densities can be used to independently and simultaneously measure short-term RCS and that BioRBCs labeled at the three lowest biotin densities can be used to accurately and simultaneously measure long-term RCS. Because the sheep RBC model is comparable to humans, this nonradioactive method has promise for use in RBC kinetic studies in neonates and pregnant women.


Asunto(s)
Biotina/metabolismo , Radioisótopos de Carbono , Cianatos/metabolismo , Eritrocitos/fisiología , Animales , Formación de Anticuerpos , Supervivencia Celular , Radioisótopos de Cromo , Humanos , Ovinos
8.
J Nutr ; 141(3): 353-8, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21248194

RESUMEN

Mounting evidence indicates that marginal biotin deficiency is not rare, contrary to previous assumptions. Accordingly, robust indicators of biotin status would be useful. In a study of 10 healthy adults, we recently provided evidence that abnormally increased plasma concentration of 3-hydroxyisovaleryl carnitine (3HIA-carnitine) is a sensitive indicator of marginal biotin deficiency. We sought to determine whether urinary excretion of 3HIA-carnitine (expressed as the ratio to urinary creatinine) significantly increases in marginal biotin deficiency. Marginal, asymptomatic biotin deficiency was induced experimentally in the same 10 healthy adults (8 women) by feeding undenatured egg white with meals for 28 d. Biotin status was repleted by a mixed general diet plus biotin supplementation. Urinary excretion of 3HIA-carnitine was determined by liquid chromatography-tandem MS on d 0, 14, and 28 (depletion) and on d 35 and 50 (repletion). Mean urinary 3HIA-carnitine concentration increased with depletion (P < 0.0001; d 0 vs. 28) and decreased with repletion (P = 0.0002; d 28 vs. 50). Urinary 3HIA-carnitine excretion was greater than the upper limit of normal in 9 of 10 participants by d 14 and decreased to within normal limits by d 50 in all participants. This study provides evidence that urinary excretion of 3HIA-carnitine is an early and sensitive indicator of marginal biotin deficiency. The ease of collection of untimed urine samples and application of a new analytical method with simplified sample preparation suggest that urinary 3HIA-carnitine is likely to be a useful indicator for large population studies.


Asunto(s)
Biotina/deficiencia , Carnitina/análogos & derivados , Estado Nutricional , Deficiencia de Vitamina B/diagnóstico , Deficiencia de Vitamina B/orina , Adulto , Biomarcadores/sangre , Biomarcadores/orina , Biotina/uso terapéutico , Carnitina/orina , Clara de Huevo , Femenino , Humanos , Linfocitos/enzimología , Masculino , Metilmalonil-CoA Descarboxilasa/sangre , Valores de Referencia , Factores de Tiempo , Deficiencia de Vitamina B/sangre , Deficiencia de Vitamina B/tratamiento farmacológico
9.
J Nutr ; 141(11): 1925-30, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21918059

RESUMEN

Experimentally increasing metabolic flux in a pathway in which an essential step is catalyzed by a vitamin-dependent enzyme (a challenge test) has been used in assessing functional vitamin status and elucidating common and alternate metabolic pathways. Conversion of 3-methylcrotonyl CoA to 3-methylglutaconyl CoA in the leucine catabolic pathway is catalyzed by the biotin-dependent enzyme methylcrotonyl-CoA carboxylase (MCC). Marginal biotin deficiency reduces MCC activity and increases urinary excretion of 3-hydroxyisovaleric acid (3HIA) and 3-hydroxyisovaleryl carnitine (3HIA-carnitine) measured in 24-h urine collections. We assessed urinary excretion of 3HIA and 3HIA-carnitine in response to a leucine challenge in humans made progressively biotin deficient by egg white consumption. In 2 cohorts of healthy adults (Study 1: n = 5; Study 2: n = 7) rendered biotin deficient over 28 d, urinary excretion of 3HIA and 3HIA-carnitine in response to a leucine challenge was quantitated weekly for 3 or 4 wk, respectively. In both studies, mean urinary excretion of both 3HIA and 3HIA-carnitine increased >2-fold by d 14 (P < 0.002 for both indicators for both studies). Diagnostically, both indicators were highly sensitive, but diagnostic sensitivities were not superior to those of 24-h excretion of 3HIA and 3HIA-carnitine. These studies provide evidence that urinary excretions of 3HIA and 3HIA-carnitine in response to an oral leucine challenge are early and sensitive indicators of marginal biotin deficiency in humans. The variability of the proportion of leucine catabolites excreted as 3HIA suggests substantial population heterogeneity in the metabolic capacity of the 3HIA-carnitine detoxification pathway.


Asunto(s)
Biotina/deficiencia , Carnitina/análogos & derivados , Leucina/administración & dosificación , Valeratos/orina , Adulto , Carnitina/orina , Estudios de Cohortes , Femenino , Humanos , Masculino
10.
Transfusion ; 51(5): 1047-57, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21062290

RESUMEN

BACKGROUND: Safe, accurate methods permitting simultaneous and/or repeated measurement of red blood cell (RBC) survival (RCS) are important to investigate pathophysiology and therapy of anemia. Methods using chromium 51 ((51) Cr)-labeled RBCs are unacceptable for infants, children, and pregnant women. We report RCS measured in vivo using RBCs labeled with several densities of biotin (BioRBCs). STUDY DESIGN AND METHODS: Aliquots of autologous RBCs from eight healthy adult subjects were labeled separately at four discrete biotin densities, mixed, and infused. The proportion of each population of BioRBCs circulating was determined serially by flow cytometry over 20 weeks. For each population, RCS was assessed by the following: 1) posttransfusion BioRBC recovery at 24 hours (PTR(24) ); 2) time to decrease to 50% of the enrichment at 24 hours (T(50) ); and 3) mean potential lifespan (MPL). RESULTS: Among the four BioRBC densities, no significant differences in PTR(24) were observed. T(50) and MPL were similar for the two lowest BioRBC densities. In contrast, the two highest BioRBC densities demonstrated progressively decreased T(50) and MPL. CONCLUSIONS: RBCs labeled at four biotin densities can be used to independently and accurately measure PTR(24 ) and two lowest biotin densities can accurately quantitate long-term RCS. This method provides a tool for investigating anemia in infants, fetuses, and pregnant women with the following advantages over the standard (51) Cr method: 1) study subjects are not exposed to radiation; 2) small blood volumes (e.g., 20 µL) are required; and 3) multiple independent RCS measurements can be made simultaneously in the same individual.


Asunto(s)
Biotina/metabolismo , Biotinilación/métodos , Transfusión de Eritrocitos/normas , Eritrocitos/citología , Citometría de Flujo/métodos , Adulto , Anticuerpos/sangre , Biotina/inmunología , Supervivencia Celular/fisiología , Eritrocitos/inmunología , Eritrocitos/metabolismo , Femenino , Citometría de Flujo/normas , Haptoglobinas/metabolismo , Hemólisis , Humanos , Masculino , Persona de Mediana Edad , Estándares de Referencia , Coloración y Etiquetado/métodos , Adulto Joven
11.
Transfusion ; 51(1): 148-57, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20630041

RESUMEN

BACKGROUND: Anemia is a serious problem in critically ill neonates. To investigate the pathophysiology of anemia and responses to red blood cell (RBC) transfusions and erythropoietin therapy, repeated measurement of red blood cell volume (RCV) and blood volume is useful. To extend our previous sheep study in which RBCs were labeled at four different biotin densities, we assessed the validity of this multidensity method for in vivo measurement of circulating RCV in humans. STUDY DESIGN AND METHODS: In eight healthy adults, autologous RBCs were biotinylated at each of four biotin densities (6, 18, 54, and 162 µg biotinylation reagent/mL RBC), mixed, and infused intravenously; blood was sampled at 10, 20, and 60 minutes. At each time, RCV was calculated from dilution of individual RBC populations enumerated by flow cytometry. RCV measurements from the population of RBCs biotinylated at 6 µg/mL were chosen as the reference values because this density had been previously validated against the 51Cr method in vitro and in vivo in humans. RESULTS: Values for RCVs were not significantly different among the four densities of biotinylated RBCs at any of the three time points and did not change over 60 minutes. CONCLUSIONS: These studies provide evidence that four densities of biotinylated RBCs can be used in vivo for simultaneous, independent, accurate measurements of RCV in humans. We speculate that this method will also be useful for repeated measurement of RCV and blood volume in infants and other patient populations in whom radioactive labels should be avoided.


Asunto(s)
Biotina/metabolismo , Volumen de Eritrocitos , Eritrocitos/citología , Eritrocitos/metabolismo , Adolescente , Adulto , Anciano , Humanos , Persona de Mediana Edad , Adulto Joven
12.
Anal Bioanal Chem ; 401(9): 2805-10, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21892638

RESUMEN

Measurement of 3-hydroxyisovaleric acid (3HIA) in human urine has been shown to be a useful indicator of biotin status for a variety of clinical situations, including pregnancy. The work described herein presents a novel UPLC-MS/MS method for accurate and precise quantitation of urinary 3HIA. This method utilizes sample preparation prior to quantitation that has been simplified compared to the previous GC-MS method. To demonstrate the suitability of the UPLC-MS/MS method for human bio-monitoring, this method was used to measure 3-HIA in 64 human urine samples from eight healthy adults in whom marginal biotin deficiency had been induced experimentally by egg white feeding. 3HIA was detected in all specimens; the mean concentration [±standard deviation (SD)] was 80.6 ± 51 µM prior to inducing biotin deficiency. Mean excretion rate for 3HIA (expressed per mol urinary creatinine) before beginning the biotin-deficient diet was 8.5 ± 3.2 mmol 3HIA per mol creatinine and the mean increased threefold with deficiency. These specimens had been previously analyzed by GC-MS; the two data sets showed strong linear relationship with a correlation coefficient of 0.97. These results provide evidence that this method is suitable for bio-monitoring of biotin status in larger populations.


Asunto(s)
Biomarcadores/orina , Biotina/orina , Deficiencia de Biotinidasa/orina , Cromatografía Liquida/métodos , Clara de Huevo/efectos adversos , Espectrometría de Masas en Tándem/métodos , Valeratos/orina , Adulto , Biotina/deficiencia , Deficiencia de Biotinidasa/inducido químicamente , Calibración , Creatinina/orina , Femenino , Humanos , Masculino , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
13.
Transfusion ; 50(12): 2553-64, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20561297

RESUMEN

BACKGROUND: To investigate the pathophysiology of anemia and responses to red blood cell (RBC) transfusions and erythropoietin, repeated measurement of the circulating red blood cell volume (RCV) would be useful. Ovine erythropoiesis is similar to human erythropoiesis. Accordingly, a method for measuring RCV using either human or sheep RBCs labeled at different biotin densities has been previously validated in vitro. Here preclinical studies validating this method for in vivo measurement of circulating RCV in sheep are reported. STUDY DESIGN AND METHODS: For each sheep, autologous RBCs were biotinylated were at four discrete densities (12, 24, 48, and 96µg biotinylation reagent/mL RBCs). The densities were mixed and infused intravenously. Blood was sampled five times over 1 hour beginning at 4 minutes. RCV values were determined based on dilution of each population of biotinylated RBCs and by the [(14) C]cyanate method. RESULTS: There was no difference among RCVs measured at all densities through 16 minutes; however, by 60 minutes, RBCs biotinylated at the highest density overestimated RCV by 7.6%. RCV values increased 41% over the hour, consistent with equilibration with a pool of RBCs sequestered in the spleen. RCV by the [(14) C]cyanate method paralleled results by the biotin method but averaged 8% greater. CONCLUSIONS: These studies provide evidence that all four densities of biotinylated RBCs can be used in sheep to simultaneously and independently determine RCV. We speculate that the multidensity biotinylation method will be useful both for multiple simultaneous measurements and for repeated measurement of circulating RCV and blood volume in humans.


Asunto(s)
Biotina , Biotinilación/métodos , Eritrocitos/citología , Eritrocitos/metabolismo , Coloración y Etiquetado/métodos , Animales , Biotina/química , Biotina/farmacocinética , Tamaño de la Célula , Recuento de Eritrocitos , Eritrocitos/efectos de los fármacos , Femenino , Hematócrito/métodos , Pruebas Hematológicas/métodos , Hemoglobinas/análisis , Humanos , Concentración Osmolar , Ovinos/sangre
14.
Transfusion ; 49(6): 1178-85, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19220818

RESUMEN

BACKGROUND: The development of valid methods for repeatedly measuring red blood cell (RBC) volume (RCV) in the same individual would be useful in furthering understanding of the physiology and pathophysiology of the pregnant woman, fetus, and infant under a variety of conditions. STUDY DESIGN AND METHODS: Small volumes (5 to 100 mL) of either sheep or human blood were used to test the hypothesis that there is no significant difference in RCV and blood volume determined in vitro using as many as five populations of RBCs labeled at distinct biotin densities. By varying the mass of biotinylating reagent, the density of biotin on the surface of RBCs was incrementally increased to produce discrete populations as assessed by flow cytometric enumeration. Calculation of RCV for each biotin-labeled RBC population was based on the dilution principle. RESULTS: All biotin densities, except the most densely labeled, where variance was the greatest, accurately quantitated the in vitro blood volume to within 10 percent of the correct value. There was no bias of either overestimation or underestimation in the determination of the blood volume using either sheep or human RBCs. CONCLUSION: These in vitro results provide evidence that the multidensity biotin labeling method is sufficiently accurate to utilize in vivo for repeated determination of circulating RCV and blood volume.


Asunto(s)
Biotinilación , Volumen de Eritrocitos , Animales , Citometría de Flujo , Humanos , Ovinos
15.
Am J Clin Nutr ; 92(6): 1399-405, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20943794

RESUMEN

BACKGROUND: Blood-based indicators of biotin status in humans were shown to be useful tools in several clinical situations, including pregnancy. We previously validated the activity of the biotin-dependent enzyme propionyl-coenzyme A carboxylase (PCC) in lymphocytes as a sensitive and specific blood-based indicator of marginal degrees of biotin deficiency. However, the measurement of PCC activity in population studies presents substantial analytic challenges. 3-Hydroxyisovaleryl carnitine (3HIA-carnitine) increases in response to the decreased activity of the biotin-dependent enzyme methylcrotonyl-coenzyme A carboxylase and might reflect biotin status. OBJECTIVE: We sought to determine whether the plasma concentration of 3HIA-carnitine increases significantly in marginal biotin deficiency. DESIGN: We experimentally induced marginal, asymptomatic biotin deficiency in 10 healthy adults (8 women) by having the subjects consume undenatured egg white for 28 d; biotin status was then repleted. Plasma concentrations of 3HIA-carnitine were measured on days 0, 14, 28, 35, and 50 by liquid chromatography-mass spectroscopy. RESULTS: The mean plasma 3HIA-carnitine concentration increased with depletion (P < 0.0001) and decreased with repletion (P < 0.0001). Plasma 3HIA-carnitine concentrations were greater than the upper limit of normal concentrations in 7 of 10 subjects by day 14 and in 9 of 10 subjects by day 28 and decreased to within normal limits in 9 of 10 subjects by day 50. CONCLUSIONS: These studies provide evidence that 3HIA-carnitine is an early and sensitive indicator of marginal biotin deficiency. The ease of sample collection, small sample volume requirement, and stability of 3HIA-carnitine during storage suggest that plasma 3HIA-carnitine concentration is likely to be a useful indicator of marginal biotin deficiency for larger population studies.


Asunto(s)
Biotina/deficiencia , Carnitina/sangre , Adulto , Anciano , Biomarcadores/sangre , Biotina/sangre , Ligasas de Carbono-Carbono/metabolismo , Carnitina/análogos & derivados , Enfermedades Carenciales/diagnóstico , Clara de Huevo , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA